  "document": {
    "parse_profiles": [
      {
        "sheet": "2 - Main",
        "columns": {
          "qty": "I"
        },
        "source": "arithmetic",
        "note": "Quantity read from \"TOTAL QTY\" — identified arithmetically: qty × rate = amount on 6370/6371 rated rows."
      },
      {
        "sheet": "3 - Ext",
        "columns": {
          "qty": "I"
        },
        "source": "arithmetic",
        "note": "Quantity read from \"TOTAL QTY\" — identified arithmetically: qty × rate = amount on 462/462 rated rows."
      }
    ],
    "bill_no": "EMR ZFD AZR MW 0177 BOQ (OCT 2024) PTA456 — 9 sheets",
    "bill_title": "EMR ZFD AZR MW 0177 BOQ (OCT 2024) PTA456 — 9 sheets",
    "project_ref": "ADDRESS RESIDENCES ZABEEL",
    "currency": "AED",
    "carried_to_summary_aed": 0,
    "declared_summary": {
      "sheets": [
        "1 Sum",
        "4 Sum",
        " Summary"
      ],
      "zones": [
        "BASEMENT",
        "GF & PODIUM",
        "TOWER 1",
        "TOWER 2",
        "TOWER 3",
        "TOWER 4",
        "EXTERNAL WORKS"
      ],
      "bills": [
        {
          "sheet": "1 Sum",
          "ref": null,
          "label": "1 Sum",
          "sections": [
            {
              "sheet": "1 Sum",
              "row": 6,
              "label": "GENERAL REQUIREMENTS FOR THE WHOLE OF THE WORK",
              "page_range": "1/GR/1 - 1/GR/15",
              "ref": {
                "bill": "1",
                "section": "GR",
                "first": 1,
                "last": 15
              },
              "section_ref": "1/GR",
              "total": 313190338.5787259,
              "total_printed": "",
              "zones": []
            }
          ],
          "subtotal": {
            "label": "TO MAIN SUMMARY AED",
            "total": 313190338.5787259,
            "zones": [],
            "row": 51
          }
        },
        {
          "sheet": "4 Sum",
          "ref": null,
          "label": "4 Sum",
          "sections": [
            {
              "sheet": "4 Sum",
              "row": 6,
              "label": "PROVISIONAL SUMS",
              "page_range": "4/PS/1",
              "ref": {
                "bill": "4",
                "section": "PS",
                "first": 1,
                "last": 1
              },
              "section_ref": "4/PS",
              "total": 5720000,
              "total_printed": "",
              "zones": []
            }
          ],
          "subtotal": {
            "label": "TO MAIN SUMMARY AED",
            "total": 5720000,
            "zones": [],
            "row": 53
          }
        },
        {
          "sheet": " Summary",
          "ref": "1",
          "label": "BILL NO. 1 -GENERAL REQUIREMENTS",
          "sections": [],
          "entry": {
            "sheet": " Summary",
            "row": 11,
            "label": "BILL NO. 1 -GENERAL REQUIREMENTS",
            "page_range": "Page 1/GR/1 - 1/GR/15",
            "ref": {
              "bill": "1",
              "section": "GR",
              "first": 1,
              "last": 15
            },
            "section_ref": "1/GR",
            "total": 313190338.5787259,
            "total_printed": "",
            "zones": [
              30341654.894374996,
              49154297.84561334,
              53420463.35289062,
              62321623.79951561,
              59861639.437240615,
              58090659.24909062,
              0
            ]
          }
        },
        {
          "sheet": " Summary",
          "ref": "2",
          "label": "BILL NO. 2 - MAIN WORKS",
          "sections": [
            {
              "sheet": " Summary",
              "row": 15,
              "label": "SECTION B - SITE WORKS",
              "page_range": "Page 2/B/1 - 2/B/4",
              "ref": {
                "bill": "2",
                "section": "B",
                "first": 1,
                "last": 4
              },
              "section_ref": "2/B",
              "total": 3273846,
              "total_printed": "",
              "zones": [
                3089406,
                184440,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 17,
              "label": "SECTION C - CONCRETE WORKS",
              "page_range": "Page 2/C/1 - 2/C/12",
              "ref": {
                "bill": "2",
                "section": "C",
                "first": 1,
                "last": 12
              },
              "section_ref": "2/C",
              "total": 495971852,
              "total_printed": "",
              "zones": [
                132562830,
                88523994,
                59773765,
                75017131,
                70612484,
                69481648,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 19,
              "label": "SECTION D - MASONRY",
              "page_range": "Page 2/D/1 - 2/D/4",
              "ref": {
                "bill": "2",
                "section": "D",
                "first": 1,
                "last": 4
              },
              "section_ref": "2/D",
              "total": 37136250,
              "total_printed": "",
              "zones": [
                702720,
                4079240,
                7428790,
                8377580,
                8457140,
                8090780,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 21,
              "label": "SECTION E - METALWORK",
              "page_range": "Page 2/E/1 - 2/E/12",
              "ref": {
                "bill": "2",
                "section": "E",
                "first": 1,
                "last": 12
              },
              "section_ref": "2/E",
              "total": 275148885.81,
              "total_printed": "",
              "zones": [
                2203590,
                17421693.78,
                58338442.83,
                68011074.5,
                65496406.199999996,
                63677678.5,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 23,
              "label": "SECTION F - WOOD WORK",
              "page_range": "Page 2/F/1 - 2/F/25",
              "ref": {
                "bill": "2",
                "section": "F",
                "first": 1,
                "last": 25
              },
              "section_ref": "2/F",
              "total": 121816160.6275,
              "total_printed": "",
              "zones": [
                16660,
                4921515.2,
                26786924.680625,
                30687542.245625,
                30442965.680625,
                28960552.820625,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 25,
              "label": "SECTION G - THERMAL AND MOISTURE PROTECTION",
              "page_range": "Page 2/G/1 - 2/G/5",
              "ref": {
                "bill": "2",
                "section": "G",
                "first": 1,
                "last": 5
              },
              "section_ref": "2/G",
              "total": 34771095.59,
              "total_printed": "",
              "zones": [
                7355261,
                3947471,
                5396237,
                6233365,
                6049288.59,
                5789473,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 27,
              "label": "SECTION H - DOORS AND WINDOWS",
              "page_range": "Page 2/H/1 - 2/H/17",
              "ref": {
                "bill": "2",
                "section": "H",
                "first": 1,
                "last": 17
              },
              "section_ref": "2/H",
              "total": 196718639,
              "total_printed": "",
              "zones": [
                1446840,
                18637831,
                40094224,
                48073838,
                44767311,
                43698595,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 29,
              "label": "SECTION J - FINISHES",
              "page_range": "Page 2/J/1 - 2/J/18",
              "ref": {
                "bill": "2",
                "section": "J",
                "first": 1,
                "last": 18
              },
              "section_ref": "2/J",
              "total": 288882679.495,
              "total_printed": "",
              "zones": [
                17984104.575,
                24416970.73,
                56369829.8,
                65950329.4,
                63519139.69,
                60642305.3,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 31,
              "label": "SECTION K - ACCESSORIES",
              "page_range": "Page 2/K/1 - 2/K/14",
              "ref": {
                "bill": "2",
                "section": "K",
                "first": 1,
                "last": 14
              },
              "section_ref": "2/K",
              "total": 47588636.18,
              "total_printed": "",
              "zones": [
                1159366,
                4482475.62,
                9784029.69,
                11116834.120000001,
                10687817.4,
                10358113.35,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 33,
              "label": "SECTION L - EQUIPMENT",
              "page_range": "Page 2/L/1 - 2/L/7",
              "ref": {
                "bill": "2",
                "section": "L",
                "first": 1,
                "last": 7
              },
              "section_ref": "2/L",
              "total": 36405009.13,
              "total_printed": "",
              "zones": [
                0,
                1452481.8900000001,
                8545913.98,
                8570893.2,
                9265772.3,
                8569947.76,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 35,
              "label": "SECTION M - FURNISHING",
              "page_range": "Page 2/M/1 - 2/M/7",
              "ref": {
                "bill": "2",
                "section": "M",
                "first": 1,
                "last": 7
              },
              "section_ref": "2/M",
              "total": 324125,
              "total_printed": "",
              "zones": [
                0,
                324125,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 37,
              "label": "SECTION P - CONVEYING SYSTEMS",
              "page_range": "Page 2/P/1 - 2/P/8",
              "ref": {
                "bill": "2",
                "section": "P",
                "first": 1,
                "last": 8
              },
              "section_ref": "2/P",
              "total": 52467224,
              "total_printed": "",
              "zones": [
                0,
                0,
                13116806,
                13116806,
                13116806,
                13116806,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 39,
              "label": "SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS",
              "page_range": "Page 2/Q/1 - 2/Q/190",
              "ref": {
                "bill": "2",
                "section": "Q",
                "first": 1,
                "last": 190
              },
              "section_ref": "2/Q",
              "total": 249115911.07999998,
              "total_printed": "",
              "zones": [
                25152775.8,
                45966514.86,
                43220094.379999995,
                46215832.32,
                44674810.53,
                43885883.19,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 41,
              "label": "SECTION R - ELECTRICAL INSTALLATIONS",
              "page_range": "Page 2/R/1 - 2/R/177",
              "ref": {
                "bill": "2",
                "section": "R",
                "first": 1,
                "last": 177
              },
              "section_ref": "2/R",
              "total": 249590682.1209541,
              "total_printed": "",
              "zones": [
                17179239,
                58956666.12095409,
                38436880,
                47137064,
                44695684,
                43185149,
                null
              ]
            }
          ],
          "subtotal": {
            "label": "BILL. NO.2 SUB-TOTAL AMOUNT",
            "total": 2089210996.0334542,
            "zones": [
              208852792.375,
              273315419.2009541,
              367291937.360625,
              428508289.785625,
              411785625.390625,
              399456931.92062503,
              null
            ],
            "row": 43
          }
        },
        {
          "sheet": " Summary",
          "ref": "3",
          "label": "BILL NO. 3 -EXTERNAL WORKS",
          "sections": [
            {
              "sheet": " Summary",
              "row": 47,
              "label": "SECTION B - SITE WORKS",
              "page_range": "Page 3/B/1 - 3/B/6",
              "ref": {
                "bill": "3",
                "section": "B",
                "first": 1,
                "last": 6
              },
              "section_ref": "3/B",
              "total": 14715046,
              "total_printed": "",
              "zones": [
                350000,
                14279154,
                22326,
                20620,
                22326,
                20620,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 49,
              "label": "SECTION C - CONCRETE WORKS",
              "page_range": "Page 3/C/1 - 3/C/4",
              "ref": {
                "bill": "3",
                "section": "C",
                "first": 1,
                "last": 4
              },
              "section_ref": "3/C",
              "total": 13034525,
              "total_printed": "",
              "zones": [
                0,
                11961805,
                270250,
                266110,
                270250,
                266110,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 51,
              "label": "SECTION E - METALWORK",
              "page_range": "Page 3/E/1 - 3/E/3",
              "ref": {
                "bill": "3",
                "section": "E",
                "first": 1,
                "last": 3
              },
              "section_ref": "3/E",
              "total": 337040,
              "total_printed": "",
              "zones": [
                0,
                279640,
                10600,
                18100,
                10600,
                18100,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 53,
              "label": "SECTION G - THERMAL AND MOISTURE PROTECTION",
              "page_range": "Page 3/G/1 - 3/G/3",
              "ref": {
                "bill": "3",
                "section": "G",
                "first": 1,
                "last": 3
              },
              "section_ref": "3/G",
              "total": 19849160.120000005,
              "total_printed": "",
              "zones": [
                0,
                18796717,
                272060.28,
                256218.28,
                272060.28,
                252104.28,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 55,
              "label": "SECTION J - FINISHES",
              "page_range": "Page 3/J/1 - 3/J/9",
              "ref": {
                "bill": "3",
                "section": "J",
                "first": 1,
                "last": 9
              },
              "section_ref": "3/J",
              "total": 4969106.78,
              "total_printed": "",
              "zones": [
                0,
                4181212.7800000003,
                166335,
                228547,
                166335,
                226677,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 57,
              "label": "SECTION K - ACCESSORIES",
              "page_range": "Page 3/K/1 - 3/K/3",
              "ref": {
                "bill": "3",
                "section": "K",
                "first": 1,
                "last": 3
              },
              "section_ref": "3/K",
              "total": 173500,
              "total_printed": "",
              "zones": [
                0,
                173500,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 59,
              "label": "SECTION L - EQUIPMENT",
              "page_range": "Page 3/L/1 - 3/L/3",
              "ref": {
                "bill": "3",
                "section": "L",
                "first": 1,
                "last": 3
              },
              "section_ref": "3/L",
              "total": 2205000,
              "total_printed": "",
              "zones": [
                0,
                2205000,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 61,
              "label": "SECTION M - FURNISHING",
              "page_range": "Page 3/M/1 - 3/M/3",
              "ref": {
                "bill": "3",
                "section": "M",
                "first": 1,
                "last": 3
              },
              "section_ref": "3/M",
              "total": 7299960,
              "total_printed": "",
              "zones": [
                0,
                7299960,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 63,
              "label": "SECTION N - SPECIAL CONSTRUCTION",
              "page_range": "Page 3/N/1 - 3/N/10",
              "ref": {
                "bill": "3",
                "section": "N",
                "first": 1,
                "last": 10
              },
              "section_ref": "3/N",
              "total": 4294078,
              "total_printed": "",
              "zones": [
                0,
                2886725,
                311696,
                399268,
                311696,
                384693,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 65,
              "label": "SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS",
              "page_range": "Page 3/Q/1 - 3/Q/10",
              "ref": {
                "bill": "3",
                "section": "Q",
                "first": 1,
                "last": 10
              },
              "section_ref": "3/Q",
              "total": 1947274.35,
              "total_printed": "",
              "zones": [
                0,
                1947274.35,
                0,
                0,
                0,
                0,
                null
              ]
            },
            {
              "sheet": " Summary",
              "row": 67,
              "label": "SECTION R - ELECTRICAL INSTALLATIONS",
              "page_range": "Page 3/R/1 - 3/R/6",
              "ref": {
                "bill": "3",
                "section": "R",
                "first": 1,
                "last": 6
              },
              "section_ref": "3/R",
              "total": 1897683.225,
              "total_printed": "",
              "zones": [
                50000,
                1668750.225,
                71784,
                107149,
                0,
                0,
                null
              ]
            }
          ],
          "subtotal": {
            "label": "BILL. NO.3 SUB-TOTAL AMOUNT",
            "total": 70722373.475,
            "zones": [
              400000,
              65679738.355000004,
              1125051.28,
              1296012.28,
              1053267.28,
              1168304.28,
              null
            ],
            "row": 69
          }
        },
        {
          "sheet": " Summary",
          "ref": "4",
          "label": "BILL NO. 4 -PROVISIONAL SUMS",
          "sections": [],
          "entry": {
            "sheet": " Summary",
            "row": 71,
            "label": "BILL NO. 4 -PROVISIONAL SUMS",
            "page_range": null,
            "total": 5720000,
            "total_printed": "",
            "zones": [
              null,
              null,
              null,
              5720000,
              null,
              null,
              null
            ]
          }
        }
      ],
      "totals": {
        "grand": {
          "label": "TOTAL AMOUNT",
          "total": 2478843708.08718,
          "zones": [
            239594447.269375,
            388149455.40156746,
            421837451.9935156,
            497845925.86514056,
            472700532.1078656,
            458715895.4497156,
            0
          ],
          "row": 74
        },
        "tender": {
          "label": "TOTAL TENDER SUM CARRIED TO FORM OF TENDER",
          "total": null,
          "row": 80
        },
        "in_words": {
          "text": "United Arab Emirates dirham",
          "row": 81,
          "matches": null
        }
      },
      "self_check": [
        {
          "ok": true,
          "detail": "1 Sum: its 1 entries add to 313190338.58, and it declares 313190338.58"
        },
        {
          "ok": true,
          "detail": "4 Sum: its 1 entries add to 5720000.00, and it declares 5720000.00"
        },
        {
          "ok": true,
          "detail": "BILL NO. 2 - MAIN WORKS: its 14 entries add to 2089210996.03, and it declares 2089210996.03"
        },
        {
          "ok": true,
          "detail": "BILL NO. 3 -EXTERNAL WORKS: its 11 entries add to 70722373.47, and it declares 70722373.47"
        },
        {
          "ok": true,
          "detail": "the bills add to 2478843708.09, and TOTAL AMOUNT declares 2478843708.09"
        }
      ],
      "strays": [
        " Summary row 74: stray 26064.689999999944 beside “TOTAL AMOUNT”",
        " Summary row 74: stray 28993484.57707391 beside “TOTAL AMOUNT”",
        " Summary row 84: stray 1113.574620300764 beside “….......................................”",
        " Summary row 84: stray 1112.3663691021827 beside “….......................................”",
        " Summary row 86: stray 2479341709 beside “….......................................”"
      ]
    },
    "section_titles": {
      "2/B": "SITE WORK",
      "2/C": "CONCRETE WORK",
      "2/D": "MASONRY",
      "2/E": "METALWORK",
      "2/F": "WOODWORK",
      "2/G": "THERMAL AND MOISTURE PROTECTION",
      "2/H": "DOORS AND WINDOWS",
      "2/J": "FINISHES",
      "2/K": "WASTE MANAGEMENT SYSTEM",
      "2/L": "EQUIPMENT",
      "2/M": "FURNISHINGS",
      "2/P": "CONVEYING SYSTEMS",
      "2/Q": "MECHANICAL ENGINEERING INSTALLATIONS",
      "2/R": "ELECTRICAL ENGINEERING INSTALLATIONS",
      "3/B": "SITE WORK",
      "3/C": "CONCRETE WORK",
      "3/E": "METALWORK",
      "3/G": "THERMAL AND MOISTURE PROTECTION",
      "3/K": "ACCESSORIES",
      "3/M": "FURNISHINGS",
      "3/N": "SPECIAL CONSTRUCTION",
      "3/Q": "MECHANICAL ENGINEERING INSTALLATIONS"
    },
    "source_collection_page": {
      "GR1/1": 313190338.5787259,
      "GR1/2": 0,
      "GR1/3": 0,
      "GR1/4": 0,
      "GR1/5": 0,
      "GR1/6": 0,
      "GR1/7": 0,
      "GR1/8": 0,
      "GR1/9": 0,
      "GR1/10": 0,
      "GR1/11": 0,
      "GR1/12": 0,
      "GR1/13": 0,
      "GR1/14": 0,
      "GR1/15": 0,
      "2 - Main/1": 1528566,
      "2 - Main/2": 1745280,
      "2 - Main/3": 0,
      "2 - Main/4": 18015000,
      "2 - Main/5": 38937000,
      "2 - Main/6": 48192600,
      "2 - Main/7": 455700,
      "2 - Main/8": 201742608,
      "2 - Main/9": 1294933,
      "2 - Main/10": 78131625,
      "2 - Main/11": 1865920,
      "2 - Main/12": 104349826,
      "2 - Main/13": 2986640,
      "2 - Main/14": 0,
      "2 - Main/15": 37136250,
      "2 - Main/16": 0,
      "2 - Main/17": 0,
      "2 - Main/18": 2664900,
      "2 - Main/19": 1736100,
      "2 - Main/20": 97474280,
      "2 - Main/21": 7698304.88,
      "2 - Main/22": 55242074.74,
      "2 - Main/23": 46637835.480000004,
      "2 - Main/24": 53452110.71,
      "2 - Main/25": 5762220,
      "2 - Main/26": 486770,
      "2 - Main/27": 3994290,
      "2 - Main/28": 0,
      "2 - Main/29": 3223025,
      "2 - Main/30": 1725175,
      "2 - Main/31": 737912.5,
      "2 - Main/32": 4045325,
      "2 - Main/33": 1862337.5,
      "2 - Main/34": 3770862.5,
      "2 - Main/35": 2867356,
      "2 - Main/36": 2058002,
      "2 - Main/37": 21341525,
      "2 - Main/38": 15432625,
      "2 - Main/39": 1554945,
      "2 - Main/40": 20338080,
      "2 - Main/41": 28454535,
      "2 - Main/42": 6959340,
      "2 - Main/43": 1196970,
      "2 - Main/44": 526808.7224999999,
      "2 - Main/45": 1348175.205,
      "2 - Main/46": 59190,
      "2 - Main/47": 217100,
      "2 - Main/48": 351001.2,
      "2 - Main/49": 1457360,
      "2 - Main/50": 1526080,
      "2 - Main/51": 762430,
      "2 - Main/52": 0,
      "2 - Main/53": 16074270.66,
      "2 - Main/54": 4575633,
      "2 - Main/55": 14121191.93,
      "2 - Main/56": 0,
      "2 - Main/57": 34807871,
      "2 - Main/58": 6467176,
      "2 - Main/59": 9467420,
      "2 - Main/60": 1765530,
      "2 - Main/61": 1660330,
      "2 - Main/62": 223330,
      "2 - Main/63": 1234650,
      "2 - Main/64": 83332190,
      "2 - Main/65": 2595930,
      "2 - Main/66": 12146200,
      "2 - Main/67": 1414780,
      "2 - Main/68": 34480750,
      "2 - Main/69": 5531370,
      "2 - Main/70": 1395312,
      "2 - Main/71": 195800,
      "2 - Main/72": 0,
      "2 - Main/73": 37474583.232,
      "2 - Main/74": 3658864.8200000003,
      "2 - Main/75": 131853537.53,
      "2 - Main/76": 2895974.5,
      "2 - Main/77": 1057887,
      "2 - Main/78": 16486093.08,
      "2 - Main/79": 19878765.68,
      "2 - Main/80": 15269702.059999999,
      "2 - Main/81": 1904158.605,
      "2 - Main/82": 1706965,
      "2 - Main/83": 10253430.62,
      "2 - Main/84": 5380804.4,
      "2 - Main/85": 2317366.1,
      "2 - Main/86": 21128077.018,
      "2 - Main/87": 15921959.85,
      "2 - Main/88": 1694510,
      "2 - Main/89": 0,
      "2 - Main/90": 116340.14,
      "2 - Main/91": 3593625.04,
      "2 - Main/92": 1006438.04,
      "2 - Main/93": 1971170,
      "2 - Main/94": 2274534.5,
      "2 - Main/95": 1144474.03,
      "2 - Main/96": 621910,
      "2 - Main/97": 19434546.95,
      "2 - Main/98": 6064629.98,
      "2 - Main/99": 2825712.5,
      "2 - Main/100": 5972835,
      "2 - Main/101": 2562420,
      "2 - Main/102": 0,
      "2 - Main/103": 24242209.13,
      "2 - Main/104": 0,
      "2 - Main/105": 10366000,
      "2 - Main/106": 1671800,
      "2 - Main/107": 125000,
      "2 - Main/108": 0,
      "2 - Main/109": 0,
      "2 - Main/110": 0,
      "2 - Main/111": 0,
      "2 - Main/112": 0,
      "2 - Main/113": 324125,
      "2 - Main/114": 0,
      "2 - Main/115": 425624,
      "2 - Main/116": 22441600,
      "2 - Main/117": 25900000,
      "2 - Main/118": 3700000,
      "2 - Main/119": 0,
      "2 - Main/120": 0,
      "2 - Main/121": 0,
      "2 - Main/122": 1884867.45,
      "2 - Main/123": 9367476.55,
      "2 - Main/124": 2048385.6500000001,
      "2 - Main/125": 1884711.23,
      "2 - Main/126": 0,
      "2 - Main/127": 9485313.8,
      "2 - Main/128": 2260215.4,
      "2 - Main/129": 1416861,
      "2 - Main/130": 1319696,
      "2 - Main/131": 17135700,
      "2 - Main/132": 4801993,
      "2 - Main/133": 1214678,
      "2 - Main/134": 43470,
      "2 - Main/135": 45500,
      "2 - Main/136": 144000,
      "2 - Main/137": 26000,
      "2 - Main/138": 10734885,
      "2 - Main/139": 2052310,
      "2 - Main/140": 2298635,
      "2 - Main/141": 641325,
      "2 - Main/142": 172985,
      "2 - Main/143": 2870070,
      "2 - Main/144": 2673050,
      "2 - Main/145": 579000,
      "2 - Main/146": 139200,
      "2 - Main/147": 25000,
      "2 - Main/148": 9159495,
      "2 - Main/149": 14462195,
      "2 - Main/150": 4758180,
      "2 - Main/151": 2037230,
      "2 - Main/152": 6716400,
      "2 - Main/153": 1718000,
      "2 - Main/154": 663400,
      "2 - Main/155": 2964600,
      "2 - Main/156": 131000,
      "2 - Main/157": 18712210,
      "2 - Main/158": 3561309,
      "2 - Main/159": 1277319.8,
      "2 - Main/160": 8433075,
      "2 - Main/161": 1974355,
      "2 - Main/162": 3227448,
      "2 - Main/163": 396000,
      "2 - Main/164": 12179485,
      "2 - Main/165": 101310,
      "2 - Main/166": 134775,
      "2 - Main/167": 597816,
      "2 - Main/168": 280686,
      "2 - Main/169": 119010,
      "2 - Main/170": 472370,
      "2 - Main/171": 59350,
      "2 - Main/172": 167595,
      "2 - Main/173": 456850,
      "2 - Main/174": 44230,
      "2 - Main/175": 678630,
      "2 - Main/176": 761850,
      "2 - Main/177": 704990,
      "2 - Main/178": 535065,
      "2 - Main/179": 86920,
      "2 - Main/180": 102220,
      "2 - Main/181": 66940,
      "2 - Main/182": 76830,
      "2 - Main/183": 72090,
      "2 - Main/184": 672170,
      "2 - Main/185": 1440480,
      "2 - Main/186": 361400,
      "2 - Main/187": 67150,
      "2 - Main/188": 62640,
      "2 - Main/189": 63750,
      "2 - Main/190": 825630,
      "2 - Main/191": 980600,
      "2 - Main/192": 65740,
      "2 - Main/193": 250900,
      "2 - Main/194": 200200,
      "2 - Main/195": 86540,
      "2 - Main/196": 154890,
      "2 - Main/197": 63200,
      "2 - Main/198": 74390,
      "2 - Main/199": 86140,
      "2 - Main/200": 89970,
      "2 - Main/201": 1306480,
      "2 - Main/202": 1280720,
      "2 - Main/203": 62870,
      "2 - Main/204": 62870,
      "2 - Main/205": 68590,
      "2 - Main/206": 71830,
      "2 - Main/207": 960320,
      "2 - Main/208": 632170,
      "2 - Main/209": 62550,
      "2 - Main/210": 57260,
      "2 - Main/211": 77080,
      "2 - Main/212": 79470,
      "2 - Main/213": 67580,
      "2 - Main/214": 61880,
      "2 - Main/215": 70990,
      "2 - Main/216": 70030,
      "2 - Main/217": 79230,
      "2 - Main/218": 77260,
      "2 - Main/219": 86060,
      "2 - Main/220": 93220,
      "2 - Main/221": 421340.0000000001,
      "2 - Main/222": 87690,
      "2 - Main/223": 62870,
      "2 - Main/224": 67250,
      "2 - Main/225": 91200,
      "2 - Main/226": 64400,
      "2 - Main/227": 1283160,
      "2 - Main/228": 1082840,
      "2 - Main/229": 63650,
      "2 - Main/230": 56710,
      "2 - Main/231": 64080,
      "2 - Main/232": 54320,
      "2 - Main/233": 1021950,
      "2 - Main/234": 1458670,
      "2 - Main/235": 111060,
      "2 - Main/236": 57260,
      "2 - Main/237": 69470,
      "2 - Main/238": 66140,
      "2 - Main/239": 104370,
      "2 - Main/240": 70780,
      "2 - Main/241": 79130,
      "2 - Main/242": 76050,
      "2 - Main/243": 82150,
      "2 - Main/244": 69360,
      "2 - Main/245": 658670,
      "2 - Main/246": 1543200,
      "2 - Main/247": 453590,
      "2 - Main/248": 329180,
      "2 - Main/249": 51460,
      "2 - Main/250": 73970,
      "2 - Main/251": 429810,
      "2 - Main/252": 917920,
      "2 - Main/253": 176450,
      "2 - Main/254": 57040,
      "2 - Main/255": 78030,
      "2 - Main/256": 68450,
      "2 - Main/257": 75190,
      "2 - Main/258": 82410,
      "2 - Main/259": 76740,
      "2 - Main/260": 1295430,
      "2 - Main/261": 11237970,
      "2 - Main/262": 190965,
      "2 - Main/263": 29640,
      "2 - Main/264": 32430,
      "2 - Main/265": 25455,
      "2 - Main/266": 113526,
      "2 - Main/267": 27538,
      "2 - Main/268": 25074,
      "2 - Main/269": 26376,
      "2 - Main/270": 19482,
      "2 - Main/271": 108090,
      "2 - Main/272": 48612,
      "2 - Main/273": 5595,
      "2 - Main/274": 14000,
      "2 - Main/275": 40000,
      "2 - Main/276": 12799020,
      "2 - Main/277": 478450,
      "2 - Main/278": 108122,
      "2 - Main/279": 131642,
      "2 - Main/280": 147756,
      "2 - Main/281": 502480,
      "2 - Main/282": 136816,
      "2 - Main/283": 758870,
      "2 - Main/284": 1259500,
      "2 - Main/285": 1288000,
      "2 - Main/286": 291000,
      "2 - Main/287": 207000,
      "2 - Main/288": 490000,
      "2 - Main/289": 315000,
      "2 - Main/290": 140000,
      "2 - Main/291": 1093200,
      "2 - Main/292": 1623181,
      "2 - Main/293": 7172328,
      "2 - Main/294": 25000,
      "2 - Main/295": 11139546.200000001,
      "2 - Main/296": 0,
      "2 - Main/297": 0,
      "2 - Main/298": 0,
      "2 - Main/299": 0,
      "2 - Main/300": 61086,
      "2 - Main/301": 114880,
      "2 - Main/302": 139000,
      "2 - Main/303": 417925,
      "2 - Main/304": 661745,
      "2 - Main/305": 182540,
      "2 - Main/306": 269820,
      "2 - Main/307": 675020,
      "2 - Main/308": 404256,
      "2 - Main/309": 15104,
      "2 - Main/310": 35122,
      "2 - Main/311": 99420,
      "2 - Main/312": 110600,
      "2 - Main/313": 73360,
      "2 - Main/314": 92880,
      "2 - Main/315": 61280,
      "2 - Main/316": 119760,
      "2 - Main/317": 399600,
      "2 - Main/318": 94640,
      "2 - Main/319": 213760,
      "2 - Main/320": 290080,
      "2 - Main/321": 346560,
      "2 - Main/322": 239760,
      "2 - Main/323": 156480,
      "2 - Main/324": 288080,
      "2 - Main/325": 132880,
      "2 - Main/326": 368400,
      "2 - Main/327": 153440,
      "2 - Main/328": 202720,
      "2 - Main/329": 359840,
      "2 - Main/330": 133760,
      "2 - Main/331": 329840,
      "2 - Main/332": 250400,
      "2 - Main/333": 318880,
      "2 - Main/334": 190810,
      "2 - Main/335": 147810,
      "2 - Main/336": 119170,
      "2 - Main/337": 203060,
      "2 - Main/338": 194210,
      "2 - Main/339": 150930,
      "2 - Main/340": 127530,
      "2 - Main/341": 197180,
      "2 - Main/342": 159680,
      "2 - Main/343": 231420,
      "2 - Main/344": 214625,
      "2 - Main/345": 569495,
      "2 - Main/346": 227200,
      "2 - Main/347": 542685,
      "2 - Main/348": 40380,
      "2 - Main/349": 30540,
      "2 - Main/350": 35940,
      "2 - Main/351": 71270,
      "2 - Main/352": 66880,
      "2 - Main/353": 99845,
      "2 - Main/354": 123595,
      "2 - Main/355": 120460,
      "2 - Main/356": 85950,
      "2 - Main/357": 204010,
      "2 - Main/358": 143840,
      "2 - Main/359": 141600,
      "2 - Main/360": 542120,
      "2 - Main/361": 997950,
      "2 - Main/362": 1348525,
      "2 - Main/363": 6280390,
      "2 - Main/364": 3044000,
      "2 - Main/365": 105000,
      "2 - Main/366": 85000,
      "2 - Main/367": 85000,
      "2 - Main/368": 80000,
      "2 - Main/369": 80000,
      "2 - Main/370": 90000,
      "2 - Main/371": 510300,
      "2 - Main/372": 13253400,
      "2 - Main/373": 10414127,
      "2 - Main/374": 1945653,
      "2 - Main/375": 273900,
      "2 - Main/376": 272150,
      "2 - Main/377": 312350,
      "2 - Main/378": 274550,
      "2 - Main/379": 249750,
      "2 - Main/380": 246300,
      "2 - Main/381": 248000,
      "2 - Main/382": 268900,
      "2 - Main/383": 367200,
      "2 - Main/384": 272800,
      "2 - Main/385": 272800,
      "2 - Main/386": 316220,
      "2 - Main/387": 471600,
      "2 - Main/388": 485100,
      "2 - Main/389": 517125,
      "2 - Main/390": 189000,
      "2 - Main/391": 57750,
      "2 - Main/392": 553875,
      "2 - Main/393": 498750,
      "2 - Main/394": 73500,
      "2 - Main/395": 57750,
      "2 - Main/396": 133875,
      "2 - Main/397": 598500,
      "2 - Main/398": 506625,
      "2 - Main/399": 57750,
      "2 - Main/400": 68250,
      "2 - Main/401": 493500,
      "2 - Main/402": 546000,
      "2 - Main/403": 65625,
      "2 - Main/404": 60375,
      "2 - Main/405": 63525,
      "2 - Main/406": 69300,
      "2 - Main/407": 69300,
      "2 - Main/408": 75600,
      "2 - Main/409": 69300,
      "2 - Main/410": 133350,
      "2 - Main/411": 724850,
      "2 - Main/412": 795900,
      "2 - Main/413": 1176000,
      "2 - Main/414": 4049580,
      "2 - Main/415": 208280,
      "2 - Main/416": 1875300,
      "2 - Main/417": 2380515,
      "2 - Main/418": 5969723,
      "2 - Main/419": 8870850,
      "2 - Main/420": 2093910,
      "2 - Main/421": 3014405,
      "2 - Main/422": 826380,
      "2 - Main/423": 38339470,
      "2 - Main/424": 2599238,
      "2 - Main/425": 863480,
      "2 - Main/426": 4442392,
      "2 - Main/427": 12205525,
      "2 - Main/428": 4846576,
      "2 - Main/429": 69300,
      "2 - Main/430": 69300,
      "2 - Main/431": 69300,
      "2 - Main/432": 72450,
      "2 - Main/433": 69300,
      "2 - Main/434": 69300,
      "2 - Main/435": 69300,
      "2 - Main/436": 69300,
      "2 - Main/437": 69300,
      "2 - Main/438": 2054650,
      "2 - Main/439": 2645632,
      "2 - Main/440": 137760,
      "2 - Main/441": 6370580,
      "2 - Main/442": 1357280,
      "2 - Main/443": 2508310,
      "2 - Main/444": 700120,
      "2 - Main/445": 3899580,
      "2 - Main/446": 1194700,
      "2 - Main/447": 8339580,
      "2 - Main/448": 1972960,
      "2 - Main/449": 1851980,
      "2 - Main/450": 3708395,
      "2 - Main/451": 6899321,
      "2 - Main/452": 2309365,
      "2 - Main/453": 962520,
      "2 - Main/454": 240115,
      "2 - Main/455": 1211115,
      "2 - Main/456": 7771900,
      "2 - Main/457": 4684540,
      "2 - Main/458": 3400450,
      "2 - Main/459": 604250,
      "2 - Main/460": 1723465,
      "2 - Main/461": 15750,
      "2 - Main/462": 14848720,
      "2 - Main/463": 0,
      "2 - Main/464": 0,
      "2 - Main/465": 11884550.25,
      "2 - Main/466": 0,
      "2 - Main/467": 0,
      "2 - Main/468": 0,
      "3 - Ext/1": 6850450,
      "3 - Ext/2": 1718720,
      "3 - Ext/3": 3907496,
      "3 - Ext/4": 2238380,
      "3 - Ext/5": 0,
      "3 - Ext/6": 4464940,
      "3 - Ext/7": 7903335,
      "3 - Ext/8": 666250,
      "3 - Ext/9": 337040,
      "3 - Ext/10": 0,
      "3 - Ext/11": 19849160.12,
      "3 - Ext/12": 0,
      "3 - Ext/13": 2466691.7800000003,
      "3 - Ext/14": 637745,
      "3 - Ext/15": 792650,
      "3 - Ext/16": 316300,
      "3 - Ext/17": 128582,
      "3 - Ext/18": 445300,
      "3 - Ext/19": 181838,
      "3 - Ext/20": 0,
      "3 - Ext/21": 173500,
      "3 - Ext/22": 0,
      "3 - Ext/23": 2205000,
      "3 - Ext/24": 0,
      "3 - Ext/25": 4054050,
      "3 - Ext/26": 3245910,
      "3 - Ext/27": 598170,
      "3 - Ext/28": 1229669,
      "3 - Ext/29": 90915,
      "3 - Ext/30": 213577,
      "3 - Ext/31": 564921,
      "3 - Ext/32": 283099,
      "3 - Ext/33": 514707,
      "3 - Ext/34": 799020,
      "3 - Ext/35": 0,
      "3 - Ext/36": 18570,
      "3 - Ext/37": 190130,
      "3 - Ext/38": 252440,
      "3 - Ext/39": 565907,
      "3 - Ext/40": 293480,
      "3 - Ext/41": 221980,
      "3 - Ext/42": 312040,
      "3 - Ext/43": 92727.35,
      "3 - Ext/44": 0,
      "3 - Ext/45": 32918,
      "3 - Ext/46": 417150,
      "3 - Ext/47": 1447615.225,
      "3 - Ext/48": 0,
      "3 - Ext/49": 0,
      "Bill 4/1": 5720000,
      "3M/1": 174260,
      "3M/2": 63500,
      "3M/3": 1731500,
      "3M/4": 148500,
      "3M/5": 125200,
      "3M/6": 70500,
      "3M/7": 302500,
      "3M/8": 100000,
      "3M/9": 0,
      "4.1-M/1": 1739125,
      "4.1-M/2": 0,
      "4.2-M/1": 2053750,
      "4.2-M/2": 0,
      "4.3-M/1": 1835125,
      "4.3-M/2": 0,
      "4.4-M/1": 1896250,
      "4.4-M/2": 0
    }
  },
  "pages": [
    {
      "page_ref": "GR1/1",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 313190338.5787259,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/1-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Where any item, clause or sub-clause of the General Requirements has not been priced, it will be deemed that the value of such item, clause or sub-clause is included in the rates for measured items elsewhere in the Bills of Quantities.",
          "full_description": "Generally — Where any item, clause or sub-clause of the General Requirements has not been priced, it will be deemed that the value of such item, clause or sub-clause is included in the rates for measured items elsewhere in the Bills of Quantities.",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 8
          }
        },
        {
          "id": "GR1/1-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "Generally"
          ],
          "own_description": "The rates and prices in these Bills of Quantities are fixed for the duration of the Contract and shall not be subject to any adjustment in respect of rise or fall in the cost of labour, materials, plant, equipment, transport or any other matters affecting the cost of execution of the Contract.",
          "full_description": "Generally — The rates and prices in these Bills of Quantities are fixed for the duration of the Contract and shall not be subject to any adjustment in respect of rise or fall in the cost of labour, materials, plant, equipment, transport or any other matters affecting the cost of execution of the Contract.",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "GR1",
            "row": 10
          }
        },
        {
          "id": "GR1/1-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "Generally"
          ],
          "own_description": "References hereunder to the Schedule of Project Requirements (SOPR) are intended solely to direct the Contractor to the specific requirements of the Schedule of Project Requirements in respect of a particular item and do not in any way limit the scope of such item to the requirements of the Schedule of Project Requirements.",
          "full_description": "Generally — References hereunder to the Schedule of Project Requirements (SOPR) are intended solely to direct the Contractor to the specific requirements of the Schedule of Project Requirements in respect of a particular item and do not in any way limit the scope of such item to the requirements of the Schedule of Project Requirements.",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 12
          }
        }
      ]
    },
    {
      "page_ref": "GR1/2",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/2-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "1  As per Emaar standard CoC",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 1  As per Emaar standard CoC",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 46
          }
        },
        {
          "id": "GR1/2-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "2  Advance Payment Guarantee",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 2  Advance Payment Guarantee",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 48
          }
        },
        {
          "id": "GR1/2-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "3  Performance Bond",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 3  Performance Bond",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 50
          }
        },
        {
          "id": "GR1/2-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "4  Contractor's All Risk Policy",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 4  Contractor's All Risk Policy",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "By Employer",
          "amount_state": "text",
          "source": {
            "sheet": "GR1",
            "row": 52
          }
        },
        {
          "id": "GR1/2-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "5  Workmen's Compensation Insurance",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 5  Workmen's Compensation Insurance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 54
          }
        },
        {
          "id": "GR1/2-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "6  Professional Indemnity insurance",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 6  Professional Indemnity insurance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 56
          }
        },
        {
          "id": "GR1/2-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "7  Third Party liability insurance",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 7  Third Party liability insurance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "By Employer",
          "amount_state": "text",
          "source": {
            "sheet": "GR1",
            "row": 58
          }
        },
        {
          "id": "GR1/2-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "8  Plant and Contractor's Equipment Insurance",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 8  Plant and Contractor's Equipment Insurance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 60
          }
        },
        {
          "id": "GR1/2-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "9  Motor Vehicle Third Party and Passenger Liability Insurance",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — 9  Motor Vehicle Third Party and Passenger Liability Insurance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 62
          }
        }
      ]
    },
    {
      "page_ref": "GR1/3",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [
        "A2 - Specifications"
      ],
      "items": [
        {
          "id": "GR1/3-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A1.1- Schedule of Clauses"
          ],
          "own_description": "The Contractor shall price hereunder any special requirements related to the  specification clauses",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A1.1- Schedule of Clauses — The Contractor shall price hereunder any special requirements related to the  specification clauses",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 89
          }
        }
      ]
    },
    {
      "page_ref": "GR1/4",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/4-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A3 - Restrictions"
          ],
          "own_description": "1 Access for and Possession or use of the Site",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A3 - Restrictions — 1 Access for and Possession or use of the Site",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 139
          }
        },
        {
          "id": "GR1/4-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A3 - Restrictions"
          ],
          "own_description": "2 Limitations of working space",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A3 - Restrictions — 2 Limitations of working space",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 141
          }
        },
        {
          "id": "GR1/4-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A3 - Restrictions"
          ],
          "own_description": "3 Limitations of working hours",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A3 - Restrictions — 3 Limitations of working hours",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 143
          }
        },
        {
          "id": "GR1/4-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A3 - Restrictions"
          ],
          "own_description": "4 The Maintenance of existing services on, under or over the Site",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A3 - Restrictions — 4 The Maintenance of existing services on, under or over the Site",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 145
          }
        },
        {
          "id": "GR1/4-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A1 - Conditions of Contract",
            "The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately",
            "A3 - Restrictions"
          ],
          "own_description": "5 The Execution of the Works in the required specific order, sections or phases",
          "full_description": "A1 - Conditions of Contract — The Contractor shall price hereunder any obligations contained in the Conditions of Contract which are not allowed for elsewhere and which the Contractor wishes to price separately — A3 - Restrictions — 5 The Execution of the Works in the required specific order, sections or phases",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 147
          }
        }
      ]
    },
    {
      "page_ref": "GR1/5",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/5-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "i.    Establishment",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — i.    Establishment",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 193
          }
        },
        {
          "id": "GR1/5-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "ii.    Maintenance",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — ii.    Maintenance",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 195
          }
        },
        {
          "id": "GR1/5-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "iii.    Removal",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — iii.    Removal",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 197
          }
        },
        {
          "id": "GR1/5-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "2  Supervision",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — 2  Supervision",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 199
          }
        },
        {
          "id": "GR1/5-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "3  Security",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — 3  Security",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 201
          }
        },
        {
          "id": "GR1/5-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "4  Safety, health and welfare of workpeople",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — 4  Safety, health and welfare of workpeople",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 203
          }
        },
        {
          "id": "GR1/5-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "A4 - Contractor's Administrative Arrangement",
            "A4.1- An item shall be given for contractor's administrative arrangements, which shall include:",
            "1  Office for the Contract administrators"
          ],
          "own_description": "5  Transport of workpeople",
          "full_description": "A4 - Contractor's Administrative Arrangement — A4.1- An item shall be given for contractor's administrative arrangements, which shall include: — 1  Office for the Contract administrators — 5  Transport of workpeople",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 205
          }
        }
      ]
    },
    {
      "page_ref": "GR1/6",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/6-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "1  Small plant and tools"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 1  Small plant and tools — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 243
          }
        },
        {
          "id": "GR1/6-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "1  Small plant and tools"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 1  Small plant and tools — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 245
          }
        },
        {
          "id": "GR1/6-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "1  Small plant and tools"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 1  Small plant and tools — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 247
          }
        },
        {
          "id": "GR1/6-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "2  Scaffoldings"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 2  Scaffoldings — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 251
          }
        },
        {
          "id": "GR1/6-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "2  Scaffoldings"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 2  Scaffoldings — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 253
          }
        },
        {
          "id": "GR1/6-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "2  Scaffoldings"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 2  Scaffoldings — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 255
          }
        },
        {
          "id": "GR1/6-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "3  Cranes and lifting plant"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 3  Cranes and lifting plant — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 259
          }
        },
        {
          "id": "GR1/6-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "3  Cranes and lifting plant"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 3  Cranes and lifting plant — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 261
          }
        },
        {
          "id": "GR1/6-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "3  Cranes and lifting plant"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 3  Cranes and lifting plant — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 263
          }
        },
        {
          "id": "GR1/6-K",
          "item_code": "K",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "4  Plant required for specific trades"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 4  Plant required for specific trades — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 267
          }
        },
        {
          "id": "GR1/6-L",
          "item_code": "L",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "4  Plant required for specific trades"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 4  Plant required for specific trades — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 269
          }
        },
        {
          "id": "GR1/6-M",
          "item_code": "M",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "4  Plant required for specific trades"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 4  Plant required for specific trades — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 271
          }
        },
        {
          "id": "GR1/6-N",
          "item_code": "N",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "5  Site Transport"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 5  Site Transport — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 275
          }
        },
        {
          "id": "GR1/6-P",
          "item_code": "P",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "5  Site Transport"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 5  Site Transport — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 277
          }
        },
        {
          "id": "GR1/6-Q",
          "item_code": "Q",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "5  Site Transport"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 5  Site Transport — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 279
          }
        },
        {
          "id": "GR1/6-R",
          "item_code": "R",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "5  Site Transport"
          ],
          "own_description": "6  Other plant not listed above but necessary for the completion of the Works",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — 5  Site Transport — 6  Other plant not listed above but necessary for the completion of the Works",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 281
          }
        }
      ]
    },
    {
      "page_ref": "GR1/7",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/7-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "A6 - Employer's Facilities",
            "Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include:",
            "1 - Temporary fully functional site facilities"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — A6 - Employer's Facilities — Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include: — 1 - Temporary fully functional site facilities — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 294
          }
        },
        {
          "id": "GR1/7-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "A6 - Employer's Facilities",
            "Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include:",
            "1 - Temporary fully functional site facilities"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — A6 - Employer's Facilities — Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include: — 1 - Temporary fully functional site facilities — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 296
          }
        },
        {
          "id": "GR1/7-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A5 - Constructional Plant",
            "A5.1 An item shall be given for constructional plant, which shall include:",
            "A6 - Employer's Facilities",
            "Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include:",
            "1 - Temporary fully functional site facilities"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A5 - Constructional Plant — A5.1 An item shall be given for constructional plant, which shall include: — A6 - Employer's Facilities — Particulars shall be given of any facilities required for the Employer or the Employer's representatives, which shall include: — 1 - Temporary fully functional site facilities — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 298
          }
        },
        {
          "id": "GR1/7-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "2 - Telephones, including costs of calls"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "2 - Telephones, including costs of calls — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 302
          }
        },
        {
          "id": "GR1/7-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "2 - Telephones, including costs of calls"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "2 - Telephones, including costs of calls — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 304
          }
        },
        {
          "id": "GR1/7-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "2 - Telephones, including costs of calls"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "2 - Telephones, including costs of calls — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 306
          }
        },
        {
          "id": "GR1/7-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "2 - Telephones, including costs of calls"
          ],
          "own_description": "3 - Attendance of staff (for example, drivers, laboratory assistants)",
          "full_description": "2 - Telephones, including costs of calls — 3 - Attendance of staff (for example, drivers, laboratory assistants)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 308
          }
        },
        {
          "id": "GR1/7-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "4 - Equipment (for example surveying equipment, laboratory equipment)"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "4 - Equipment (for example surveying equipment, laboratory equipment) — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 312
          }
        },
        {
          "id": "GR1/7-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "4 - Equipment (for example surveying equipment, laboratory equipment)"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "4 - Equipment (for example surveying equipment, laboratory equipment) — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 314
          }
        },
        {
          "id": "GR1/7-K",
          "item_code": "K",
          "section": "",
          "heading_path": [
            "4 - Equipment (for example surveying equipment, laboratory equipment)"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "4 - Equipment (for example surveying equipment, laboratory equipment) — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 316
          }
        },
        {
          "id": "GR1/7-L",
          "item_code": "L",
          "section": "",
          "heading_path": [
            "4 - Equipment (for example surveying equipment, laboratory equipment)"
          ],
          "own_description": "5 - Special requirements for programmes or progress charts",
          "full_description": "4 - Equipment (for example surveying equipment, laboratory equipment) — 5 - Special requirements for programmes or progress charts",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 318
          }
        }
      ]
    },
    {
      "page_ref": "GR1/8",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/8-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "6  Any other facilities (for example, progress photographs)."
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "6  Any other facilities (for example, progress photographs). — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 339
          }
        },
        {
          "id": "GR1/8-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "6  Any other facilities (for example, progress photographs)."
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "6  Any other facilities (for example, progress photographs). — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 341
          }
        },
        {
          "id": "GR1/8-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "6  Any other facilities (for example, progress photographs)."
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "6  Any other facilities (for example, progress photographs). — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 343
          }
        },
        {
          "id": "GR1/8-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "Signboard"
          ],
          "own_description": "Existing signboard to be taken over from Enabling Works contractor and Main Works contractor to update the names, maintain as required, remove after completion of the Works",
          "full_description": "Signboard — Existing signboard to be taken over from Enabling Works contractor and Main Works contractor to update the names, maintain as required, remove after completion of the Works",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 348
          }
        }
      ]
    },
    {
      "page_ref": "GR1/9",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/9-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A7 - Contractor's Facilities",
            "A7.1 An item shall be given for facilities required by the contractor, which shall include:",
            "1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "A7 - Contractor's Facilities — A7.1 An item shall be given for facilities required by the contractor, which shall include: — 1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 389
          }
        },
        {
          "id": "GR1/9-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A7 - Contractor's Facilities",
            "A7.1 An item shall be given for facilities required by the contractor, which shall include:",
            "1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "A7 - Contractor's Facilities — A7.1 An item shall be given for facilities required by the contractor, which shall include: — 1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 391
          }
        },
        {
          "id": "GR1/9-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A7 - Contractor's Facilities",
            "A7.1 An item shall be given for facilities required by the contractor, which shall include:",
            "1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "A7 - Contractor's Facilities — A7.1 An item shall be given for facilities required by the contractor, which shall include: — 1 - Contractor's Facilities, including offices, toilets, laboratories, compounds, stores, mess rooms — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 393
          }
        },
        {
          "id": "GR1/9-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "2 - Temporary fencing, hoardings"
          ],
          "own_description": "i.    Existing temporary site perimeter hoarding to be taken over from Enabling Works contractor and Main Works contractor to move / remove / adjust, maintain as required",
          "full_description": "2 - Temporary fencing, hoardings — i.    Existing temporary site perimeter hoarding to be taken over from Enabling Works contractor and Main Works contractor to move / remove / adjust, maintain as required",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 397
          }
        },
        {
          "id": "GR1/9-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "2 - Temporary fencing, hoardings"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "2 - Temporary fencing, hoardings — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 399
          }
        },
        {
          "id": "GR1/9-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "2 - Temporary fencing, hoardings"
          ],
          "own_description": "ii. Final Removal (Fixed Charges)",
          "full_description": "2 - Temporary fencing, hoardings — ii. Final Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 401
          }
        },
        {
          "id": "GR1/9-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "3  Screens and guardrails"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "3  Screens and guardrails — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 405
          }
        },
        {
          "id": "GR1/9-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "3  Screens and guardrails"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "3  Screens and guardrails — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 407
          }
        },
        {
          "id": "GR1/9-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "3  Screens and guardrails"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "3  Screens and guardrails — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 409
          }
        },
        {
          "id": "GR1/9-K",
          "item_code": "K",
          "section": "",
          "heading_path": [
            "4  Temporary roads, hard standings and crossings"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "4  Temporary roads, hard standings and crossings — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 413
          }
        },
        {
          "id": "GR1/9-L",
          "item_code": "L",
          "section": "",
          "heading_path": [
            "4  Temporary roads, hard standings and crossings"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "4  Temporary roads, hard standings and crossings — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 415
          }
        },
        {
          "id": "GR1/9-M",
          "item_code": "M",
          "section": "",
          "heading_path": [
            "4  Temporary roads, hard standings and crossings"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "4  Temporary roads, hard standings and crossings — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 417
          }
        }
      ]
    },
    {
      "page_ref": "GR1/10",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/10-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "5  Water for the Works"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "5  Water for the Works — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 433
          }
        },
        {
          "id": "GR1/10-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "5  Water for the Works"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "5  Water for the Works — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 435
          }
        },
        {
          "id": "GR1/10-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "5  Water for the Works"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "5  Water for the Works — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 437
          }
        },
        {
          "id": "GR1/10-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "6  Lighting and power for the Works"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "6  Lighting and power for the Works — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 441
          }
        },
        {
          "id": "GR1/10-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "6  Lighting and power for the Works"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "6  Lighting and power for the Works — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 443
          }
        },
        {
          "id": "GR1/10-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "6  Lighting and power for the Works"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "6  Lighting and power for the Works — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 445
          }
        },
        {
          "id": "GR1/10-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "7  Temporary telephones, electronic mail and facsimile"
          ],
          "own_description": "i.    Establishment (Fixed Charges)",
          "full_description": "7  Temporary telephones, electronic mail and facsimile — i.    Establishment (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 449
          }
        },
        {
          "id": "GR1/10-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "7  Temporary telephones, electronic mail and facsimile"
          ],
          "own_description": "ii.    Maintenance (Time Related Charges)",
          "full_description": "7  Temporary telephones, electronic mail and facsimile — ii.    Maintenance (Time Related Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 451
          }
        },
        {
          "id": "GR1/10-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "7  Temporary telephones, electronic mail and facsimile"
          ],
          "own_description": "iii.    Removal (Fixed Charges)",
          "full_description": "7  Temporary telephones, electronic mail and facsimile — iii.    Removal (Fixed Charges)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 453
          }
        }
      ]
    },
    {
      "page_ref": "GR1/11",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/11-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A8 - Temporary Works",
            "A8.1 An item shall be given for temporary works including design, which shall include:"
          ],
          "own_description": "1  Traffic diversion",
          "full_description": "A8 - Temporary Works — A8.1 An item shall be given for temporary works including design, which shall include: — 1  Traffic diversion",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 484
          }
        },
        {
          "id": "GR1/11-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A8 - Temporary Works",
            "A8.1 An item shall be given for temporary works including design, which shall include:"
          ],
          "own_description": "2  Access roads",
          "full_description": "A8 - Temporary Works — A8.1 An item shall be given for temporary works including design, which shall include: — 2  Access roads",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 486
          }
        },
        {
          "id": "GR1/11-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A8 - Temporary Works",
            "A8.1 An item shall be given for temporary works including design, which shall include:"
          ],
          "own_description": "3  Pumping",
          "full_description": "A8 - Temporary Works — A8.1 An item shall be given for temporary works including design, which shall include: — 3  Pumping",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 488
          }
        }
      ]
    },
    {
      "page_ref": "GR1/12",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/12-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "1 - Testing of materials",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 1 - Testing of materials",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 535
          }
        },
        {
          "id": "GR1/12-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "2 - Testing of the Works",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 2 - Testing of the Works",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 537
          }
        },
        {
          "id": "GR1/12-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "3 - Protecting the Works from inclement weather",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 3 - Protecting the Works from inclement weather",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 539
          }
        },
        {
          "id": "GR1/12-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "4 - Removing rubbish, protective casings and coverings and cleaning the Works at completion",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 4 - Removing rubbish, protective casings and coverings and cleaning the Works at completion",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 541
          }
        },
        {
          "id": "GR1/12-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "5 - Traffic regulations",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 5 - Traffic regulations",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 543
          }
        },
        {
          "id": "GR1/12-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "6 - Maintenance of public and private roads",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 6 - Maintenance of public and private roads",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 545
          }
        },
        {
          "id": "GR1/12-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "7 - Drying the Works",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 7 - Drying the Works",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 547
          }
        },
        {
          "id": "GR1/12-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "8 - Control of noise and pollution",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 8 - Control of noise and pollution",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 549
          }
        },
        {
          "id": "GR1/12-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "A9 - Sundry Items",
            "A9.1 An item shall be given for temporary works, which shall include:"
          ],
          "own_description": "9 -  All Statutory obligations",
          "full_description": "A9 - Sundry Items — A9.1 An item shall be given for temporary works, which shall include: — 9 -  All Statutory obligations",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 551
          }
        },
        {
          "id": "GR1/12-K",
          "item_code": "K",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "1 - Coordination with the Works by Others",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 1 - Coordination with the Works by Others",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 555
          }
        },
        {
          "id": "GR1/12-L",
          "item_code": "L",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "2 - Surveys, Setting-out and Levels",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 2 - Surveys, Setting-out and Levels",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 557
          }
        },
        {
          "id": "GR1/12-M",
          "item_code": "M",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "3 - Dust Control, Pest Control and Lightning Protection",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 3 - Dust Control, Pest Control and Lightning Protection",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 559
          }
        },
        {
          "id": "GR1/12-N",
          "item_code": "N",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "4 - Off site storage",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 4 - Off site storage",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 561
          }
        },
        {
          "id": "GR1/12-P",
          "item_code": "P",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "5 - Packing, marking, storage, handling and unpacking",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 5 - Packing, marking, storage, handling and unpacking",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 563
          }
        }
      ]
    },
    {
      "page_ref": "GR1/13",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/13-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "6 - Specialist Third Party Testing, Commissioning and Certification",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 6 - Specialist Third Party Testing, Commissioning and Certification",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 577
          }
        },
        {
          "id": "GR1/13-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "7 - Shop Drawings",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 7 - Shop Drawings",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 579
          }
        },
        {
          "id": "GR1/13-C",
          "item_code": "C",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "8 - Submittal program, drawings and revisions",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 8 - Submittal program, drawings and revisions",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 581
          }
        },
        {
          "id": "GR1/13-D",
          "item_code": "D",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "9 - Method Statements",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 9 - Method Statements",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 583
          }
        },
        {
          "id": "GR1/13-E",
          "item_code": "E",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "10 - Operation and Maintenance Manuals",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 10 - Operation and Maintenance Manuals",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 585
          }
        },
        {
          "id": "GR1/13-F",
          "item_code": "F",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "11 - Building Information Modelling (BIM) System",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 11 - Building Information Modelling (BIM) System",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 587
          }
        },
        {
          "id": "GR1/13-G",
          "item_code": "G",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "12 - Project Management System - Unifier",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 12 - Project Management System - Unifier",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 589
          }
        },
        {
          "id": "GR1/13-H",
          "item_code": "H",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "12 - Internet connection requirements on site",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 12 - Internet connection requirements on site",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 591
          }
        },
        {
          "id": "GR1/13-J",
          "item_code": "J",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "13 - Precautions against Fire",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 13 - Precautions against Fire",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 593
          }
        },
        {
          "id": "GR1/13-K",
          "item_code": "K",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "15 - Project Health, Safety, Environment and Security Guidelines",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 15 - Project Health, Safety, Environment and Security Guidelines",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 595
          }
        },
        {
          "id": "GR1/13-L",
          "item_code": "L",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "16 - General cleaning and waste disposal during construction",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 16 - General cleaning and waste disposal during construction",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 597
          }
        },
        {
          "id": "GR1/13-M",
          "item_code": "M",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "17 - Final Cleaning for Project Handover",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 17 - Final Cleaning for Project Handover",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 599
          }
        },
        {
          "id": "GR1/13-N",
          "item_code": "N",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "18 - Provision of Handover Documentation",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 18 - Provision of Handover Documentation",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 601
          }
        },
        {
          "id": "GR1/13-P",
          "item_code": "P",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "19 - Contract Spares/Attic stock",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 19 - Contract Spares/Attic stock",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 603
          }
        },
        {
          "id": "GR1/13-Q",
          "item_code": "Q",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "20 - As-built drawings",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 20 - As-built drawings",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 605
          }
        },
        {
          "id": "GR1/13-R",
          "item_code": "R",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "21 - Design of the Works to the extent provided for in the Contract",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 21 - Design of the Works to the extent provided for in the Contract",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 607
          }
        },
        {
          "id": "GR1/13-S",
          "item_code": "S",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "22 - Warranties",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 22 - Warranties",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 609
          }
        },
        {
          "id": "GR1/13-T",
          "item_code": "T",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "Waterproofing Warranties\r\n*Extra over for Consequential damages to other\r\nworks due to waterproofing damages: - Warranty\r\nfor waterproofing shall be inclusive of other related works which are necessary due to the defective water proofing, such as but not limited to removal and making good of tiles, painting, plastering, joinery works etc. This shall be mentioned in the Warranty Certificate.\r\n(Waterproofing warranty shall be covered within item S above)",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — Waterproofing Warranties\r\n*Extra over for Consequential damages to other\r\nworks due to waterproofing damages: - Warranty\r\nfor waterproofing shall be inclusive of other related works which are necessary due to the defective water proofing, such as but not limited to removal and making good of tiles, painting, plastering, joinery works etc. This shall be mentioned in the Warranty Certificate.\r\n(Waterproofing warranty shall be covered within item S above)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 611
          }
        }
      ]
    },
    {
      "page_ref": "GR1/14",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/14-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "23 - All mock-ups, prototypes and samples required by the Specification, the Drawings and the Schedule of Project Requirements",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 23 - All mock-ups, prototypes and samples required by the Specification, the Drawings and the Schedule of Project Requirements",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 624
          }
        },
        {
          "id": "GR1/14-B",
          "item_code": "B",
          "section": "",
          "heading_path": [
            "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor."
          ],
          "own_description": "24 - Provide for Employer's Requirements as per Appendix R of the SOPR",
          "full_description": "A9.2 Particulars shall be given where the nature or extent of the sundry items is not at the discretion of the Contractor. — 24 - Provide for Employer's Requirements as per Appendix R of the SOPR",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "GR1",
            "row": 626
          }
        }
      ]
    },
    {
      "page_ref": "GR1/15",
      "section": "",
      "sheet": "GR1",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "GR1/15-A",
          "item_code": "A",
          "section": "",
          "heading_path": [
            "Additional Items"
          ],
          "own_description": "Any items that may not be covered elsewhere in the Bills of Quantities which the Tenderer deemed to be necessary in order to carry out the works in full compliance with the SOPR  must be itemised and price below",
          "full_description": "Additional Items — Any items that may not be covered elsewhere in the Bills of Quantities which the Tenderer deemed to be necessary in order to carry out the works in full compliance with the SOPR  must be itemised and price below",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "GR1",
            "row": 673
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/1",
      "section": "SITE PREPARATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1528566,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/1-A",
          "item_code": "A",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Site clearance"
          ],
          "own_description": "Removal of debris, rubbish, vegetation, any existing foundation and services and the like prior to the commencement of main works; including disposal to approved location",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Site clearance — Removal of debris, rubbish, vegetation, any existing foundation and services and the like prior to the commencement of main works; including disposal to approved location",
          "quantity": 30688,
          "unit": "m2",
          "rate_aed": 6,
          "amount_aed": 184128,
          "amount_state": "number",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 11
          },
          "extra_columns": {
            "GF & Podium [D]": "30,688",
            "TOTAL QTY [I]": "30,688",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "184,128.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/1-B",
          "item_code": "B",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Anti-termite soil treatment; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Horizontal surface",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Anti-termite soil treatment; including surface preparation, accessories and all ancillary works as necessary — Horizontal surface",
          "quantity": 29102,
          "unit": "m2",
          "rate_aed": 6,
          "amount_aed": 174612,
          "amount_state": "number",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 15
          },
          "extra_columns": {
            "Basement [C]": "29,050",
            "GF & Podium [D]": "52",
            "TOTAL QTY [I]": "29,102",
            "BASEMENTS [M]": "174,300.00",
            "GF & PODIUM [N]": "312.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/1-C",
          "item_code": "C",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Anti-termite soil treatment; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical surface",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Anti-termite soil treatment; including surface preparation, accessories and all ancillary works as necessary — Vertical surface",
          "quantity": 19971,
          "unit": "m2",
          "rate_aed": 6,
          "amount_aed": 119826,
          "amount_state": "number",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 17
          },
          "extra_columns": {
            "Basement [C]": "19,971",
            "TOTAL QTY [I]": "19,971",
            "BASEMENTS [M]": "119,826.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/1-D",
          "item_code": "D",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete"
          ],
          "own_description": "Maintenance of de-watering system",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete — Maintenance of de-watering system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 1000000,
          "amount_aed": 1000000,
          "amount_state": "number",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 21
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,000,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/1-E",
          "item_code": "E",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete"
          ],
          "own_description": "Allow for removal of the dewatering system and closing of raft suction pipe opening, etc..",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete — Allow for removal of the dewatering system and closing of raft suction pipe opening, etc..",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 50000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 23
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "50,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/1-F",
          "item_code": "F",
          "section": "SITE PREPARATION",
          "heading_path": [
            "Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete"
          ],
          "own_description": "Confirm daily rate for maintenance of the dewatering system including all necessary fuel, spares, maintenance and attendance (RATE ONLY)",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — SITE PREPARATION — Dewatering; including design, maintenance,  consumables, accessories and all ancillary  works as necessary; complete — Confirm daily rate for maintenance of the dewatering system including all necessary fuel, spares, maintenance and attendance (RATE ONLY)",
          "quantity": null,
          "unit": "DAY",
          "rate_aed": 3900,
          "amount_aed": 0,
          "amount_printed": "Rate Only",
          "amount_state": "text",
          "printed_page": "2/B/1",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 25
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/2",
      "section": "BORED PILING",
      "sheet": "2 - Main",
      "source_collection_aed": 1745280,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/2-A",
          "item_code": "A",
          "section": "EARTHWORKS",
          "heading_path": [
            "Excavation",
            "Excavation works; including all ancillary works as necessary; from commencing level up to the required levels"
          ],
          "own_description": "Excavation to receive foundation excavation",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — EARTHWORKS — Excavation — Excavation works; including all ancillary works as necessary; from commencing level up to the required levels — Excavation to receive foundation excavation",
          "quantity": 3961,
          "unit": "m3",
          "rate_aed": 20,
          "amount_aed": 79220,
          "amount_state": "number",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 60
          },
          "extra_columns": {
            "Basement [C]": "3,961",
            "TOTAL QTY [I]": "3,961",
            "BASEMENTS [M]": "79,220.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/2-B",
          "item_code": "B",
          "section": "EARTHWORKS",
          "heading_path": [
            "Disposal",
            "Disposal of unsuitable and surplus materials arising from excavation; including all ancillary works as necessary"
          ],
          "own_description": "Removed on site including a suitable tip to approved location; including stockpiling",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — EARTHWORKS — Disposal — Disposal of unsuitable and surplus materials arising from excavation; including all ancillary works as necessary — Removed on site including a suitable tip to approved location; including stockpiling",
          "quantity": 3961,
          "unit": "m3",
          "rate_aed": 25,
          "amount_aed": 99025,
          "amount_state": "number",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 66
          },
          "extra_columns": {
            "Basement [C]": "3,961",
            "TOTAL QTY [I]": "3,961",
            "BASEMENTS [M]": "99,025.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/2-C",
          "item_code": "C",
          "section": "EARTHWORKS",
          "heading_path": [
            "Disposal",
            "Disposal of unsuitable and surplus materials arising from excavation; including all ancillary works as necessary"
          ],
          "own_description": "Removed off-site to approved location (RATE ONLY)",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — EARTHWORKS — Disposal — Disposal of unsuitable and surplus materials arising from excavation; including all ancillary works as necessary — Removed off-site to approved location (RATE ONLY)",
          "quantity": null,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Rate Only",
          "amount_state": "text",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 68
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/2-D",
          "item_code": "D",
          "section": "EARTHWORKS",
          "heading_path": [
            "Filling",
            "Filling; engineered filling materials including 95% MDD compaction, shoring, chemical treatment, and all ancillary works necessary"
          ],
          "own_description": "Compacted fill; various thickness; to slab on grade",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — EARTHWORKS — Filling — Filling; engineered filling materials including 95% MDD compaction, shoring, chemical treatment, and all ancillary works necessary — Compacted fill; various thickness; to slab on grade",
          "quantity": null,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 74
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/2-E",
          "item_code": "E",
          "section": "BORED PILING",
          "heading_path": [
            "Pile head treatment; including surface preparation, high strength cementitious grout, 15mm thick epoxy waterproofing grout; accessories and all ancillary works as necessary"
          ],
          "own_description": "1000mm diameter",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — BORED PILING — Pile head treatment; including surface preparation, high strength cementitious grout, 15mm thick epoxy waterproofing grout; accessories and all ancillary works as necessary — 1000mm diameter",
          "quantity": 758,
          "unit": "Nr.",
          "rate_aed": 1455,
          "amount_aed": 1102890,
          "amount_state": "number",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 81
          },
          "extra_columns": {
            "Basement [C]": "758",
            "TOTAL QTY [I]": "758",
            "BASEMENTS [M]": "1,102,890.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/2-F",
          "item_code": "F",
          "section": "BORED PILING",
          "heading_path": [
            "Pile head treatment; including surface preparation, high strength cementitious grout, 15mm thick epoxy waterproofing grout; accessories and all ancillary works as necessary"
          ],
          "own_description": "1500mm diameter",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — BORED PILING — Pile head treatment; including surface preparation, high strength cementitious grout, 15mm thick epoxy waterproofing grout; accessories and all ancillary works as necessary — 1500mm diameter",
          "quantity": 319,
          "unit": "Nr.",
          "rate_aed": 1455,
          "amount_aed": 464145,
          "amount_state": "number",
          "printed_page": "2/B/2",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 83
          },
          "extra_columns": {
            "Basement [C]": "319",
            "TOTAL QTY [I]": "319",
            "BASEMENTS [M]": "464,145.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/3",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/3-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Site Work in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION B - SITE WORKS (2/B) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Site Work in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/B/3",
          "bill_ref": "2",
          "section_ref": "2/B",
          "source": {
            "sheet": "2 - Main",
            "row": 102
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/4",
      "section": "POURED CONCRETE",
      "sheet": "2 - Main",
      "source_collection_aed": 18015000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/4-A",
          "item_code": "A",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Mass concrete; concrete grade C20/25"
          ],
          "own_description": "Blinding; 50mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Mass concrete; concrete grade C20/25 — Blinding; 50mm thick",
          "quantity": 1452,
          "unit": "m3",
          "rate_aed": 500,
          "amount_aed": 726000,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 216
          },
          "extra_columns": {
            "Basement [C]": "1,452",
            "TOTAL QTY [I]": "1,452",
            "BASEMENTS [M]": "726,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-B",
          "item_code": "B",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 150mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 150mm thick",
          "quantity": 4,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 220
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "600.00",
            "TOWER 3 [Q]": "600.00",
            "TOWER 4 [R]": "600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-C",
          "item_code": "C",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 200mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 200mm thick",
          "quantity": 3843,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2305800,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 222
          },
          "extra_columns": {
            "Basement [C]": "113",
            "GF & Podium [D]": "257",
            "Tower 1 [E]": "816",
            "Tower 2 [F]": "917",
            "Tower 3 [G]": "893",
            "Tower 4 [H]": "847",
            "TOTAL QTY [I]": "3,843",
            "BASEMENTS [M]": "67,800.00",
            "GF & PODIUM [N]": "154,200.00",
            "TOWER 1 [O]": "489,600.00",
            "TOWER 2 [P]": "550,200.00",
            "TOWER 3 [Q]": "535,800.00",
            "TOWER 4 [R]": "508,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-D",
          "item_code": "D",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 220mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 220mm thick",
          "quantity": 7258,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 4354800,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 224
          },
          "extra_columns": {
            "Basement [C]": "5,419",
            "GF & Podium [D]": "1,834",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "7,258",
            "BASEMENTS [M]": "3,251,400.00",
            "GF & PODIUM [N]": "1,100,400.00",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-E",
          "item_code": "E",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 240mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 240mm thick",
          "quantity": 87,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 52200,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "46,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-F",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 250mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 250mm thick",
          "quantity": 606,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 363600,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "97",
            "Tower 2 [F]": "191",
            "Tower 3 [G]": "85",
            "Tower 4 [H]": "135",
            "TOTAL QTY [I]": "606",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,800.00",
            "TOWER 1 [O]": "58,200.00",
            "TOWER 2 [P]": "114,600.00",
            "TOWER 3 [Q]": "51,000.00",
            "TOWER 4 [R]": "81,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-G",
          "item_code": "G",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 260mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 260mm thick",
          "quantity": 85,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 51000,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 230
          },
          "extra_columns": {
            "Basement [C]": "74",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "44,400.00",
            "GF & PODIUM [N]": "6,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-H",
          "item_code": "H",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 275mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 275mm thick",
          "quantity": 3,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "600.00",
            "TOWER 3 [Q]": "600.00",
            "TOWER 4 [R]": "600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-J",
          "item_code": "J",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 280mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 280mm thick",
          "quantity": 63,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 37800,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-K",
          "item_code": "K",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 300mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 300mm thick",
          "quantity": 2952,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1771200,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 236
          },
          "extra_columns": {
            "Basement [C]": "214",
            "GF & Podium [D]": "1,835",
            "Tower 1 [E]": "198",
            "Tower 2 [F]": "359",
            "Tower 3 [G]": "189",
            "Tower 4 [H]": "157",
            "TOTAL QTY [I]": "2,952",
            "BASEMENTS [M]": "128,400.00",
            "GF & PODIUM [N]": "1,101,000.00",
            "TOWER 1 [O]": "118,800.00",
            "TOWER 2 [P]": "215,400.00",
            "TOWER 3 [Q]": "113,400.00",
            "TOWER 4 [R]": "94,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-L",
          "item_code": "L",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 350mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 350mm thick",
          "quantity": 8006,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 4803600,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6,449",
            "Tower 1 [E]": "346",
            "Tower 2 [F]": "460",
            "Tower 3 [G]": "409",
            "Tower 4 [H]": "342",
            "TOTAL QTY [I]": "8,006",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,869,400.00",
            "TOWER 1 [O]": "207,600.00",
            "TOWER 2 [P]": "276,000.00",
            "TOWER 3 [Q]": "245,400.00",
            "TOWER 4 [R]": "205,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-M",
          "item_code": "M",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 400mm thick",
          "quantity": 219,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 131400,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "116",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "53",
            "TOTAL QTY [I]": "219",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "69,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "30,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-N",
          "item_code": "N",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 450mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 450mm thick",
          "quantity": 406,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 243600,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "406",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "406",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "243,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-P",
          "item_code": "P",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 500mm thick",
          "quantity": 2,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-Q",
          "item_code": "Q",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 600mm thick",
          "quantity": 854,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 512400,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "211",
            "Tower 2 [F]": "222",
            "Tower 3 [G]": "214",
            "Tower 4 [H]": "207",
            "TOTAL QTY [I]": "854",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "126,600.00",
            "TOWER 2 [P]": "133,200.00",
            "TOWER 3 [Q]": "128,400.00",
            "TOWER 4 [R]": "124,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-R",
          "item_code": "R",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Suspended slabs; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Suspended slabs; 700mm thick",
          "quantity": 1833,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1099800,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1,224",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "609",
            "TOTAL QTY [I]": "1,833",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "734,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "365,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-S",
          "item_code": "S",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Slab on grade; 250mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Slab on grade; 250mm thick",
          "quantity": 0,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-T",
          "item_code": "T",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Basement wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Basement wall; 400mm thick",
          "quantity": 2589,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1553400,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 252
          },
          "extra_columns": {
            "Basement [C]": "2,589",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,589",
            "BASEMENTS [M]": "1,553,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/4-U",
          "item_code": "U",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Basement wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Basement wall; 500mm thick",
          "quantity": 5,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/C/1",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 254
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/5",
      "section": "POURED CONCRETE",
      "sheet": "2 - Main",
      "source_collection_aed": 38937000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/5-A",
          "item_code": "A",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Raft foundations",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Raft foundations",
          "quantity": 41614,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 24968400,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 270
          },
          "extra_columns": {
            "Basement [C]": "41,614",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41,614",
            "BASEMENTS [M]": "24,968,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-B",
          "item_code": "B",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Ramps",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Ramps",
          "quantity": 445,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 267000,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 272
          },
          "extra_columns": {
            "Basement [C]": "280",
            "GF & Podium [D]": "165",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "445",
            "BASEMENTS [M]": "168,000.00",
            "GF & PODIUM [N]": "99,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-C",
          "item_code": "C",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Lintel beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Lintel beams",
          "quantity": 246,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 147600,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 274
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "50",
            "Tower 2 [F]": "55",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "246",
            "BASEMENTS [M]": "3,600.00",
            "GF & PODIUM [N]": "18,000.00",
            "TOWER 1 [O]": "30,000.00",
            "TOWER 2 [P]": "33,000.00",
            "TOWER 3 [Q]": "31,800.00",
            "TOWER 4 [R]": "31,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-D",
          "item_code": "D",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Upstand",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Upstand",
          "quantity": 333,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 199800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 276
          },
          "extra_columns": {
            "Basement [C]": "54",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "69",
            "Tower 2 [F]": "63",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "87",
            "TOTAL QTY [I]": "333",
            "BASEMENTS [M]": "32,400.00",
            "GF & PODIUM [N]": "5,400.00",
            "TOWER 1 [O]": "41,400.00",
            "TOWER 2 [P]": "37,800.00",
            "TOWER 3 [Q]": "30,600.00",
            "TOWER 4 [R]": "52,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-E",
          "item_code": "E",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Downstand",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Downstand",
          "quantity": 103,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 61800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,200.00",
            "TOWER 1 [O]": "22,800.00",
            "TOWER 2 [P]": "11,400.00",
            "TOWER 3 [Q]": "1,200.00",
            "TOWER 4 [R]": "10,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-F",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Parapet",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Parapet",
          "quantity": 46,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 27600,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 280
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-G",
          "item_code": "G",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Staircase",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Staircase",
          "quantity": 2086,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1251600,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 282
          },
          "extra_columns": {
            "Basement [C]": "159",
            "GF & Podium [D]": "275",
            "Tower 1 [E]": "395",
            "Tower 2 [F]": "438",
            "Tower 3 [G]": "420",
            "Tower 4 [H]": "399",
            "TOTAL QTY [I]": "2,086",
            "BASEMENTS [M]": "95,400.00",
            "GF & PODIUM [N]": "165,000.00",
            "TOWER 1 [O]": "237,000.00",
            "TOWER 2 [P]": "262,800.00",
            "TOWER 3 [Q]": "252,000.00",
            "TOWER 4 [R]": "239,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-H",
          "item_code": "H",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "RC Plinth; various thickness",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — RC Plinth; various thickness",
          "quantity": 122,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 73200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 284
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "30",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "122",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "10,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,400.00",
            "TOWER 3 [Q]": "18,000.00",
            "TOWER 4 [R]": "15,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-J",
          "item_code": "J",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Columns",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Columns",
          "quantity": 2734,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 286
          },
          "extra_columns": {
            "Basement [C]": "1,539",
            "GF & Podium [D]": "1,195",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,734",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-K",
          "item_code": "K",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 250mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 250mm thick",
          "quantity": 7,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 4200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-L",
          "item_code": "L",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 300mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 300mm thick",
          "quantity": 538,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 322800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 290
          },
          "extra_columns": {
            "Basement [C]": "513",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "538",
            "BASEMENTS [M]": "307,800.00",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-M",
          "item_code": "M",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 400mm thick",
          "quantity": 498,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 298800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 292
          },
          "extra_columns": {
            "Basement [C]": "205",
            "GF & Podium [D]": "293",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "498",
            "BASEMENTS [M]": "123,000.00",
            "GF & PODIUM [N]": "175,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-N",
          "item_code": "N",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 500mm thick",
          "quantity": 1957,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1174200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 294
          },
          "extra_columns": {
            "Basement [C]": "1,305",
            "GF & Podium [D]": "652",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,957",
            "BASEMENTS [M]": "783,000.00",
            "GF & PODIUM [N]": "391,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-P",
          "item_code": "P",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 600mm thick",
          "quantity": 1008,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 604800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 296
          },
          "extra_columns": {
            "Basement [C]": "983",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,008",
            "BASEMENTS [M]": "589,800.00",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-Q",
          "item_code": "Q",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Core wall; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Core wall; 700mm thick",
          "quantity": 1602,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 961200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 298
          },
          "extra_columns": {
            "Basement [C]": "1,602",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,602",
            "BASEMENTS [M]": "961,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-R",
          "item_code": "R",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Beams",
          "quantity": 3983,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2389800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 300
          },
          "extra_columns": {
            "Basement [C]": "236",
            "GF & Podium [D]": "2,059",
            "Tower 1 [E]": "344",
            "Tower 2 [F]": "504",
            "Tower 3 [G]": "370",
            "Tower 4 [H]": "470",
            "TOTAL QTY [I]": "3,983",
            "BASEMENTS [M]": "141,600.00",
            "GF & PODIUM [N]": "1,235,400.00",
            "TOWER 1 [O]": "206,400.00",
            "TOWER 2 [P]": "302,400.00",
            "TOWER 3 [Q]": "222,000.00",
            "TOWER 4 [R]": "282,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-S",
          "item_code": "S",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Drop panels",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Drop panels",
          "quantity": 929,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 557400,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 302
          },
          "extra_columns": {
            "Basement [C]": "115",
            "GF & Podium [D]": "803",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "929",
            "BASEMENTS [M]": "69,000.00",
            "GF & PODIUM [N]": "481,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-T",
          "item_code": "T",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Pile caps",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Pile caps",
          "quantity": 6334,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 3800400,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 304
          },
          "extra_columns": {
            "Basement [C]": "6,334",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6,334",
            "BASEMENTS [M]": "3,800,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-U",
          "item_code": "U",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Second cast walls; 150mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Second cast walls; 150mm thick",
          "quantity": 483,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 289800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 306
          },
          "extra_columns": {
            "Basement [C]": "26",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "185",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "75",
            "Tower 4 [H]": "82",
            "TOTAL QTY [I]": "483",
            "BASEMENTS [M]": "15,600.00",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "111,000.00",
            "TOWER 2 [P]": "54,000.00",
            "TOWER 3 [Q]": "45,000.00",
            "TOWER 4 [R]": "49,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-V",
          "item_code": "V",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Second cast walls; 200mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Second cast walls; 200mm thick",
          "quantity": 418,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 250800,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 308
          },
          "extra_columns": {
            "Basement [C]": "37",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "123",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "119",
            "TOTAL QTY [I]": "418",
            "BASEMENTS [M]": "22,200.00",
            "GF & PODIUM [N]": "21,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "73,800.00",
            "TOWER 3 [Q]": "62,400.00",
            "TOWER 4 [R]": "71,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-W",
          "item_code": "W",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Blade wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Blade wall; 500mm thick",
          "quantity": 962,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 577200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 310
          },
          "extra_columns": {
            "Basement [C]": "962",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "962",
            "BASEMENTS [M]": "577,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-X",
          "item_code": "X",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Blade wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Blade wall; 600mm thick",
          "quantity": 339,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 203400,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 312
          },
          "extra_columns": {
            "Basement [C]": "339",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "339",
            "BASEMENTS [M]": "203,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-Y",
          "item_code": "Y",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Blade wall; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Blade wall; 700mm thick",
          "quantity": 609,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 365400,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 314
          },
          "extra_columns": {
            "Basement [C]": "609",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "609",
            "BASEMENTS [M]": "365,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-Z",
          "item_code": "Z",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Blade wall; 800mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Blade wall; 800mm thick",
          "quantity": 27,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 16200,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 316
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "16,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/5-AA",
          "item_code": "AA",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Blade wall; 900mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Blade wall; 900mm thick",
          "quantity": 206,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 123600,
          "amount_state": "number",
          "printed_page": "2/C/2",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 318
          },
          "extra_columns": {
            "Basement [C]": "206",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "123,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/6",
      "section": "POURED CONCRETE",
      "sheet": "2 - Main",
      "source_collection_aed": 48192600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/6-F",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Columns",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Columns",
          "quantity": 4850,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2910000,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 329
          },
          "extra_columns": {
            "Basement [C]": "1,539",
            "GF & Podium [D]": "1,245",
            "Tower 1 [E]": "414",
            "Tower 2 [F]": "574",
            "Tower 3 [G]": "566",
            "Tower 4 [H]": "512",
            "TOTAL QTY [I]": "4,850",
            "BASEMENTS [M]": "923,400.00",
            "GF & PODIUM [N]": "747,000.00",
            "TOWER 1 [O]": "248,400.00",
            "TOWER 2 [P]": "344,400.00",
            "TOWER 3 [Q]": "339,600.00",
            "TOWER 4 [R]": "307,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-A",
          "item_code": "A",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Coupling beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Coupling beams",
          "quantity": 827,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 496200,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 331
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "154",
            "Tower 2 [F]": "249",
            "Tower 3 [G]": "219",
            "Tower 4 [H]": "201",
            "TOTAL QTY [I]": "827",
            "BASEMENTS [M]": "600.00",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "92,400.00",
            "TOWER 2 [P]": "149,400.00",
            "TOWER 3 [Q]": "131,400.00",
            "TOWER 4 [R]": "120,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-B",
          "item_code": "B",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Blade wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Blade wall; 400mm thick",
          "quantity": 2204,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1322400,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "483",
            "Tower 1 [E]": "1,116",
            "Tower 2 [F]": "415",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "171",
            "TOTAL QTY [I]": "2,204",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "289,800.00",
            "TOWER 1 [O]": "669,600.00",
            "TOWER 2 [P]": "249,000.00",
            "TOWER 3 [Q]": "11,400.00",
            "TOWER 4 [R]": "102,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-C",
          "item_code": "C",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Blade wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Blade wall; 500mm thick",
          "quantity": 3605,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2163000,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "96",
            "Tower 1 [E]": "74",
            "Tower 2 [F]": "937",
            "Tower 3 [G]": "1,304",
            "Tower 4 [H]": "1,194",
            "TOTAL QTY [I]": "3,605",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "57,600.00",
            "TOWER 1 [O]": "44,400.00",
            "TOWER 2 [P]": "562,200.00",
            "TOWER 3 [Q]": "782,400.00",
            "TOWER 4 [R]": "716,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-D",
          "item_code": "D",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Blade wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Blade wall; 600mm thick",
          "quantity": 96,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 337
          },
          "extra_columns": {
            "Basement [C]": "96",
            "GF & Podium [D]": "0",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-E",
          "item_code": "E",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Core wall; 300mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Core wall; 300mm thick",
          "quantity": 4649,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2789400,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 339
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "Tower 1 [E]": "851",
            "Tower 2 [F]": "1,500",
            "Tower 3 [G]": "1,085",
            "Tower 4 [H]": "1,213",
            "TOTAL QTY [I]": "4,649",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "510,600.00",
            "TOWER 2 [P]": "900,000.00",
            "TOWER 3 [Q]": "651,000.00",
            "TOWER 4 [R]": "727,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-F#2",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Core wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Core wall; 400mm thick",
          "quantity": 7165,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 4299000,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 341
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "Tower 1 [E]": "2,463",
            "Tower 2 [F]": "2,110",
            "Tower 3 [G]": "1,180",
            "Tower 4 [H]": "1,412",
            "TOTAL QTY [I]": "7,165",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,477,800.00",
            "TOWER 2 [P]": "1,266,000.00",
            "TOWER 3 [Q]": "708,000.00",
            "TOWER 4 [R]": "847,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-G",
          "item_code": "G",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Core wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Core wall; 500mm thick",
          "quantity": 7341,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 4404600,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 343
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "Tower 1 [E]": "148",
            "Tower 2 [F]": "1,843",
            "Tower 3 [G]": "3,207",
            "Tower 4 [H]": "2,143",
            "TOTAL QTY [I]": "7,341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "88,800.00",
            "TOWER 2 [P]": "1,105,800.00",
            "TOWER 3 [Q]": "1,924,200.00",
            "TOWER 4 [R]": "1,285,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-H",
          "item_code": "H",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Core wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Core wall; 600mm thick",
          "quantity": 0,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 345
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "Tower 1 [E]": "0",
            "Tower 3 [G]": "0",
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-J",
          "item_code": "J",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C56/70"
          ],
          "own_description": "Pedestal; various thickness",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C56/70 — Pedestal; various thickness",
          "quantity": 72,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 43200,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "72",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,800.00",
            "TOWER 1 [O]": "7,800.00",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "7,800.00",
            "TOWER 4 [R]": "7,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-L",
          "item_code": "L",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Columns",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Columns",
          "quantity": 3963,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 2575950,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 351
          },
          "extra_columns": {
            "Basement [C]": "418",
            "GF & Podium [D]": "714",
            "Tower 1 [E]": "616",
            "Tower 2 [F]": "740",
            "Tower 3 [G]": "735",
            "Tower 4 [H]": "740",
            "TOTAL QTY [I]": "3,963",
            "BASEMENTS [M]": "271,700.00",
            "GF & PODIUM [N]": "464,100.00",
            "TOWER 1 [O]": "400,400.00",
            "TOWER 2 [P]": "481,000.00",
            "TOWER 3 [Q]": "477,750.00",
            "TOWER 4 [R]": "481,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-M",
          "item_code": "M",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 400mm thick",
          "quantity": 1721,
          "unit": "m3",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 353
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,116",
            "Tower 2 [F]": "415",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "171",
            "TOTAL QTY [I]": "1,721",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-N",
          "item_code": "N",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 500mm thick",
          "quantity": 2167,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 1408550,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 355
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "242",
            "Tower 1 [E]": "1,925",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,167",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "157,300.00",
            "TOWER 1 [O]": "1,251,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-P",
          "item_code": "P",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 600mm thick",
          "quantity": 7646,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 4969900,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 357
          },
          "extra_columns": {
            "GF & Podium [D]": "2,293",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1,667",
            "Tower 3 [G]": "1,651",
            "Tower 4 [H]": "2,035",
            "TOTAL QTY [I]": "7,646",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,490,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,083,550.00",
            "TOWER 3 [Q]": "1,073,150.00",
            "TOWER 4 [R]": "1,322,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-Q",
          "item_code": "Q",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 700mm thick",
          "quantity": 1536,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 998400,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 359
          },
          "extra_columns": {
            "GF & Podium [D]": "1,536",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,536",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "998,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-R",
          "item_code": "R",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 800mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 800mm thick",
          "quantity": 43,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 27950,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 361
          },
          "extra_columns": {
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-S",
          "item_code": "S",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Blade wall; 900mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Blade wall; 900mm thick",
          "quantity": 174,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 113100,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 363
          },
          "extra_columns": {
            "GF & Podium [D]": "174",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "113,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-T",
          "item_code": "T",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Core wall; 300mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Core wall; 300mm thick",
          "quantity": 3530,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 2294500,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 365
          },
          "extra_columns": {
            "GF & Podium [D]": "563",
            "Tower 1 [E]": "734",
            "Tower 2 [F]": "740",
            "Tower 3 [G]": "763",
            "Tower 4 [H]": "730",
            "TOTAL QTY [I]": "3,530",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "365,950.00",
            "TOWER 1 [O]": "477,100.00",
            "TOWER 2 [P]": "481,000.00",
            "TOWER 3 [Q]": "495,950.00",
            "TOWER 4 [R]": "474,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-U",
          "item_code": "U",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Core wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Core wall; 400mm thick",
          "quantity": 1268,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 824200,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 367
          },
          "extra_columns": {
            "GF & Podium [D]": "117",
            "Tower 1 [E]": "1,151",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,268",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "76,050.00",
            "TOWER 1 [O]": "748,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-V",
          "item_code": "V",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Core wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Core wall; 500mm thick",
          "quantity": 9723,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 6319950,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 369
          },
          "extra_columns": {
            "GF & Podium [D]": "2,745",
            "Tower 1 [E]": "2,603",
            "Tower 2 [F]": "1,457",
            "Tower 3 [G]": "1,461",
            "Tower 4 [H]": "1,457",
            "TOTAL QTY [I]": "9,723",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,784,250.00",
            "TOWER 1 [O]": "1,691,950.00",
            "TOWER 2 [P]": "947,050.00",
            "TOWER 3 [Q]": "949,650.00",
            "TOWER 4 [R]": "947,050.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-W",
          "item_code": "W",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Core wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Core wall; 600mm thick",
          "quantity": 13391,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 8704150,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 371
          },
          "extra_columns": {
            "GF & Podium [D]": "1,869",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3,926",
            "Tower 3 [G]": "4,026",
            "Tower 4 [H]": "3,570",
            "TOTAL QTY [I]": "13,391",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,214,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,551,900.00",
            "TOWER 3 [Q]": "2,616,900.00",
            "TOWER 4 [R]": "2,320,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-X",
          "item_code": "X",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Core wall; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Core wall; 700mm thick",
          "quantity": 1131,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 735150,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 373
          },
          "extra_columns": {
            "GF & Podium [D]": "1,131",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "735,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/6-Y",
          "item_code": "Y",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C70/85"
          ],
          "own_description": "Coupling beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Reinforced concrete; concrete grade C70/85 — Coupling beams",
          "quantity": 1220,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 793000,
          "amount_state": "number",
          "printed_page": "2/C/3",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 375
          },
          "extra_columns": {
            "Basement [C]": "56",
            "GF & Podium [D]": "320",
            "Tower 1 [E]": "193",
            "Tower 2 [F]": "214",
            "Tower 3 [G]": "219",
            "Tower 4 [H]": "218",
            "TOTAL QTY [I]": "1,220",
            "BASEMENTS [M]": "36,400.00",
            "GF & PODIUM [N]": "208,000.00",
            "TOWER 1 [O]": "125,450.00",
            "TOWER 2 [P]": "139,100.00",
            "TOWER 3 [Q]": "142,350.00",
            "TOWER 4 [R]": "141,700.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/7",
      "section": "POURED CONCRETE",
      "sheet": "2 - Main",
      "source_collection_aed": 455700,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/7-A",
          "item_code": "A",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Pool suspended slabs; 300mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Pool suspended slabs; 300mm thick",
          "quantity": null,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 387
          },
          "extra_columns": {
            "Tower 2 [F]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-B",
          "item_code": "B",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Pool suspended slabs; 350mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Pool suspended slabs; 350mm thick",
          "quantity": 22,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 389
          },
          "extra_columns": {
            "Tower 2 [F]": "22",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-C",
          "item_code": "C",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Pool walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Pool walls",
          "quantity": 16,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 9600,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 391
          },
          "extra_columns": {
            "Tower 2 [F]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-D",
          "item_code": "D",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water tank wall; 500mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Water tank wall; 500mm thick",
          "quantity": 31,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 18600,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 393
          },
          "extra_columns": {
            "Basement [C]": "31",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "18,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-E",
          "item_code": "E",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sump pit wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Sump pit wall; 400mm thick",
          "quantity": 44,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 26400,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 395
          },
          "extra_columns": {
            "Basement [C]": "44",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "26,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-F",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sump pit floors; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Sump pit floors; 400mm thick",
          "quantity": 21,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 12600,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-G",
          "item_code": "G",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sump pit floors; 200mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Sump pit floors; 200mm thick",
          "quantity": 3,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 399
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "1",
            "Tower 2 [F]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-H",
          "item_code": "H",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sump pit wall; 250mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Sump pit wall; 250mm thick",
          "quantity": 13,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 401
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "5,400.00",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-J",
          "item_code": "J",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Pool walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Pool walls",
          "quantity": 18,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 403
          },
          "extra_columns": {
            "Tower 2 [F]": "18",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-K",
          "item_code": "K",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water tank wall; 400mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Water tank wall; 400mm thick",
          "quantity": 457,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 297050,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 407
          },
          "extra_columns": {
            "Basement [C]": "422",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "457",
            "BASEMENTS [M]": "274,300.00",
            "GF & PODIUM [N]": "22,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-L",
          "item_code": "L",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water tank wall; 600mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Water tank wall; 600mm thick",
          "quantity": 12,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/7-M",
          "item_code": "M",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water tank wall; 700mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C70/85; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Water tank wall; 700mm thick",
          "quantity": 77,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 50050,
          "amount_state": "number",
          "printed_page": "2/C/4",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 411
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "50,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/8",
      "section": "REINFORCEMENT",
      "sheet": "2 - Main",
      "source_collection_aed": 201742608,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/8-A",
          "item_code": "A",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Suspended slabs; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Suspended slabs; various diameter",
          "quantity": 5802.36,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 27851328,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 442
          },
          "extra_columns": {
            "Basement [C]": "1,280.32",
            "GF & Podium [D]": "2,490.46",
            "Tower 1 [E]": "366.58",
            "Tower 2 [F]": "754.22",
            "Tower 3 [G]": "392.42",
            "Tower 4 [H]": "518.36",
            "TOTAL QTY [I]": "5,802.36",
            "BASEMENTS [M]": "6,145,536.00",
            "GF & PODIUM [N]": "11,954,208.00",
            "TOWER 1 [O]": "1,759,584.00",
            "TOWER 2 [P]": "3,620,256.00",
            "TOWER 3 [Q]": "1,883,616.00",
            "TOWER 4 [R]": "2,488,128.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-B",
          "item_code": "B",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Slab on grade; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Slab on grade; various diameter",
          "quantity": 0,
          "unit": "t",
          "rate_aed": 0,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 444
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "0.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-C",
          "item_code": "C",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Basement walls; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Basement walls; various diameter",
          "quantity": 415.03999999999996,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 1992191.9999999998,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 446
          },
          "extra_columns": {
            "Basement [C]": "415.04",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "415.04",
            "BASEMENTS [M]": "1,992,192.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-D",
          "item_code": "D",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Raft foundations; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Raft foundations; various diameter",
          "quantity": 10403.5,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 49936800,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 448
          },
          "extra_columns": {
            "Basement [C]": "10,403.50",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "10,403.50",
            "BASEMENTS [M]": "49,936,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-E",
          "item_code": "E",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Lintel beams; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Lintel beams; various diameter",
          "quantity": 24.5,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 117600,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 450
          },
          "extra_columns": {
            "Basement [C]": "0.60",
            "GF & Podium [D]": "3.00",
            "Tower 1 [E]": "5.00",
            "Tower 2 [F]": "5.50",
            "Tower 3 [G]": "5.20",
            "Tower 4 [H]": "5.20",
            "TOTAL QTY [I]": "24.50",
            "BASEMENTS [M]": "2,880.00",
            "GF & PODIUM [N]": "14,400.00",
            "TOWER 1 [O]": "24,000.00",
            "TOWER 2 [P]": "26,400.00",
            "TOWER 3 [Q]": "24,960.00",
            "TOWER 4 [R]": "24,960.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-F",
          "item_code": "F",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Upstands; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Upstands; various diameter",
          "quantity": 40.08,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 192384,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 452
          },
          "extra_columns": {
            "Basement [C]": "6.48",
            "GF & Podium [D]": "1.08",
            "Tower 1 [E]": "8.28",
            "Tower 2 [F]": "7.56",
            "Tower 3 [G]": "6.24",
            "Tower 4 [H]": "10.44",
            "TOTAL QTY [I]": "40.08",
            "BASEMENTS [M]": "31,104.00",
            "GF & PODIUM [N]": "5,184.00",
            "TOWER 1 [O]": "39,744.00",
            "TOWER 2 [P]": "36,288.00",
            "TOWER 3 [Q]": "29,952.00",
            "TOWER 4 [R]": "50,112.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-G",
          "item_code": "G",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Downstands; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Downstands; various diameter",
          "quantity": 12.36,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 59328,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 454
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "1.80",
            "Tower 1 [E]": "6.00",
            "Tower 2 [F]": "2.28",
            "Tower 3 [G]": "0.24",
            "Tower 4 [H]": "2.04",
            "TOTAL QTY [I]": "12.36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,640.00",
            "TOWER 1 [O]": "28,800.00",
            "TOWER 2 [P]": "10,944.00",
            "TOWER 3 [Q]": "1,152.00",
            "TOWER 4 [R]": "9,792.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-H",
          "item_code": "H",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Parapet; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Parapet; various diameter",
          "quantity": 5.4,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 25920,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 456
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.76",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "2.64",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "5.40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "13,248.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,672.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-J",
          "item_code": "J",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Staircase; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Staircase; various diameter",
          "quantity": 417.40000000000003,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 2003520.0000000002,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 458
          },
          "extra_columns": {
            "Basement [C]": "31.80",
            "GF & Podium [D]": "55.00",
            "Tower 1 [E]": "79.00",
            "Tower 2 [F]": "87.60",
            "Tower 3 [G]": "84.20",
            "Tower 4 [H]": "79.80",
            "TOTAL QTY [I]": "417.40",
            "BASEMENTS [M]": "152,640.00",
            "GF & PODIUM [N]": "264,000.00",
            "TOWER 1 [O]": "379,200.00",
            "TOWER 2 [P]": "420,480.00",
            "TOWER 3 [Q]": "404,160.00",
            "TOWER 4 [R]": "383,040.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-K",
          "item_code": "K",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "RC plinth; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — RC plinth; various diameter",
          "quantity": 14.76,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 70848,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 460
          },
          "extra_columns": {
            "Basement [C]": "1.32",
            "GF & Podium [D]": "2.16",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "4.68",
            "Tower 3 [G]": "3.60",
            "Tower 4 [H]": "3.00",
            "TOTAL QTY [I]": "14.76",
            "BASEMENTS [M]": "6,336.00",
            "GF & PODIUM [N]": "10,368.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "22,464.00",
            "TOWER 3 [Q]": "17,280.00",
            "TOWER 4 [R]": "14,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-L",
          "item_code": "L",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Core walls podium; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Core walls podium; various diameter",
          "quantity": 429.35,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 2060880,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 462
          },
          "extra_columns": {
            "Basement [C]": "195.76",
            "GF & Podium [D]": "233.59",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "429.35",
            "BASEMENTS [M]": "939,648.00",
            "GF & PODIUM [N]": "1,121,232.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-M",
          "item_code": "M",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Core walls tower; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Core walls tower; various diameter",
          "quantity": 12658.170000000002,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 60759216.00000001,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 464
          },
          "extra_columns": {
            "Basement [C]": "923.90",
            "GF & Podium [D]": "1,574.13",
            "Tower 1 [E]": "1,947.75",
            "Tower 2 [F]": "2,836.12",
            "Tower 3 [G]": "2,797.64",
            "Tower 4 [H]": "2,578.63",
            "TOTAL QTY [I]": "12,658.17",
            "BASEMENTS [M]": "4,434,720.00",
            "GF & PODIUM [N]": "7,555,824.00",
            "TOWER 1 [O]": "9,349,200.00",
            "TOWER 2 [P]": "13,613,376.00",
            "TOWER 3 [Q]": "13,428,672.00",
            "TOWER 4 [R]": "12,377,424.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-N",
          "item_code": "N",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Beams; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Beams; various diameter",
          "quantity": 1649.22,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 7916256,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 466
          },
          "extra_columns": {
            "Basement [C]": "107.25",
            "GF & Podium [D]": "907.70",
            "Tower 1 [E]": "180.21",
            "Tower 2 [F]": "71.34",
            "Tower 3 [G]": "186.77",
            "Tower 4 [H]": "195.95",
            "TOTAL QTY [I]": "1,649.22",
            "BASEMENTS [M]": "514,800.00",
            "GF & PODIUM [N]": "4,356,960.00",
            "TOWER 1 [O]": "865,008.00",
            "TOWER 2 [P]": "342,432.00",
            "TOWER 3 [Q]": "896,496.00",
            "TOWER 4 [R]": "940,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-P",
          "item_code": "P",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Drop panels; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Drop panels; various diameter",
          "quantity": 348.46999999999997,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 1672655.9999999998,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 468
          },
          "extra_columns": {
            "Basement [C]": "66.59",
            "GF & Podium [D]": "271.44",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "2.88",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "7.56",
            "TOTAL QTY [I]": "348.47",
            "BASEMENTS [M]": "319,632.00",
            "GF & PODIUM [N]": "1,302,912.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,824.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "36,288.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-Q",
          "item_code": "Q",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Pile caps; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Pile caps; various diameter",
          "quantity": 1266.8,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 6080640,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 470
          },
          "extra_columns": {
            "Basement [C]": "1,266.80",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "1,266.80",
            "BASEMENTS [M]": "6,080,640.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-R",
          "item_code": "R",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Coupling beams; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Coupling beams; various diameter",
          "quantity": 1278.73,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 6137904,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 472
          },
          "extra_columns": {
            "Basement [C]": "31.92",
            "GF & Podium [D]": "140.66",
            "Tower 1 [E]": "225.40",
            "Tower 2 [F]": "327.67",
            "Tower 3 [G]": "283.79",
            "Tower 4 [H]": "269.29",
            "TOTAL QTY [I]": "1,278.73",
            "BASEMENTS [M]": "153,216.00",
            "GF & PODIUM [N]": "675,168.00",
            "TOWER 1 [O]": "1,081,920.00",
            "TOWER 2 [P]": "1,572,816.00",
            "TOWER 3 [Q]": "1,362,192.00",
            "TOWER 4 [R]": "1,292,592.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-S",
          "item_code": "S",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Columns podium; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Columns podium; various diameter",
          "quantity": 765.88,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 3676224,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 474
          },
          "extra_columns": {
            "Basement [C]": "423.23",
            "GF & Podium [D]": "342.65",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "765.88",
            "BASEMENTS [M]": "2,031,504.00",
            "GF & PODIUM [N]": "1,644,720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-T",
          "item_code": "T",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Columns tower; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Columns tower; various diameter",
          "quantity": 1869.3,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 8972640,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 476
          },
          "extra_columns": {
            "Basement [C]": "129.58",
            "GF & Podium [D]": "221.34",
            "Tower 1 [E]": "319.30",
            "Tower 2 [F]": "407.34",
            "Tower 3 [G]": "403.31",
            "Tower 4 [H]": "388.43",
            "TOTAL QTY [I]": "1,869.30",
            "BASEMENTS [M]": "621,984.00",
            "GF & PODIUM [N]": "1,062,432.00",
            "TOWER 1 [O]": "1,532,640.00",
            "TOWER 2 [P]": "1,955,232.00",
            "TOWER 3 [Q]": "1,935,888.00",
            "TOWER 4 [R]": "1,864,464.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-U",
          "item_code": "U",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Blade walls podium; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Blade walls podium; various diameter",
          "quantity": 343.77,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 1650096,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 478
          },
          "extra_columns": {
            "Basement [C]": "222.18",
            "GF & Podium [D]": "121.59",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "343.77",
            "BASEMENTS [M]": "1,066,464.00",
            "GF & PODIUM [N]": "583,632.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-V",
          "item_code": "V",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Blade walls tower; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Blade walls tower; various diameter",
          "quantity": 4177.62,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 20052576,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 480
          },
          "extra_columns": {
            "Basement [C]": "254.73",
            "GF & Podium [D]": "1,007.46",
            "Tower 1 [E]": "731.79",
            "Tower 2 [F]": "709.47",
            "Tower 3 [G]": "675.17",
            "Tower 4 [H]": "799.00",
            "TOTAL QTY [I]": "4,177.62",
            "BASEMENTS [M]": "1,222,704.00",
            "GF & PODIUM [N]": "4,835,808.00",
            "TOWER 1 [O]": "3,512,592.00",
            "TOWER 2 [P]": "3,405,456.00",
            "TOWER 3 [Q]": "3,240,816.00",
            "TOWER 4 [R]": "3,835,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-W",
          "item_code": "W",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Pedestal; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Pedestal; various diameter",
          "quantity": 18,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 86400,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 482
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "5.75",
            "Tower 1 [E]": "3.25",
            "Tower 2 [F]": "2.50",
            "Tower 3 [G]": "3.25",
            "Tower 4 [H]": "3.25",
            "TOTAL QTY [I]": "18.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,600.00",
            "TOWER 1 [O]": "15,600.00",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "15,600.00",
            "TOWER 4 [R]": "15,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/8-X",
          "item_code": "X",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Ramps; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Ramps; various diameter",
          "quantity": 89,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 427200,
          "amount_state": "number",
          "printed_page": "2/C/5",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 484
          },
          "extra_columns": {
            "Basement [C]": "56.00",
            "GF & Podium [D]": "33.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "89.00",
            "BASEMENTS [M]": "268,800.00",
            "GF & PODIUM [N]": "158,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/9",
      "section": "REINFORCEMENT",
      "sheet": "2 - Main",
      "source_collection_aed": 1294933,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/9-A",
          "item_code": "A",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Water tank walls; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Water tank walls; various diameter",
          "quantity": 92.32,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 443135.99999999994,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 498
          },
          "extra_columns": {
            "Basement [C]": "84.80",
            "GF & Podium [D]": "7.52",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "92.32",
            "BASEMENTS [M]": "407,040.00",
            "GF & PODIUM [N]": "36,096.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/9-B",
          "item_code": "B",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Planter wall",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Planter wall",
          "quantity": 8.879999999999999,
          "unit": "t",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 500
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.28",
            "Tower 2 [F]": "2.16",
            "Tower 3 [G]": "2.28",
            "Tower 4 [H]": "2.16",
            "TOTAL QTY [I]": "8.88",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/9-C",
          "item_code": "C",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Sump pit wall; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Sump pit wall; various diameter",
          "quantity": 20.84,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 100032,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 502
          },
          "extra_columns": {
            "Basement [C]": "20.20",
            "GF & Podium [D]": "0.64",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "20.84",
            "BASEMENTS [M]": "96,960.00",
            "GF & PODIUM [N]": "3,072.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/9-D",
          "item_code": "D",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Sump pit floors; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Sump pit floors; various diameter",
          "quantity": 11,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 52800,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 504
          },
          "extra_columns": {
            "Basement [C]": "0.25",
            "GF & Podium [D]": "10.75",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "11.00",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "51,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/9-E",
          "item_code": "E",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Second cast walls, various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Second cast walls, various diameter",
          "quantity": 108,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 518400,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 506
          },
          "extra_columns": {
            "Basement [C]": "8.00",
            "GF & Podium [D]": "7.00",
            "Tower 1 [E]": "22.00",
            "Tower 2 [F]": "26.00",
            "Tower 3 [G]": "21.00",
            "Tower 4 [H]": "24.00",
            "TOTAL QTY [I]": "108.00",
            "BASEMENTS [M]": "38,400.00",
            "GF & PODIUM [N]": "33,600.00",
            "TOWER 1 [O]": "105,600.00",
            "TOWER 2 [P]": "124,800.00",
            "TOWER 3 [Q]": "100,800.00",
            "TOWER 4 [R]": "115,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/9-F",
          "item_code": "F",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Mesh reinforcement; including accessories and all ancillary works as necessary"
          ],
          "own_description": "A252; single later; to light weight fill",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — REINFORCEMENT — Mesh reinforcement; including accessories and all ancillary works as necessary — A252; single later; to light weight fill",
          "quantity": 5159,
          "unit": "m2",
          "rate_aed": 35,
          "amount_aed": 180565,
          "amount_state": "number",
          "printed_page": "2/C/6",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 510
          },
          "extra_columns": {
            "Basement [C]": "974",
            "GF & Podium [D]": "3,793",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "139",
            "Tower 3 [G]": "94",
            "Tower 4 [H]": "150",
            "TOTAL QTY [I]": "5,159",
            "BASEMENTS [M]": "34,090.00",
            "GF & PODIUM [N]": "132,755.00",
            "TOWER 1 [O]": "315.00",
            "TOWER 2 [P]": "4,865.00",
            "TOWER 3 [Q]": "3,290.00",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/10",
      "section": "SHUTTERING",
      "sheet": "2 - Main",
      "source_collection_aed": 78131625,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/10-A",
          "item_code": "A",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Soffit of suspended slab; including edges",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Soffit of suspended slab; including edges",
          "quantity": 111983,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 15677620,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 557
          },
          "extra_columns": {
            "Basement [C]": "27,528",
            "GF & Podium [D]": "42,628",
            "Tower 1 [E]": "8,972",
            "Tower 2 [F]": "13,545",
            "Tower 3 [G]": "9,178",
            "Tower 4 [H]": "10,132",
            "TOTAL QTY [I]": "111,983",
            "BASEMENTS [M]": "3,853,920.00",
            "GF & PODIUM [N]": "5,967,920.00",
            "TOWER 1 [O]": "1,256,080.00",
            "TOWER 2 [P]": "1,896,300.00",
            "TOWER 3 [Q]": "1,284,920.00",
            "TOWER 4 [R]": "1,418,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-B",
          "item_code": "B",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of slab on grade",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of slab on grade",
          "quantity": null,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-C",
          "item_code": "C",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of basement walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of basement walls",
          "quantity": 12965,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 1815100,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 561
          },
          "extra_columns": {
            "Basement [C]": "12,965",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12,965",
            "BASEMENTS [M]": "1,815,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-D",
          "item_code": "D",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of raft foundations",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of raft foundations",
          "quantity": 15265,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 2137100,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 563
          },
          "extra_columns": {
            "Basement [C]": "15,265",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15,265",
            "BASEMENTS [M]": "2,137,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-E",
          "item_code": "E",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Soffit of ramp slab; including edges",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Soffit of ramp slab; including edges",
          "quantity": 1924,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 288600,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 565
          },
          "extra_columns": {
            "Basement [C]": "1,210",
            "GF & Podium [D]": "714",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,924",
            "BASEMENTS [M]": "181,500.00",
            "GF & PODIUM [N]": "107,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-F",
          "item_code": "F",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides and soffits of lintel beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides and soffits of lintel beams",
          "quantity": 3782,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 567300,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 567
          },
          "extra_columns": {
            "Basement [C]": "95",
            "GF & Podium [D]": "455",
            "Tower 1 [E]": "685",
            "Tower 2 [F]": "883",
            "Tower 3 [G]": "834",
            "Tower 4 [H]": "830",
            "TOTAL QTY [I]": "3,782",
            "BASEMENTS [M]": "14,250.00",
            "GF & PODIUM [N]": "68,250.00",
            "TOWER 1 [O]": "102,750.00",
            "TOWER 2 [P]": "132,450.00",
            "TOWER 3 [Q]": "125,100.00",
            "TOWER 4 [R]": "124,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-G",
          "item_code": "G",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of upstands",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of upstands",
          "quantity": 3342,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 518010,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 569
          },
          "extra_columns": {
            "Basement [C]": "348",
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "709",
            "Tower 2 [F]": "696",
            "Tower 3 [G]": "566",
            "Tower 4 [H]": "920",
            "TOTAL QTY [I]": "3,342",
            "BASEMENTS [M]": "53,940.00",
            "GF & PODIUM [N]": "15,965.00",
            "TOWER 1 [O]": "109,895.00",
            "TOWER 2 [P]": "107,880.00",
            "TOWER 3 [Q]": "87,730.00",
            "TOWER 4 [R]": "142,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-H",
          "item_code": "H",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of downstand",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of downstand",
          "quantity": 1026,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 159030,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 571
          },
          "extra_columns": {
            "GF & Podium [D]": "267",
            "Tower 1 [E]": "378",
            "Tower 2 [F]": "189",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "173",
            "TOTAL QTY [I]": "1,026",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "41,385.00",
            "TOWER 1 [O]": "58,590.00",
            "TOWER 2 [P]": "29,295.00",
            "TOWER 3 [Q]": "2,945.00",
            "TOWER 4 [R]": "26,815.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-J",
          "item_code": "J",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of parapet",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of parapet",
          "quantity": 454,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 70370,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "239",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "215",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "454",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "37,045.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "33,325.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-K",
          "item_code": "K",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides and soffits of staircase",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides and soffits of staircase",
          "quantity": 7423,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 1150565,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 575
          },
          "extra_columns": {
            "Basement [C]": "912",
            "GF & Podium [D]": "1,572",
            "Tower 1 [E]": "1,532",
            "Tower 2 [F]": "1,700",
            "Tower 3 [G]": "878",
            "Tower 4 [H]": "829",
            "TOTAL QTY [I]": "7,423",
            "BASEMENTS [M]": "141,360.00",
            "GF & PODIUM [N]": "243,660.00",
            "TOWER 1 [O]": "237,460.00",
            "TOWER 2 [P]": "263,500.00",
            "TOWER 3 [Q]": "136,090.00",
            "TOWER 4 [R]": "128,495.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-L",
          "item_code": "L",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of plinths",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of plinths",
          "quantity": 878,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 122920,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 577
          },
          "extra_columns": {
            "Basement [C]": "56",
            "GF & Podium [D]": "176",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "267",
            "Tower 3 [G]": "205",
            "Tower 4 [H]": "174",
            "TOTAL QTY [I]": "878",
            "BASEMENTS [M]": "7,840.00",
            "GF & PODIUM [N]": "24,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "37,380.00",
            "TOWER 3 [Q]": "28,700.00",
            "TOWER 4 [R]": "24,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-M",
          "item_code": "M",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of columns",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of columns",
          "quantity": 43746,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 6124440,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 579
          },
          "extra_columns": {
            "Basement [C]": "10,711",
            "GF & Podium [D]": "10,276",
            "Tower 1 [E]": "4,863",
            "Tower 2 [F]": "6,230",
            "Tower 3 [G]": "5,807",
            "Tower 4 [H]": "5,859",
            "TOTAL QTY [I]": "43,746",
            "BASEMENTS [M]": "1,499,540.00",
            "GF & PODIUM [N]": "1,438,640.00",
            "TOWER 1 [O]": "680,820.00",
            "TOWER 2 [P]": "872,200.00",
            "TOWER 3 [Q]": "812,980.00",
            "TOWER 4 [R]": "820,260.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-N",
          "item_code": "N",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of core walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of core walls",
          "quantity": 253660,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 35512400,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 581
          },
          "extra_columns": {
            "Basement [C]": "17,770",
            "GF & Podium [D]": "41,608",
            "Tower 1 [E]": "41,464",
            "Tower 2 [F]": "53,954",
            "Tower 3 [G]": "50,744",
            "Tower 4 [H]": "48,120",
            "TOTAL QTY [I]": "253,660",
            "BASEMENTS [M]": "2,487,800.00",
            "GF & PODIUM [N]": "5,825,120.00",
            "TOWER 1 [O]": "5,804,960.00",
            "TOWER 2 [P]": "7,553,560.00",
            "TOWER 3 [Q]": "7,104,160.00",
            "TOWER 4 [R]": "6,736,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-P",
          "item_code": "P",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides and soffits of beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides and soffits of beams",
          "quantity": 25923,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 4018065,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 583
          },
          "extra_columns": {
            "Basement [C]": "1,570",
            "GF & Podium [D]": "11,654",
            "Tower 1 [E]": "2,795",
            "Tower 2 [F]": "3,608",
            "Tower 3 [G]": "2,950",
            "Tower 4 [H]": "3,346",
            "TOTAL QTY [I]": "25,923",
            "BASEMENTS [M]": "243,350.00",
            "GF & PODIUM [N]": "1,806,370.00",
            "TOWER 1 [O]": "433,225.00",
            "TOWER 2 [P]": "559,240.00",
            "TOWER 3 [Q]": "457,250.00",
            "TOWER 4 [R]": "518,630.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-Q",
          "item_code": "Q",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides and soffits drop panels",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides and soffits drop panels",
          "quantity": 4727,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 732685,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 585
          },
          "extra_columns": {
            "Basement [C]": "1,133",
            "GF & Podium [D]": "3,425",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "119",
            "TOTAL QTY [I]": "4,727",
            "BASEMENTS [M]": "175,615.00",
            "GF & PODIUM [N]": "530,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "18,445.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-R",
          "item_code": "R",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of pile caps",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of pile caps",
          "quantity": 5289,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 740460,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 587
          },
          "extra_columns": {
            "Basement [C]": "5,289",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5,289",
            "BASEMENTS [M]": "740,460.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-S",
          "item_code": "S",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides and soffits of coupling beams",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides and soffits of coupling beams",
          "quantity": 12344,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 1913320,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 589
          },
          "extra_columns": {
            "Basement [C]": "298",
            "GF & Podium [D]": "1,618",
            "Tower 1 [E]": "2,314",
            "Tower 2 [F]": "2,867",
            "Tower 3 [G]": "2,674",
            "Tower 4 [H]": "2,573",
            "TOTAL QTY [I]": "12,344",
            "BASEMENTS [M]": "46,190.00",
            "GF & PODIUM [N]": "250,790.00",
            "TOWER 1 [O]": "358,670.00",
            "TOWER 2 [P]": "444,385.00",
            "TOWER 3 [Q]": "414,470.00",
            "TOWER 4 [R]": "398,815.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-T",
          "item_code": "T",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of blade walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of blade walls",
          "quantity": 45395,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 6355300,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 591
          },
          "extra_columns": {
            "Basement [C]": "4,285",
            "GF & Podium [D]": "16,297",
            "Tower 1 [E]": "6,228",
            "Tower 2 [F]": "6,038",
            "Tower 3 [G]": "5,746",
            "Tower 4 [H]": "6,801",
            "TOTAL QTY [I]": "45,395",
            "BASEMENTS [M]": "599,900.00",
            "GF & PODIUM [N]": "2,281,580.00",
            "TOWER 1 [O]": "871,920.00",
            "TOWER 2 [P]": "845,320.00",
            "TOWER 3 [Q]": "804,440.00",
            "TOWER 4 [R]": "952,140.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-U",
          "item_code": "U",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of pedestal",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of pedestal",
          "quantity": 255,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 35700,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "91",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "34",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "255",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,740.00",
            "TOWER 1 [O]": "6,020.00",
            "TOWER 2 [P]": "4,760.00",
            "TOWER 3 [Q]": "6,160.00",
            "TOWER 4 [R]": "6,020.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/10-V",
          "item_code": "V",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Soffit of suspended pool slab",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Soffit of suspended pool slab",
          "quantity": 1376,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 192640,
          "amount_state": "number",
          "printed_page": "2/C/7",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,123",
            "Tower 1 [E]": "69",
            "Tower 2 [F]": "62",
            "Tower 3 [G]": "60",
            "Tower 4 [H]": "62",
            "TOTAL QTY [I]": "1,376",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "157,220.00",
            "TOWER 1 [O]": "9,660.00",
            "TOWER 2 [P]": "8,680.00",
            "TOWER 3 [Q]": "8,400.00",
            "TOWER 4 [R]": "8,680.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/11",
      "section": "SHUTTERING",
      "sheet": "2 - Main",
      "source_collection_aed": 1865920,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/11-A",
          "item_code": "A",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of water tank walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of water tank walls",
          "quantity": 2548,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 356720,
          "amount_state": "number",
          "printed_page": "2/C/8",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 611
          },
          "extra_columns": {
            "Basement [C]": "2,454",
            "GF & Podium [D]": "94",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,548",
            "BASEMENTS [M]": "343,560.00",
            "GF & PODIUM [N]": "13,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/11-B",
          "item_code": "B",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of sump pit walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of sump pit walls",
          "quantity": 495,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 69300,
          "amount_state": "number",
          "printed_page": "2/C/8",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 613
          },
          "extra_columns": {
            "Basement [C]": "495",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "495",
            "BASEMENTS [M]": "69,300.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/11-C",
          "item_code": "C",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of sump pit floor",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of sump pit floor",
          "quantity": 13,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 1820,
          "amount_state": "number",
          "printed_page": "2/C/8",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "140.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/11-D",
          "item_code": "D",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sides of second cast walls",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Sides of second cast walls",
          "quantity": 10272,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 1438080,
          "amount_state": "number",
          "printed_page": "2/C/8",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 617
          },
          "extra_columns": {
            "Basement [C]": "718",
            "GF & Podium [D]": "686",
            "Tower 1 [E]": "2,096",
            "Tower 2 [F]": "2,441",
            "Tower 3 [G]": "2,048",
            "Tower 4 [H]": "2,283",
            "TOTAL QTY [I]": "10,272",
            "BASEMENTS [M]": "100,520.00",
            "GF & PODIUM [N]": "96,040.00",
            "TOWER 1 [O]": "293,440.00",
            "TOWER 2 [P]": "341,740.00",
            "TOWER 3 [Q]": "286,720.00",
            "TOWER 4 [R]": "319,620.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/12",
      "section": "PRESTRESSED CONCRETE",
      "sheet": "2 - Main",
      "source_collection_aed": 104349826,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/12-A",
          "item_code": "A",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "PT slabs; various thickness",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Reinforced concrete; concrete grade C50/60 — PT slabs; various thickness",
          "quantity": 52988,
          "unit": "m3",
          "rate_aed": 530,
          "amount_aed": 28083640,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6,954",
            "Tower 1 [E]": "10,722",
            "Tower 2 [F]": "12,019",
            "Tower 3 [G]": "11,969",
            "Tower 4 [H]": "11,324",
            "TOTAL QTY [I]": "52,988",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,685,620.00",
            "TOWER 1 [O]": "5,682,660.00",
            "TOWER 2 [P]": "6,370,070.00",
            "TOWER 3 [Q]": "6,343,570.00",
            "TOWER 4 [R]": "6,001,720.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-B",
          "item_code": "B",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary"
          ],
          "own_description": "Edges and soffit of PT slabs",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Edges and soffit of PT slabs",
          "quantity": 272894,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 40934100,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34,936",
            "Tower 1 [E]": "57,219",
            "Tower 2 [F]": "60,518",
            "Tower 3 [G]": "62,103",
            "Tower 4 [H]": "58,118",
            "TOTAL QTY [I]": "272,894",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,240,400.00",
            "TOWER 1 [O]": "8,582,850.00",
            "TOWER 2 [P]": "9,077,700.00",
            "TOWER 3 [Q]": "9,315,450.00",
            "TOWER 4 [R]": "8,717,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-C",
          "item_code": "C",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Passive reinforcement; to post tensioned slabs; various diameter",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Reinforcing steel bars; high yield deformed; grade 60 — Passive reinforcement; to post tensioned slabs; various diameter",
          "quantity": 3709.16,
          "unit": "t",
          "rate_aed": 4600,
          "amount_aed": 17062136,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 678
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "486.78",
            "Tower 1 [E]": "750.54",
            "Tower 2 [F]": "841.33",
            "Tower 3 [G]": "837.83",
            "Tower 4 [H]": "792.68",
            "TOTAL QTY [I]": "3,709.16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,239,188.00",
            "TOWER 1 [O]": "3,452,484.00",
            "TOWER 2 [P]": "3,870,118.00",
            "TOWER 3 [Q]": "3,854,018.00",
            "TOWER 4 [R]": "3,646,328.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-D",
          "item_code": "D",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Post tensioning (PT) system; comprise of design, approvals including prestressing steel, anchorages, plates, ducts, grouts, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "PT system; to post tensioned slab",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Post tensioning (PT) system; comprise of design, approvals including prestressing steel, anchorages, plates, ducts, grouts, protection, accessories and all ancillary works as necessary — PT system; to post tensioned slab",
          "quantity": 237615,
          "unit": "m2",
          "rate_aed": 65,
          "amount_aed": 15444975,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 682
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "32,546.00",
            "Tower 1 [E]": "48,924.00",
            "Tower 2 [F]": "53,170.00",
            "Tower 3 [G]": "51,671.00",
            "Tower 4 [H]": "51,304.00",
            "TOTAL QTY [I]": "237,615.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,115,490.00",
            "TOWER 1 [O]": "3,180,060.00",
            "TOWER 2 [P]": "3,456,050.00",
            "TOWER 3 [Q]": "3,358,615.00",
            "TOWER 4 [R]": "3,334,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-E",
          "item_code": "E",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "20mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 20mm thick",
          "quantity": 0.47,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 5405,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 686
          },
          "extra_columns": {
            "GF & Podium [D]": "0.47",
            "TOTAL QTY [I]": "0.47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,405.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-F",
          "item_code": "F",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "25mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 25mm thick",
          "quantity": 1,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 11500,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 688
          },
          "extra_columns": {
            "Tower 2 [F]": "1.00",
            "TOTAL QTY [I]": "1.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-G",
          "item_code": "G",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "30mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 30mm thick",
          "quantity": 128.05999999999997,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 1472689.9999999998,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 690
          },
          "extra_columns": {
            "Basement [C]": "0.73",
            "GF & Podium [D]": "13.87",
            "Tower 1 [E]": "24.27",
            "Tower 2 [F]": "35.36",
            "Tower 3 [G]": "23.99",
            "Tower 4 [H]": "29.84",
            "TOTAL QTY [I]": "128.06",
            "BASEMENTS [M]": "8,395.00",
            "GF & PODIUM [N]": "159,505.00",
            "TOWER 1 [O]": "279,105.00",
            "TOWER 2 [P]": "406,640.00",
            "TOWER 3 [Q]": "275,885.00",
            "TOWER 4 [R]": "343,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-H",
          "item_code": "H",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "35mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 35mm thick",
          "quantity": 2.26,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 25989.999999999996,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 692
          },
          "extra_columns": {
            "GF & Podium [D]": "0.27",
            "Tower 1 [E]": "0.28",
            "Tower 2 [F]": "0.72",
            "Tower 3 [G]": "0.71",
            "Tower 4 [H]": "0.28",
            "TOTAL QTY [I]": "2.26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,105.00",
            "TOWER 1 [O]": "3,220.00",
            "TOWER 2 [P]": "8,280.00",
            "TOWER 3 [Q]": "8,165.00",
            "TOWER 4 [R]": "3,220.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-J",
          "item_code": "J",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "40mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 40mm thick",
          "quantity": 18.189999999999998,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 209184.99999999997,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 694
          },
          "extra_columns": {
            "Tower 1 [E]": "1.62",
            "Tower 2 [F]": "4.14",
            "Tower 3 [G]": "8.29",
            "Tower 4 [H]": "4.14",
            "TOTAL QTY [I]": "18.19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,630.00",
            "TOWER 2 [P]": "47,610.00",
            "TOWER 3 [Q]": "95,335.00",
            "TOWER 4 [R]": "47,610.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-K",
          "item_code": "K",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "45mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 45mm thick",
          "quantity": 3.28,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 37720,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 696
          },
          "extra_columns": {
            "Tower 1 [E]": "3.28",
            "TOTAL QTY [I]": "3.28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "37,720.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-L",
          "item_code": "L",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "50mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 50mm thick",
          "quantity": 16.4,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 188599.99999999997,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 698
          },
          "extra_columns": {
            "GF & Podium [D]": "9.95",
            "Tower 1 [E]": "5.64",
            "Tower 2 [F]": "0.27",
            "Tower 3 [G]": "0.54",
            "TOTAL QTY [I]": "16.40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "114,425.00",
            "TOWER 1 [O]": "64,860.00",
            "TOWER 2 [P]": "3,105.00",
            "TOWER 3 [Q]": "6,210.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-M",
          "item_code": "M",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "55mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 55mm thick",
          "quantity": 47.46,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 545790,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 700
          },
          "extra_columns": {
            "GF & Podium [D]": "0.78",
            "Tower 2 [F]": "15.63",
            "Tower 3 [G]": "17.19",
            "Tower 4 [H]": "13.86",
            "TOTAL QTY [I]": "47.46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "179,745.00",
            "TOWER 3 [Q]": "197,685.00",
            "TOWER 4 [R]": "159,390.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-N",
          "item_code": "N",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "60mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 60mm thick",
          "quantity": 23.42,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 269330,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 702
          },
          "extra_columns": {
            "GF & Podium [D]": "1.49",
            "Tower 2 [F]": "6.82",
            "Tower 3 [G]": "7.96",
            "Tower 4 [H]": "7.15",
            "TOTAL QTY [I]": "23.42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,135.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "78,430.00",
            "TOWER 3 [Q]": "91,540.00",
            "TOWER 4 [R]": "82,225.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/12-P",
          "item_code": "P",
          "section": "PRESTRESSED CONCRETE",
          "heading_path": [
            "Steel Plate embedded in coupling beam and all ancillary works as necessary"
          ],
          "own_description": "70mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — PRESTRESSED CONCRETE — Steel Plate embedded in coupling beam and all ancillary works as necessary — 70mm thick",
          "quantity": 5.109999999999999,
          "unit": "t",
          "rate_aed": 11500,
          "amount_aed": 58764.99999999999,
          "amount_state": "number",
          "printed_page": "2/C/9",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 704
          },
          "extra_columns": {
            "GF & Podium [D]": "4.41",
            "Tower 3 [G]": "0.35",
            "Tower 4 [H]": "0.35",
            "TOTAL QTY [I]": "5.11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,715.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,025.00",
            "TOWER 4 [R]": "4,025.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/13",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 2986640,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/13-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [
            "Gunite concrete; including protection and reinforcement (both measured separately), compressible filler with sealant, accessories, and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — Gunite concrete; including protection and reinforcement (both measured separately), compressible filler with sealant, accessories, and all ancillary works as necessary — 100mm thick",
          "quantity": 98,
          "unit": "m3",
          "rate_aed": 330,
          "amount_aed": 32340,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 722
          },
          "extra_columns": {
            "Basement [C]": "98",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "32,340.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/13-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [
            "Gunite concrete; including protection and reinforcement (both measured separately), compressible filler with sealant, accessories, and all ancillary works as necessary"
          ],
          "own_description": "100mm thick; to shoring",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — Gunite concrete; including protection and reinforcement (both measured separately), compressible filler with sealant, accessories, and all ancillary works as necessary — 100mm thick; to shoring",
          "quantity": 733,
          "unit": "m3",
          "rate_aed": 330,
          "amount_aed": 241890,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 724
          },
          "extra_columns": {
            "Basement [C]": "733",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "733",
            "BASEMENTS [M]": "241,890.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/13-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [
            "Floating slab; including reinforcement, 40mm thick compressible joint filler, isolation board (to be measured separately), sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick (min)",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — Floating slab; including reinforcement, 40mm thick compressible joint filler, isolation board (to be measured separately), sealant, accessories and all ancillary works as necessary — 200mm thick (min)",
          "quantity": 461,
          "unit": "m2",
          "rate_aed": 160,
          "amount_aed": 73760,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 728
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "159",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "81",
            "Tower 3 [G]": "95",
            "Tower 4 [H]": "99",
            "TOTAL QTY [I]": "461",
            "BASEMENTS [M]": "4,320.00",
            "GF & PODIUM [N]": "25,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,960.00",
            "TOWER 3 [Q]": "15,200.00",
            "TOWER 4 [R]": "15,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/13-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [
            "Light weight concrete fill; with maximum density of 10kN/m³; including concrete screed (measured separately), accessories, and all ancillary works as necessary"
          ],
          "own_description": "To make-up levels; various thickness",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — Light weight concrete fill; with maximum density of 10kN/m³; including concrete screed (measured separately), accessories, and all ancillary works as necessary — To make-up levels; various thickness",
          "quantity": 1700,
          "unit": "m3",
          "rate_aed": 400,
          "amount_aed": 680000,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 732
          },
          "extra_columns": {
            "Basement [C]": "422",
            "GF & Podium [D]": "1,278",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,700",
            "BASEMENTS [M]": "168,800.00",
            "GF & PODIUM [N]": "511,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/13-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [
            "Dense structural screed; including accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick; to light weight concrete fill",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — Dense structural screed; including accessories and all ancillary works as necessary — 100mm thick; to light weight concrete fill",
          "quantity": 5159,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 1805650,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 736
          },
          "extra_columns": {
            "Basement [C]": "974",
            "GF & Podium [D]": "3,793",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "139",
            "Tower 3 [G]": "94",
            "Tower 4 [H]": "150",
            "TOTAL QTY [I]": "5,159",
            "BASEMENTS [M]": "340,900.00",
            "GF & PODIUM [N]": "1,327,550.00",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "48,650.00",
            "TOWER 3 [Q]": "32,900.00",
            "TOWER 4 [R]": "52,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/13-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [
            "25mm wide Isolation joint to slab on grade including 20mm diameter stainless steel dowel bars 800mm long at 300 spacing, preformed pvc or rubber close fitting dowel sleeve plug with foam filler, 25x25 deep approved joint sealant, 25mm thick compressible filler board and all ancillary works as necessary"
          ],
          "own_description": "To Ground Floor",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — SUNDRIES — 25mm wide Isolation joint to slab on grade including 20mm diameter stainless steel dowel bars 800mm long at 300 spacing, preformed pvc or rubber close fitting dowel sleeve plug with foam filler, 25x25 deep approved joint sealant, 25mm thick compressible filler board and all ancillary works as necessary — To Ground Floor",
          "quantity": 102,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 153000,
          "amount_state": "number",
          "printed_page": "2/C/10",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 740
          },
          "extra_columns": {
            "GF & Podium [D]": "102.00",
            "TOTAL QTY [I]": "102",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "153,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/14",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/14-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Concrete Work in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION C - CONCRETE WORKS (2/C) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Concrete Work in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/C/11",
          "bill_ref": "2",
          "section_ref": "2/C",
          "source": {
            "sheet": "2 - Main",
            "row": 764
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/15",
      "section": "WALL AND PIERS",
      "sheet": "2 - Main",
      "source_collection_aed": 37136250,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/15-A",
          "item_code": "A",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Internal blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "300mm thick; 2100kg/m³; 65 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Internal blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 300mm thick; 2100kg/m³; 65 Rw",
          "quantity": 1015,
          "unit": "m2",
          "rate_aed": 230,
          "amount_aed": 233450,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "358",
            "Tower 1 [E]": "125",
            "Tower 2 [F]": "224",
            "Tower 3 [G]": "150",
            "Tower 4 [H]": "158",
            "TOTAL QTY [I]": "1,015",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "82,340.00",
            "TOWER 1 [O]": "28,750.00",
            "TOWER 2 [P]": "51,520.00",
            "TOWER 3 [Q]": "34,500.00",
            "TOWER 4 [R]": "36,340.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-B",
          "item_code": "B",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Internal blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick; 2100kg/m³; 55 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Internal blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mm thick; 2100kg/m³; 55 Rw",
          "quantity": 71900,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 14380000,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 885
          },
          "extra_columns": {
            "Basement [C]": "1,455",
            "GF & Podium [D]": "9,095",
            "Tower 1 [E]": "13,278",
            "Tower 2 [F]": "15,266",
            "Tower 3 [G]": "16,578",
            "Tower 4 [H]": "16,228",
            "TOTAL QTY [I]": "71,900",
            "BASEMENTS [M]": "291,000.00",
            "GF & PODIUM [N]": "1,819,000.00",
            "TOWER 1 [O]": "2,655,600.00",
            "TOWER 2 [P]": "3,053,200.00",
            "TOWER 3 [Q]": "3,315,600.00",
            "TOWER 4 [R]": "3,245,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-C",
          "item_code": "C",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Internal blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mmthick; 1400kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Internal blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mmthick; 1400kg/m³; 50 Rw",
          "quantity": 17465,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 3493000,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "940",
            "Tower 1 [E]": "3,946",
            "Tower 2 [F]": "4,314",
            "Tower 3 [G]": "4,305",
            "Tower 4 [H]": "3,960",
            "TOTAL QTY [I]": "17,465",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "188,000.00",
            "TOWER 1 [O]": "789,200.00",
            "TOWER 2 [P]": "862,800.00",
            "TOWER 3 [Q]": "861,000.00",
            "TOWER 4 [R]": "792,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-D",
          "item_code": "D",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Internal blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mmthick; 2100kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Internal blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 150mmthick; 2100kg/m³; 50 Rw",
          "quantity": 83940,
          "unit": "m2",
          "rate_aed": 180,
          "amount_aed": 15109200,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 889
          },
          "extra_columns": {
            "Basement [C]": "1,364",
            "GF & Podium [D]": "4,954",
            "Tower 1 [E]": "17,741",
            "Tower 2 [F]": "21,491",
            "Tower 3 [G]": "19,470",
            "Tower 4 [H]": "18,920",
            "TOTAL QTY [I]": "83,940",
            "BASEMENTS [M]": "245,520.00",
            "GF & PODIUM [N]": "891,720.00",
            "TOWER 1 [O]": "3,193,380.00",
            "TOWER 2 [P]": "3,868,380.00",
            "TOWER 3 [Q]": "3,504,600.00",
            "TOWER 4 [R]": "3,405,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-E",
          "item_code": "E",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Internal blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mmthick; 1400kg/m³; 45 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Internal blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 100mmthick; 1400kg/m³; 45 Rw",
          "quantity": 3600,
          "unit": "m2",
          "rate_aed": 180,
          "amount_aed": 648000,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 891
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "311",
            "Tower 1 [E]": "1,337",
            "Tower 2 [F]": "136",
            "Tower 3 [G]": "1,028",
            "Tower 4 [H]": "788",
            "TOTAL QTY [I]": "3,600",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "55,980.00",
            "TOWER 1 [O]": "240,660.00",
            "TOWER 2 [P]": "24,480.00",
            "TOWER 3 [Q]": "185,040.00",
            "TOWER 4 [R]": "141,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-F",
          "item_code": "F",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick; 1600kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mm thick; 1600kg/m³; 50 Rw",
          "quantity": 5024,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 1004800,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 895
          },
          "extra_columns": {
            "Basement [C]": "831",
            "GF & Podium [D]": "4,193",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5,024",
            "BASEMENTS [M]": "166,200.00",
            "GF & PODIUM [N]": "838,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-G",
          "item_code": "G",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "300mm thick; 1600kg/m³; 60 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 300mm thick; 1600kg/m³; 60 Rw",
          "quantity": 488,
          "unit": "m2",
          "rate_aed": 230,
          "amount_aed": 112240,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "488",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "488",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "112,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-H",
          "item_code": "H",
          "section": "WALL AND PIERS",
          "heading_path": [
            "External blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick; 2100kg/m³; 55 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — External blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mm thick; 2100kg/m³; 55 Rw",
          "quantity": 10504,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 2100800,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 903
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "213",
            "Tower 1 [E]": "2,606",
            "Tower 2 [F]": "2,586",
            "Tower 3 [G]": "2,782",
            "Tower 4 [H]": "2,317",
            "TOTAL QTY [I]": "10,504",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,600.00",
            "TOWER 1 [O]": "521,200.00",
            "TOWER 2 [P]": "517,200.00",
            "TOWER 3 [Q]": "556,400.00",
            "TOWER 4 [R]": "463,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-J",
          "item_code": "J",
          "section": "WALL AND PIERS",
          "heading_path": [
            "External blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mmthick; 1400kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — External blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mmthick; 1400kg/m³; 50 Rw",
          "quantity": 113,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 22600,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "83",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "30",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-K",
          "item_code": "K",
          "section": "WALL AND PIERS",
          "heading_path": [
            "External blockworks",
            "Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mmthick; 2100kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — External blockworks — Solid blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 150mmthick; 2100kg/m³; 50 Rw",
          "quantity": 52,
          "unit": "m2",
          "rate_aed": 180,
          "amount_aed": 9360,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/15-L",
          "item_code": "L",
          "section": "WALL AND PIERS",
          "heading_path": [
            "Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick; 1600kg/m³; 50 Rw",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — WALL AND PIERS — Thermal blockwall; including fire rating (FR), sound transmission class (STC), mortar, grout, stiffeners, reinforcement, ties, anchors, tie wires, metal flashings, accessories and all ancillary works as necessary — 200mm thick; 1600kg/m³; 50 Rw",
          "quantity": 114,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 22800,
          "amount_state": "number",
          "printed_page": "2/D/1",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "114",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/16",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/16-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [
            "Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like"
          ],
          "own_description": "Dowelled control joints",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — SUNDRIES — Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like — Dowelled control joints",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/D/2",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 927
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "Included",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/16-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [
            "Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like"
          ],
          "own_description": "Dowelled control joints (RATE ONLY)",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — SUNDRIES — Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like — Dowelled control joints (RATE ONLY)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Rate Only",
          "amount_state": "text",
          "printed_page": "2/D/2",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 929
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/16-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [
            "Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like"
          ],
          "own_description": "Isolation joints",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — SUNDRIES — Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like — Isolation joints",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/D/2",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 931
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "Included",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/16-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [
            "Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like"
          ],
          "own_description": "Isolation joints (RATE ONLY)",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — SUNDRIES — Joints in masonry; including fire resistant compressible joint filler, sealant, angle head restraints, telescopic, sleeved and/or debonded ties and the like — Isolation joints (RATE ONLY)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Rate Only",
          "amount_state": "text",
          "printed_page": "2/D/2",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 933
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/17",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/17-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Masonry in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION D - MASONRY (2/D) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Masonry in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/D/3",
          "bill_ref": "2",
          "section_ref": "2/D",
          "source": {
            "sheet": "2 - Main",
            "row": 981
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/18",
      "section": "STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 2664900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/18-A",
          "item_code": "A",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; CHS 76.1 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; CHS 76.1 x 5",
          "quantity": 3.99,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 59850,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1098
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.97",
            "Tower 2 [F]": "1.03",
            "Tower 3 [G]": "0.96",
            "Tower 4 [H]": "1.03",
            "TOTAL QTY [I]": "3.99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,550.00",
            "TOWER 2 [P]": "15,450.00",
            "TOWER 3 [Q]": "14,400.00",
            "TOWER 4 [R]": "15,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-B",
          "item_code": "B",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 100 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 100 x 5",
          "quantity": 10.68,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 160200,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1100
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.65",
            "Tower 2 [F]": "2.61",
            "Tower 3 [G]": "2.71",
            "Tower 4 [H]": "2.71",
            "TOTAL QTY [I]": "10.68",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "39,750.00",
            "TOWER 2 [P]": "39,150.00",
            "TOWER 3 [Q]": "40,650.00",
            "TOWER 4 [R]": "40,650.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-C",
          "item_code": "C",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 100 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 100 x 6.3",
          "quantity": 14.510000000000002,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 217650.00000000003,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1102
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "3.97",
            "Tower 2 [F]": "3.20",
            "Tower 3 [G]": "3.95",
            "Tower 4 [H]": "3.39",
            "TOTAL QTY [I]": "14.51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "59,550.00",
            "TOWER 2 [P]": "48,000.00",
            "TOWER 3 [Q]": "59,250.00",
            "TOWER 4 [R]": "50,850.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-D",
          "item_code": "D",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 120 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 120 x 6.3",
          "quantity": 10.45,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 156750,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1104
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.29",
            "Tower 2 [F]": "2.89",
            "Tower 3 [G]": "2.29",
            "Tower 4 [H]": "2.98",
            "TOTAL QTY [I]": "10.45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "34,350.00",
            "TOWER 2 [P]": "43,350.00",
            "TOWER 3 [Q]": "34,350.00",
            "TOWER 4 [R]": "44,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-E",
          "item_code": "E",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 120 x 8",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 120 x 8",
          "quantity": 0.36,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 5400,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1106
          },
          "extra_columns": {
            "Tower 2 [F]": "0.18",
            "Tower 4 [H]": "0.18",
            "TOTAL QTY [I]": "0.36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-F",
          "item_code": "F",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 150 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 150 x 5",
          "quantity": 1.33,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 19950,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1108
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.77",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.56",
            "TOTAL QTY [I]": "1.33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,550.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-G",
          "item_code": "G",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 200 x 150 x 8",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 200 x 150 x 8",
          "quantity": 20.82,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 312300,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1110
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "5.78",
            "Tower 2 [F]": "4.62",
            "Tower 3 [G]": "5.76",
            "Tower 4 [H]": "4.66",
            "TOTAL QTY [I]": "20.82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "86,700.00",
            "TOWER 2 [P]": "69,300.00",
            "TOWER 3 [Q]": "86,400.00",
            "TOWER 4 [R]": "69,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-H",
          "item_code": "H",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 250 x 150 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 250 x 150 x 6.3",
          "quantity": 1.62,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 24300,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1112
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.81",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "0.81",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "1.62",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-J",
          "item_code": "J",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 300 x 200 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 300 x 200 x 6.3",
          "quantity": 3.2199999999999998,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 48299.99999999999,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1114
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.78",
            "Tower 2 [F]": "0.83",
            "Tower 3 [G]": "0.78",
            "Tower 4 [H]": "0.83",
            "TOTAL QTY [I]": "3.22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,700.00",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "11,700.00",
            "TOWER 4 [R]": "12,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-K",
          "item_code": "K",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 350 x 250 x 8",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 350 x 250 x 8",
          "quantity": 3.78,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 56700,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1116
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "1.89",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "1.89",
            "TOTAL QTY [I]": "3.78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-L",
          "item_code": "L",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; RHS 450 x 250 x 8",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; RHS 450 x 250 x 8",
          "quantity": 5.52,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 82800,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1118
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "3.56",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "1.96",
            "TOTAL QTY [I]": "5.52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "53,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-M",
          "item_code": "M",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; UB 533 x 210 x 82",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; UB 533 x 210 x 82",
          "quantity": 61.95,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 929250,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1120
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "15.11",
            "Tower 2 [F]": "14.52",
            "Tower 3 [G]": "15.96",
            "Tower 4 [H]": "16.36",
            "TOTAL QTY [I]": "61.95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "226,650.00",
            "TOWER 2 [P]": "217,800.00",
            "TOWER 3 [Q]": "239,400.00",
            "TOWER 4 [R]": "245,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-N",
          "item_code": "N",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Beams; SHS 120 x 120 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Beams; SHS 120 x 120 x 6.3",
          "quantity": 8.27,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 124050,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1122
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.17",
            "Tower 2 [F]": "2.05",
            "Tower 3 [G]": "2.01",
            "Tower 4 [H]": "2.04",
            "TOTAL QTY [I]": "8.27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,550.00",
            "TOWER 2 [P]": "30,750.00",
            "TOWER 3 [Q]": "30,150.00",
            "TOWER 4 [R]": "30,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-P",
          "item_code": "P",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 76.1 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 76.1 x 5",
          "quantity": 2.3600000000000003,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 35400.00000000001,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1124
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.55",
            "Tower 2 [F]": "0.55",
            "Tower 3 [G]": "0.64",
            "Tower 4 [H]": "0.62",
            "TOTAL QTY [I]": "2.36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,250.00",
            "TOWER 2 [P]": "8,250.00",
            "TOWER 3 [Q]": "9,600.00",
            "TOWER 4 [R]": "9,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-Q",
          "item_code": "Q",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 88.9 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 88.9 x 5",
          "quantity": 6.36,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 95400,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1126
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "1.40",
            "Tower 2 [F]": "1.69",
            "Tower 3 [G]": "1.53",
            "Tower 4 [H]": "1.74",
            "TOTAL QTY [I]": "6.36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "21,000.00",
            "TOWER 2 [P]": "25,350.00",
            "TOWER 3 [Q]": "22,950.00",
            "TOWER 4 [R]": "26,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-R",
          "item_code": "R",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 88.9 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 88.9 x 6.3",
          "quantity": 11.73,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 175950,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1128
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "3.45",
            "Tower 2 [F]": "2.86",
            "Tower 3 [G]": "2.73",
            "Tower 4 [H]": "2.69",
            "TOTAL QTY [I]": "11.73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "51,750.00",
            "TOWER 2 [P]": "42,900.00",
            "TOWER 3 [Q]": "40,950.00",
            "TOWER 4 [R]": "40,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-S",
          "item_code": "S",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 114.3 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 114.3 x 5",
          "quantity": 6.2700000000000005,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 94050,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1130
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "1.60",
            "Tower 2 [F]": "1.60",
            "Tower 3 [G]": "1.60",
            "Tower 4 [H]": "1.47",
            "TOTAL QTY [I]": "6.27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,000.00",
            "TOWER 2 [P]": "24,000.00",
            "TOWER 3 [Q]": "24,000.00",
            "TOWER 4 [R]": "22,050.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-T",
          "item_code": "T",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 114.3 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 114.3 x 6.3",
          "quantity": 2.1500000000000004,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 32250.000000000004,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1132
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.68",
            "Tower 2 [F]": "0.56",
            "Tower 3 [G]": "0.35",
            "Tower 4 [H]": "0.56",
            "TOTAL QTY [I]": "2.15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,200.00",
            "TOWER 2 [P]": "8,400.00",
            "TOWER 3 [Q]": "5,250.00",
            "TOWER 4 [R]": "8,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/18-U",
          "item_code": "U",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bracings; CHS 139.7 x 5",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Bracings; CHS 139.7 x 5",
          "quantity": 2.29,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 34350,
          "amount_state": "number",
          "printed_page": "2/E/1",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1134
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.54",
            "Tower 2 [F]": "0.53",
            "Tower 3 [G]": "0.69",
            "Tower 4 [H]": "0.53",
            "TOTAL QTY [I]": "2.29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,100.00",
            "TOWER 2 [P]": "7,950.00",
            "TOWER 3 [Q]": "10,350.00",
            "TOWER 4 [R]": "7,950.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/19",
      "section": "STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 1736100,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/19-A",
          "item_code": "A",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Columns; UB 533 x 210 x 82",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Columns; UB 533 x 210 x 82",
          "quantity": 64.53,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 967950,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1151
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "16.26",
            "Tower 2 [F]": "18.58",
            "Tower 3 [G]": "17.65",
            "Tower 4 [H]": "12.04",
            "TOTAL QTY [I]": "64.53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "243,900.00",
            "TOWER 2 [P]": "278,700.00",
            "TOWER 3 [Q]": "264,750.00",
            "TOWER 4 [R]": "180,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/19-B",
          "item_code": "B",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Columns; UC 203 x 203 x 60",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Columns; UC 203 x 203 x 60",
          "quantity": 0.72,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1153
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.00",
            "Tower 2 [F]": "0.36",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.36",
            "TOTAL QTY [I]": "0.72",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/19-C",
          "item_code": "C",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Columns; CHS 219 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Columns; CHS 219 x 6.3",
          "quantity": 4.48,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 67200,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1155
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.24",
            "Tower 2 [F]": "0.00",
            "Tower 3 [G]": "2.24",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "4.48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "33,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "33,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/19-D",
          "item_code": "D",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Columns; SHS 150 x 150 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Columns; SHS 150 x 150 x 6.3",
          "quantity": 8.73,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 130950,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1157
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "2.42",
            "Tower 2 [F]": "1.96",
            "Tower 3 [G]": "2.41",
            "Tower 4 [H]": "1.94",
            "TOTAL QTY [I]": "8.73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "36,300.00",
            "TOWER 2 [P]": "29,400.00",
            "TOWER 3 [Q]": "36,150.00",
            "TOWER 4 [R]": "29,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/19-E",
          "item_code": "E",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Columns; SHS 120 x 120 x 6.3",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Structural steel frame; with grade S275/355; conforming to BS 5950 and BS EN 10025; including teflon, stiffeners, fixings, supports, surface treatment, protective coatings, accessories and all ancillary works as necessary — Columns; SHS 120 x 120 x 6.3",
          "quantity": 2.1799999999999997,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 32699.999999999996,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1159
          },
          "extra_columns": {
            "Basement [C]": "0.00",
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "0.58",
            "Tower 2 [F]": "0.60",
            "Tower 3 [G]": "0.42",
            "Tower 4 [H]": "0.58",
            "TOTAL QTY [I]": "2.18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,700.00",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "6,300.00",
            "TOWER 4 [R]": "8,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/19-F",
          "item_code": "F",
          "section": "STRUCTURAL METALWORK",
          "heading_path": [
            "Primary Structural Steel for Entrance Canopies & Canopies at crowns"
          ],
          "own_description": "At canopies",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — STRUCTURAL METALWORK — Primary Structural Steel for Entrance Canopies & Canopies at crowns — At canopies",
          "quantity": 35.099999999999994,
          "unit": "t",
          "rate_aed": 15000,
          "amount_aed": 526499.9999999999,
          "amount_state": "number",
          "printed_page": "2/E/2",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1163
          },
          "extra_columns": {
            "GF & Podium [D]": "17.86",
            "Tower 1 [E]": "4.52",
            "Tower 2 [F]": "4.10",
            "Tower 3 [G]": "4.52",
            "Tower 4 [H]": "4.10",
            "TOTAL QTY [I]": "35.10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "267,900.00",
            "TOWER 1 [O]": "67,800.00",
            "TOWER 2 [P]": "61,500.00",
            "TOWER 3 [Q]": "67,800.00",
            "TOWER 4 [R]": "61,500.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/20",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 97474280,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/20-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Glass Balustrades (BL-01); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm SGP interlayer + 10mm HS low iron clear glass with pvdf coated aluminium top trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "1200mm high; straight panels",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Glass Balustrades (BL-01); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm SGP interlayer + 10mm HS low iron clear glass with pvdf coated aluminium top trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — 1200mm high; straight panels",
          "quantity": 18857,
          "unit": "m",
          "rate_aed": 3190,
          "amount_aed": 60153830,
          "amount_state": "number",
          "printed_page": "2/E/3",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1210
          },
          "extra_columns": {
            "GF & Podium [D]": "663",
            "Tower 1 [E]": "2,199",
            "Tower 2 [F]": "7,012",
            "Tower 3 [G]": "2,471",
            "Tower 4 [H]": "6,512",
            "TOTAL QTY [I]": "18,857",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,114,970.00",
            "TOWER 1 [O]": "7,014,810.00",
            "TOWER 2 [P]": "22,368,280.00",
            "TOWER 3 [Q]": "7,882,490.00",
            "TOWER 4 [R]": "20,773,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/20-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Glass Balustrades (BL-01); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm SGP interlayer + 10mm HS low iron clear glass with pvdf coated aluminium top trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "1200mm high; curved panels",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Glass Balustrades (BL-01); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm SGP interlayer + 10mm HS low iron clear glass with pvdf coated aluminium top trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — 1200mm high; curved panels",
          "quantity": 7247,
          "unit": "m",
          "rate_aed": 4300,
          "amount_aed": 31162100,
          "amount_state": "number",
          "printed_page": "2/E/3",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1212
          },
          "extra_columns": {
            "GF & Podium [D]": "203",
            "Tower 1 [E]": "3,308",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3,736",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7,247",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "872,900.00",
            "TOWER 1 [O]": "14,224,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "16,064,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/20-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Privacy Partition (BL-02); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm milky SGB interlayer + 10mm HS low iron clear glass with pvdf coated aluminium edge protection trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "3100mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Privacy Partition (BL-02); to balcony areas; comprising of laminated 10mm HS low iron clear glass + 1.52mm milky SGB interlayer + 10mm HS low iron clear glass with pvdf coated aluminium edge protection trim: colour RAL 7043 (Tele Grey B: Matte finish), including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — 3100mm high",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 4650,
          "amount_aed": 88350,
          "amount_state": "number",
          "printed_page": "2/E/3",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1216
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "60,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/20-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Metal Balustrade including fixing and other accessories"
          ],
          "own_description": "1200mm high; to lift machine room walkway",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Metal Balustrade including fixing and other accessories — 1200mm high; to lift machine room walkway",
          "quantity": 68,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 81600,
          "amount_state": "number",
          "printed_page": "2/E/3",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1220
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "21",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "14",
            "TOTAL QTY [I]": "68",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,200.00",
            "TOWER 2 [P]": "22,800.00",
            "TOWER 3 [Q]": "16,800.00",
            "TOWER 4 [R]": "16,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/20-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Roof Feature (AL-21) comprising of 200x100mm C shaped aluminium extruded mullion and transom, solid core aluminum cladding and aluminum closure with polyester powder coated; colour RAL 050 50 10 \"Teakwood brown\" (Light brown) brushed smooth textured and mullion and transom colour: RAL 7043 (Tele grey B) matte finished; including brackets, fixings, fittings, accessories and all ancillary works as per facade drawings and specifications"
          ],
          "own_description": "To tower roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Roof Feature (AL-21) comprising of 200x100mm C shaped aluminium extruded mullion and transom, solid core aluminum cladding and aluminum closure with polyester powder coated; colour RAL 050 50 10 \"Teakwood brown\" (Light brown) brushed smooth textured and mullion and transom colour: RAL 7043 (Tele grey B) matte finished; including brackets, fixings, fittings, accessories and all ancillary works as per facade drawings and specifications — To tower roof",
          "quantity": 2722,
          "unit": "m2",
          "rate_aed": 2200,
          "amount_aed": 5988400,
          "amount_state": "number",
          "printed_page": "2/E/3",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1224
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "664",
            "Tower 2 [F]": "697",
            "Tower 3 [G]": "664",
            "Tower 4 [H]": "697",
            "TOTAL QTY [I]": "2,722",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,460,800.00",
            "TOWER 2 [P]": "1,533,400.00",
            "TOWER 3 [Q]": "1,460,800.00",
            "TOWER 4 [R]": "1,533,400.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/21",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 7698304.88,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/21-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium canopy coping; 1720mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium canopy coping; 1720mm girth",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 2000,
          "amount_aed": 66000,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1249
          },
          "extra_columns": {
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "66,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium canopy roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium canopy roof",
          "quantity": 63,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 76860,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1251
          },
          "extra_columns": {
            "GF & Podium [D]": "63",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "76,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 460mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 460mm girth",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1253
          },
          "extra_columns": {
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 950mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 950mm girth",
          "quantity": 235,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 235000,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1255
          },
          "extra_columns": {
            "GF & Podium [D]": "235",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "235",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "235,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium inaccessible area; void sides; 900mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium inaccessible area; void sides; 900mm girth",
          "quantity": 201,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 201000,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1257
          },
          "extra_columns": {
            "GF & Podium [D]": "201",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "201",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "201,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To ground floor; round column",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To ground floor; round column",
          "quantity": 30,
          "unit": "m2",
          "rate_aed": 1403,
          "amount_aed": 42090,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1259
          },
          "extra_columns": {
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To ground floor and podium walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To ground floor and podium walls",
          "quantity": 1679,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 2048380,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1261
          },
          "extra_columns": {
            "GF & Podium [D]": "1,679",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,679",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,048,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To gym walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To gym walls",
          "quantity": 49,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 59780,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1263
          },
          "extra_columns": {
            "GF & Podium [D]": "49",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "59,780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower walls",
          "quantity": 3483,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 4249260,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1265
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,636",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1,847",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3,483",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,995,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,253,340.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower pool fascia; 1400mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower pool fascia; 1400mm high",
          "quantity": 132,
          "unit": "m",
          "rate_aed": 1464,
          "amount_aed": 193248,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1267
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "66",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "66",
            "TOTAL QTY [I]": "132",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,624.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "96,624.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 615mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 615mm girth",
          "quantity": 242,
          "unit": "m",
          "rate_aed": 750.3,
          "amount_aed": 181572.59999999998,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1269
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "121",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "121",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "242",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "90,786.30",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "90,786.30",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 615mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 615mm girth - curved",
          "quantity": 116,
          "unit": "m",
          "rate_aed": 825.33,
          "amount_aed": 95738.28,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1271
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "58",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "116",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "47,869.14",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "47,869.14",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 2000mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 2000mm girth",
          "quantity": 66,
          "unit": "m",
          "rate_aed": 2440,
          "amount_aed": 161040,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1273
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "33",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "33",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "80,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/21-P",
          "item_code": "P",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 2000mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-01; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7043 (Tele Grey B, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 2000mm girth - curved",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 2684,
          "amount_aed": 77836,
          "amount_state": "number",
          "printed_page": "2/E/4",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1275
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "40,260.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "37,576.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/22",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 55242074.74,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/22-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-02; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7037 (Dusty Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To ground floor and podium walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-02; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7037 (Dusty Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To ground floor and podium walls",
          "quantity": 1179,
          "unit": "m2",
          "rate_aed": 1200,
          "amount_aed": 1414800,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1303
          },
          "extra_columns": {
            "GF & Podium [D]": "1,179",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,414,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-02; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7037 (Dusty Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-02; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 7037 (Dusty Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower walls",
          "quantity": 16007,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 19528540,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1305
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3,610",
            "Tower 2 [F]": "4,331",
            "Tower 3 [G]": "4,137",
            "Tower 4 [H]": "3,929",
            "TOTAL QTY [I]": "16,007",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,404,200.00",
            "TOWER 2 [P]": "5,283,820.00",
            "TOWER 3 [Q]": "5,047,140.00",
            "TOWER 4 [R]": "4,793,380.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium canopy soffit",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium canopy soffit",
          "quantity": 66,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 80520,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1309
          },
          "extra_columns": {
            "GF & Podium [D]": "66",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To ground floor canopy soffit and inner side walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To ground floor canopy soffit and inner side walls",
          "quantity": 133,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 162260,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1311
          },
          "extra_columns": {
            "GF & Podium [D]": "133",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "133",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "162,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 2340mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 2340mm girth",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 2854.7999999999997,
          "amount_aed": 34257.6,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1313
          },
          "extra_columns": {
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,257.60",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 2340mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 2340mm girth - curved",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 3140.2799999999997,
          "amount_aed": 28262.519999999997,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1315
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,262.52",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 2500mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 2500mm girth",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 250100,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1317
          },
          "extra_columns": {
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "64",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "54,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "195,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3000mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3000mm girth",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 3660,
          "amount_aed": 409920,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1319
          },
          "extra_columns": {
            "GF & Podium [D]": "112",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "409,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3080mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3080mm girth",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 3757.6,
          "amount_aed": 259274.4,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1321
          },
          "extra_columns": {
            "GF & Podium [D]": "69",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "259,274.40",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3000mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3000mm girth - curved",
          "quantity": 6,
          "unit": "m",
          "rate_aed": 4026.0000000000005,
          "amount_aed": 24156.000000000004,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1323
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,156.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3100mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3100mm girth",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 3782,
          "amount_aed": 321470,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1325
          },
          "extra_columns": {
            "GF & Podium [D]": "85",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "321,470.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 4175mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 4175mm girth",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 5093.5,
          "amount_aed": 351451.5,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1327
          },
          "extra_columns": {
            "GF & Podium [D]": "69",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "351,451.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 2415mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 2415mm girth",
          "quantity": 3294,
          "unit": "m",
          "rate_aed": 2244.8,
          "amount_aed": 7394371.2,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1329
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,546",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1,748",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3,294",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,470,460.80",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,923,910.40",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-P",
          "item_code": "P",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 2415mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 2415mm girth - curved",
          "quantity": 1734,
          "unit": "m",
          "rate_aed": 2469.28,
          "amount_aed": 4281731.5200000005,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1331
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "814",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "920",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,734",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,009,993.92",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,271,737.60",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-Q",
          "item_code": "Q",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 2500 girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 2500 girth",
          "quantity": 6770,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 20648500,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1333
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3,513",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3,257",
            "TOTAL QTY [I]": "6,770",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,714,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,933,850.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/22-R",
          "item_code": "R",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium inaccessible area; roof",
          "quantity": 43,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 52460,
          "amount_state": "number",
          "printed_page": "2/E/5",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1335
          },
          "extra_columns": {
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "52,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/23",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 46637835.480000004,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/23-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; roof",
          "quantity": 3566,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 4350520,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1349
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "541",
            "Tower 2 [F]": "1,253",
            "Tower 3 [G]": "611",
            "Tower 4 [H]": "1,161",
            "TOTAL QTY [I]": "3,566",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "660,020.00",
            "TOWER 2 [P]": "1,528,660.00",
            "TOWER 3 [Q]": "745,420.00",
            "TOWER 4 [R]": "1,416,420.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; void sides; 600mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; void sides; 600mm girth",
          "quantity": 2286,
          "unit": "m",
          "rate_aed": 732,
          "amount_aed": 1673352,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1351
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,073",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1,213",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,286",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "785,436.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "887,916.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; void sides; 900mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; void sides; 900mm girth",
          "quantity": 819,
          "unit": "m",
          "rate_aed": 1098,
          "amount_aed": 899262,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1353
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "425",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "394",
            "TOTAL QTY [I]": "819",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "466,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "432,612.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To ground floor and podium walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To ground floor and podium walls",
          "quantity": 278,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 339160,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1355
          },
          "extra_columns": {
            "GF & Podium [D]": "278",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "278",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "339,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-03; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 050 50 10 (Teakwood Brown - Light Brown, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower walls",
          "quantity": 5853,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 7140660,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1357
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2,727",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3,126",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5,853",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,326,940.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,813,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 1725mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 1725mm girth",
          "quantity": 155,
          "unit": "m",
          "rate_aed": 2104.5,
          "amount_aed": 326197.5,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1361
          },
          "extra_columns": {
            "GF & Podium [D]": "155",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "155",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "326,197.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 1725mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 1725mm girth - curved",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 2314.9500000000003,
          "amount_aed": 104172.75000000001,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1363
          },
          "extra_columns": {
            "GF & Podium [D]": "45",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "104,172.75",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 1870mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 1870mm girth",
          "quantity": 114,
          "unit": "m",
          "rate_aed": 2281.4,
          "amount_aed": 260079.6,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1365
          },
          "extra_columns": {
            "GF & Podium [D]": "114",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "260,079.60",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 1870mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 1870mm girth",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 2281.4,
          "amount_aed": 61597.8,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1367
          },
          "extra_columns": {
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "61,597.80",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 1815mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 1815mm girth",
          "quantity": 7829,
          "unit": "m",
          "rate_aed": 1878.8,
          "amount_aed": 14709125.2,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1369
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3,656",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4,173",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7,829",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,868,892.80",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,840,232.40",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 1815mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 1815mm girth - curved",
          "quantity": 1720,
          "unit": "m",
          "rate_aed": 2066.6800000000003,
          "amount_aed": 3554689.6000000006,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1371
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "807",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "913",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,720",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,667,810.76",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,886,878.84",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy coping; 1860mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy coping; 1860mm girth",
          "quantity": 372,
          "unit": "m",
          "rate_aed": 2269.2000000000003,
          "amount_aed": 844142.4000000001,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1373
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "186",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "186",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "372",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "422,071.20",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "422,071.20",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy coping; 1860mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy coping; 1860mm girth - curved",
          "quantity": 66,
          "unit": "m",
          "rate_aed": 2496.1200000000003,
          "amount_aed": 164743.92,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1375
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "33",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "33",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "82,371.96",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "82,371.96",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-P",
          "item_code": "P",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy; roof",
          "quantity": 1164,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 1420080,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1377
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "582",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "582",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "710,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "710,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-Q",
          "item_code": "Q",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium inaccessible area; roof",
          "quantity": 103,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 125660,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1379
          },
          "extra_columns": {
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "125,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-R",
          "item_code": "R",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; roof",
          "quantity": 3801,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 4637220,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1381
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,786",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2,015",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3,801",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,178,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,458,300.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-S",
          "item_code": "S",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; void sides; 600mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; void sides; 600mm girth",
          "quantity": 5358,
          "unit": "m",
          "rate_aed": 732,
          "amount_aed": 3922056,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1383
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2,515",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2,843",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5,358",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,840,980.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,081,076.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-T",
          "item_code": "T",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium soffit bulkhead; 615mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium soffit bulkhead; 615mm girth",
          "quantity": 114,
          "unit": "m",
          "rate_aed": 750.3,
          "amount_aed": 85534.2,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1385
          },
          "extra_columns": {
            "GF & Podium [D]": "114",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "85,534.20",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-U",
          "item_code": "U",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium soffit bulkhead; 615mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium soffit bulkhead; 615mm girth - curved",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 825.33,
          "amount_aed": 22283.91,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1387
          },
          "extra_columns": {
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,283.91",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/23-V",
          "item_code": "V",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 615mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 615mm girth",
          "quantity": 2662,
          "unit": "m",
          "rate_aed": 750.3,
          "amount_aed": 1997298.5999999999,
          "amount_state": "number",
          "printed_page": "2/E/6",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1389
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,269",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1,393",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,662",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "952,130.70",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,045,167.90",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/24",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 53452110.71,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/24-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower soffit bulkhead; 615mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower soffit bulkhead; 615mm girth - curved",
          "quantity": 4119,
          "unit": "m",
          "rate_aed": 825.33,
          "amount_aed": 3399534.27,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1402
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,941",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2,178",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4,119",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,601,965.53",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,797,568.74",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy soffit bulkhead; 730mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy soffit bulkhead; 730mm girth",
          "quantity": 368,
          "unit": "m",
          "rate_aed": 890.6,
          "amount_aed": 327740.8,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1404
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "184",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "184",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "163,870.40",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "163,870.40",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy soffit bulkhead; 730mm girth - curved",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-04; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 000 85 00 (Shadow White - Silver Grey, Matte finish), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy soffit bulkhead; 730mm girth - curved",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 979.6600000000001,
          "amount_aed": 52901.64000000001,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1406
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "27",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "27",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,450.82",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,450.82",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To Tower 2 & 4; ground floor canopy roof and outer side walls",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To Tower 2 & 4; ground floor canopy roof and outer side walls",
          "quantity": 173,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 211060,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1410
          },
          "extra_columns": {
            "GF & Podium [D]": "173",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "173",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "211,060.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 2500mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 2500mm girth",
          "quantity": 445,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 1357250,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1412
          },
          "extra_columns": {
            "GF & Podium [D]": "445",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "445",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,357,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3000mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3000mm girth",
          "quantity": 216,
          "unit": "m",
          "rate_aed": 3660,
          "amount_aed": 790560,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1414
          },
          "extra_columns": {
            "GF & Podium [D]": "216",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "216",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "790,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium coping; 3500mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium coping; 3500mm girth",
          "quantity": 310,
          "unit": "m",
          "rate_aed": 4270,
          "amount_aed": 1323700,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1416
          },
          "extra_columns": {
            "GF & Podium [D]": "310",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "310",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,323,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower coping; 2500mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower coping; 2500mm girth",
          "quantity": 11434,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 34873700,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1418
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5,933",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "5,501",
            "TOTAL QTY [I]": "11,434",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,095,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "16,778,050.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy coping; 2500mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy coping; 2500mm girth",
          "quantity": 454,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 1384700,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1420
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "227",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "227",
            "TOTAL QTY [I]": "454",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "692,350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "692,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy void sides; 900mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy void sides; 900mm girth",
          "quantity": 76,
          "unit": "m",
          "rate_aed": 3050,
          "amount_aed": 231800,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1422
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "38",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "115,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "115,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower canopy roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower canopy roof",
          "quantity": 1012,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 1234640,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1424
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "506",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "506",
            "TOTAL QTY [I]": "1,012",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "617,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "617,320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium inaccessible area; roof",
          "quantity": 142,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 173240,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1426
          },
          "extra_columns": {
            "GF & Podium [D]": "142",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "142",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "173,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; roof",
          "quantity": 2926,
          "unit": "m2",
          "rate_aed": 1220,
          "amount_aed": 3569720,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1428
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1,236",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1,690",
            "TOTAL QTY [I]": "2,926",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,507,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,061,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-P",
          "item_code": "P",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To podium inaccessible area; void sides; 900mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To podium inaccessible area; void sides; 900mm girth",
          "quantity": 107,
          "unit": "m",
          "rate_aed": 1098,
          "amount_aed": 117486,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1430
          },
          "extra_columns": {
            "GF & Podium [D]": "107",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "117,486.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/24-Q",
          "item_code": "Q",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "To tower inaccessible area; void sides; 900mm girth",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Type AL-05; 3mm thick solid core aluminium cladding panels;PVDF coated; colour RAL 9016 (Traffic White, Matte finish, Smooth textured), including secondary support framing system and thermal insulation; water proofing where required; including all fixings, fittings, accessories and all ancillary works as per drawings and specifications — To tower inaccessible area; void sides; 900mm girth",
          "quantity": 4011,
          "unit": "m",
          "rate_aed": 1098,
          "amount_aed": 4404078,
          "amount_state": "number",
          "printed_page": "2/E/7",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1432
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2,081",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1,930",
            "TOTAL QTY [I]": "4,011",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,284,938.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,119,140.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/25",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 5762220,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/25-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Staircase railings; internal purpose made metal balustrade with integrated handrail; comprising polyester powder coated aluminium CHS post, top and bottom rails and handrails; including finishes, fixings, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "BAL-351; 1285mm high; floor mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Staircase railings; internal purpose made metal balustrade with integrated handrail; comprising polyester powder coated aluminium CHS post, top and bottom rails and handrails; including finishes, fixings, supports, accessories and all ancillary works as necessary — BAL-351; 1285mm high; floor mounted",
          "quantity": 867,
          "unit": "m",
          "rate_aed": 870,
          "amount_aed": 754290,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1456
          },
          "extra_columns": {
            "Basement [C]": "70",
            "GF & Podium [D]": "71",
            "Tower 1 [E]": "179",
            "Tower 2 [F]": "194",
            "Tower 3 [G]": "185",
            "Tower 4 [H]": "168",
            "TOTAL QTY [I]": "867",
            "BASEMENTS [M]": "60,900.00",
            "GF & PODIUM [N]": "61,770.00",
            "TOWER 1 [O]": "155,730.00",
            "TOWER 2 [P]": "168,780.00",
            "TOWER 3 [Q]": "160,950.00",
            "TOWER 4 [R]": "146,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Staircase railings; internal purpose made metal balustrade with integrated handrail; comprising polyester powder coated aluminium CHS post, top and bottom rails and handrails; including finishes, fixings, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "BAL-351; 1285mm high; floor mounted; sloping",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Staircase railings; internal purpose made metal balustrade with integrated handrail; comprising polyester powder coated aluminium CHS post, top and bottom rails and handrails; including finishes, fixings, supports, accessories and all ancillary works as necessary — BAL-351; 1285mm high; floor mounted; sloping",
          "quantity": 3344,
          "unit": "m",
          "rate_aed": 870,
          "amount_aed": 2909280,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1458
          },
          "extra_columns": {
            "Basement [C]": "231",
            "GF & Podium [D]": "369",
            "Tower 1 [E]": "596",
            "Tower 2 [F]": "733",
            "Tower 3 [G]": "717",
            "Tower 4 [H]": "698",
            "TOTAL QTY [I]": "3,344",
            "BASEMENTS [M]": "200,970.00",
            "GF & PODIUM [N]": "321,030.00",
            "TOWER 1 [O]": "518,520.00",
            "TOWER 2 [P]": "637,710.00",
            "TOWER 3 [Q]": "623,790.00",
            "TOWER 4 [R]": "607,260.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Staircase railings; internal wall mounted metal handrail; comprising polyester powder coated aluminium CHS handrails and wide flange; including finishes, fixings, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "BAL-725; 965mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Staircase railings; internal wall mounted metal handrail; comprising polyester powder coated aluminium CHS handrails and wide flange; including finishes, fixings, supports, accessories and all ancillary works as necessary — BAL-725; 965mm high; wall mounted",
          "quantity": 516,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 232200,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1462
          },
          "extra_columns": {
            "Basement [C]": "37",
            "GF & Podium [D]": "67",
            "Tower 1 [E]": "96",
            "Tower 2 [F]": "112",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "102",
            "TOTAL QTY [I]": "516",
            "BASEMENTS [M]": "16,650.00",
            "GF & PODIUM [N]": "30,150.00",
            "TOWER 1 [O]": "43,200.00",
            "TOWER 2 [P]": "50,400.00",
            "TOWER 3 [Q]": "45,900.00",
            "TOWER 4 [R]": "45,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Staircase railings; internal wall mounted metal handrail; comprising polyester powder coated aluminium CHS handrails and wide flange; including finishes, fixings, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "BAL-725; 965mm high; wall mounted; sloping",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Staircase railings; internal wall mounted metal handrail; comprising polyester powder coated aluminium CHS handrails and wide flange; including finishes, fixings, supports, accessories and all ancillary works as necessary — BAL-725; 965mm high; wall mounted; sloping",
          "quantity": 3344,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 1504800,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1464
          },
          "extra_columns": {
            "Basement [C]": "231",
            "GF & Podium [D]": "369",
            "Tower 1 [E]": "596",
            "Tower 2 [F]": "733",
            "Tower 3 [G]": "717",
            "Tower 4 [H]": "698",
            "TOTAL QTY [I]": "3,344",
            "BASEMENTS [M]": "103,950.00",
            "GF & PODIUM [N]": "166,050.00",
            "TOWER 1 [O]": "268,200.00",
            "TOWER 2 [P]": "329,850.00",
            "TOWER 3 [Q]": "322,650.00",
            "TOWER 4 [R]": "314,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Metal access ladder with integral safety cage; type AM-411; comprising galvanised steel rung, galvanised steel horizontal flat bar, aluminium guard rail and crown aluminium vertical profile; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1690 x 1700 x 9310 mm high; fixed to aluminium guard rail",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Metal access ladder with integral safety cage; type AM-411; comprising galvanised steel rung, galvanised steel horizontal flat bar, aluminium guard rail and crown aluminium vertical profile; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 1; size 1690 x 1700 x 9310 mm high; fixed to aluminium guard rail",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 8137.500000000001,
          "amount_aed": 97650.00000000001,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,412.50",
            "TOWER 2 [P]": "24,412.50",
            "TOWER 3 [Q]": "24,412.50",
            "TOWER 4 [R]": "24,412.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; 3765mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 3; 3765mm high; wall mounted",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1472
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; 4700mm high; fixed to aluminium guard rail",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 4; 4700mm high; fixed to aluminium guard rail",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 5500,
          "amount_aed": 115500,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1474
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "27,500.00",
            "TOWER 2 [P]": "27,500.00",
            "TOWER 3 [Q]": "33,000.00",
            "TOWER 4 [R]": "27,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; 6250mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 5; 6250mm high; wall mounted",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1476
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "7,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; 10300mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 5; 10300mm high; wall mounted",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10000,
          "amount_aed": 40000,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1478
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0.00",
            "Tower 4 [H]": "0.00",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "40,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; 4300mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 6; 4300mm high; wall mounted",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 5500,
          "amount_aed": 77000,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1480
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "55,000.00",
            "GF & PODIUM [N]": "22,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; 4000mm high; wall mounted",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 7; 4000mm high; wall mounted",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5500,
          "amount_aed": 5500,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1482
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/25-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; 1950mm high; galvanised steel wall rung",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access ladders; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 8; 1950mm high; galvanised steel wall rung",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/E/8",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1484
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "7,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/26",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 486770,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/26-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; 9310mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 2; 9310mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 14440,
          "amount_aed": 57760,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1500
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,440.00",
            "TOWER 2 [P]": "14,440.00",
            "TOWER 3 [Q]": "14,440.00",
            "TOWER 4 [R]": "14,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 960 x 690 x 4300mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 2; size 960 x 690 x 4300mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6670,
          "amount_aed": 6670,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1502
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,670.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 960 x 690 x 10300mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Stainless steel ladders to water tanks; type AM-451; wall mounted stainless steel with safety cage;  including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Type 2; size 960 x 690 x 10300mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1504
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Lift pit ladder; galvanised steel; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 500 x 5850mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Lift pit ladder; galvanised steel; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — Size 500 x 5850mm high",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 120000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1508
          },
          "extra_columns": {
            "Basement [C]": "20",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "120,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Access hatch; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1050 x 900mm; to sewage tank",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Access hatch; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 1050 x 900mm; to sewage tank",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1512
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "5,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Proprietary insulated roof access hatch; comprising fully thermally broken and insulated single-leaf lid, 50mm thick mineral wool insulation, with lifting mechanism compression spring; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RFS-621; size 900 x 900mm",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Proprietary insulated roof access hatch; comprising fully thermally broken and insulated single-leaf lid, 50mm thick mineral wool insulation, with lifting mechanism compression spring; including finishes, fixings, frames, accessories and all ancillary works as necessary — Type RFS-621; size 900 x 900mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1600,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Proprietary insulated roof access hatch; comprising fully thermally broken and insulated single-leaf lid, 50mm thick mineral wool insulation, with lifting mechanism compression spring; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1350 x 3250mm; to galvanised steel ladder at roof",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Proprietary insulated roof access hatch; comprising fully thermally broken and insulated single-leaf lid, 50mm thick mineral wool insulation, with lifting mechanism compression spring; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 1350 x 3250mm; to galvanised steel ladder at roof",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7020,
          "amount_aed": 14040,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,020.00",
            "TOWER 2 [P]": "7,020.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 300mm wide",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 300mm wide",
          "quantity": 267,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 267000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1522
          },
          "extra_columns": {
            "Basement [C]": "93",
            "GF & Podium [D]": "141",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "267",
            "BASEMENTS [M]": "93,000.00",
            "GF & PODIUM [N]": "141,000.00",
            "TOWER 1 [O]": "7,000.00",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "7,000.00",
            "TOWER 4 [R]": "7,000.00",
            "[S]": "TRUE",
            "[V]": "0.09",
            "[W]": "1000"
          }
        },
        {
          "id": "2 - Main/26-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 300 x 300mm; gully trap grating",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 300 x 300mm; gully trap grating",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1524
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[V]": "1000"
          }
        },
        {
          "id": "2 - Main/26-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 450 x 450mm; gully trap grating",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 450 x 450mm; gully trap grating",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 800 x 800mm; sand trap grating",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 800 x 800mm; sand trap grating",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1000 x 100mm; sand trap grating",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 1000 x 100mm; sand trap grating",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1530
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/26-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Press lock stainless steel grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ablution room",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Press lock stainless steel grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — To ablution room",
          "quantity": 5,
          "unit": "m2",
          "rate_aed": 500,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/E/9",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1534
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/27",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "2 - Main",
      "source_collection_aed": 3994290,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/27-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Trench covers; type AM-351;removable metal trench cover to substation trenches; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 6mm thick",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Trench covers; type AM-351;removable metal trench cover to substation trenches; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 6mm thick",
          "quantity": 113,
          "unit": "m2",
          "rate_aed": 1000,
          "amount_aed": 113000,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "113,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Metal guard rail; type BAL-901; polyester powder coated aluminium handrail fixed to balustrade; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "1200mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Metal guard rail; type BAL-901; polyester powder coated aluminium handrail fixed to balustrade; including finishes, fixings, frames, accessories and all ancillary works as necessary — 1200mm high",
          "quantity": 115,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 138000,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1550
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "30",
            "Tower 3 [G]": "18",
            "Tower 4 [H]": "30",
            "TOTAL QTY [I]": "115",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "44,400.00",
            "TOWER 2 [P]": "36,000.00",
            "TOWER 3 [Q]": "21,600.00",
            "TOWER 4 [R]": "36,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Overall size 4390 x 2000 x 4500mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Overall size 4390 x 2000 x 4500mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1554
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,500.00",
            "TOWER 2 [P]": "6,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Overall size 6050 x 2630 x 5800mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Overall size 6050 x 2630 x 5800mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,500.00",
            "TOWER 4 [R]": "6,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Overall size 17690 x 1500 x 4700mm high; to walkway",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Overall size 17690 x 1500 x 4700mm high; to walkway",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 6500,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Overall size 17700 x 1500 x 4700mm high; to walkway",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Overall size 17700 x 1500 x 4700mm high; to walkway",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 6500,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for floor mounted railing; 1150mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Extra over for floor mounted railing; 1150mm high",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 820,
          "amount_aed": 25420,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,100.00",
            "TOWER 2 [P]": "4,100.00",
            "TOWER 3 [Q]": "8,200.00",
            "TOWER 4 [R]": "9,020.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for floor mounted railing; 1150mm high; sloping",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Extra over for floor mounted railing; 1150mm high; sloping",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 820,
          "amount_aed": 29520,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,100.00",
            "TOWER 2 [P]": "4,100.00",
            "TOWER 3 [Q]": "10,660.00",
            "TOWER 4 [R]": "10,660.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for wall mounted railing; 900mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Extra over for wall mounted railing; 900mm high",
          "quantity": 2,
          "unit": "m",
          "rate_aed": 650,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1566
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "650.00",
            "TOWER 4 [R]": "650.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for wall mounted railing; 900mm high; sloping",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Galvanised steel ladder at roof; comprising steel pipe railing, steel tread with chequered plate covering and chequered plate decking with 100mm high skirting, including finishes, fixings, frames, accessories and all ancillary works as necessary — Extra over for wall mounted railing; 900mm high; sloping",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 650,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1568
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,900.00",
            "TOWER 4 [R]": "3,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty proprietary aluminium all metal expansion joint cover; with fire resisting barrier; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Floor to floor; BOH",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Heavy duty proprietary aluminium all metal expansion joint cover; with fire resisting barrier; including finishes, fixings, frames, accessories and all ancillary works as necessary — Floor to floor; BOH",
          "quantity": 1665,
          "unit": "m",
          "rate_aed": 1250,
          "amount_aed": 2081250,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1572
          },
          "extra_columns": {
            "Basement [C]": "420",
            "GF & Podium [D]": "1,245",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,665",
            "BASEMENTS [M]": "525,000.00",
            "GF & PODIUM [N]": "1,556,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Proprietary metal walk system; comprising railings and balustrades; metal grating fixed to support; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type AM-261; catwalks",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Proprietary metal walk system; comprising railings and balustrades; metal grating fixed to support; including finishes, fixings, frames, accessories and all ancillary works as necessary — Type AM-261; catwalks",
          "quantity": 100,
          "unit": "m2",
          "rate_aed": 950,
          "amount_aed": 95000,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1576
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "27",
            "Tower 2 [F]": "29",
            "Tower 3 [G]": "15",
            "Tower 4 [H]": "29",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,650.00",
            "TOWER 2 [P]": "27,550.00",
            "TOWER 3 [Q]": "14,250.00",
            "TOWER 4 [R]": "27,550.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-N",
          "item_code": "N",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Sewage tank ladders; comprising GRP rung, GRP flat barS and proprietary aluminum access hatch; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "6050mm high",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Sewage tank ladders; comprising GRP rung, GRP flat barS and proprietary aluminum access hatch; including finishes, frames, supports, fixings, accessories and all ancillary works as necessary — 6050mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1580
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/27-P",
          "item_code": "P",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Vertical Expansion Joint, wall to wall  including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical Expansion Joint",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — NON-STRUCTURAL METALWORK — Vertical Expansion Joint, wall to wall  including finishes, fixings, frames, accessories and all ancillary works as necessary — Vertical Expansion Joint",
          "quantity": 1169.2,
          "unit": "m2",
          "rate_aed": 1250,
          "amount_aed": 1461500,
          "amount_state": "number",
          "printed_page": "2/E/10",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1584
          },
          "extra_columns": {
            "Basement [C]": "762",
            "GF & Podium [D]": "407",
            "TOTAL QTY [I]": "1,169",
            "BASEMENTS [M]": "952,750.00",
            "GF & PODIUM [N]": "508,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/28",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/28-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Metalwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION E - METALWORK (2/E) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Metalwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/E/11",
          "bill_ref": "2",
          "section_ref": "2/E",
          "source": {
            "sheet": "2 - Main",
            "row": 1593
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/29",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 3223025,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/29-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 1800 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 1; vanity counter; size 1800 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 568,
          "unit": "Nr.",
          "rate_aed": 2512.5,
          "amount_aed": 1427100,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1711
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "134",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "152",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,225.00",
            "TOWER 1 [O]": "336,675.00",
            "TOWER 2 [P]": "326,625.00",
            "TOWER 3 [Q]": "381,900.00",
            "TOWER 4 [R]": "336,675.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; vanity counter; size 900 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 2; vanity counter; size 900 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 1262.5,
          "amount_aed": 464600,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1713
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,100.00",
            "TOWER 1 [O]": "111,100.00",
            "TOWER 2 [P]": "106,050.00",
            "TOWER 3 [Q]": "126,250.00",
            "TOWER 4 [R]": "111,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; vanity counter; size 1050 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 2; vanity counter; size 1050 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 1462.5,
          "amount_aed": 71662.5,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1715
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,387.50",
            "TOWER 1 [O]": "67,275.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; vanity counter; size 1100 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 2; vanity counter; size 1100 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 332,
          "unit": "Nr.",
          "rate_aed": 1537.5,
          "amount_aed": 510450,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,525.00",
            "TOWER 1 [O]": "67,650.00",
            "TOWER 2 [P]": "132,225.00",
            "TOWER 3 [Q]": "153,750.00",
            "TOWER 4 [R]": "135,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 935 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 3; vanity counter; size 935 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 2600,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 1215 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 3; vanity counter; size 1215 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 4; vanity counter; size 2180 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 4; vanity counter; size 2180 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 3050,
          "amount_aed": 146400,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1723
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,100.00",
            "TOWER 1 [O]": "140,300.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 5; vanity counter; size 1790 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 5; vanity counter; size 1790 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 487500,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "115,000.00",
            "TOWER 2 [P]": "112,500.00",
            "TOWER 3 [Q]": "130,000.00",
            "TOWER 4 [R]": "115,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 5; vanity counter; size 1580 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 5; vanity counter; size 1580 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2212.5,
          "amount_aed": 11062.5,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,062.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 7; vanity counter; size 1800 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 7; vanity counter; size 1800 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2512.5,
          "amount_aed": 5025,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,025.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 8; vanity counter; size 1850 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 8; vanity counter; size 1850 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 2587.5,
          "amount_aed": 77625,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,587.50",
            "TOWER 2 [P]": "49,162.50",
            "TOWER 3 [Q]": "2,587.50",
            "TOWER 4 [R]": "23,287.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/29-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 9; vanity counter; size 1875 x 550 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To master's bathroom — Type 9; vanity counter; size 1875 x 550 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/F/1",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/30",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1725175,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/30-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 780 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 780 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 1087.5,
          "amount_aed": 214237.5,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1749
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,700.00",
            "TOWER 1 [O]": "50,025.00",
            "TOWER 2 [P]": "48,937.50",
            "TOWER 3 [Q]": "56,550.00",
            "TOWER 4 [R]": "50,025.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 800 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 800 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 160,
          "unit": "Nr.",
          "rate_aed": 1125,
          "amount_aed": 180000,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "54",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,125.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "59,625.00",
            "TOWER 3 [Q]": "58,500.00",
            "TOWER 4 [R]": "60,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 865 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 865 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1212.5,
          "amount_aed": 9700,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1753
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,425.00",
            "TOWER 2 [P]": "2,425.00",
            "TOWER 3 [Q]": "2,425.00",
            "TOWER 4 [R]": "2,425.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 915 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 915 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1287.5,
          "amount_aed": 12875,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1755
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 950 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 950 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1337.5,
          "amount_aed": 13375,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1757
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,375.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; vanity counter; size 965 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; vanity counter; size 965 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1759
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 2; vanity counter; size 1065 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 2; vanity counter; size 1065 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 1487.5,
          "amount_aed": 551862.5,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1761
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,875.00",
            "TOWER 1 [O]": "130,900.00",
            "TOWER 2 [P]": "126,437.50",
            "TOWER 3 [Q]": "148,750.00",
            "TOWER 4 [R]": "130,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 780 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; vanity counter; size 780 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 1087.5,
          "amount_aed": 212062.5,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1763
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,525.00",
            "TOWER 1 [O]": "50,025.00",
            "TOWER 2 [P]": "48,937.50",
            "TOWER 3 [Q]": "56,550.00",
            "TOWER 4 [R]": "50,025.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 2015 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; vanity counter; size 2015 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 2812.5,
          "amount_aed": 405000,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1765
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,812.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "126,562.50",
            "TOWER 3 [Q]": "146,250.00",
            "TOWER 4 [R]": "129,375.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 1080 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; vanity counter; size 1080 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1512.5,
          "amount_aed": 69575,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1767
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,025.00",
            "TOWER 1 [O]": "66,550.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; vanity counter; size 965 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; vanity counter; size 965 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1769
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 4; vanity counter; size 880 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 4; vanity counter; size 880 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1225,
          "amount_aed": 4900,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1771
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,225.00",
            "TOWER 2 [P]": "1,225.00",
            "TOWER 3 [Q]": "1,225.00",
            "TOWER 4 [R]": "1,225.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 5; vanity counter; size 830 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 5; vanity counter; size 830 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1162.5,
          "amount_aed": 5812.5,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1773
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,812.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/30-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 6; vanity counter; size 915 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To secondary bathroom — Type 6; vanity counter; size 915 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1287.5,
          "amount_aed": 2575,
          "amount_state": "number",
          "printed_page": "2/F/2",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,575.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/31",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 737912.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/31-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; vanity counter; size 800 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 1; vanity counter; size 800 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 925,
          "amount_aed": 42550,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1790
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,850.00",
            "TOWER 1 [O]": "40,700.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; vanity counter; size 890 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 1; vanity counter; size 890 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 341,
          "unit": "Nr.",
          "rate_aed": 1025,
          "amount_aed": 349525,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1792
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,225.00",
            "TOWER 1 [O]": "47,150.00",
            "TOWER 2 [P]": "92,250.00",
            "TOWER 3 [Q]": "106,600.00",
            "TOWER 4 [R]": "94,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; vanity counter; size 980 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 1; vanity counter; size 980 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1137.5,
          "amount_aed": 6825,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1794
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,275.00",
            "TOWER 1 [O]": "1,137.50",
            "TOWER 2 [P]": "1,137.50",
            "TOWER 3 [Q]": "1,137.50",
            "TOWER 4 [R]": "1,137.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; vanity counter; size 1050 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 1; vanity counter; size 1050 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 200,
          "unit": "Nr.",
          "rate_aed": 1212.5,
          "amount_aed": 242500,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1796
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,275.00",
            "TOWER 1 [O]": "55,775.00",
            "TOWER 2 [P]": "60,625.00",
            "TOWER 3 [Q]": "63,050.00",
            "TOWER 4 [R]": "55,775.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 2; vanity counter; size 1400 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 2; vanity counter; size 1400 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1612.5,
          "amount_aed": 41925,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1798
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "29,025.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 3; vanity counter; size 1300 x 550 x 300mm high; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To powder room — Type 3; vanity counter; size 1300 x 550 x 300mm high; with 1Nr. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1800
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,500.00",
            "TOWER 2 [P]": "1,500.00",
            "TOWER 3 [Q]": "1,500.00",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Type FXG-761; size 1810 x 560 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Type FXG-761; size 1810 x 560 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2125,
          "amount_aed": 2125,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1804
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,125.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Type FXG-761; size 1810 x 600 x 300mm high; with 2Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Type FXG-761; size 1810 x 600 x 300mm high; with 2Nrs. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2275,
          "amount_aed": 2275,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1806
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,275.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 2370 x 550 x 450mm high; with 3Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 2370 x 550 x 450mm high; with 3Nrs. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2737.5,
          "amount_aed": 5475,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1808
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,475.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 2385 x 550 x 450mm high; with 3Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 2385 x 550 x 450mm high; with 3Nrs. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2750,
          "amount_aed": 5500,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1810
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 2550 x 550 x 450mm high; with 3Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 2550 x 550 x 450mm high; with 3Nrs. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2950,
          "amount_aed": 2950,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1812
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 2625 x 550 x 450mm high; with 3Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 2625 x 550 x 450mm high; with 3Nrs. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3037.5,
          "amount_aed": 6075,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1814
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,075.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 3000 x 550 x 450mm high; with 3Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 3000 x 550 x 450mm high; with 3Nrs. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3462.5,
          "amount_aed": 3462.5,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1816
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,462.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary",
            "To common areas"
          ],
          "own_description": "Size 4960 x 550 x 450mm high; with 5Nrs. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Vanity counters; including countertop, forming of holes, front/side panels, drawers, hardware, finishes, accessories and all ancillary works as necessary — To common areas — Size 4960 x 550 x 450mm high; with 5Nrs. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5725,
          "amount_aed": 5725,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1818
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,725.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/31-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "TV Joinery Unit including WF-103 Wallpaper on 9mm thk MDF Panel, PT-05 30mm thk Lacquered MDF Panel, PT-105 18mm thk Lacquered MDF Shelf, Shutter, Filler Piece and PT-105 18mm thk Lacquered MDF Skirting and all ancillary works as necessary"
          ],
          "own_description": "To Multipurpose Room",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — TV Joinery Unit including WF-103 Wallpaper on 9mm thk MDF Panel, PT-05 30mm thk Lacquered MDF Panel, PT-105 18mm thk Lacquered MDF Shelf, Shutter, Filler Piece and PT-105 18mm thk Lacquered MDF Skirting and all ancillary works as necessary — To Multipurpose Room",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/F/3",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1822
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/32",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 4045325,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/32-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 1; size 1010 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 1; size 1010 x 210 x 1210mm high",
          "quantity": 568,
          "unit": "Nr.",
          "rate_aed": 1550,
          "amount_aed": 880400,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1836
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "134",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "152",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,900.00",
            "TOWER 1 [O]": "207,700.00",
            "TOWER 2 [P]": "201,500.00",
            "TOWER 3 [Q]": "235,600.00",
            "TOWER 4 [R]": "207,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 2; size 900 x 210 x 1210mm high",
          "quantity": 749,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 1029875,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1838
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "749",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,375.00",
            "TOWER 1 [O]": "244,750.00",
            "TOWER 2 [P]": "233,750.00",
            "TOWER 3 [Q]": "275,000.00",
            "TOWER 4 [R]": "242,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; size 850 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 3; size 850 x 210 x 1210mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 2600,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1840
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 3; size 900 x 210 x 1210mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 6875,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1842
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 4; size 1180 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 4; size 1180 x 210 x 1210mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1800,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1844
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 4; size 1240 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 4; size 1240 x 210 x 1210mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1900,
          "amount_aed": 87400,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1846
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,800.00",
            "TOWER 1 [O]": "83,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 5; size 1200 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 5; size 1200 x 210 x 1210mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 1837.5,
          "amount_aed": 358312.5,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1848
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,025.00",
            "TOWER 1 [O]": "84,525.00",
            "TOWER 2 [P]": "82,687.50",
            "TOWER 3 [Q]": "95,550.00",
            "TOWER 4 [R]": "84,525.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 6; size 1235 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 6; size 1235 x 210 x 1210mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1887.5,
          "amount_aed": 9437.5,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1850
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,437.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 7; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 7; size 900 x 210 x 1210mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 2750,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1852
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 9; size 900 x 210 x 1510mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 9; size 900 x 210 x 1510mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1712.5,
          "amount_aed": 6850,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1854
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,712.50",
            "TOWER 2 [P]": "1,712.50",
            "TOWER 3 [Q]": "1,712.50",
            "TOWER 4 [R]": "1,712.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 850 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 850 x 210 x 1210mm high",
          "quantity": 341,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 443300,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1858
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,700.00",
            "TOWER 1 [O]": "59,800.00",
            "TOWER 2 [P]": "117,000.00",
            "TOWER 3 [Q]": "135,200.00",
            "TOWER 4 [R]": "119,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 880 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 880 x 210 x 1210mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1860
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 900 x 210 x 1210mm high",
          "quantity": 44,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 60500,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1862
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "30",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,750.00",
            "TOWER 2 [P]": "41,250.00",
            "TOWER 3 [Q]": "2,750.00",
            "TOWER 4 [R]": "13,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 2; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 2; size 900 x 210 x 1210mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 510125,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1864
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,750.00",
            "TOWER 1 [O]": "121,000.00",
            "TOWER 2 [P]": "116,875.00",
            "TOWER 3 [Q]": "137,500.00",
            "TOWER 4 [R]": "121,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 850 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; size 850 x 210 x 1210mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 253500,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1866
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,800.00",
            "TOWER 1 [O]": "59,800.00",
            "TOWER 2 [P]": "58,500.00",
            "TOWER 3 [Q]": "67,600.00",
            "TOWER 4 [R]": "59,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 1220 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; size 1220 x 210 x 1210mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 1862.5,
          "amount_aed": 268200,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1868
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,862.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "83,812.50",
            "TOWER 3 [Q]": "96,850.00",
            "TOWER 4 [R]": "85,675.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; size 900 x 210 x 1210mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 63250,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1870
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,750.00",
            "TOWER 1 [O]": "60,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 4 size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 4 size 900 x 210 x 1210mm high",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 27500,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1872
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,375.00",
            "TOWER 2 [P]": "12,375.00",
            "TOWER 3 [Q]": "1,375.00",
            "TOWER 4 [R]": "12,375.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-U",
          "item_code": "U",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 5; size 850 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 5; size 850 x 210 x 1210mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 6500,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1874
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/32-V",
          "item_code": "V",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 6 size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 6 size 900 x 210 x 1210mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 2750,
          "amount_state": "number",
          "printed_page": "2/F/4",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1876
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/33",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1862337.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/33-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 850 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 850 x 210 x 1210mm high",
          "quantity": 341,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 443300,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1890
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,700.00",
            "TOWER 1 [O]": "59,800.00",
            "TOWER 2 [P]": "117,000.00",
            "TOWER 3 [Q]": "135,200.00",
            "TOWER 4 [R]": "119,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 860 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 860 x 210 x 1210mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1312.5,
          "amount_aed": 60375,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1892
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "57,750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 900 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 900 x 210 x 1210mm high",
          "quantity": 202,
          "unit": "Nr.",
          "rate_aed": 1375,
          "amount_aed": 277750,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1894
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "202",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,000.00",
            "TOWER 1 [O]": "63,250.00",
            "TOWER 2 [P]": "68,750.00",
            "TOWER 3 [Q]": "71,500.00",
            "TOWER 4 [R]": "63,250.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 980 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 980 x 210 x 1210mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1896
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,500.00",
            "TOWER 2 [P]": "1,500.00",
            "TOWER 3 [Q]": "1,500.00",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 2; size 1085 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 2; size 1085 x 210 x 1210mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1662.5,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1898
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,300.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "13,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 2; size 1135 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 2; size 1135 x 210 x 1210mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1737.5,
          "amount_aed": 17375,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1900
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,375.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 1300 x 210 x 1300mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets with veneered open shelf; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 1300 x 210 x 1300mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1902
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,000.00",
            "TOWER 2 [P]": "2,000.00",
            "TOWER 3 [Q]": "2,000.00",
            "TOWER 4 [R]": "2,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cabinets; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 8; size 900 x 210 x 1510mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cabinets; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 8; size 900 x 210 x 1510mm high",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 1712.5,
          "amount_aed": 51375,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,712.50",
            "TOWER 2 [P]": "32,537.50",
            "TOWER 3 [Q]": "1,712.50",
            "TOWER 4 [R]": "15,412.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1800 x 140 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 1; size 1800 x 140 x 1210mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 1050,
          "amount_aed": 389550,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "92,400.00",
            "TOWER 2 [P]": "89,250.00",
            "TOWER 3 [Q]": "105,000.00",
            "TOWER 4 [R]": "92,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1800 x 155 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 1; size 1800 x 155 x 1210mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 1050,
          "amount_aed": 206850,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1914
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,400.00",
            "TOWER 1 [O]": "48,300.00",
            "TOWER 2 [P]": "47,250.00",
            "TOWER 3 [Q]": "54,600.00",
            "TOWER 4 [R]": "48,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; size 2015 x 155 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 3; size 2015 x 155 x 1210mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 1137.5,
          "amount_aed": 163800,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1916
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,137.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,187.50",
            "TOWER 3 [Q]": "59,150.00",
            "TOWER 4 [R]": "52,325.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2180 x 140 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 4; size 2180 x 140 x 1210mm high",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 1137.5,
          "amount_aed": 54600,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1918
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,275.00",
            "TOWER 1 [O]": "52,325.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; size 1790 x 155 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 5; size 1790 x 155 x 1210mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 575,
          "amount_aed": 112125,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1920
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,450.00",
            "TOWER 1 [O]": "26,450.00",
            "TOWER 2 [P]": "25,875.00",
            "TOWER 3 [Q]": "29,900.00",
            "TOWER 4 [R]": "26,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; size 1580 x 140 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 6; size 1580 x 140 x 1210mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 212.5,
          "amount_aed": 1062.5,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1922
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,062.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; size 1800 x 210 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 7; size 1800 x 210 x 1210mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1050,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1924
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; size 1850 x 210 x 1510mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 8; size 1850 x 210 x 1510mm high",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 1087.5,
          "amount_aed": 32625,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1926
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,087.50",
            "TOWER 2 [P]": "20,662.50",
            "TOWER 3 [Q]": "1,087.50",
            "TOWER 4 [R]": "9,787.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/33-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; size 1850 x 135 x 1510mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Type 9; size 1850 x 135 x 1510mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1425,
          "amount_aed": 5700,
          "amount_state": "number",
          "printed_page": "2/F/5",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1928
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,425.00",
            "TOWER 2 [P]": "1,425.00",
            "TOWER 3 [Q]": "1,425.00",
            "TOWER 4 [R]": "1,425.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/34",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 3770862.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/34-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 600 x 1190mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 600 x 1190mm high",
          "quantity": 1525,
          "unit": "Nr.",
          "rate_aed": 487.5,
          "amount_aed": 743437.5,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1942
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "360",
            "Tower 2 [F]": "355",
            "Tower 3 [G]": "408",
            "Tower 4 [H]": "360",
            "TOTAL QTY [I]": "1,525",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,475.00",
            "TOWER 1 [O]": "175,500.00",
            "TOWER 2 [P]": "173,062.50",
            "TOWER 3 [Q]": "198,900.00",
            "TOWER 4 [R]": "175,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 600 x 1190mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 600 x 1190mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 487.5,
          "amount_aed": 1950,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1944
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 600 x 1490mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 600 x 1490mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 612.5,
          "amount_aed": 4900,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1946
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,225.00",
            "TOWER 2 [P]": "1,225.00",
            "TOWER 3 [Q]": "1,225.00",
            "TOWER 4 [R]": "1,225.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 700 x 1190mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 700 x 1190mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 575,
          "amount_aed": 5750,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1948
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 1340 x 1190mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 1340 x 1190mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 214500,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1950
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,600.00",
            "TOWER 1 [O]": "50,600.00",
            "TOWER 2 [P]": "49,500.00",
            "TOWER 3 [Q]": "57,200.00",
            "TOWER 4 [R]": "50,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for fixed mirror; size 1350 x 1490mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Open shelves with fixed mirror; including concealed light (measured separately), front/side panels, hardware, finishes, fixings, accessories and all ancillary works as necessary — Extra over for fixed mirror; size 1350 x 1490mm high",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 1387.5,
          "amount_aed": 41625,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1952
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,387.50",
            "TOWER 2 [P]": "26,362.50",
            "TOWER 3 [Q]": "1,387.50",
            "TOWER 4 [R]": "12,487.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 1; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 1; size 200 x 200 x 1200mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 167040,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "52,200.00",
            "TOWER 3 [Q]": "60,320.00",
            "TOWER 4 [R]": "53,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 1; size 240 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 1; size 240 x 200 x 1200mm high",
          "quantity": 568,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 715680,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "134",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "152",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,680.00",
            "TOWER 1 [O]": "168,840.00",
            "TOWER 2 [P]": "163,800.00",
            "TOWER 3 [Q]": "191,520.00",
            "TOWER 4 [R]": "168,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 2; size 200 x 200 x 1200mm high",
          "quantity": 749,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 868840,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "749",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,000.00",
            "TOWER 1 [O]": "206,480.00",
            "TOWER 2 [P]": "197,200.00",
            "TOWER 3 [Q]": "232,000.00",
            "TOWER 4 [R]": "204,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 3; size 200 x 150 x 1200mm high",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 6580,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,580.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 4; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 4; size 200 x 150 x 1200mm high",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 45120,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,880.00",
            "TOWER 1 [O]": "43,240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 5; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 5; size 200 x 150 x 1200mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 183300,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,640.00",
            "TOWER 1 [O]": "43,240.00",
            "TOWER 2 [P]": "42,300.00",
            "TOWER 3 [Q]": "48,880.00",
            "TOWER 4 [R]": "43,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 6; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 6; size 200 x 150 x 1200mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 4700,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 7; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 7; size 200 x 200 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 8; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 8; size 200 x 200 x 1200mm high",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 34800,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,160.00",
            "TOWER 2 [P]": "22,040.00",
            "TOWER 3 [Q]": "1,160.00",
            "TOWER 4 [R]": "10,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 9; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To master's bathroom — Type 9; size 200 x 200 x 1200mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,160.00",
            "TOWER 2 [P]": "1,160.00",
            "TOWER 3 [Q]": "1,160.00",
            "TOWER 4 [R]": "1,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 1; size 200 x 150 x 1200mm high",
          "quantity": 401,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 376940,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "128",
            "Tower 3 [G]": "106",
            "Tower 4 [H]": "110",
            "TOTAL QTY [I]": "401",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,460.00",
            "TOWER 1 [O]": "45,120.00",
            "TOWER 2 [P]": "120,320.00",
            "TOWER 3 [Q]": "99,640.00",
            "TOWER 4 [R]": "103,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/34-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 2; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 2; size 200 x 150 x 1200mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 348740,
          "amount_state": "number",
          "printed_page": "2/F/6",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1982
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,400.00",
            "TOWER 1 [O]": "82,720.00",
            "TOWER 2 [P]": "79,900.00",
            "TOWER 3 [Q]": "94,000.00",
            "TOWER 4 [R]": "82,720.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/35",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 2867356,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/35-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 200 x 150 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 3; size 200 x 150 x 1200mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 183300,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 1998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,640.00",
            "TOWER 1 [O]": "43,240.00",
            "TOWER 2 [P]": "42,300.00",
            "TOWER 3 [Q]": "48,880.00",
            "TOWER 4 [R]": "43,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 3; size 200 x 200 x 1200mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 53360,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "51,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 3; size 200 x 200 x 1200mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 18560,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2002
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,280.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 3; size 200 x 200 x 1200mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2004
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,160.00",
            "TOWER 2 [P]": "1,160.00",
            "TOWER 3 [Q]": "1,160.00",
            "TOWER 4 [R]": "1,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 5; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 5; size 200 x 200 x 1200mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 11600,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2006
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 6; size 200 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shower niche; comprising layers of glass shelving and stone wall finish; including shelves, support, hardware, finishes, accessories, and all ancillary works as necessary — To secondary bathroom — Type 6; size 200 x 200 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 1; size 1800 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 1; size 1800 x 500 x 50mm thick",
          "quantity": 568,
          "unit": "Nr.",
          "rate_aed": 2025,
          "amount_aed": 1150200,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2014
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "134",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "152",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,450.00",
            "TOWER 1 [O]": "271,350.00",
            "TOWER 2 [P]": "263,250.00",
            "TOWER 3 [Q]": "307,800.00",
            "TOWER 4 [R]": "271,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; size 900 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 2; size 900 x 500 x 50mm thick",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 1013,
          "amount_aed": 372784,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2016
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,104.00",
            "TOWER 1 [O]": "89,144.00",
            "TOWER 2 [P]": "85,092.00",
            "TOWER 3 [Q]": "101,300.00",
            "TOWER 4 [R]": "89,144.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; size 1050 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 2; size 1050 x 500 x 50mm thick",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 1181,
          "amount_aed": 57869,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2018
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,543.00",
            "TOWER 1 [O]": "54,326.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 2; size 1100 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 2; size 1100 x 500 x 50mm thick",
          "quantity": 332,
          "unit": "Nr.",
          "rate_aed": 1238,
          "amount_aed": 411016,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2020
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,332.00",
            "TOWER 1 [O]": "54,472.00",
            "TOWER 2 [P]": "106,468.00",
            "TOWER 3 [Q]": "123,800.00",
            "TOWER 4 [R]": "108,944.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; size 900 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 3; size 900 x 500 x 50mm thick",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1013,
          "amount_aed": 5065,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2022
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,065.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 3; size 1050 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 3; size 1050 x 500 x 50mm thick",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1181,
          "amount_aed": 2362,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2024
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,362.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 4; size 2180 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 4; size 2180 x 500 x 50mm thick",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 2453,
          "amount_aed": 117744,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2026
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,906.00",
            "TOWER 1 [O]": "112,838.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 5; size 1790 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 5; size 1790 x 500 x 50mm thick",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 2014,
          "amount_aed": 392730,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2028
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,084.00",
            "TOWER 1 [O]": "92,644.00",
            "TOWER 2 [P]": "90,630.00",
            "TOWER 3 [Q]": "104,728.00",
            "TOWER 4 [R]": "92,644.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 6; size 1580 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 6; size 1580 x 500 x 50mm thick",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1778,
          "amount_aed": 8890,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2030
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,890.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 7; size 1800 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 7; size 1800 x 500 x 50mm thick",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2025,
          "amount_aed": 4050,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2032
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 8; size 1850 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 8; size 1850 x 500 x 50mm thick",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 2081,
          "amount_aed": 62430,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2034
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,081.00",
            "TOWER 2 [P]": "39,539.00",
            "TOWER 3 [Q]": "2,081.00",
            "TOWER 4 [R]": "18,729.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/35-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To master's bathroom"
          ],
          "own_description": "Type 8; size 1875 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To master's bathroom — Type 8; size 1875 x 500 x 50mm thick",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2109,
          "amount_aed": 8436,
          "amount_state": "number",
          "printed_page": "2/F/7",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2036
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,109.00",
            "TOWER 2 [P]": "2,109.00",
            "TOWER 3 [Q]": "2,109.00",
            "TOWER 4 [R]": "2,109.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/36",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 2058002,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/36-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 780 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 780 x 500 x 50mm thick",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 878,
          "amount_aed": 172966,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,024.00",
            "TOWER 1 [O]": "40,388.00",
            "TOWER 2 [P]": "39,510.00",
            "TOWER 3 [Q]": "45,656.00",
            "TOWER 4 [R]": "40,388.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 800 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 800 x 500 x 50mm thick",
          "quantity": 160,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 144000,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "54",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "47,700.00",
            "TOWER 3 [Q]": "46,800.00",
            "TOWER 4 [R]": "48,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 865 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 865 x 500 x 50mm thick",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 973,
          "amount_aed": 7784,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,946.00",
            "TOWER 2 [P]": "1,946.00",
            "TOWER 3 [Q]": "1,946.00",
            "TOWER 4 [R]": "1,946.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 915 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 915 x 500 x 50mm thick",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1029,
          "amount_aed": 10290,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,290.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 950 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 950 x 500 x 50mm thick",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1069,
          "amount_aed": 10690,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,690.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 1; size 965 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 1; size 965 x 500 x 50mm thick",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1086,
          "amount_aed": 17376,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,688.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,688.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 2; size 1065 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 2; size 1065 x 500 x 50mm thick",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 1198,
          "amount_aed": 444458,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,980.00",
            "TOWER 1 [O]": "105,424.00",
            "TOWER 2 [P]": "101,830.00",
            "TOWER 3 [Q]": "119,800.00",
            "TOWER 4 [R]": "105,424.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3 size 780 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3 size 780 x 500 x 50mm thick",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 878,
          "amount_aed": 171210,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,268.00",
            "TOWER 1 [O]": "40,388.00",
            "TOWER 2 [P]": "39,510.00",
            "TOWER 3 [Q]": "45,656.00",
            "TOWER 4 [R]": "40,388.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3 size 2015 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3 size 2015 x 500 x 50mm thick",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 2267,
          "amount_aed": 326448,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,267.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "102,015.00",
            "TOWER 3 [Q]": "117,884.00",
            "TOWER 4 [R]": "104,282.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 3; size 1080 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 3; size 1080 x 500 x 50mm thick",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1215,
          "amount_aed": 55890,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,430.00",
            "TOWER 1 [O]": "53,460.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 4; size 880 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 4; size 880 x 500 x 50mm thick",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 990,
          "amount_aed": 3960,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "990.00",
            "TOWER 2 [P]": "990.00",
            "TOWER 3 [Q]": "990.00",
            "TOWER 4 [R]": "990.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 4; size 965 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 4; size 965 x 500 x 50mm thick",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1086,
          "amount_aed": 17376,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,688.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,688.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 5; size 830 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 5; size 830 x 500 x 50mm thick",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 934,
          "amount_aed": 4670,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,670.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To secondary bathroom"
          ],
          "own_description": "Type 6; size 915 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To secondary bathroom — Type 6; size 915 x 500 x 50mm thick",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1029,
          "amount_aed": 2058,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2083
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,058.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 800 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 800 x 500 x 50mm thick",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 41400,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "39,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 890 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 890 x 500 x 50mm thick",
          "quantity": 341,
          "unit": "Nr.",
          "rate_aed": 1001,
          "amount_aed": 341341,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,009.00",
            "TOWER 1 [O]": "46,046.00",
            "TOWER 2 [P]": "90,090.00",
            "TOWER 3 [Q]": "104,104.00",
            "TOWER 4 [R]": "92,092.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 980 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 980 x 500 x 50mm thick",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1103,
          "amount_aed": 6618,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2091
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,206.00",
            "TOWER 1 [O]": "1,103.00",
            "TOWER 2 [P]": "1,103.00",
            "TOWER 3 [Q]": "1,103.00",
            "TOWER 4 [R]": "1,103.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 1; size 1050 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 1; size 1050 x 500 x 50mm thick",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 1181,
          "amount_aed": 232657,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,086.00",
            "TOWER 1 [O]": "54,326.00",
            "TOWER 2 [P]": "59,050.00",
            "TOWER 3 [Q]": "57,869.00",
            "TOWER 4 [R]": "54,326.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-U",
          "item_code": "U",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 2; size 1400 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 2; size 1400 x 500 x 50mm thick",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 40950,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/36-V",
          "item_code": "V",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary",
            "To powder room"
          ],
          "own_description": "Type 3; size 1300 x 500 x 50mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Veneered shelves; including finishes, fixings, accessories and all ancillary works as necessary — To powder room — Type 3; size 1300 x 500 x 50mm thick",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1465,
          "amount_aed": 5860,
          "amount_state": "number",
          "printed_page": "2/F/8",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2097
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,465.00",
            "TOWER 2 [P]": "1,465.00",
            "TOWER 3 [Q]": "1,465.00",
            "TOWER 4 [R]": "1,465.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/37",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 21341525,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/37-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1735 x 600 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 1735 x 600 x 3165mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8437.5,
          "amount_aed": 33750,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,437.50",
            "TOWER 2 [P]": "8,437.50",
            "TOWER 3 [Q]": "8,437.50",
            "TOWER 4 [R]": "8,437.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1790 x 600 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 1790 x 600 x 3165mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8712.5,
          "amount_aed": 34850,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,712.50",
            "TOWER 2 [P]": "8,712.50",
            "TOWER 3 [Q]": "8,712.50",
            "TOWER 4 [R]": "8,712.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1835 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 1835 x 625 x 3165mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 9300,
          "amount_aed": 148800,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "74,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "74,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1870 x 600 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 1870 x 600 x 3165mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 9100,
          "amount_aed": 18200,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 1970 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 1970 x 625 x 3165mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 9987.5,
          "amount_aed": 49937.5,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,937.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2035 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2035 x 625 x 3165mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 10312.5,
          "amount_aed": 51562.5,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,562.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2120 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2120 x 625 x 3165mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 10750,
          "amount_aed": 3988250,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2127
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "107,500.00",
            "TOWER 1 [O]": "946,000.00",
            "TOWER 2 [P]": "913,750.00",
            "TOWER 3 [Q]": "1,075,000.00",
            "TOWER 4 [R]": "946,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2125 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2125 x 625 x 3165mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10775,
          "amount_aed": 21550,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "21,550.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2135 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2135 x 625 x 3165mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 10825,
          "amount_aed": 2132525,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "86,600.00",
            "TOWER 1 [O]": "497,950.00",
            "TOWER 2 [P]": "487,125.00",
            "TOWER 3 [Q]": "562,900.00",
            "TOWER 4 [R]": "497,950.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2140 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2140 x 625 x 3165mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 10850,
          "amount_aed": 2115750,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2133
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,100.00",
            "TOWER 1 [O]": "499,100.00",
            "TOWER 2 [P]": "488,250.00",
            "TOWER 3 [Q]": "564,200.00",
            "TOWER 4 [R]": "499,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2140 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2140 x 625 x 3165mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 10850,
          "amount_aed": 499100,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,700.00",
            "TOWER 1 [O]": "477,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2150 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2150 x 625 x 3165mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 10900,
          "amount_aed": 1569600,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "490,500.00",
            "TOWER 3 [Q]": "566,800.00",
            "TOWER 4 [R]": "501,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2185 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2185 x 625 x 3165mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 11075,
          "amount_aed": 509450,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,150.00",
            "TOWER 1 [O]": "487,300.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2250 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2250 x 625 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 9375,
          "amount_aed": 18750,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2380 x 600 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2380 x 600 x 3165mm high",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 11587.5,
          "amount_aed": 4264200,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "92,700.00",
            "TOWER 1 [O]": "1,019,700.00",
            "TOWER 2 [P]": "973,350.00",
            "TOWER 3 [Q]": "1,158,750.00",
            "TOWER 4 [R]": "1,019,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2435 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2435 x 625 x 3165mm high",
          "quantity": 332,
          "unit": "Nr.",
          "rate_aed": 12337.5,
          "amount_aed": 4096050,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2145
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "172,725.00",
            "TOWER 1 [O]": "542,850.00",
            "TOWER 2 [P]": "1,061,025.00",
            "TOWER 3 [Q]": "1,233,750.00",
            "TOWER 4 [R]": "1,085,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/37-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2450 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2450 x 625 x 3165mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 12425,
          "amount_aed": 1789200,
          "amount_state": "number",
          "printed_page": "2/F/9",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,425.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "559,125.00",
            "TOWER 3 [Q]": "646,100.00",
            "TOWER 4 [R]": "571,550.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/38",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 15432625,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/38-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; size 2460 x 600 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 1; size 2460 x 600 x 3165mm high",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 11975,
          "amount_aed": 586775,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,925.00",
            "TOWER 1 [O]": "550,850.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2370 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2370 x 625 x 3165mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 12012.5,
          "amount_aed": 60062.5,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "60,062.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2400 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2400 x 625 x 3165mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 12162.5,
          "amount_aed": 121625,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "121,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2585 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2585 x 625 x 3165mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 13100,
          "amount_aed": 209600,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "104,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "104,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2685 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2685 x 625 x 3165mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 13612.5,
          "amount_aed": 626175,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,225.00",
            "TOWER 1 [O]": "598,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2735 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2735 x 625 x 3165mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 13862.5,
          "amount_aed": 55450,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2177
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "13,862.50",
            "TOWER 2 [P]": "13,862.50",
            "TOWER 3 [Q]": "13,862.50",
            "TOWER 4 [R]": "13,862.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; size 2835 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 4; size 2835 x 625 x 3165mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 14375,
          "amount_aed": 57500,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2179
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,375.00",
            "TOWER 2 [P]": "14,375.00",
            "TOWER 3 [Q]": "14,375.00",
            "TOWER 4 [R]": "14,375.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; size 1520 x 625 x 2700mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and 25mm thick wood veneer MDF shutter; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 10; size 1520 x 625 x 2700mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6575,
          "amount_aed": 26300,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,575.00",
            "TOWER 2 [P]": "6,575.00",
            "TOWER 3 [Q]": "6,575.00",
            "TOWER 4 [R]": "6,575.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 1750 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 2; size 1750 x 625 x 2600mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 7287.5,
          "amount_aed": 72875,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "72,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 1755 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 2; size 1755 x 625 x 2600mm high",
          "quantity": 742,
          "unit": "Nr.",
          "rate_aed": 7312.5,
          "amount_aed": 5425875,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "176",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "742",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "146,250.00",
            "TOWER 1 [O]": "1,287,000.00",
            "TOWER 2 [P]": "1,243,125.00",
            "TOWER 3 [Q]": "1,462,500.00",
            "TOWER 4 [R]": "1,287,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 1885 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 2; size 1885 x 625 x 2600mm high",
          "quantity": 288,
          "unit": "Nr.",
          "rate_aed": 7850,
          "amount_aed": 2260800,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "288",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "706,500.00",
            "TOWER 3 [Q]": "816,400.00",
            "TOWER 4 [R]": "722,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 1915 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 2; size 1915 x 625 x 2600mm high",
          "quantity": 390,
          "unit": "Nr.",
          "rate_aed": 7975,
          "amount_aed": 3110250,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "390",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "95,700.00",
            "TOWER 1 [O]": "733,700.00",
            "TOWER 2 [P]": "717,750.00",
            "TOWER 3 [Q]": "829,400.00",
            "TOWER 4 [R]": "733,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; size 2000 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 2; size 2000 x 625 x 2600mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 8325,
          "amount_aed": 1640025,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "66,600.00",
            "TOWER 1 [O]": "382,950.00",
            "TOWER 2 [P]": "374,625.00",
            "TOWER 3 [Q]": "432,900.00",
            "TOWER 4 [R]": "382,950.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; size 1085 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 3; size 1085 x 625 x 2600mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 4512.5,
          "amount_aed": 888962.5,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,100.00",
            "TOWER 1 [O]": "207,575.00",
            "TOWER 2 [P]": "203,062.50",
            "TOWER 3 [Q]": "234,650.00",
            "TOWER 4 [R]": "207,575.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; size (1715+1100) x 625 x 3165mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 5; size (1715+1100) x 625 x 3165mm high; L-shaped",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 14275,
          "amount_aed": 28550,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,550.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/38-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; size (2700+1085) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 7; size (2700+1085) x 625 x 2700mm high; L-shaped",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 16362.5,
          "amount_aed": 261800,
          "amount_state": "number",
          "printed_page": "2/F/10",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "130,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "130,900.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/39",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1554945,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/39-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; size (2700+1100) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 7; size (2700+1100) x 625 x 2700mm high; L-shaped",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 16437.5,
          "amount_aed": 263000,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "131,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "131,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; size (2750+1100) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 7; size (2750+1100) x 625 x 2700mm high; L-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 16650,
          "amount_aed": 166500,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2221
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "166,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; size (2835+1150) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 7; size (2835+1150) x 625 x 2700mm high; L-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 17237.5,
          "amount_aed": 172375,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2223
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "172,375.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; size (1600+1485+1600) x 625 x 2700mm high; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 8; size (1600+1485+1600) x 625 x 2700mm high; U-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 20262.5,
          "amount_aed": 202625,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2225
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "202,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; size (1935+2035) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 9; size (1935+2035) x 625 x 2700mm high; L-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 17162.5,
          "amount_aed": 171625,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2227
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "171,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; size (2365+1335) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 9; size (2365+1335) x 625 x 2700mm high; L-shaped",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 16000,
          "amount_aed": 256000,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2229
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "128,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "128,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 11; size (3210+1800) x 625 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 11; size (3210+1800) x 625 x 2700mm high; L-shaped",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 21662.5,
          "amount_aed": 86650,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2231
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "21,662.50",
            "TOWER 2 [P]": "21,662.50",
            "TOWER 3 [Q]": "21,662.50",
            "TOWER 4 [R]": "21,662.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 12; size 3685 x 625 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 12; size 3685 x 625 x 3100mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 18300,
          "amount_aed": 73200,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2233
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,300.00",
            "TOWER 2 [P]": "18,300.00",
            "TOWER 3 [Q]": "18,300.00",
            "TOWER 4 [R]": "18,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-r2235",
          "item_code": "",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 12; size (2650+2400) x 625 x 3165mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 12; size (2650+2400) x 625 x 3165mm high; L-shaped",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 25077.5,
          "amount_aed": 100310,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,077.50",
            "TOWER 2 [P]": "25,077.50",
            "TOWER 3 [Q]": "25,077.50",
            "TOWER 4 [R]": "25,077.50",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-r2237",
          "item_code": "",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 12; size  1750 x 625 x 3165mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving and glass shutter; including MDF backing, carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light (measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 12; size  1750 x 625 x 3165mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8690,
          "amount_aed": 34760,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2237
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,690.00",
            "TOWER 2 [P]": "8,690.00",
            "TOWER 3 [Q]": "8,690.00",
            "TOWER 4 [R]": "8,690.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/39-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wardrobes; comprising 18mm thick MDF shelving, 25mm thick wood veneer MDF shutter and open shelves; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light(measured separately), hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; size 3350 x 625 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wardrobes; comprising 18mm thick MDF shelving, 25mm thick wood veneer MDF shutter and open shelves; including carcass, frames, supports, front/side/back panels, doors, shelves, drawers, concealed light(measured separately), hardware, finishes, accessories and all ancillary works as necessary — Type 6; size 3350 x 625 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 13950,
          "amount_aed": 27900,
          "amount_state": "number",
          "printed_page": "2/F/11",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/40",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 20338080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/40-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; base unit; size 1770 x 620 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; base unit; size 1770 x 620 x 900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4785,
          "amount_aed": 9570,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,570.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; base unit; size (2025+2360) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; base unit; size (2025+2360) x 630 x 900mm high; L-shaped",
          "quantity": 141,
          "unit": "Nr.",
          "rate_aed": 12030,
          "amount_aed": 1696230,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "541,350.00",
            "TOWER 3 [Q]": "589,470.00",
            "TOWER 4 [R]": "553,380.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; base unit; size 3395 x 640 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; base unit; size 3395 x 640 x 900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 9465,
          "amount_aed": 18930,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; wall unit; size 2540  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; wall unit; size 2540  x 350 x 1100mm high",
          "quantity": 143,
          "unit": "Nr.",
          "rate_aed": 3900,
          "amount_aed": 557700,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "175,500.00",
            "TOWER 3 [Q]": "191,100.00",
            "TOWER 4 [R]": "179,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 1040 x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 1040 x 350 x 1100mm high",
          "quantity": 143,
          "unit": "Nr.",
          "rate_aed": 4350,
          "amount_aed": 622050,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "195,750.00",
            "TOWER 3 [Q]": "213,150.00",
            "TOWER 4 [R]": "200,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; full unit; size 630 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; full unit; size 630 x 615 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3780,
          "amount_aed": 7560,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; full unit; size 1080 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; full unit; size 1080 x 615 x 2600mm high",
          "quantity": 141,
          "unit": "Nr.",
          "rate_aed": 11610,
          "amount_aed": 1637010,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "522,450.00",
            "TOWER 3 [Q]": "568,890.00",
            "TOWER 4 [R]": "534,060.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; stone countertop type ST-101; size 1770 x 620 x 20mm thick; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; stone countertop type ST-101; size 1770 x 620 x 20mm thick; with 1Nr. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2085,
          "amount_aed": 4170,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; stone countertop type ST-101; size (2025+2360) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; stone countertop type ST-101; size (2025+2360) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 5160,
          "amount_aed": 743040,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "232,200.00",
            "TOWER 3 [Q]": "268,320.00",
            "TOWER 4 [R]": "237,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 1; stone countertop type ST-101; size 3395 x 640 x 20mm thick; with 1Nr. opening for gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 1; stone countertop type ST-101; size 3395 x 640 x 20mm thick; with 1Nr. opening for gas hob",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3990,
          "amount_aed": 7980,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; base unit; size (2540+1140) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; base unit; size (2540+1140) x 630 x 900mm high; L-shaped",
          "quantity": 328,
          "unit": "Nr.",
          "rate_aed": 10095,
          "amount_aed": 3311160,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "141,330.00",
            "TOWER 1 [O]": "444,180.00",
            "TOWER 2 [P]": "868,170.00",
            "TOWER 3 [Q]": "969,120.00",
            "TOWER 4 [R]": "888,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; base unit; size (2650+1480) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; base unit; size (2650+1480) x 630 x 900mm high; L-shaped",
          "quantity": 192,
          "unit": "Nr.",
          "rate_aed": 11325,
          "amount_aed": 2174400,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "67,950.00",
            "TOWER 1 [O]": "520,950.00",
            "TOWER 2 [P]": "509,625.00",
            "TOWER 3 [Q]": "554,925.00",
            "TOWER 4 [R]": "520,950.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; wall unit; size (2520+1750)  x 350 x 1100mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; wall unit; size (2520+1750)  x 350 x 1100mm high; L-shaped",
          "quantity": 328,
          "unit": "Nr.",
          "rate_aed": 9375,
          "amount_aed": 3075000,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "131,250.00",
            "TOWER 1 [O]": "412,500.00",
            "TOWER 2 [P]": "806,250.00",
            "TOWER 3 [Q]": "900,000.00",
            "TOWER 4 [R]": "825,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; wall unit; size (2650+1480)  x 350 x 1100mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; wall unit; size (2650+1480)  x 350 x 1100mm high; L-shaped",
          "quantity": 192,
          "unit": "Nr.",
          "rate_aed": 9015,
          "amount_aed": 1730880,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "54,090.00",
            "TOWER 1 [O]": "414,690.00",
            "TOWER 2 [P]": "405,675.00",
            "TOWER 3 [Q]": "441,735.00",
            "TOWER 4 [R]": "414,690.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 330 x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 330 x 350 x 1100mm high",
          "quantity": 1040,
          "unit": "Nr.",
          "rate_aed": 2760,
          "amount_aed": 2870400,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "180",
            "Tower 2 [F]": "262",
            "Tower 3 [G]": "290",
            "Tower 4 [H]": "268",
            "TOTAL QTY [I]": "1,040",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "110,400.00",
            "TOWER 1 [O]": "496,800.00",
            "TOWER 2 [P]": "723,120.00",
            "TOWER 3 [Q]": "800,400.00",
            "TOWER 4 [R]": "739,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/40-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; full unit; size 600 x 615 x 2600mm high",
          "quantity": 520,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 1872000,
          "amount_state": "number",
          "printed_page": "2/F/12",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "131",
            "Tower 3 [G]": "145",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "520",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "72,000.00",
            "TOWER 1 [O]": "324,000.00",
            "TOWER 2 [P]": "471,600.00",
            "TOWER 3 [Q]": "522,000.00",
            "TOWER 4 [R]": "482,400.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/41",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 28454535,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/41-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; stone countertop type ST-101; size (2540+1140) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; stone countertop type ST-101; size (2540+1140) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 332,
          "unit": "Nr.",
          "rate_aed": 4395,
          "amount_aed": 1459140,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "61,530.00",
            "TOWER 1 [O]": "193,380.00",
            "TOWER 2 [P]": "377,970.00",
            "TOWER 3 [Q]": "439,500.00",
            "TOWER 4 [R]": "386,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 2; stone countertop type ST-101; size (2650++1480) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 2; stone countertop type ST-101; size (2650++1480) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 4935,
          "amount_aed": 962325,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,610.00",
            "TOWER 1 [O]": "227,010.00",
            "TOWER 2 [P]": "222,075.00",
            "TOWER 3 [Q]": "256,620.00",
            "TOWER 4 [R]": "227,010.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; base unit; size (2090+1235) x 650 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 3; base unit; size (2090+1235) x 650 x 900mm high; L-shaped",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 9405,
          "amount_aed": 3423420,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "75,240.00",
            "TOWER 1 [O]": "827,640.00",
            "TOWER 2 [P]": "790,020.00",
            "TOWER 3 [Q]": "902,880.00",
            "TOWER 4 [R]": "827,640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; wall unit; size 560 1375  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 3; wall unit; size 560 1375  x 350 x 1100mm high",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 3570,
          "amount_aed": 1299480,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,560.00",
            "TOWER 1 [O]": "314,160.00",
            "TOWER 2 [P]": "299,880.00",
            "TOWER 3 [Q]": "342,720.00",
            "TOWER 4 [R]": "314,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; wall unit; size 1690  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 3; wall unit; size 1690  x 350 x 1100mm high",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 764400,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,800.00",
            "TOWER 1 [O]": "184,800.00",
            "TOWER 2 [P]": "176,400.00",
            "TOWER 3 [Q]": "201,600.00",
            "TOWER 4 [R]": "184,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 880 x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 880 x 350 x 1100mm high",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 3690,
          "amount_aed": 1343160,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,520.00",
            "TOWER 1 [O]": "324,720.00",
            "TOWER 2 [P]": "309,960.00",
            "TOWER 3 [Q]": "354,240.00",
            "TOWER 4 [R]": "324,720.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 3; full unit; size 600 x 615 x 2600mm high",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 1310400,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,800.00",
            "TOWER 1 [O]": "316,800.00",
            "TOWER 2 [P]": "302,400.00",
            "TOWER 3 [Q]": "345,600.00",
            "TOWER 4 [R]": "316,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 3; stone countertop type ST-101; size (2090+1235) x 650 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 3; stone countertop type ST-101; size (2090+1235) x 650 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 4095,
          "amount_aed": 1506960,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,760.00",
            "TOWER 1 [O]": "360,360.00",
            "TOWER 2 [P]": "343,980.00",
            "TOWER 3 [Q]": "409,500.00",
            "TOWER 4 [R]": "360,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; base unit; size (2590+1475) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 4; base unit; size (2590+1475) x 630 x 900mm high; L-shaped",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 11190,
          "amount_aed": 548310,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,570.00",
            "TOWER 1 [O]": "514,740.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; wall unit; size (3190+1140)  x 350 x 1100mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 4; wall unit; size (3190+1140)  x 350 x 1100mm high; L-shaped",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 9765,
          "amount_aed": 478485,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,295.00",
            "TOWER 1 [O]": "449,190.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 590 x 350 x 1070mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 590 x 350 x 1070mm high",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 2685,
          "amount_aed": 131565,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,055.00",
            "TOWER 1 [O]": "123,510.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 4; full unit; size 600 x 615 x 2600mm high",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 176400,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,800.00",
            "TOWER 1 [O]": "165,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 4; stone countertop type ST-101; size (2540+1140) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 4; stone countertop type ST-101; size (2540+1140) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 4875,
          "amount_aed": 238875,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,625.00",
            "TOWER 1 [O]": "224,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; base unit; size 3690 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 5; base unit; size 3690 x 630 x 900mm high",
          "quantity": 369,
          "unit": "Nr.",
          "rate_aed": 10125,
          "amount_aed": 3736125,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "369",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "121,500.00",
            "TOWER 1 [O]": "891,000.00",
            "TOWER 2 [P]": "860,625.00",
            "TOWER 3 [Q]": "972,000.00",
            "TOWER 4 [R]": "891,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; wall unit; size 3660  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 5; wall unit; size 3660  x 350 x 1100mm high",
          "quantity": 736,
          "unit": "Nr.",
          "rate_aed": 6180,
          "amount_aed": 4548480,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "176",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "192",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "736",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "135,960.00",
            "TOWER 1 [O]": "1,087,680.00",
            "TOWER 2 [P]": "1,050,600.00",
            "TOWER 3 [Q]": "1,186,560.00",
            "TOWER 4 [R]": "1,087,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 460 x 350 x 1070mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 460 x 350 x 1070mm high",
          "quantity": 738,
          "unit": "Nr.",
          "rate_aed": 2685,
          "amount_aed": 1981530,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "176",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "192",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "738",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "64,440.00",
            "TOWER 1 [O]": "472,560.00",
            "TOWER 2 [P]": "456,450.00",
            "TOWER 3 [Q]": "515,520.00",
            "TOWER 4 [R]": "472,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 5; full unit; size 600 x 615 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; full unit; size 1050 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 5; full unit; size 1050 x 615 x 2600mm high",
          "quantity": 367,
          "unit": "Nr.",
          "rate_aed": 7830,
          "amount_aed": 2873610,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "367",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "78,300.00",
            "TOWER 1 [O]": "689,040.00",
            "TOWER 2 [P]": "665,550.00",
            "TOWER 3 [Q]": "751,680.00",
            "TOWER 4 [R]": "689,040.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-U",
          "item_code": "U",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 5; stone countertop type ST-101; size 3690 x 630 x 20mm thick; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 5; stone countertop type ST-101; size 3690 x 630 x 20mm thick; with 2Nrs. opening for sink and gas hob",
          "quantity": 373,
          "unit": "Nr.",
          "rate_aed": 4410,
          "amount_aed": 1644930,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "373",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "52,920.00",
            "TOWER 1 [O]": "388,080.00",
            "TOWER 2 [P]": "374,850.00",
            "TOWER 3 [Q]": "441,000.00",
            "TOWER 4 [R]": "388,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-V",
          "item_code": "V",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; base unit; size 1700 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; base unit; size 1700 x 630 x 900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4665,
          "amount_aed": 9330,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2349
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,330.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/41-W",
          "item_code": "W",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; base unit; size 1895 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; base unit; size 1895 x 630 x 900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5205,
          "amount_aed": 10410,
          "amount_state": "number",
          "printed_page": "2/F/13",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2351
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,410.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/42",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 6959340,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/42-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; wall unit; size 1635  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; wall unit; size 1635  x 350 x 1100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4245,
          "amount_aed": 8490,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2361
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,490.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; full unit; size 600 x 615 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2363
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; stone countertop type ST-101; size 1700 x 630 x 20mm thick; with 1Nr. opening for gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; stone countertop type ST-101; size 1700 x 630 x 20mm thick; with 1Nr. opening for gas hob",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2025,
          "amount_aed": 4050,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2365
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 6; stone countertop type ST-101; size 1895 x 630 x 20mm thick; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 6; stone countertop type ST-101; size 1895 x 630 x 20mm thick; with 1Nr. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2265,
          "amount_aed": 4530,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2367
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,530.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; base unit; size (2650+1510) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; base unit; size (2650+1510) x 630 x 900mm high; L-shaped",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 11415,
          "amount_aed": 2214510,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2369
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "91,320.00",
            "TOWER 1 [O]": "525,090.00",
            "TOWER 2 [P]": "513,675.00",
            "TOWER 3 [Q]": "559,335.00",
            "TOWER 4 [R]": "525,090.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; base unit; size (2755+1730) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; base unit; size (2755+1730) x 630 x 900mm high; L-shaped",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 12300,
          "amount_aed": 61500,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2371
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "61,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; wall unit; size 2610 x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; wall unit; size 2610 x 350 x 1100mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 6780,
          "amount_aed": 33900,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2373
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; wall unit; size 2640 x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; wall unit; size 2640 x 350 x 1100mm high",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 4335,
          "amount_aed": 840990,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2375
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,680.00",
            "TOWER 1 [O]": "199,410.00",
            "TOWER 2 [P]": "195,075.00",
            "TOWER 3 [Q]": "212,415.00",
            "TOWER 4 [R]": "199,410.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 485 x 350 x 1070mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 485 x 350 x 1070mm high",
          "quantity": 398,
          "unit": "Nr.",
          "rate_aed": 2025,
          "amount_aed": 805950,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "98",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "398",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "52,650.00",
            "TOWER 1 [O]": "186,300.00",
            "TOWER 2 [P]": "182,250.00",
            "TOWER 3 [Q]": "198,450.00",
            "TOWER 4 [R]": "186,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; full unit; size 600 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; full unit; size 600 x 615 x 2600mm high",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 698400,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,800.00",
            "TOWER 1 [O]": "165,600.00",
            "TOWER 2 [P]": "162,000.00",
            "TOWER 3 [Q]": "176,400.00",
            "TOWER 4 [R]": "165,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; full unit; size 1050 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; full unit; size 1050 x 615 x 2600mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 7830,
          "amount_aed": 39150,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; stone countertop type ST-101; size (2650+1510) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; stone countertop type ST-101; size (2650+1510) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 4965,
          "amount_aed": 978105,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,720.00",
            "TOWER 1 [O]": "228,390.00",
            "TOWER 2 [P]": "223,425.00",
            "TOWER 3 [Q]": "258,180.00",
            "TOWER 4 [R]": "228,390.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 7; stone countertop type ST-101; size (2755+1730) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 7; stone countertop type ST-101; size (2755+1730) x 630 x 20mm thick; L-shaped; with 2Nrs. opening for sink and gas hob",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 5355,
          "amount_aed": 26775,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,775.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; base unit; size 1990 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; base unit; size 1990 x 630 x 900mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 5460,
          "amount_aed": 251160,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,920.00",
            "TOWER 1 [O]": "240,240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; base unit; size 2830 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; base unit; size 2830 x 630 x 900mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 7755,
          "amount_aed": 356730,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,510.00",
            "TOWER 1 [O]": "341,220.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; wall unit; size 1480  x 350 x 1100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; wall unit; size 1480  x 350 x 1100mm high",
          "quantity": 92,
          "unit": "Nr.",
          "rate_aed": 3840,
          "amount_aed": 353280,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,360.00",
            "TOWER 1 [O]": "337,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; full unit; size 630 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; full unit; size 630 x 615 x 2600mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 165600,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,200.00",
            "TOWER 1 [O]": "158,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/42-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; stone countertop type ST-101; size 1990 x 630 x 20mm thick; with 1Nr. opening for gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; stone countertop type ST-101; size 1990 x 630 x 20mm thick; with 1Nr. opening for gas hob",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 2370,
          "amount_aed": 109020,
          "amount_state": "number",
          "printed_page": "2/F/14",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,740.00",
            "TOWER 1 [O]": "104,280.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/43",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1196970,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/43-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 8; stone countertop type ST-101; size 2830 x 630 x 20mm thick; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 8; stone countertop type ST-101; size 2830 x 630 x 20mm thick; with 1Nr. opening for sink",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 3375,
          "amount_aed": 155250,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,750.00",
            "TOWER 1 [O]": "148,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; base unit; size (2440+1835) x 630 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 9; base unit; size (2440+1835) x 630 x 900mm high; L-shaped",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 11730,
          "amount_aed": 58650,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "58,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; wall unit; size  (2440+1835) x 350 x 1100mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 9; wall unit; size  (2440+1835) x 350 x 1100mm high; L-shaped",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 8535,
          "amount_aed": 42675,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "42,675.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 640 x 350 x 1070mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 640 x 350 x 1070mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2685,
          "amount_aed": 13425,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,425.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; full unit; size 1080 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 9; full unit; size 1080 x 615 x 2600mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 11940,
          "amount_aed": 59700,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2419
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "59,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 9; stone countertop type ST-101; size (2440+1835) x 630 x 20mm thick; L-shaped; with 2Nrs. of opening for sink and gas hob",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 9; stone countertop type ST-101; size (2440+1835) x 630 x 20mm thick; L-shaped; with 2Nrs. of opening for sink and gas hob",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 5100,
          "amount_aed": 25500,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "25,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; island unit; size 2000 x 900 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; island unit; size 2000 x 900 x 900mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 9240,
          "amount_aed": 92400,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "92,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; island unit; size 2100 x 900 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; island unit; size 2100 x 900 x 900mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 9690,
          "amount_aed": 155040,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "77,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "77,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; island unit; size 2200 x 950 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; island unit; size 2200 x 950 x 900mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10725,
          "amount_aed": 42900,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,725.00",
            "TOWER 2 [P]": "10,725.00",
            "TOWER 3 [Q]": "10,725.00",
            "TOWER 4 [R]": "10,725.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 11; island unit; size 3200 x 950 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 11; island unit; size 3200 x 950 x 900mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6180,
          "amount_aed": 24720,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2431
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,180.00",
            "TOWER 2 [P]": "6,180.00",
            "TOWER 3 [Q]": "6,180.00",
            "TOWER 4 [R]": "6,180.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; base unit; size 2255 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; base unit; size 2255 x 630 x 900mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 6585,
          "amount_aed": 171210,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "118,530.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "52,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; base unit; size 2400 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; base unit; size 2400 x 630 x 900mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; full unit; size 660 x 615 x 2700mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; full unit; size 660 x 615 x 2700mm high",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 2895,
          "amount_aed": 57900,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,895.00",
            "TOWER 2 [P]": "26,055.00",
            "TOWER 3 [Q]": "2,895.00",
            "TOWER 4 [R]": "26,055.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; wall unit; size 2255  x 350 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; wall unit; size 2255  x 350 x 1210mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 3375,
          "amount_aed": 87750,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "60,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; wall unit; size 2440  x 350 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; wall unit; size 2440  x 350 x 1210mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2535,
          "amount_aed": 10140,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2441
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,535.00",
            "TOWER 2 [P]": "2,535.00",
            "TOWER 3 [Q]": "2,535.00",
            "TOWER 4 [R]": "2,535.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 570 x 350 x 1170mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 570 x 350 x 1170mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 2535,
          "amount_aed": 65910,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2443
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "45,630.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "20,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 640 x 350 x 1170mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 640 x 350 x 1170mm high",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 2535,
          "amount_aed": 76050,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,535.00",
            "TOWER 2 [P]": "48,165.00",
            "TOWER 3 [Q]": "2,535.00",
            "TOWER 4 [R]": "22,815.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-T",
          "item_code": "T",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 890 x 350 x 1170mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 890 x 350 x 1170mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2447
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/43-U",
          "item_code": "U",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; full unit; size 640 x 615 x 2600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; full unit; size 640 x 615 x 2600mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2895,
          "amount_aed": 28950,
          "amount_state": "number",
          "printed_page": "2/F/15",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2449
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/44",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 526808.7224999999,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/44-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; stone countertop type ST-101; size 2000 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; stone countertop type ST-101; size 2000 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 7830,
          "amount_aed": 78300,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2460
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "78,300.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; stone countertop type ST-101; size 2100 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; stone countertop type ST-101; size 2100 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 8100,
          "amount_aed": 129600,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2462
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "64,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "64,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; stone countertop type ST-101; size 2200 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; stone countertop type ST-101; size 2200 x 900 x 20mm thick; including side panels; with 1Nr. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8370,
          "amount_aed": 33480,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2464
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,370.00",
            "TOWER 2 [P]": "8,370.00",
            "TOWER 3 [Q]": "8,370.00",
            "TOWER 4 [R]": "8,370.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; stone countertop type ST-101; size 2255 x 630 x 20mm thick; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; stone countertop type ST-101; size 2255 x 630 x 20mm thick; with 1Nr. opening for sink",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 2700,
          "amount_aed": 70200,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2466
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "48,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 10; stone countertop type ST-101; size 2440 x 630 x 20mm thick; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 10; stone countertop type ST-101; size 2440 x 630 x 20mm thick; with 1Nr. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2910,
          "amount_aed": 11640,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,910.00",
            "TOWER 2 [P]": "2,910.00",
            "TOWER 3 [Q]": "2,910.00",
            "TOWER 4 [R]": "2,910.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 11; stone countertop type ST-101; size 3200 x 900 x 20mm thick;  including side panels; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to show kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 11; stone countertop type ST-101; size 3200 x 900 x 20mm thick;  including side panels; with 1Nr. opening for sink",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2470
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; base unit; size (1530+2145+2490) x 630 x 900mm high; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; base unit; size (1530+2145+2490) x 630 x 900mm high; U-shaped",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 16772.6041875,
          "amount_aed": 67090.41675,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2474
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,772.60",
            "TOWER 2 [P]": "16,772.60",
            "TOWER 3 [Q]": "16,772.60",
            "TOWER 4 [R]": "16,772.60",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; wall unit; size 2360  x 615 350 x 825mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; wall unit; size 2360  x 615 350 x 825mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2564.5764375,
          "amount_aed": 10258.30575,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2476
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,564.58",
            "TOWER 2 [P]": "2,564.58",
            "TOWER 3 [Q]": "2,564.58",
            "TOWER 4 [R]": "2,564.58",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; wall unit; size 3285  x 615 350 x 825mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; wall unit; size 3285  x 615 350 x 825mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4545,
          "amount_aed": 18180,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2478
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,545.00",
            "TOWER 2 [P]": "4,545.00",
            "TOWER 3 [Q]": "4,545.00",
            "TOWER 4 [R]": "4,545.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; wall unit; size 2360  x 615 350 x 825mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; wall unit; size 2360  x 615 350 x 825mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1245,
          "amount_aed": 4980,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2480
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,245.00",
            "TOWER 2 [P]": "1,245.00",
            "TOWER 3 [Q]": "1,245.00",
            "TOWER 4 [R]": "1,245.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; wall unit; size 3285  x 615 350 x 825mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; wall unit; size 3285  x 615 350 x 825mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4575,
          "amount_aed": 18300,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2482
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,575.00",
            "TOWER 2 [P]": "4,575.00",
            "TOWER 3 [Q]": "4,575.00",
            "TOWER 4 [R]": "4,575.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 460 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 460 x 350 x 1180mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2070,
          "amount_aed": 8280,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2484
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,070.00",
            "TOWER 2 [P]": "2,070.00",
            "TOWER 3 [Q]": "2,070.00",
            "TOWER 4 [R]": "2,070.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 475 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 475 x 350 x 1180mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2130,
          "amount_aed": 8520,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2486
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,130.00",
            "TOWER 2 [P]": "2,130.00",
            "TOWER 3 [Q]": "2,130.00",
            "TOWER 4 [R]": "2,130.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 780 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 780 x 350 x 1180mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3510,
          "amount_aed": 14040,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2488
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,510.00",
            "TOWER 2 [P]": "3,510.00",
            "TOWER 3 [Q]": "3,510.00",
            "TOWER 4 [R]": "3,510.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 900 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 900 x 350 x 1180mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4035,
          "amount_aed": 16140,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2490
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,035.00",
            "TOWER 2 [P]": "4,035.00",
            "TOWER 3 [Q]": "4,035.00",
            "TOWER 4 [R]": "4,035.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-R",
          "item_code": "R",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; stone countertop type ST-101; size 925 x 630x 20mm thick; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; stone countertop type ST-101; size 925 x 630x 20mm thick; U-shaped",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1110,
          "amount_aed": 4440,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2492
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,110.00",
            "TOWER 2 [P]": "1,110.00",
            "TOWER 3 [Q]": "1,110.00",
            "TOWER 4 [R]": "1,110.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/44-S",
          "item_code": "S",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 13; stone countertop type ST-101; size (1530+2145+2490) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to dirty kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 13; stone countertop type ST-101; size (1530+2145+2490) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5340,
          "amount_aed": 21360,
          "amount_state": "number",
          "printed_page": "2/F/16",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2494
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,340.00",
            "TOWER 2 [P]": "5,340.00",
            "TOWER 3 [Q]": "5,340.00",
            "TOWER 4 [R]": "5,340.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/45",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1348175.205,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/45-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; base unit; size (1700+1185+2280) x 630 x 900mm high; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; base unit; size (1700+1185+2280) x 630 x 900mm high; U-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 15168.029625,
          "amount_aed": 151680.29624999998,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2506
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "151,680.30",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; base unit; size (1700+1190+2290) x 630 x 900mm high; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; base unit; size (1700+1190+2290) x 630 x 900mm high; U-shaped",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 15168.029625,
          "amount_aed": 242688.474,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2508
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "121,344.24",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "121,344.24",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; base unit; size 575 x 630 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; base unit; size 575 x 630 x 900mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 2934.8628750000003,
          "amount_aed": 76306.43475,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2510
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "52,827.53",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "23,478.90",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; wall unit; size 1325  x 615 x 825mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; wall unit; size 1325  x 615 x 825mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 4545,
          "amount_aed": 118170,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2512
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "81,810.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "36,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; wall unit; size 2435  x 350 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; wall unit; size 2435  x 350 x 1210mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1245,
          "amount_aed": 32370,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2514
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "22,410.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,960.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; wall unit; size 3485  x 350 x 1210mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; wall unit; size 3485  x 350 x 1210mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 2730,
          "amount_aed": 70980,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "49,140.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 865 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 865 x 350 x 1180mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 3900,
          "amount_aed": 101400,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "70,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 900 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 900 x 350 x 1180mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 4080,
          "amount_aed": 106080,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "73,440.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "32,640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 1000 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 1000 x 350 x 1180mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 4485,
          "amount_aed": 116610,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "80,730.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,880.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for glass unit; size 1085 x 350 x 1180mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Extra over for glass unit; size 1085 x 350 x 1180mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 4890,
          "amount_aed": 127140,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "88,020.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "39,120.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; stone countertop type ST-101; size (1700+1185+2280) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; stone countertop type ST-101; size (1700+1185+2280) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 6600,
          "amount_aed": 66000,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "66,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; stone countertop type ST-101; size (1700+1190+2290) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; stone countertop type ST-101; size (1700+1190+2290) x 900 x 20mm thick; with 1Nr. opening for sink; U-shaped",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6600,
          "amount_aed": 105600,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "52,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "52,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/45-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 14; stone countertop type ST-101; size 575 x 630 x 20mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kitchen cabinets; to back kitchen; including countertop, forming of holes, frames, carcass, supports, front/back/side panels, doors, shelves, drawers, concealed light (measured separately), skirting, hardware, finishes, accessories and all ancillary works as necessary — Type 14; stone countertop type ST-101; size 575 x 630 x 20mm thick",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1275,
          "amount_aed": 33150,
          "amount_state": "number",
          "printed_page": "2/F/17",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "22,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,200.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/46",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 59190,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/46-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (2100+660) x 600 x 900mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (2100+660) x 600 x 900mm high; L-shaped",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7215,
          "amount_aed": 7215,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2552
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,215.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; size (2100+660) x 20mm thick; 100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; size (2100+660) x 20mm thick; 100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 525,
          "amount_aed": 525,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2554
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "525.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; size (2100+660) x 30mm thick polished granite; L-shaped; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; size (2100+660) x 30mm thick polished granite; L-shaped; with 1Nr. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3135,
          "amount_aed": 3135,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,135.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2180 x 600 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2180 x 600 x 900mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5700,
          "amount_aed": 5700,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; size 2180 x 20mm thick; 100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; size 2180 x 20mm thick; 100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; size 2180 x 30mm thick polished granite; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; size 2180 x 30mm thick polished granite; with 1Nr. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2475,
          "amount_aed": 2475,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,475.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2310 x 600 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2310 x 600 x 900mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6030,
          "amount_aed": 6030,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; size 2380 x 20mm thick; 100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; size 2380 x 20mm thick; 100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 390,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2566
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "390.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; size 2310 x 30mm thick polished granite; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; size 2310 x 30mm thick polished granite; with 1Nr. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2568
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2760 x 600 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2760 x 600 x 900mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7215,
          "amount_aed": 7215,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2570
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,215.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; size 2760 x 20mm thick; 100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; size 2760 x 20mm thick; 100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2572
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; size 2760 x 30mm thick polished granite; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; size 2760 x 30mm thick polished granite; with 1Nr. opening for sink",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3135,
          "amount_aed": 3135,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2574
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,135.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2580 x 600 x 900mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2580 x 600 x 900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6690,
          "amount_aed": 13380,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2576
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; size 2580 x 20mm thick; 100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; size 2580 x 20mm thick; 100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2578
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/46-Q",
          "item_code": "Q",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; size 2580 x 30mm thick polished granite; with 1Nr. opening for sink",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Base units; type FXG-681; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; size 2580 x 30mm thick polished granite; with 1Nr. opening for sink",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2910,
          "amount_aed": 5820,
          "amount_state": "number",
          "printed_page": "2/F/18",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2580
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/47",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 217100,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/47-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3695 x 630 x 3000mm high; base cabinet",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 3695 x 630 x 3000mm high; base cabinet",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10050,
          "amount_aed": 20100,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2600
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; type ST-01; size 2835 x 600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; type ST-01; size 2835 x 600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1270,
          "amount_aed": 2540,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2602
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; type ST-01; size 2835 x 630mm wide",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; type ST-01; size 2835 x 630mm wide",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2240,
          "amount_aed": 4480,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2604
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2600 x 700 x 900mm high; base cabinet",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2600 x 700 x 900mm high; base cabinet",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5730,
          "amount_aed": 5730,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2606
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,730.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; type ST-01; size 2600 x 810mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; type ST-01; size 2600 x 810mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1580,
          "amount_aed": 1580,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2608
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,580.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; type ST-01; size 2600 x 600mm wide",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; type ST-01; size 2600 x 600mm wide",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1970,
          "amount_aed": 1970,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2610
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2600 x 700 x 1290mm high; wall shelves",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Pantry cabinet; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2600 x 700 x 1290mm high; wall shelves",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6460,
          "amount_aed": 6460,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2612
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Bench and shelves; including padded cushion, carcass, frames, supports, front/side/back panels, shelves, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 4350 x 400 x 450mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Bench and shelves; including padded cushion, carcass, frames, supports, front/side/back panels, shelves, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 4350 x 400 x 450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5480,
          "amount_aed": 5480,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2616
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Gym cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1680 x 900 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Gym cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 1680 x 900 x 3000mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15880,
          "amount_aed": 15880,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2620
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3950 x 625 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 3950 x 625 x 3000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 74060,
          "amount_aed": 148120,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2624
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "148,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for backsplash; type ST-01; size 1360 x 770mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for backsplash; type ST-01; size 1360 x 770mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1310,
          "amount_aed": 2620,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2626
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/47-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; type ST-01; size 1360 x 625mm wide",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Kids pantry & seating niche; including counter top, cushion backrest, seating, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; type ST-01; size 1360 x 625mm wide",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1070,
          "amount_aed": 2140,
          "amount_state": "number",
          "printed_page": "2/F/19",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2628
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,140.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/48",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 351001.2,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/48-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2500 x 500 x 2700mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2500 x 500 x 2700mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 11810,
          "amount_aed": 23620,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for mirror; type GL-01; size 840 x 1300mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for mirror; type GL-01; size 840 x 1300mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 600.6,
          "amount_aed": 1201.2,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2643
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,201.20",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for countertop; type WD-102; size 840 x 500mm wide",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for countertop; type WD-102; size 840 x 500mm wide",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 950,
          "amount_aed": 1900,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2645
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2050 x 430 x 2700mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2050 x 430 x 2700mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 8330,
          "amount_aed": 16660,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2647
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "16,660.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (2000+1800) x 400/150 x 2700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (2000+1800) x 400/150 x 2700mm high; L-shaped",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10110,
          "amount_aed": 20220,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2649
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (1650+950) x 300 x 100mm 1700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (1650+950) x 300 x 100mm 1700mm high; L-shaped",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6190,
          "amount_aed": 6190,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2651
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,190.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (2280+1230) x 300 x 100mm 1700mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Lockers; including counter top, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (2280+1230) x 300 x 100mm 1700mm high; L-shaped",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8350,
          "amount_aed": 8350,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2653
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Main lobby display shelving; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (3520+3175) x 450 x 4600mm high; L-shaped",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Main lobby display shelving; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (3520+3175) x 450 x 4600mm high; L-shaped",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 48510,
          "amount_aed": 97020,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2657
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "97,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Main lobby display shelving; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3150 x 450 x 4600mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Main lobby display shelving; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 3150 x 450 x 4600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 22820,
          "amount_aed": 45640,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2659
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 7620 x 730 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 7620 x 730 x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 55180,
          "amount_aed": 110360,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "110,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for storage shutter; type GL-01; size 640 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for storage shutter; type GL-01; size 640 x 3100mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 790,
          "amount_aed": 3160,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2665
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for mirror wall; type GL-01; size 1490 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for mirror wall; type GL-01; size 1490 x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3460,
          "amount_aed": 6920,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for mirror wall; type GL-01; size 1530 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for mirror wall; type GL-01; size 1530 x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3560,
          "amount_aed": 7120,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2669
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/48-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for mirror shelf back panel; type GL-01; size 500 x 1754mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Mirror wall with TV niche & cabinet; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Extra over for mirror shelf back panel; type GL-01; size 500 x 1754mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 660,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/F/20",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2671
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/49",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1457360,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/49-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "TV and artwork niche wall; with fixed shelves; including stone wall, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 8635 x 150 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — TV and artwork niche wall; with fixed shelves; including stone wall, carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 8635 x 150 x 3000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 13600,
          "amount_aed": 27200,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "TV niche wall and cabinets; with fixed shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 4275 x 540 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — TV niche wall and cabinets; with fixed shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 4275 x 540 x 3000mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 24240,
          "amount_aed": 24240,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "TV niche wall and cabinets; with fixed shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 7060 x 540 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — TV niche wall and cabinets; with fixed shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 7060 x 540 x 3000mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 40030,
          "amount_aed": 40030,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2690
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Passage entry portal; including frames, supports, side panels, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3422 x 1100 x 4550mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Passage entry portal; including frames, supports, side panels, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 3422 x 1100 x 4550mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5510,
          "amount_aed": 11020,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2694
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Reception counter; including counter top, carcass, frames, supports, front/side/back panels, shelves, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2400 x 800 x 1050mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Reception counter; including counter top, carcass, frames, supports, front/side/back panels, shelves, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2400 x 800 x 1050mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 40000,
          "amount_aed": 160000,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2698
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "160,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shoe racks; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (1460+1180) x 300 x 1050mm high; L-shaped; to ablution room",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shoe racks; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (1460+1180) x 300 x 1050mm high; L-shaped; to ablution room",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2910,
          "amount_aed": 2910,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Shoe racks; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size (2810+980) x 300 x 1050mm high; L-shaped; to ablution room",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Shoe racks; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size (2810+980) x 300 x 1050mm high; L-shaped; to ablution room",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4180,
          "amount_aed": 4180,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2704
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall storage; with open shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 835 x 550 x 2400mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall storage; with open shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 835 x 550 x 2400mm high",
          "quantity": 332,
          "unit": "Nr.",
          "rate_aed": 3530,
          "amount_aed": 1171960,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2708
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,420.00",
            "TOWER 1 [O]": "155,320.00",
            "TOWER 2 [P]": "303,580.00",
            "TOWER 3 [Q]": "353,000.00",
            "TOWER 4 [R]": "310,640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/49-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall storage; with open shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1450 x 550 x 3100mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall storage; with open shelves; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 1450 x 550 x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7910,
          "amount_aed": 15820,
          "amount_state": "number",
          "printed_page": "2/F/21",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2710
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/50",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 1526080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/50-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall units; type FXG-601; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2580 x 400 x 750mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall units; type FXG-601; including carcass, frames, supports, front/side/back panels, shelves, doors, hardware, finishes, skirting, accessories and all ancillary works as necessary — Size 2580 x 400 x 750mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2710,
          "amount_aed": 5420,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1810 x 300 x 25mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 1810 x 300 x 25mm thick",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1090,
          "amount_aed": 1090,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2050 x 300 x 25mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 2050 x 300 x 25mm thick",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1230,
          "amount_aed": 1230,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,230.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2500 x 300 x 25mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 2500 x 300 x 25mm thick",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2800 x 300 x 25mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 2800 x 300 x 25mm thick",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1680,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2810 x 300 x 25mm thick",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall mounted desktop MDF board; with white laminate and PVC edge; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 2810 x 300 x 25mm thick",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1690,
          "amount_aed": 1690,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2739
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,690.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Wall panel; in MDF; with 5mm groove; including brackets, hardware, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 4380 x 110 x 3000mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Wall panel; in MDF; with 5mm groove; including brackets, hardware, finishes, accessories and all ancillary works as necessary — Size 4380 x 110 x 3000mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26280,
          "amount_aed": 26280,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2743
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 850 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 850 x 210 x 1200mm high",
          "quantity": 888,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 532800,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2747
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "140",
            "Tower 2 [F]": "230",
            "Tower 3 [G]": "262",
            "Tower 4 [H]": "230",
            "TOTAL QTY [I]": "888",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,600.00",
            "TOWER 1 [O]": "84,000.00",
            "TOWER 2 [P]": "138,000.00",
            "TOWER 3 [Q]": "157,200.00",
            "TOWER 4 [R]": "138,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 860 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 860 x 210 x 1200mm high",
          "quantity": 56,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 33600,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2749
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "26,400.00",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 900 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 900 x 210 x 1200mm high",
          "quantity": 1478,
          "unit": "Nr.",
          "rate_aed": 620,
          "amount_aed": 916360,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "54",
            "Tower 1 [E]": "359",
            "Tower 2 [F]": "362",
            "Tower 3 [G]": "356",
            "Tower 4 [H]": "347",
            "TOTAL QTY [I]": "1,478",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,480.00",
            "TOWER 1 [O]": "222,580.00",
            "TOWER 2 [P]": "224,440.00",
            "TOWER 3 [Q]": "220,720.00",
            "TOWER 4 [R]": "215,140.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 915 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 915 x 200 x 1200mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 610,
          "amount_aed": 610,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2753
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 930 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 930 x 210 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 640,
          "amount_aed": 1280,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2755
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 950 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 950 x 200 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 630,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2757
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/50-P",
          "item_code": "P",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 950 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 950 x 210 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 640,
          "amount_aed": 1280,
          "amount_state": "number",
          "printed_page": "2/F/22",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2759
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "640.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/51",
      "section": "COMPOSITE ITEMS",
      "sheet": "2 - Main",
      "source_collection_aed": 762430,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/51-A",
          "item_code": "A",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 975 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 975 x 210 x 1200mm high",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 660,
          "amount_aed": 5940,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-B",
          "item_code": "B",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1000 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1000 x 200 x 1200mm high",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 650,
          "amount_aed": 7150,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-C",
          "item_code": "C",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1050 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1050 x 200 x 1200mm high",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 690,
          "amount_aed": 12420,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "690.00",
            "TOWER 2 [P]": "5,520.00",
            "TOWER 3 [Q]": "690.00",
            "TOWER 4 [R]": "5,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-D",
          "item_code": "D",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1070 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1070 x 210 x 1200mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 710,
          "amount_aed": 263410,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,100.00",
            "TOWER 1 [O]": "62,480.00",
            "TOWER 2 [P]": "60,350.00",
            "TOWER 3 [Q]": "71,000.00",
            "TOWER 4 [R]": "62,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-E",
          "item_code": "E",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1100 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1100 x 210 x 1200mm high",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 730,
          "amount_aed": 8760,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,300.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-F",
          "item_code": "F",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1120 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1120 x 210 x 1200mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 740,
          "amount_aed": 145780,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,920.00",
            "TOWER 1 [O]": "34,040.00",
            "TOWER 2 [P]": "33,300.00",
            "TOWER 3 [Q]": "38,480.00",
            "TOWER 4 [R]": "34,040.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-G",
          "item_code": "G",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1180 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1180 x 210 x 1200mm high",
          "quantity": 387,
          "unit": "Nr.",
          "rate_aed": 770,
          "amount_aed": 297990,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "387",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "70,840.00",
            "TOWER 2 [P]": "69,300.00",
            "TOWER 3 [Q]": "80,080.00",
            "TOWER 4 [R]": "70,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-H",
          "item_code": "H",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1185 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1185 x 210 x 1200mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 770,
          "amount_aed": 770,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "770.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-J",
          "item_code": "J",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1240 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1240 x 210 x 1200mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 810,
          "amount_aed": 4050,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-K",
          "item_code": "K",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1260 x 210 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1260 x 210 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 810,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "810.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "810.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-L",
          "item_code": "L",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1350 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1350 x 200 x 1200mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 870,
          "amount_aed": 870,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "870.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-M",
          "item_code": "M",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1870 x 200 x 1200mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Cistern enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1870 x 200 x 1200mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1160,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/51-N",
          "item_code": "N",
          "section": "COMPOSITE ITEMS",
          "heading_path": [
            "Bathtub enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1730 x 850 x 500mm high",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — COMPOSITE ITEMS — Bathtub enclosure; including stone ledge, vertical cover, hangers, ironmongery, frames, supports, accessories and all ancillary works as necessary — Size 1730 x 850 x 500mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2270,
          "amount_aed": 11350,
          "amount_state": "number",
          "printed_page": "2/F/23",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/52",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/52-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Woodwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION F - WOOD WORK (2/F) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Woodwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/F/24",
          "bill_ref": "2",
          "section_ref": "2/F",
          "source": {
            "sheet": "2 - Main",
            "row": 2831
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/53",
      "section": "COVERS AND LININGS",
      "sheet": "2 - Main",
      "source_collection_aed": 16074270.66,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/53-A",
          "item_code": "A",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Substructure Waterproofing",
            "Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Waterproofing system B; to horizontal surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Substructure Waterproofing — Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary — Waterproofing system B; to horizontal surfaces",
          "quantity": 44306,
          "unit": "m2",
          "rate_aed": 110,
          "amount_aed": 4873660,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2950
          },
          "extra_columns": {
            "Basement [C]": "29,087",
            "GF & Podium [D]": "15,219",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44,306",
            "BASEMENTS [M]": "3,199,570.00",
            "GF & PODIUM [N]": "1,674,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-B",
          "item_code": "B",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Substructure Waterproofing",
            "Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Waterproofing system B; to vertical surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Substructure Waterproofing — Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary — Waterproofing system B; to vertical surfaces",
          "quantity": 19043,
          "unit": "m2",
          "rate_aed": 110,
          "amount_aed": 2094730,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2952
          },
          "extra_columns": {
            "Basement [C]": "19,043",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19,043",
            "BASEMENTS [M]": "2,094,730.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-C",
          "item_code": "C",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Substructure Waterproofing",
            "Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Waterproofing to sprayed concrete of shoring walls",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Substructure Waterproofing — Waterproofing system; single layer PVC membrane; including surface preparation, adhesive, protection, accessories and all ancillary works as necessary — Waterproofing to sprayed concrete of shoring walls",
          "quantity": 7333,
          "unit": "m2",
          "rate_aed": 110,
          "amount_aed": 806630,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2954
          },
          "extra_columns": {
            "Basement [C]": "7,333",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7,333",
            "BASEMENTS [M]": "806,630.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-D",
          "item_code": "D",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Wet Area Waterproofing",
            "Polymer modified cementitious waterproofing; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-411; to horizontal surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Wet Area Waterproofing — Polymer modified cementitious waterproofing; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary — Type WPS-411; to horizontal surfaces",
          "quantity": 852,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 38340,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2960
          },
          "extra_columns": {
            "Basement [C]": "24",
            "GF & Podium [D]": "59",
            "Tower 1 [E]": "192",
            "Tower 2 [F]": "204",
            "Tower 3 [G]": "183",
            "Tower 4 [H]": "190",
            "TOTAL QTY [I]": "852",
            "BASEMENTS [M]": "1,080.00",
            "GF & PODIUM [N]": "2,655.00",
            "TOWER 1 [O]": "8,640.00",
            "TOWER 2 [P]": "9,180.00",
            "TOWER 3 [Q]": "8,235.00",
            "TOWER 4 [R]": "8,550.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-E",
          "item_code": "E",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Wet Area Waterproofing",
            "Polymer modified cementitious waterproofing; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-411; to horizontal; to units balcony",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Wet Area Waterproofing — Polymer modified cementitious waterproofing; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary — Type WPS-411; to horizontal; to units balcony",
          "quantity": 32749,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 1473705,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,108",
            "Tower 1 [E]": "7,153",
            "Tower 2 [F]": "8,457",
            "Tower 3 [G]": "8,058",
            "Tower 4 [H]": "7,973",
            "TOTAL QTY [I]": "32,749",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,860.00",
            "TOWER 1 [O]": "321,885.00",
            "TOWER 2 [P]": "380,565.00",
            "TOWER 3 [Q]": "362,610.00",
            "TOWER 4 [R]": "358,785.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-F",
          "item_code": "F",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "GRP waterproof lining system; to concrete water tank; 4mm thick (min.); comprising multiple layers of resin, glass fibers and finishing coat; including surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-211; to horizontal surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — GRP waterproof lining system; to concrete water tank; 4mm thick (min.); comprising multiple layers of resin, glass fibers and finishing coat; including surface preparation, protection, accessories and all ancillary works as necessary — Type WPS-211; to horizontal surfaces",
          "quantity": 1680,
          "unit": "m2",
          "rate_aed": 188,
          "amount_aed": 315840,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2966
          },
          "extra_columns": {
            "Basement [C]": "1,580",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,680",
            "BASEMENTS [M]": "297,040.00",
            "GF & PODIUM [N]": "18,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-G",
          "item_code": "G",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "GRP waterproof lining system; to concrete water tank; 4mm thick (min.); comprising multiple layers of resin, glass fibers and finishing coat; including surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-211; to vertical surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — GRP waterproof lining system; to concrete water tank; 4mm thick (min.); comprising multiple layers of resin, glass fibers and finishing coat; including surface preparation, protection, accessories and all ancillary works as necessary — Type WPS-211; to vertical surfaces",
          "quantity": 1760,
          "unit": "m2",
          "rate_aed": 188,
          "amount_aed": 330880,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2968
          },
          "extra_columns": {
            "Basement [C]": "1,581",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,760",
            "BASEMENTS [M]": "297,228.00",
            "GF & PODIUM [N]": "33,652.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-H",
          "item_code": "H",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Liquid applied waterproofing system; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-201; to horizontal surface; to wet areas",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Liquid applied waterproofing system; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary — Type WPS-201; to horizontal surface; to wet areas",
          "quantity": 38288.57,
          "unit": "m2",
          "rate_aed": 53,
          "amount_aed": 2029294.21,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,980",
            "Tower 1 [E]": "8,425",
            "Tower 2 [F]": "9,330",
            "Tower 3 [G]": "9,657",
            "Tower 4 [H]": "8,897",
            "TOTAL QTY [I]": "38,289",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "104,940.00",
            "TOWER 1 [O]": "446,525.00",
            "TOWER 2 [P]": "494,490.00",
            "TOWER 3 [Q]": "511,798.21",
            "TOWER 4 [R]": "471,541.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/53-J",
          "item_code": "J",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Liquid applied waterproofing system; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WPS-201; to vertical surface; to wet areas",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Liquid applied waterproofing system; including surface preparation, turning-up, protection, accessories and all ancillary works as necessary — Type WPS-201; to vertical surface; to wet areas",
          "quantity": 77569.65,
          "unit": "m2",
          "rate_aed": 53,
          "amount_aed": 4111191.4499999997,
          "amount_state": "number",
          "printed_page": "2/G/1",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3,284",
            "Tower 1 [E]": "17,242",
            "Tower 2 [F]": "19,224",
            "Tower 3 [G]": "19,614",
            "Tower 4 [H]": "18,206",
            "TOTAL QTY [I]": "77,570",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "174,052.00",
            "TOWER 1 [O]": "913,826.00",
            "TOWER 2 [P]": "1,018,872.00",
            "TOWER 3 [Q]": "1,039,523.45",
            "TOWER 4 [R]": "964,918.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/54",
      "section": "DAMP-PROOF COURSES",
      "sheet": "2 - Main",
      "source_collection_aed": 4575633,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/54-A",
          "item_code": "A",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Roof Areas Waterproofing",
            "Inverted warm roof with bituminous waterproof membrane; monolithic fully bonded membrane 'inverted' roof covering system; comprising 100mm thick extruded polystyrene boards and geotextile membrane; including turn-ups, surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RFS-131; to horizontal surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Roof Areas Waterproofing — Inverted warm roof with bituminous waterproof membrane; monolithic fully bonded membrane 'inverted' roof covering system; comprising 100mm thick extruded polystyrene boards and geotextile membrane; including turn-ups, surface preparation, protection, accessories and all ancillary works as necessary — Type RFS-131; to horizontal surfaces",
          "quantity": 4063,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 812600,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 2998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "526",
            "Tower 1 [E]": "888",
            "Tower 2 [F]": "890",
            "Tower 3 [G]": "872",
            "Tower 4 [H]": "887",
            "TOTAL QTY [I]": "4,063",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "105,200.00",
            "TOWER 1 [O]": "177,600.00",
            "TOWER 2 [P]": "178,000.00",
            "TOWER 3 [Q]": "174,400.00",
            "TOWER 4 [R]": "177,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-B",
          "item_code": "B",
          "section": "COVERS AND LININGS",
          "heading_path": [
            "Roof Areas Waterproofing",
            "Inverted warm roof with bituminous waterproof membrane; monolithic fully bonded membrane 'inverted' roof covering system; comprising 100mm thick extruded polystyrene boards and geotextile membrane; including turn-ups, surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RFS-131; to vertical surfaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — COVERS AND LININGS — Roof Areas Waterproofing — Inverted warm roof with bituminous waterproof membrane; monolithic fully bonded membrane 'inverted' roof covering system; comprising 100mm thick extruded polystyrene boards and geotextile membrane; including turn-ups, surface preparation, protection, accessories and all ancillary works as necessary — Type RFS-131; to vertical surfaces",
          "quantity": 472,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 94400,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "174",
            "Tower 1 [E]": "74",
            "Tower 2 [F]": "75",
            "Tower 3 [G]": "74",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "472",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,800.00",
            "TOWER 1 [O]": "14,800.00",
            "TOWER 2 [P]": "15,000.00",
            "TOWER 3 [Q]": "14,800.00",
            "TOWER 4 [R]": "15,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-C",
          "item_code": "C",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Polythene sheet; moisture proofing membrane 0.3mm; including surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "1200 gauge; below slab on grade",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Polythene sheet; moisture proofing membrane 0.3mm; including surface preparation, protection, accessories and all ancillary works as necessary — 1200 gauge; below slab on grade",
          "quantity": 480,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 4320,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3006
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "480",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "480",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-D",
          "item_code": "D",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Polythene sheet; moisture proofing membrane 0.3mm; including surface preparation, protection, accessories and all ancillary works as necessary"
          ],
          "own_description": "1200 gauge; below raft slab",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Polythene sheet; moisture proofing membrane 0.3mm; including surface preparation, protection, accessories and all ancillary works as necessary — 1200 gauge; below raft slab",
          "quantity": 25917,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 233253,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3008
          },
          "extra_columns": {
            "Basement [C]": "25,917",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25,917",
            "BASEMENTS [M]": "233,253.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-E",
          "item_code": "E",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Acoustic barrier; including accessories and all ancillary works as necessary"
          ],
          "own_description": "To service floors",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Acoustic barrier; including accessories and all ancillary works as necessary — To service floors",
          "quantity": 1828,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 36560,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3012
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "435",
            "Tower 2 [F]": "466",
            "Tower 3 [G]": "461",
            "Tower 4 [H]": "466",
            "TOTAL QTY [I]": "1,828",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,700.00",
            "TOWER 2 [P]": "9,320.00",
            "TOWER 3 [Q]": "9,220.00",
            "TOWER 4 [R]": "9,320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-F",
          "item_code": "F",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Absorpsive acoustic celing"
          ],
          "own_description": "Class A",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Absorpsive acoustic celing — Class A",
          "quantity": 353,
          "unit": "m2",
          "rate_aed": 250,
          "amount_aed": 88250,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3016
          },
          "extra_columns": {
            "GF & Podium [D]": "353",
            "TOTAL QTY [I]": "353",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "88,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-G",
          "item_code": "G",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Absorpsive acoustic celing"
          ],
          "own_description": "Class B (NRC/αw 0.85)",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Absorpsive acoustic celing — Class B (NRC/αw 0.85)",
          "quantity": 419,
          "unit": "m2",
          "rate_aed": 250,
          "amount_aed": 104750,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3018
          },
          "extra_columns": {
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "126",
            "Tower 3 [G]": "127",
            "Tower 4 [H]": "68",
            "TOTAL QTY [I]": "419",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,500.00",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "31,750.00",
            "TOWER 4 [R]": "17,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/54-H",
          "item_code": "H",
          "section": "DAMP-PROOF COURSES",
          "heading_path": [
            "Absorpsive acoustic celing"
          ],
          "own_description": "Class C (NRC/αw 0.70)",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — DAMP-PROOF COURSES — Absorpsive acoustic celing — Class C (NRC/αw 0.70)",
          "quantity": 12806,
          "unit": "m2",
          "rate_aed": 250,
          "amount_aed": 3201500,
          "amount_state": "number",
          "printed_page": "2/G/2",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3020
          },
          "extra_columns": {
            "Basement [C]": "185",
            "GF & Podium [D]": "1,161",
            "Tower 1 [E]": "2,632",
            "Tower 2 [F]": "3,145",
            "Tower 3 [G]": "2,855",
            "Tower 4 [H]": "2,828",
            "TOTAL QTY [I]": "12,806",
            "BASEMENTS [M]": "46,250.00",
            "GF & PODIUM [N]": "290,250.00",
            "TOWER 1 [O]": "658,000.00",
            "TOWER 2 [P]": "786,250.00",
            "TOWER 3 [Q]": "713,750.00",
            "TOWER 4 [R]": "707,000.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/55",
      "section": "INSULATION",
      "sheet": "2 - Main",
      "source_collection_aed": 14121191.93,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/55-A",
          "item_code": "A",
          "section": "INSULATION",
          "heading_path": [
            "Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type INS-101; 70mm thick",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary — Type INS-101; 70mm thick",
          "quantity": null,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3047
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-B",
          "item_code": "B",
          "section": "INSULATION",
          "heading_path": [
            "Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type INS-101; 70mm thick",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary — Type INS-101; 70mm thick",
          "quantity": 7959,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 636720,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3049
          },
          "extra_columns": {
            "Basement [C]": "3,835",
            "GF & Podium [D]": "4,124",
            "TOTAL QTY [I]": "7,959",
            "BASEMENTS [M]": "306,800.00",
            "GF & PODIUM [N]": "329,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-C",
          "item_code": "C",
          "section": "INSULATION",
          "heading_path": [
            "Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type INS-101; 70mm thick; to A/C and non A/C spaces",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Aluminium foil faced thermal insulation; including accessories and all ancillary works as necessary — Type INS-101; 70mm thick; to A/C and non A/C spaces",
          "quantity": 3069,
          "unit": "",
          "rate_aed": 80,
          "amount_aed": 245520,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3,069",
            "Tower 1 [E]": "0",
            "TOTAL QTY [I]": "3,069",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "245,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-D",
          "item_code": "D",
          "section": "INSULATION",
          "heading_path": [
            "Acoustic resilient mat; including accessories and all ancillary works as necessary"
          ],
          "own_description": "To common areas",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Acoustic resilient mat; including accessories and all ancillary works as necessary — To common areas",
          "quantity": 27234,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 2178720,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3055
          },
          "extra_columns": {
            "Basement [C]": "420",
            "GF & Podium [D]": "3,246",
            "Tower 1 [E]": "5,385",
            "Tower 2 [F]": "6,265",
            "Tower 3 [G]": "6,085",
            "Tower 4 [H]": "5,833",
            "TOTAL QTY [I]": "27,234",
            "BASEMENTS [M]": "33,600.00",
            "GF & PODIUM [N]": "259,680.00",
            "TOWER 1 [O]": "430,800.00",
            "TOWER 2 [P]": "501,200.00",
            "TOWER 3 [Q]": "486,800.00",
            "TOWER 4 [R]": "466,640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-E",
          "item_code": "E",
          "section": "INSULATION",
          "heading_path": [
            "Acoustic resilient mat; including accessories and all ancillary works as necessary"
          ],
          "own_description": "To mechanical areas",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Acoustic resilient mat; including accessories and all ancillary works as necessary — To mechanical areas",
          "quantity": 4664.6,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 373168,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3057
          },
          "extra_columns": {
            "Basement [C]": "489",
            "GF & Podium [D]": "2,387",
            "Tower 1 [E]": "418",
            "Tower 2 [F]": "612",
            "Tower 3 [G]": "329",
            "Tower 4 [H]": "431",
            "TOTAL QTY [I]": "4,665",
            "BASEMENTS [M]": "39,080.00",
            "GF & PODIUM [N]": "190,968.00",
            "TOWER 1 [O]": "33,440.00",
            "TOWER 2 [P]": "48,920.00",
            "TOWER 3 [Q]": "26,280.00",
            "TOWER 4 [R]": "34,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-F",
          "item_code": "F",
          "section": "INSULATION",
          "heading_path": [
            "Polyurethane acoustic floor mat; including edge insulation strip, accessories and all ancillary works as necessary"
          ],
          "own_description": "To units; 6mm thick",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Polyurethane acoustic floor mat; including edge insulation strip, accessories and all ancillary works as necessary — To units; 6mm thick",
          "quantity": 120079.37,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 9606349.6,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3,826",
            "Tower 1 [E]": "26,489",
            "Tower 2 [F]": "31,012",
            "Tower 3 [G]": "30,001",
            "Tower 4 [H]": "28,751",
            "TOTAL QTY [I]": "120,079",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "306,080.00",
            "TOWER 1 [O]": "2,119,120.00",
            "TOWER 2 [P]": "2,480,960.00",
            "TOWER 3 [Q]": "2,400,109.60",
            "TOWER 4 [R]": "2,300,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/55-G",
          "item_code": "G",
          "section": "INSULATION",
          "heading_path": [
            "Polyethylene film; including accessories and all ancillary works as necessary"
          ],
          "own_description": "To units; 0.2mm thick",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — INSULATION — Polyethylene film; including accessories and all ancillary works as necessary — To units; 0.2mm thick",
          "quantity": 120079.37,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 1080714.33,
          "amount_state": "number",
          "printed_page": "2/G/3",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3,826",
            "Tower 1 [E]": "26,489",
            "Tower 2 [F]": "31,012",
            "Tower 3 [G]": "30,001",
            "Tower 4 [H]": "28,751",
            "TOTAL QTY [I]": "120,079",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,434.00",
            "TOWER 1 [O]": "238,401.00",
            "TOWER 2 [P]": "279,108.00",
            "TOWER 3 [Q]": "270,012.33",
            "TOWER 4 [R]": "258,759.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/56",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/56-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Thermal and Moisture Protection in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION G - THERMAL AND MOISTURE PROTECTION (2/G) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Thermal and Moisture Protection in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/G/4",
          "bill_ref": "2",
          "section_ref": "2/G",
          "source": {
            "sheet": "2 - Main",
            "row": 3099
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/57",
      "section": "DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 34807871,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/57-A",
          "item_code": "A",
          "section": "DOORS",
          "heading_path": [
            "Internal Doors",
            "Wood doors; laminate panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-01; size 900 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Internal Doors — Wood doors; laminate panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-01; size 900 x 2200mm; single leaf",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2530,
          "amount_aed": 10120,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-B",
          "item_code": "B",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D01; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D01; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 1372,
          "unit": "Nr.",
          "rate_aed": 5451,
          "amount_aed": 7478772,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "53",
            "Tower 1 [E]": "316",
            "Tower 2 [F]": "333",
            "Tower 3 [G]": "339",
            "Tower 4 [H]": "331",
            "TOTAL QTY [I]": "1,372",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "288,903.00",
            "TOWER 1 [O]": "1,722,516.00",
            "TOWER 2 [P]": "1,815,183.00",
            "TOWER 3 [Q]": "1,847,889.00",
            "TOWER 4 [R]": "1,804,281.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-C",
          "item_code": "C",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D02; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D02; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 369,
          "unit": "Nr.",
          "rate_aed": 5451,
          "amount_aed": 2011419,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "89",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "369",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,608.00",
            "TOWER 1 [O]": "479,688.00",
            "TOWER 2 [P]": "485,139.00",
            "TOWER 3 [Q]": "523,296.00",
            "TOWER 4 [R]": "479,688.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-D",
          "item_code": "D",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D03; size 1100 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D03; size 1100 x 2200mm; single leaf",
          "quantity": 3020,
          "unit": "Nr.",
          "rate_aed": 4001.9999999999995,
          "amount_aed": 12086039.999999998,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "95",
            "Tower 1 [E]": "678",
            "Tower 2 [F]": "785",
            "Tower 3 [G]": "733",
            "Tower 4 [H]": "729",
            "TOTAL QTY [I]": "3,020",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "380,190.00",
            "TOWER 1 [O]": "2,713,356.00",
            "TOWER 2 [P]": "3,141,570.00",
            "TOWER 3 [Q]": "2,933,466.00",
            "TOWER 4 [R]": "2,917,458.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-E",
          "item_code": "E",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D04; size 1100 x 2200mm; single leaf; with glass panel size 1100 x 400mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D04; size 1100 x 2200mm; single leaf; with glass panel size 1100 x 400mm high",
          "quantity": 226,
          "unit": "Nr.",
          "rate_aed": 3530,
          "amount_aed": 797780,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "70",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "56",
            "TOTAL QTY [I]": "226",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,650.00",
            "TOWER 1 [O]": "158,850.00",
            "TOWER 2 [P]": "247,100.00",
            "TOWER 3 [Q]": "176,500.00",
            "TOWER 4 [R]": "197,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-F",
          "item_code": "F",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D05; size 1000 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D05; size 1000 x 2200mm; single leaf",
          "quantity": 3296,
          "unit": "Nr.",
          "rate_aed": 3450,
          "amount_aed": 11371200,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "105",
            "Tower 1 [E]": "683",
            "Tower 2 [F]": "855",
            "Tower 3 [G]": "832",
            "Tower 4 [H]": "821",
            "TOTAL QTY [I]": "3,296",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "362,250.00",
            "TOWER 1 [O]": "2,356,350.00",
            "TOWER 2 [P]": "2,949,750.00",
            "TOWER 3 [Q]": "2,870,400.00",
            "TOWER 4 [R]": "2,832,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-G",
          "item_code": "G",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D06; size 1000 x 2200mm; bi-foldable door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D06; size 1000 x 2200mm; bi-foldable door",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 3300,
          "amount_aed": 739200,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,500.00",
            "TOWER 1 [O]": "148,500.00",
            "TOWER 2 [P]": "227,700.00",
            "TOWER 3 [Q]": "165,000.00",
            "TOWER 4 [R]": "181,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-H",
          "item_code": "H",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D10; size 1600 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D10; size 1600 x 2200mm; double leaf; 60mins FR",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 6300,
          "amount_aed": 201600,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "119,700.00",
            "TOWER 3 [Q]": "12,600.00",
            "TOWER 4 [R]": "56,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-J",
          "item_code": "J",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D11; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D11; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7200,
          "amount_aed": 28800,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,200.00",
            "TOWER 2 [P]": "7,200.00",
            "TOWER 3 [Q]": "7,200.00",
            "TOWER 4 [R]": "7,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-K",
          "item_code": "K",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D12; size 110 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D12; size 110 x 2200mm; single leaf",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 3480,
          "amount_aed": 48720,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,480.00",
            "TOWER 2 [P]": "38,280.00",
            "TOWER 3 [Q]": "3,480.00",
            "TOWER 4 [R]": "3,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-L",
          "item_code": "L",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-02; size 900 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-02; size 900 x 2200mm; single leaf",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2380,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-M",
          "item_code": "M",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-03; size 1000 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-03; size 1000 x 2200mm; single leaf",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2640,
          "amount_aed": 10560,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/57-N",
          "item_code": "N",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-04; size 1150 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-04; size 1150 x 2200mm; single leaf",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 3040,
          "amount_aed": 21280,
          "amount_state": "number",
          "printed_page": "2/H/1",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/58",
      "section": "DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 6467176,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/58-A",
          "item_code": "A",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-04; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-04; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3240,
          "amount_aed": 6480,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3260
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-B",
          "item_code": "B",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-04; size 1150 x 2200mm; single leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-04; size 1150 x 2200mm; single leaf; 90mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5200,
          "amount_aed": 5200,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3262
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-C",
          "item_code": "C",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DT-05; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; solid core; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DT-05; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 5200,
          "amount_aed": 62400,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3264
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "62,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-D",
          "item_code": "D",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D08; size 850 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D08; size 850 x 2200mm; double leaf",
          "quantity": 1766,
          "unit": "Nr.",
          "rate_aed": 2646,
          "amount_aed": 4672836,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3268
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "63",
            "Tower 1 [E]": "449",
            "Tower 2 [F]": "411",
            "Tower 3 [G]": "435",
            "Tower 4 [H]": "408",
            "TOTAL QTY [I]": "1,766",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "166,698.00",
            "TOWER 1 [O]": "1,188,054.00",
            "TOWER 2 [P]": "1,087,506.00",
            "TOWER 3 [Q]": "1,151,010.00",
            "TOWER 4 [R]": "1,079,568.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-E",
          "item_code": "E",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D09; size 1250 x 2200mm; double leaf; bi-folding door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D09; size 1250 x 2200mm; double leaf; bi-folding door",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3650,
          "amount_aed": 7300,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3270
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,650.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-F",
          "item_code": "F",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D13; size 1200 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; MDF shutter panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D13; size 1200 x 2200mm; double leaf",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 34000,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3272
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "34,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-G",
          "item_code": "G",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D24; size 900 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D24; size 900 x 2200mm; single leaf",
          "quantity": 429,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 1544400,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3276
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "429",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "90,000.00",
            "TOWER 1 [O]": "327,600.00",
            "TOWER 2 [P]": "396,000.00",
            "TOWER 3 [Q]": "370,800.00",
            "TOWER 4 [R]": "360,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-H",
          "item_code": "H",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D27; size 900 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D27; size 900 x 2200mm; single leaf",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-J",
          "item_code": "J",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D33; size 1150 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D33; size 1150 x 2200mm; single leaf",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 4240,
          "amount_aed": 25440,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3280
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-K",
          "item_code": "K",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D34; size 850 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D34; size 850 x 2200mm; single leaf",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 2690,
          "amount_aed": 40350,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3282
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-L",
          "item_code": "L",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D36; size 110 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D36; size 110 x 2200mm; single leaf",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 16400,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-M",
          "item_code": "M",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D37; size 900 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D37; size 900 x 2200mm; double leaf",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2950,
          "amount_aed": 5900,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3286
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-N",
          "item_code": "N",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D40; size 900 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D40; size 900 x 2200mm; double leaf",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 2990,
          "amount_aed": 8970,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-P",
          "item_code": "P",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D41; size 870 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 45mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D41; size 870 x 2200mm; single leaf",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 3500,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-Q",
          "item_code": "Q",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 50mm thick wooden sliding door; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D31; size 1800 x 3000mm; double sliding",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 50mm thick wooden sliding door; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D31; size 1800 x 3000mm; double sliding",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7730,
          "amount_aed": 7730,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3294
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,730.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/58-R",
          "item_code": "R",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 50mm thick wooden sliding door; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D38; size 1300 x 2350mm; single sliding",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 50mm thick wooden sliding door; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D38; size 1300 x 2350mm; single sliding",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4670,
          "amount_aed": 4670,
          "amount_state": "number",
          "printed_page": "2/H/2",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/59",
      "section": "DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 9467420,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/59-A",
          "item_code": "A",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D21; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D21; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 439,
          "unit": "Nr.",
          "rate_aed": 7950,
          "amount_aed": 3490050,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3307
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "107",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "97",
            "TOTAL QTY [I]": "439",
            "BASEMENTS [M]": "127,200.00",
            "GF & PODIUM [N]": "190,800.00",
            "TOWER 1 [O]": "723,450.00",
            "TOWER 2 [P]": "850,650.00",
            "TOWER 3 [Q]": "826,800.00",
            "TOWER 4 [R]": "771,150.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-B",
          "item_code": "B",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D22; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D22; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 658,
          "unit": "Nr.",
          "rate_aed": 4900,
          "amount_aed": 3224200,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "138",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "156",
            "Tower 4 [H]": "154",
            "TOTAL QTY [I]": "658",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "196,000.00",
            "TOWER 1 [O]": "676,200.00",
            "TOWER 2 [P]": "833,000.00",
            "TOWER 3 [Q]": "764,400.00",
            "TOWER 4 [R]": "754,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-C",
          "item_code": "C",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D23; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D23; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 433,
          "unit": "Nr.",
          "rate_aed": 4800,
          "amount_aed": 2078400,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "433",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "139,200.00",
            "TOWER 1 [O]": "436,800.00",
            "TOWER 2 [P]": "528,000.00",
            "TOWER 3 [Q]": "494,400.00",
            "TOWER 4 [R]": "480,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-D",
          "item_code": "D",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D25; size 1850 x 2200mm; single double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D25; size 1850 x 2200mm; single double leaf; 60mins FR",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 7250,
          "amount_aed": 94250,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "21,750.00",
            "TOWER 2 [P]": "29,000.00",
            "TOWER 3 [Q]": "21,750.00",
            "TOWER 4 [R]": "21,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-E",
          "item_code": "E",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D26; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D26; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 7900,
          "amount_aed": 63200,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,800.00",
            "TOWER 2 [P]": "15,800.00",
            "TOWER 3 [Q]": "15,800.00",
            "TOWER 4 [R]": "15,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-F",
          "item_code": "F",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D28; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D28; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 4800,
          "amount_aed": 28800,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "14,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-G",
          "item_code": "G",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D29; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D29; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7400,
          "amount_aed": 29600,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-H",
          "item_code": "H",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D42; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D42; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4800,
          "amount_aed": 9600,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-J",
          "item_code": "J",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D43; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; 54mm thick wooden door leaf; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D43; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5040,
          "amount_aed": 20160,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-K",
          "item_code": "K",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; with vision panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D30; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; with vision panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D30; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7850,
          "amount_aed": 7850,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-L",
          "item_code": "L",
          "section": "DOORS",
          "heading_path": [
            "Wood doors; with vision panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type D32; size 1900 x 2600mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Wood doors; with vision panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type D32; size 1900 x 2600mm; double leaf",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7520,
          "amount_aed": 15040,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-M",
          "item_code": "M",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-01; size 900 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-01; size 900 x 2200mm; single leaf",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1190,
          "amount_aed": 10710,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,380.00",
            "TOWER 2 [P]": "2,380.00",
            "TOWER 3 [Q]": "3,570.00",
            "TOWER 4 [R]": "2,380.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-N",
          "item_code": "N",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-02; size 1150 x 2050mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-02; size 1150 x 2050mm; single leaf; 60mins FR",
          "quantity": 226,
          "unit": "Nr.",
          "rate_aed": 1600,
          "amount_aed": 361600,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3335
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "54",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "50",
            "TOTAL QTY [I]": "226",
            "BASEMENTS [M]": "12,800.00",
            "GF & PODIUM [N]": "25,600.00",
            "TOWER 1 [O]": "73,600.00",
            "TOWER 2 [P]": "86,400.00",
            "TOWER 3 [Q]": "83,200.00",
            "TOWER 4 [R]": "80,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-P",
          "item_code": "P",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-02; size 1150 x 2050mm; single leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-02; size 1150 x 2050mm; single leaf; 90mins FR",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 3400,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,700.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,700.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-Q",
          "item_code": "Q",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1520,
          "amount_aed": 7600,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3339
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "3,040.00",
            "GF & PODIUM [N]": "3,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/59-R",
          "item_code": "R",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 35dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 35dB Rw",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1640,
          "amount_aed": 22960,
          "amount_state": "number",
          "printed_page": "2/H/3",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3341
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "13,120.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,280.00",
            "TOWER 2 [P]": "3,280.00",
            "TOWER 3 [Q]": "1,640.00",
            "TOWER 4 [R]": "1,640.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/60",
      "section": "DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 1765530,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/60-A",
          "item_code": "A",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 1670,
          "amount_aed": 20040,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,010.00",
            "TOWER 1 [O]": "1,670.00",
            "TOWER 2 [P]": "3,340.00",
            "TOWER 3 [Q]": "1,670.00",
            "TOWER 4 [R]": "8,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-B",
          "item_code": "B",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR; 35dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR; 35dB Rw",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1790,
          "amount_aed": 19690,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3352
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "14,320.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,790.00",
            "TOWER 2 [P]": "1,790.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,790.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-C",
          "item_code": "C",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 60mins FR; 45dB Rw",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1840,
          "amount_aed": 1840,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3354
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-D",
          "item_code": "D",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR",
          "quantity": 720,
          "unit": "Nr.",
          "rate_aed": 1830,
          "amount_aed": 1317600,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3356
          },
          "extra_columns": {
            "Basement [C]": "30",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "145",
            "Tower 2 [F]": "173",
            "Tower 3 [G]": "163",
            "Tower 4 [H]": "153",
            "TOTAL QTY [I]": "720",
            "BASEMENTS [M]": "54,900.00",
            "GF & PODIUM [N]": "102,480.00",
            "TOWER 1 [O]": "265,350.00",
            "TOWER 2 [P]": "316,590.00",
            "TOWER 3 [Q]": "298,290.00",
            "TOWER 4 [R]": "279,990.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-E",
          "item_code": "E",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 35dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 35dB Rw",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1950,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-F",
          "item_code": "F",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "quantity": 57,
          "unit": "Nr.",
          "rate_aed": 1960,
          "amount_aed": 111720,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3360
          },
          "extra_columns": {
            "Basement [C]": "28",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "54,880.00",
            "GF & PODIUM [N]": "21,560.00",
            "TOWER 1 [O]": "13,720.00",
            "TOWER 2 [P]": "7,840.00",
            "TOWER 3 [Q]": "5,880.00",
            "TOWER 4 [R]": "7,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-G",
          "item_code": "G",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-04; size 1150 x 2200mm; single leaf; 90mins FR; 45dB Rw",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1980,
          "amount_aed": 17820,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3362
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "3,960.00",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "1,980.00",
            "TOWER 2 [P]": "3,960.00",
            "TOWER 3 [Q]": "1,980.00",
            "TOWER 4 [R]": "3,960.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-H",
          "item_code": "H",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-05; size 1150 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-05; size 1150 x 2200mm; single leaf",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1520,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3364
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-J",
          "item_code": "J",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-05; size 1150 x 2200mm; single leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-05; size 1150 x 2200mm; single leaf; 90mins FR",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1820,
          "amount_aed": 5460,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3366
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-K",
          "item_code": "K",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-05; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-05; size 1150 x 2200mm; single leaf; 90mins FR; 40dB Rw",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1820,
          "amount_aed": 25480,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-L",
          "item_code": "L",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-06; size 1900 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-06; size 1900 x 2200mm; double leaf",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2510,
          "amount_aed": 15060,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3370
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "5,020.00",
            "GF & PODIUM [N]": "10,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-M",
          "item_code": "M",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-06; size 1900 x 2200mm; double leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-06; size 1900 x 2200mm; double leaf; 60mins FR",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 2760,
          "amount_aed": 93840,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3372
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "24,840.00",
            "GF & PODIUM [N]": "69,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-N",
          "item_code": "N",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-06; size 1900 x 2200mm; double leaf; 60mins FR; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-06; size 1900 x 2200mm; double leaf; 60mins FR; 45dB Rw",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2990,
          "amount_aed": 14950,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3374
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,990.00",
            "TOWER 1 [O]": "2,990.00",
            "TOWER 2 [P]": "2,990.00",
            "TOWER 3 [Q]": "2,990.00",
            "TOWER 4 [R]": "2,990.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-P",
          "item_code": "P",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-06; size 1900 x 2200mm; double leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-06; size 1900 x 2200mm; double leaf; 90mins FR",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 3010,
          "amount_aed": 57190,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3376
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "6,020.00",
            "GF & PODIUM [N]": "51,170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-Q",
          "item_code": "Q",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-06; size 1900 x 2200mm; double leaf; 90mins FR; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-06; size 1900 x 2200mm; double leaf; 90mins FR; 45dB Rw",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 3240,
          "amount_aed": 35640,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3378
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "6,480.00",
            "GF & PODIUM [N]": "16,200.00",
            "TOWER 1 [O]": "3,240.00",
            "TOWER 2 [P]": "3,240.00",
            "TOWER 3 [Q]": "3,240.00",
            "TOWER 4 [R]": "3,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-R",
          "item_code": "R",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-07; size 1850 x 2200mm; double leaf; 90mins FR; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-07; size 1850 x 2200mm; double leaf; 90mins FR; 45dB Rw",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3160,
          "amount_aed": 3160,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3380
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-S",
          "item_code": "S",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-08; size 1850 x 2500mm; double leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-08; size 1850 x 2500mm; double leaf; 90mins FR",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 3330,
          "amount_aed": 16650,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3382
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-T",
          "item_code": "T",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-09; size 800 x 800mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-09; size 800 x 800mm; single leaf",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 380,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3384
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-U",
          "item_code": "U",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-10; size 800 x 1000mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-10; size 800 x 1000mm; single leaf",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3386
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "480.00",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/60-V",
          "item_code": "V",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-10; size 800 x 1000mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-10; size 800 x 1000mm; single leaf; 60mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 530,
          "amount_aed": 530,
          "amount_state": "number",
          "printed_page": "2/H/4",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3388
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "530.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/61",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 1660330,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/61-A",
          "item_code": "A",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-11; size 900 x 900mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-11; size 900 x 900mm; single leaf",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 490,
          "amount_aed": 5880,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3397
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "4,900.00",
            "GF & PODIUM [N]": "980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-B",
          "item_code": "B",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-12; size 900 x 1200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-12; size 900 x 1200mm; single leaf; 60mins FR",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 710,
          "amount_aed": 2840,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "710.00",
            "TOWER 2 [P]": "710.00",
            "TOWER 3 [Q]": "710.00",
            "TOWER 4 [R]": "710.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-C",
          "item_code": "C",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-13; size 3500 x 2200mm; four leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-13; size 3500 x 2200mm; four leaf; 90mins FR",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 5540,
          "amount_aed": 27700,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3401
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "5,540.00",
            "GF & PODIUM [N]": "22,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-D",
          "item_code": "D",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-14; size 3000 x 2200mm; four leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-14; size 3000 x 2200mm; four leaf; 90mins FR",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 14250,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3403
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "9,500.00",
            "GF & PODIUM [N]": "4,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-E",
          "item_code": "E",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DS-15; size 2000 x 2200mm; four leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; stove enamel steel door; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DS-15; size 2000 x 2200mm; four leaf; 90mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3170,
          "amount_aed": 3170,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-F",
          "item_code": "F",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DA-02; size 1150 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DA-02; size 1150 x 2200mm; single leaf",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1520,
          "amount_aed": 9120,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-G",
          "item_code": "G",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DA-02; size 1150 x 2200mm; single leaf; 60mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DA-02; size 1150 x 2200mm; single leaf; 60mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1670,
          "amount_aed": 1670,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-H",
          "item_code": "H",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DA-02; size 1150 x 2200mm; single leaf; 35dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DA-02; size 1150 x 2200mm; single leaf; 35dB Rw",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1640,
          "amount_aed": 3280,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-J",
          "item_code": "J",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DA-08; size 1100 x 2200mm; single leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DA-08; size 1100 x 2200mm; single leaf",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1450,
          "amount_aed": 8700,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-K",
          "item_code": "K",
          "section": "DOORS",
          "heading_path": [
            "Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DA-08; size 1100 x 2200mm; single leaf; 45dB Rw",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Steel doors; powder coated aluminium sandwich panel; building into brick, block concrete walls and gypsum partitions; including frames, finishes, ironmongery (measured separately), architrave, weatherstripping, accessories and all ancillary works as necessary — Type DA-08; size 1100 x 2200mm; single leaf; 45dB Rw",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1610,
          "amount_aed": 3220,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-L",
          "item_code": "L",
          "section": "DOORS",
          "heading_path": [
            "Glass door; double glazed fully tempered & heat soak tested clear glass panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DG-18; size 1900 x 2200mm; double leaf; 90mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Glass door; double glazed fully tempered & heat soak tested clear glass panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type DG-18; size 1900 x 2200mm; double leaf; 90mins FR",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 11750,
          "amount_aed": 23500,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-M",
          "item_code": "M",
          "section": "DOORS",
          "heading_path": [
            "Glass door; double glazed fully tempered & heat soak tested clear glass panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type DG-19; size 1900 x 2200mm; double leaf",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — DOORS — Glass door; double glazed fully tempered & heat soak tested clear glass panel; building into brick, block concrete walls and gypsum partitions; including frames, ironmongery, architrave, weatherstripping, accessories and all ancillary works as necessary — Type DG-19; size 1900 x 2200mm; double leaf",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 10020,
          "amount_aed": 260520,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3423
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "160,320.00",
            "GF & PODIUM [N]": "100,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CW-01; size 5000 x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary — Type CW-01; size 5000 x 2600mm high",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 22750,
          "amount_aed": 546000,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3429
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "8",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "364,000.00",
            "GF & PODIUM [N]": "182,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-P",
          "item_code": "P",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CW-02; size 3000 x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary — Type CW-02; size 3000 x 2600mm high",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 13650,
          "amount_aed": 682500,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3431
          },
          "extra_columns": {
            "Basement [C]": "32",
            "GF & Podium [D]": "18",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "436,800.00",
            "GF & PODIUM [N]": "245,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-Q",
          "item_code": "Q",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CW-03; size 4800 x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary — Type CW-03; size 4800 x 2600mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 21840,
          "amount_aed": 43680,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3433
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/61-R",
          "item_code": "R",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-01; size 1850 x 1250mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, fixings, fittings, accessories and all ancillary works as necessary — Type WD-01; size 1850 x 1250mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 4050,
          "amount_aed": 24300,
          "amount_state": "number",
          "printed_page": "2/H/5",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3435
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/62",
      "section": "EXTERNAL DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 223330,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/62-A",
          "item_code": "A",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 60 mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 60 mins FR",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3290,
          "amount_aed": 13160,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3448
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,290.00",
            "TOWER 2 [P]": "3,290.00",
            "TOWER 3 [Q]": "3,290.00",
            "TOWER 4 [R]": "3,290.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-B",
          "item_code": "B",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 60 mins FR; Rw 35dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 60 mins FR; Rw 35dB",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4810,
          "amount_aed": 19240,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3450
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,810.00",
            "TOWER 2 [P]": "4,810.00",
            "TOWER 3 [Q]": "4,810.00",
            "TOWER 4 [R]": "4,810.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-C",
          "item_code": "C",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 90 mins FR  ; Rw 40dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 90 mins FR  ; Rw 40dB",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 4810,
          "amount_aed": 48100,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3452
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,430.00",
            "TOWER 2 [P]": "14,430.00",
            "TOWER 3 [Q]": "9,620.00",
            "TOWER 4 [R]": "9,620.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-D",
          "item_code": "D",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 90 mins FR  ; Rw 45dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; 90 mins FR  ; Rw 45dB",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4810,
          "amount_aed": 19240,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3454
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,810.00",
            "TOWER 2 [P]": "4,810.00",
            "TOWER 3 [Q]": "4,810.00",
            "TOWER 4 [R]": "4,810.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-E",
          "item_code": "E",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; Rw 35dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-04; size; 1150mm width x 2200mm high; single leaf swing door; Rw 35dB",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 4810,
          "amount_aed": 28860,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3456
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,620.00",
            "TOWER 2 [P]": "9,620.00",
            "TOWER 3 [Q]": "4,810.00",
            "TOWER 4 [R]": "4,810.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-F",
          "item_code": "F",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-06; size; 1900mm width x 2200mm high; double leaf swing door; 60 mins FR; Rw 45dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-06; size; 1900mm width x 2200mm high; double leaf swing door; 60 mins FR; Rw 45dB",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7940,
          "amount_aed": 31760,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3460
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,940.00",
            "TOWER 2 [P]": "7,940.00",
            "TOWER 3 [Q]": "7,940.00",
            "TOWER 4 [R]": "7,940.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-G",
          "item_code": "G",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DS-06; size; 1900mm width x 2200mm high; double leaf swing door; 90 mins FR  ; Rw 45dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Steel door set ; with steel frame; finished colour: RAL 7047 Stove Enamel; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DS-06; size; 1900mm width x 2200mm high; double leaf swing door; 90 mins FR  ; Rw 45dB",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7940,
          "amount_aed": 31760,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3462
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,940.00",
            "TOWER 2 [P]": "7,940.00",
            "TOWER 3 [Q]": "7,940.00",
            "TOWER 4 [R]": "7,940.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-H",
          "item_code": "H",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2280,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3468
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-J",
          "item_code": "J",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door; 90 mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door; 90 mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3040,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3470
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-K",
          "item_code": "K",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door; Rw 40dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-01; size; 2200mm width x 1150mm high; single leaf swing door; Rw 40dB",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4810,
          "amount_aed": 9620,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3472
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-L",
          "item_code": "L",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-02; size; 2200mm width x 1150mm high; single leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-02; size; 2200mm width x 1150mm high; single leaf swing door",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2280,
          "amount_aed": 11400,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3474
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/62-M",
          "item_code": "M",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-08; size; 2500mm width x 1149mm high; single leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-08; size; 2500mm width x 1149mm high; single leaf swing door",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2590,
          "amount_aed": 2590,
          "amount_state": "number",
          "printed_page": "2/H/6",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3476
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,590.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/63",
      "section": "EXTERNAL DOORS",
      "sheet": "2 - Main",
      "source_collection_aed": 1234650,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/63-A",
          "item_code": "A",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-03; size; 2200mm width x 1900mm high; double leaf swing door; Rw 45dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-03; size; 2200mm width x 1900mm high; double leaf swing door; Rw 45dB",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9030,
          "amount_aed": 9030,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3487
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-B",
          "item_code": "B",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-04; size; 2200mm width x 1500mm high; double leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-04; size; 2200mm width x 1500mm high; double leaf swing door",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3380,
          "amount_aed": 3380,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3489
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-C",
          "item_code": "C",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4280,
          "amount_aed": 4280,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3491
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-D",
          "item_code": "D",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door; 90 mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door; 90 mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5700,
          "amount_aed": 5700,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3493
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-E",
          "item_code": "E",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door; 90 mins FR  ; Rw 40dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-05; size; 2200mm width x 1900mm high; double leaf swing door; 90 mins FR  ; Rw 40dB",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9030,
          "amount_aed": 9030,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3495
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-F",
          "item_code": "F",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-06; size; 2500mm width x 2200mm high; double leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-06; size; 2500mm width x 2200mm high; double leaf swing door",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3497
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-G",
          "item_code": "G",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-07; size; 3500mm width x 2400mm high; double leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-07; size; 3500mm width x 2400mm high; double leaf swing door",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7560,
          "amount_aed": 7560,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3499
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-H",
          "item_code": "H",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-08; size; 2550mm width x 1150mm high; single leaf swing door",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-08; size; 2550mm width x 1150mm high; single leaf swing door",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2640,
          "amount_aed": 15840,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3505
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-J",
          "item_code": "J",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Single leaf"
          ],
          "own_description": "Type DA-08; size; 2550mm width x 1150mm high; single leaf swing door; 90 mins FR",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Single leaf — Type DA-08; size; 2550mm width x 1150mm high; single leaf swing door; 90 mins FR",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3507
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-K",
          "item_code": "K",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings",
            "Double leaf"
          ],
          "own_description": "Type DA-09; size; 2200mm width x 1900mm high; double leaf swing door; Rw 45dB",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminum door set ; with aluminum frame and sandwich panel/louvered infill; finished colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery (measured separately) and all necessary accessories; size to suit structural openings — Double leaf — Type DA-09; size; 2200mm width x 1900mm high; double leaf swing door; Rw 45dB",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7520,
          "amount_aed": 7520,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3511
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-L",
          "item_code": "L",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Aluminium roller shutter; colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery and all necessary accessories; size to suit structural openings"
          ],
          "own_description": "Type RS-01; size; 4100mm width x 3600mm high; roller shutter",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Aluminium roller shutter; colour: RAL 7043; including frames, sub-frame, jamb, head, insulation, seal, finishes, ironmongery and all necessary accessories; size to suit structural openings — Type RS-01; size; 4100mm width x 3600mm high; roller shutter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 15350,
          "amount_aed": 61400,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3515
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "61,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/63-M",
          "item_code": "M",
          "section": "EXTERNAL DOORS",
          "heading_path": [
            "Revolving door; including frames, insulation, seal, finishes, ironmongery and all necessary accessories"
          ],
          "own_description": "Revolving door; size 3000mm dia x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — EXTERNAL DOORS — Revolving door; including frames, insulation, seal, finishes, ironmongery and all necessary accessories — Revolving door; size 3000mm dia x 3100mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 275610,
          "amount_aed": 1102440,
          "amount_state": "number",
          "printed_page": "2/H/7",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3519
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,102,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/64",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 83332190,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/64-A",
          "item_code": "A",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area",
          "quantity": 43198,
          "unit": "m2",
          "rate_aed": 1400,
          "amount_aed": 60477200,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3532
          },
          "extra_columns": {
            "GF & Podium [D]": "1,345",
            "Tower 1 [E]": "9,716",
            "Tower 2 [F]": "14,335",
            "Tower 3 [G]": "10,995",
            "Tower 4 [H]": "6,807",
            "TOTAL QTY [I]": "43,198",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,883,000.00",
            "TOWER 1 [O]": "13,602,400.00",
            "TOWER 2 [P]": "20,069,000.00",
            "TOWER 3 [Q]": "15,393,000.00",
            "TOWER 4 [R]": "9,529,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-B",
          "item_code": "B",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area; curved corner",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area; curved corner",
          "quantity": 2695,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 4042500,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3534
          },
          "extra_columns": {
            "GF & Podium [D]": "101",
            "Tower 1 [E]": "1,222",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1,372",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,695",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "151,500.00",
            "TOWER 1 [O]": "1,833,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,058,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-C",
          "item_code": "C",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-06; size 1100mm width x 2950mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-06; size 1100mm width x 2950mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2990,
          "amount_aed": 2990,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3536
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-D",
          "item_code": "D",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-10; size 1750mm width x 2950mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-10; size 1750mm width x 2950mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 9500,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3538
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-E",
          "item_code": "E",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-12; size 1900mm width x 2575mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-12; size 1900mm width x 2575mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4500,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3540
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-F",
          "item_code": "F",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; size 2000mm width x 2950mm high; type DG-11",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; size 2000mm width x 2950mm high; type DG-11",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 4500,
          "amount_aed": 13500,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3542
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-G",
          "item_code": "G",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 950mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 950mm width x 3100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2710,
          "amount_aed": 2710,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3544
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,710.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-H",
          "item_code": "H",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-01",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-01",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 9500,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3546
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-J",
          "item_code": "J",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-05",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3548
          },
          "extra_columns": {
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-K",
          "item_code": "K",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1950mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1950mm width x 2600mm high",
          "quantity": 879,
          "unit": "Nr.",
          "rate_aed": 5580,
          "amount_aed": 4904820,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3550
          },
          "extra_columns": {
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "176",
            "Tower 2 [F]": "328",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "152",
            "TOTAL QTY [I]": "879",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "128,340.00",
            "TOWER 1 [O]": "982,080.00",
            "TOWER 2 [P]": "1,830,240.00",
            "TOWER 3 [Q]": "1,116,000.00",
            "TOWER 4 [R]": "848,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-L",
          "item_code": "L",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1990mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1990mm width x 2600mm high",
          "quantity": 381,
          "unit": "Nr.",
          "rate_aed": 5690,
          "amount_aed": 2167890,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3552
          },
          "extra_columns": {
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "172",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "196",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "381",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "73,970.00",
            "TOWER 1 [O]": "978,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,115,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-M",
          "item_code": "M",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2050mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2050mm width x 2600mm high",
          "quantity": 1267,
          "unit": "Nr.",
          "rate_aed": 5860,
          "amount_aed": 7424620,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3554
          },
          "extra_columns": {
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "573",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "651",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,267",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "251,980.00",
            "TOWER 1 [O]": "3,357,780.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,814,860.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2150mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2150mm width x 2600mm high",
          "quantity": 255,
          "unit": "Nr.",
          "rate_aed": 6150,
          "amount_aed": 1568250,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3556
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "172",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "76",
            "TOTAL QTY [I]": "255",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,057,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "467,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-P",
          "item_code": "P",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2270mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2270mm width x 2600mm high",
          "quantity": 240,
          "unit": "Nr.",
          "rate_aed": 6490,
          "amount_aed": 1557600,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3558
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "160",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "72",
            "TOTAL QTY [I]": "240",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,038,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "467,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-Q",
          "item_code": "Q",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1950mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1950mm width x 2750mm high",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 5900,
          "amount_aed": 141600,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3560
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "23,600.00",
            "TOWER 2 [P]": "94,400.00",
            "TOWER 3 [Q]": "23,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-R",
          "item_code": "R",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1990mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1990mm width x 2750mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 6020,
          "amount_aed": 48160,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3562
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "24,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-S",
          "item_code": "S",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2050mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2050mm width x 2750mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 6200,
          "amount_aed": 161200,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3564
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "80,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-T",
          "item_code": "T",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2150mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2150mm width x 2750mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 52000,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3566
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "52,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-U",
          "item_code": "U",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2270mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2270mm width x 2750mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 6870,
          "amount_aed": 54960,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3568
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "54,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-V",
          "item_code": "V",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1950mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1950mm width x 3100mm high",
          "quantity": 84,
          "unit": "Nr.",
          "rate_aed": 6650,
          "amount_aed": 558600,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3570
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "57",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "19,950.00",
            "TOWER 2 [P]": "379,050.00",
            "TOWER 3 [Q]": "19,950.00",
            "TOWER 4 [R]": "139,650.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/64-W",
          "item_code": "W",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2050mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2050mm width x 3100mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6990,
          "amount_aed": 111840,
          "amount_state": "number",
          "printed_page": "2/H/8",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3572
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "8",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "55,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "55,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/65",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 2595930,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/65-A",
          "item_code": "A",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2150mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2150mm width x 3100mm high",
          "quantity": 75,
          "unit": "Nr.",
          "rate_aed": 7330,
          "amount_aed": 549750,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3581
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "29,320.00",
            "TOWER 2 [P]": "315,190.00",
            "TOWER 3 [Q]": "29,320.00",
            "TOWER 4 [R]": "175,920.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-B",
          "item_code": "B",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2270mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2270mm width x 3100mm high",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 7740,
          "amount_aed": 263160,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3583
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "23",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "178,020.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "85,140.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-C",
          "item_code": "C",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 5200mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 5200mm width x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 17730,
          "amount_aed": 35460,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3585
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,730.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,730.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-D",
          "item_code": "D",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 59500mm 5950mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 59500mm 5950mm width x 3100mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 20290,
          "amount_aed": 324640,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3587
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "162,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "162,320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-E",
          "item_code": "E",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 875mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 875mm width x 1325mm high",
          "quantity": 347,
          "unit": "Nr.",
          "rate_aed": 830,
          "amount_aed": 288010,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3589
          },
          "extra_columns": {
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "152",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "176",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "347",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,770.00",
            "TOWER 1 [O]": "126,160.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "146,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-F",
          "item_code": "F",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 930mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 930mm width x 1325mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 890,
          "amount_aed": 890,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3591
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "890.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-G",
          "item_code": "G",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1325mm high",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 910,
          "amount_aed": 6370,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3593
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,370.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-H",
          "item_code": "H",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1325mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 930,
          "amount_aed": 7440,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3595
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-J",
          "item_code": "J",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 985mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 985mm width x 1325mm high",
          "quantity": 145,
          "unit": "Nr.",
          "rate_aed": 940,
          "amount_aed": 136300,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3597
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "68",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "74",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "145",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,820.00",
            "TOWER 1 [O]": "63,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "69,560.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-K",
          "item_code": "K",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 1040mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 1040mm width x 1325mm high",
          "quantity": 191,
          "unit": "Nr.",
          "rate_aed": 990,
          "amount_aed": 189090,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3599
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "191",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,970.00",
            "TOWER 1 [O]": "87,120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "99,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-L",
          "item_code": "L",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1420mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1420mm high",
          "quantity": 412,
          "unit": "Nr.",
          "rate_aed": 970,
          "amount_aed": 399640,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3601
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "296",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "116",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "287,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "112,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-M",
          "item_code": "M",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1420mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1420mm high",
          "quantity": 240,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 240000,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3603
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "164",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "76",
            "TOTAL QTY [I]": "240",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "164,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 875mm width x 1475mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 875mm width x 1475mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 930,
          "amount_aed": 5580,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3605
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,790.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,790.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-P",
          "item_code": "P",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 985mm width x 1475mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 985mm width x 1475mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1050,
          "amount_aed": 4200,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3607
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-Q",
          "item_code": "Q",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 1040mm width x 1475mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 1040mm width x 1475mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3609
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-R",
          "item_code": "R",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1570mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1570mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1010,
          "amount_aed": 6060,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3611
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,060.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-S",
          "item_code": "S",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1570mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1570mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3613
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/65-T",
          "item_code": "T",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1900mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1900mm high",
          "quantity": 122,
          "unit": "Nr.",
          "rate_aed": 1070,
          "amount_aed": 130540,
          "amount_state": "number",
          "printed_page": "2/H/9",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3615
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "78",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "122",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,140.00",
            "TOWER 2 [P]": "83,460.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "44,940.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/66",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 12146200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/66-A",
          "item_code": "A",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1900mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1900mm high",
          "quantity": 60,
          "unit": "Nr.",
          "rate_aed": 1330,
          "amount_aed": 79800,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3624
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,870.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,930.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-B",
          "item_code": "B",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 955mm width x 1900mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 955mm width x 1900mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1310,
          "amount_aed": 2620,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3626
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,620.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-C",
          "item_code": "C",
          "section": "SCREENS",
          "heading_path": [
            "External",
            "Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 1065mm width x 1900mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — External — Double glazed vision panel screen; Type V1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 1065mm width x 1900mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1460,
          "amount_aed": 37960,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3628
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "27,740.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,220.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-D",
          "item_code": "D",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area",
          "quantity": 6838,
          "unit": "m2",
          "rate_aed": 1400,
          "amount_aed": 9573200,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3632
          },
          "extra_columns": {
            "GF & Podium [D]": "518",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "6,320",
            "TOTAL QTY [I]": "6,838",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "725,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,848,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-E",
          "item_code": "E",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-05",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1000mm width x 2700mm high; type DG-05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3634
          },
          "extra_columns": {
            "Tower 4 [H]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-F",
          "item_code": "F",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; size 2000mm width x 2700mm high; type DG-12",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; size 2000mm width x 2700mm high; type DG-12",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4500,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3636
          },
          "extra_columns": {
            "Tower 4 [H]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-G",
          "item_code": "G",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1950mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1950mm width x 2600mm high",
          "quantity": 201,
          "unit": "Nr.",
          "rate_aed": 4660,
          "amount_aed": 936660,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3638
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "192",
            "TOTAL QTY [I]": "201",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "41,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "894,720.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-H",
          "item_code": "H",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2150mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2150mm width x 2600mm high",
          "quantity": 105,
          "unit": "Nr.",
          "rate_aed": 5140,
          "amount_aed": 539700,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3640
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "96",
            "TOTAL QTY [I]": "105",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "46,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "493,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-J",
          "item_code": "J",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2270mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2270mm width x 2600mm high",
          "quantity": 104,
          "unit": "Nr.",
          "rate_aed": 5430,
          "amount_aed": 564720,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3642
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "96",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "521,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-K",
          "item_code": "K",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 1950mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 1950mm width x 2750mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 4930,
          "amount_aed": 39440,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3644
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "39,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-L",
          "item_code": "L",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2150mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2150mm width x 2750mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5440,
          "amount_aed": 21760,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3646
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-M",
          "item_code": "M",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for sliding door; size 2270mm width x 2750mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for sliding door; size 2270mm width x 2750mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5740,
          "amount_aed": 22960,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3648
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "22,960.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1325mm high",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 910,
          "amount_aed": 14560,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3650
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-P",
          "item_code": "P",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1325mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1325mm high",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 930,
          "amount_aed": 8370,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3652
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,370.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-Q",
          "item_code": "Q",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1420mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1420mm high",
          "quantity": 192,
          "unit": "Nr.",
          "rate_aed": 970,
          "amount_aed": 186240,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3654
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "192",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "186,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-R",
          "item_code": "R",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1420mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1420mm high",
          "quantity": 96,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 96000,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3656
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "96",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "96,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-S",
          "item_code": "S",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 950mm width x 1570mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 950mm width x 1570mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1070,
          "amount_aed": 8560,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3658
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/66-T",
          "item_code": "T",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for top hung window; size 975mm width x 1570mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V2; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.7W/m²K; Shading coefficient 0.25 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for top hung window; size 975mm width x 1570mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/H/10",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3660
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,400.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/67",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 1414780,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/67-A",
          "item_code": "A",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area",
          "quantity": 820,
          "unit": "m2",
          "rate_aed": 1400,
          "amount_aed": 1148000,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3672
          },
          "extra_columns": {
            "GF & Podium [D]": "820",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "820",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,148,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-B",
          "item_code": "B",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area; curved corner",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area; curved corner",
          "quantity": 25,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 37500,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3674
          },
          "extra_columns": {
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-C",
          "item_code": "C",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-01; size 900mm width x 2575mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-01; size 900mm width x 2575mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2130,
          "amount_aed": 8520,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3676
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-D",
          "item_code": "D",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-03; size 980mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-03; size 980mm width x 3075mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2770,
          "amount_aed": 5540,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3678
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-E",
          "item_code": "E",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-07; size 1100mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-07; size 1100mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3110,
          "amount_aed": 3110,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3680
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-F",
          "item_code": "F",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-08; size 1150mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-08; size 1150mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3250,
          "amount_aed": 3250,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3682
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-G",
          "item_code": "G",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-13; size 2150mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-13; size 2150mm width x 3075mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 6080,
          "amount_aed": 48640,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3684
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-H",
          "item_code": "H",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-14 size 2025mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-14 size 2025mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5730,
          "amount_aed": 5730,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3686
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,730.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-J",
          "item_code": "J",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-16; size 1725mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-16; size 1725mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4880,
          "amount_aed": 4880,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3688
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-K",
          "item_code": "K",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-20; size 1950mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V3; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-20; size 1950mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5520,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3690
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-L",
          "item_code": "L",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Vision panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Vision panel area",
          "quantity": 97,
          "unit": "m2",
          "rate_aed": 1400,
          "amount_aed": 135800,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3694
          },
          "extra_columns": {
            "GF & Podium [D]": "97",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "97",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "135,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-M",
          "item_code": "M",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-03; size 980mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-03; size 980mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2770,
          "amount_aed": 2770,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3696
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,770.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/67-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed vision panel screen; Type V4; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 8mm FT; U-value = 1.9W/m²K; Shading coefficient 0.76 max.; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, insulation, plaster board, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5520,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/H/11",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3698
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/68",
      "section": "SCREENS",
      "sheet": "2 - Main",
      "source_collection_aed": 34480750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/68-A",
          "item_code": "A",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Spandrel panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Spandrel panel area",
          "quantity": 19559,
          "unit": "m2",
          "rate_aed": 1700,
          "amount_aed": 33250300,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3710
          },
          "extra_columns": {
            "GF & Podium [D]": "1,855",
            "Tower 1 [E]": "3,962",
            "Tower 2 [F]": "4,958",
            "Tower 3 [G]": "4,337",
            "Tower 4 [H]": "4,447",
            "TOTAL QTY [I]": "19,559",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,153,500.00",
            "TOWER 1 [O]": "6,735,400.00",
            "TOWER 2 [P]": "8,428,600.00",
            "TOWER 3 [Q]": "7,372,900.00",
            "TOWER 4 [R]": "7,559,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-B",
          "item_code": "B",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Spandrel panel area; curved corner",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Spandrel panel area; curved corner",
          "quantity": 335,
          "unit": "m2",
          "rate_aed": 1800,
          "amount_aed": 603000,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3712
          },
          "extra_columns": {
            "GF & Podium [D]": "55",
            "Tower 1 [E]": "140",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "140",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "335",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "99,000.00",
            "TOWER 1 [O]": "252,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "252,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-C",
          "item_code": "C",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1000mm width x 2950mm high; type DG-02",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1000mm width x 2950mm high; type DG-02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4750,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3714
          },
          "extra_columns": {
            "GF & Podium [D]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-D",
          "item_code": "D",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; Type DG-04; size 1050mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; Type DG-04; size 1050mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2970,
          "amount_aed": 2970,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3716
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-E",
          "item_code": "E",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 3500,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3718
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-F",
          "item_code": "F",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-17; size 1825mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-17; size 1825mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5160,
          "amount_aed": 5160,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3720
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-G",
          "item_code": "G",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 950mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 950mm width x 2600mm high",
          "quantity": 22,
          "unit": "Nr.",
          "rate_aed": 2270,
          "amount_aed": 49940,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3722
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "8",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,160.00",
            "TOWER 2 [P]": "4,540.00",
            "TOWER 3 [Q]": "18,160.00",
            "TOWER 4 [R]": "9,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-H",
          "item_code": "H",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1000mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1000mm width x 2600mm high",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 2390,
          "amount_aed": 33460,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3724
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,340.00",
            "TOWER 3 [Q]": "9,560.00",
            "TOWER 4 [R]": "9,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-J",
          "item_code": "J",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1100mm width x 2600mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1100mm width x 2600mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2630,
          "amount_aed": 21040,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3726
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-K",
          "item_code": "K",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 950mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 950mm width x 3100mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2710,
          "amount_aed": 5420,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3728
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,710.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,710.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-L",
          "item_code": "L",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for single leaf swing door; size 1150mm width x 3100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S1; light smokey grey; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for single leaf swing door; size 1150mm width x 3100mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3280,
          "amount_aed": 13120,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3730
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-M",
          "item_code": "M",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Spandrel panel area",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Spandrel panel area",
          "quantity": 278,
          "unit": "m2",
          "rate_aed": 1700,
          "amount_aed": 472600,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3734
          },
          "extra_columns": {
            "GF & Podium [D]": "278",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "278",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "472,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-N",
          "item_code": "N",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-09 size 1500mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-09 size 1500mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4240,
          "amount_aed": 4240,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3736
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-P",
          "item_code": "P",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-14 size 2025mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-14 size 2025mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5730,
          "amount_aed": 5730,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3738
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,730.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/68-Q",
          "item_code": "Q",
          "section": "SCREENS",
          "heading_path": [
            "Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — SCREENS — Double glazed spandrel panel screen; Type S2; neutral clear; Buildup: IGU; Outer lite: 8mm FT, Low E coating on surface #2 + 16mm AS + Inner lite: 6mm FT; including frames, sub-frame, door system, finishes, joint, gasket, toggle clip, sealant, plaster board, insulation, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Extra over for double leaf swing door; Type DG-15; size 1950mm width x 3075mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5520,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/H/12",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3740
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/69",
      "section": "LOUVERS",
      "sheet": "2 - Main",
      "source_collection_aed": 5531370,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/69-A",
          "item_code": "A",
          "section": "LOUVERS",
          "heading_path": [
            "External",
            "Architectural Aluminium louvers; Type AL-11; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "Louver type AL-11",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — External — Architectural Aluminium louvers; Type AL-11; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — Louver type AL-11",
          "quantity": 3141,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 4711500,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3756
          },
          "extra_columns": {
            "GF & Podium [D]": "2,841",
            "Tower 1 [E]": "68",
            "Tower 2 [F]": "89",
            "Tower 3 [G]": "68",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "3,141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,261,500.00",
            "TOWER 1 [O]": "102,000.00",
            "TOWER 2 [P]": "133,500.00",
            "TOWER 3 [Q]": "102,000.00",
            "TOWER 4 [R]": "112,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-B",
          "item_code": "B",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-01: 4100mm width x 2100mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-01: 4100mm width x 2100mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12050,
          "amount_aed": 12050,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3760
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-C",
          "item_code": "C",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-02: 13050mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-02: 13050mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 81300,
          "amount_aed": 81300,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3762
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "81,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-D",
          "item_code": "D",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-03: 9775mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-03: 9775mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 60900,
          "amount_aed": 60900,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3764
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-E",
          "item_code": "E",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-04: 29510mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-04: 29510mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 183850,
          "amount_aed": 183850,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3766
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "183,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-F",
          "item_code": "F",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-05: 4700mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-05: 4700mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 29280,
          "amount_aed": 29280,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3768
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-G",
          "item_code": "G",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-06: 13575mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-06: 13575mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 84570,
          "amount_aed": 84570,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3770
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "84,570.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-H",
          "item_code": "H",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-07: 10050mm width x 4450mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-07: 10050mm width x 4450mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 62610,
          "amount_aed": 62610,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3772
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "62,610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-J",
          "item_code": "J",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-08: 8100mm width x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-08: 8100mm width x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58740,
          "amount_aed": 58740,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3774
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,740.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-K",
          "item_code": "K",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-09: 6300mm width  x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-09: 6300mm width  x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 45690,
          "amount_aed": 45690,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3776
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,690.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-L",
          "item_code": "L",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-10: 8100mm width  x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-10: 8100mm width  x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58740,
          "amount_aed": 58740,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3778
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,740.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-M",
          "item_code": "M",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-11: 7500mm width  x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-11: 7500mm width  x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 54390,
          "amount_aed": 54390,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3780
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "54,390.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-N",
          "item_code": "N",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-12: 4500mm width  x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-12: 4500mm width  x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32630,
          "amount_aed": 32630,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3782
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/69-P",
          "item_code": "P",
          "section": "LOUVERS",
          "heading_path": [
            "Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications"
          ],
          "own_description": "LA-13: 7600mm width  x 5180mm high",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — LOUVERS — Aluminum louvers; Type AL-12; PVDF coated; colour: RAL 7043 (Tele Grey B); matte finish; including all ironmongery, fixings, fittings, accessories and all ancillary works as per drawings and specifications — LA-13: 7600mm width  x 5180mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 55120,
          "amount_aed": 55120,
          "amount_state": "number",
          "printed_page": "2/H/13",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3784
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "55,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/70",
      "section": "IRONMONGERY",
      "sheet": "2 - Main",
      "source_collection_aed": 1395312,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/70-A",
          "item_code": "A",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set D",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set D",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 11700,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3806
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-B",
          "item_code": "B",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set E",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set E",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3808
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-C",
          "item_code": "C",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set K",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set K",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3810
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-D",
          "item_code": "D",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set L",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set L",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 5400,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3812
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-E",
          "item_code": "E",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set M",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set M",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3814
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-F",
          "item_code": "F",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary",
            "Wood doors; single leaf"
          ],
          "own_description": "Hardware set N",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; internal doors; including fixings, accessories and all ancillary works as necessary — Wood doors; single leaf — Hardware set N",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3816
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-G",
          "item_code": "G",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set A",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set A",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 2282,
          "amount_aed": 36512,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3820
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,512.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-H",
          "item_code": "H",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set D",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set D",
          "quantity": 84,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 100800,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3822
          },
          "extra_columns": {
            "Basement [C]": "40",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "48,000.00",
            "GF & PODIUM [N]": "33,600.00",
            "TOWER 1 [O]": "6,000.00",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-J",
          "item_code": "J",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set E",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set E",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3824
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-K",
          "item_code": "K",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set G",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set G",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 19200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3826
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,600.00",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "2,400.00",
            "TOWER 4 [R]": "2,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-L",
          "item_code": "L",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set H",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set H",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3828
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "3,600.00",
            "GF & PODIUM [N]": "3,600.00",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "1,200.00",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-M",
          "item_code": "M",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set J",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set J",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3830
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-N",
          "item_code": "N",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set L",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set L",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3832
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "12,000.00",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-P",
          "item_code": "P",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set N",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set N",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3834
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "2,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-Q",
          "item_code": "Q",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set P",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set P",
          "quantity": 488,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 585600,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3836
          },
          "extra_columns": {
            "Basement [C]": "25",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "113",
            "Tower 3 [G]": "110",
            "Tower 4 [H]": "105",
            "TOTAL QTY [I]": "488",
            "BASEMENTS [M]": "30,000.00",
            "GF & PODIUM [N]": "44,400.00",
            "TOWER 1 [O]": "117,600.00",
            "TOWER 2 [P]": "135,600.00",
            "TOWER 3 [Q]": "132,000.00",
            "TOWER 4 [R]": "126,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-R",
          "item_code": "R",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set T",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set T",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 25200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3838
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "12,000.00",
            "GF & PODIUM [N]": "7,200.00",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "1,200.00",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-S",
          "item_code": "S",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set U",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set U",
          "quantity": 234,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 280800,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3840
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "56",
            "Tower 3 [G]": "54",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "234",
            "BASEMENTS [M]": "9,600.00",
            "GF & PODIUM [N]": "19,200.00",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "67,200.00",
            "TOWER 3 [Q]": "64,800.00",
            "TOWER 4 [R]": "62,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-T",
          "item_code": "T",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set V",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set V",
          "quantity": 226,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 271200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3842
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "58",
            "Tower 3 [G]": "55",
            "Tower 4 [H]": "53",
            "TOTAL QTY [I]": "226",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,400.00",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "69,600.00",
            "TOWER 3 [Q]": "66,000.00",
            "TOWER 4 [R]": "63,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-U",
          "item_code": "U",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set W",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set W",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3844
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-V",
          "item_code": "V",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set X",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set X",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3846
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/70-W",
          "item_code": "W",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; single leaf"
          ],
          "own_description": "Hardware set Y",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; single leaf — Hardware set Y",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 4800,
          "amount_state": "number",
          "printed_page": "2/H/14",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3848
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "1,200.00",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/71",
      "section": "IRONMONGERY",
      "sheet": "2 - Main",
      "source_collection_aed": 195800,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/71-A",
          "item_code": "A",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; double leaf"
          ],
          "own_description": "Hardware set B",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; double leaf — Hardware set B",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3861
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "45,600.00",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "2,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-B",
          "item_code": "B",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; double leaf"
          ],
          "own_description": "Hardware set C",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; double leaf — Hardware set C",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3863
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "12,000.00",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-C",
          "item_code": "C",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; double leaf"
          ],
          "own_description": "Hardware set F",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; double leaf — Hardware set F",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 16800,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3865
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "4,800.00",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-D",
          "item_code": "D",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel doors; double leaf"
          ],
          "own_description": "Hardware set S",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel doors; double leaf — Hardware set S",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 4800,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-E",
          "item_code": "E",
          "section": "IRONMONGERY",
          "heading_path": [
            "Steel folding doors; four leaf"
          ],
          "own_description": "Hardware set Q",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Steel folding doors; four leaf — Hardware set Q",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3871
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-F",
          "item_code": "F",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type A1",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type A1",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 2600,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3875
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-G",
          "item_code": "G",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type B",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type B",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 11700,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3877
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,300.00",
            "TOWER 1 [O]": "2,600.00",
            "TOWER 2 [P]": "2,600.00",
            "TOWER 3 [Q]": "2,600.00",
            "TOWER 4 [R]": "2,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-H",
          "item_code": "H",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type B2",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type B2",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3879
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-J",
          "item_code": "J",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type D",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type D",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 27300,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3881
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,500.00",
            "TOWER 1 [O]": "6,500.00",
            "TOWER 2 [P]": "6,500.00",
            "TOWER 3 [Q]": "3,900.00",
            "TOWER 4 [R]": "3,900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-K",
          "item_code": "K",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type D1",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type D1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3883
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-L",
          "item_code": "L",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type G",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type G",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3885
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,600.00",
            "TOWER 2 [P]": "2,600.00",
            "TOWER 3 [Q]": "2,600.00",
            "TOWER 4 [R]": "2,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-M",
          "item_code": "M",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type H",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type H",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3887
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-N",
          "item_code": "N",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type U",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type U",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 5200,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3889
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,300.00",
            "TOWER 2 [P]": "1,300.00",
            "TOWER 3 [Q]": "1,300.00",
            "TOWER 4 [R]": "1,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/71-P",
          "item_code": "P",
          "section": "IRONMONGERY",
          "heading_path": [
            "Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hardware set type X",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — IRONMONGERY — Ironmongery set; external doors; including fixing, accessories and all ancillary works as necessary — Hardware set type X",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/H/15",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3891
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/72",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/72-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Doors and Windows in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION H - DOORS AND WINDOWS (2/H) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Doors and Windows in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/H/16",
          "bill_ref": "2",
          "section_ref": "2/H",
          "source": {
            "sheet": "2 - Main",
            "row": 3916
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/73",
      "section": "BACKGROUNDS",
      "sheet": "2 - Main",
      "source_collection_aed": 37474583.232,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/73-A",
          "item_code": "A",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Lightweight concrete screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm thick (minimum); to roof",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Lightweight concrete screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — 50mm thick (minimum); to roof",
          "quantity": 3537,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 530550,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4032
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "888",
            "Tower 2 [F]": "890",
            "Tower 3 [G]": "872",
            "Tower 4 [H]": "887",
            "TOTAL QTY [I]": "3,537",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "133,200.00",
            "TOWER 2 [P]": "133,500.00",
            "TOWER 3 [Q]": "130,800.00",
            "TOWER 4 [R]": "133,050.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-B",
          "item_code": "B",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SCR-101; 100mm thick; to receive epoxy",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Type SCR-101; 100mm thick; to receive epoxy",
          "quantity": 18648,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 895104,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4036
          },
          "extra_columns": {
            "Basement [C]": "2,273",
            "GF & Podium [D]": "5,079",
            "Tower 1 [E]": "2,569",
            "Tower 2 [F]": "3,103",
            "Tower 3 [G]": "2,931",
            "Tower 4 [H]": "2,693",
            "TOTAL QTY [I]": "18,648",
            "BASEMENTS [M]": "109,104.00",
            "GF & PODIUM [N]": "243,792.00",
            "TOWER 1 [O]": "123,312.00",
            "TOWER 2 [P]": "148,944.00",
            "TOWER 3 [Q]": "140,688.00",
            "TOWER 4 [R]": "129,264.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-C",
          "item_code": "C",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SCR-101; 100mm thick; to receive carpet",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Type SCR-101; 100mm thick; to receive carpet",
          "quantity": 37,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 1776,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4038
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,776.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-D",
          "item_code": "D",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SCR-101; not exceeding 100mm thick; to receive tiles",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Type SCR-101; not exceeding 100mm thick; to receive tiles",
          "quantity": 1634,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 78432,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4040
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "745",
            "Tower 1 [E]": "148",
            "Tower 2 [F]": "168",
            "Tower 3 [G]": "159",
            "Tower 4 [H]": "414",
            "TOTAL QTY [I]": "1,634",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,760.00",
            "TOWER 1 [O]": "7,104.00",
            "TOWER 2 [P]": "8,064.00",
            "TOWER 3 [Q]": "7,632.00",
            "TOWER 4 [R]": "19,872.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-E",
          "item_code": "E",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SCR-101; not exceeding 100mm thick; to receive stones",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Type SCR-101; not exceeding 100mm thick; to receive stones",
          "quantity": 1011,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 48528,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4042
          },
          "extra_columns": {
            "Basement [C]": "1,011",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,011",
            "BASEMENTS [M]": "48,528.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-F",
          "item_code": "F",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive marble",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive marble",
          "quantity": 163576.44900000002,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 7851669.552000001,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4044
          },
          "extra_columns": {
            "Basement [C]": "383",
            "GF & Podium [D]": "7,770",
            "Tower 1 [E]": "35,510",
            "Tower 2 [F]": "41,301",
            "Tower 3 [G]": "40,187",
            "Tower 4 [H]": "38,425",
            "TOTAL QTY [I]": "163,576",
            "BASEMENTS [M]": "18,384.00",
            "GF & PODIUM [N]": "372,960.00",
            "TOWER 1 [O]": "1,704,480.00",
            "TOWER 2 [P]": "1,982,448.00",
            "TOWER 3 [Q]": "1,928,997.55",
            "TOWER 4 [R]": "1,844,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-G",
          "item_code": "G",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive porcelain floor tile",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive porcelain floor tile",
          "quantity": 37465.16,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 1798327.6800000002,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4046
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,493",
            "Tower 1 [E]": "8,017",
            "Tower 2 [F]": "9,821",
            "Tower 3 [G]": "9,070",
            "Tower 4 [H]": "9,064",
            "TOTAL QTY [I]": "37,465",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "71,664.00",
            "TOWER 1 [O]": "384,816.00",
            "TOWER 2 [P]": "471,408.00",
            "TOWER 3 [Q]": "435,367.68",
            "TOWER 4 [R]": "435,072.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-H",
          "item_code": "H",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive stone threshold",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive stone threshold",
          "quantity": 2625,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 126000,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4048
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "143",
            "Tower 1 [E]": "542",
            "Tower 2 [F]": "657",
            "Tower 3 [G]": "652",
            "Tower 4 [H]": "615",
            "TOTAL QTY [I]": "2,625",
            "BASEMENTS [M]": "768.00",
            "GF & PODIUM [N]": "6,864.00",
            "TOWER 1 [O]": "26,016.00",
            "TOWER 2 [P]": "31,536.00",
            "TOWER 3 [Q]": "31,296.00",
            "TOWER 4 [R]": "29,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-J",
          "item_code": "J",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive rubber flooring",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive rubber flooring",
          "quantity": 355,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 17040,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "355",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "355",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-K",
          "item_code": "K",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive luxury vinyl tile",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive luxury vinyl tile",
          "quantity": 129,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 6192,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4052
          },
          "extra_columns": {
            "Basement [C]": "43",
            "GF & Podium [D]": "86",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "129",
            "BASEMENTS [M]": "2,064.00",
            "GF & PODIUM [N]": "4,128.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-L",
          "item_code": "L",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive vinyl flooring",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive vinyl flooring",
          "quantity": 61,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 2928,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4054
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,928.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-M",
          "item_code": "M",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Not exceeding 100mm thick; to receive flooring matt",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Proprietary bonded wearing / concrete topping screed; laid to slope including surface preparation, accessories and all ancillary works as necessary — Not exceeding 100mm thick; to receive flooring matt",
          "quantity": 27,
          "unit": "m2",
          "rate_aed": 48,
          "amount_aed": 1296,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,296.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-r4060",
          "item_code": "",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Powerfloating"
          ],
          "own_description": "Powerfloating",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Powerfloating — Powerfloating",
          "quantity": 69231,
          "unit": "m2",
          "rate_aed": 75,
          "amount_aed": 5192325,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4060
          },
          "extra_columns": {
            "Basement [C]": "57,293",
            "GF & Podium [D]": "11,938",
            "TOTAL QTY [I]": "69,231",
            "BASEMENTS [M]": "4,296,975.00",
            "GF & PODIUM [N]": "895,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-N",
          "item_code": "N",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PLS-151; 15mm thick; to receive paint; to slab soffit",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — Type PLS-151; 15mm thick; to receive paint; to slab soffit",
          "quantity": 94189,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 4238505,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4064
          },
          "extra_columns": {
            "Basement [C]": "53,963",
            "GF & Podium [D]": "34,293",
            "Tower 1 [E]": "1,324",
            "Tower 2 [F]": "1,687",
            "Tower 3 [G]": "1,577",
            "Tower 4 [H]": "1,345",
            "TOTAL QTY [I]": "94,189",
            "BASEMENTS [M]": "2,428,335.00",
            "GF & PODIUM [N]": "1,543,185.00",
            "TOWER 1 [O]": "59,580.00",
            "TOWER 2 [P]": "75,915.00",
            "TOWER 3 [Q]": "70,965.00",
            "TOWER 4 [R]": "60,525.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-P",
          "item_code": "P",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PLS-151; 15mm thick; to receive paint; to stairs soffit",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — Type PLS-151; 15mm thick; to receive paint; to stairs soffit",
          "quantity": 9150,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 411750,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4066
          },
          "extra_columns": {
            "Basement [C]": "630",
            "GF & Podium [D]": "1,191",
            "Tower 1 [E]": "1,657",
            "Tower 2 [F]": "1,958",
            "Tower 3 [G]": "1,890",
            "Tower 4 [H]": "1,824",
            "TOTAL QTY [I]": "9,150",
            "BASEMENTS [M]": "28,350.00",
            "GF & PODIUM [N]": "53,595.00",
            "TOWER 1 [O]": "74,565.00",
            "TOWER 2 [P]": "88,110.00",
            "TOWER 3 [Q]": "85,050.00",
            "TOWER 4 [R]": "82,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-Q",
          "item_code": "Q",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PLS-151; 15mm thick; to receive wall paint",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — Type PLS-151; 15mm thick; to receive wall paint",
          "quantity": 151523,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 6818535,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4068
          },
          "extra_columns": {
            "Basement [C]": "37,144",
            "GF & Podium [D]": "38,366",
            "Tower 1 [E]": "17,107",
            "Tower 2 [F]": "20,963",
            "Tower 3 [G]": "19,281",
            "Tower 4 [H]": "18,662",
            "TOTAL QTY [I]": "151,523",
            "BASEMENTS [M]": "1,671,480.00",
            "GF & PODIUM [N]": "1,726,470.00",
            "TOWER 1 [O]": "769,815.00",
            "TOWER 2 [P]": "943,335.00",
            "TOWER 3 [Q]": "867,645.00",
            "TOWER 4 [R]": "839,790.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-R",
          "item_code": "R",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PLS-151; 15mm thick; to receive wall tiles",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — Type PLS-151; 15mm thick; to receive wall tiles",
          "quantity": 4807,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 216315,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4070
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,251",
            "Tower 1 [E]": "808",
            "Tower 2 [F]": "959",
            "Tower 3 [G]": "903",
            "Tower 4 [H]": "886",
            "TOTAL QTY [I]": "4,807",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,295.00",
            "TOWER 1 [O]": "36,360.00",
            "TOWER 2 [P]": "43,155.00",
            "TOWER 3 [Q]": "40,635.00",
            "TOWER 4 [R]": "39,870.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/73-S",
          "item_code": "S",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm thick; to receive wall paint",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — 15mm thick; to receive wall paint",
          "quantity": 205318,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 9239310,
          "amount_state": "number",
          "printed_page": "2/J/1",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4072
          },
          "extra_columns": {
            "Basement [C]": "125",
            "GF & Podium [D]": "9,306",
            "Tower 1 [E]": "45,541",
            "Tower 2 [F]": "51,853",
            "Tower 3 [G]": "49,598",
            "Tower 4 [H]": "48,895",
            "TOTAL QTY [I]": "205,318",
            "BASEMENTS [M]": "5,625.00",
            "GF & PODIUM [N]": "418,770.00",
            "TOWER 1 [O]": "2,049,345.00",
            "TOWER 2 [P]": "2,333,385.00",
            "TOWER 3 [Q]": "2,231,910.00",
            "TOWER 4 [R]": "2,200,275.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/74",
      "section": "BACKGROUNDS",
      "sheet": "2 - Main",
      "source_collection_aed": 3658864.8200000003,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/74-A",
          "item_code": "A",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm thick; to receive stone finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — 15mm thick; to receive stone finish",
          "quantity": 19105.41,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 859743.45,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4082
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "678",
            "Tower 1 [E]": "4,315",
            "Tower 2 [F]": "4,653",
            "Tower 3 [G]": "4,920",
            "Tower 4 [H]": "4,539",
            "TOTAL QTY [I]": "19,105",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,510.00",
            "TOWER 1 [O]": "194,175.00",
            "TOWER 2 [P]": "209,385.00",
            "TOWER 3 [Q]": "221,418.45",
            "TOWER 4 [R]": "204,255.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-B",
          "item_code": "B",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm thick; to receive wood veneer finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — 15mm thick; to receive wood veneer finish",
          "quantity": 4231.58,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 190421.1,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4084
          },
          "extra_columns": {
            "Basement [C]": "154",
            "GF & Podium [D]": "314",
            "Tower 1 [E]": "858",
            "Tower 2 [F]": "1,005",
            "Tower 3 [G]": "969",
            "Tower 4 [H]": "932",
            "TOTAL QTY [I]": "4,232",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "14,130.00",
            "TOWER 1 [O]": "38,610.00",
            "TOWER 2 [P]": "45,225.00",
            "TOWER 3 [Q]": "43,586.10",
            "TOWER 4 [R]": "41,940.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-C",
          "item_code": "C",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm thick; to receive wallpaper finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — 15mm thick; to receive wallpaper finish",
          "quantity": 3357.98,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 151109.1,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4086
          },
          "extra_columns": {
            "Basement [C]": "85",
            "GF & Podium [D]": "968",
            "Tower 1 [E]": "535",
            "Tower 2 [F]": "628",
            "Tower 3 [G]": "556",
            "Tower 4 [H]": "586",
            "TOTAL QTY [I]": "3,358",
            "BASEMENTS [M]": "3,825.00",
            "GF & PODIUM [N]": "43,560.00",
            "TOWER 1 [O]": "24,075.00",
            "TOWER 2 [P]": "28,260.00",
            "TOWER 3 [Q]": "25,019.10",
            "TOWER 4 [R]": "26,370.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-D",
          "item_code": "D",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm thick; to receive tile finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — 15mm thick; to receive tile finish",
          "quantity": 1157.57,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 52090.649999999994,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4088
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "217",
            "Tower 1 [E]": "248",
            "Tower 2 [F]": "236",
            "Tower 3 [G]": "227",
            "Tower 4 [H]": "230",
            "TOTAL QTY [I]": "1,158",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,765.00",
            "TOWER 1 [O]": "11,160.00",
            "TOWER 2 [P]": "10,620.00",
            "TOWER 3 [Q]": "10,195.65",
            "TOWER 4 [R]": "10,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-E",
          "item_code": "E",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Cementitious fiber-reinforced plaster system; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PLS-101; 10 to 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Cementitious fiber-reinforced plaster system; including surface preparation, accessories and all ancillary works as necessary — Type PLS-101; 10 to 20mm thick",
          "quantity": 77,
          "unit": "m2",
          "rate_aed": 60,
          "amount_aed": 4620,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4092
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-F",
          "item_code": "F",
          "section": "BACKGROUNDS",
          "heading_path": [
            "Skim coat plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-101; 15mm thick; to receive paint; to slab soffit",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — Skim coat plaster finish; including surface preparation, accessories and all ancillary works as necessary — Type CL-101; 15mm thick; to receive paint; to slab soffit",
          "quantity": 63948.07,
          "unit": "m2",
          "rate_aed": 36,
          "amount_aed": 2302130.52,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4096
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,009",
            "Tower 1 [E]": "15,717",
            "Tower 2 [F]": "14,458",
            "Tower 3 [G]": "16,875",
            "Tower 4 [H]": "14,889",
            "TOTAL QTY [I]": "63,948",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "72,324.00",
            "TOWER 1 [O]": "565,812.00",
            "TOWER 2 [P]": "520,488.00",
            "TOWER 3 [Q]": "607,502.52",
            "TOWER 4 [R]": "536,004.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-G",
          "item_code": "G",
          "section": "BACKGROUNDS",
          "heading_path": [
            "External",
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "PLS-351; To Podium upstand",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — External — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — PLS-351; To Podium upstand",
          "quantity": 45,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 2250,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4102
          },
          "extra_columns": {
            "GF & Podium [D]": "45",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-H",
          "item_code": "H",
          "section": "BACKGROUNDS",
          "heading_path": [
            "External",
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "PLS-351; Behind Parapet walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — External — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — PLS-351; Behind Parapet walls",
          "quantity": 1911,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 95550,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4104
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "455",
            "Tower 2 [F]": "503",
            "Tower 3 [G]": "450",
            "Tower 4 [H]": "503",
            "TOTAL QTY [I]": "1,911",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "22,750.00",
            "TOWER 2 [P]": "25,150.00",
            "TOWER 3 [Q]": "22,500.00",
            "TOWER 4 [R]": "25,150.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/74-J",
          "item_code": "J",
          "section": "BACKGROUNDS",
          "heading_path": [
            "External",
            "Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "PLS-351; Ceiling soffits",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — BACKGROUNDS — External — Cement base and plaster finish; including surface preparation, accessories and all ancillary works as necessary — PLS-351; Ceiling soffits",
          "quantity": 19,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 950,
          "amount_state": "number",
          "printed_page": "2/J/2",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4106
          },
          "extra_columns": {
            "GF & Podium [D]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/75",
      "section": "FLOOR FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 131853537.53,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/75-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; various size x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; various size x 20mm thick",
          "quantity": 148450.73,
          "unit": "m2",
          "rate_aed": 788,
          "amount_aed": 116979175.24000001,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4137
          },
          "extra_columns": {
            "Basement [C]": "1,388",
            "GF & Podium [D]": "7,242",
            "Tower 1 [E]": "31,874",
            "Tower 2 [F]": "37,277",
            "Tower 3 [G]": "36,087",
            "Tower 4 [H]": "34,583",
            "TOTAL QTY [I]": "148,451",
            "BASEMENTS [M]": "1,093,744.00",
            "GF & PODIUM [N]": "5,706,696.00",
            "TOWER 1 [O]": "25,116,712.00",
            "TOWER 2 [P]": "29,374,276.00",
            "TOWER 3 [Q]": "28,436,343.24",
            "TOWER 4 [R]": "27,251,404.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-104; 600 x 600 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-104; 600 x 600 x 20mm thick",
          "quantity": 15704.83,
          "unit": "m2",
          "rate_aed": 788,
          "amount_aed": 12375406.04,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "509",
            "Tower 1 [E]": "3,538",
            "Tower 2 [F]": "3,921",
            "Tower 3 [G]": "3,997",
            "Tower 4 [H]": "3,740",
            "TOTAL QTY [I]": "15,705",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "401,092.00",
            "TOWER 1 [O]": "2,787,944.00",
            "TOWER 2 [P]": "3,089,748.00",
            "TOWER 3 [Q]": "3,149,502.04",
            "TOWER 4 [R]": "2,947,120.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-104; 100mm wide x 20mm thick; to upstand",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-104; 100mm wide x 20mm thick; to upstand",
          "quantity": 3962,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 594300,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "131",
            "Tower 1 [E]": "919",
            "Tower 2 [F]": "966",
            "Tower 3 [G]": "990",
            "Tower 4 [H]": "956",
            "TOTAL QTY [I]": "3,962",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,650.00",
            "TOWER 1 [O]": "137,850.00",
            "TOWER 2 [P]": "144,900.00",
            "TOWER 3 [Q]": "148,500.00",
            "TOWER 4 [R]": "143,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-r4143",
          "item_code": "",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-108; 1200 x 600 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-108; 1200 x 600 x 20mm thick",
          "quantity": 620,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 124000,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4143
          },
          "extra_columns": {
            "Tower 1 [E]": "162",
            "Tower 2 [F]": "148",
            "Tower 3 [G]": "162",
            "Tower 4 [H]": "148",
            "TOTAL QTY [I]": "620",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,400.00",
            "TOWER 2 [P]": "29,600.00",
            "TOWER 3 [Q]": "32,400.00",
            "TOWER 4 [R]": "29,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-111; size 400 x 400 x 8mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-111; size 400 x 400 x 8mm thick",
          "quantity": 147,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 17640,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "147",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "147",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-121; size 300 x 300 x 8mm thick; in polished finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-121; size 300 x 300 x 8mm thick; in polished finish",
          "quantity": 9,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-101; size 600 x 600 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type CT-101; size 600 x 600 x 9mm thick",
          "quantity": 3143.98,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 377277.6,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4151
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "90",
            "Tower 1 [E]": "635",
            "Tower 2 [F]": "954",
            "Tower 3 [G]": "703",
            "Tower 4 [H]": "762",
            "TOTAL QTY [I]": "3,144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,800.00",
            "TOWER 1 [O]": "76,200.00",
            "TOWER 2 [P]": "114,480.00",
            "TOWER 3 [Q]": "84,357.60",
            "TOWER 4 [R]": "91,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-102; size 600 x 600 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type CT-102; size 600 x 600 x 9mm thick",
          "quantity": 1303.37,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 156404.4,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "229",
            "Tower 2 [F]": "410",
            "Tower 3 [G]": "308",
            "Tower 4 [H]": "329",
            "TOTAL QTY [I]": "1,303",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,240.00",
            "TOWER 1 [O]": "27,480.00",
            "TOWER 2 [P]": "49,200.00",
            "TOWER 3 [Q]": "37,004.40",
            "TOWER 4 [R]": "39,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-104; size 195 x 1200 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type CT-104; size 195 x 1200 x 9mm thick",
          "quantity": 32749.81,
          "unit": "m2",
          "rate_aed": 25,
          "amount_aed": 818745.25,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,108",
            "Tower 1 [E]": "7,153",
            "Tower 2 [F]": "8,457",
            "Tower 3 [G]": "8,059",
            "Tower 4 [H]": "7,973",
            "TOTAL QTY [I]": "32,750",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,700.00",
            "TOWER 1 [O]": "178,825.00",
            "TOWER 2 [P]": "211,425.00",
            "TOWER 3 [Q]": "201,470.25",
            "TOWER 4 [R]": "199,325.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-105; size 600 x 600 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type CT-105; size 600 x 600 x 9mm thick",
          "quantity": 268,
          "unit": "m2",
          "rate_aed": 203,
          "amount_aed": 54404,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "268",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "268",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "54,404.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-K",
          "item_code": "K",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Ceramic floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-151; size 200 x 200 x 10mm thick; heavy duty",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Ceramic floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-151; size 200 x 200 x 10mm thick; heavy duty",
          "quantity": 447,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 44700,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "447",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "447",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "44,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-L",
          "item_code": "L",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Ceramic floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-161; size 200 x 200 x 10mm thick; to wet areas",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Ceramic floor tile; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-161; size 200 x 200 x 10mm thick; to wet areas",
          "quantity": 1031,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 103100,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "142",
            "Tower 1 [E]": "148",
            "Tower 2 [F]": "168",
            "Tower 3 [G]": "159",
            "Tower 4 [H]": "414",
            "TOTAL QTY [I]": "1,031",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,200.00",
            "TOWER 1 [O]": "14,800.00",
            "TOWER 2 [P]": "16,800.00",
            "TOWER 3 [Q]": "15,900.00",
            "TOWER 4 [R]": "41,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-M",
          "item_code": "M",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Prefinished accessible raised floor system; with panels on concealed support system and pedestals; including adhesive, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-101; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Prefinished accessible raised floor system; with panels on concealed support system and pedestals; including adhesive, fixings, accessories and all ancillary works as necessary — Type RF-101; size 600 x 600mm",
          "quantity": 82,
          "unit": "m2",
          "rate_aed": 1851,
          "amount_aed": 151782,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "151,782.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-N",
          "item_code": "N",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Prefinished accessible raised floor system; with panels on concealed support system and pedestals; including adhesive, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-111; size 600 x 600 x 100mm high; to telecom rooms",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Prefinished accessible raised floor system; with panels on concealed support system and pedestals; including adhesive, fixings, accessories and all ancillary works as necessary — Type RF-111; size 600 x 600 x 100mm high; to telecom rooms",
          "quantity": 23,
          "unit": "m2",
          "rate_aed": 1851,
          "amount_aed": 42573,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,573.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/75-P",
          "item_code": "P",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Carpet sheet flooring; laid on cement and sand screed (measured elsewhere); including backing, adhesive, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLS-421; to prayer rooms",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Carpet sheet flooring; laid on cement and sand screed (measured elsewhere); including backing, adhesive, fixings, accessories and all ancillary works as necessary — Type FLS-421; to prayer rooms",
          "quantity": 37,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 12950,
          "amount_state": "number",
          "printed_page": "2/J/3",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/76",
      "section": "FLOOR FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 2895974.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/76-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Entrance mat; recessed aluminium profile mat and frames, slip resistant; including backing, adhesive, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLS-881; to semi enclosed areas",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Entrance mat; recessed aluminium profile mat and frames, slip resistant; including backing, adhesive, fixings, accessories and all ancillary works as necessary — Type FLS-881; to semi enclosed areas",
          "quantity": 83,
          "unit": "m2",
          "rate_aed": 1620,
          "amount_aed": 134460,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4185
          },
          "extra_columns": {
            "Basement [C]": "47",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "76,140.00",
            "GF & PODIUM [N]": "58,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-281; 150mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-281; 150mm wide",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 750,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-281; 200mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-281; 200mm wide",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-281; 250mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-281; 250mm wide",
          "quantity": 3,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 750,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-r4195",
          "item_code": "",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-281; to varying widths",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stone threshold; in polished granite; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type FLH-281; to varying widths",
          "quantity": 494,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 148200,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4195
          },
          "extra_columns": {
            "Basement [C]": "19",
            "GF & Podium [D]": "53",
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "116",
            "Tower 3 [G]": "106",
            "Tower 4 [H]": "102",
            "TOTAL QTY [I]": "494",
            "BASEMENTS [M]": "5,700.00",
            "GF & PODIUM [N]": "15,900.00",
            "TOWER 1 [O]": "29,400.00",
            "TOWER 2 [P]": "34,800.00",
            "TOWER 3 [Q]": "31,800.00",
            "TOWER 4 [R]": "30,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 100 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 100 x 20mm thick",
          "quantity": 8521.85,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 852185,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "275",
            "Tower 1 [E]": "1,903",
            "Tower 2 [F]": "2,176",
            "Tower 3 [G]": "2,144",
            "Tower 4 [H]": "2,024",
            "TOTAL QTY [I]": "8,522",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,500.00",
            "TOWER 1 [O]": "190,300.00",
            "TOWER 2 [P]": "217,600.00",
            "TOWER 3 [Q]": "214,385.00",
            "TOWER 4 [R]": "202,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 150 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 150 x 20mm thick",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "300.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 200 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 200 x 20mm thick",
          "quantity": 1094.2,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 218840,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "117",
            "Tower 1 [E]": "304",
            "Tower 2 [F]": "248",
            "Tower 3 [G]": "209",
            "Tower 4 [H]": "216",
            "TOTAL QTY [I]": "1,094",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,400.00",
            "TOWER 1 [O]": "60,800.00",
            "TOWER 2 [P]": "49,600.00",
            "TOWER 3 [Q]": "41,840.00",
            "TOWER 4 [R]": "43,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 250 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 250 x 20mm thick",
          "quantity": 1199.5,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 299875,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "67",
            "Tower 1 [E]": "258",
            "Tower 2 [F]": "286",
            "Tower 3 [G]": "304",
            "Tower 4 [H]": "285",
            "TOTAL QTY [I]": "1,200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,750.00",
            "TOWER 1 [O]": "64,500.00",
            "TOWER 2 [P]": "71,500.00",
            "TOWER 3 [Q]": "75,875.00",
            "TOWER 4 [R]": "71,250.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 300 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 300 x 20mm thick",
          "quantity": 1599.8,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 479940,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4207
          },
          "extra_columns": {
            "Basement [C]": "53",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "333",
            "Tower 2 [F]": "386",
            "Tower 3 [G]": "371",
            "Tower 4 [H]": "357",
            "TOTAL QTY [I]": "1,600",
            "BASEMENTS [M]": "15,900.00",
            "GF & PODIUM [N]": "30,000.00",
            "TOWER 1 [O]": "99,900.00",
            "TOWER 2 [P]": "115,800.00",
            "TOWER 3 [Q]": "111,240.00",
            "TOWER 4 [R]": "107,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-K",
          "item_code": "K",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 350 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 350 x 20mm thick",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 350,
          "amount_aed": 4550,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,550.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-L",
          "item_code": "L",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 400 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 400 x 20mm thick",
          "quantity": 190.87,
          "unit": "m",
          "rate_aed": 400,
          "amount_aed": 76348,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "59",
            "Tower 3 [G]": "67",
            "Tower 4 [H]": "61",
            "TOTAL QTY [I]": "191",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,600.00",
            "TOWER 3 [Q]": "26,748.00",
            "TOWER 4 [R]": "24,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-M",
          "item_code": "M",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 450 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 450 x 20mm thick",
          "quantity": 1450.57,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 652756.5,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "281",
            "Tower 2 [F]": "382",
            "Tower 3 [G]": "385",
            "Tower 4 [H]": "355",
            "TOTAL QTY [I]": "1,451",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,600.00",
            "TOWER 1 [O]": "126,450.00",
            "TOWER 2 [P]": "171,900.00",
            "TOWER 3 [Q]": "173,056.50",
            "TOWER 4 [R]": "159,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-N",
          "item_code": "N",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-105; 135 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-105; 135 x 20mm thick",
          "quantity": 144,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 18720,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,850.00",
            "TOWER 3 [Q]": "6,760.00",
            "TOWER 4 [R]": "5,980.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/76-P",
          "item_code": "P",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-105; 150 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Marble threshold; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-105; 150 x 20mm thick",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 150,
          "amount_state": "number",
          "printed_page": "2/J/4",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/77",
      "section": "FLOOR FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 1057887,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/77-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-107; 100 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-107; 100 x 20mm thick",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 2200,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-107; 150 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-107; 150 x 20mm thick",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-107; 200 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-107; 200 x 20mm thick",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-107; 250 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Reconstituted stone; laid on cement and sand screed (measured separately); including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-107; 250 x 20mm thick",
          "quantity": 4,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "White aggregate concrete tile; laid to slope on lightweight concrete (measured elsewhere); including proprietary underlay pads, adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 400 x 400 x 40mm thick; to roof",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — White aggregate concrete tile; laid to slope on lightweight concrete (measured elsewhere); including proprietary underlay pads, adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Size 400 x 400 x 40mm thick; to roof",
          "quantity": 3537,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 707400,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "888",
            "Tower 2 [F]": "890",
            "Tower 3 [G]": "872",
            "Tower 4 [H]": "887",
            "TOTAL QTY [I]": "3,537",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "177,600.00",
            "TOWER 2 [P]": "178,000.00",
            "TOWER 3 [Q]": "174,400.00",
            "TOWER 4 [R]": "177,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Rubber flooring; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-101; 8mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Rubber flooring; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type RF-101; 8mm thick",
          "quantity": 355,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 230750,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "355",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "355",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "230,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Luxury vinyl tile; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-102; size 230 x 1220 x 5mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Luxury vinyl tile; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type RF-102; size 230 x 1220 x 5mm thick",
          "quantity": 129,
          "unit": "m2",
          "rate_aed": 408,
          "amount_aed": 52632,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4254
          },
          "extra_columns": {
            "Basement [C]": "43",
            "GF & Podium [D]": "86",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "129",
            "BASEMENTS [M]": "17,544.00",
            "GF & PODIUM [N]": "35,088.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Vinyl flooring; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-103; 2mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Vinyl flooring; laid on cement and sand screed (measured elsewhere); including adhesive, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type RF-103; 2mm thick",
          "quantity": 61,
          "unit": "m2",
          "rate_aed": 265,
          "amount_aed": 16165,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4258
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,165.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/77-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Entrance lobby flooring matt; laid on cement and sand screed (measured elsewhere); including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type RF-104; 17mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Entrance lobby flooring matt; laid on cement and sand screed (measured elsewhere); including accessories and all ancillary works as necessary — Type RF-104; 17mm thick",
          "quantity": 27,
          "unit": "m2",
          "rate_aed": 1620,
          "amount_aed": 43740,
          "amount_state": "number",
          "printed_page": "2/J/5",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4262
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,740.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/78",
      "section": "FLOOR FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 16486093.08,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/78-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type S1b; 80mm high; 400mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary — Type S1b; 80mm high; 400mm wide",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 103,
          "amount_aed": 10403,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "101",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,403.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-103; size 600 x 100 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary — Type CT-103; size 600 x 100 x 9mm thick",
          "quantity": 7766,
          "unit": "m",
          "rate_aed": 103,
          "amount_aed": 799898,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4280
          },
          "extra_columns": {
            "GF & Podium [D]": "217",
            "Tower 1 [E]": "1,792",
            "Tower 2 [F]": "2,135",
            "Tower 3 [G]": "1,769",
            "Tower 4 [H]": "1,853",
            "TOTAL QTY [I]": "7,766",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,351.00",
            "TOWER 1 [O]": "184,576.00",
            "TOWER 2 [P]": "219,905.00",
            "TOWER 3 [Q]": "182,207.00",
            "TOWER 4 [R]": "190,859.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-104; size 600 x 100 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary — Type CT-104; size 600 x 100 x 9mm thick",
          "quantity": 8409.36,
          "unit": "m",
          "rate_aed": 103,
          "amount_aed": 866164.0800000001,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4282
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "258",
            "Tower 1 [E]": "1,792",
            "Tower 2 [F]": "2,295",
            "Tower 3 [G]": "2,047",
            "Tower 4 [H]": "2,017",
            "TOTAL QTY [I]": "8,409",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,574.00",
            "TOWER 1 [O]": "184,576.00",
            "TOWER 2 [P]": "236,385.00",
            "TOWER 3 [Q]": "210,878.08",
            "TOWER 4 [R]": "207,751.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-107; size 600 x 100 x 9mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Porcelain tile skirting; including adhesive, accessories and all ancillary works as necessary — Type CT-107; size 600 x 100 x 9mm thick",
          "quantity": 137,
          "unit": "m",
          "rate_aed": 103,
          "amount_aed": 14111,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "137",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "137",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,111.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Ceramic tile skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type S2b; 80mm high; 200mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Ceramic tile skirting; including adhesive, accessories and all ancillary works as necessary — Type S2b; 80mm high; 200mm wide",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3515,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,515.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stone skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-103; size 600 x 100 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stone skirting; including adhesive, accessories and all ancillary works as necessary — Type ST-103; size 600 x 100 x 20mm thick",
          "quantity": 98218,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 14732700,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4292
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4,098",
            "Tower 1 [E]": "22,237",
            "Tower 2 [F]": "25,536",
            "Tower 3 [G]": "24,833",
            "Tower 4 [H]": "21,514",
            "TOTAL QTY [I]": "98,218",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "614,700.00",
            "TOWER 1 [O]": "3,335,550.00",
            "TOWER 2 [P]": "3,830,400.00",
            "TOWER 3 [Q]": "3,724,950.00",
            "TOWER 4 [R]": "3,227,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Timber skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type S3b; 80mm high; 20mm thick solid ash hardwood",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Timber skirting; including adhesive, accessories and all ancillary works as necessary — Type S3b; 80mm high; 20mm thick solid ash hardwood",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 21150,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "141",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stainless steel skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-106; 100mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Stainless steel skirting; including adhesive, accessories and all ancillary works as necessary — Type MT-106; 100mm high",
          "quantity": 136,
          "unit": "m",
          "rate_aed": 202,
          "amount_aed": 27472,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4300
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "59",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "33",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,444.00",
            "TOWER 2 [P]": "11,918.00",
            "TOWER 3 [Q]": "4,444.00",
            "TOWER 4 [R]": "6,666.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/78-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Metal skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-112; 60mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — FLOOR FINISHES — Metal skirting; including adhesive, accessories and all ancillary works as necessary — Type MT-112; 60mm high",
          "quantity": 89,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 10680,
          "amount_state": "number",
          "printed_page": "2/J/6",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "89",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "89",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/79",
      "section": "WALL FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 19878765.68,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/79-A",
          "item_code": "A",
          "section": "WALL FINISHES",
          "heading_path": [
            "Ceramic wall tile; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary"
          ],
          "own_description": "Type LIN-681; size 200 x 200 x 6mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Ceramic wall tile; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary — Type LIN-681; size 200 x 200 x 6mm thick",
          "quantity": 848,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 84800,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "848",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "848",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "84,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-B",
          "item_code": "B",
          "section": "WALL FINISHES",
          "heading_path": [
            "Ceramic wall tile; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary"
          ],
          "own_description": "Type LIN-682; size 200 x 300 x 6mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Ceramic wall tile; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary — Type LIN-682; size 200 x 300 x 6mm thick",
          "quantity": 3959,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 395900,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4332
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "403",
            "Tower 1 [E]": "808",
            "Tower 2 [F]": "959",
            "Tower 3 [G]": "903",
            "Tower 4 [H]": "886",
            "TOTAL QTY [I]": "3,959",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,300.00",
            "TOWER 1 [O]": "80,800.00",
            "TOWER 2 [P]": "95,900.00",
            "TOWER 3 [Q]": "90,300.00",
            "TOWER 4 [R]": "88,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-C",
          "item_code": "C",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-102; size 600 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-102; size 600 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "quantity": 955.5699999999999,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 114668.4,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "248",
            "Tower 2 [F]": "236",
            "Tower 3 [G]": "227",
            "Tower 4 [H]": "230",
            "TOTAL QTY [I]": "956",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "29,760.00",
            "TOWER 2 [P]": "28,320.00",
            "TOWER 3 [Q]": "27,188.40",
            "TOWER 4 [R]": "27,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-D",
          "item_code": "D",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-102; size 600 x 600 x 9mm thick; fixed on plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-102; size 600 x 600 x 9mm thick; fixed on plaster board",
          "quantity": 1036.3,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 124356,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4338
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "173",
            "Tower 2 [F]": "382",
            "Tower 3 [G]": "213",
            "Tower 4 [H]": "239",
            "TOTAL QTY [I]": "1,036",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,480.00",
            "TOWER 1 [O]": "20,760.00",
            "TOWER 2 [P]": "45,840.00",
            "TOWER 3 [Q]": "25,596.00",
            "TOWER 4 [R]": "28,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-E",
          "item_code": "E",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-106; size 600 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-106; size 600 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "quantity": 136,
          "unit": "m2",
          "rate_aed": 203,
          "amount_aed": 27608,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4340
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "136",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,608.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-F",
          "item_code": "F",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-106; size 600 x 600 x 9mm thick; fixed on plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-106; size 600 x 600 x 9mm thick; fixed on plaster board",
          "quantity": 354,
          "unit": "m2",
          "rate_aed": 203,
          "amount_aed": 71862,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4342
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "354",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "354",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "71,862.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-G",
          "item_code": "G",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-108; size 300 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-108; size 300 x 600 x 9mm thick; render on cement sand plaster (measured separately)",
          "quantity": 65,
          "unit": "m2",
          "rate_aed": 225,
          "amount_aed": 14625,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "65",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-H",
          "item_code": "H",
          "section": "WALL FINISHES",
          "heading_path": [
            "Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CT-108; size 300 x 600 x 9mm thick; fixed on plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Porcelain wall tile; including grouting, joints, dry set mortar or adhesive, edge trim, accessories and all ancillary works as necessary — Type CT-108; size 300 x 600 x 9mm thick; fixed on plaster board",
          "quantity": 49,
          "unit": "m2",
          "rate_aed": 225,
          "amount_aed": 11025,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "49",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,025.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-J",
          "item_code": "J",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary"
          ],
          "own_description": "Type ST-101; 12mm thick; to backsplash",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary — Type ST-101; 12mm thick; to backsplash",
          "quantity": 5367.73,
          "unit": "m2",
          "rate_aed": 824,
          "amount_aed": 4423009.52,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "207",
            "Tower 1 [E]": "1,206",
            "Tower 2 [F]": "1,297",
            "Tower 3 [G]": "1,393",
            "Tower 4 [H]": "1,265",
            "TOTAL QTY [I]": "5,368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "170,568.00",
            "TOWER 1 [O]": "993,744.00",
            "TOWER 2 [P]": "1,068,728.00",
            "TOWER 3 [Q]": "1,147,609.52",
            "TOWER 4 [R]": "1,042,360.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-K",
          "item_code": "K",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; size 600 x 600 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; render on cement sand plaster (measured separately); including grouting, joints, dry set mortar or adhesive and all ancillary works as necessary — Type ST-102; size 600 x 600 x 20mm thick",
          "quantity": 13737.68,
          "unit": "m2",
          "rate_aed": 480,
          "amount_aed": 6594086.4,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4352
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "471",
            "Tower 1 [E]": "3,109",
            "Tower 2 [F]": "3,356",
            "Tower 3 [G]": "3,528",
            "Tower 4 [H]": "3,274",
            "TOTAL QTY [I]": "13,738",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "226,080.00",
            "TOWER 1 [O]": "1,492,320.00",
            "TOWER 2 [P]": "1,610,880.00",
            "TOWER 3 [Q]": "1,693,286.40",
            "TOWER 4 [R]": "1,571,520.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-L",
          "item_code": "L",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-101; 12mm thick; to backsplash",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary — Type ST-101; 12mm thick; to backsplash",
          "quantity": 1465.58,
          "unit": "m2",
          "rate_aed": 824,
          "amount_aed": 1207637.92,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4356
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "352",
            "Tower 2 [F]": "378",
            "Tower 3 [G]": "346",
            "Tower 4 [H]": "339",
            "TOTAL QTY [I]": "1,466",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,024.00",
            "TOWER 1 [O]": "290,048.00",
            "TOWER 2 [P]": "311,472.00",
            "TOWER 3 [Q]": "284,757.92",
            "TOWER 4 [R]": "279,336.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-M",
          "item_code": "M",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-101; 12mm thick; to sidesplash",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary — Type ST-101; 12mm thick; to sidesplash",
          "quantity": 629.41,
          "unit": "m2",
          "rate_aed": 824,
          "amount_aed": 518633.83999999997,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "147",
            "Tower 2 [F]": "152",
            "Tower 3 [G]": "160",
            "Tower 4 [H]": "148",
            "TOTAL QTY [I]": "629",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,128.00",
            "TOWER 1 [O]": "121,128.00",
            "TOWER 2 [P]": "125,248.00",
            "TOWER 3 [Q]": "132,177.84",
            "TOWER 4 [R]": "121,952.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-N",
          "item_code": "N",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-101; 100mm high; 12mm thick; to sidesplash",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary — Type ST-101; 100mm high; 12mm thick; to sidesplash",
          "quantity": 4,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "150.00",
            "TOWER 2 [P]": "150.00",
            "TOWER 3 [Q]": "150.00",
            "TOWER 4 [R]": "150.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/79-P",
          "item_code": "P",
          "section": "WALL FINISHES",
          "heading_path": [
            "Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; size 600 x 600 x 20mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Stone finish; fixed on plaster board; including adhesive, accessories and all ancillary works as necessary — Type ST-102; size 600 x 600 x 20mm thick",
          "quantity": 13104.07,
          "unit": "m2",
          "rate_aed": 480,
          "amount_aed": 6289953.6,
          "amount_state": "number",
          "printed_page": "2/J/7",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "394",
            "Tower 1 [E]": "2,941",
            "Tower 2 [F]": "3,275",
            "Tower 3 [G]": "3,359",
            "Tower 4 [H]": "3,135",
            "TOTAL QTY [I]": "13,104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "189,120.00",
            "TOWER 1 [O]": "1,411,680.00",
            "TOWER 2 [P]": "1,572,000.00",
            "TOWER 3 [Q]": "1,612,353.60",
            "TOWER 4 [R]": "1,504,800.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/80",
      "section": "WALL FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 15269702.059999999,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/80-A",
          "item_code": "A",
          "section": "WALL FINISHES",
          "heading_path": [
            "Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-109; to lift doors",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type MT-109; to lift doors",
          "quantity": 3803.26,
          "unit": "m2",
          "rate_aed": 1200,
          "amount_aed": 4563912,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4377
          },
          "extra_columns": {
            "Basement [C]": "133",
            "GF & Podium [D]": "266",
            "Tower 1 [E]": "787",
            "Tower 2 [F]": "909",
            "Tower 3 [G]": "865",
            "Tower 4 [H]": "843",
            "TOTAL QTY [I]": "3,803",
            "BASEMENTS [M]": "159,600.00",
            "GF & PODIUM [N]": "319,200.00",
            "TOWER 1 [O]": "944,400.00",
            "TOWER 2 [P]": "1,090,800.00",
            "TOWER 3 [Q]": "1,038,312.00",
            "TOWER 4 [R]": "1,011,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-B",
          "item_code": "B",
          "section": "WALL FINISHES",
          "heading_path": [
            "Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-109; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type MT-109; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "quantity": 3937.46,
          "unit": "m2",
          "rate_aed": 1200,
          "amount_aed": 4724952,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4379
          },
          "extra_columns": {
            "Basement [C]": "148",
            "GF & Podium [D]": "298",
            "Tower 1 [E]": "804",
            "Tower 2 [F]": "942",
            "Tower 3 [G]": "907",
            "Tower 4 [H]": "838",
            "TOTAL QTY [I]": "3,937",
            "BASEMENTS [M]": "177,600.00",
            "GF & PODIUM [N]": "357,600.00",
            "TOWER 1 [O]": "964,800.00",
            "TOWER 2 [P]": "1,130,400.00",
            "TOWER 3 [Q]": "1,088,952.00",
            "TOWER 4 [R]": "1,005,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-C",
          "item_code": "C",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-101; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WD-101; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "quantity": 32,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 20800,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "8",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,200.00",
            "TOWER 2 [P]": "5,200.00",
            "TOWER 3 [Q]": "5,200.00",
            "TOWER 4 [R]": "5,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-D",
          "item_code": "D",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; fixed on plaster board/plywood",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WD-102; fixed on plaster board/plywood",
          "quantity": 465,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 302250,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4385
          },
          "extra_columns": {
            "Basement [C]": "66",
            "GF & Podium [D]": "399",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "465",
            "BASEMENTS [M]": "42,900.00",
            "GF & PODIUM [N]": "259,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-E",
          "item_code": "E",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WD-102; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "quantity": 4199.45,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 2729642.5,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4387
          },
          "extra_columns": {
            "Basement [C]": "154",
            "GF & Podium [D]": "314",
            "Tower 1 [E]": "850",
            "Tower 2 [F]": "997",
            "Tower 3 [G]": "960",
            "Tower 4 [H]": "924",
            "TOTAL QTY [I]": "4,199",
            "BASEMENTS [M]": "100,100.00",
            "GF & PODIUM [N]": "204,100.00",
            "TOWER 1 [O]": "552,500.00",
            "TOWER 2 [P]": "648,050.00",
            "TOWER 3 [Q]": "624,292.50",
            "TOWER 4 [R]": "600,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-F",
          "item_code": "F",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; fascia panel above doors; with cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WD-102; fascia panel above doors; with cement base and plaster finish (measured separately)",
          "quantity": 2642.8379999999997,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 1717844.6999999997,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "93",
            "Tower 1 [E]": "613",
            "Tower 2 [F]": "641",
            "Tower 3 [G]": "660",
            "Tower 4 [H]": "636",
            "TOTAL QTY [I]": "2,643",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60,188.70",
            "TOWER 1 [O]": "398,626.80",
            "TOWER 2 [P]": "416,387.40",
            "TOWER 3 [Q]": "429,214.50",
            "TOWER 4 [R]": "413,427.30",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-G",
          "item_code": "G",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; to entrance lobby ceilings",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wood veneer finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WD-102; to entrance lobby ceilings",
          "quantity": 16,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4391
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-H",
          "item_code": "H",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-101; fixed on plaster board/plywood",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-101; fixed on plaster board/plywood",
          "quantity": 640,
          "unit": "m2",
          "rate_aed": 307,
          "amount_aed": 196480,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "638",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "640",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "195,866.00",
            "TOWER 1 [O]": "614.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-J",
          "item_code": "J",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-101; fixed on cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-101; fixed on cement base and plaster finish (measured separately)",
          "quantity": 687,
          "unit": "m2",
          "rate_aed": 307,
          "amount_aed": 210909,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4397
          },
          "extra_columns": {
            "Basement [C]": "21",
            "GF & Podium [D]": "554",
            "Tower 1 [E]": "42",
            "Tower 2 [F]": "35",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "35",
            "TOTAL QTY [I]": "687",
            "BASEMENTS [M]": "6,447.00",
            "GF & PODIUM [N]": "170,078.00",
            "TOWER 1 [O]": "12,894.00",
            "TOWER 2 [P]": "10,745.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,745.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-K",
          "item_code": "K",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-101; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-101; fixed on plaster board/plywood frame; with cement base and plaster finish (measured separately)",
          "quantity": 2435.98,
          "unit": "m2",
          "rate_aed": 307,
          "amount_aed": 747845.86,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4399
          },
          "extra_columns": {
            "Basement [C]": "64",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "493",
            "Tower 2 [F]": "593",
            "Tower 3 [G]": "556",
            "Tower 4 [H]": "551",
            "TOTAL QTY [I]": "2,436",
            "BASEMENTS [M]": "19,648.00",
            "GF & PODIUM [N]": "54,953.00",
            "TOWER 1 [O]": "151,351.00",
            "TOWER 2 [P]": "182,051.00",
            "TOWER 3 [Q]": "170,685.86",
            "TOWER 4 [R]": "169,157.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-r4401",
          "item_code": "",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-102; fixed on cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-102; fixed on cement base and plaster finish (measured separately)",
          "quantity": 14,
          "unit": "m2",
          "rate_aed": 307,
          "amount_aed": 4298,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4401
          },
          "extra_columns": {
            "GF & Podium [D]": "14",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,298.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-L",
          "item_code": "L",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-103; fixed on plaster board/plywood",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-103; fixed on plaster board/plywood",
          "quantity": 16,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 1712,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,712.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-M",
          "item_code": "M",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-103; fixed on cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-103; fixed on cement base and plaster finish (measured separately)",
          "quantity": 6,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 642,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "642.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/80-N",
          "item_code": "N",
          "section": "WALL FINISHES",
          "heading_path": [
            "Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WF-104; fixed on cement base and plaster finish (measured separately)",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — WALL FINISHES — Wallpaper finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type WF-104; fixed on cement base and plaster finish (measured separately)",
          "quantity": 229,
          "unit": "m2",
          "rate_aed": 166,
          "amount_aed": 38014,
          "amount_state": "number",
          "printed_page": "2/J/8",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "229",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "229",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "38,014.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/81",
      "section": "CEILING FINISHES",
      "sheet": "2 - Main",
      "source_collection_aed": 1904158.605,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/81-A",
          "item_code": "A",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Gypsum board tile ceiling system; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CLG-201; size 600 x 600 x 12mm thick",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Gypsum board tile ceiling system; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CLG-201; size 600 x 600 x 12mm thick",
          "quantity": 323,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 48450,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4422
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "323",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "323",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-B",
          "item_code": "B",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Gypsum board tile ceiling system; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Extra over for access panel",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Gypsum board tile ceiling system; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Extra over for access panel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 1000,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4424
          },
          "extra_columns": {
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-C",
          "item_code": "C",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Concealed grid aluminium tile ceiling system; demountable, perforated aluminium tiles; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CLG-351; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Concealed grid aluminium tile ceiling system; demountable, perforated aluminium tiles; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CLG-351; size 600 x 600mm",
          "quantity": 6097,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 914550,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "595",
            "Tower 1 [E]": "1,218",
            "Tower 2 [F]": "1,388",
            "Tower 3 [G]": "1,339",
            "Tower 4 [H]": "1,557",
            "TOTAL QTY [I]": "6,097",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "89,250.00",
            "TOWER 1 [O]": "182,700.00",
            "TOWER 2 [P]": "208,200.00",
            "TOWER 3 [Q]": "200,850.00",
            "TOWER 4 [R]": "233,550.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-D",
          "item_code": "D",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Concealed grid aluminium tile ceiling system; demountable, perforated aluminium tiles; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Extra over for access panel",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Concealed grid aluminium tile ceiling system; demountable, perforated aluminium tiles; including finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Extra over for access panel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4430
          },
          "extra_columns": {
            "Tower 2 [F]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-E",
          "item_code": "E",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CLG-501",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CLG-501",
          "quantity": 1691,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 253650,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4434
          },
          "extra_columns": {
            "Basement [C]": "1,011",
            "GF & Podium [D]": "680",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,691",
            "BASEMENTS [M]": "151,650.00",
            "GF & PODIUM [N]": "102,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-F",
          "item_code": "F",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CLG-501; to A/C and non A/C spaces",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CLG-501; to A/C and non A/C spaces",
          "quantity": 3069,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 460350,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4436
          },
          "extra_columns": {
            "GF & Podium [D]": "3,069",
            "TOTAL QTY [I]": "3,069",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "460,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-G",
          "item_code": "G",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Extra over for access panel",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Extra over for access panel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4438
          },
          "extra_columns": {
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-H",
          "item_code": "H",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CLG-501; bulkheads",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CLG-501; bulkheads",
          "quantity": 807,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 121050,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4440
          },
          "extra_columns": {
            "Basement [C]": "461",
            "GF & Podium [D]": "346.00",
            "TOTAL QTY [I]": "807",
            "BASEMENTS [M]": "69,150.00",
            "GF & PODIUM [N]": "51,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-J",
          "item_code": "J",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "Type CL-106; bulkhead; 3000mm not exceeding 3500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system; 13mm thick; non-combustible board panels supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — Type CL-106; bulkhead; 3000mm not exceeding 3500mm high",
          "quantity": 104,
          "unit": "m2",
          "rate_aed": 200,
          "amount_aed": 20800,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4442
          },
          "extra_columns": {
            "GF & Podium [D]": "104.00",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/81-K",
          "item_code": "K",
          "section": "CEILING FINISHES",
          "heading_path": [
            "Calcium silicate board ceiling system reinforced ; 2 sided 13mm thick; with 100mm thick rockwool insulation supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories"
          ],
          "own_description": "To drywall above glazing to parking vestibule",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — CEILING FINISHES — Calcium silicate board ceiling system reinforced ; 2 sided 13mm thick; with 100mm thick rockwool insulation supported by metal frame system; including insulation, finishes, suspended metal support framing system, brackets, fastenings, accessories and all necessary fixings and accessories — To drywall above glazing to parking vestibule",
          "quantity": 421,
          "unit": "m",
          "rate_aed": 176.505,
          "amount_aed": 74308.605,
          "amount_state": "number",
          "printed_page": "2/J/9",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4446
          },
          "extra_columns": {
            "Basement [C]": "215",
            "GF & Podium [D]": "206.00",
            "TOTAL QTY [I]": "421",
            "BASEMENTS [M]": "37,948.57",
            "GF & PODIUM [N]": "36,360.03",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/82",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 1706965,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/82-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [
            "Staircase nosing; UPVC carrier insert filled with anti-slip black carborundum infill; including adhesive, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "20mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Staircase nosing; UPVC carrier insert filled with anti-slip black carborundum infill; including adhesive, fixings, accessories and all ancillary works as necessary — 20mm wide",
          "quantity": 12297,
          "unit": "m",
          "rate_aed": 35,
          "amount_aed": 430395,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4464
          },
          "extra_columns": {
            "Basement [C]": "930",
            "GF & Podium [D]": "1,455",
            "Tower 1 [E]": "2,189",
            "Tower 2 [F]": "2,664",
            "Tower 3 [G]": "2,546",
            "Tower 4 [H]": "2,513",
            "TOTAL QTY [I]": "12,297",
            "BASEMENTS [M]": "32,550.00",
            "GF & PODIUM [N]": "50,925.00",
            "TOWER 1 [O]": "76,615.00",
            "TOWER 2 [P]": "93,240.00",
            "TOWER 3 [Q]": "89,110.00",
            "TOWER 4 [R]": "87,955.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [
            "Movement joint; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-108; to floor finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Movement joint; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-108; to floor finish",
          "quantity": 2911.2,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 218340,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "289",
            "Tower 1 [E]": "527",
            "Tower 2 [F]": "828",
            "Tower 3 [G]": "592",
            "Tower 4 [H]": "675",
            "TOTAL QTY [I]": "2,911",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,675.00",
            "TOWER 1 [O]": "39,525.00",
            "TOWER 2 [P]": "62,100.00",
            "TOWER 3 [Q]": "44,415.00",
            "TOWER 4 [R]": "50,625.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [
            "Metal trim; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT - 105",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Metal trim; including finishes, fixings, accessories and all ancillary works as necessary — Type MT - 105",
          "quantity": 3448,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 413760,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4472
          },
          "extra_columns": {
            "Tower 2 [F]": "3,448",
            "TOTAL QTY [I]": "3,448",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "413,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [
            "Metal trim; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-110; to wall finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Metal trim; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-110; to wall finish",
          "quantity": 5032,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 603840,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4474
          },
          "extra_columns": {
            "Basement [C]": "176",
            "GF & Podium [D]": "368",
            "Tower 1 [E]": "1,023",
            "Tower 2 [F]": "1,199",
            "Tower 3 [G]": "1,155",
            "Tower 4 [H]": "1,111",
            "TOTAL QTY [I]": "5,032",
            "BASEMENTS [M]": "21,120.00",
            "GF & PODIUM [N]": "44,160.00",
            "TOWER 1 [O]": "122,760.00",
            "TOWER 2 [P]": "143,880.00",
            "TOWER 3 [Q]": "138,600.00",
            "TOWER 4 [R]": "133,320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [
            "Metal trim; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-111; to floor finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Metal trim; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-111; to floor finish",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 5040,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4476
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [
            "Metal trim; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-113; to floor finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Metal trim; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-113; to floor finish",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4478
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-G",
          "item_code": "G",
          "section": "SUNDRIES",
          "heading_path": [
            "Metal trim; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-114; to floor finish",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Metal trim; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-114; to floor finish",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 6600,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4480
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-H",
          "item_code": "H",
          "section": "SUNDRIES",
          "heading_path": [
            "Wood frame; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; size 50x50mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Wood frame; including finishes, fixings, accessories and all ancillary works as necessary — Type WD-102; size 50x50mm",
          "quantity": 153,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4484
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "153",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "153",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-J",
          "item_code": "J",
          "section": "SUNDRIES",
          "heading_path": [
            "Wood frame; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; size 300x50mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Wood frame; including finishes, fixings, accessories and all ancillary works as necessary — Type WD-102; size 300x50mm",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 140,
          "amount_aed": 14420,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4486
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/82-K",
          "item_code": "K",
          "section": "SUNDRIES",
          "heading_path": [
            "Curtain Pelmets"
          ],
          "own_description": "BOH meeting room & service provider room",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUNDRIES — Curtain Pelmets — BOH meeting room & service provider room",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/J/10",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4490
          },
          "extra_columns": {
            "GF & Podium [D]": "20.00",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/83",
      "section": "SUSPENDED CEILING",
      "sheet": "2 - Main",
      "source_collection_aed": 10253430.62,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/83-A",
          "item_code": "A",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CLG-101; ceiling drop over 200mm but not exceeding 2500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CLG-101; ceiling drop over 200mm but not exceeding 2500mm",
          "quantity": 37,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 3959,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,959.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-B",
          "item_code": "B",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 450 x 450mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 450 x 450mm",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4520
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-C",
          "item_code": "C",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop not exceeding 500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop not exceeding 500mm",
          "quantity": 5602,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 599414,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "331",
            "Tower 1 [E]": "1,208",
            "Tower 2 [F]": "1,378",
            "Tower 3 [G]": "1,396",
            "Tower 4 [H]": "1,289",
            "TOTAL QTY [I]": "5,602",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,417.00",
            "TOWER 1 [O]": "129,256.00",
            "TOWER 2 [P]": "147,446.00",
            "TOWER 3 [Q]": "149,372.00",
            "TOWER 4 [R]": "137,923.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-D",
          "item_code": "D",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 500mm but not exceeding 1000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 500mm but not exceeding 1000mm",
          "quantity": 52038.72,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 5568143.04,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,527",
            "Tower 1 [E]": "10,729",
            "Tower 2 [F]": "14,942",
            "Tower 3 [G]": "12,265",
            "Tower 4 [H]": "12,576",
            "TOTAL QTY [I]": "52,039",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "163,389.00",
            "TOWER 1 [O]": "1,148,003.00",
            "TOWER 2 [P]": "1,598,794.00",
            "TOWER 3 [Q]": "1,312,325.04",
            "TOWER 4 [R]": "1,345,632.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-E",
          "item_code": "E",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 1000mm but not exceeding 1500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 1000mm but not exceeding 1500mm",
          "quantity": 3623,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 387661,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4526
          },
          "extra_columns": {
            "Basement [C]": "186",
            "GF & Podium [D]": "997",
            "Tower 1 [E]": "330",
            "Tower 2 [F]": "1,149",
            "Tower 3 [G]": "166",
            "Tower 4 [H]": "795",
            "TOTAL QTY [I]": "3,623",
            "BASEMENTS [M]": "19,902.00",
            "GF & PODIUM [N]": "106,679.00",
            "TOWER 1 [O]": "35,310.00",
            "TOWER 2 [P]": "122,943.00",
            "TOWER 3 [Q]": "17,762.00",
            "TOWER 4 [R]": "85,065.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-F",
          "item_code": "F",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 1500mm but not exceeding 2000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 1500mm but not exceeding 2000mm",
          "quantity": 475,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 50825,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "257",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "218",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "475",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,499.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,326.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-G",
          "item_code": "G",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 2000mm but not exceeding 2500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 2000mm but not exceeding 2500mm",
          "quantity": 1026,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 109782,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "262",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "382",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "382",
            "TOTAL QTY [I]": "1,026",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,034.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "40,874.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "40,874.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-H",
          "item_code": "H",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 2500mm but not exceeding 3000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 2500mm but not exceeding 3000mm",
          "quantity": 1695,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 181365,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "755",
            "Tower 1 [E]": "266",
            "Tower 2 [F]": "166",
            "Tower 3 [G]": "235",
            "Tower 4 [H]": "273",
            "TOTAL QTY [I]": "1,695",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80,785.00",
            "TOWER 1 [O]": "28,462.00",
            "TOWER 2 [P]": "17,762.00",
            "TOWER 3 [Q]": "25,145.00",
            "TOWER 4 [R]": "29,211.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-J",
          "item_code": "J",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 3000mm but not exceeding 3500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 3000mm but not exceeding 3500mm",
          "quantity": 186,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 19902,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4534
          },
          "extra_columns": {
            "Basement [C]": "186",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "186",
            "BASEMENTS [M]": "19,902.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-K",
          "item_code": "K",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 4000mm but not exceeding 4500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 4000mm but not exceeding 4500mm",
          "quantity": 53,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 5671,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4536
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "53",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,671.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-L",
          "item_code": "L",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; ceiling drop over 5000mm but not exceeding 5500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; ceiling drop over 5000mm but not exceeding 5500mm",
          "quantity": 107,
          "unit": "m2",
          "rate_aed": 107,
          "amount_aed": 11449,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4538
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "107",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,449.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-M",
          "item_code": "M",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; not exceeding 500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; not exceeding 500mm high",
          "quantity": 32104.75,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1926285,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4540
          },
          "extra_columns": {
            "Basement [C]": "289",
            "GF & Podium [D]": "1,887",
            "Tower 1 [E]": "6,631",
            "Tower 2 [F]": "8,202",
            "Tower 3 [G]": "7,628",
            "Tower 4 [H]": "7,468",
            "TOTAL QTY [I]": "32,105",
            "BASEMENTS [M]": "17,340.00",
            "GF & PODIUM [N]": "113,220.00",
            "TOWER 1 [O]": "397,860.00",
            "TOWER 2 [P]": "492,120.00",
            "TOWER 3 [Q]": "457,665.00",
            "TOWER 4 [R]": "448,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-N",
          "item_code": "N",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; not exceeding 500mm high; curved",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; not exceeding 500mm high; curved",
          "quantity": 116,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 8700,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4542
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "93",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "116",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "6,975.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "975.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-P",
          "item_code": "P",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; 500mm not exceeding 1000mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; 500mm not exceeding 1000mm high",
          "quantity": 17917.46,
          "unit": "m2",
          "rate_aed": 73,
          "amount_aed": 1307974.5799999998,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4544
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "373",
            "Tower 1 [E]": "4,058",
            "Tower 2 [F]": "4,272",
            "Tower 3 [G]": "4,902",
            "Tower 4 [H]": "4,312",
            "TOTAL QTY [I]": "17,917",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,229.00",
            "TOWER 1 [O]": "296,234.00",
            "TOWER 2 [P]": "311,856.00",
            "TOWER 3 [Q]": "357,879.58",
            "TOWER 4 [R]": "314,776.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-Q",
          "item_code": "Q",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; 500mm not exceeding 1000mm high; curved",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; 500mm not exceeding 1000mm high; curved",
          "quantity": 51,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 5100,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "400.00",
            "TOWER 1 [O]": "4,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/83-R",
          "item_code": "R",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; 1000mm not exceeding 1500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; 1000mm not exceeding 1500mm high",
          "quantity": 448,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 67200,
          "amount_state": "number",
          "printed_page": "2/J/11",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "296",
            "Tower 1 [E]": "30",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "63",
            "TOTAL QTY [I]": "448",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "44,400.00",
            "TOWER 1 [O]": "4,500.00",
            "TOWER 2 [P]": "7,500.00",
            "TOWER 3 [Q]": "1,350.00",
            "TOWER 4 [R]": "9,450.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/84",
      "section": "SUSPENDED CEILING",
      "sheet": "2 - Main",
      "source_collection_aed": 5380804.4,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/84-A",
          "item_code": "A",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; bulkhead; 2500mm not exceeding 3000mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; bulkhead; 2500mm not exceeding 3000mm high",
          "quantity": 771,
          "unit": "m2",
          "rate_aed": 274,
          "amount_aed": 211254,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "425",
            "Tower 1 [E]": "182",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "164",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "771",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "116,450.00",
            "TOWER 1 [O]": "49,868.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "44,936.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-B",
          "item_code": "B",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; lightcove; not exceeding 500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; lightcove; not exceeding 500mm high",
          "quantity": 4545.72,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 272743.2,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4563
          },
          "extra_columns": {
            "Basement [C]": "147",
            "GF & Podium [D]": "639",
            "Tower 1 [E]": "857",
            "Tower 2 [F]": "1,004",
            "Tower 3 [G]": "968",
            "Tower 4 [H]": "931",
            "TOTAL QTY [I]": "4,546",
            "BASEMENTS [M]": "8,820.00",
            "GF & PODIUM [N]": "38,340.00",
            "TOWER 1 [O]": "51,420.00",
            "TOWER 2 [P]": "60,240.00",
            "TOWER 3 [Q]": "58,063.20",
            "TOWER 4 [R]": "55,860.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-C",
          "item_code": "C",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; lightcove; 500mm not exceeding 1000mm total girth",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; lightcove; 500mm not exceeding 1000mm total girth",
          "quantity": 961,
          "unit": "m2",
          "rate_aed": 73,
          "amount_aed": 70153,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4565
          },
          "extra_columns": {
            "Basement [C]": "147",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "54",
            "Tower 2 [F]": "460",
            "Tower 3 [G]": "54",
            "Tower 4 [H]": "246",
            "TOTAL QTY [I]": "961",
            "BASEMENTS [M]": "10,731.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,942.00",
            "TOWER 2 [P]": "33,580.00",
            "TOWER 3 [Q]": "3,942.00",
            "TOWER 4 [R]": "17,958.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-D",
          "item_code": "D",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-102; lightcove; 500mm not exceeding 1000mm total girth; curved",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-102; lightcove; 500mm not exceeding 1000mm total girth; curved",
          "quantity": 147,
          "unit": "m2",
          "rate_aed": 85,
          "amount_aed": 12495,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "81",
            "Tower 3 [G]": "11",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "147",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "935.00",
            "TOWER 2 [P]": "6,885.00",
            "TOWER 3 [Q]": "935.00",
            "TOWER 4 [R]": "3,740.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-E",
          "item_code": "E",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 400 x 400mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 400 x 400mm",
          "quantity": 1615,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 323000,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "57",
            "Tower 1 [E]": "406",
            "Tower 2 [F]": "353",
            "Tower 3 [G]": "458",
            "Tower 4 [H]": "341",
            "TOTAL QTY [I]": "1,615",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,400.00",
            "TOWER 1 [O]": "81,200.00",
            "TOWER 2 [P]": "70,600.00",
            "TOWER 3 [Q]": "91,600.00",
            "TOWER 4 [R]": "68,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-F",
          "item_code": "F",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 600 x 600mm",
          "quantity": 969,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 193800,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4571
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "70",
            "Tower 1 [E]": "192",
            "Tower 2 [F]": "260",
            "Tower 3 [G]": "215",
            "Tower 4 [H]": "224",
            "TOTAL QTY [I]": "969",
            "BASEMENTS [M]": "1,600.00",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "38,400.00",
            "TOWER 2 [P]": "52,000.00",
            "TOWER 3 [Q]": "43,000.00",
            "TOWER 4 [R]": "44,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-G",
          "item_code": "G",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CLG-121; ceiling drop over 2000mm but not exceeding 2500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CLG-121; ceiling drop over 2000mm but not exceeding 2500mm",
          "quantity": 12,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 1344,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,344.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-H",
          "item_code": "H",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CLG-121; ceiling drop over 2500mm but not exceeding 3000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CLG-121; ceiling drop over 2500mm but not exceeding 3000mm",
          "quantity": 28,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 3136,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,136.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-J",
          "item_code": "J",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 450 x 450mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 450 x 450mm",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 1000,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4579
          },
          "extra_columns": {
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-K",
          "item_code": "K",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop not exceeding 500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop not exceeding 500mm",
          "quantity": 518.23,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 58041.76,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "119",
            "Tower 2 [F]": "124",
            "Tower 3 [G]": "144",
            "Tower 4 [H]": "127",
            "TOTAL QTY [I]": "518",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "448.00",
            "TOWER 1 [O]": "13,328.00",
            "TOWER 2 [P]": "13,888.00",
            "TOWER 3 [Q]": "16,153.76",
            "TOWER 4 [R]": "14,224.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-L",
          "item_code": "L",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 500mm but not exceeding 1000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 500mm but not exceeding 1000mm",
          "quantity": 34482.12,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 3861997.4400000004,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "293",
            "Tower 1 [E]": "8,045",
            "Tower 2 [F]": "8,456",
            "Tower 3 [G]": "9,333",
            "Tower 4 [H]": "8,355",
            "TOTAL QTY [I]": "34,482",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,816.00",
            "TOWER 1 [O]": "901,040.00",
            "TOWER 2 [P]": "947,072.00",
            "TOWER 3 [Q]": "1,045,309.44",
            "TOWER 4 [R]": "935,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-M",
          "item_code": "M",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 1000mm but not exceeding 1500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 1000mm but not exceeding 1500mm",
          "quantity": 2280,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 255360,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "823",
            "Tower 1 [E]": "154",
            "Tower 2 [F]": "752",
            "Tower 3 [G]": "99",
            "Tower 4 [H]": "452",
            "TOTAL QTY [I]": "2,280",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "92,176.00",
            "TOWER 1 [O]": "17,248.00",
            "TOWER 2 [P]": "84,224.00",
            "TOWER 3 [Q]": "11,088.00",
            "TOWER 4 [R]": "50,624.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-N",
          "item_code": "N",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 1500mm but not exceeding 2000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 1500mm but not exceeding 2000mm",
          "quantity": 50,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-P",
          "item_code": "P",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 2000mm but not exceeding 2500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 2000mm but not exceeding 2500mm",
          "quantity": 46,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 5152,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "448.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,352.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,352.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-Q",
          "item_code": "Q",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 2500mm but not exceeding 3000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 2500mm but not exceeding 3000mm",
          "quantity": 782,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 87584,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "452",
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "72",
            "Tower 3 [G]": "88",
            "Tower 4 [H]": "72",
            "TOTAL QTY [I]": "782",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,624.00",
            "TOWER 1 [O]": "10,976.00",
            "TOWER 2 [P]": "8,064.00",
            "TOWER 3 [Q]": "9,856.00",
            "TOWER 4 [R]": "8,064.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/84-R",
          "item_code": "R",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; ceiling drop over 3000mm but not exceeding 3500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; ceiling drop over 3000mm but not exceeding 3500mm",
          "quantity": 162,
          "unit": "m2",
          "rate_aed": 112,
          "amount_aed": 18144,
          "amount_state": "number",
          "printed_page": "2/J/12",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "72",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "162",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,064.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/85",
      "section": "SUSPENDED CEILING",
      "sheet": "2 - Main",
      "source_collection_aed": 2317366.1,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/85-A",
          "item_code": "A",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; bulkhead; not exceeding 500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; bulkhead; not exceeding 500mm high",
          "quantity": 2752.73,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 261509.35,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "121",
            "Tower 1 [E]": "599",
            "Tower 2 [F]": "692",
            "Tower 3 [G]": "695",
            "Tower 4 [H]": "646",
            "TOTAL QTY [I]": "2,753",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,495.00",
            "TOWER 1 [O]": "56,905.00",
            "TOWER 2 [P]": "65,740.00",
            "TOWER 3 [Q]": "65,999.35",
            "TOWER 4 [R]": "61,370.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-B",
          "item_code": "B",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; bulkhead; 500mm not exceeding 1000mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; bulkhead; 500mm not exceeding 1000mm high",
          "quantity": 28,
          "unit": "m2",
          "rate_aed": 143,
          "amount_aed": 4004,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "858.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,573.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,573.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-C",
          "item_code": "C",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-103; lightcove; not exceeding 500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-103; lightcove; not exceeding 500mm high",
          "quantity": 3913.05,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 371739.75,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "132",
            "Tower 1 [E]": "886",
            "Tower 2 [F]": "963",
            "Tower 3 [G]": "1,001",
            "Tower 4 [H]": "931",
            "TOTAL QTY [I]": "3,913",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,540.00",
            "TOWER 1 [O]": "84,170.00",
            "TOWER 2 [P]": "91,485.00",
            "TOWER 3 [Q]": "95,099.75",
            "TOWER 4 [R]": "88,445.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-D",
          "item_code": "D",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 400 x 400mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 400 x 400mm",
          "quantity": 758,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 151600,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "180",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "758",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,400.00",
            "TOWER 1 [O]": "36,000.00",
            "TOWER 2 [P]": "34,000.00",
            "TOWER 3 [Q]": "40,000.00",
            "TOWER 4 [R]": "35,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-E",
          "item_code": "E",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 450 x 450mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 450 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-F",
          "item_code": "F",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Monolithic gypsum board ceiling; moisture resistant; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 600 x 600mm",
          "quantity": 4293,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 858600,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "141",
            "Tower 1 [E]": "953",
            "Tower 2 [F]": "1,088",
            "Tower 3 [G]": "1,082",
            "Tower 4 [H]": "1,029",
            "TOTAL QTY [I]": "4,293",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,200.00",
            "TOWER 1 [O]": "190,600.00",
            "TOWER 2 [P]": "217,600.00",
            "TOWER 3 [Q]": "216,400.00",
            "TOWER 4 [R]": "205,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-G",
          "item_code": "G",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Veneered wood ceiling panels; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-104; ceiling drop over 500mm but not exceeding 1000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Veneered wood ceiling panels; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-104; ceiling drop over 500mm but not exceeding 1000mm",
          "quantity": 75,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 48750,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-H",
          "item_code": "H",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Veneered wood ceiling panels; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Veneered wood ceiling panels; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 600 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4623
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-J",
          "item_code": "J",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-105; ceiling drop over 500mm but not exceeding 1000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-105; ceiling drop over 500mm but not exceeding 1000mm",
          "quantity": 100,
          "unit": "m2",
          "rate_aed": 850,
          "amount_aed": 85000,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4627
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "85,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-K",
          "item_code": "K",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 500mm but not exceeding 1000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 500mm but not exceeding 1000mm",
          "quantity": 17,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4629
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "7,650.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-L",
          "item_code": "L",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 1000mm but not exceeding 1500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 1000mm but not exceeding 1500mm",
          "quantity": 750.92,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 337914,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4631
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "174",
            "Tower 2 [F]": "180",
            "Tower 3 [G]": "202",
            "Tower 4 [H]": "184",
            "TOTAL QTY [I]": "751",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "78,300.00",
            "TOWER 2 [P]": "81,000.00",
            "TOWER 3 [Q]": "90,864.00",
            "TOWER 4 [R]": "82,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-M",
          "item_code": "M",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 1500mm but not exceeding 2000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 1500mm but not exceeding 2000mm",
          "quantity": 60,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 27000,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4633
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,800.00",
            "TOWER 1 [O]": "2,700.00",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-N",
          "item_code": "N",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 2000mm but not exceeding 2500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 2000mm but not exceeding 2500mm",
          "quantity": 13,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 5850,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4635
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-P",
          "item_code": "P",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 2500mm but not exceeding 3000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 2500mm but not exceeding 3000mm",
          "quantity": 17,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4637
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "7,650.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-Q",
          "item_code": "Q",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 3000mm but not exceeding 3500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 3000mm but not exceeding 3500mm",
          "quantity": 18,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 8100,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4639
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,600.00",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,800.00",
            "TOWER 4 [R]": "900.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-R",
          "item_code": "R",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; ceiling drop over 5500mm but not exceeding 6000mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; ceiling drop over 5500mm but not exceeding 6000mm",
          "quantity": 2,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-S",
          "item_code": "S",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; bulkhead; not exceeding 500mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; bulkhead; not exceeding 500mm high",
          "quantity": 728.6,
          "unit": "m",
          "rate_aed": 165,
          "amount_aed": 120219,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4643
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "157",
            "Tower 2 [F]": "177",
            "Tower 3 [G]": "177",
            "Tower 4 [H]": "163",
            "TOTAL QTY [I]": "729",
            "BASEMENTS [M]": "4,455.00",
            "GF & PODIUM [N]": "4,620.00",
            "TOWER 1 [O]": "25,905.00",
            "TOWER 2 [P]": "29,205.00",
            "TOWER 3 [Q]": "29,139.00",
            "TOWER 4 [R]": "26,895.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/85-T",
          "item_code": "T",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CL-106; bulkhead; 500mm not exceeding 1000mm high",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — Wood ceiling; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type CL-106; bulkhead; 500mm not exceeding 1000mm high",
          "quantity": 2,
          "unit": "m2",
          "rate_aed": 240,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/J/13",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4645
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/86",
      "section": "DECORATIONS",
      "sheet": "2 - Main",
      "source_collection_aed": 21128077.018,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/86-A",
          "item_code": "A",
          "section": "SUSPENDED CEILING",
          "heading_path": [
            "External Work",
            "Suspended ceilings; 13mm thick fiber-reinforced calcium silicate board; fixed to slab soffit with proprietary aluminium support system; including thermal insulation, fittings and all necessary fixings and accessories"
          ],
          "own_description": "To balconies and inaccessible area; drop over 150mm not exceeding 500mm",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SUSPENDED CEILING — External Work — Suspended ceilings; 13mm thick fiber-reinforced calcium silicate board; fixed to slab soffit with proprietary aluminium support system; including thermal insulation, fittings and all necessary fixings and accessories — To balconies and inaccessible area; drop over 150mm not exceeding 500mm",
          "quantity": 46503,
          "unit": "m2",
          "rate_aed": 180,
          "amount_aed": 8370540,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4659
          },
          "extra_columns": {
            "GF & Podium [D]": "2,109",
            "Tower 1 [E]": "9,882",
            "Tower 2 [F]": "12,257",
            "Tower 3 [G]": "11,106",
            "Tower 4 [H]": "11,149",
            "TOTAL QTY [I]": "46,503",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "379,620.00",
            "TOWER 1 [O]": "1,778,760.00",
            "TOWER 2 [P]": "2,206,260.00",
            "TOWER 3 [Q]": "1,999,080.00",
            "TOWER 4 [R]": "2,006,820.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-B",
          "item_code": "B",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-101 to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-101 to plastered walls",
          "quantity": 214199,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 4283980,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4665
          },
          "extra_columns": {
            "Basement [C]": "2,143",
            "GF & Podium [D]": "14,281",
            "Tower 1 [E]": "45,269",
            "Tower 2 [F]": "52,892",
            "Tower 3 [G]": "50,107",
            "Tower 4 [H]": "49,507",
            "TOTAL QTY [I]": "214,199",
            "BASEMENTS [M]": "42,860.00",
            "GF & PODIUM [N]": "285,620.00",
            "TOWER 1 [O]": "905,380.00",
            "TOWER 2 [P]": "1,057,840.00",
            "TOWER 3 [Q]": "1,002,140.00",
            "TOWER 4 [R]": "990,140.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-C",
          "item_code": "C",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-101; to plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-101; to plaster board",
          "quantity": 143897.19,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 2877943.8,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4667
          },
          "extra_columns": {
            "Basement [C]": "62",
            "GF & Podium [D]": "5,447",
            "Tower 1 [E]": "32,116",
            "Tower 2 [F]": "36,922",
            "Tower 3 [G]": "35,598",
            "Tower 4 [H]": "33,752",
            "TOTAL QTY [I]": "143,897",
            "BASEMENTS [M]": "1,240.00",
            "GF & PODIUM [N]": "108,940.00",
            "TOWER 1 [O]": "642,320.00",
            "TOWER 2 [P]": "738,440.00",
            "TOWER 3 [Q]": "711,963.80",
            "TOWER 4 [R]": "675,040.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-D",
          "item_code": "D",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-101; to slab soffits",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-101; to slab soffits",
          "quantity": 67361,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 1347220,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4669
          },
          "extra_columns": {
            "Basement [C]": "272",
            "GF & Podium [D]": "2,671",
            "Tower 1 [E]": "16,466",
            "Tower 2 [F]": "15,367",
            "Tower 3 [G]": "16,900",
            "Tower 4 [H]": "15,685",
            "TOTAL QTY [I]": "67,361",
            "BASEMENTS [M]": "5,440.00",
            "GF & PODIUM [N]": "53,420.00",
            "TOWER 1 [O]": "329,320.00",
            "TOWER 2 [P]": "307,340.00",
            "TOWER 3 [Q]": "338,000.00",
            "TOWER 4 [R]": "313,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-E",
          "item_code": "E",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-101; to suspended ceilings",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-101; to suspended ceilings",
          "quantity": 91843.90090000001,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 1836878.0180000002,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4671
          },
          "extra_columns": {
            "Basement [C]": "436",
            "GF & Podium [D]": "5,502",
            "Tower 1 [E]": "18,302",
            "Tower 2 [F]": "24,992",
            "Tower 3 [G]": "21,048",
            "Tower 4 [H]": "21,564",
            "TOTAL QTY [I]": "91,844",
            "BASEMENTS [M]": "8,720.00",
            "GF & PODIUM [N]": "110,040.00",
            "TOWER 1 [O]": "366,040.00",
            "TOWER 2 [P]": "499,840.00",
            "TOWER 3 [Q]": "420,958.02",
            "TOWER 4 [R]": "431,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-F",
          "item_code": "F",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-104; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-104; to plastered walls",
          "quantity": 126,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 2520,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4673
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "126",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "126",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-G",
          "item_code": "G",
          "section": "DECORATIONS",
          "heading_path": [
            "Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-104; to plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Washable emulsion paint; high quality acrylic copolymer-based emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-104; to plaster board",
          "quantity": 38,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 760,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4675
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-H",
          "item_code": "H",
          "section": "DECORATIONS",
          "heading_path": [
            "Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-102; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-102; to plastered walls",
          "quantity": 34633.8,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 692676,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4679
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,293",
            "Tower 1 [E]": "8,252",
            "Tower 2 [F]": "8,365",
            "Tower 3 [G]": "8,752",
            "Tower 4 [H]": "7,972",
            "TOTAL QTY [I]": "34,634",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,860.00",
            "TOWER 1 [O]": "165,040.00",
            "TOWER 2 [P]": "167,300.00",
            "TOWER 3 [Q]": "175,036.00",
            "TOWER 4 [R]": "159,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-J",
          "item_code": "J",
          "section": "DECORATIONS",
          "heading_path": [
            "Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-102; to plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-102; to plaster board",
          "quantity": 45567.72,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 911354.4,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,858",
            "Tower 1 [E]": "9,662",
            "Tower 2 [F]": "11,670",
            "Tower 3 [G]": "11,444",
            "Tower 4 [H]": "10,934",
            "TOTAL QTY [I]": "45,568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,160.00",
            "TOWER 1 [O]": "193,240.00",
            "TOWER 2 [P]": "233,400.00",
            "TOWER 3 [Q]": "228,874.40",
            "TOWER 4 [R]": "218,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-K",
          "item_code": "K",
          "section": "DECORATIONS",
          "heading_path": [
            "Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-102; to suspended ceilings",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Antibacterial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-102; to suspended ceilings",
          "quantity": 40123.44,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 802468.8,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,646",
            "Tower 1 [E]": "8,897",
            "Tower 2 [F]": "9,914",
            "Tower 3 [G]": "10,182",
            "Tower 4 [H]": "9,484",
            "TOTAL QTY [I]": "40,123",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,920.00",
            "TOWER 1 [O]": "177,940.00",
            "TOWER 2 [P]": "198,280.00",
            "TOWER 3 [Q]": "203,648.80",
            "TOWER 4 [R]": "189,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-L",
          "item_code": "L",
          "section": "DECORATIONS",
          "heading_path": [
            "PU water based acrylic lacquer paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-105; to plaster board",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — PU water based acrylic lacquer paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-105; to plaster board",
          "quantity": 16,
          "unit": "m2",
          "rate_aed": 26,
          "amount_aed": 416,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "416.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-M",
          "item_code": "M",
          "section": "DECORATIONS",
          "heading_path": [
            "Decorative paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-107; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Decorative paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-107; to plastered walls",
          "quantity": 36,
          "unit": "m2",
          "rate_aed": 24,
          "amount_aed": 864,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "864.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/86-N",
          "item_code": "N",
          "section": "DECORATIONS",
          "heading_path": [
            "Acrylic paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-107; to slab soffits",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Acrylic paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-107; to slab soffits",
          "quantity": 19,
          "unit": "m2",
          "rate_aed": 24,
          "amount_aed": 456,
          "amount_state": "number",
          "printed_page": "2/J/14",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "456.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/87",
      "section": "DECORATIONS",
      "sheet": "2 - Main",
      "source_collection_aed": 15921959.85,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/87-A",
          "item_code": "A",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-115; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-115; to plastered walls",
          "quantity": 35836,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 716720,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4707
          },
          "extra_columns": {
            "Basement [C]": "3,223",
            "GF & Podium [D]": "4,534",
            "Tower 1 [E]": "6,289",
            "Tower 2 [F]": "7,901",
            "Tower 3 [G]": "6,998",
            "Tower 4 [H]": "6,891",
            "TOTAL QTY [I]": "35,836",
            "BASEMENTS [M]": "64,460.00",
            "GF & PODIUM [N]": "90,680.00",
            "TOWER 1 [O]": "125,780.00",
            "TOWER 2 [P]": "158,020.00",
            "TOWER 3 [Q]": "139,960.00",
            "TOWER 4 [R]": "137,820.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-B",
          "item_code": "B",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-115; to slab soffits",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-115; to slab soffits",
          "quantity": 449,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 8980,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4709
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "447",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "40.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-C",
          "item_code": "C",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-115; to soffit of stairs",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-115; to soffit of stairs",
          "quantity": 9150,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 183000,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4711
          },
          "extra_columns": {
            "Basement [C]": "630",
            "GF & Podium [D]": "1,191",
            "Tower 1 [E]": "1,657",
            "Tower 2 [F]": "1,958",
            "Tower 3 [G]": "1,890",
            "Tower 4 [H]": "1,824",
            "TOTAL QTY [I]": "9,150",
            "BASEMENTS [M]": "12,600.00",
            "GF & PODIUM [N]": "23,820.00",
            "TOWER 1 [O]": "33,140.00",
            "TOWER 2 [P]": "39,160.00",
            "TOWER 3 [Q]": "37,800.00",
            "TOWER 4 [R]": "36,480.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-D",
          "item_code": "D",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-115; to walls above suspended ceilings",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-115; to walls above suspended ceilings",
          "quantity": 3900,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 78000,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4713
          },
          "extra_columns": {
            "Basement [C]": "305",
            "GF & Podium [D]": "402",
            "Tower 1 [E]": "768",
            "Tower 2 [F]": "828",
            "Tower 3 [G]": "801",
            "Tower 4 [H]": "796",
            "TOTAL QTY [I]": "3,900",
            "BASEMENTS [M]": "6,100.00",
            "GF & PODIUM [N]": "8,040.00",
            "TOWER 1 [O]": "15,360.00",
            "TOWER 2 [P]": "16,560.00",
            "TOWER 3 [Q]": "16,020.00",
            "TOWER 4 [R]": "15,920.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-E",
          "item_code": "E",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-115; to soffits above suspended ceilings",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal and anti-microbial emulsion paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-115; to soffits above suspended ceilings",
          "quantity": 34620,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 692400,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4715
          },
          "extra_columns": {
            "Basement [C]": "1,148",
            "GF & Podium [D]": "1,997",
            "Tower 1 [E]": "7,275",
            "Tower 2 [F]": "8,465",
            "Tower 3 [G]": "7,920",
            "Tower 4 [H]": "7,815",
            "TOTAL QTY [I]": "34,620",
            "BASEMENTS [M]": "22,960.00",
            "GF & PODIUM [N]": "39,940.00",
            "TOWER 1 [O]": "145,500.00",
            "TOWER 2 [P]": "169,300.00",
            "TOWER 3 [Q]": "158,400.00",
            "TOWER 4 [R]": "156,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-F",
          "item_code": "F",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-carbonation paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-151; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-carbonation paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-151; to plastered walls",
          "quantity": 50271,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 2262195,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4719
          },
          "extra_columns": {
            "Basement [C]": "29,696",
            "GF & Podium [D]": "20,575",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50,271",
            "BASEMENTS [M]": "1,336,320.00",
            "GF & PODIUM [N]": "925,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-G",
          "item_code": "G",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-carbonation paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-151; to slab soffits",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-carbonation paint; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-151; to slab soffits",
          "quantity": 83511,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 3757995,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4721
          },
          "extra_columns": {
            "Basement [C]": "53,033",
            "GF & Podium [D]": "30,478",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83,511",
            "BASEMENTS [M]": "2,386,485.00",
            "GF & PODIUM [N]": "1,371,510.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-H",
          "item_code": "H",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-121; to plastered walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-121; to plastered walls",
          "quantity": 16901.11,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 760549.9500000001,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4725
          },
          "extra_columns": {
            "Basement [C]": "1,725",
            "GF & Podium [D]": "5,498",
            "Tower 1 [E]": "1,876",
            "Tower 2 [F]": "2,151",
            "Tower 3 [G]": "3,750",
            "Tower 4 [H]": "1,901",
            "TOTAL QTY [I]": "16,901",
            "BASEMENTS [M]": "77,625.00",
            "GF & PODIUM [N]": "247,410.00",
            "TOWER 1 [O]": "84,420.00",
            "TOWER 2 [P]": "96,795.00",
            "TOWER 3 [Q]": "168,754.95",
            "TOWER 4 [R]": "85,545.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-J",
          "item_code": "J",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type PT-121; to slab soffit",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type PT-121; to slab soffit",
          "quantity": 6420.22,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 288909.9,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4727
          },
          "extra_columns": {
            "Basement [C]": "676",
            "GF & Podium [D]": "2,726",
            "Tower 1 [E]": "598",
            "Tower 2 [F]": "798",
            "Tower 3 [G]": "1,024",
            "Tower 4 [H]": "598",
            "TOTAL QTY [I]": "6,420",
            "BASEMENTS [M]": "30,420.00",
            "GF & PODIUM [N]": "122,670.00",
            "TOWER 1 [O]": "26,910.00",
            "TOWER 2 [P]": "35,910.00",
            "TOWER 3 [Q]": "46,089.90",
            "TOWER 4 [R]": "26,910.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-K",
          "item_code": "K",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type S-5a; 100mm high skirting",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy paint; solvent free epoxy-based paint system; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type S-5a; 100mm high skirting",
          "quantity": 30868,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 617360,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4729
          },
          "extra_columns": {
            "Basement [C]": "7,501",
            "GF & Podium [D]": "6,918",
            "Tower 1 [E]": "2,953",
            "Tower 2 [F]": "3,361",
            "Tower 3 [G]": "5,174",
            "Tower 4 [H]": "4,961",
            "TOTAL QTY [I]": "30,868",
            "BASEMENTS [M]": "150,020.00",
            "GF & PODIUM [N]": "138,360.00",
            "TOWER 1 [O]": "59,060.00",
            "TOWER 2 [P]": "67,220.00",
            "TOWER 3 [Q]": "103,480.00",
            "TOWER 4 [R]": "99,220.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-L",
          "item_code": "L",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy floor finish; heavy duty; multi-component abrasion resistant epoxy screed; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-555; to floors",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy floor finish; heavy duty; multi-component abrasion resistant epoxy screed; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-555; to floors",
          "quantity": 18462,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 923100,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4733
          },
          "extra_columns": {
            "Basement [C]": "2,258",
            "GF & Podium [D]": "4,908",
            "Tower 1 [E]": "2,569",
            "Tower 2 [F]": "3,103",
            "Tower 3 [G]": "2,931",
            "Tower 4 [H]": "2,693",
            "TOTAL QTY [I]": "18,462",
            "BASEMENTS [M]": "112,900.00",
            "GF & PODIUM [N]": "245,400.00",
            "TOWER 1 [O]": "128,450.00",
            "TOWER 2 [P]": "155,150.00",
            "TOWER 3 [Q]": "146,550.00",
            "TOWER 4 [R]": "134,650.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-M",
          "item_code": "M",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy floor finish; heavy duty; multi-component abrasion resistant epoxy screed; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-555; anti-slip; to stairs",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy floor finish; heavy duty; multi-component abrasion resistant epoxy screed; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-555; anti-slip; to stairs",
          "quantity": 11689,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 584450,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4735
          },
          "extra_columns": {
            "Basement [C]": "813",
            "GF & Podium [D]": "1,502",
            "Tower 1 [E]": "2,128",
            "Tower 2 [F]": "2,507",
            "Tower 3 [G]": "2,410",
            "Tower 4 [H]": "2,329",
            "TOTAL QTY [I]": "11,689",
            "BASEMENTS [M]": "40,650.00",
            "GF & PODIUM [N]": "75,100.00",
            "TOWER 1 [O]": "106,400.00",
            "TOWER 2 [P]": "125,350.00",
            "TOWER 3 [Q]": "120,500.00",
            "TOWER 4 [R]": "116,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-N",
          "item_code": "N",
          "section": "DECORATIONS",
          "heading_path": [
            "Polyurethane traffic coating; UV stable, multi-layered, durable, anti-skid; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-571; to floors; to parking",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Polyurethane traffic coating; UV stable, multi-layered, durable, anti-skid; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-571; to floors; to parking",
          "quantity": 80467,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 4023350,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4739
          },
          "extra_columns": {
            "Basement [C]": "50,669",
            "GF & Podium [D]": "29,798",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "80,467",
            "BASEMENTS [M]": "2,533,450.00",
            "GF & PODIUM [N]": "1,489,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-P",
          "item_code": "P",
          "section": "DECORATIONS",
          "heading_path": [
            "Polyurethane traffic coating; UV stable, multi-layered, durable, anti-skid; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-571; to floors; to ramp",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Polyurethane traffic coating; UV stable, multi-layered, durable, anti-skid; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-571; to floors; to ramp",
          "quantity": 2054,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 102700,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4741
          },
          "extra_columns": {
            "Basement [C]": "1,352",
            "GF & Podium [D]": "702",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,054",
            "BASEMENTS [M]": "67,600.00",
            "GF & PODIUM [N]": "35,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-Q",
          "item_code": "Q",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy floor coating system; multi-component solvent-free epoxy coating; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-552; to stairs",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy floor coating system; multi-component solvent-free epoxy coating; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-552; to stairs",
          "quantity": 11689,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 584450,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4745
          },
          "extra_columns": {
            "Basement [C]": "813",
            "GF & Podium [D]": "1,502",
            "Tower 1 [E]": "2,128",
            "Tower 2 [F]": "2,507",
            "Tower 3 [G]": "2,410",
            "Tower 4 [H]": "2,329",
            "TOTAL QTY [I]": "11,689",
            "BASEMENTS [M]": "40,650.00",
            "GF & PODIUM [N]": "75,100.00",
            "TOWER 1 [O]": "106,400.00",
            "TOWER 2 [P]": "125,350.00",
            "TOWER 3 [Q]": "120,500.00",
            "TOWER 4 [R]": "116,450.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-R",
          "item_code": "R",
          "section": "DECORATIONS",
          "heading_path": [
            "Epoxy floor coating system; multi-component solvent-free epoxy coating; including surface preparation, base and final coat, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FLH-552; to floors",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Epoxy floor coating system; multi-component solvent-free epoxy coating; including surface preparation, base and final coat, accessories and all ancillary works as necessary — Type FLH-552; to floors",
          "quantity": 281,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 14050,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4747
          },
          "extra_columns": {
            "Basement [C]": "110",
            "GF & Podium [D]": "171",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "TOTAL QTY [I]": "281",
            "BASEMENTS [M]": "5,500.00",
            "GF & PODIUM [N]": "8,550.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-S",
          "item_code": "S",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal paint; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "To walls; above suspended ceiling",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal paint; including surface preparation, accessories and all ancillary works as necessary — To walls; above suspended ceiling",
          "quantity": 6603,
          "unit": "m2",
          "rate_aed": 25,
          "amount_aed": 165075,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4751
          },
          "extra_columns": {
            "Basement [C]": "482",
            "GF & Podium [D]": "1,329",
            "Tower 1 [E]": "925",
            "Tower 2 [F]": "1,521",
            "Tower 3 [G]": "1,047",
            "Tower 4 [H]": "1,299",
            "TOTAL QTY [I]": "6,603",
            "BASEMENTS [M]": "12,050.00",
            "GF & PODIUM [N]": "33,225.00",
            "TOWER 1 [O]": "23,125.00",
            "TOWER 2 [P]": "38,025.00",
            "TOWER 3 [Q]": "26,175.00",
            "TOWER 4 [R]": "32,475.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/87-T",
          "item_code": "T",
          "section": "DECORATIONS",
          "heading_path": [
            "Anti-fungal paint; including surface preparation, accessories and all ancillary works as necessary"
          ],
          "own_description": "To slab soffit; above suspended ceiling",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Anti-fungal paint; including surface preparation, accessories and all ancillary works as necessary — To slab soffit; above suspended ceiling",
          "quantity": 6347,
          "unit": "m2",
          "rate_aed": 25,
          "amount_aed": 158675,
          "amount_state": "number",
          "printed_page": "2/J/15",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4753
          },
          "extra_columns": {
            "Basement [C]": "211",
            "GF & Podium [D]": "918",
            "Tower 1 [E]": "1,218",
            "Tower 2 [F]": "1,389",
            "Tower 3 [G]": "1,327",
            "Tower 4 [H]": "1,284",
            "TOTAL QTY [I]": "6,347",
            "BASEMENTS [M]": "5,275.00",
            "GF & PODIUM [N]": "22,950.00",
            "TOWER 1 [O]": "30,450.00",
            "TOWER 2 [P]": "34,725.00",
            "TOWER 3 [Q]": "33,175.00",
            "TOWER 4 [R]": "32,100.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/88",
      "section": "SIGNWRITING",
      "sheet": "2 - Main",
      "source_collection_aed": 1694510,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/88-A",
          "item_code": "A",
          "section": "DECORATIONS",
          "heading_path": [
            "External Work",
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "To ceiling type CS-01",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — External Work — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — To ceiling type CS-01",
          "quantity": 12596,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 251920,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4768
          },
          "extra_columns": {
            "GF & Podium [D]": "239",
            "Tower 1 [E]": "1,843",
            "Tower 2 [F]": "4,383",
            "Tower 3 [G]": "2,072",
            "Tower 4 [H]": "4,059",
            "TOTAL QTY [I]": "12,596",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,780.00",
            "TOWER 1 [O]": "36,860.00",
            "TOWER 2 [P]": "87,660.00",
            "TOWER 3 [Q]": "41,440.00",
            "TOWER 4 [R]": "81,180.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-B",
          "item_code": "B",
          "section": "DECORATIONS",
          "heading_path": [
            "External Work",
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "To ceiling type CS-02",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — External Work — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — To ceiling type CS-02",
          "quantity": 11053,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 221060,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4770
          },
          "extra_columns": {
            "GF & Podium [D]": "627",
            "Tower 1 [E]": "4,923",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5,503",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11,053",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,540.00",
            "TOWER 1 [O]": "98,460.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "110,060.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-C",
          "item_code": "C",
          "section": "DECORATIONS",
          "heading_path": [
            "External Work",
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "To ceiling type CS-03",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — External Work — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — To ceiling type CS-03",
          "quantity": 7043,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 140860,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4772
          },
          "extra_columns": {
            "GF & Podium [D]": "398",
            "Tower 1 [E]": "3,115",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3,530",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7,043",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,960.00",
            "TOWER 1 [O]": "62,300.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "70,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-D",
          "item_code": "D",
          "section": "DECORATIONS",
          "heading_path": [
            "External Work",
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "To ceiling type CS-04",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — External Work — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — To ceiling type CS-04",
          "quantity": 15810,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 316200,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4774
          },
          "extra_columns": {
            "GF & Podium [D]": "845",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "7,875",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "7,090",
            "TOTAL QTY [I]": "15,810",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "157,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "141,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-E",
          "item_code": "E",
          "section": "DECORATIONS",
          "heading_path": [
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "To podium upstand",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — To podium upstand",
          "quantity": 45,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4778
          },
          "extra_columns": {
            "GF & Podium [D]": "45.00",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-F",
          "item_code": "F",
          "section": "DECORATIONS",
          "heading_path": [
            "Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat"
          ],
          "own_description": "Behind Parapet walls",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Prepare and apply external acrylic based paint; Matt finish; colour RAL 7043; type/ RAL 000 85 00/ RAL 050 50 10/ RAL 9016; including preparation, base, final coat — Behind Parapet walls",
          "quantity": 1911,
          "unit": "m2",
          "rate_aed": 20,
          "amount_aed": 38220,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4780
          },
          "extra_columns": {
            "GF & Podium [D]": "0.00",
            "Tower 1 [E]": "455.00",
            "Tower 2 [F]": "503.00",
            "Tower 3 [G]": "450.00",
            "Tower 4 [H]": "503.00",
            "TOTAL QTY [I]": "1,911",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,100.00",
            "TOWER 2 [P]": "10,060.00",
            "TOWER 3 [Q]": "9,000.00",
            "TOWER 4 [R]": "10,060.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-G",
          "item_code": "G",
          "section": "DECORATIONS",
          "heading_path": [
            "Exterior wall cladding system comprising of 50mm thick mineral wool thermal insulation and 12mm thick cementitious fiber board linin with acrylic based paint, including preparation, base, final coat"
          ],
          "own_description": "To external lift core wall",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — DECORATIONS — Exterior wall cladding system comprising of 50mm thick mineral wool thermal insulation and 12mm thick cementitious fiber board linin with acrylic based paint, including preparation, base, final coat — To external lift core wall",
          "quantity": 2726,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 272600,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4784
          },
          "extra_columns": {
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "663",
            "Tower 2 [F]": "700",
            "Tower 3 [G]": "663",
            "Tower 4 [H]": "700",
            "TOTAL QTY [I]": "2,726",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "66,300.00",
            "TOWER 2 [P]": "70,000.00",
            "TOWER 3 [Q]": "66,300.00",
            "TOWER 4 [R]": "70,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-H",
          "item_code": "H",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 614; straight arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Type 614; straight arrow",
          "quantity": 162,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 16200,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4791
          },
          "extra_columns": {
            "Basement [C]": "94",
            "GF & Podium [D]": "68",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "162",
            "BASEMENTS [M]": "9,400.00",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-J",
          "item_code": "J",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 615; right turn arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Type 615; right turn arrow",
          "quantity": 83,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 8300,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4793
          },
          "extra_columns": {
            "Basement [C]": "37",
            "GF & Podium [D]": "46",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "3,700.00",
            "GF & PODIUM [N]": "4,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-K",
          "item_code": "K",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 616; left turn arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Type 616; left turn arrow",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 4600,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4795
          },
          "extra_columns": {
            "Basement [C]": "22",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "2,200.00",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-L",
          "item_code": "L",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 617; straight/right arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Type 617; straight/right arrow",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4797
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "300.00",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-M",
          "item_code": "M",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type 618; straight/left arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Type 618; straight/left arrow",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4799
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "200.00",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-N",
          "item_code": "N",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Right/left turn arrow",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Right/left turn arrow",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4801
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "400.00",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-P",
          "item_code": "P",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Parking number sign",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Parking number sign",
          "quantity": 2154,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 193860,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4803
          },
          "extra_columns": {
            "Basement [C]": "1,365",
            "GF & Podium [D]": "789",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,154",
            "BASEMENTS [M]": "122,850.00",
            "GF & PODIUM [N]": "71,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-Q",
          "item_code": "Q",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "PWD sign",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — PWD sign",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 2250,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4805
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "900.00",
            "GF & PODIUM [N]": "1,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/88-R",
          "item_code": "R",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Parking lines; 100mm wide",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Parking lines; 100mm wide",
          "quantity": 22564,
          "unit": "m",
          "rate_aed": 10,
          "amount_aed": 225640,
          "amount_state": "number",
          "printed_page": "2/J/16",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4807
          },
          "extra_columns": {
            "Basement [C]": "13,467",
            "GF & Podium [D]": "9,097",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22,564",
            "BASEMENTS [M]": "134,670.00",
            "GF & PODIUM [N]": "90,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/89",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/89-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Finishes in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION J - FINISHES (2/J) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Finishes in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/J/17",
          "bill_ref": "2",
          "section_ref": "2/J",
          "source": {
            "sheet": "2 - Main",
            "row": 4817
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/90",
      "section": "TOILET ACCESSORIES",
      "sheet": "2 - Main",
      "source_collection_aed": 116340.14,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/90-A",
          "item_code": "A",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-514; sensor soap dispenser",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-514; sensor soap dispenser",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 980,
          "amount_aed": 31360,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4938
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-B",
          "item_code": "B",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-515; wall mounted sensor soap dispenser",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-515; wall mounted sensor soap dispenser",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 432,
          "amount_aed": 432,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4940
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "432.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-C",
          "item_code": "C",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-701; wall mounted soap dispenser",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-701; wall mounted soap dispenser",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 432,
          "amount_aed": 3888,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4942
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,888.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-D",
          "item_code": "D",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-704; robe hook",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-704; robe hook",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 42.43,
          "amount_aed": 1315.33,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4944
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,315.33",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-E",
          "item_code": "E",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-708; drip tray",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-708; drip tray",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 750,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4946
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-F",
          "item_code": "F",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-709; pull out recycle bin",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-709; pull out recycle bin",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4948
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-G",
          "item_code": "G",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-710; urinal divider",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-710; urinal divider",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 1980,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4950
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-H",
          "item_code": "H",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-711; handicap backrest",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-711; handicap backrest",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4952
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-J",
          "item_code": "J",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-711; toilet paper holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-711; toilet paper holder",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4954
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-K",
          "item_code": "K",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-712; swing up grab bar with integral toilet paper holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-712; swing up grab bar with integral toilet paper holder",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 595,
          "amount_aed": 2975,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4956
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,975.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-L",
          "item_code": "L",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-713; L-shaped grab bar",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-713; L-shaped grab bar",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 585,
          "amount_aed": 1755,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,755.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-M",
          "item_code": "M",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-714; shower seat",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-714; shower seat",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-N",
          "item_code": "N",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-715; horizontal grab bar",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-715; horizontal grab bar",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 595,
          "amount_aed": 1785,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,785.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-P",
          "item_code": "P",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-716; tilted mirror",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-716; tilted mirror",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 29000,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-Q",
          "item_code": "Q",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-716; tilted mirror ADA",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-716; tilted mirror ADA",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-R",
          "item_code": "R",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-717; tissue holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-717; tissue holder",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 115.58,
          "amount_aed": 3582.98,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,582.98",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-S",
          "item_code": "S",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-718; recessed paper towel dispenser/waste receptacle",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-718; recessed paper towel dispenser/waste receptacle",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 690,
          "amount_aed": 2760,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-T",
          "item_code": "T",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-719; recessed automatic hand dryer",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-719; recessed automatic hand dryer",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 998,
          "amount_aed": 12974,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,974.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-U",
          "item_code": "U",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-720; baby changing station",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-720; baby changing station",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2270,
          "amount_aed": 11350,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/90-V",
          "item_code": "V",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-721; shower rod",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-721; shower rod",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 332.83,
          "amount_aed": 332.83,
          "amount_state": "number",
          "printed_page": "2/K/1",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "332.83",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/91",
      "section": "TOILET ACCESSORIES",
      "sheet": "2 - Main",
      "source_collection_aed": 3593625.04,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/91-A",
          "item_code": "A",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-721; paper towel dispenser with waste bin",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-721; paper towel dispenser with waste bin",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 3020,
          "amount_aed": 27180,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-B",
          "item_code": "B",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-722; waste bin with lid",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-722; waste bin with lid",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 560,
          "amount_aed": 9520,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-C",
          "item_code": "C",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-723; waste bin",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-723; waste bin",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 520,
          "amount_aed": 2600,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-D",
          "item_code": "D",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-724; handicap - automatic towel dispenser",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-724; handicap - automatic towel dispenser",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 102.41,
          "amount_aed": 512.05,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4992
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "512.05",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-E",
          "item_code": "E",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-771 - Urinal privacy screen",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-771 - Urinal privacy screen",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 330,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4994
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-F",
          "item_code": "F",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type GL-101; size 600 x 1200mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — Type GL-101; size 600 x 1200mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 273.6,
          "amount_aed": 1094.4,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4996
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,094.40",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-G",
          "item_code": "G",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "FXG-501; wall clear mirror: size 600 x 900mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — FXG-501; wall clear mirror: size 600 x 900mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 370,
          "amount_aed": 1850,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 4998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-H",
          "item_code": "H",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "FXG-501; wall clear mirror: size 600 x 1200mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Common Areas — FXG-501; wall clear mirror: size 600 x 1200mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 490,
          "amount_aed": 1960,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-J",
          "item_code": "J",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-701; roll holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-701; roll holder",
          "quantity": 3494,
          "unit": "Nr.",
          "rate_aed": 115.58,
          "amount_aed": 403836.52,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5004
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "816",
            "Tower 2 [F]": "873",
            "Tower 3 [G]": "878",
            "Tower 4 [H]": "824",
            "TOTAL QTY [I]": "3,494",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,904.74",
            "TOWER 1 [O]": "94,313.28",
            "TOWER 2 [P]": "100,901.34",
            "TOWER 3 [Q]": "101,479.24",
            "TOWER 4 [R]": "95,237.92",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-K",
          "item_code": "K",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-702; bath towel holder 600mm",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-702; bath towel holder 600mm",
          "quantity": 2395,
          "unit": "Nr.",
          "rate_aed": 158,
          "amount_aed": 378410,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5006
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "71",
            "Tower 1 [E]": "542",
            "Tower 2 [F]": "590",
            "Tower 3 [G]": "616",
            "Tower 4 [H]": "576",
            "TOTAL QTY [I]": "2,395",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,218.00",
            "TOWER 1 [O]": "85,636.00",
            "TOWER 2 [P]": "93,220.00",
            "TOWER 3 [Q]": "97,328.00",
            "TOWER 4 [R]": "91,008.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-L",
          "item_code": "L",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-703; towel ring",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-703; towel ring",
          "quantity": 3257,
          "unit": "Nr.",
          "rate_aed": 134.6,
          "amount_aed": 438392.19999999995,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "772",
            "Tower 2 [F]": "794",
            "Tower 3 [G]": "824",
            "Tower 4 [H]": "769",
            "TOTAL QTY [I]": "3,257",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,190.80",
            "TOWER 1 [O]": "103,911.20",
            "TOWER 2 [P]": "106,872.40",
            "TOWER 3 [Q]": "110,910.40",
            "TOWER 4 [R]": "103,507.40",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-M",
          "item_code": "M",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-704; double ring",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-704; double ring",
          "quantity": 3257,
          "unit": "Nr.",
          "rate_aed": 74.6,
          "amount_aed": 242972.19999999998,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5010
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "772",
            "Tower 2 [F]": "794",
            "Tower 3 [G]": "824",
            "Tower 4 [H]": "769",
            "TOTAL QTY [I]": "3,257",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,310.80",
            "TOWER 1 [O]": "57,591.20",
            "TOWER 2 [P]": "59,232.40",
            "TOWER 3 [Q]": "61,470.40",
            "TOWER 4 [R]": "57,367.40",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-N",
          "item_code": "N",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-706; bath towel holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-706; bath towel holder",
          "quantity": 227,
          "unit": "Nr.",
          "rate_aed": 102.41,
          "amount_aed": 23247.07,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5012
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "227",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "512.05",
            "TOWER 1 [O]": "4,710.86",
            "TOWER 2 [P]": "7,066.29",
            "TOWER 3 [Q]": "5,325.32",
            "TOWER 4 [R]": "5,632.55",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-P",
          "item_code": "P",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-707; robe hook",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-707; robe hook",
          "quantity": 179,
          "unit": "Nr.",
          "rate_aed": 42.43,
          "amount_aed": 7594.97,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5014
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "68",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "54",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "127.29",
            "TOWER 1 [O]": "42.43",
            "TOWER 2 [P]": "2,885.24",
            "TOWER 3 [Q]": "2,248.79",
            "TOWER 4 [R]": "2,291.22",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-Q",
          "item_code": "Q",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-708; dip tray",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-708; dip tray",
          "quantity": 1630,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 244500,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5016
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "407",
            "Tower 2 [F]": "390",
            "Tower 3 [G]": "407",
            "Tower 4 [H]": "376",
            "TOTAL QTY [I]": "1,630",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,500.00",
            "TOWER 1 [O]": "61,050.00",
            "TOWER 2 [P]": "58,500.00",
            "TOWER 3 [Q]": "61,050.00",
            "TOWER 4 [R]": "56,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-R",
          "item_code": "R",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-709; pull out recycle bins",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-709; pull out recycle bins",
          "quantity": 1630,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 978000,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5018
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "407",
            "Tower 2 [F]": "390",
            "Tower 3 [G]": "407",
            "Tower 4 [H]": "376",
            "TOTAL QTY [I]": "1,630",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,000.00",
            "TOWER 1 [O]": "244,200.00",
            "TOWER 2 [P]": "234,000.00",
            "TOWER 3 [Q]": "244,200.00",
            "TOWER 4 [R]": "225,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-S",
          "item_code": "S",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Sanitary accessories",
            "Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-724; bath towel holder",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Sanitary accessories — Sanitary accessories; fixed to tiled or plastered concrete or blockwork; including connections, supports, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-724; bath towel holder",
          "quantity": 243,
          "unit": "Nr.",
          "rate_aed": 102.41,
          "amount_aed": 24885.629999999997,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5020
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "243",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "819.28",
            "TOWER 1 [O]": "9,421.72",
            "TOWER 2 [P]": "4,608.45",
            "TOWER 3 [Q]": "5,325.32",
            "TOWER 4 [R]": "4,710.86",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-T",
          "item_code": "T",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 550 x 1280mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 550 x 1280mm high",
          "quantity": 227,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 108960,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5024
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "227",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "21,600.00",
            "TOWER 2 [P]": "33,120.00",
            "TOWER 3 [Q]": "25,440.00",
            "TOWER 4 [R]": "26,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-U",
          "item_code": "U",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 720 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 720 x 1130mm high",
          "quantity": 592,
          "unit": "Nr.",
          "rate_aed": 550,
          "amount_aed": 325600,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5026
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "173",
            "Tower 3 [G]": "156",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "592",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,250.00",
            "TOWER 1 [O]": "50,600.00",
            "TOWER 2 [P]": "95,150.00",
            "TOWER 3 [Q]": "85,800.00",
            "TOWER 4 [R]": "85,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-V",
          "item_code": "V",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 810 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 810 x 1130mm high",
          "quantity": 591,
          "unit": "Nr.",
          "rate_aed": 620,
          "amount_aed": 366420,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5028
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "136",
            "Tower 2 [F]": "141",
            "Tower 3 [G]": "156",
            "Tower 4 [H]": "139",
            "TOTAL QTY [I]": "591",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,780.00",
            "TOWER 1 [O]": "84,320.00",
            "TOWER 2 [P]": "87,420.00",
            "TOWER 3 [Q]": "96,720.00",
            "TOWER 4 [R]": "86,180.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/91-W",
          "item_code": "W",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 835 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 835 x 1130mm high",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 640,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "2/K/2",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5030
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/92",
      "section": "KIDS PLAY AREA",
      "sheet": "2 - Main",
      "source_collection_aed": 1006438.04,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/92-A",
          "item_code": "A",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 985 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 985 x 1130mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 281960,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5042
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,600.00",
            "TOWER 1 [O]": "66,880.00",
            "TOWER 2 [P]": "64,600.00",
            "TOWER 3 [Q]": "76,000.00",
            "TOWER 4 [R]": "66,880.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-B",
          "item_code": "B",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1000 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 1000 x 1130mm high",
          "quantity": 75,
          "unit": "Nr.",
          "rate_aed": 770,
          "amount_aed": 57750,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5044
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "49",
            "Tower 2 [F]": "17",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "37,730.00",
            "TOWER 2 [P]": "13,090.00",
            "TOWER 3 [Q]": "3,850.00",
            "TOWER 4 [R]": "1,540.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-C",
          "item_code": "C",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1020 x 1130mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 1020 x 1130mm high",
          "quantity": 749,
          "unit": "Nr.",
          "rate_aed": 780,
          "amount_aed": 584220,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5046
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "749",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,500.00",
            "TOWER 1 [O]": "138,840.00",
            "TOWER 2 [P]": "132,600.00",
            "TOWER 3 [Q]": "156,000.00",
            "TOWER 4 [R]": "137,280.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-D",
          "item_code": "D",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1300 x 1280mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 1300 x 1280mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1130,
          "amount_aed": 2260,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5048
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,130.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,130.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-E",
          "item_code": "E",
          "section": "TOILET ACCESSORIES",
          "heading_path": [
            "Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1320 x 1230mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET ACCESSORIES — Tempered mirror; type GL-101; 6mm thick clear mirror with metal frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Size 1320 x 1230mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 28600,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "19,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-F",
          "item_code": "F",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Size 6200 x 2900mm high to Gym Pavillion including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Size 6200 x 2900mm high to Gym Pavillion including MT-104 mirror frame",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5054
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-G",
          "item_code": "G",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Gym Mirror. Size 7200 x 2900mm high to Gym Pavillion including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Gym Mirror. Size 7200 x 2900mm high to Gym Pavillion including MT-104 mirror frame",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5056
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-H",
          "item_code": "H",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Gym Mirror. Size 1700 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Gym Mirror. Size 1700 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5058
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-J",
          "item_code": "J",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Gym Mirror. Size 2100 x 3100mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Gym Mirror. Size 2100 x 3100mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5060
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-K",
          "item_code": "K",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Gym Mirror. Size 2650 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Gym Mirror. Size 2650 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5062
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-L",
          "item_code": "L",
          "section": "GYM ACCESSORIES",
          "heading_path": [],
          "own_description": "Gym Mirror. Size 3250 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GYM ACCESSORIES — Gym Mirror. Size 3250 x 2650mm high to Tower 2 and 4 Gym including MT-104 mirror frame",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5064
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-M",
          "item_code": "M",
          "section": "KITCHEN ACCESSORIES",
          "heading_path": [
            "Kitchen sink; stainless steel double bowl with drain, plugs and sink lever mixer; including connections, supports, sealants, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1160 x 475mm wide; to staff pantry and security room",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — KITCHEN ACCESSORIES — Kitchen sink; stainless steel double bowl with drain, plugs and sink lever mixer; including connections, supports, sealants, accessories and all ancillary works as necessary — Size 1160 x 475mm wide; to staff pantry and security room",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-N",
          "item_code": "N",
          "section": "KITCHEN ACCESSORIES",
          "heading_path": [
            "Kitchen sink; stainless steel with drain, plugs and single lever mixer; including connections, supports, sealants, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 835 x 500mm wide; to guard rooms",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — KITCHEN ACCESSORIES — Kitchen sink; stainless steel with drain, plugs and single lever mixer; including connections, supports, sealants, accessories and all ancillary works as necessary — Size 835 x 500mm wide; to guard rooms",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 237.01,
          "amount_aed": 948.04,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "948.04",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/92-P",
          "item_code": "P",
          "section": "KIDS PLAY AREA",
          "heading_path": [
            "Magnetic Writable Board to Kids Play area"
          ],
          "own_description": "GL-102",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — KIDS PLAY AREA — Magnetic Writable Board to Kids Play area — GL-102",
          "quantity": 10,
          "unit": "m2",
          "rate_aed": 250,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/K/3",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5082
          },
          "extra_columns": {
            "GF & Podium [D]": "10.00",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/93",
      "section": "SIGNAGE AND WAYFINDING",
      "sheet": "2 - Main",
      "source_collection_aed": 1971170,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/93-A",
          "item_code": "A",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type BLR-01; In case of fire do not use lifts, use stairs",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type BLR-01; In case of fire do not use lifts, use stairs",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 206,
          "amount_aed": 1030,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5096
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "618.00",
            "GF & PODIUM [N]": "412.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-B",
          "item_code": "B",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type BTD-01; BOH door sign (single leaf door)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type BTD-01; BOH door sign (single leaf door)",
          "quantity": 734,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 202584,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5098
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "62",
            "Tower 1 [E]": "147",
            "Tower 2 [F]": "173",
            "Tower 3 [G]": "165",
            "Tower 4 [H]": "160",
            "TOTAL QTY [I]": "734",
            "BASEMENTS [M]": "7,452.00",
            "GF & PODIUM [N]": "17,112.00",
            "TOWER 1 [O]": "40,572.00",
            "TOWER 2 [P]": "47,748.00",
            "TOWER 3 [Q]": "45,540.00",
            "TOWER 4 [R]": "44,160.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-C",
          "item_code": "C",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type BTD-02; BOH door sign (double leaf door)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type BTD-02; BOH door sign (double leaf door)",
          "quantity": 43,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 11868,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5100
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "552.00",
            "GF & PODIUM [N]": "8,832.00",
            "TOWER 1 [O]": "552.00",
            "TOWER 2 [P]": "552.00",
            "TOWER 3 [Q]": "828.00",
            "TOWER 4 [R]": "552.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-D",
          "item_code": "D",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type BWC-01; BOH restroom sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type BWC-01; BOH restroom sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 1104,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5102
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,104.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-E",
          "item_code": "E",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ECM-01; column marker",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ECM-01; column marker",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 716,
          "amount_aed": 5728,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5104
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "2,864.00",
            "GF & PODIUM [N]": "2,864.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-F",
          "item_code": "F",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type EID-04; tower identity sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type EID-04; tower identity sign",
          "quantity": 27,
          "unit": "Nr.",
          "rate_aed": 1579,
          "amount_aed": 42633,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5106
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "23,685.00",
            "GF & PODIUM [N]": "18,948.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-G",
          "item_code": "G",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ERR-01; exterior rules/disclaimer sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ERR-01; exterior rules/disclaimer sign",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 769,
          "amount_aed": 1538,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5108
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,538.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-H",
          "item_code": "H",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ESC-03; stair egress sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ESC-03; stair egress sign",
          "quantity": 507,
          "unit": "Nr.",
          "rate_aed": 530,
          "amount_aed": 268710,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5110
          },
          "extra_columns": {
            "Basement [C]": "26",
            "GF & Podium [D]": "57",
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "114",
            "Tower 3 [G]": "108",
            "Tower 4 [H]": "104",
            "TOTAL QTY [I]": "507",
            "BASEMENTS [M]": "13,780.00",
            "GF & PODIUM [N]": "30,210.00",
            "TOWER 1 [O]": "51,940.00",
            "TOWER 2 [P]": "60,420.00",
            "TOWER 3 [Q]": "57,240.00",
            "TOWER 4 [R]": "55,120.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-J",
          "item_code": "J",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ESC-04; emergency evacuation map",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ESC-04; emergency evacuation map",
          "quantity": 252,
          "unit": "Nr.",
          "rate_aed": 737,
          "amount_aed": 185724,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5112
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "72",
            "Tower 2 [F]": "55",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "51",
            "TOTAL QTY [I]": "252",
            "BASEMENTS [M]": "5,896.00",
            "GF & PODIUM [N]": "10,318.00",
            "TOWER 1 [O]": "53,064.00",
            "TOWER 2 [P]": "40,535.00",
            "TOWER 3 [Q]": "38,324.00",
            "TOWER 4 [R]": "37,587.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-K",
          "item_code": "K",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ETD-01; loading/unloading",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ETD-01; loading/unloading",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1497,
          "amount_aed": 4491,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5114
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,491.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-L",
          "item_code": "L",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ETR-01; parking sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ETR-01; parking sign",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1995,
          "amount_aed": 9975,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5116
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,975.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-M",
          "item_code": "M",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ETR-02; suspended vehicular sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ETR-02; suspended vehicular sign",
          "quantity": 85,
          "unit": "Nr.",
          "rate_aed": 3155,
          "amount_aed": 268175,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5118
          },
          "extra_columns": {
            "Basement [C]": "33",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "104,115.00",
            "GF & PODIUM [N]": "164,060.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-N",
          "item_code": "N",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ETR-03; tower 1 lift lobby",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ETR-03; tower 1 lift lobby",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 3155,
          "amount_aed": 37860,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5120
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "18,930.00",
            "GF & PODIUM [N]": "18,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-P",
          "item_code": "P",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type ETR-04; parking bay marker",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type ETR-04; parking bay marker",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 3580,
          "amount_aed": 42960,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5122
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "10,740.00",
            "GF & PODIUM [N]": "32,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-Q",
          "item_code": "Q",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FAN-01; room number",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FAN-01; room number",
          "quantity": 1674,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 577530,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5124
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "380",
            "Tower 2 [F]": "418",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,674",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,795.00",
            "TOWER 1 [O]": "131,100.00",
            "TOWER 2 [P]": "144,210.00",
            "TOWER 3 [Q]": "156,630.00",
            "TOWER 4 [R]": "141,795.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-R",
          "item_code": "R",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FDI-01; FOH interior directional",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FDI-01; FOH interior directional",
          "quantity": 408,
          "unit": "Nr.",
          "rate_aed": 426,
          "amount_aed": 173808,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5126
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "97",
            "Tower 3 [G]": "101",
            "Tower 4 [H]": "90",
            "TOTAL QTY [I]": "408",
            "BASEMENTS [M]": "2,556.00",
            "GF & PODIUM [N]": "10,224.00",
            "TOWER 1 [O]": "38,340.00",
            "TOWER 2 [P]": "41,322.00",
            "TOWER 3 [Q]": "43,026.00",
            "TOWER 4 [R]": "38,340.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-S",
          "item_code": "S",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FFE-01; firefighting equipment",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FFE-01; firefighting equipment",
          "quantity": 514,
          "unit": "Nr.",
          "rate_aed": 197,
          "amount_aed": 101258,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5128
          },
          "extra_columns": {
            "Basement [C]": "40",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "114",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "105",
            "TOTAL QTY [I]": "514",
            "BASEMENTS [M]": "7,880.00",
            "GF & PODIUM [N]": "10,244.00",
            "TOWER 1 [O]": "18,518.00",
            "TOWER 2 [P]": "22,458.00",
            "TOWER 3 [Q]": "21,473.00",
            "TOWER 4 [R]": "20,685.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-T",
          "item_code": "T",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FFE-02; fire sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FFE-02; fire sign",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 197,
          "amount_aed": 3546,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,546.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-U",
          "item_code": "U",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FID-01; FOH area identity",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FID-01; FOH area identity",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 552,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "552.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/93-V",
          "item_code": "V",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FLD-01; in lift directional identity",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FLD-01; in lift directional identity",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 1254,
          "amount_aed": 30096,
          "amount_state": "number",
          "printed_page": "2/K/4",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5134
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,096.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/94",
      "section": "SIGNAGE AND WAYFINDING",
      "sheet": "2 - Main",
      "source_collection_aed": 2274534.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/94-A",
          "item_code": "A",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FLN-01; FOH lift level number",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FLN-01; FOH lift level number",
          "quantity": 907,
          "unit": "Nr.",
          "rate_aed": 512,
          "amount_aed": 464384,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5148
          },
          "extra_columns": {
            "Basement [C]": "29",
            "GF & Podium [D]": "64",
            "Tower 1 [E]": "186",
            "Tower 2 [F]": "220",
            "Tower 3 [G]": "206",
            "Tower 4 [H]": "202",
            "TOTAL QTY [I]": "907",
            "BASEMENTS [M]": "14,848.00",
            "GF & PODIUM [N]": "32,768.00",
            "TOWER 1 [O]": "95,232.00",
            "TOWER 2 [P]": "112,640.00",
            "TOWER 3 [Q]": "105,472.00",
            "TOWER 4 [R]": "103,424.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-B",
          "item_code": "B",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FLR-01; FOH lift regulatory sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FLR-01; FOH lift regulatory sign",
          "quantity": 921,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 254196,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5150
          },
          "extra_columns": {
            "Basement [C]": "35",
            "GF & Podium [D]": "71",
            "Tower 1 [E]": "186",
            "Tower 2 [F]": "220",
            "Tower 3 [G]": "207",
            "Tower 4 [H]": "202",
            "TOTAL QTY [I]": "921",
            "BASEMENTS [M]": "9,660.00",
            "GF & PODIUM [N]": "19,596.00",
            "TOWER 1 [O]": "51,336.00",
            "TOWER 2 [P]": "60,720.00",
            "TOWER 3 [Q]": "57,132.00",
            "TOWER 4 [R]": "55,752.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-C",
          "item_code": "C",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FRR-01; interior rules/disclaimer sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FRR-01; interior rules/disclaimer sign",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 206,
          "amount_aed": 2266,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5152
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,266.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-D",
          "item_code": "D",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FSS-01; stairs sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FSS-01; stairs sign",
          "quantity": 484,
          "unit": "Nr.",
          "rate_aed": 530,
          "amount_aed": 256520,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5154
          },
          "extra_columns": {
            "Basement [C]": "28",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "98",
            "Tower 2 [F]": "114",
            "Tower 3 [G]": "106",
            "Tower 4 [H]": "104",
            "TOTAL QTY [I]": "484",
            "BASEMENTS [M]": "14,840.00",
            "GF & PODIUM [N]": "18,020.00",
            "TOWER 1 [O]": "51,940.00",
            "TOWER 2 [P]": "60,420.00",
            "TOWER 3 [Q]": "56,180.00",
            "TOWER 4 [R]": "55,120.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-E",
          "item_code": "E",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FTD-01; FOH door sign (single leaf door)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FTD-01; FOH door sign (single leaf door)",
          "quantity": 689,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 190164,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5156
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "57",
            "Tower 1 [E]": "141",
            "Tower 2 [F]": "166",
            "Tower 3 [G]": "155",
            "Tower 4 [H]": "153",
            "TOTAL QTY [I]": "689",
            "BASEMENTS [M]": "4,692.00",
            "GF & PODIUM [N]": "15,732.00",
            "TOWER 1 [O]": "38,916.00",
            "TOWER 2 [P]": "45,816.00",
            "TOWER 3 [Q]": "42,780.00",
            "TOWER 4 [R]": "42,228.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-F",
          "item_code": "F",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FTD-02; FOH door sign (double leaf door)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FTD-02; FOH door sign (double leaf door)",
          "quantity": 55,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 15180,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5158
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "2,760.00",
            "GF & PODIUM [N]": "8,832.00",
            "TOWER 1 [O]": "828.00",
            "TOWER 2 [P]": "1,104.00",
            "TOWER 3 [Q]": "828.00",
            "TOWER 4 [R]": "828.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-G",
          "item_code": "G",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FTD-03; FOH push/pull door sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FTD-03; FOH push/pull door sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 105,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5160
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-H",
          "item_code": "H",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Type FWC-01 FOH restroom sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Type FWC-01 FOH restroom sign",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 3312,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5162
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,312.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-J",
          "item_code": "J",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "Internal Signage"
          ],
          "own_description": "Retail sign by others",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — Internal Signage — Retail sign by others",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5164
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/94-K",
          "item_code": "K",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type EID-01; main identity sign (EMAAR)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type EID-01; main identity sign (EMAAR)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 235290,
          "amount_aed": 470580,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5168
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "470,580.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-L",
          "item_code": "L",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type EID-02; main identity sign (ADDRESS)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type EID-02; main identity sign (ADDRESS)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 235290,
          "amount_aed": 470580,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5170
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "470,580.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-M",
          "item_code": "M",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type EID-03; tower identity sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type EID-03; tower identity sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1579,
          "amount_aed": 6316,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5172
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,316.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-N",
          "item_code": "N",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type EPC-01; pool depth marker",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type EPC-01; pool depth marker",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 807,
          "amount_aed": 2421,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5174
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,421.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-P",
          "item_code": "P",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type ESC-02; assembly point sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type ESC-02; assembly point sign",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 206,
          "amount_aed": 412,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5176
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "412.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-Q",
          "item_code": "Q",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type ETD-01; loading/unloading",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type ETD-01; loading/unloading",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1497,
          "amount_aed": 1497,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5178
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,497.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-R",
          "item_code": "R",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type ETR-02; suspended vehicular sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type ETR-02; suspended vehicular sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3580,
          "amount_aed": 14320,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5180
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-S",
          "item_code": "S",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type EVD-01; vehicular directional sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type EVD-01; vehicular directional sign",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 9058.5,
          "amount_aed": 117760.5,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5182
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "117,760.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-T",
          "item_code": "T",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type FFE-02; fire sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type FFE-02; fire sign",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 276,
          "amount_aed": 552,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5184
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "552.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-U",
          "item_code": "U",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type FRR-01; interior rules/disclaimer sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type FRR-01; interior rules/disclaimer sign",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 206,
          "amount_aed": 1030,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5186
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-V",
          "item_code": "V",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type FRS-01; no smoking sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type FRS-01; no smoking sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 206,
          "amount_aed": 824,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5188
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "824.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-W",
          "item_code": "W",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type FTD-02; FOH door sign (double leaf door)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type FTD-02; FOH door sign (double leaf door)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 1380,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5190
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/94-X",
          "item_code": "X",
          "section": "SIGNAGE AND WAYFINDING",
          "heading_path": [
            "Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary",
            "External Signage"
          ],
          "own_description": "Type FTD-03; FOH push/pull door sign",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — SIGNAGE AND WAYFINDING — Signage and wayfinding; in English and Arabic text; including finishes, fixings, accessories and all ancillary works as necessary — External Signage — Type FTD-03; FOH push/pull door sign",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 105,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/K/5",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5192
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/95",
      "section": "PARKING ACCESSORIES",
      "sheet": "2 - Main",
      "source_collection_aed": 1144474.03,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/95-A",
          "item_code": "A",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Wheel stopper; precast concrete fixed to floor slab and painted RAL 1018, 25x25mm edge chamfer; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FXP-801; size 1900 x 150 x 100mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Wheel stopper; precast concrete fixed to floor slab and painted RAL 1018, 25x25mm edge chamfer; including fixings, finishes, accessories and all ancillary works as necessary — Type FXP-801; size 1900 x 150 x 100mm high",
          "quantity": 2047,
          "unit": "Nr.",
          "rate_aed": 265,
          "amount_aed": 542455,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5208
          },
          "extra_columns": {
            "Basement [C]": "1,288",
            "GF & Podium [D]": "759",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,047",
            "BASEMENTS [M]": "341,320.00",
            "GF & PODIUM [N]": "201,135.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-B",
          "item_code": "B",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type EXH-301; 100mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary — Type EXH-301; 100mm high",
          "quantity": 2969,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5212
          },
          "extra_columns": {
            "Basement [C]": "1,134",
            "GF & Podium [D]": "1,835",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,969",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-C",
          "item_code": "C",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm high; to ramps",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary — 150mm high; to ramps",
          "quantity": 609,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5214
          },
          "extra_columns": {
            "Basement [C]": "346",
            "GF & Podium [D]": "263",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "609",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-D",
          "item_code": "D",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Kerbs; precast concrete fixed to floor slab; including fixings, finishes, accessories and all ancillary works as necessary — 150mm high",
          "quantity": 1677,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 419250,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5218
          },
          "extra_columns": {
            "Basement [C]": "696",
            "GF & Podium [D]": "981",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,677",
            "BASEMENTS [M]": "174,000.00",
            "GF & PODIUM [N]": "245,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-E",
          "item_code": "E",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Rubber speed humps; solid, integrally coloured ultraviolet (UV) stabilized, high impact resistance, black & RAL 1018 colour in alternate strips; fixed to slab with two expansion joint; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FXP-881; 300mm wide x 40mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Rubber speed humps; solid, integrally coloured ultraviolet (UV) stabilized, high impact resistance, black & RAL 1018 colour in alternate strips; fixed to slab with two expansion joint; including finishes, fixings, accessories and all ancillary works as necessary — Type FXP-881; 300mm wide x 40mm high",
          "quantity": 55,
          "unit": "Nr.",
          "rate_aed": 670,
          "amount_aed": 36850,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5222
          },
          "extra_columns": {
            "Basement [C]": "29",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "19,430.00",
            "GF & PODIUM [N]": "17,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-F",
          "item_code": "F",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Parabolic mirrors; impact proof, vandal safe polycarbonate with aluminium foil backing; mounted wall; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type FXG-581; size 500mm diameter",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Parabolic mirrors; impact proof, vandal safe polycarbonate with aluminium foil backing; mounted wall; including finishes, fixings, accessories and all ancillary works as necessary — Type FXG-581; size 500mm diameter",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5226
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "9,000.00",
            "GF & PODIUM [N]": "7,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-G",
          "item_code": "G",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 1800 x 1900mm wide (2Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 1800 x 1900mm wide (2Nrs)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520.28,
          "amount_aed": 3520.28,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.28",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-H",
          "item_code": "H",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 2450 x 1900mm wide (3Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 2450 x 1900mm wide (3Nrs)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4498.13,
          "amount_aed": 4498.13,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,498.13",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-J",
          "item_code": "J",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3100 x 1900mm wide (4Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 3100 x 1900mm wide (4Nrs)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5867.13,
          "amount_aed": 11734.26,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,734.26",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-K",
          "item_code": "K",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 3750 x 1900mm wide (5Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 3750 x 1900mm wide (5Nrs)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7676.16,
          "amount_aed": 7676.16,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,676.16",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-L",
          "item_code": "L",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 4400 x 1900mm wide (6Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 4400 x 1900mm wide (6Nrs)",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 8409.55,
          "amount_aed": 25228.649999999998,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,228.65",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-M",
          "item_code": "M",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 5050 x 1900mm wide (7Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 5050 x 1900mm wide (7Nrs)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 9582.97,
          "amount_aed": 19165.94,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,165.94",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-N",
          "item_code": "N",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 5600 x 1900mm wide (8Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 5600 x 1900mm wide (8Nrs)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10658.61,
          "amount_aed": 10658.61,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,658.61",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/95-P",
          "item_code": "P",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 5750 x 1900mm wide (8Nrs)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bicycle rack; size 75 x 75mm polyester powder coated galvanised steel pipe surface mounted on base plate 10 x 150mm; including fixings, finishes, accessories and all ancillary works as necessary — Size 5750 x 1900mm wide (8Nrs)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 11734.25,
          "amount_aed": 46937,
          "amount_state": "number",
          "printed_page": "2/K/6",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "46,937.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/96",
      "section": "PARKING ACCESSORIES",
      "sheet": "2 - Main",
      "source_collection_aed": 621910,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/96-A",
          "item_code": "A",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Corner guards; modular wall mounted rubber wall/corner protection system; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type TRM-495; size 100 x 100mm",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Corner guards; modular wall mounted rubber wall/corner protection system; including accessories and all ancillary works as necessary — Type TRM-495; size 100 x 100mm",
          "quantity": 2676,
          "unit": "Nr.",
          "rate_aed": 194,
          "amount_aed": 519144,
          "amount_state": "number",
          "printed_page": "2/K/7",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5256
          },
          "extra_columns": {
            "Basement [C]": "1,620",
            "GF & Podium [D]": "1,056",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,676",
            "BASEMENTS [M]": "314,280.00",
            "GF & PODIUM [N]": "204,864.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/96-B",
          "item_code": "B",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Crash guards; 2 rows of 35mm thick; in high impact resistant rubber profile fixed to wall with chemical anchor fasteners; including fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type TRM-491; 200mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Crash guards; 2 rows of 35mm thick; in high impact resistant rubber profile fixed to wall with chemical anchor fasteners; including fixings, accessories and all ancillary works as necessary — Type TRM-491; 200mm high",
          "quantity": 687,
          "unit": "m",
          "rate_aed": 66,
          "amount_aed": 45342,
          "amount_state": "number",
          "printed_page": "2/K/7",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5260
          },
          "extra_columns": {
            "Basement [C]": "233",
            "GF & Podium [D]": "454",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "687",
            "BASEMENTS [M]": "15,378.00",
            "GF & PODIUM [N]": "29,964.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/96-C",
          "item_code": "C",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Bollards; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ground floor",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Bollards; including fixings, finishes, accessories and all ancillary works as necessary — To ground floor",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2178,
          "amount_aed": 17424,
          "amount_state": "number",
          "printed_page": "2/K/7",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5264
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,424.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/96-D",
          "item_code": "D",
          "section": "PARKING ACCESSORIES",
          "heading_path": [
            "Pipe Protection"
          ],
          "own_description": "In parking Areas",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARKING ACCESSORIES — Pipe Protection — In parking Areas",
          "quantity": 160,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 40000,
          "amount_state": "number",
          "printed_page": "2/K/7",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5268
          },
          "extra_columns": {
            "Basement [C]": "88",
            "GF & Podium [D]": "72",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "22,000.00",
            "GF & PODIUM [N]": "18,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/97",
      "section": "PARTITIONS",
      "sheet": "2 - Main",
      "source_collection_aed": 19434546.95,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/97-A",
          "item_code": "A",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 100mm thick",
          "quantity": 50793.76,
          "unit": "m2",
          "rate_aed": 135,
          "amount_aed": 6857157.600000001,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,055",
            "Tower 1 [E]": "10,906",
            "Tower 2 [F]": "13,443",
            "Tower 3 [G]": "12,395",
            "Tower 4 [H]": "11,995",
            "TOTAL QTY [I]": "50,794",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "277,425.00",
            "TOWER 1 [O]": "1,472,310.00",
            "TOWER 2 [P]": "1,814,805.00",
            "TOWER 3 [Q]": "1,673,292.60",
            "TOWER 4 [R]": "1,619,325.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-B",
          "item_code": "B",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 150mm thick",
          "quantity": 21,
          "unit": "m2",
          "rate_aed": 160,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "1,600.00",
            "TOWER 2 [P]": "320.00",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-C",
          "item_code": "C",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 200mm thick",
          "quantity": 148,
          "unit": "m2",
          "rate_aed": 221,
          "amount_aed": 32708,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "78",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "148",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,238.00",
            "TOWER 1 [O]": "5,746.00",
            "TOWER 2 [P]": "4,862.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,862.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-D",
          "item_code": "D",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "250mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 250mm thick",
          "quantity": 43,
          "unit": "m2",
          "rate_aed": 294,
          "amount_aed": 12642,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,642.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-E",
          "item_code": "E",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "300mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 300mm thick",
          "quantity": 9,
          "unit": "m2",
          "rate_aed": 353,
          "amount_aed": 3177,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,177.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-F",
          "item_code": "F",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 50mm thick",
          "quantity": 29,
          "unit": "m2",
          "rate_aed": 113,
          "amount_aed": 3277,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,582.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,695.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-G",
          "item_code": "G",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 100mm thick",
          "quantity": 36616.229999999996,
          "unit": "m2",
          "rate_aed": 225,
          "amount_aed": 8238651.749999999,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,589",
            "Tower 1 [E]": "8,663",
            "Tower 2 [F]": "9,425",
            "Tower 3 [G]": "8,360",
            "Tower 4 [H]": "8,579",
            "TOTAL QTY [I]": "36,616",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "357,525.00",
            "TOWER 1 [O]": "1,949,175.00",
            "TOWER 2 [P]": "2,120,625.00",
            "TOWER 3 [Q]": "1,881,051.75",
            "TOWER 4 [R]": "1,930,275.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-H",
          "item_code": "H",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 150mm thick",
          "quantity": 2923.6,
          "unit": "m2",
          "rate_aed": 245,
          "amount_aed": 716282,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "177",
            "Tower 1 [E]": "423",
            "Tower 2 [F]": "728",
            "Tower 3 [G]": "858",
            "Tower 4 [H]": "738",
            "TOTAL QTY [I]": "2,924",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,365.00",
            "TOWER 1 [O]": "103,635.00",
            "TOWER 2 [P]": "178,360.00",
            "TOWER 3 [Q]": "210,112.00",
            "TOWER 4 [R]": "180,810.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-J",
          "item_code": "J",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 200mm thick",
          "quantity": 61,
          "unit": "m2",
          "rate_aed": 300,
          "amount_aed": 18300,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "52",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "15,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-K",
          "item_code": "K",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "250mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 250mm thick",
          "quantity": 89,
          "unit": "m2",
          "rate_aed": 392,
          "amount_aed": 34888,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "89",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,248.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,640.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-L",
          "item_code": "L",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "300mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick one side regular plasterboard, one side moisture resistant plasterboard, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 300mm thick",
          "quantity": 6,
          "unit": "m2",
          "rate_aed": 470,
          "amount_aed": 2820,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-M",
          "item_code": "M",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 100mm thick",
          "quantity": 11271.68,
          "unit": "m2",
          "rate_aed": 235,
          "amount_aed": 2648844.8000000003,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "676",
            "Tower 1 [E]": "2,136",
            "Tower 2 [F]": "2,739",
            "Tower 3 [G]": "3,033",
            "Tower 4 [H]": "2,688",
            "TOTAL QTY [I]": "11,272",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "158,860.00",
            "TOWER 1 [O]": "501,960.00",
            "TOWER 2 [P]": "643,665.00",
            "TOWER 3 [Q]": "712,679.80",
            "TOWER 4 [R]": "631,680.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-N",
          "item_code": "N",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 150mm thick",
          "quantity": 3193.8,
          "unit": "m2",
          "rate_aed": 266,
          "amount_aed": 849550.8,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "233",
            "Tower 1 [E]": "961",
            "Tower 2 [F]": "628",
            "Tower 3 [G]": "732",
            "Tower 4 [H]": "640",
            "TOTAL QTY [I]": "3,194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "61,978.00",
            "TOWER 1 [O]": "255,626.00",
            "TOWER 2 [P]": "167,048.00",
            "TOWER 3 [Q]": "194,658.80",
            "TOWER 4 [R]": "170,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-P",
          "item_code": "P",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 200mm thick",
          "quantity": 5,
          "unit": "m2",
          "rate_aed": 315,
          "amount_aed": 1575,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,575.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/97-Q",
          "item_code": "Q",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "250mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on each side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 250mm thick",
          "quantity": 27,
          "unit": "m2",
          "rate_aed": 419,
          "amount_aed": 11313,
          "amount_state": "number",
          "printed_page": "2/K/8",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,313.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/98",
      "section": "PARTITIONS",
      "sheet": "2 - Main",
      "source_collection_aed": 6064629.98,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/98-A",
          "item_code": "A",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 50mm thick",
          "quantity": 569.84,
          "unit": "m2",
          "rate_aed": 113,
          "amount_aed": 64391.920000000006,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5357
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "93",
            "Tower 2 [F]": "184",
            "Tower 3 [G]": "141",
            "Tower 4 [H]": "131",
            "TOTAL QTY [I]": "570",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,373.00",
            "TOWER 1 [O]": "10,509.00",
            "TOWER 2 [P]": "20,792.00",
            "TOWER 3 [Q]": "15,914.92",
            "TOWER 4 [R]": "14,803.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-B",
          "item_code": "B",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 100mm thick",
          "quantity": 11135.34,
          "unit": "m2",
          "rate_aed": 225,
          "amount_aed": 2505451.5,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5359
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "480",
            "Tower 1 [E]": "2,478",
            "Tower 2 [F]": "2,877",
            "Tower 3 [G]": "2,676",
            "Tower 4 [H]": "2,624",
            "TOTAL QTY [I]": "11,135",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "108,000.00",
            "TOWER 1 [O]": "557,550.00",
            "TOWER 2 [P]": "647,325.00",
            "TOWER 3 [Q]": "602,176.50",
            "TOWER 4 [R]": "590,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-C",
          "item_code": "C",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 150mm thick",
          "quantity": 3755.81,
          "unit": "m2",
          "rate_aed": 245,
          "amount_aed": 920173.45,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5361
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "144",
            "Tower 1 [E]": "750",
            "Tower 2 [F]": "949",
            "Tower 3 [G]": "1,007",
            "Tower 4 [H]": "906",
            "TOTAL QTY [I]": "3,756",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,280.00",
            "TOWER 1 [O]": "183,750.00",
            "TOWER 2 [P]": "232,505.00",
            "TOWER 3 [Q]": "246,668.45",
            "TOWER 4 [R]": "221,970.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-D",
          "item_code": "D",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 200mm thick",
          "quantity": 2284.06,
          "unit": "m2",
          "rate_aed": 300,
          "amount_aed": 685218,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5363
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "573",
            "Tower 2 [F]": "556",
            "Tower 3 [G]": "520",
            "Tower 4 [H]": "532",
            "TOTAL QTY [I]": "2,284",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,900.00",
            "TOWER 1 [O]": "171,900.00",
            "TOWER 2 [P]": "166,800.00",
            "TOWER 3 [Q]": "156,018.00",
            "TOWER 4 [R]": "159,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-E",
          "item_code": "E",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "250mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 250mm thick",
          "quantity": 14,
          "unit": "m2",
          "rate_aed": 392,
          "amount_aed": 5488,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5365
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,352.00",
            "TOWER 1 [O]": "784.00",
            "TOWER 2 [P]": "784.00",
            "TOWER 3 [Q]": "784.00",
            "TOWER 4 [R]": "784.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-F",
          "item_code": "F",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "300mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick moisture resistant plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 300mm thick",
          "quantity": 941.96,
          "unit": "m2",
          "rate_aed": 470,
          "amount_aed": 442721.2,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5367
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "223",
            "Tower 2 [F]": "219",
            "Tower 3 [G]": "252",
            "Tower 4 [H]": "220",
            "TOTAL QTY [I]": "942",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,160.00",
            "TOWER 1 [O]": "104,810.00",
            "TOWER 2 [P]": "102,930.00",
            "TOWER 3 [Q]": "118,421.20",
            "TOWER 4 [R]": "103,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-G",
          "item_code": "G",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 50mm thick",
          "quantity": 2599.69,
          "unit": "m2",
          "rate_aed": 89,
          "amount_aed": 231372.41,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5371
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "487",
            "Tower 1 [E]": "399",
            "Tower 2 [F]": "599",
            "Tower 3 [G]": "604",
            "Tower 4 [H]": "511",
            "TOTAL QTY [I]": "2,600",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,343.00",
            "TOWER 1 [O]": "35,511.00",
            "TOWER 2 [P]": "53,311.00",
            "TOWER 3 [Q]": "53,728.41",
            "TOWER 4 [R]": "45,479.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-H",
          "item_code": "H",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 100mm thick",
          "quantity": 5655.7,
          "unit": "m2",
          "rate_aed": 135,
          "amount_aed": 763519.5,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5373
          },
          "extra_columns": {
            "Basement [C]": "134",
            "GF & Podium [D]": "568",
            "Tower 1 [E]": "1,265",
            "Tower 2 [F]": "1,267",
            "Tower 3 [G]": "1,223",
            "Tower 4 [H]": "1,199",
            "TOTAL QTY [I]": "5,656",
            "BASEMENTS [M]": "18,090.00",
            "GF & PODIUM [N]": "76,680.00",
            "TOWER 1 [O]": "170,775.00",
            "TOWER 2 [P]": "171,045.00",
            "TOWER 3 [Q]": "165,064.50",
            "TOWER 4 [R]": "161,865.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-J",
          "item_code": "J",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 150mm thick",
          "quantity": 2449.2,
          "unit": "m2",
          "rate_aed": 160,
          "amount_aed": 391872,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5375
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "147",
            "Tower 1 [E]": "654",
            "Tower 2 [F]": "522",
            "Tower 3 [G]": "588",
            "Tower 4 [H]": "538",
            "TOTAL QTY [I]": "2,449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,520.00",
            "TOWER 1 [O]": "104,640.00",
            "TOWER 2 [P]": "83,520.00",
            "TOWER 3 [Q]": "94,112.00",
            "TOWER 4 [R]": "86,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-K",
          "item_code": "K",
          "section": "PARTITIONS",
          "heading_path": [
            "Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "200mm thick",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Drywall partitions; comprising two layer  of 12.7mm thick regular plasterboard on one side, frames, 50mm thick glass wool; including adhesives, supports, brackets, accessories and all ancillary works as necessary — 200mm thick",
          "quantity": 32,
          "unit": "m2",
          "rate_aed": 221,
          "amount_aed": 7072,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,536.00",
            "TOWER 1 [O]": "884.00",
            "TOWER 2 [P]": "884.00",
            "TOWER 3 [Q]": "884.00",
            "TOWER 4 [R]": "884.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-L",
          "item_code": "L",
          "section": "PARTITIONS",
          "heading_path": [
            "Glass partition; 10mm thick fully tempered and hear soak tested clear glass; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type IW-01; size 7350 x 3100mm high; to meeting room",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Glass partition; 10mm thick fully tempered and hear soak tested clear glass; including fixings, finishes, accessories and all ancillary works as necessary — Type IW-01; size 7350 x 3100mm high; to meeting room",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42390,
          "amount_aed": 42390,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,390.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/98-M",
          "item_code": "M",
          "section": "PARTITIONS",
          "heading_path": [
            "Glass partition; 10mm thick fully tempered and hear soak tested clear glass; including fixings, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for single glazed pivot door; size 1150 x 2200mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — PARTITIONS — Glass partition; 10mm thick fully tempered and hear soak tested clear glass; including fixings, finishes, accessories and all ancillary works as necessary — Extra over for single glazed pivot door; size 1150 x 2200mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4960,
          "amount_aed": 4960,
          "amount_state": "number",
          "printed_page": "2/K/9",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/99",
      "section": "TOILET PARTITION",
      "sheet": "2 - Main",
      "source_collection_aed": 2825712.5,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/99-A",
          "item_code": "A",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type GL-105; shower glass partition; size 940 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Type GL-105; shower glass partition; size 940 x 2000mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1762.5,
          "amount_aed": 7050,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5406
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-B",
          "item_code": "B",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type GL-105; shower glass partition; size 980 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Type GL-105; shower glass partition; size 980 x 2000mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1837.5,
          "amount_aed": 7350,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5408
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-C",
          "item_code": "C",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type GL-105; shower glass partition; size 1020 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Type GL-105; shower glass partition; size 1020 x 2000mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1912.5,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5410
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-D",
          "item_code": "D",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over doors; overall size; 700mm x 2100mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower and toilet glass partition; fixed glass with doors; frosted glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Extra over doors; overall size; 700mm x 2100mm high",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Incl.",
          "amount_state": "text",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5412
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/99-E",
          "item_code": "E",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 900 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 900 x 2000mm high",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 1687.5,
          "amount_aed": 626062.5,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5418
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,875.00",
            "TOWER 1 [O]": "148,500.00",
            "TOWER 2 [P]": "143,437.50",
            "TOWER 3 [Q]": "168,750.00",
            "TOWER 4 [R]": "148,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-F",
          "item_code": "F",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1190 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1190 x 2000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5420
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-G",
          "item_code": "G",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1240 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1240 x 2000mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5422
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-H",
          "item_code": "H",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1280 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1280 x 2000mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 2400,
          "amount_aed": 345600,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5424
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "108,000.00",
            "TOWER 3 [Q]": "124,800.00",
            "TOWER 4 [R]": "110,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-J",
          "item_code": "J",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1330 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1330 x 2000mm high",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 492500,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5426
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "115,000.00",
            "TOWER 2 [P]": "112,500.00",
            "TOWER 3 [Q]": "130,000.00",
            "TOWER 4 [R]": "115,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-K",
          "item_code": "K",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1400 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1400 x 2000mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 511875,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "120,750.00",
            "TOWER 2 [P]": "118,125.00",
            "TOWER 3 [Q]": "136,500.00",
            "TOWER 4 [R]": "120,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-L",
          "item_code": "L",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1460 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1460 x 2000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5430
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-M",
          "item_code": "M",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1470 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1470 x 2000mm high",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 2762.5,
          "amount_aed": 127075,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5432
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,525.00",
            "TOWER 1 [O]": "121,550.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-N",
          "item_code": "N",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1600 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1600 x 2000mm high",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5434
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-P",
          "item_code": "P",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1610 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1610 x 2000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3025,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-Q",
          "item_code": "Q",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1800 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 1800 x 2000mm high",
          "quantity": 377,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "377",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-R",
          "item_code": "R",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 2440 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 2440 x 2000mm high",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 4575,
          "amount_aed": 91500,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "91,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-S",
          "item_code": "S",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 4110 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 4110 x 2000mm high",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 7712.5,
          "amount_aed": 370200,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "185,100.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "185,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-T",
          "item_code": "T",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 5820 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 5820 x 2000mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 10912.5,
          "amount_aed": 87300,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "43,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "43,650.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-U",
          "item_code": "U",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 7760 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Type D07; shower glass partition; size 7760 x 2000mm high",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 14550,
          "amount_aed": 145500,
          "amount_state": "number",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "72,750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "72,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/99-V",
          "item_code": "V",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Clear Glass"
          ],
          "own_description": "Extra over doors; overall size; 700mm x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Clear Glass — Extra over doors; overall size; 700mm x 2000mm high",
          "quantity": 1041,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Incl",
          "amount_state": "text",
          "printed_page": "2/K/10",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "229",
            "Tower 2 [F]": "268",
            "Tower 3 [G]": "261",
            "Tower 4 [H]": "254",
            "TOTAL QTY [I]": "1,041",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/100",
      "section": "TOILET PARTITION",
      "sheet": "2 - Main",
      "source_collection_aed": 5972835,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/100-A",
          "item_code": "A",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1080 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1080 x 2000mm high",
          "quantity": 195,
          "unit": "Nr.",
          "rate_aed": 2300,
          "amount_aed": 448500,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5460
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "195",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,800.00",
            "TOWER 1 [O]": "105,800.00",
            "TOWER 2 [P]": "103,500.00",
            "TOWER 3 [Q]": "119,600.00",
            "TOWER 4 [R]": "105,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-B",
          "item_code": "B",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1190 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1190 x 2000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2537.5,
          "amount_aed": 5075,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5462
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,075.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-C",
          "item_code": "C",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1240 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1240 x 2000mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2650,
          "amount_aed": 13250,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5464
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-D",
          "item_code": "D",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1330 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1330 x 2000mm high",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2837.5,
          "amount_aed": 14187.5,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5466
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,187.50",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-E",
          "item_code": "E",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1350 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1350 x 2000mm high",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2875,
          "amount_aed": 5750,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-F",
          "item_code": "F",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1460 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1460 x 2000mm high",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 3112.5,
          "amount_aed": 149400,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5470
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,225.00",
            "TOWER 1 [O]": "143,175.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-G",
          "item_code": "G",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1530 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1530 x 2000mm high",
          "quantity": 568,
          "unit": "Nr.",
          "rate_aed": 3262.5,
          "amount_aed": 1853100,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5472
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "134",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "152",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "568",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,725.00",
            "TOWER 1 [O]": "437,175.00",
            "TOWER 2 [P]": "424,125.00",
            "TOWER 3 [Q]": "495,900.00",
            "TOWER 4 [R]": "437,175.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-H",
          "item_code": "H",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1600 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1600 x 2000mm high",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 3406.25,
          "amount_aed": 1253500,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5474
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,250.00",
            "TOWER 1 [O]": "299,750.00",
            "TOWER 2 [P]": "286,125.00",
            "TOWER 3 [Q]": "340,625.00",
            "TOWER 4 [R]": "299,750.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-J",
          "item_code": "J",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1630 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1630 x 2000mm high",
          "quantity": 144,
          "unit": "Nr.",
          "rate_aed": 3475,
          "amount_aed": 500400,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5476
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,475.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "156,375.00",
            "TOWER 3 [Q]": "180,700.00",
            "TOWER 4 [R]": "159,850.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-K",
          "item_code": "K",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1800 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1800 x 2000mm high",
          "quantity": 381,
          "unit": "Nr.",
          "rate_aed": 3837.5,
          "amount_aed": 1462087.5,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5478
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "381",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,237.50",
            "TOWER 1 [O]": "345,375.00",
            "TOWER 2 [P]": "330,025.00",
            "TOWER 3 [Q]": "383,750.00",
            "TOWER 4 [R]": "337,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-L",
          "item_code": "L",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 1830 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 1830 x 2000mm high",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 3900,
          "amount_aed": 101400,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5480
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "70,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-M",
          "item_code": "M",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 2960 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 2960 x 2000mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6300,
          "amount_aed": 25200,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5482
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-N",
          "item_code": "N",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Type D07; shower glass partition; size 4760 x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Type D07; shower glass partition; size 4760 x 2000mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 10125,
          "amount_aed": 60750,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5484
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "30,375.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "30,375.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-P",
          "item_code": "P",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary",
            "Fluted Tinted Glass"
          ],
          "own_description": "Extra over doors; overall size; 700mm x 2000mm high",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Shower glass partition; fixed glass with doors; glass; 10mm thick; including ironmongery, fixings, accessories and all ancillary works as necessary — Fluted Tinted Glass — Extra over doors; overall size; 700mm x 2000mm high",
          "quantity": 1754,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Incl.",
          "amount_state": "text",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5486
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "406",
            "Tower 2 [F]": "416",
            "Tower 3 [G]": "458",
            "Tower 4 [H]": "413",
            "TOTAL QTY [I]": "1,754",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/100-Q",
          "item_code": "Q",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Cubicle partition and doors; high-pressure compact laminate on both side; including finishes, ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LP-106; washroom cubicles; size 3970 x 1600 x 2700mm high (4 doors)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Cubicle partition and doors; high-pressure compact laminate on both side; including finishes, ironmongery, fixings, accessories and all ancillary works as necessary — Type LP-106; washroom cubicles; size 3970 x 1600 x 2700mm high (4 doors)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35660,
          "amount_aed": 35660,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5490
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/100-R",
          "item_code": "R",
          "section": "TOILET PARTITION",
          "heading_path": [
            "Cubicle partition and doors; high-pressure compact laminate on both side; including finishes, ironmongery, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LP-106; washroom cubicles; size 4970 x 1600 x 2700mm high (5 doors)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — TOILET PARTITION — Cubicle partition and doors; high-pressure compact laminate on both side; including finishes, ironmongery, fixings, accessories and all ancillary works as necessary — Type LP-106; washroom cubicles; size 4970 x 1600 x 2700mm high (5 doors)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 44575,
          "amount_aed": 44575,
          "amount_state": "number",
          "printed_page": "2/K/11",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5492
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "44,575.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/101",
      "section": "WASTE CHUTES",
      "sheet": "2 - Main",
      "source_collection_aed": 2562420,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/101-A",
          "item_code": "A",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications"
          ],
          "own_description": "600mm diameter; penthouse house to ground floor level (total floors 51 Nr.)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications — 600mm diameter; penthouse house to ground floor level (total floors 51 Nr.)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 275500,
          "amount_aed": 551000,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5506
          },
          "extra_columns": {
            "Tower 1 [E]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "551,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-B",
          "item_code": "B",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications"
          ],
          "own_description": "600mm diameter; penthouse house to ground floor level (total floors 59 Nr.)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications — 600mm diameter; penthouse house to ground floor level (total floors 59 Nr.)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 318710,
          "amount_aed": 637420,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5508
          },
          "extra_columns": {
            "Tower 2 [F]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "637,420.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-C",
          "item_code": "C",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications"
          ],
          "own_description": "600mm diameter; penthouse house to ground floor level (total floors 55 Nr.)",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Waste chutes (wet & dry) made of stainless steel, 1.9 2.5mm thick; additional thickness of 1.7 2.5mm thick chute metal with bracing to structure; comprising intake (hopper) doors with self closing arrangement, hinged with frame of size 500mm x 500mm at each floor; including sanitization and disinfection systems, air vents, cleaning and fire fighting inlets, necessary framing, fittings and accessories; as Waste Management Specifications — 600mm diameter; penthouse house to ground floor level (total floors 55 Nr.)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 297100,
          "amount_aed": 1188400,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5510
          },
          "extra_columns": {
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "594,200.00",
            "TOWER 4 [R]": "594,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-D",
          "item_code": "D",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Dry Waste; capacity 1100L",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Dry Waste; capacity 1100L",
          "quantity": 42,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 105000,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5515
          },
          "extra_columns": {
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "32,500.00",
            "TOWER 3 [Q]": "22,500.00",
            "TOWER 4 [R]": "25,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-E",
          "item_code": "E",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Green Waste; capacity 1100L",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Green Waste; capacity 1100L",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5517
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,500.00",
            "TOWER 2 [P]": "2,500.00",
            "TOWER 3 [Q]": "2,500.00",
            "TOWER 4 [R]": "2,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-F",
          "item_code": "F",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Hazardous Waste; capacity 1100L",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Hazardous Waste; capacity 1100L",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5519
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,500.00",
            "TOWER 2 [P]": "2,500.00",
            "TOWER 3 [Q]": "2,500.00",
            "TOWER 4 [R]": "2,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-G",
          "item_code": "G",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Wet Waste; capacity 1100L",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Wet Waste; capacity 1100L",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 32500,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5521
          },
          "extra_columns": {
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,500.00",
            "TOWER 2 [P]": "10,000.00",
            "TOWER 3 [Q]": "7,500.00",
            "TOWER 4 [R]": "7,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-H",
          "item_code": "H",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Wheelie Bin Compactor",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Wheelie Bin Compactor",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5523
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-J",
          "item_code": "J",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Insect Killer",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Insect Killer",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1725,
          "amount_aed": 6900,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5525
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,725.00",
            "TOWER 2 [P]": "1,725.00",
            "TOWER 3 [Q]": "1,725.00",
            "TOWER 4 [R]": "1,725.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/101-K",
          "item_code": "K",
          "section": "WASTE CHUTES",
          "heading_path": [
            "Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications"
          ],
          "own_description": "Hose Reel",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — WASTE CHUTES — Supply and installation of facility solid waste handling equipment; as per Waste Management Specifications — Hose Reel",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2300,
          "amount_aed": 9200,
          "amount_state": "number",
          "printed_page": "2/K/12",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5527
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,300.00",
            "TOWER 2 [P]": "2,300.00",
            "TOWER 3 [Q]": "2,300.00",
            "TOWER 4 [R]": "2,300.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/102",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/102-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Accessories in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION K - ACCESSORIES (2/K) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Accessories in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/K/13",
          "bill_ref": "2",
          "section_ref": "2/K",
          "source": {
            "sheet": "2 - Main",
            "row": 5549
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/103",
      "section": "WHITE GOODS",
      "sheet": "2 - Main",
      "source_collection_aed": 24242209.13,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/103-A",
          "item_code": "A",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-101; cooker hood 60cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-101; cooker hood 60cm",
          "quantity": 1521,
          "unit": "Nr.",
          "rate_aed": 1119.2,
          "amount_aed": 1702303.2,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "360",
            "Tower 2 [F]": "345",
            "Tower 3 [G]": "404",
            "Tower 4 [H]": "356",
            "TOTAL QTY [I]": "1,521",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "62,675.20",
            "TOWER 1 [O]": "402,912.00",
            "TOWER 2 [P]": "386,124.00",
            "TOWER 3 [Q]": "452,156.80",
            "TOWER 4 [R]": "398,435.20",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-B",
          "item_code": "B",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-102; cooker hood 90cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-102; cooker hood 90cm",
          "quantity": 227,
          "unit": "Nr.",
          "rate_aed": 1427.89,
          "amount_aed": 324131.03,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "227",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,139.45",
            "TOWER 1 [O]": "64,255.05",
            "TOWER 2 [P]": "98,524.41",
            "TOWER 3 [Q]": "75,678.17",
            "TOWER 4 [R]": "78,533.95",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-C",
          "item_code": "C",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-103; gas hob 60cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-103; gas hob 60cm",
          "quantity": 1521,
          "unit": "Nr.",
          "rate_aed": 996.3,
          "amount_aed": 1515372.3,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "360",
            "Tower 2 [F]": "345",
            "Tower 3 [G]": "404",
            "Tower 4 [H]": "356",
            "TOTAL QTY [I]": "1,521",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "55,792.80",
            "TOWER 1 [O]": "358,668.00",
            "TOWER 2 [P]": "343,723.50",
            "TOWER 3 [Q]": "402,505.20",
            "TOWER 4 [R]": "354,682.80",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-D",
          "item_code": "D",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-104; gas hob 90cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-104; gas hob 90cm",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 2737.27,
          "amount_aed": 539242.19,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,686.35",
            "TOWER 1 [O]": "120,439.88",
            "TOWER 2 [P]": "136,863.50",
            "TOWER 3 [Q]": "142,338.04",
            "TOWER 4 [R]": "125,914.42",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-E",
          "item_code": "E",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-105; built-in oven 60cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-105; built-in oven 60cm",
          "quantity": 1521,
          "unit": "Nr.",
          "rate_aed": 3830.13,
          "amount_aed": 5825627.73,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "360",
            "Tower 2 [F]": "345",
            "Tower 3 [G]": "404",
            "Tower 4 [H]": "356",
            "TOTAL QTY [I]": "1,521",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "214,487.28",
            "TOWER 1 [O]": "1,378,846.80",
            "TOWER 2 [P]": "1,321,394.85",
            "TOWER 3 [Q]": "1,547,372.52",
            "TOWER 4 [R]": "1,363,526.28",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-F",
          "item_code": "F",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-106; built-in oven 90cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-106; built-in oven 90cm",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 5958.8,
          "amount_aed": 1173883.6,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5676
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,794.00",
            "TOWER 1 [O]": "262,187.20",
            "TOWER 2 [P]": "297,940.00",
            "TOWER 3 [Q]": "309,857.60",
            "TOWER 4 [R]": "274,104.80",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-G",
          "item_code": "G",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-107; built in dishwasher",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-107; built in dishwasher",
          "quantity": 1748,
          "unit": "Nr.",
          "rate_aed": 3730.65,
          "amount_aed": 6521176.2,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5678
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "457",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,748",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "227,569.65",
            "TOWER 1 [O]": "1,510,913.25",
            "TOWER 2 [P]": "1,544,489.10",
            "TOWER 3 [Q]": "1,704,907.05",
            "TOWER 4 [R]": "1,533,297.15",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-H",
          "item_code": "H",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-108; built in fridge/freezer 60cm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-108; built in fridge/freezer 60cm",
          "quantity": 1748,
          "unit": "Nr.",
          "rate_aed": 3793.56,
          "amount_aed": 6631142.88,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5680
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "457",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,748",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "231,407.16",
            "TOWER 1 [O]": "1,536,391.80",
            "TOWER 2 [P]": "1,570,533.84",
            "TOWER 3 [Q]": "1,733,656.92",
            "TOWER 4 [R]": "1,559,153.16",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-J",
          "item_code": "J",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-111; freestanding cooker",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-111; freestanding cooker",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5682
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-K",
          "item_code": "K",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-112; freestanding fridge",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-112; freestanding fridge",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-L",
          "item_code": "L",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-113; freestanding freezer",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-113; freestanding freezer",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-M",
          "item_code": "M",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-114; freestanding dishwasher",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-114; freestanding dishwasher",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-N",
          "item_code": "N",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-115; under counter built-in fridge",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-115; under counter built-in fridge",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 3110,
          "amount_aed": 9330,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5690
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-P",
          "item_code": "P",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-116; coffee machine",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-116; coffee machine",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5692
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-Q",
          "item_code": "Q",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-117; tv screen",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-117; tv screen",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5694
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-R",
          "item_code": "R",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-118; tv screen",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-118; tv screen",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5696
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-S",
          "item_code": "S",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-119; water dispenser",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-119; water dispenser",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5698
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/103-T",
          "item_code": "T",
          "section": "WHITE GOODS",
          "heading_path": [
            "White goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WG-120; tv screen",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — WHITE GOODS — White goods; including accessories and all ancillary works as necessary — Type WG-120; tv screen",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/1",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5700
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/104",
      "section": "GYM EQUIPMENT",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/104-A",
          "item_code": "A",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-101; run 19\" excite live",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-101; run 19\" excite live",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-B",
          "item_code": "B",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-102; climb 16\" excite live",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-102; climb 16\" excite live",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-C",
          "item_code": "C",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-103; synchro ar 16\" excite live",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-103; synchro ar 16\" excite live",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-D",
          "item_code": "D",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-104; technogym bike",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-104; technogym bike",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5728
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-E",
          "item_code": "E",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-105; skillrow",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-105; skillrow",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5730
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-F",
          "item_code": "F",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-106; lower back fitness bench",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-106; lower back fitness bench",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5732
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-G",
          "item_code": "G",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-107; yoga mat",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-107; yoga mat",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-H",
          "item_code": "H",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-108; crunch bench press",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-108; crunch bench press",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-J",
          "item_code": "J",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-109; multi-power",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-109; multi-power",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-K",
          "item_code": "K",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-110; adjustable bench",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-110; adjustable bench",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5740
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-L",
          "item_code": "L",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-111; two tier dumbbell rack",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-111; two tier dumbbell rack",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-M",
          "item_code": "M",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-112; dumbbells (10 pairs)",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-112; dumbbells (10 pairs)",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-N",
          "item_code": "N",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-113; dual leg curl/leg extension selection 700",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-113; dual leg curl/leg extension selection 700",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-P",
          "item_code": "P",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-114; lat machine selection 700",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-114; lat machine selection 700",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-Q",
          "item_code": "Q",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-115; shoulder press-selection 700",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-115; shoulder press-selection 700",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-R",
          "item_code": "R",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-116; chest press-selection 700",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-116; chest press-selection 700",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5752
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-S",
          "item_code": "S",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-117; skill tools storage",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-117; skill tools storage",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5754
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-T",
          "item_code": "T",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-118; universe wall 2 virtual",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-118; universe wall 2 virtual",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5756
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-U",
          "item_code": "U",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-119; vario 16\" excite live",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-119; vario 16\" excite live",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5758
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-V",
          "item_code": "V",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-120; skill up",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-120; skill up",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-W",
          "item_code": "W",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-121; skillmill",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-121; skillmill",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-X",
          "item_code": "X",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-122; skillrun unity 7000",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-122; skillrun unity 7000",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-Y",
          "item_code": "Y",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-123; plyobox",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-123; plyobox",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5766
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-Z",
          "item_code": "Z",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-124; punching bag",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-124; punching bag",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5768
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/104-AA",
          "item_code": "AA",
          "section": "GYM EQUIPMENT",
          "heading_path": [
            "Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work"
          ],
          "own_description": "Type EQ-125; leg press selection 700",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GYM EQUIPMENT — Supply and installation by Others: Contractor to allow for Co-ordination, attendance and builders work — Type EQ-125; leg press selection 700",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/2",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5770
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/105",
      "section": "BUILDING MANAGEMENT UNIT (BMU)",
      "sheet": "2 - Main",
      "source_collection_aed": 10366000,
      "section_notes": [
        "Note: Refer to the following:",
        "1. Facade access maintenance and strategy plans Drawing Nr. ZD-3250587-MFT-PLN-PDM-FAC-1601-0 to 3604-0",
        "2. Facade access details Drawing Nr. ZD-3250587-MFT-DET-ZZZ-FAC-9601-0 to 9506-0",
        "3. Facade access equipment specifications Document Nr. ZD-3250587-MFT-SPC-ZZ-ZZZ-0002"
      ],
      "items": [
        {
          "id": "2 - Main/105-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Building management unit (BMU); including chassis, machine housing, telescopic mast, jib, telescopic platform, counterweight, controls, safety provisions including connections, supports, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "BMU; maximum reach 22.5m, BMU weight 80760kg, cradle RL 250kg, material WLL 500kg; complete",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Building management unit (BMU); including chassis, machine housing, telescopic mast, jib, telescopic platform, counterweight, controls, safety provisions including connections, supports, fixing materials, accessories and all ancillary works as necessary — BMU; maximum reach 22.5m, BMU weight 80760kg, cradle RL 250kg, material WLL 500kg; complete",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2500000,
          "amount_aed": 5000000,
          "amount_state": "number",
          "printed_page": "2/L/3",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5790
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,500,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,500,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2500000"
          }
        },
        {
          "id": "2 - Main/105-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Building management unit (BMU); including chassis, machine housing, telescopic mast, jib, telescopic platform, counterweight, controls, safety provisions including connections, supports, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "BMU; maximum reach 24m, BMU weight 86975kg, cradle RL 250kg, material WLL 750kg; complete",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Building management unit (BMU); including chassis, machine housing, telescopic mast, jib, telescopic platform, counterweight, controls, safety provisions including connections, supports, fixing materials, accessories and all ancillary works as necessary — BMU; maximum reach 24m, BMU weight 86975kg, cradle RL 250kg, material WLL 750kg; complete",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2500000,
          "amount_aed": 5000000,
          "amount_state": "number",
          "printed_page": "2/L/3",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5792
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,500,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,500,000.00",
            "[S]": "TRUE",
            "[T]": "2500000"
          }
        },
        {
          "id": "2 - Main/105-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "BMU accessories; including fixing materials, signage, supports, brackets, accessories and all ancillary works as necessary",
            "Galvanized mild steel running track; including galvanized steel base plates, clip ears, stainless steel A4/80 u-bolts, high-strength grout, fixings; complete"
          ],
          "own_description": "BMU tracks at 4000mm center to center",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — BMU accessories; including fixing materials, signage, supports, brackets, accessories and all ancillary works as necessary — Galvanized mild steel running track; including galvanized steel base plates, clip ears, stainless steel A4/80 u-bolts, high-strength grout, fixings; complete — BMU tracks at 4000mm center to center",
          "quantity": 183,
          "unit": "m",
          "rate_aed": 2000,
          "amount_aed": 366000,
          "amount_state": "number",
          "printed_page": "2/L/3",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5798
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "47",
            "Tower 3 [G]": "43",
            "Tower 4 [H]": "47",
            "TOTAL QTY [I]": "183",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "92,000.00",
            "TOWER 2 [P]": "94,000.00",
            "TOWER 3 [Q]": "86,000.00",
            "TOWER 4 [R]": "94,000.00",
            "[S]": "TRUE",
            "[T]": "2000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/106",
      "section": "BUILDING MANAGEMENT UNIT (BMU)",
      "sheet": "2 - Main",
      "source_collection_aed": 1671800,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/106-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Floor mounted rope access rail; including trolleys, anchor post, fixings; complete"
          ],
          "own_description": "To roofdeck; min 21kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Floor mounted rope access rail; including trolleys, anchor post, fixings; complete — To roofdeck; min 21kN design load",
          "quantity": 342,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 342000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "86",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "86",
            "Tower 4 [H]": "85",
            "TOTAL QTY [I]": "342",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "86,000.00",
            "TOWER 2 [P]": "85,000.00",
            "TOWER 3 [Q]": "86,000.00",
            "TOWER 4 [R]": "85,000.00",
            "[S]": "TRUE",
            "[T]": "-1000"
          }
        },
        {
          "id": "2 - Main/106-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Face mounted rope access rail; including trolleys, anchor post, transfer points, fixings; complete"
          ],
          "own_description": "To roofdeck; min 21kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Face mounted rope access rail; including trolleys, anchor post, transfer points, fixings; complete — To roofdeck; min 21kN design load",
          "quantity": 255,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 255000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "60",
            "Tower 2 [F]": "70",
            "Tower 3 [G]": "55",
            "Tower 4 [H]": "70",
            "TOTAL QTY [I]": "255",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "60,000.00",
            "TOWER 2 [P]": "70,000.00",
            "TOWER 3 [Q]": "55,000.00",
            "TOWER 4 [R]": "70,000.00",
            "[S]": "TRUE",
            "[T]": "10000"
          }
        },
        {
          "id": "2 - Main/106-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Face mounted rope access rail; including trolleys, anchor post, transfer points, fixings; complete"
          ],
          "own_description": "To podium; min 21kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Face mounted rope access rail; including trolleys, anchor post, transfer points, fixings; complete — To podium; min 21kN design load",
          "quantity": 422,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 422000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "422",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "422",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "422,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/106-D",
          "item_code": "D",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Soffit mounted rope access rail; including trolleys, anchor post, fixings; complete"
          ],
          "own_description": "To access recessed facade; min 21kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Soffit mounted rope access rail; including trolleys, anchor post, fixings; complete — To access recessed facade; min 21kN design load",
          "quantity": 598,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 598000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "173",
            "Tower 2 [F]": "122",
            "Tower 3 [G]": "170",
            "Tower 4 [H]": "133",
            "TOTAL QTY [I]": "598",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "173,000.00",
            "TOWER 2 [P]": "122,000.00",
            "TOWER 3 [Q]": "170,000.00",
            "TOWER 4 [R]": "133,000.00",
            "[S]": "TRUE",
            "[T]": "-40000"
          }
        },
        {
          "id": "2 - Main/106-E",
          "item_code": "E",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Floor mounted floor protection rail; including PPE anchor line, connectors, fixtures. brackets. fixings; complete"
          ],
          "own_description": "To podium deck",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Floor mounted floor protection rail; including PPE anchor line, connectors, fixtures. brackets. fixings; complete — To podium deck",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 1000,
          "amount_aed": 45000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "45",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/106-F",
          "item_code": "F",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Rope access anchors; including stainless steel brackets, fixing materials; complete"
          ],
          "own_description": "To podium; min 15kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Rope access anchors; including stainless steel brackets, fixing materials; complete — To podium; min 15kN design load",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/106-G",
          "item_code": "G",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Rope access anchors; including stainless steel brackets, fixing materials; complete"
          ],
          "own_description": "To roofdeck; min 15kN design load",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Rope access anchors; including stainless steel brackets, fixing materials; complete — To roofdeck; min 15kN design load",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "300.00",
            "TOWER 2 [P]": "300.00",
            "TOWER 3 [Q]": "300.00",
            "TOWER 4 [R]": "300.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/106-H",
          "item_code": "H",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Floor mounted rope access davit; including removable aluminum davit profile, davit fixed socket, removable access hatch, A4 stainless steel anchors, fixings; complete"
          ],
          "own_description": "Maximum reach of 2000mm",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Floor mounted rope access davit; including removable aluminum davit profile, davit fixed socket, removable access hatch, A4 stainless steel anchors, fixings; complete — Maximum reach of 2000mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/L/4",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/107",
      "section": "BUILDING MANAGEMENT UNIT (BMU)",
      "sheet": "2 - Main",
      "source_collection_aed": 125000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/107-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Mobile tower scaffold; including outriggers/stabilizers, platforms with integrated hatches, end frames, tag ID system and accessories; complete"
          ],
          "own_description": "Platform height of 8m to 12m",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Mobile tower scaffold; including outriggers/stabilizers, platforms with integrated hatches, end frames, tag ID system and accessories; complete — Platform height of 8m to 12m",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5878
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/107-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Telescopic water fed pole;including carbon fiber poles, hoses and filters; complete"
          ],
          "own_description": "Working height of 12m",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Telescopic water fed pole;including carbon fiber poles, hoses and filters; complete — Working height of 12m",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 75000,
          "amount_state": "number",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5882
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "75,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/107-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 1",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — To tower 1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5886
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "Included",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/107-D",
          "item_code": "D",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 2",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — To tower 2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5888
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "Included",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/107-E",
          "item_code": "E",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 3",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — To tower 3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5890
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "Included",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/107-F",
          "item_code": "F",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 4",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — To tower 4",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5892
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "Included",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/107-G",
          "item_code": "G",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "Allow to mobile elevated work platform (MEWP) including accessories and all ancillary works as necessary",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — Allow to mobile elevated work platform (MEWP) including accessories and all ancillary works as necessary",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5894
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/107-H",
          "item_code": "H",
          "section": "BUILDING MANAGEMENT UNIT (BMU)",
          "heading_path": [
            "Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "Allow to panel transport trolley including accessories and all ancillary works as necessary",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — BUILDING MANAGEMENT UNIT (BMU) — Allow to detent pin BMU restraints; including painted restraint socket, fixings, brackets, accessories and all ancillary works as necessary — Allow to panel transport trolley including accessories and all ancillary works as necessary",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/5",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5896
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/108",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/108-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Equipment in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION L - EQUIPMENT (2/L) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Equipment in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/L/6",
          "bill_ref": "2",
          "section_ref": "2/L",
          "source": {
            "sheet": "2 - Main",
            "row": 5928
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/109",
      "section": "LOOSE FF&E",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/109-A",
          "item_code": "A",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-101; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-101; coffee table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6045
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-B",
          "item_code": "B",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-102; side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-102; side table",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6047
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-C",
          "item_code": "C",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-103; side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-103; side table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6049
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-D",
          "item_code": "D",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-104; console behind sofa",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-104; console behind sofa",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-E",
          "item_code": "E",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-105; console",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-105; console",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-F",
          "item_code": "F",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-106; side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-106; side table",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-G",
          "item_code": "G",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-107; table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-107; table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-H",
          "item_code": "H",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-108; console",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-108; console",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-J",
          "item_code": "J",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-109; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-109; coffee table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-K",
          "item_code": "K",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-110; side table vintage bronze",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-110; side table vintage bronze",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-L",
          "item_code": "L",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-111; side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-111; side table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-M",
          "item_code": "M",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-112; side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-112; side table",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-N",
          "item_code": "N",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-113; communal table travertine",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-113; communal table travertine",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-P",
          "item_code": "P",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-114; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-114; coffee table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-Q",
          "item_code": "Q",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-115; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-115; coffee table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-R",
          "item_code": "R",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-116; armchairs side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-116; armchairs side table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-S",
          "item_code": "S",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-117; sofa side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-117; sofa side table",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-T",
          "item_code": "T",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-118; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-118; coffee table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-U",
          "item_code": "U",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-119; coffee table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-119; coffee table",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-V",
          "item_code": "V",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-120; dining table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-120; dining table",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6083
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-W",
          "item_code": "W",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-121; console",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-121; console",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/109-X",
          "item_code": "X",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-122; gaming area side table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-122; gaming area side table",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/1",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/110",
      "section": "LOOSE FF&E",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/110-A",
          "item_code": "A",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-123; kids table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-123; kids table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-B",
          "item_code": "B",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-124; pool table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-124; pool table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-C",
          "item_code": "C",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-125; foosball table",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-125; foosball table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-D",
          "item_code": "D",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Case goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type CG-126; shower bench",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Case goods; including accessories and all ancillary works as necessary — Type CG-126; shower bench",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-E",
          "item_code": "E",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-101; seating area loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-101; seating area loose rug",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-F",
          "item_code": "F",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-102; big table loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-102; big table loose rug",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-G",
          "item_code": "G",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-103; rectangular loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-103; rectangular loose rug",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-H",
          "item_code": "H",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-104; rectangular loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-104; rectangular loose rug",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-J",
          "item_code": "J",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-105; loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-105; loose rug",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-K",
          "item_code": "K",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-106; loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-106; loose rug",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-L",
          "item_code": "L",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Loose rugs; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LR-107; loose rug",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Loose rugs; including accessories and all ancillary works as necessary — Type LR-107; loose rug",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-M",
          "item_code": "M",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-101; sheer curtains",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-101; sheer curtains",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-N",
          "item_code": "N",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-102; plant pots",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-102; plant pots",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6127
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-P",
          "item_code": "P",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-103; lift lobby entrance",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-103; lift lobby entrance",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-Q",
          "item_code": "Q",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-104; artwork behind sofa",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-104; artwork behind sofa",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-R",
          "item_code": "R",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-105; artwork above console- hand painted art painting",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-105; artwork above console- hand painted art painting",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6133
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-S",
          "item_code": "S",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-106; artwork at table area",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-106; artwork at table area",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-T",
          "item_code": "T",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-107; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-107; artwork",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-U",
          "item_code": "U",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-108; entrance lobby corridor artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-108; entrance lobby corridor artwork",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-V",
          "item_code": "V",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-109; roller blinds",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-109; roller blinds",
          "quantity": 37,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/110-W",
          "item_code": "W",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-110; accessories",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-110; accessories",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/2",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/111",
      "section": "LOOSE FF&E",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/111-A",
          "item_code": "A",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-111; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-111; artwork",
          "quantity": 215,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "47",
            "Tower 2 [F]": "60",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "56",
            "TOTAL QTY [I]": "215",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-B",
          "item_code": "B",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-112; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-112; artwork",
          "quantity": 870,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "71",
            "Tower 1 [E]": "187",
            "Tower 2 [F]": "216",
            "Tower 3 [G]": "196",
            "Tower 4 [H]": "200",
            "TOTAL QTY [I]": "870",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-C",
          "item_code": "C",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-113; curtains manual",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-113; curtains manual",
          "quantity": 30,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-D",
          "item_code": "D",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-114; plant pots",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-114; plant pots",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-E",
          "item_code": "E",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-115; sheer curtains-seating area  and table area only (deleted)",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-115; sheer curtains-seating area  and table area only (deleted)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-F",
          "item_code": "F",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-116; plant pots",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-116; plant pots",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-G",
          "item_code": "G",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-117; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-117; artwork",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-H",
          "item_code": "H",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-118; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-118; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-J",
          "item_code": "J",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-119; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-119; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-K",
          "item_code": "K",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-120; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-120; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-L",
          "item_code": "L",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-121; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-121; artwork",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-M",
          "item_code": "M",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-122; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-122; artwork",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6177
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-N",
          "item_code": "N",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-123; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-123; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6179
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-P",
          "item_code": "P",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-124; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-124; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-Q",
          "item_code": "Q",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-125; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-125; artwork",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-R",
          "item_code": "R",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-126; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-126; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-S",
          "item_code": "S",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-127; printed artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-127; printed artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-T",
          "item_code": "T",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-128; printed artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-128; printed artwork",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-U",
          "item_code": "U",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-129; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-129; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-V",
          "item_code": "V",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-130; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-130; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-W",
          "item_code": "W",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-131; printed artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-131; printed artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-X",
          "item_code": "X",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-132; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-132; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-Y",
          "item_code": "Y",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-133; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-133; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/111-Z",
          "item_code": "Z",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-134; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-134; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/3",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/112",
      "section": "LOOSE FF&E",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/112-A",
          "item_code": "A",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-135; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-135; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-B",
          "item_code": "B",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-136; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-136; artwork",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-C",
          "item_code": "C",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-137; mirror",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-137; mirror",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-D",
          "item_code": "D",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Miscellaneous; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MI-138; artwork",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Miscellaneous; including accessories and all ancillary works as necessary — Type MI-138; artwork",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-E",
          "item_code": "E",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-101; sofa",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-101; sofa",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-F",
          "item_code": "F",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-102; armchair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-102; armchair",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-G",
          "item_code": "G",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-103; bench",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-103; bench",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-H",
          "item_code": "H",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-104; armchair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-104; armchair",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-J",
          "item_code": "J",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-105; dining chair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-105; dining chair",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-K",
          "item_code": "K",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-106; sofa",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-106; sofa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-L",
          "item_code": "L",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-107; lounge chair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-107; lounge chair",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-M",
          "item_code": "M",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-108; pouf-leather",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-108; pouf-leather",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-N",
          "item_code": "N",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-109; armchair-leather",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-109; armchair-leather",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-P",
          "item_code": "P",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-110; dining chair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-110; dining chair",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-Q",
          "item_code": "Q",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-111; bench  seat",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-111; bench  seat",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-R",
          "item_code": "R",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-112; ottoman",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-112; ottoman",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-S",
          "item_code": "S",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-113; armchair & pouf",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-113; armchair & pouf",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-T",
          "item_code": "T",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-114; sofa",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-114; sofa",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-U",
          "item_code": "U",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-115; armchair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-115; armchair",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/112-V",
          "item_code": "V",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-116; ottoman",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-116; ottoman",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/4",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6252
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/113",
      "section": "LOOSE FF&E",
      "sheet": "2 - Main",
      "source_collection_aed": 324125,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/113-A",
          "item_code": "A",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-117; armchair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-117; armchair",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-B",
          "item_code": "B",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-118; sofa in joinery",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-118; sofa in joinery",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-C",
          "item_code": "C",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-119; sofa in small seating",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-119; sofa in small seating",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-D",
          "item_code": "D",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-120; kids chair 1",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-120; kids chair 1",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-E",
          "item_code": "E",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-121; reception chair",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-121; reception chair",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-F",
          "item_code": "F",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Upholster goods; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Type SG-122; built in bench",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Upholster goods; including accessories and all ancillary works as necessary — Type SG-122; built in bench",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-G",
          "item_code": "G",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Ablution seats; including structure, finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 400 x 400 x 450mm high; to prayer room",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Ablution seats; including structure, finishes, fixings, accessories and all ancillary works as necessary — Size 400 x 400 x 450mm high; to prayer room",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1400,
          "amount_aed": 9800,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-H",
          "item_code": "H",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Chairs; to guard rooms",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Chairs; to guard rooms",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-J",
          "item_code": "J",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Chairs; to meeting room",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Chairs; to meeting room",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-K",
          "item_code": "K",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Chairs; to security manager room",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Chairs; to security manager room",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-L",
          "item_code": "L",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Chairs; to staff pantry",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Chairs; to staff pantry",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-M",
          "item_code": "M",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Table; size 900 x 900mm wide; to staff pantry",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Table; size 900 x 900mm wide; to staff pantry",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-N",
          "item_code": "N",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Table; size 1500 x 600mm wide; to security manager room",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Table; size 1500 x 600mm wide; to security manager room",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-P",
          "item_code": "P",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Table; size 3600 x 1500mm wide; to meeting room",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Table; size 3600 x 1500mm wide; to meeting room",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/113-Q",
          "item_code": "Q",
          "section": "LOOSE FF&E",
          "heading_path": [
            "Chairs and tables; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Loose furniture and Artworks - Supply and Installation by Others. Contractor to only allow for Co-ordination, attendance and builders work",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — LOOSE FF&E — Chairs and tables; including finishes, accessories and all ancillary works as necessary — Loose furniture and Artworks - Supply and Installation by Others. Contractor to only allow for Co-ordination, attendance and builders work",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 314325,
          "amount_aed": 314325,
          "amount_state": "number",
          "printed_page": "2/M/5",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6302
          },
          "extra_columns": {
            "TOTAL QTY [I]": "1",
            "GF & PODIUM [N]": "314,325.00"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/114",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/114-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Furnishings in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION M - FURNISHING (2/M) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Furnishings in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/M/6",
          "bill_ref": "2",
          "section_ref": "2/M",
          "source": {
            "sheet": "2 - Main",
            "row": 6323
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/115",
      "section": "LIFTS",
      "sheet": "2 - Main",
      "source_collection_aed": 425624,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/115-A",
          "item_code": "A",
          "section": "LIFTS",
          "heading_path": [
            "Lift Finishes",
            "Marble; laid on levelling screed; including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type ST-102; 20mm thick",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Lift Finishes — Marble; laid on levelling screed; including adhesive mortar, grout, joint and edge treatment sealer, accessories and all ancillary works as necessary — Type ST-102; 20mm thick",
          "quantity": 84,
          "unit": "m2",
          "rate_aed": 788,
          "amount_aed": 66192,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "21",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,548.00",
            "TOWER 2 [P]": "16,548.00",
            "TOWER 3 [Q]": "16,548.00",
            "TOWER 4 [R]": "16,548.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-B",
          "item_code": "B",
          "section": "LIFTS",
          "heading_path": [
            "Metal skirting; including adhesive, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-109; 100mm high",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Metal skirting; including adhesive, accessories and all ancillary works as necessary — Type MT-109; 100mm high",
          "quantity": 144,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "36",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "36",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,400.00",
            "TOWER 2 [P]": "5,400.00",
            "TOWER 3 [Q]": "5,400.00",
            "TOWER 4 [R]": "5,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-C",
          "item_code": "C",
          "section": "LIFTS",
          "heading_path": [
            "Metal insert; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-115; to floor fins",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Metal insert; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-115; to floor fins",
          "quantity": 160,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 19200,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6450
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "40",
            "Tower 3 [G]": "40",
            "Tower 4 [H]": "40",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "4,800.00",
            "TOWER 3 [Q]": "4,800.00",
            "TOWER 4 [R]": "4,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-D",
          "item_code": "D",
          "section": "LIFTS",
          "heading_path": [
            "Metal insert; including finishes, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-113; to wall fins",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Metal insert; including finishes, fixings, accessories and all ancillary works as necessary — Type MT-113; to wall fins",
          "quantity": 640,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6452
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "160",
            "Tower 2 [F]": "160",
            "Tower 3 [G]": "160",
            "Tower 4 [H]": "160",
            "TOTAL QTY [I]": "640",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "20,000.00",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "20,000.00",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-E",
          "item_code": "E",
          "section": "LIFTS",
          "heading_path": [
            "Grid ceiling; in metal finish; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type WD-102; with MT-109",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Grid ceiling; in metal finish; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Type WD-102; with MT-109",
          "quantity": 76,
          "unit": "m2",
          "rate_aed": 600,
          "amount_aed": 45600,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6456
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "19",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,400.00",
            "TOWER 2 [P]": "11,400.00",
            "TOWER 3 [Q]": "11,400.00",
            "TOWER 4 [R]": "11,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-F",
          "item_code": "F",
          "section": "LIFTS",
          "heading_path": [
            "Grid ceiling; in metal finish; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extra over for access panel; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Grid ceiling; in metal finish; including ceiling suspension system, shadows gaps, trims, corner protection profile, accessories and all ancillary works as necessary — Extra over for access panel; size 600 x 600mm",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6458
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "1,800.00",
            "TOWER 3 [Q]": "1,800.00",
            "TOWER 4 [R]": "1,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-G",
          "item_code": "G",
          "section": "LIFTS",
          "heading_path": [
            "Mirror; tinted mirror with frame; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type GL-108; 6mm thick",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Mirror; tinted mirror with frame; including, backing, supports, finishes, accessories and all ancillary works as necessary — Type GL-108; 6mm thick",
          "quantity": 168,
          "unit": "m2",
          "rate_aed": 675,
          "amount_aed": 113400,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6462
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "42",
            "Tower 2 [F]": "42",
            "Tower 3 [G]": "42",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "168",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,350.00",
            "TOWER 2 [P]": "28,350.00",
            "TOWER 3 [Q]": "28,350.00",
            "TOWER 4 [R]": "28,350.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/115-H",
          "item_code": "H",
          "section": "LIFTS",
          "heading_path": [
            "Wall cladding; in high pressure laminate finish; including, backing, supports, finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type LP-105; 20mm thick",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Wall cladding; in high pressure laminate finish; including, backing, supports, finishes, accessories and all ancillary works as necessary — Type LP-105; 20mm thick",
          "quantity": 144,
          "unit": "m2",
          "rate_aed": 503,
          "amount_aed": 72432,
          "amount_state": "number",
          "printed_page": "2/P/1",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6466
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "36",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "36",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,108.00",
            "TOWER 2 [P]": "18,108.00",
            "TOWER 3 [Q]": "18,108.00",
            "TOWER 4 [R]": "18,108.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/116",
      "section": "LIFTS",
      "sheet": "2 - Main",
      "source_collection_aed": 22441600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/116-A",
          "item_code": "A",
          "section": "LIFTS",
          "heading_path": [
            "Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-109",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type MT-109",
          "quantity": 92,
          "unit": "m2",
          "rate_aed": 1100,
          "amount_aed": 101200,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6488
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "23",
            "Tower 2 [F]": "23",
            "Tower 3 [G]": "23",
            "Tower 4 [H]": "23",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,300.00",
            "TOWER 2 [P]": "25,300.00",
            "TOWER 3 [Q]": "25,300.00",
            "TOWER 4 [R]": "25,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/116-B",
          "item_code": "B",
          "section": "LIFTS",
          "heading_path": [
            "Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Type MT-112",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Metal finish; including adhesive, finishes, brackets, fixings, accessories and all ancillary works as necessary — Type MT-112",
          "quantity": 64,
          "unit": "m2",
          "rate_aed": 1200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6490
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "16",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "19,200.00",
            "TOWER 2 [P]": "19,200.00",
            "TOWER 3 [Q]": "19,200.00",
            "TOWER 4 [R]": "19,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/116-C",
          "item_code": "C",
          "section": "LIFTS",
          "heading_path": [
            "Hand grab bar; in metal finish; fixed on bracket; including finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "1070mm length",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Hand grab bar; in metal finish; fixed on bracket; including finishes, brackets, fixings, accessories and all ancillary works as necessary — 1070mm length",
          "quantity": 48,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 40800,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6494
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,200.00",
            "TOWER 2 [P]": "10,200.00",
            "TOWER 3 [Q]": "10,200.00",
            "TOWER 4 [R]": "10,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/116-D",
          "item_code": "D",
          "section": "LIFTS",
          "heading_path": [
            "Hand grab bar; in metal finish; fixed on bracket; including finishes, brackets, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "1200mm length",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Hand grab bar; in metal finish; fixed on bracket; including finishes, brackets, fixings, accessories and all ancillary works as necessary — 1200mm length",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 950,
          "amount_aed": 22800,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6496
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,700.00",
            "TOWER 2 [P]": "5,700.00",
            "TOWER 3 [Q]": "5,700.00",
            "TOWER 4 [R]": "5,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/116-E",
          "item_code": "E",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 1"
          ],
          "own_description": "PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2700mm high, capacity 1600kgs (21 persons), speed 4.0m/s, 53 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 1 — PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2700mm high, capacity 1600kgs (21 persons), speed 4.0m/s, 53 total stops",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 7400000,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6502
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,400,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7400000"
          }
        },
        {
          "id": "2 - Main/116-F",
          "item_code": "F",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 1"
          ],
          "own_description": "PL03 & PL04;  cabin size 2000 x 1700 x 2700mm high, capacity 1600kgs (21 persons), speed 4.0m/s, 52 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 1 — PL03 & PL04;  cabin size 2000 x 1700 x 2700mm high, capacity 1600kgs (21 persons), speed 4.0m/s, 52 total stops",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 3700000,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6504
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,700,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3700000"
          }
        },
        {
          "id": "2 - Main/116-G",
          "item_code": "G",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 2"
          ],
          "own_description": "PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 61 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 2 — PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 61 total stops",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 7400000,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6508
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,400,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/116-H",
          "item_code": "H",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 2"
          ],
          "own_description": "PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 60 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 2 — PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 60 total stops",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 3700000,
          "amount_state": "number",
          "printed_page": "2/P/2",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6510
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,700,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/117",
      "section": "LIFTS",
      "sheet": "2 - Main",
      "source_collection_aed": 25900000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/117-A",
          "item_code": "A",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 3"
          ],
          "own_description": "PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 6.0m/s, 58 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 3 — PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 6.0m/s, 58 total stops",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 7400000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6529
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,400,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/117-B",
          "item_code": "B",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 3"
          ],
          "own_description": "PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 6.0m/s, 57 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 3 — PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 6.0m/s, 57 total stops",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 3700000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,700,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/117-C",
          "item_code": "C",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 4"
          ],
          "own_description": "PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 57 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 4 — PL01, PL02, PL05 & PL06;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 57 total stops",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 7400000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,400,000.00",
            "[S]": "TRUE",
            "[T]": "7400000"
          }
        },
        {
          "id": "2 - Main/117-D",
          "item_code": "D",
          "section": "LIFTS",
          "heading_path": [
            "Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary",
            "Tower 4"
          ],
          "own_description": "PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 56 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Passenger elevator; 6 car group car control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, two panel center opening door type, rails, 150mm wide steel separator beams, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weights, hauling, hoisting, brackets, fixings, accessories and all ancillary works as necessary — Tower 4 — PL03 & PL04;  cabin size 2000 x 1700 x 2600mm high, capacity 1600kgs (21 persons), speed 5.0m/s, 56 total stops",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 3700000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6537
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,700,000.00",
            "[S]": "TRUE",
            "[T]": "3700000"
          }
        },
        {
          "id": "2 - Main/117-E",
          "item_code": "E",
          "section": "LIFTS",
          "heading_path": [
            "Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary",
            "Tower 1"
          ],
          "own_description": "SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 53 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary — Tower 1 — SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 53 total stops",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 1850000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6543
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,850,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1850000"
          }
        },
        {
          "id": "2 - Main/117-F",
          "item_code": "F",
          "section": "LIFTS",
          "heading_path": [
            "Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary",
            "Tower 2"
          ],
          "own_description": "SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 61 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary — Tower 2 — SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 61 total stops",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 1850000,
          "amount_state": "number",
          "printed_page": "2/P/3",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,850,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/118",
      "section": "LIFTS",
      "sheet": "2 - Main",
      "source_collection_aed": 3700000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/118-A",
          "item_code": "A",
          "section": "LIFTS",
          "heading_path": [
            "Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary",
            "Tower 3"
          ],
          "own_description": "SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 57 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary — Tower 3 — SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 57 total stops",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 1850000,
          "amount_state": "number",
          "printed_page": "2/P/4",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6570
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,850,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/118-B",
          "item_code": "B",
          "section": "LIFTS",
          "heading_path": [
            "Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary",
            "Tower 4"
          ],
          "own_description": "SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 57 total stops",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — LIFTS — Service/fireman access elevator; simplex control operation, MRA-type; including elevator car, traction motor, wire ropes, door controls, door sensors, telescopic side opening (front opening) door type, rails, pit ladder, working platform, control panels, shaft & elevator car lighting fixtures, wirings, conduits, intercommunication system, counter weight, hauling, hoisting  and all ancillary works as necessary — Tower 4 — SL/FL1; cabin size 1400 x 2400 x 2800mm high, capacity 1600kgs (21 persons), speed 3.5m/s, 57 total stops",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1850000,
          "amount_aed": 1850000,
          "amount_state": "number",
          "printed_page": "2/P/4",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6574
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,850,000.00",
            "[S]": "TRUE",
            "[T]": "1850000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/119",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/119-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing shop drawings, as built drawings and material submittal approvals",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — SUNDRIES — Allow for providing shop drawings, as built drawings and material submittal approvals",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/5",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6623
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/119-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing catalogues, operation and maintenance manuals",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — SUNDRIES — Allow for providing catalogues, operation and maintenance manuals",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/5",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6625
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/119-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for labeling, tagging of equipment with their related control panel and components as specified",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — SUNDRIES — Allow for labeling, tagging of equipment with their related control panel and components as specified",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/5",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6627
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/119-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for testing and commissioning the complete installation",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — SUNDRIES — Allow for testing and commissioning the complete installation",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/5",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6629
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/120",
      "section": "BWIC",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/120-A",
          "item_code": "A",
          "section": "WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Allow for cutting or forming all holes, mortices, chases and the like and making good finishes for conveying systems",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC — Generally — Allow for cutting or forming all holes, mortices, chases and the like and making good finishes for conveying systems",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6679
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/120-B",
          "item_code": "B",
          "section": "WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Allow for fixing all sleeves, frames and built-in firestop system and making good finishes for conveying systems",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC — Generally — Allow for fixing all sleeves, frames and built-in firestop system and making good finishes for conveying systems",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6681
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/120-C",
          "item_code": "C",
          "section": "WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Allow for firestopping for all holes and making good finishes for conveying systems",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC — Generally — Allow for firestopping for all holes and making good finishes for conveying systems",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6683
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/120-D",
          "item_code": "D",
          "section": "WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Allow for building in or cutting and pinning brackets or the like and making good finishes for conveying systems",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC — Generally — Allow for building in or cutting and pinning brackets or the like and making good finishes for conveying systems",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6685
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/120-E",
          "item_code": "E",
          "section": "WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC",
          "heading_path": [
            "Generally"
          ],
          "own_description": "Allow connection to elevator monitoring system (EMS) at BMS room",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — WORK INCIDENTAL TO CONVEYING SYSTEM AND BWIC — Generally — Allow connection to elevator monitoring system (EMS) at BMS room",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6687
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/120-F",
          "item_code": "F",
          "section": "BWIC",
          "heading_path": [],
          "own_description": "Builders work in connection with conveying\r\nsystems",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — BWIC — Builders work in connection with conveying\r\nsystems",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/P/6",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6691
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/121",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/121-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Conveying Systems in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION P - CONVEYING SYSTEMS (2/P) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Conveying Systems in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/P/7",
          "bill_ref": "2",
          "section_ref": "2/P",
          "source": {
            "sheet": "2 - Main",
            "row": 6728
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/122",
      "section": "SANITARY FIXTURES & FITTINGS",
      "sheet": "2 - Main",
      "source_collection_aed": 1884867.45,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/122-A",
          "item_code": "A",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-204; sensor flush plate",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-204; sensor flush plate",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 270.65,
          "amount_aed": 8119.499999999999,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,119.50",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-B",
          "item_code": "B",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-205; urinal sensor flush plate",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-205; urinal sensor flush plate",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 3687.5,
          "amount_aed": 36875,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-C",
          "item_code": "C",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-206; concealed dual flush cistern for wall mounted WC",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-206; concealed dual flush cistern for wall mounted WC",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 556,
          "amount_aed": 16680,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-D",
          "item_code": "D",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-403; bottle trap",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-403; bottle trap",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 2728,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,728.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-E",
          "item_code": "E",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-406; single bowl sink bottle trap",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-406; single bowl sink bottle trap",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 440,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-F",
          "item_code": "F",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-506; kitchen mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-506; kitchen mixer",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 302.84,
          "amount_aed": 1514.1999999999998,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,514.20",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-G",
          "item_code": "G",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-509; shower column set",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-509; shower column set",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 1376,
          "amount_aed": 20640,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-H",
          "item_code": "H",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-513; sensor wash basin mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-513; sensor wash basin mixer",
          "quantity": 35,
          "unit": "Nr.",
          "rate_aed": 1456,
          "amount_aed": 50960,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-J",
          "item_code": "J",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-516; janitor mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-516; janitor mixer",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 432,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-K",
          "item_code": "K",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-601; floor drain and floor clean-out",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-601; floor drain and floor clean-out",
          "quantity": 51,
          "unit": "Nr.",
          "rate_aed": 160.93,
          "amount_aed": 8207.43,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,207.43",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-L",
          "item_code": "L",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-602; linear shower floor drain",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-602; linear shower floor drain",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 203.36,
          "amount_aed": 2440.32,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,440.32",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-M",
          "item_code": "M",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-751; flushing nozzle with flexible hose",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-751; flushing nozzle with flexible hose",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 1530,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,530.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-N",
          "item_code": "N",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-801; shattaf spray",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Type SAN-801; shattaf spray",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 708,
          "amount_aed": 21948,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,948.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-P",
          "item_code": "P",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Self closing pillar tap; to ablution",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Common Areas — Self closing pillar tap; to ablution",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6873
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-Q",
          "item_code": "Q",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-201; dual flush plate",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-201; dual flush plate",
          "quantity": 3227,
          "unit": "Nr.",
          "rate_aed": 495,
          "amount_aed": 1597365,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6877
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "772",
            "Tower 2 [F]": "805",
            "Tower 3 [G]": "782",
            "Tower 4 [H]": "770",
            "TOTAL QTY [I]": "3,227",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,510.00",
            "TOWER 1 [O]": "382,140.00",
            "TOWER 2 [P]": "398,475.00",
            "TOWER 3 [Q]": "387,090.00",
            "TOWER 4 [R]": "381,150.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/122-R",
          "item_code": "R",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-302; dual flush plate",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-302; dual flush plate",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 495,
          "amount_aed": 110880,
          "amount_state": "number",
          "printed_page": "2/Q/1",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,475.00",
            "TOWER 1 [O]": "22,770.00",
            "TOWER 2 [P]": "34,155.00",
            "TOWER 3 [Q]": "24,255.00",
            "TOWER 4 [R]": "27,225.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/123",
      "section": "SANITARY FIXTURES & FITTINGS",
      "sheet": "2 - Main",
      "source_collection_aed": 9367476.55,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/123-A",
          "item_code": "A",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-403; bottle trap",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-403; bottle trap",
          "quantity": 4208,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 370304,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "127",
            "Tower 1 [E]": "1,000",
            "Tower 2 [F]": "1,049",
            "Tower 3 [G]": "1,027",
            "Tower 4 [H]": "1,005",
            "TOTAL QTY [I]": "4,208",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,176.00",
            "TOWER 1 [O]": "88,000.00",
            "TOWER 2 [P]": "92,312.00",
            "TOWER 3 [Q]": "90,376.00",
            "TOWER 4 [R]": "88,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-B",
          "item_code": "B",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-501; single lever wash basin mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-501; single lever wash basin mixer",
          "quantity": 4207,
          "unit": "Nr.",
          "rate_aed": 333,
          "amount_aed": 1400931,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6899
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "127",
            "Tower 1 [E]": "999",
            "Tower 2 [F]": "1,049",
            "Tower 3 [G]": "1,027",
            "Tower 4 [H]": "1,005",
            "TOTAL QTY [I]": "4,207",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,291.00",
            "TOWER 1 [O]": "332,667.00",
            "TOWER 2 [P]": "349,317.00",
            "TOWER 3 [Q]": "341,991.00",
            "TOWER 4 [R]": "334,665.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-C",
          "item_code": "C",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-502; overhead shower",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-502; overhead shower",
          "quantity": 1583,
          "unit": "Nr.",
          "rate_aed": 378,
          "amount_aed": 598374,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6901
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "372",
            "Tower 3 [G]": "388",
            "Tower 4 [H]": "368",
            "TOTAL QTY [I]": "1,583",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "153,090.00",
            "TOWER 2 [P]": "140,616.00",
            "TOWER 3 [Q]": "146,664.00",
            "TOWER 4 [R]": "139,104.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-D",
          "item_code": "D",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-503; concealed shower mixer with hand shower",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-503; concealed shower mixer with hand shower",
          "quantity": 1583,
          "unit": "Nr.",
          "rate_aed": 805,
          "amount_aed": 1274315,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6903
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "372",
            "Tower 3 [G]": "388",
            "Tower 4 [H]": "368",
            "TOTAL QTY [I]": "1,583",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,250.00",
            "TOWER 1 [O]": "326,025.00",
            "TOWER 2 [P]": "299,460.00",
            "TOWER 3 [Q]": "312,340.00",
            "TOWER 4 [R]": "296,240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-E",
          "item_code": "E",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-504; bath spout and hand shower",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-504; bath spout and hand shower",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 870.49,
          "amount_aed": 3481.96,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "870.49",
            "TOWER 2 [P]": "870.49",
            "TOWER 3 [Q]": "870.49",
            "TOWER 4 [R]": "870.49",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-F",
          "item_code": "F",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-505; shower rail set",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-505; shower rail set",
          "quantity": 223,
          "unit": "Nr.",
          "rate_aed": 212.14,
          "amount_aed": 47307.219999999994,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "223",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,060.70",
            "TOWER 1 [O]": "9,546.30",
            "TOWER 2 [P]": "14,637.66",
            "TOWER 3 [Q]": "10,394.86",
            "TOWER 4 [R]": "11,667.70",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-G",
          "item_code": "G",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-506; kitchen mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-506; kitchen mixer",
          "quantity": 1553,
          "unit": "Nr.",
          "rate_aed": 302.84,
          "amount_aed": 470310.51999999996,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "404",
            "Tower 2 [F]": "353",
            "Tower 3 [G]": "387",
            "Tower 4 [H]": "359",
            "TOTAL QTY [I]": "1,553",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,142.00",
            "TOWER 1 [O]": "122,347.36",
            "TOWER 2 [P]": "106,902.52",
            "TOWER 3 [Q]": "117,199.08",
            "TOWER 4 [R]": "108,719.56",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-H",
          "item_code": "H",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-507; single lever wash basin mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-507; single lever wash basin mixer",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 303,
          "amount_aed": 67872,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,515.00",
            "TOWER 1 [O]": "13,938.00",
            "TOWER 2 [P]": "20,907.00",
            "TOWER 3 [Q]": "14,847.00",
            "TOWER 4 [R]": "16,665.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-J",
          "item_code": "J",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-508; floor standing bath mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-508; floor standing bath mixer",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 1441.06,
          "amount_aed": 40349.68,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6913
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "27,380.14",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,969.54",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-K",
          "item_code": "K",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-509; shower column set",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-509; shower column set",
          "quantity": 1028,
          "unit": "Nr.",
          "rate_aed": 1375.22,
          "amount_aed": 1413726.16,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "229",
            "Tower 2 [F]": "268",
            "Tower 3 [G]": "248",
            "Tower 4 [H]": "254",
            "TOTAL QTY [I]": "1,028",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,881.38",
            "TOWER 1 [O]": "314,925.38",
            "TOWER 2 [P]": "368,558.96",
            "TOWER 3 [Q]": "341,054.56",
            "TOWER 4 [R]": "349,305.88",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-L",
          "item_code": "L",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-511; shower mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-511; shower mixer",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 294.06,
          "amount_aed": 65869.44,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,470.30",
            "TOWER 1 [O]": "13,526.76",
            "TOWER 2 [P]": "20,290.14",
            "TOWER 3 [Q]": "14,408.94",
            "TOWER 4 [R]": "16,173.30",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-M",
          "item_code": "M",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-512; kitchen mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-512; kitchen mixer",
          "quantity": 58,
          "unit": "Nr.",
          "rate_aed": 302.84,
          "amount_aed": 17564.719999999998,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "908.52",
            "TOWER 2 [P]": "11,205.08",
            "TOWER 3 [Q]": "302.84",
            "TOWER 4 [R]": "5,148.28",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-N",
          "item_code": "N",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-517; deck mounted built in bathtub mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-517; deck mounted built in bathtub mixer",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 863.17,
          "amount_aed": 4315.849999999999,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,315.85",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-P",
          "item_code": "P",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-601; floor drain and floor clean-out",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-601; floor drain and floor clean-out",
          "quantity": 5671,
          "unit": "Nr.",
          "rate_aed": 135,
          "amount_aed": 765585,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6923
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "172",
            "Tower 1 [E]": "1,363",
            "Tower 2 [F]": "1,422",
            "Tower 3 [G]": "1,367",
            "Tower 4 [H]": "1,347",
            "TOTAL QTY [I]": "5,671",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,220.00",
            "TOWER 1 [O]": "184,005.00",
            "TOWER 2 [P]": "191,970.00",
            "TOWER 3 [Q]": "184,545.00",
            "TOWER 4 [R]": "181,845.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-Q",
          "item_code": "Q",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-602; shower floor drain",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-602; shower floor drain",
          "quantity": 2611,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 391650,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "79",
            "Tower 1 [E]": "634",
            "Tower 2 [F]": "640",
            "Tower 3 [G]": "636",
            "Tower 4 [H]": "622",
            "TOTAL QTY [I]": "2,611",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,850.00",
            "TOWER 1 [O]": "95,100.00",
            "TOWER 2 [P]": "96,000.00",
            "TOWER 3 [Q]": "95,400.00",
            "TOWER 4 [R]": "93,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/123-R",
          "item_code": "R",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-801; shattaf spray with integrated water supply valve",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fittings; fixed to tiled or plastered concrete or blockwork; including connections, supports, fixing, sealants, accessories and all ancillary works as necessary — Apartment Units — Type SAN-801; shattaf spray with integrated water supply valve",
          "quantity": 3440,
          "unit": "Nr.",
          "rate_aed": 708,
          "amount_aed": 2435520,
          "amount_state": "number",
          "printed_page": "2/Q/2",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "103",
            "Tower 1 [E]": "818",
            "Tower 2 [F]": "863",
            "Tower 3 [G]": "832",
            "Tower 4 [H]": "824",
            "TOTAL QTY [I]": "3,440",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "72,924.00",
            "TOWER 1 [O]": "579,144.00",
            "TOWER 2 [P]": "611,004.00",
            "TOWER 3 [Q]": "589,056.00",
            "TOWER 4 [R]": "583,392.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/124",
      "section": "SANITARY FIXTURES & FITTINGS",
      "sheet": "2 - Main",
      "source_collection_aed": 2048385.6500000001,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/124-A",
          "item_code": "A",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-101; wall mounted water closet",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-101; wall mounted water closet",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 614.46,
          "amount_aed": 18433.800000000003,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,433.80",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-B",
          "item_code": "B",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-111; floor mounted water closet with concealed cistern",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-111; floor mounted water closet with concealed cistern",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 614.46,
          "amount_aed": 2457.84,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,457.84",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-C",
          "item_code": "C",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-103; urinal",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-103; urinal",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 575,
          "amount_aed": 5750,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-D",
          "item_code": "D",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-104; medical water closet",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-104; medical water closet",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 614.46,
          "amount_aed": 3072.3,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,072.30",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-E",
          "item_code": "E",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-201; wall mounted urinal",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-201; wall mounted urinal",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 556,
          "amount_aed": 1112,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,112.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-F",
          "item_code": "F",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-206; wall mounted cistern",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-206; wall mounted cistern",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 556,
          "amount_aed": 17236,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,236.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-G",
          "item_code": "G",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-401; undercounter wash basin",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-401; undercounter wash basin",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 160.93,
          "amount_aed": 4988.83,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,988.83",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-H",
          "item_code": "H",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-404; kitchen sink",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-404; kitchen sink",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 505,
          "amount_aed": 2525,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,525.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-J",
          "item_code": "J",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-408; medical wash basin",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-408; medical wash basin",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 520,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-K",
          "item_code": "K",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-409; janitor sink",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-409; janitor sink",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 505,
          "amount_aed": 2525,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,525.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-L",
          "item_code": "L",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Type SAN-411; cleaner's sink with metal grating",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Type SAN-411; cleaner's sink with metal grating",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 664,
          "amount_aed": 664,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "664.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-M",
          "item_code": "M",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Under counter type wash basin",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Under counter type wash basin",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 160.93,
          "amount_aed": 643.72,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "643.72",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-N",
          "item_code": "N",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Full pedestal wash basin with level mixer",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Full pedestal wash basin with level mixer",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 785.8399999999999,
          "amount_aed": 785.8399999999999,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6982
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "785.84",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-P",
          "item_code": "P",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Common Areas"
          ],
          "own_description": "Pedestal type wash basin with single mixer, drain and bottle trap",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Common Areas — Pedestal type wash basin with single mixer, drain and bottle trap",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 965.8399999999999,
          "amount_aed": 3863.3599999999997,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6984
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,863.36",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/124-Q",
          "item_code": "Q",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-101; wall mounted water closet",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-101; wall mounted water closet",
          "quantity": 3226,
          "unit": "Nr.",
          "rate_aed": 614.46,
          "amount_aed": 1982247.9600000002,
          "amount_state": "number",
          "printed_page": "2/Q/3",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 6988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "772",
            "Tower 2 [F]": "804",
            "Tower 3 [G]": "783",
            "Tower 4 [H]": "769",
            "TOTAL QTY [I]": "3,226",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60,217.08",
            "TOWER 1 [O]": "474,363.12",
            "TOWER 2 [P]": "494,025.84",
            "TOWER 3 [Q]": "481,122.18",
            "TOWER 4 [R]": "472,519.74",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/125",
      "section": "SANITARY FIXTURES & FITTINGS",
      "sheet": "2 - Main",
      "source_collection_aed": 1884711.23,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/125-A",
          "item_code": "A",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-102; close-coupled water closet",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-102; close-coupled water closet",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 790.02,
          "amount_aed": 176964.47999999998,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,950.10",
            "TOWER 1 [O]": "36,340.92",
            "TOWER 2 [P]": "54,511.38",
            "TOWER 3 [Q]": "38,710.98",
            "TOWER 4 [R]": "43,451.10",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-B",
          "item_code": "B",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-301; freestanding bathtub 1800 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-301; freestanding bathtub 1800 x 800mm",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 1463,
          "amount_aed": 46816,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7010
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,463.00",
            "TOWER 2 [P]": "29,260.00",
            "TOWER 3 [Q]": "1,463.00",
            "TOWER 4 [R]": "14,630.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-C",
          "item_code": "C",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-303; built-in bathtub 1700 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-303; built-in bathtub 1700 x 700mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 826.6,
          "amount_aed": 4133,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7012
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,133.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-D",
          "item_code": "D",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-401; undercounter wash basin",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-401; undercounter wash basin",
          "quantity": 4207,
          "unit": "Nr.",
          "rate_aed": 160.93,
          "amount_aed": 677032.51,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7014
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "127",
            "Tower 1 [E]": "999",
            "Tower 2 [F]": "1,049",
            "Tower 3 [G]": "1,027",
            "Tower 4 [H]": "1,005",
            "TOTAL QTY [I]": "4,207",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,438.11",
            "TOWER 1 [O]": "160,769.07",
            "TOWER 2 [P]": "168,815.57",
            "TOWER 3 [Q]": "165,275.11",
            "TOWER 4 [R]": "161,734.65",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-E",
          "item_code": "E",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-402; wall mounted wash basin",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-402; wall mounted wash basin",
          "quantity": 224,
          "unit": "Nr.",
          "rate_aed": 237.01,
          "amount_aed": 53090.24,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7016
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,185.05",
            "TOWER 1 [O]": "10,902.46",
            "TOWER 2 [P]": "16,353.69",
            "TOWER 3 [Q]": "11,613.49",
            "TOWER 4 [R]": "13,035.55",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-F",
          "item_code": "F",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-404; kitchen sink",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-404; kitchen sink",
          "quantity": 1387,
          "unit": "Nr.",
          "rate_aed": 505,
          "amount_aed": 700435,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7018
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "45",
            "Tower 1 [E]": "362",
            "Tower 2 [F]": "321",
            "Tower 3 [G]": "338",
            "Tower 4 [H]": "321",
            "TOTAL QTY [I]": "1,387",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,725.00",
            "TOWER 1 [O]": "182,810.00",
            "TOWER 2 [P]": "162,105.00",
            "TOWER 3 [Q]": "170,690.00",
            "TOWER 4 [R]": "162,105.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-G",
          "item_code": "G",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Apartment Units"
          ],
          "own_description": "Type SAN-405; kitchen sink",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Apartment Units — Type SAN-405; kitchen sink",
          "quantity": 448,
          "unit": "Nr.",
          "rate_aed": 505,
          "amount_aed": 226240,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7020
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "138",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "110",
            "TOTAL QTY [I]": "448",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,050.00",
            "TOWER 1 [O]": "45,450.00",
            "TOWER 2 [P]": "69,690.00",
            "TOWER 3 [Q]": "50,500.00",
            "TOWER 4 [R]": "55,550.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/125-H",
          "item_code": "H",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7024
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/125-J",
          "item_code": "J",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for all identification including painting, marking and labelling",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for all identification including painting, marking and labelling",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7026
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/125-K",
          "item_code": "K",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7028
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/125-L",
          "item_code": "L",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7030
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/125-M",
          "item_code": "M",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for providing spares for the Mechanical Engineering Installation",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for providing spares for the Mechanical Engineering Installation",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "2/Q/4",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7032
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/126",
      "section": "SANITARY FIXTURES & FITTINGS",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/126-A",
          "item_code": "A",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary",
            "Sundries"
          ],
          "own_description": "Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Sanitary fixtures; fixed to tiled or plastered concrete or blockwork; including all waste and overflow outlets, connections, supports and sealing around with silicone-based sealants and all ancillary works as necessary — Sundries — Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7056
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-B",
          "item_code": "B",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7060
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-C",
          "item_code": "C",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7062
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-D",
          "item_code": "D",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7064
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-E",
          "item_code": "E",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7066
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-F",
          "item_code": "F",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7068
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-G",
          "item_code": "G",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7070
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/126-H",
          "item_code": "H",
          "section": "SANITARY FIXTURES & FITTINGS",
          "heading_path": [
            "Builders work in connection (BWIC) with Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SANITARY FIXTURES & FITTINGS — Builders work in connection (BWIC) with Mechanical Engineering Installations — Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/5",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7074
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/127",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 9485313.8,
      "section_notes": [
        "Note: Refer to the following:",
        "1. Drainage floor plan (Basement to Podium) Drawing Nr. ZD-3250587-CKR-DWG-PDM-PLD-5000 to 5996",
        "2. Drainage floor plan (Tower 1) Drawing Nr. ZD-3250587-CKR-DWG-TW1-PLD-5040 to 5330",
        "3. Drainage floor plan (Tower 2) Drawing Nr. ZD-3250587-CKR-DWG-TW2-PLD-5040 to 5610",
        "4. Drainage floor plan (Tower 3) Drawing Nr. ZD-3250587-CKR-DWG-TW3-PLD-5040 to 5570",
        "5. Drainage floor plan (Tower 4) Drawing Nr. ZD-3250587-CKR-DWG-TW4-PLD-5040 to 5570",
        "6. Drainage schematics Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD-5601 to 5610",
        "7. Drainage standard details and notes Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD-5502 and 5503",
        "8. MEP Specification Document Nr. ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/127-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 82mm diameter",
          "quantity": 6212.74,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 745528.7999999999,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7150
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "828",
            "Tower 1 [E]": "1,436",
            "Tower 2 [F]": "1,390",
            "Tower 3 [G]": "1,329",
            "Tower 4 [H]": "1,230",
            "TOTAL QTY [I]": "6,213",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "99,364.80",
            "TOWER 1 [O]": "172,320.00",
            "TOWER 2 [P]": "166,764.00",
            "TOWER 3 [Q]": "159,525.60",
            "TOWER 4 [R]": "147,554.40",
            "[S]": "TRUE",
            "[T]": "-24765.6"
          }
        },
        {
          "id": "2 - Main/127-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 110mm diameter",
          "quantity": 8217,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1314720,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7152
          },
          "extra_columns": {
            "Basement [C]": "1,201",
            "GF & Podium [D]": "3,831",
            "Tower 1 [E]": "1,993",
            "Tower 2 [F]": "426",
            "Tower 3 [G]": "406",
            "Tower 4 [H]": "360",
            "TOTAL QTY [I]": "8,217",
            "BASEMENTS [M]": "192,160.00",
            "GF & PODIUM [N]": "612,960.00",
            "TOWER 1 [O]": "318,880.00",
            "TOWER 2 [P]": "68,160.00",
            "TOWER 3 [Q]": "64,960.00",
            "TOWER 4 [R]": "57,600.00",
            "[S]": "TRUE",
            "[T]": "-261280"
          }
        },
        {
          "id": "2 - Main/127-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 160mm diameter",
          "quantity": 2030,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 426300,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7154
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "2,012",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,030",
            "BASEMENTS [M]": "3,780.00",
            "GF & PODIUM [N]": "422,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 200mm diameter",
          "quantity": 1789,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 465140,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7156
          },
          "extra_columns": {
            "Basement [C]": "278",
            "GF & Podium [D]": "1,511",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,789",
            "BASEMENTS [M]": "72,280.00",
            "GF & PODIUM [N]": "392,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 250mm diameter",
          "quantity": 189,
          "unit": "m",
          "rate_aed": 325,
          "amount_aed": 61425,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7158
          },
          "extra_columns": {
            "Basement [C]": "74",
            "GF & Podium [D]": "115",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "189",
            "BASEMENTS [M]": "24,050.00",
            "GF & PODIUM [N]": "37,375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 300mm diameter",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 10530,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7160
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "10,530.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "350mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 350mm diameter",
          "quantity": 207,
          "unit": "m",
          "rate_aed": 455,
          "amount_aed": 94185,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7162
          },
          "extra_columns": {
            "Basement [C]": "23",
            "GF & Podium [D]": "184",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "207",
            "BASEMENTS [M]": "10,465.00",
            "GF & PODIUM [N]": "83,720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "450mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water, parking and planter drainage pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 450mm diameter",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 585,
          "amount_aed": 65520,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7164
          },
          "extra_columns": {
            "Basement [C]": "112",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "65,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Below ground uPVC to BS EN 1401-1 pipes and fittings"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Below ground uPVC to BS EN 1401-1 pipes and fittings — 110mm diameter",
          "quantity": 626,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 37560,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7168
          },
          "extra_columns": {
            "Basement [C]": "626",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "626",
            "BASEMENTS [M]": "37,560.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Below ground uPVC to BS EN 1401-1 pipes and fittings"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Below ground uPVC to BS EN 1401-1 pipes and fittings — 160mm diameter",
          "quantity": 1562,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 140580,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7170
          },
          "extra_columns": {
            "Basement [C]": "1,562",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,562",
            "BASEMENTS [M]": "140,580.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 110mm diameter",
          "quantity": 13597,
          "unit": "m",
          "rate_aed": 320,
          "amount_aed": 4351040,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7174
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,506",
            "Tower 1 [E]": "2,742",
            "Tower 2 [F]": "3,074",
            "Tower 3 [G]": "2,767",
            "Tower 4 [H]": "3,508",
            "TOTAL QTY [I]": "13,597",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "481,920.00",
            "TOWER 1 [O]": "877,440.00",
            "TOWER 2 [P]": "983,680.00",
            "TOWER 3 [Q]": "885,440.00",
            "TOWER 4 [R]": "1,122,560.00",
            "[S]": "TRUE",
            "[T]": "245120"
          }
        },
        {
          "id": "2 - Main/127-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 160mm diameter",
          "quantity": 1499,
          "unit": "m",
          "rate_aed": 465,
          "amount_aed": 697035,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7176
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,499",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,499",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "697,035.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 200mm diameter",
          "quantity": 1055,
          "unit": "m",
          "rate_aed": 580,
          "amount_aed": 611900,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7178
          },
          "extra_columns": {
            "Basement [C]": "114",
            "GF & Podium [D]": "941",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,055",
            "BASEMENTS [M]": "66,120.00",
            "GF & PODIUM [N]": "545,780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 250mm diameter",
          "quantity": 115,
          "unit": "m",
          "rate_aed": 725,
          "amount_aed": 83375,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7180
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "115",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "115",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "83,375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "350mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 350mm diameter",
          "quantity": 207,
          "unit": "m",
          "rate_aed": 1015,
          "amount_aed": 210105,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7182
          },
          "extra_columns": {
            "Basement [C]": "23",
            "GF & Podium [D]": "184",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "207",
            "BASEMENTS [M]": "23,345.00",
            "GF & PODIUM [N]": "186,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-R",
          "item_code": "R",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Above ground HDPE SDR26"
          ],
          "own_description": "450mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Above ground HDPE SDR26 — 450mm diameter",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 1305,
          "amount_aed": 146160,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7184
          },
          "extra_columns": {
            "Basement [C]": "112",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "146,160.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-S",
          "item_code": "S",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Stormwater transfer pipes and fittings; uPVC class E"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Stormwater transfer pipes and fittings; uPVC class E — 100mm diameter",
          "quantity": 6,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7188
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/127-T",
          "item_code": "T",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Stormwater transfer pipes and fittings; uPVC class E"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Stormwater transfer pipes and fittings; uPVC class E — 125mm diameter",
          "quantity": 318,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 23850,
          "amount_state": "number",
          "printed_page": "2/Q/7",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7190
          },
          "extra_columns": {
            "Basement [C]": "318",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "318",
            "BASEMENTS [M]": "23,850.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/128",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2260215.4,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/128-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Stormwater transfer pipes and fittings; uPVC class E"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Stormwater transfer pipes and fittings; uPVC class E — 150mm diameter",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 765,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7208
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "765.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 82mm diameter",
          "quantity": 4779.02,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 573482.4,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "362",
            "Tower 1 [E]": "1,262",
            "Tower 2 [F]": "1,025",
            "Tower 3 [G]": "1,116",
            "Tower 4 [H]": "1,014",
            "TOTAL QTY [I]": "4,779",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,440.00",
            "TOWER 1 [O]": "151,440.00",
            "TOWER 2 [P]": "123,000.00",
            "TOWER 3 [Q]": "133,922.40",
            "TOWER 4 [R]": "121,680.00",
            "[S]": "TRUE",
            "[T]": "-29760"
          }
        },
        {
          "id": "2 - Main/128-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 110mm diameter",
          "quantity": 357,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 53550,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "253",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "30",
            "Tower 3 [G]": "48",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "357",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,950.00",
            "TOWER 1 [O]": "3,900.00",
            "TOWER 2 [P]": "4,500.00",
            "TOWER 3 [Q]": "7,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3900"
          }
        },
        {
          "id": "2 - Main/128-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 160mm diameter",
          "quantity": 772,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 162120,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "772",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "772",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "162,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 200mm diameter",
          "quantity": 76,
          "unit": "m",
          "rate_aed": 263,
          "amount_aed": 19988,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "76",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,988.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Rain water outlet (RWO); size 110mm diameter dome type",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Rain water outlet (RWO); size 110mm diameter dome type",
          "quantity": 52,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 26000,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Roof rain water outlet; size 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Roof rain water outlet; size 110mm diameter",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,000.00",
            "TOWER 2 [P]": "1,000.00",
            "TOWER 3 [Q]": "1,000.00",
            "TOWER 4 [R]": "1,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Parking drain (PD); size 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Parking drain (PD); size 110mm diameter",
          "quantity": 218,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 54500,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7226
          },
          "extra_columns": {
            "Basement [C]": "95",
            "GF & Podium [D]": "123",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "218",
            "BASEMENTS [M]": "23,750.00",
            "GF & PODIUM [N]": "30,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Balcony drain; stainless steel SS 304 cover, size 82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Balcony drain; stainless steel SS 304 cover, size 82mm diameter",
          "quantity": 3398,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 1189300,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "190",
            "Tower 1 [E]": "761",
            "Tower 2 [F]": "805",
            "Tower 3 [G]": "860",
            "Tower 4 [H]": "782",
            "TOTAL QTY [I]": "3,398",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "66,500.00",
            "TOWER 1 [O]": "266,350.00",
            "TOWER 2 [P]": "281,750.00",
            "TOWER 3 [Q]": "301,000.00",
            "TOWER 4 [R]": "273,700.00",
            "[S]": "TRUE",
            "[T]": "7350"
          }
        },
        {
          "id": "2 - Main/128-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Planter drain; size 82 mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Planter drain; size 82 mm diameter",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 12600,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,700.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "2,700.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE",
            "[T]": "900"
          }
        },
        {
          "id": "2 - Main/128-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Planter drain; size 110 mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Planter drain; size 110 mm diameter",
          "quantity": 274,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 137000,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "274",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "274",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "137,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "U-trap; size 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — U-trap; size 110mm diameter",
          "quantity": 36,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "U-trap; size 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — U-trap; size 160mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 1050,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Clean out; 110mm diameter",
          "quantity": 302,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 10570,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "302",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "302",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,570.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Clean out; 160mm diameter",
          "quantity": 157,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 7850,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "157",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "157",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/128-R",
          "item_code": "R",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Clean out; 200mm diameter",
          "quantity": 88,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 5280,
          "amount_state": "number",
          "printed_page": "2/Q/8",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "88",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "88",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/129",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1416861,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/129-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Clean out; 250mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 560,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7260
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, brackets, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 350mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Accessories; including fixings, brackets, supports and all ancillary works as necessary — Clean out; 350mm diameter",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 112,
          "amount_aed": 1456,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7262
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,456.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete"
          ],
          "own_description": "Floor clean out (FCO); 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete — Floor clean out (FCO); 110mm diameter",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 315,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7266
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "315.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Car park catch basin; including HDDI grating, uPVC round body, GRP perforated basket, fixings; complete"
          ],
          "own_description": "Car park catch basin (CB); 300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Car park catch basin; including HDDI grating, uPVC round body, GRP perforated basket, fixings; complete — Car park catch basin (CB); 300 x 300mm",
          "quantity": 98,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 294000,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7270
          },
          "extra_columns": {
            "Basement [C]": "98",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "294,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Rain water free discharge with stainless steel hinged flapper"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Rain water free discharge with stainless steel hinged flapper — 110mm diameter",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 6500,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7274
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,500.00",
            "TOWER 1 [O]": "1,000.00",
            "TOWER 2 [P]": "1,000.00",
            "TOWER 3 [Q]": "1,000.00",
            "TOWER 4 [R]": "1,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including VFD, valves, header lines, vibration isolators, controls, wiring, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Floor standing stormwater transfer pump"
          ],
          "own_description": "T2-B2-STP; 2 duty + 1 standby with flow rate of 7.5L/s and pump head of 30m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including VFD, valves, header lines, vibration isolators, controls, wiring, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Floor standing stormwater transfer pump — T2-B2-STP; 2 duty + 1 standby with flow rate of 7.5L/s and pump head of 30m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 30000,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7280
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "30,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including VFD, valves, header lines, vibration isolators, controls, wiring, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Floor standing stormwater transfer pump"
          ],
          "own_description": "T4-B2-STP; 2 duty + 1 standby with flow rate of 7.5L/s and pump head of 25m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including VFD, valves, header lines, vibration isolators, controls, wiring, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Floor standing stormwater transfer pump — T4-B2-STP; 2 duty + 1 standby with flow rate of 7.5L/s and pump head of 25m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7282
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "35,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/129-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 25mm diameter",
          "quantity": 1652,
          "unit": "m",
          "rate_aed": 40,
          "amount_aed": 66080,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "862",
            "Tower 2 [F]": "366",
            "Tower 3 [G]": "69",
            "Tower 4 [H]": "355",
            "TOTAL QTY [I]": "1,652",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "34,480.00",
            "TOWER 2 [P]": "14,640.00",
            "TOWER 3 [Q]": "2,760.00",
            "TOWER 4 [R]": "14,200.00",
            "[S]": "TRUE",
            "[T]": "-20280"
          }
        },
        {
          "id": "2 - Main/129-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 32mm diameter",
          "quantity": 19659,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 982950,
          "amount_state": "number",
          "printed_page": "2/Q/9",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "981",
            "Tower 1 [E]": "4,175",
            "Tower 2 [F]": "5,003",
            "Tower 3 [G]": "5,078",
            "Tower 4 [H]": "4,422",
            "TOTAL QTY [I]": "19,659",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,050.00",
            "TOWER 1 [O]": "208,750.00",
            "TOWER 2 [P]": "250,150.00",
            "TOWER 3 [Q]": "253,900.00",
            "TOWER 4 [R]": "221,100.00",
            "[S]": "TRUE",
            "[T]": "12350"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/130",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1319696,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/130-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 40mm diameter",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 4140,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "33",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "780.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "180.00",
            "TOWER 4 [R]": "1,980.00",
            "[S]": "TRUE",
            "[T]": "1200"
          }
        },
        {
          "id": "2 - Main/130-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 50mm diameter",
          "quantity": 108,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 7560,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "32",
            "Tower 2 [F]": "26",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "108",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "2,240.00",
            "TOWER 2 [P]": "1,820.00",
            "TOWER 3 [Q]": "700.00",
            "TOWER 4 [R]": "1,260.00",
            "[S]": "TRUE",
            "[T]": "-980"
          }
        },
        {
          "id": "2 - Main/130-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 82mm diameter",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 9500,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "93",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,300.00",
            "TOWER 1 [O]": "200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-200"
          }
        },
        {
          "id": "2 - Main/130-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 110mm diameter",
          "quantity": 1085,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 141050,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7315
          },
          "extra_columns": {
            "Basement [C]": "158",
            "GF & Podium [D]": "188",
            "Tower 1 [E]": "169",
            "Tower 2 [F]": "202",
            "Tower 3 [G]": "183",
            "Tower 4 [H]": "185",
            "TOTAL QTY [I]": "1,085",
            "BASEMENTS [M]": "20,540.00",
            "GF & PODIUM [N]": "24,440.00",
            "TOWER 1 [O]": "21,970.00",
            "TOWER 2 [P]": "26,260.00",
            "TOWER 3 [Q]": "23,790.00",
            "TOWER 4 [R]": "24,050.00",
            "[S]": "TRUE",
            "[T]": "2080"
          }
        },
        {
          "id": "2 - Main/130-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC class D pipes and fittings"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Condensate drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC class D pipes and fittings — 160mm diameter",
          "quantity": 344,
          "unit": "m",
          "rate_aed": 190,
          "amount_aed": 65360,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "344",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "344",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/130-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 25mm diameter",
          "quantity": 1652,
          "unit": "m",
          "rate_aed": 35,
          "amount_aed": 57820,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "862",
            "Tower 2 [F]": "366",
            "Tower 3 [G]": "69",
            "Tower 4 [H]": "355",
            "TOTAL QTY [I]": "1,652",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "30,170.00",
            "TOWER 2 [P]": "12,810.00",
            "TOWER 3 [Q]": "2,415.00",
            "TOWER 4 [R]": "12,425.00",
            "[S]": "TRUE",
            "[T]": "-17745"
          }
        },
        {
          "id": "2 - Main/130-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 32mm diameter",
          "quantity": 19659,
          "unit": "m",
          "rate_aed": 40,
          "amount_aed": 786360,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "981",
            "Tower 1 [E]": "4,175",
            "Tower 2 [F]": "5,003",
            "Tower 3 [G]": "5,078",
            "Tower 4 [H]": "4,422",
            "TOTAL QTY [I]": "19,659",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,240.00",
            "TOWER 1 [O]": "167,000.00",
            "TOWER 2 [P]": "200,120.00",
            "TOWER 3 [Q]": "203,120.00",
            "TOWER 4 [R]": "176,880.00",
            "[S]": "TRUE",
            "[T]": "9880"
          }
        },
        {
          "id": "2 - Main/130-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 40mm diameter",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 4140,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "33",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "780.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "180.00",
            "TOWER 4 [R]": "1,980.00",
            "[S]": "TRUE",
            "[T]": "1200"
          }
        },
        {
          "id": "2 - Main/130-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 50mm diameter",
          "quantity": 108,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 7560,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "32",
            "Tower 2 [F]": "26",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "108",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "2,240.00",
            "TOWER 2 [P]": "1,820.00",
            "TOWER 3 [Q]": "700.00",
            "TOWER 4 [R]": "1,260.00",
            "[S]": "TRUE",
            "[T]": "-980"
          }
        },
        {
          "id": "2 - Main/130-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 82mm diameter",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 8550,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "93",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,370.00",
            "TOWER 1 [O]": "180.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-180"
          }
        },
        {
          "id": "2 - Main/130-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 110mm diameter",
          "quantity": 1085,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 119350,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7331
          },
          "extra_columns": {
            "Basement [C]": "158",
            "GF & Podium [D]": "188",
            "Tower 1 [E]": "169",
            "Tower 2 [F]": "202",
            "Tower 3 [G]": "183",
            "Tower 4 [H]": "185",
            "TOTAL QTY [I]": "1,085",
            "BASEMENTS [M]": "17,380.00",
            "GF & PODIUM [N]": "20,680.00",
            "TOWER 1 [O]": "18,590.00",
            "TOWER 2 [P]": "22,220.00",
            "TOWER 3 [Q]": "20,130.00",
            "TOWER 4 [R]": "20,350.00",
            "[S]": "TRUE",
            "[T]": "1760"
          }
        },
        {
          "id": "2 - Main/130-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Closed cell elastomeric foam sheet, 13mm thick"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Closed cell elastomeric foam sheet, 13mm thick — 160mm diameter",
          "quantity": 344,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 55040,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "344",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "344",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "55,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/130-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "UV resistant insulation, 25mm thick with 0.6mm aluminum cladding plain sheet"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — UV resistant insulation, 25mm thick with 0.6mm aluminum cladding plain sheet — 50mm diameter",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 140,
          "amount_aed": 5880,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "7",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,100.00",
            "TOWER 2 [P]": "980.00",
            "TOWER 3 [Q]": "1,820.00",
            "TOWER 4 [R]": "980.00",
            "[S]": "TRUE",
            "[T]": "-1120"
          }
        },
        {
          "id": "2 - Main/130-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Vent drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Below ground uPVC to BS EN 1401-1 pipes and fittings"
          ],
          "own_description": "'82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Vent drain pipe installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Below ground uPVC to BS EN 1401-1 pipes and fittings — '82mm diameter",
          "quantity": 502,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 45180,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7343
          },
          "extra_columns": {
            "Basement [C]": "502",
            "TOTAL QTY [I]": "502",
            "BASEMENTS [M]": "45,180.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/130-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 32mm diameter",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 25,
          "amount_aed": 1250,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/130-R",
          "item_code": "R",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 50mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 27,
          "amount_aed": 81,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7349
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "81.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/130-S",
          "item_code": "S",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 82mm diameter",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 30,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7351
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/130-T",
          "item_code": "T",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 110mm diameter",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 455,
          "amount_state": "number",
          "printed_page": "2/Q/10",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7353
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "455.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/131",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 17135700,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/131-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 160mm diameter",
          "quantity": 75,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 3750,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7365
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Funnel floor drain; including nickel bronze funnel with floor grating"
          ],
          "own_description": "Funnel floor Drain (FUD); 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Funnel floor drain; including nickel bronze funnel with floor grating — Funnel floor Drain (FUD); 50mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 8100,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7369
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,050.00",
            "TOWER 1 [O]": "2,700.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,350.00",
            "[S]": "TRUE",
            "[T]": "-1350"
          }
        },
        {
          "id": "2 - Main/131-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Funnel floor drain; including nickel bronze funnel with floor grating"
          ],
          "own_description": "Funnel floor Drain (FUD); 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Funnel floor drain; including nickel bronze funnel with floor grating — Funnel floor Drain (FUD); 110mm diameter",
          "quantity": 22,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7371
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,000.00",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "9,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 32mm diameter",
          "quantity": 7604,
          "unit": "m",
          "rate_aed": 55,
          "amount_aed": 418220,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "356",
            "Tower 1 [E]": "1,803",
            "Tower 2 [F]": "1,781",
            "Tower 3 [G]": "1,883",
            "Tower 4 [H]": "1,781",
            "TOTAL QTY [I]": "7,604",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,580.00",
            "TOWER 1 [O]": "99,165.00",
            "TOWER 2 [P]": "97,955.00",
            "TOWER 3 [Q]": "103,565.00",
            "TOWER 4 [R]": "97,955.00",
            "[S]": "TRUE",
            "[T]": "-1210"
          }
        },
        {
          "id": "2 - Main/131-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 40mm diameter",
          "quantity": 20607,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1236420,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,310",
            "Tower 1 [E]": "4,073",
            "Tower 2 [F]": "5,369",
            "Tower 3 [G]": "5,137",
            "Tower 4 [H]": "4,718",
            "TOTAL QTY [I]": "20,607",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "78,600.00",
            "TOWER 1 [O]": "244,380.00",
            "TOWER 2 [P]": "322,140.00",
            "TOWER 3 [Q]": "308,220.00",
            "TOWER 4 [R]": "283,080.00",
            "[S]": "TRUE",
            "[T]": "38700"
          }
        },
        {
          "id": "2 - Main/131-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 50mm diameter",
          "quantity": 2546,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 190950,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "725",
            "Tower 2 [F]": "537",
            "Tower 3 [G]": "626",
            "Tower 4 [H]": "545",
            "TOTAL QTY [I]": "2,546",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,475.00",
            "TOWER 1 [O]": "54,375.00",
            "TOWER 2 [P]": "40,275.00",
            "TOWER 3 [Q]": "46,950.00",
            "TOWER 4 [R]": "40,875.00",
            "[S]": "TRUE",
            "[T]": "-13500"
          }
        },
        {
          "id": "2 - Main/131-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 82mm diameter",
          "quantity": 10169,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 1220280,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "965",
            "Tower 1 [E]": "2,101",
            "Tower 2 [F]": "2,508",
            "Tower 3 [G]": "2,332",
            "Tower 4 [H]": "2,263",
            "TOTAL QTY [I]": "10,169",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "115,800.00",
            "TOWER 1 [O]": "252,120.00",
            "TOWER 2 [P]": "300,960.00",
            "TOWER 3 [Q]": "279,840.00",
            "TOWER 4 [R]": "271,560.00",
            "[S]": "TRUE",
            "[T]": "19440"
          }
        },
        {
          "id": "2 - Main/131-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 110mm diameter",
          "quantity": 41648,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 6663680,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7385
          },
          "extra_columns": {
            "Basement [C]": "82",
            "GF & Podium [D]": "4,175",
            "Tower 1 [E]": "8,749",
            "Tower 2 [F]": "10,066",
            "Tower 3 [G]": "9,477",
            "Tower 4 [H]": "9,099",
            "TOTAL QTY [I]": "41,648",
            "BASEMENTS [M]": "13,120.00",
            "GF & PODIUM [N]": "668,000.00",
            "TOWER 1 [O]": "1,399,840.00",
            "TOWER 2 [P]": "1,610,560.00",
            "TOWER 3 [Q]": "1,516,320.00",
            "TOWER 4 [R]": "1,455,840.00",
            "[S]": "TRUE",
            "[T]": "56000"
          }
        },
        {
          "id": "2 - Main/131-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 160mm diameter",
          "quantity": 30592,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 6424320,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7387
          },
          "extra_columns": {
            "Basement [C]": "21",
            "GF & Podium [D]": "3,374",
            "Tower 1 [E]": "6,164",
            "Tower 2 [F]": "7,631",
            "Tower 3 [G]": "6,855",
            "Tower 4 [H]": "6,547",
            "TOTAL QTY [I]": "30,592",
            "BASEMENTS [M]": "4,410.00",
            "GF & PODIUM [N]": "708,540.00",
            "TOWER 1 [O]": "1,294,440.00",
            "TOWER 2 [P]": "1,602,510.00",
            "TOWER 3 [Q]": "1,439,550.00",
            "TOWER 4 [R]": "1,374,870.00",
            "[S]": "TRUE",
            "[T]": "80430"
          }
        },
        {
          "id": "2 - Main/131-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 200mm diameter",
          "quantity": 1807,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 469820,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,807",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,807",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "469,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 250mm diameter",
          "quantity": 566,
          "unit": "m",
          "rate_aed": 325,
          "amount_aed": 183950,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "566",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "566",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "183,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary",
            "Above ground uPVC to BS EN 1566-1 pipes and fittings"
          ],
          "own_description": "300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Waste water, soil, vent, kitchen pipes installation; including fittings, hangers, supports, fixings and all ancillary works as necessary — Above ground uPVC to BS EN 1566-1 pipes and fittings — 300mm diameter",
          "quantity": 201,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 78390,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "201",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "201",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "78,390.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Discharge pressure pipes; uPVC class E"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Discharge pressure pipes; uPVC class E — 50mm diameter",
          "quantity": 1029,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 72030,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7397
          },
          "extra_columns": {
            "Basement [C]": "1,029",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,029",
            "BASEMENTS [M]": "72,030.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Discharge pressure pipes; uPVC class E"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Discharge pressure pipes; uPVC class E — 82mm diameter",
          "quantity": 1374,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 116790,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7399
          },
          "extra_columns": {
            "Basement [C]": "1,371",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,374",
            "BASEMENTS [M]": "116,535.00",
            "GF & PODIUM [N]": "255.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/131-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Discharge pressure pipes; uPVC class E"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Discharge pressure pipes; uPVC class E — 100mm diameter",
          "quantity": 160,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 16000,
          "amount_state": "number",
          "printed_page": "2/Q/11",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7401
          },
          "extra_columns": {
            "Basement [C]": "159",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "15,900.00",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/132",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 4801993,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/132-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Discharge pressure pipes; uPVC class E"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Discharge pressure pipes; uPVC class E — 150mm diameter",
          "quantity": 278,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 41700,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7421
          },
          "extra_columns": {
            "Basement [C]": "278",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "278",
            "BASEMENTS [M]": "41,700.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Discharge pressure pipes; uPVC class E"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Discharge pressure pipes; uPVC class E — 200mm diameter",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7423
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "1,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 32mm diameter",
          "quantity": 4382,
          "unit": "m",
          "rate_aed": 40,
          "amount_aed": 175280,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "169",
            "Tower 1 [E]": "1,071",
            "Tower 2 [F]": "1,028",
            "Tower 3 [G]": "1,069",
            "Tower 4 [H]": "1,045",
            "TOTAL QTY [I]": "4,382",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,760.00",
            "TOWER 1 [O]": "42,840.00",
            "TOWER 2 [P]": "41,120.00",
            "TOWER 3 [Q]": "42,760.00",
            "TOWER 4 [R]": "41,800.00",
            "[S]": "TRUE",
            "[T]": "-1040"
          }
        },
        {
          "id": "2 - Main/132-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 40mm diameter",
          "quantity": 14174,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 708700,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "827",
            "Tower 1 [E]": "2,924",
            "Tower 2 [F]": "3,645",
            "Tower 3 [G]": "3,502",
            "Tower 4 [H]": "3,276",
            "TOTAL QTY [I]": "14,174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "41,350.00",
            "TOWER 1 [O]": "146,200.00",
            "TOWER 2 [P]": "182,250.00",
            "TOWER 3 [Q]": "175,100.00",
            "TOWER 4 [R]": "163,800.00",
            "[S]": "TRUE",
            "[T]": "17600"
          }
        },
        {
          "id": "2 - Main/132-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 50mm diameter",
          "quantity": 2452,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 147120,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "688",
            "Tower 2 [F]": "525",
            "Tower 3 [G]": "593",
            "Tower 4 [H]": "533",
            "TOTAL QTY [I]": "2,452",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,780.00",
            "TOWER 1 [O]": "41,280.00",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "35,580.00",
            "TOWER 4 [R]": "31,980.00",
            "[S]": "TRUE",
            "[T]": "-9300"
          }
        },
        {
          "id": "2 - Main/132-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 82mm diameter",
          "quantity": 9804,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 882360,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "690",
            "Tower 1 [E]": "2,096",
            "Tower 2 [F]": "2,498",
            "Tower 3 [G]": "2,333",
            "Tower 4 [H]": "2,187",
            "TOTAL QTY [I]": "9,804",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "62,100.00",
            "TOWER 1 [O]": "188,640.00",
            "TOWER 2 [P]": "224,820.00",
            "TOWER 3 [Q]": "209,970.00",
            "TOWER 4 [R]": "196,830.00",
            "[S]": "TRUE",
            "[T]": "8190"
          }
        },
        {
          "id": "2 - Main/132-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 110mm diameter",
          "quantity": 22873,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 2287300,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,442",
            "Tower 1 [E]": "4,778",
            "Tower 2 [F]": "5,544",
            "Tower 3 [G]": "5,199",
            "Tower 4 [H]": "4,910",
            "TOTAL QTY [I]": "22,873",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "244,200.00",
            "TOWER 1 [O]": "477,800.00",
            "TOWER 2 [P]": "554,400.00",
            "TOWER 3 [Q]": "519,900.00",
            "TOWER 4 [R]": "491,000.00",
            "[S]": "TRUE",
            "[T]": "13200"
          }
        },
        {
          "id": "2 - Main/132-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 160mm diameter",
          "quantity": 2137,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 267125,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,803",
            "Tower 1 [E]": "97",
            "Tower 2 [F]": "93",
            "Tower 3 [G]": "87",
            "Tower 4 [H]": "57",
            "TOTAL QTY [I]": "2,137",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "225,375.00",
            "TOWER 1 [O]": "12,125.00",
            "TOWER 2 [P]": "11,625.00",
            "TOWER 3 [Q]": "10,875.00",
            "TOWER 4 [R]": "7,125.00",
            "[S]": "TRUE",
            "[T]": "-5000"
          }
        },
        {
          "id": "2 - Main/132-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Acoustic lagging insulation, 2mm thick barium sulphate loaded limp vinyl sheet with 25mm thick foil faced rockwool/fiberglass insulation and retention straps for rainwater and balcony drain pipes and all ancillary works as necessary — 200mm diameter",
          "quantity": 1335,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 213600,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,335",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,335",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "213,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 50mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7443
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "1,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 82mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 980,
          "amount_aed": 5880,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7445
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "5,880.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 100mm diameter",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 20400,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7447
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "7,200.00",
            "TOWER 2 [P]": "9,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7200"
          }
        },
        {
          "id": "2 - Main/132-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 160mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1933,
          "amount_aed": 7732,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7449
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,732.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 200mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2422,
          "amount_aed": 9688,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7451
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,688.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 250mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3033,
          "amount_aed": 12132,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7453
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,132.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-R",
          "item_code": "R",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Isolation valve; 300mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3644,
          "amount_aed": 14576,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7455
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,576.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/132-S",
          "item_code": "S",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "U-trap; size 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — U-trap; size 110mm diameter",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "2/Q/12",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7457
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/133",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1214678,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/133-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "U-trap; size 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — U-trap; size 160mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 32mm diameter",
          "quantity": 2504,
          "unit": "Nr.",
          "rate_aed": 25,
          "amount_aed": 62600,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "587",
            "Tower 2 [F]": "597",
            "Tower 3 [G]": "658",
            "Tower 4 [H]": "588",
            "TOTAL QTY [I]": "2,504",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,850.00",
            "TOWER 1 [O]": "14,675.00",
            "TOWER 2 [P]": "14,925.00",
            "TOWER 3 [Q]": "16,450.00",
            "TOWER 4 [R]": "14,700.00",
            "[S]": "TRUE",
            "[T]": "25"
          }
        },
        {
          "id": "2 - Main/133-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 50mm diameter",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 27,
          "amount_aed": 216,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "135.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27.00",
            "TOWER 4 [R]": "54.00",
            "[S]": "TRUE",
            "[T]": "-81"
          }
        },
        {
          "id": "2 - Main/133-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 82mm diameter",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 30,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "270.00",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "90.00",
            "[S]": "TRUE",
            "[T]": "-180"
          }
        },
        {
          "id": "2 - Main/133-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 110mm diameter",
          "quantity": 10608,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 371280,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "629",
            "Tower 1 [E]": "2,360",
            "Tower 2 [F]": "2,696",
            "Tower 3 [G]": "2,525",
            "Tower 4 [H]": "2,398",
            "TOTAL QTY [I]": "10,608",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,015.00",
            "TOWER 1 [O]": "82,600.00",
            "TOWER 2 [P]": "94,360.00",
            "TOWER 3 [Q]": "88,375.00",
            "TOWER 4 [R]": "83,930.00",
            "[S]": "TRUE",
            "[T]": "1330"
          }
        },
        {
          "id": "2 - Main/133-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 160mm diameter",
          "quantity": 237,
          "unit": "Nr.",
          "rate_aed": 40,
          "amount_aed": 9480,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7485
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "206",
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "237",
            "BASEMENTS [M]": "40.00",
            "GF & PODIUM [N]": "8,240.00",
            "TOWER 1 [O]": "560.00",
            "TOWER 2 [P]": "160.00",
            "TOWER 3 [Q]": "240.00",
            "TOWER 4 [R]": "240.00",
            "[S]": "TRUE",
            "[T]": "-320"
          }
        },
        {
          "id": "2 - Main/133-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 200mm diameter",
          "quantity": 129,
          "unit": "Nr.",
          "rate_aed": 44,
          "amount_aed": 5676,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7487
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "129",
            "BASEMENTS [M]": "704.00",
            "GF & PODIUM [N]": "4,972.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 250mm diameter",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 49,
          "amount_aed": 1911,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7489
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "294.00",
            "GF & PODIUM [N]": "1,617.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 300mm diameter",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 54,
          "amount_aed": 486,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7491
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "54.00",
            "GF & PODIUM [N]": "432.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 350mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 350mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 59,
          "amount_aed": 59,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7493
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "59.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Clean out; 450mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Clean out; 450mm diameter",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 69,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7495
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "690.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Vent cowl; 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Vent cowl; 110mm diameter",
          "quantity": 27,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "500.00",
            "TOWER 2 [P]": "800.00",
            "TOWER 3 [Q]": "700.00",
            "TOWER 4 [R]": "700.00",
            "[S]": "TRUE",
            "[T]": "200"
          }
        },
        {
          "id": "2 - Main/133-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pipe accessories; complete including all fixings, supports and all ancillary works as necessary"
          ],
          "own_description": "Quick coupling for portable pump",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pipe accessories; complete including all fixings, supports and all ancillary works as necessary — Quick coupling for portable pump",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7499
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/133-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Dry floor drain; including 150 x 150mm floor grating (as per specification), PVC floor trap, perforated floor trap, rubber seal anti-microbial polymer compound, angle support, fixings; complete"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Dry floor drain; including 150 x 150mm floor grating (as per specification), PVC floor trap, perforated floor trap, rubber seal anti-microbial polymer compound, angle support, fixings; complete — 82mm diameter",
          "quantity": 408,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 40800,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "96",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "102",
            "TOTAL QTY [I]": "408",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "9,400.00",
            "TOWER 2 [P]": "9,600.00",
            "TOWER 3 [Q]": "10,400.00",
            "TOWER 4 [R]": "10,200.00",
            "[S]": "TRUE",
            "[T]": "800"
          }
        },
        {
          "id": "2 - Main/133-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Floor drain; including floor grating (measured elsewhere), PVC floor trap, perforated floor trap, angle support, fixings; complete"
          ],
          "own_description": "82mm diameter outlet",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Floor drain; including floor grating (measured elsewhere), PVC floor trap, perforated floor trap, angle support, fixings; complete — 82mm diameter outlet",
          "quantity": 7162,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 716200,
          "amount_state": "number",
          "printed_page": "2/Q/13",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "502",
            "Tower 1 [E]": "1,614",
            "Tower 2 [F]": "1,663",
            "Tower 3 [G]": "1,765",
            "Tower 4 [H]": "1,618",
            "TOTAL QTY [I]": "7,162",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,200.00",
            "TOWER 1 [O]": "161,400.00",
            "TOWER 2 [P]": "166,300.00",
            "TOWER 3 [Q]": "176,500.00",
            "TOWER 4 [R]": "161,800.00",
            "[S]": "TRUE",
            "[T]": "400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/134",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 43470,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/134-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Floor drain; including 150 x 150mm floor grating (as per specification), PVC floor trap, perforated floor trap, angle support, fixings; complete"
          ],
          "own_description": "82mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Floor drain; including 150 x 150mm floor grating (as per specification), PVC floor trap, perforated floor trap, angle support, fixings; complete — 82mm diameter",
          "quantity": 43,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 4300,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Valve chamber; including ductile iron heavy duty manhole cover and frame, non-return valve, isolation valve, provision for mobile pumps, fixings; complete"
          ],
          "own_description": "Valve chamber; size 450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Valve chamber; including ductile iron heavy duty manhole cover and frame, non-return valve, isolation valve, provision for mobile pumps, fixings; complete — Valve chamber; size 450 x 450mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 9100,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7535
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "9,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Valve chamber; including ductile iron heavy duty manhole cover and frame, non-return valve, isolation valve, provision for mobile pumps, fixings; complete"
          ],
          "own_description": "Valve chamber; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Valve chamber; including ductile iron heavy duty manhole cover and frame, non-return valve, isolation valve, provision for mobile pumps, fixings; complete — Valve chamber; size 600 x 600mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1300,
          "amount_aed": 6500,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7537
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "6,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Heavy duty floor clean out; including 300 x 300mm HDCI cover and frame, access cap, fixings; complete"
          ],
          "own_description": "Floor clean out (FCO); 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Heavy duty floor clean out; including 300 x 300mm HDCI cover and frame, access cap, fixings; complete — Floor clean out (FCO); 110mm diameter",
          "quantity": 27,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 945,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7541
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "945.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Heavy duty floor clean out; including 300 x 300mm HDCI cover and frame, access cap, fixings; complete"
          ],
          "own_description": "Floor clean out (FCO); 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Heavy duty floor clean out; including 300 x 300mm HDCI cover and frame, access cap, fixings; complete — Floor clean out (FCO); 150mm diameter",
          "quantity": 73,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 11680,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7543
          },
          "extra_columns": {
            "Basement [C]": "73",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "11,680.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete"
          ],
          "own_description": "Floor clean out (FCO); 110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete — Floor clean out (FCO); 110mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 35,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7547
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "35.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete"
          ],
          "own_description": "Floor clean out (FCO); 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Floor clean out; including stainless steel sealed cover, rodding eye, fixings; complete — Floor clean out (FCO); 150mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 160,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary"
          ],
          "own_description": "Dry gully trap; size 300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary — Dry gully trap; size 300 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2250,
          "amount_aed": 2250,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7553
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,250.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary"
          ],
          "own_description": "Dry gully trap; size 450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary — Dry gully trap; size 450 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/134-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary"
          ],
          "own_description": "Dry gully trap; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Dry gully trap; including 300 x 300mm recessed type cover and frame, pipe inlets/outlets, civil works, 160mm diameter gully trap, and all ancillary works as necessary — Dry gully trap; size 600 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4500,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/14",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/135",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 45500,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/135-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary"
          ],
          "own_description": "Gully trap; size 450 x 450mm, 1600mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary — Gully trap; size 450 x 450mm, 1600mm depth",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7582
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "12,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary"
          ],
          "own_description": "Gully trap; size 450 x 450mm, 1800mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary — Gully trap; size 450 x 450mm, 1800mm depth",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7584
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "4,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary"
          ],
          "own_description": "Gully trap; size 450 x 450mm, 1900mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary — Gully trap; size 450 x 450mm, 1900mm depth",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7586
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "4,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary"
          ],
          "own_description": "Gully trap; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Gully trap; including clear cast iron cover and frame, pipe inlets/outlets, civil works (measured elsewhere), hopper, p-trap, uPVC grating, and all ancillary works as necessary — Gully trap; size 600 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4500,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7588
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary"
          ],
          "own_description": "Sand trap; size 1000 x 1000mm, 1200mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary — Sand trap; size 1000 x 1000mm, 1200mm depth",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7592
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary"
          ],
          "own_description": "Sand trap; size 1000 x 1000mm, 1800mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary — Sand trap; size 1000 x 1000mm, 1800mm depth",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7594
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary"
          ],
          "own_description": "Sand trap; size 1000 x 1000mm, 1870mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary — Sand trap; size 1000 x 1000mm, 1870mm depth",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7596
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary"
          ],
          "own_description": "Sand trap; size 1000 x 1000mm, 2100mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary — Sand trap; size 1000 x 1000mm, 2100mm depth",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7598
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary"
          ],
          "own_description": "Sand trap; size 1000 x 1000mm, 2200mm depth",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Sand trap; including 600 x 600mm M.D. manhole cover and frame, pipe inlets/outlets, uPVC access bend, 10mm holes perforated basket, block work, civil works (measured elsewhere) and all ancillary works as necessary — Sand trap; size 1000 x 1000mm, 2200mm depth",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7600
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/135-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary"
          ],
          "own_description": "PBMH; size 600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary — PBMH; size 600 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/Q/15",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7604
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "10,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/136",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 144000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/136-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary"
          ],
          "own_description": "PBMH; size 800 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary — PBMH; size 800 x 800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7629
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary"
          ],
          "own_description": "PBMH; size 1000 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Pressure breaking manhole; including 600 x 600mm double seal C.I. cover and frame, pressure inlet pipe, outlet pipe, vent pipe, concrete baffle, civil works and all ancillary works as necessary — PBMH; size 1000 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7631
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "15,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sump pump"
          ],
          "own_description": "T1-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 23m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sump pump — T1-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 23m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7637
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sump pump"
          ],
          "own_description": "T2-B2-SP-01; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 20m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sump pump — T2-B2-SP-01; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 20m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7639
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sump pump"
          ],
          "own_description": "T2-B2-SP-02; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 30m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sump pump — T2-B2-SP-02; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 30m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7641
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sump pump"
          ],
          "own_description": "T3-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 35m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sump pump — T3-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 35m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7643
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sump pump"
          ],
          "own_description": "T4-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 35m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sump pump — T4-B2-SP; 1 duty + 1 assist with flow rate of 2.5L/s and pump head of 35m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7645
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Lift sump pump"
          ],
          "own_description": "T1-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 25m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Lift sump pump — T1-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 25m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7649
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Lift sump pump"
          ],
          "own_description": "T2-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 25m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Lift sump pump — T2-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 25m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7651
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Lift sump pump"
          ],
          "own_description": "T3-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 35m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Lift sump pump — T3-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 35m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7653
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/136-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Lift sump pump"
          ],
          "own_description": "T4-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 35m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Lift sump pump — T4-B2-LSP; 1 duty with flow rate of 1.0L/s and pump head of 35m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/16",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7655
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/137",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 26000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/137-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sewage lifting dry pump"
          ],
          "own_description": "T2-B2-SLP; 2 duty + 2 assist with flow rate of 5.0L/s and pump head of 30m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sewage lifting dry pump — T2-B2-SLP; 2 duty + 2 assist with flow rate of 5.0L/s and pump head of 30m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/17",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7676
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/137-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary",
            "Sewage lifting dry pump"
          ],
          "own_description": "T4-B2-SLP; 1 duty + 1 assist with flow rate of 4L/s and pump head of 35m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — DRAINAGE INSTALLATION — Equipment; including float switches, alarms, guide rails, control panel, wirings, electrical power connections, supports, fixings, accessories and all ancillary works as necessary — Sewage lifting dry pump — T4-B2-SLP; 1 duty + 1 assist with flow rate of 4L/s and pump head of 35m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13000,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/Q/17",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7678
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "13,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/138",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 10734885,
      "section_notes": [
        "Note: Refer to the following:",
        "1. Water supply floor plan (Basement to Podium) Drawing Nr.ZD-3250587-CKR-DWG-PDM-PLD-6000 to 6996",
        "2. Water supply floor plan (Tower 1) Drawing Nr. ZD-3250587-CKR-DWG-TW1-PLD-6040 to 6510",
        "3. Water supply floor plan (Tower 2) Drawing Nr. ZD-3250587-CKR-DWG-TW2-PLD-6040 to 6590",
        "4. Water supply floor plan (Tower 3) Drawing Nr. ZD-3250587-CKR-DWG-TW3-PLD-6040 to 6550",
        "5. Water supply floor plan (Tower 4) Drawing Nr. ZD-3250587-CKR-DWG-TW4-PLD-6040 to 6550",
        "6. Water supply schematics Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD-6601",
        "7. Water supply standard details and notes Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD-6501 to 6503",
        "8. MEP Specification Document Nr. ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/138-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "15mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 15mm diameter",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 30,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/138-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 20mm diameter",
          "quantity": 46273,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 3239110,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7783
          },
          "extra_columns": {
            "Basement [C]": "1,262",
            "GF & Podium [D]": "3,443",
            "Tower 1 [E]": "10,027",
            "Tower 2 [F]": "10,160",
            "Tower 3 [G]": "11,288",
            "Tower 4 [H]": "10,093",
            "TOTAL QTY [I]": "46,273",
            "BASEMENTS [M]": "88,340.00",
            "GF & PODIUM [N]": "241,010.00",
            "TOWER 1 [O]": "701,890.00",
            "TOWER 2 [P]": "711,200.00",
            "TOWER 3 [Q]": "790,160.00",
            "TOWER 4 [R]": "706,510.00",
            "[S]": "TRUE",
            "[T]": "4620"
          }
        },
        {
          "id": "2 - Main/138-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 25mm diameter",
          "quantity": 13620,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1089600,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7785
          },
          "extra_columns": {
            "Basement [C]": "80",
            "GF & Podium [D]": "1,869",
            "Tower 1 [E]": "5,021",
            "Tower 2 [F]": "2,157",
            "Tower 3 [G]": "2,337",
            "Tower 4 [H]": "2,156",
            "TOTAL QTY [I]": "13,620",
            "BASEMENTS [M]": "6,400.00",
            "GF & PODIUM [N]": "149,520.00",
            "TOWER 1 [O]": "401,680.00",
            "TOWER 2 [P]": "172,560.00",
            "TOWER 3 [Q]": "186,960.00",
            "TOWER 4 [R]": "172,480.00",
            "[S]": "TRUE",
            "[T]": "-229200"
          }
        },
        {
          "id": "2 - Main/138-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 32mm diameter",
          "quantity": 38373,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 3453570,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "831",
            "Tower 1 [E]": "7,392",
            "Tower 2 [F]": "9,577",
            "Tower 3 [G]": "10,839",
            "Tower 4 [H]": "9,734",
            "TOTAL QTY [I]": "38,373",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "74,790.00",
            "TOWER 1 [O]": "665,280.00",
            "TOWER 2 [P]": "861,930.00",
            "TOWER 3 [Q]": "975,510.00",
            "TOWER 4 [R]": "876,060.00",
            "[S]": "TRUE",
            "[T]": "210780"
          }
        },
        {
          "id": "2 - Main/138-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 40mm diameter",
          "quantity": 507,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 60840,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7789
          },
          "extra_columns": {
            "Basement [C]": "79",
            "GF & Podium [D]": "60",
            "Tower 1 [E]": "34",
            "Tower 2 [F]": "291",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "35",
            "TOTAL QTY [I]": "507",
            "BASEMENTS [M]": "9,480.00",
            "GF & PODIUM [N]": "7,200.00",
            "TOWER 1 [O]": "4,080.00",
            "TOWER 2 [P]": "34,920.00",
            "TOWER 3 [Q]": "960.00",
            "TOWER 4 [R]": "4,200.00",
            "[S]": "TRUE",
            "[T]": "120"
          }
        },
        {
          "id": "2 - Main/138-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 50mm diameter",
          "quantity": 462,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 69300,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7791
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "123",
            "Tower 1 [E]": "133",
            "Tower 2 [F]": "67",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "128",
            "TOTAL QTY [I]": "462",
            "BASEMENTS [M]": "1,650.00",
            "GF & PODIUM [N]": "18,450.00",
            "TOWER 1 [O]": "19,950.00",
            "TOWER 2 [P]": "10,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "19,200.00",
            "[S]": "TRUE",
            "[T]": "-750"
          }
        },
        {
          "id": "2 - Main/138-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 65mm diameter",
          "quantity": 183,
          "unit": "m",
          "rate_aed": 275,
          "amount_aed": 50325,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7793
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "166",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "183",
            "BASEMENTS [M]": "2,475.00",
            "GF & PODIUM [N]": "45,650.00",
            "TOWER 1 [O]": "825.00",
            "TOWER 2 [P]": "275.00",
            "TOWER 3 [Q]": "825.00",
            "TOWER 4 [R]": "275.00",
            "[S]": "TRUE",
            "[T]": "-550"
          }
        },
        {
          "id": "2 - Main/138-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 110mm diameter",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 430,
          "amount_aed": 16770,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "430.00",
            "TOWER 1 [O]": "11,180.00",
            "TOWER 2 [P]": "1,290.00",
            "TOWER 3 [Q]": "2,150.00",
            "TOWER 4 [R]": "1,720.00",
            "[S]": "TRUE",
            "[T]": "-9460"
          }
        },
        {
          "id": "2 - Main/138-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Gravity cold water supply (GCWS)"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Gravity cold water supply (GCWS) — 125mm diameter",
          "quantity": 174,
          "unit": "m",
          "rate_aed": 630,
          "amount_aed": 109620,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "66",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,380.00",
            "TOWER 2 [P]": "27,720.00",
            "TOWER 3 [Q]": "41,580.00",
            "TOWER 4 [R]": "23,940.00",
            "[S]": "TRUE",
            "[T]": "7560"
          }
        },
        {
          "id": "2 - Main/138-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 20mm diameter",
          "quantity": 420,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 29400,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "149",
            "Tower 2 [F]": "77",
            "Tower 3 [G]": "47",
            "Tower 4 [H]": "147",
            "TOTAL QTY [I]": "420",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,430.00",
            "TOWER 2 [P]": "5,390.00",
            "TOWER 3 [Q]": "3,290.00",
            "TOWER 4 [R]": "10,290.00",
            "[S]": "TRUE",
            "[T]": "-140"
          }
        },
        {
          "id": "2 - Main/138-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 25mm diameter",
          "quantity": 204,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16320,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "34",
            "Tower 2 [F]": "102",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "64",
            "TOTAL QTY [I]": "204",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,720.00",
            "TOWER 2 [P]": "8,160.00",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "5,120.00",
            "[S]": "TRUE",
            "[T]": "2400"
          }
        },
        {
          "id": "2 - Main/138-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 32mm diameter",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,260.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1260"
          }
        },
        {
          "id": "2 - Main/138-N",
          "item_code": "N",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 40mm diameter",
          "quantity": 481,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 57720,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "213",
            "Tower 3 [G]": "15",
            "Tower 4 [H]": "213",
            "TOTAL QTY [I]": "481",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "25,560.00",
            "TOWER 3 [Q]": "1,800.00",
            "TOWER 4 [R]": "25,560.00",
            "[S]": "TRUE",
            "[T]": "20760"
          }
        },
        {
          "id": "2 - Main/138-P",
          "item_code": "P",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 50mm diameter",
          "quantity": 114,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "51",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "30",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "7,650.00",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "4,500.00",
            "[S]": "TRUE",
            "[T]": "2700"
          }
        },
        {
          "id": "2 - Main/138-Q",
          "item_code": "Q",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 65mm diameter",
          "quantity": 124,
          "unit": "m",
          "rate_aed": 275,
          "amount_aed": 34100,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "41",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "54",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,500.00",
            "TOWER 2 [P]": "11,275.00",
            "TOWER 3 [Q]": "2,475.00",
            "TOWER 4 [R]": "14,850.00",
            "[S]": "TRUE",
            "[T]": "9350"
          }
        },
        {
          "id": "2 - Main/138-R",
          "item_code": "R",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 75mm diameter",
          "quantity": 93,
          "unit": "m",
          "rate_aed": 340,
          "amount_aed": 31620,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "56",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,580.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "19,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12580"
          }
        },
        {
          "id": "2 - Main/138-S",
          "item_code": "S",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Boosted cold water supply (BCWS)"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Boosted cold water supply (BCWS) — 110mm diameter",
          "quantity": 4,
          "unit": "m",
          "rate_aed": 430,
          "amount_aed": 1720,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,720.00",
            "[S]": "TRUE",
            "[T]": "1720"
          }
        },
        {
          "id": "2 - Main/138-T",
          "item_code": "T",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Hot water supply (HWS)"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Hot water supply (HWS) — 20mm diameter",
          "quantity": 35056,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 2453920,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7819
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,218",
            "Tower 1 [E]": "8,041",
            "Tower 2 [F]": "8,277",
            "Tower 3 [G]": "9,214",
            "Tower 4 [H]": "8,306",
            "TOTAL QTY [I]": "35,056",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "85,260.00",
            "TOWER 1 [O]": "562,870.00",
            "TOWER 2 [P]": "579,390.00",
            "TOWER 3 [Q]": "644,980.00",
            "TOWER 4 [R]": "581,420.00",
            "[S]": "TRUE",
            "[T]": "18550"
          }
        },
        {
          "id": "2 - Main/138-U",
          "item_code": "U",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "Hot water supply (HWS)"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — Hot water supply (HWS) — 25mm diameter",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/Q/19",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7821
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/139",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2052310,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/139-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Cold water installation; including supports, hangers, markings and all ancillary works as necessary",
            "Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings",
            "TSE incoming pipe"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Cold water installation; including supports, hangers, markings and all ancillary works as necessary — Above ground cold water PPR to DIN - 8077, SDR 7.4 pipes and fittings — TSE incoming pipe — 25mm diameter",
          "quantity": 143,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 7150,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7839
          },
          "extra_columns": {
            "Basement [C]": "143",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "7,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 20mm diameter",
          "quantity": 251,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 17570,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "32",
            "Tower 2 [F]": "88",
            "Tower 3 [G]": "35",
            "Tower 4 [H]": "35",
            "TOTAL QTY [I]": "251",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,270.00",
            "TOWER 1 [O]": "2,240.00",
            "TOWER 2 [P]": "6,160.00",
            "TOWER 3 [Q]": "2,450.00",
            "TOWER 4 [R]": "2,450.00",
            "[S]": "TRUE",
            "[T]": "210"
          }
        },
        {
          "id": "2 - Main/139-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 25mm diameter",
          "quantity": 618,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 49440,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "137",
            "Tower 2 [F]": "185",
            "Tower 3 [G]": "165",
            "Tower 4 [H]": "125",
            "TOTAL QTY [I]": "618",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "480.00",
            "TOWER 1 [O]": "10,960.00",
            "TOWER 2 [P]": "14,800.00",
            "TOWER 3 [Q]": "13,200.00",
            "TOWER 4 [R]": "10,000.00",
            "[S]": "TRUE",
            "[T]": "-960"
          }
        },
        {
          "id": "2 - Main/139-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 50mm diameter",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "1,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,050.00",
            "TOWER 4 [R]": "1,050.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 65mm diameter",
          "quantity": 260,
          "unit": "m",
          "rate_aed": 275,
          "amount_aed": 71500,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "166",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "260",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "7,150.00",
            "TOWER 2 [P]": "6,875.00",
            "TOWER 3 [Q]": "45,650.00",
            "TOWER 4 [R]": "5,775.00",
            "[S]": "TRUE",
            "[T]": "-1375"
          }
        },
        {
          "id": "2 - Main/139-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 75mm diameter",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 350,
          "amount_aed": 15050,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "11",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,350.00",
            "TOWER 3 [Q]": "3,850.00",
            "TOWER 4 [R]": "3,850.00",
            "[S]": "TRUE",
            "[T]": "3850"
          }
        },
        {
          "id": "2 - Main/139-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 110mm diameter",
          "quantity": 350,
          "unit": "m",
          "rate_aed": 430,
          "amount_aed": 150500,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "88",
            "Tower 3 [G]": "74",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "350",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,720.00",
            "TOWER 1 [O]": "39,560.00",
            "TOWER 2 [P]": "37,840.00",
            "TOWER 3 [Q]": "31,820.00",
            "TOWER 4 [R]": "39,560.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Gravity cold water supply riser (GCWS)"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Gravity cold water supply riser (GCWS) — 125mm diameter",
          "quantity": 328,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 160720,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "61",
            "Tower 2 [F]": "97",
            "Tower 3 [G]": "98",
            "Tower 4 [H]": "72",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "29,890.00",
            "TOWER 2 [P]": "47,530.00",
            "TOWER 3 [Q]": "48,020.00",
            "TOWER 4 [R]": "35,280.00",
            "[S]": "TRUE",
            "[T]": "5390"
          }
        },
        {
          "id": "2 - Main/139-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Circulation pipes and fittings"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Circulation pipes and fittings — 75mm diameter",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 350,
          "amount_aed": 9100,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7861
          },
          "extra_columns": {
            "Basement [C]": "26",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "9,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Hard copper transfer pipes and fittings",
            "Cold water transfer pipe (WTP)"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Hard copper transfer pipes and fittings — Cold water transfer pipe (WTP) — 40mm diameter",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 4140,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,620.00",
            "TOWER 2 [P]": "900.00",
            "TOWER 3 [Q]": "720.00",
            "TOWER 4 [R]": "900.00",
            "[S]": "TRUE",
            "[T]": "-720"
          }
        },
        {
          "id": "2 - Main/139-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Hard copper transfer pipes and fittings",
            "Cold water transfer pipe (WTP)"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Hard copper transfer pipes and fittings — Cold water transfer pipe (WTP) — 50mm diameter",
          "quantity": 536,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 107200,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "130",
            "Tower 2 [F]": "148",
            "Tower 3 [G]": "145",
            "Tower 4 [H]": "113",
            "TOTAL QTY [I]": "536",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,000.00",
            "TOWER 2 [P]": "29,600.00",
            "TOWER 3 [Q]": "29,000.00",
            "TOWER 4 [R]": "22,600.00",
            "[S]": "TRUE",
            "[T]": "-3400"
          }
        },
        {
          "id": "2 - Main/139-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Hard copper transfer pipes and fittings",
            "Cold water transfer pipe (WTP)"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Hard copper transfer pipes and fittings — Cold water transfer pipe (WTP) — 65mm diameter",
          "quantity": 1092,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 240240,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7871
          },
          "extra_columns": {
            "Basement [C]": "558",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "109",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "131",
            "Tower 4 [H]": "110",
            "TOTAL QTY [I]": "1,092",
            "BASEMENTS [M]": "122,760.00",
            "GF & PODIUM [N]": "16,280.00",
            "TOWER 1 [O]": "23,980.00",
            "TOWER 2 [P]": "24,200.00",
            "TOWER 3 [Q]": "28,820.00",
            "TOWER 4 [R]": "24,200.00",
            "[S]": "TRUE",
            "[T]": "220"
          }
        },
        {
          "id": "2 - Main/139-N",
          "item_code": "N",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Hard copper transfer pipes and fittings",
            "Cold water transfer pipe (WTP)"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Hard copper transfer pipes and fittings — Cold water transfer pipe (WTP) — 110mm diameter",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 370,
          "amount_aed": 4070,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7873
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "4,070.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-P",
          "item_code": "P",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings",
            "Hard copper transfer pipes and fittings",
            "Cold water transfer pipe (WTP)"
          ],
          "own_description": "160mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Above ground cold water PPR to DIN - 8077, SDR 6.0 pipes and fittings — Hard copper transfer pipes and fittings — Cold water transfer pipe (WTP) — 160mm diameter",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 540,
          "amount_aed": 5400,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7875
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "5,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/139-Q",
          "item_code": "Q",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "PEX pipes and fittings within wall embedded with conduits"
          ],
          "own_description": "16mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — PEX pipes and fittings within wall embedded with conduits — 16mm diameter",
          "quantity": 34398,
          "unit": "m",
          "rate_aed": 35,
          "amount_aed": 1203930,
          "amount_state": "number",
          "printed_page": "2/Q/20",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,158",
            "Tower 1 [E]": "8,420",
            "Tower 2 [F]": "8,020",
            "Tower 3 [G]": "8,832",
            "Tower 4 [H]": "7,968",
            "TOTAL QTY [I]": "34,398",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,530.00",
            "TOWER 1 [O]": "294,700.00",
            "TOWER 2 [P]": "280,700.00",
            "TOWER 3 [Q]": "309,120.00",
            "TOWER 4 [R]": "278,880.00",
            "[S]": "TRUE",
            "[T]": "-15820"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/140",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2298635,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/140-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "uPVC class E pipes and fittings"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — uPVC class E pipes and fittings — 25mm diameter",
          "quantity": 143,
          "unit": "m",
          "rate_aed": 30,
          "amount_aed": 4290,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7898
          },
          "extra_columns": {
            "Basement [C]": "143",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "4,290.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/140-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "uPVC class E pipes and fittings"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — uPVC class E pipes and fittings — 50mm diameter",
          "quantity": 168,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 16800,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7900
          },
          "extra_columns": {
            "Basement [C]": "168",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "168",
            "BASEMENTS [M]": "16,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/140-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "uPVC class E pipes and fittings"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — uPVC class E pipes and fittings — 150mm diameter",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 5625,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7902
          },
          "extra_columns": {
            "Basement [C]": "45",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "5,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/140-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pipe insulation; including supports, fixings, markings and all ancillary works as necessary",
            "19mm thick closed cell elastomeric foam insulation to PPR hot water pipe"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pipe insulation; including supports, fixings, markings and all ancillary works as necessary — 19mm thick closed cell elastomeric foam insulation to PPR hot water pipe — 20mm diameter",
          "quantity": 35056,
          "unit": "m",
          "rate_aed": 25,
          "amount_aed": 876400,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,218",
            "Tower 1 [E]": "8,041",
            "Tower 2 [F]": "8,277",
            "Tower 3 [G]": "9,214",
            "Tower 4 [H]": "8,306",
            "TOTAL QTY [I]": "35,056",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,450.00",
            "TOWER 1 [O]": "201,025.00",
            "TOWER 2 [P]": "206,925.00",
            "TOWER 3 [Q]": "230,350.00",
            "TOWER 4 [R]": "207,650.00",
            "[S]": "TRUE",
            "[T]": "6625"
          }
        },
        {
          "id": "2 - Main/140-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 20mm diameter",
          "quantity": 341,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 17050,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "67",
            "Tower 2 [F]": "72",
            "Tower 3 [G]": "107",
            "Tower 4 [H]": "95",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,350.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "5,350.00",
            "TOWER 4 [R]": "4,750.00",
            "[S]": "TRUE",
            "[T]": "1400"
          }
        },
        {
          "id": "2 - Main/140-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 25mm diameter",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7914
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "36",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,220.00",
            "[S]": "TRUE",
            "[T]": "2220"
          }
        },
        {
          "id": "2 - Main/140-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 32mm diameter",
          "quantity": 152,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12160,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7916
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "26",
            "Tower 4 [H]": "50",
            "TOTAL QTY [I]": "152",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,640.00",
            "TOWER 2 [P]": "1,440.00",
            "TOWER 3 [Q]": "2,080.00",
            "TOWER 4 [R]": "4,000.00",
            "[S]": "TRUE",
            "[T]": "-640"
          }
        },
        {
          "id": "2 - Main/140-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 65mm diameter",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 8030,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7918
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "28",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,080.00",
            "TOWER 3 [Q]": "110.00",
            "TOWER 4 [R]": "4,840.00",
            "[S]": "TRUE",
            "[T]": "4840"
          }
        },
        {
          "id": "2 - Main/140-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 75mm diameter",
          "quantity": 93,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 11160,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7920
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "56",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,440.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4440"
          }
        },
        {
          "id": "2 - Main/140-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 110mm diameter",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7922
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "625.00",
            "TOWER 2 [P]": "375.00",
            "TOWER 3 [Q]": "625.00",
            "TOWER 4 [R]": "875.00",
            "[S]": "TRUE",
            "[T]": "250"
          }
        },
        {
          "id": "2 - Main/140-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Aluminum cladding to all exposed pipes and fittings; including RC/solid block support with plaster and epoxy, rubber pad, pipe insulations, fixing clamps, accessories and all ancillary works necessary — 125mm diameter",
          "quantity": 96,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7924
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,900.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "3,300.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE",
            "[T]": "-300"
          }
        },
        {
          "id": "2 - Main/140-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 20mm diameter",
          "quantity": 16573,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 1325840,
          "amount_state": "number",
          "printed_page": "2/Q/21",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7930
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "687",
            "Tower 1 [E]": "3,821",
            "Tower 2 [F]": "3,870",
            "Tower 3 [G]": "4,261",
            "Tower 4 [H]": "3,857",
            "TOTAL QTY [I]": "16,573",
            "BASEMENTS [M]": "6,160.00",
            "GF & PODIUM [N]": "54,960.00",
            "TOWER 1 [O]": "305,680.00",
            "TOWER 2 [P]": "309,600.00",
            "TOWER 3 [Q]": "340,880.00",
            "TOWER 4 [R]": "308,560.00",
            "[S]": "TRUE",
            "[T]": "2880"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/141",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 641325,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/141-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 25mm diameter",
          "quantity": 364,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 36400,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7949
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "79",
            "Tower 1 [E]": "156",
            "Tower 2 [F]": "66",
            "Tower 3 [G]": "43",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "400.00",
            "GF & PODIUM [N]": "7,900.00",
            "TOWER 1 [O]": "15,600.00",
            "TOWER 2 [P]": "6,600.00",
            "TOWER 3 [Q]": "4,300.00",
            "TOWER 4 [R]": "1,600.00",
            "[S]": "TRUE",
            "[T]": "-14000"
          }
        },
        {
          "id": "2 - Main/141-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 32mm diameter",
          "quantity": 1511,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 226650,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "261",
            "Tower 2 [F]": "381",
            "Tower 3 [G]": "428",
            "Tower 4 [H]": "404",
            "TOTAL QTY [I]": "1,511",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,550.00",
            "TOWER 1 [O]": "39,150.00",
            "TOWER 2 [P]": "57,150.00",
            "TOWER 3 [Q]": "64,200.00",
            "TOWER 4 [R]": "60,600.00",
            "[S]": "TRUE",
            "[T]": "21450"
          }
        },
        {
          "id": "2 - Main/141-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 40mm diameter",
          "quantity": 68,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 12240,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7953
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "23",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "26",
            "TOTAL QTY [I]": "68",
            "BASEMENTS [M]": "540.00",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "720.00",
            "TOWER 2 [P]": "4,140.00",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "4,680.00",
            "[S]": "TRUE",
            "[T]": "3960"
          }
        },
        {
          "id": "2 - Main/141-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 50mm diameter",
          "quantity": 1009,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 272430,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7955
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "228",
            "Tower 2 [F]": "252",
            "Tower 3 [G]": "254",
            "Tower 4 [H]": "234",
            "TOTAL QTY [I]": "1,009",
            "BASEMENTS [M]": "1,620.00",
            "GF & PODIUM [N]": "9,450.00",
            "TOWER 1 [O]": "61,560.00",
            "TOWER 2 [P]": "68,040.00",
            "TOWER 3 [Q]": "68,580.00",
            "TOWER 4 [R]": "63,180.00",
            "[S]": "TRUE",
            "[T]": "1620"
          }
        },
        {
          "id": "2 - Main/141-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 65mm diameter",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 18200,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7957
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "4,900.00",
            "GF & PODIUM [N]": "3,500.00",
            "TOWER 1 [O]": "1,400.00",
            "TOWER 2 [P]": "2,800.00",
            "TOWER 3 [Q]": "5,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1400"
          }
        },
        {
          "id": "2 - Main/141-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 75mm diameter",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 9600,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7959
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "1,600.00",
            "TOWER 3 [Q]": "2,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2400"
          }
        },
        {
          "id": "2 - Main/141-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "110mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 110mm diameter",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 19800,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7961
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "1,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,400.00",
            "TOWER 2 [P]": "3,300.00",
            "TOWER 3 [Q]": "2,200.00",
            "TOWER 4 [R]": "8,800.00",
            "[S]": "TRUE",
            "[T]": "4400"
          }
        },
        {
          "id": "2 - Main/141-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 125mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE",
            "[T]": "1500"
          }
        },
        {
          "id": "2 - Main/141-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Isolation valve — 150mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1800,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7965
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "7,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 25mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7969
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "200.00",
            "[S]": "TRUE",
            "[T]": "200"
          }
        },
        {
          "id": "2 - Main/141-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 32mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "180.00",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "180.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 40mm diameter",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 5500,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7973
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "500.00",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "2,000.00",
            "TOWER 2 [P]": "1,000.00",
            "TOWER 3 [Q]": "1,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2000"
          }
        },
        {
          "id": "2 - Main/141-N",
          "item_code": "N",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 50mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7975
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-P",
          "item_code": "P",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 65mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7977
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "1,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-Q",
          "item_code": "Q",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Motorized valve"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Motorized valve — 75mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1900,
          "amount_aed": 7600,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7979
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "7,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-R",
          "item_code": "R",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Solenoid valve — 40mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 575,
          "amount_aed": 575,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7983
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "575.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-S",
          "item_code": "S",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Non-return valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Non-return valve — 40mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 850,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7987
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "850.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/141-T",
          "item_code": "T",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Air vent"
          ],
          "own_description": "AV; to 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Air vent — AV; to 65mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "2/Q/22",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 7991
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "50.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "50.00",
            "[S]": "TRUE",
            "[T]": "50"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/142",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 172985,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/142-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Air vent"
          ],
          "own_description": "AV; to 75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Air vent — AV; to 75mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 55,
          "amount_aed": 110,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "55.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "55.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-55"
          }
        },
        {
          "id": "2 - Main/142-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Air vent"
          ],
          "own_description": "AV; to 125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Air vent — AV; to 125mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 70,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "70.00",
            "TOWER 2 [P]": "70.00",
            "TOWER 3 [Q]": "140.00",
            "TOWER 4 [R]": "70.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 25mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 275,
          "amount_aed": 275,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8013
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "275.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 32mm diameter",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "700.00",
            "TOWER 2 [P]": "1,400.00",
            "TOWER 3 [Q]": "700.00",
            "TOWER 4 [R]": "350.00",
            "[S]": "TRUE",
            "[T]": "-350"
          }
        },
        {
          "id": "2 - Main/142-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 40mm diameter",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 5850,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8017
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "450.00",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "900.00",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "900.00",
            "[S]": "TRUE",
            "[T]": "-900"
          }
        },
        {
          "id": "2 - Main/142-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 50mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8019
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "4,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 65mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 12500,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "2,500.00",
            "[S]": "TRUE",
            "[T]": "2500"
          }
        },
        {
          "id": "2 - Main/142-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Float valve"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Float valve — 75mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8023
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Foot valve"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Foot valve — 150mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8027
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 20mm diameter",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,000.00",
            "TOWER 1 [O]": "2,000.00",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE",
            "[T]": "1000"
          }
        },
        {
          "id": "2 - Main/142-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 25mm diameter",
          "quantity": 40,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 60000,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8033
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "1,500.00",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "10,500.00",
            "TOWER 2 [P]": "15,000.00",
            "TOWER 3 [Q]": "13,500.00",
            "TOWER 4 [R]": "9,000.00",
            "[S]": "TRUE",
            "[T]": "-1500"
          }
        },
        {
          "id": "2 - Main/142-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 32mm diameter",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 17000,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8035
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,600.00",
            "TOWER 1 [O]": "1,700.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,700.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-N",
          "item_code": "N",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 40mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2200,
          "amount_aed": 8800,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8037
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,800.00",
            "[S]": "TRUE",
            "[T]": "8800"
          }
        },
        {
          "id": "2 - Main/142-P",
          "item_code": "P",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 50mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2900,
          "amount_aed": 11600,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8039
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-Q",
          "item_code": "Q",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Accessories; including hangers, supports and all ancillary work as necessary",
            "Pressure reducing valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Accessories; including hangers, supports and all ancillary work as necessary — Pressure reducing valve — 65mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3770,
          "amount_aed": 7540,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8041
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "3,770.00",
            "GF & PODIUM [N]": "3,770.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/142-R",
          "item_code": "R",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves — 65mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 3770,
          "amount_aed": 11310,
          "amount_state": "number",
          "printed_page": "2/Q/23",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8045
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,310.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/143",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2870070,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/143-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves"
          ],
          "own_description": "75mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves — 75mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,000.00",
            "TOWER 2 [P]": "4,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4000"
          }
        },
        {
          "id": "2 - Main/143-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves — 100mm diameter",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 68000,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "8,500.00",
            "TOWER 2 [P]": "8,500.00",
            "TOWER 3 [Q]": "25,500.00",
            "TOWER 4 [R]": "17,000.00",
            "[S]": "TRUE",
            "[T]": "8500"
          }
        },
        {
          "id": "2 - Main/143-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves"
          ],
          "own_description": "125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at vertical riser; including 4nr. isolation valves, 2nr. of pressure gauge and 2nr. pressure reducing valves — 125mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 52500,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,500.00",
            "TOWER 2 [P]": "10,500.00",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "10,500.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge — 25mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge — 32mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 3400,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge — 40mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2200,
          "amount_aed": 11000,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,200.00",
            "TOWER 3 [Q]": "2,200.00",
            "TOWER 4 [R]": "2,200.00",
            "[S]": "TRUE",
            "[T]": "2200"
          }
        },
        {
          "id": "2 - Main/143-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pressure reducing valve (PRV) station at floor branch; including 2nr. of pressure gauge — 50mm diameter",
          "quantity": 399,
          "unit": "Nr.",
          "rate_aed": 2900,
          "amount_aed": 1157100,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "97",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "95",
            "TOTAL QTY [I]": "399",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,600.00",
            "TOWER 1 [O]": "263,900.00",
            "TOWER 2 [P]": "281,300.00",
            "TOWER 3 [Q]": "295,800.00",
            "TOWER 4 [R]": "275,500.00",
            "[S]": "TRUE",
            "[T]": "11600"
          }
        },
        {
          "id": "2 - Main/143-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Bib tap with lockable type quick coupling"
          ],
          "own_description": "15mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Bib tap with lockable type quick coupling — 15mm diameter",
          "quantity": 447,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 35760,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8081
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "60",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "68",
            "Tower 4 [H]": "69",
            "TOTAL QTY [I]": "447",
            "BASEMENTS [M]": "6,160.00",
            "GF & PODIUM [N]": "8,000.00",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "5,840.00",
            "TOWER 3 [Q]": "5,440.00",
            "TOWER 4 [R]": "5,520.00",
            "[S]": "TRUE",
            "[T]": "720"
          }
        },
        {
          "id": "2 - Main/143-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Drain valve"
          ],
          "own_description": "To 20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Drain valve — To 20mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 80,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-K",
          "item_code": "K",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Drain valve"
          ],
          "own_description": "To 40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Drain valve — To 40mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 180,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-L",
          "item_code": "L",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Drain valve"
          ],
          "own_description": "To 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Drain valve — To 50mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 810,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "270.00",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-M",
          "item_code": "M",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Drain valve"
          ],
          "own_description": "To 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Drain valve — To 65mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8091
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "700.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/143-N",
          "item_code": "N",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Gate valve"
          ],
          "own_description": "1/2\" diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Gate valve — 1/2\" diameter",
          "quantity": 3466,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 277280,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "134",
            "Tower 1 [E]": "812",
            "Tower 2 [F]": "828",
            "Tower 3 [G]": "908",
            "Tower 4 [H]": "784",
            "TOTAL QTY [I]": "3,466",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,720.00",
            "TOWER 1 [O]": "64,960.00",
            "TOWER 2 [P]": "66,240.00",
            "TOWER 3 [Q]": "72,640.00",
            "TOWER 4 [R]": "62,720.00",
            "[S]": "TRUE",
            "[T]": "-2240"
          }
        },
        {
          "id": "2 - Main/143-P",
          "item_code": "P",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Water meter; including stop cock, outlet and inlet nozzles (by DEWA)"
          ],
          "own_description": "1/2\" diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Water meter; including stop cock, outlet and inlet nozzles (by DEWA) — 1/2\" diameter",
          "quantity": 1733,
          "unit": "Nr.",
          "rate_aed": 720,
          "amount_aed": 1247760,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "67",
            "Tower 1 [E]": "406",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "392",
            "TOTAL QTY [I]": "1,733",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,240.00",
            "TOWER 1 [O]": "292,320.00",
            "TOWER 2 [P]": "298,080.00",
            "TOWER 3 [Q]": "326,880.00",
            "TOWER 4 [R]": "282,240.00",
            "[S]": "TRUE",
            "[T]": "-10080"
          }
        },
        {
          "id": "2 - Main/143-Q",
          "item_code": "Q",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Water meters"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Water meters — 25mm diameter",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/Q/24",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8103
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "600.00",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "2,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "600.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/144",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2673050,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/144-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Water meters"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Water meters — 32mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8120
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-800"
          }
        },
        {
          "id": "2 - Main/144-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Water meters"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Water meters — 40mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8122
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "900.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/144-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Water meters"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Water meters — 65mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 4200,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8124
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "2,100.00",
            "GF & PODIUM [N]": "2,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/144-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary",
            "Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete"
          ],
          "own_description": "WH-02; 50L capacity",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary — Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete — WH-02; 50L capacity",
          "quantity": 2510,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 2008000,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "85",
            "Tower 1 [E]": "585",
            "Tower 2 [F]": "589",
            "Tower 3 [G]": "661",
            "Tower 4 [H]": "590",
            "TOTAL QTY [I]": "2,510",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "68,000.00",
            "TOWER 1 [O]": "468,000.00",
            "TOWER 2 [P]": "471,200.00",
            "TOWER 3 [Q]": "528,800.00",
            "TOWER 4 [R]": "472,000.00",
            "[S]": "TRUE",
            "[T]": "4000"
          }
        },
        {
          "id": "2 - Main/144-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary",
            "Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete"
          ],
          "own_description": "WH-03; 80L capacity",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary — Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete — WH-03; 80L capacity",
          "quantity": 337,
          "unit": "Nr.",
          "rate_aed": 1250,
          "amount_aed": 421250,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "50",
            "Tower 2 [F]": "137",
            "Tower 3 [G]": "58",
            "Tower 4 [H]": "87",
            "TOTAL QTY [I]": "337",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,250.00",
            "TOWER 1 [O]": "62,500.00",
            "TOWER 2 [P]": "171,250.00",
            "TOWER 3 [Q]": "72,500.00",
            "TOWER 4 [R]": "108,750.00",
            "[S]": "TRUE",
            "[T]": "46250"
          }
        },
        {
          "id": "2 - Main/144-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary",
            "Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete"
          ],
          "own_description": "WH-04; 120L capacity",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Equipment; including supports, thermostat, valves, gauges, controls, wiring, electrical power connections, accessories and all ancillary works as necessary — Electric water heater; including safety valve, pressure release valve, drain pipe connected to nearest waste pipe, flexible connections, piping connections, L-clamp; complete — WH-04; 120L capacity",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 13500,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8134
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/144-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 42m³ capacity (21m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 42m³ capacity (21m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8138
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "74,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-74800"
          }
        },
        {
          "id": "2 - Main/144-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 49m³ capacity (24.5m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 49m³ capacity (24.5m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8140
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "74,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/144-J",
          "item_code": "J",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 47m³ capacity (23.5m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 47m³ capacity (23.5m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/25",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8142
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "74,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/145",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 579000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/145-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 44m³ capacity (22m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Insulated GRP domestic water tank; including 40mm thick rigid PUF insulation, inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 44m³ capacity (22m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8168
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "74,800.00",
            "[S]": "TRUE",
            "[T]": "74800"
          }
        },
        {
          "id": "2 - Main/145-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 42m³ capacity (21m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 42m³ capacity (21m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8172
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "74,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-74800"
          }
        },
        {
          "id": "2 - Main/145-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 39m³ capacity (19.5m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 39m³ capacity (19.5m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8174
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "74,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/145-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 47m³ capacity (23.5m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 47m³ capacity (23.5m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8176
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "74,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/145-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "GRP water tank with 2 compartment; 45m³ capacity (22.5m³ each), size 3000 x 6000 x 3000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Non-insulated GRP domestic water tank; including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — GRP water tank with 2 compartment; 45m³ capacity (22.5m³ each), size 3000 x 6000 x 3000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 74800,
          "amount_aed": 74800,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8178
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "74,800.00",
            "[S]": "TRUE",
            "[T]": "74800"
          }
        },
        {
          "id": "2 - Main/145-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Domestic water tank (RCC-WATER TANK-01 & 02); including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Allowance for MEP works for Domestic water tank (RCC-WATER TANK-01 & 02); RCC tank capacity: 522m3 each; total capacity: 1044 m3",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Domestic water tank (RCC-WATER TANK-01 & 02); including inspection manhole with cover, access ladders, air vent, drain pipes, drain valves, H/L & L/L switches, level indicators, overflow pipe, flexible connections, supports, fixings, accessories and all ancillary works as necessary — Allowance for MEP works for Domestic water tank (RCC-WATER TANK-01 & 02); RCC tank capacity: 522m3 each; total capacity: 1044 m3",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 40000,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8182
          },
          "extra_columns": {
            "Basement [C]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "40,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/145-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage transfer pump; B2-T3-CWTP, 4 duty plus 1 standby, estimated flow rate at 4.2 L/s and pump head of 146m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage transfer pump; B2-T3-CWTP, 4 duty plus 1 standby, estimated flow rate at 4.2 L/s and pump head of 146m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 147600,
          "amount_aed": 147600,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8186
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "147,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/145-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Domestic water circulation pump; B2-T3-CWCP, 3 duty plus 1 assist, estimated flow rate at 8.2 L/s at 19m head",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Domestic water circulation pump; B2-T3-CWCP, 3 duty plus 1 assist, estimated flow rate at 8.2 L/s at 19m head",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/26",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8188
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "17,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/146",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 139200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/146-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage transfer pump; 29F-T1-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.0 L/s and pump head of 97m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage transfer pump; 29F-T1-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.0 L/s and pump head of 97m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8206
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17400"
          }
        },
        {
          "id": "2 - Main/146-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage transfer pump; 29F-T2-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.0 L/s and pump head of 133m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage transfer pump; 29F-T2-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.0 L/s and pump head of 133m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8208
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/146-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage transfer pump; 29F-T3-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.5 L/s and pump head of 117m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage transfer pump; 29F-T3-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.5 L/s and pump head of 117m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8210
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/146-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage transfer pump; 29F-T4-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.1 L/s and pump head of 114m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage transfer pump; 29F-T4-CWTP, 1 duty plus 1 standby, estimated flow rate at 2.1 L/s and pump head of 114m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,400.00",
            "[S]": "TRUE",
            "[T]": "17400"
          }
        },
        {
          "id": "2 - Main/146-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage booster pump; T1-51F-BCWP, 1 duty plus 1 standby, estimated flow rate at 5.1 L/s and pump head of 27m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage booster pump; T1-51F-BCWP, 1 duty plus 1 standby, estimated flow rate at 5.1 L/s and pump head of 27m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17400"
          }
        },
        {
          "id": "2 - Main/146-F",
          "item_code": "F",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage booster pump; T2-59F-BCWP, 1 duty plus 1 standby, estimated flow rate at 3.9 L/s and pump head of 27m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage booster pump; T2-59F-BCWP, 1 duty plus 1 standby, estimated flow rate at 3.9 L/s and pump head of 27m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/146-G",
          "item_code": "G",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage booster pump; T3-57F-BCWP, 1 duty plus 1 standby, estimated flow rate at 5.1 L/s and pump head of 27m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage booster pump; T3-57F-BCWP, 1 duty plus 1 standby, estimated flow rate at 5.1 L/s and pump head of 27m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/146-H",
          "item_code": "H",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary"
          ],
          "own_description": "Vertical inline multistage booster pump; T4-55F-BCWP, 1 duty plus 1 standby, estimated flow rate at 3.9 L/s and pump head of 27m",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Pumpset; including control panels, VFD, pressure vessel, pressure sensors, gauges, flexible connectors, header lines, wirings, electrical power connections, vibration isolator, valve package, BMS connection, accessories and all ancillary works as necessary — Vertical inline multistage booster pump; T4-55F-BCWP, 1 duty plus 1 standby, estimated flow rate at 3.9 L/s and pump head of 27m",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17400,
          "amount_aed": 17400,
          "amount_state": "number",
          "printed_page": "2/Q/27",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8220
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,400.00",
            "[S]": "TRUE",
            "[T]": "17400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/147",
      "section": "WATER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 25000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/147-A",
          "item_code": "A",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ground and podium",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary — To ground and podium",
          "quantity": 1,
          "unit": "item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/28",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8252
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/147-B",
          "item_code": "B",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 1",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary — To tower 1",
          "quantity": 1,
          "unit": "item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/28",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8254
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/147-C",
          "item_code": "C",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 2",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary — To tower 2",
          "quantity": 1,
          "unit": "item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/28",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8256
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/147-D",
          "item_code": "D",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 3",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary — To tower 3",
          "quantity": 1,
          "unit": "item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/28",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8258
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/147-E",
          "item_code": "E",
          "section": "WATER INSTALLATION",
          "heading_path": [
            "Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 4",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WATER INSTALLATION — Allow to advance metering infrastructure (AMI); including PVC and G.I. junction box, PVC and G.I. conduits, copper pipe connection, fixings, hangers, brackets, accessories and all ancillary works as necessary — To tower 4",
          "quantity": 1,
          "unit": "item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/28",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8260
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/148",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 9159495,
      "section_notes": [
        "Note: Refer to the following:",
        "1. Fire Fighting Standard Details Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-FPR-8502_STANDARD DETAILS AND NOTES-FIRE FIGHTING- SHEET 01 & ZD-3250587-CKR-DWG-ZZZ-FPR-8503_STANDARD DETAILS AND NOTES-FIRE FIGHTING- SHEET 01 & 02",
        "2. Fire Protection Layout Drawing ZD-3250587-CKR-DWG-ZZZ-PLD-9122 to 9344, PDM-FPR-8000 to 8996, TW1-FPR-8040  to 8520, TW2-FPR-8040 to 8600, TW3-FPR-8040 to 8560 and TW4-FPR-8040 to 8560; all inclusive",
        "3. Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-FPR-8601 to 8606; all inclusive",
        "4. Mechanical Specifications Doc. Nr. ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/148-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 25mm diameter",
          "quantity": 46146,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 4153140,
          "amount_state": "number",
          "printed_page": "2/Q/29",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8322
          },
          "extra_columns": {
            "Basement [C]": "9,663",
            "GF & Podium [D]": "8,876",
            "Tower 1 [E]": "6,781",
            "Tower 2 [F]": "7,023",
            "Tower 3 [G]": "7,033",
            "Tower 4 [H]": "6,770",
            "TOTAL QTY [I]": "46,146",
            "BASEMENTS [M]": "869,670.00",
            "GF & PODIUM [N]": "798,840.00",
            "TOWER 1 [O]": "610,290.00",
            "TOWER 2 [P]": "632,070.00",
            "TOWER 3 [Q]": "632,970.00",
            "TOWER 4 [R]": "609,300.00",
            "[S]": "TRUE",
            "[T]": "-990"
          }
        },
        {
          "id": "2 - Main/148-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 32mm diameter",
          "quantity": 6238,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 623800,
          "amount_state": "number",
          "printed_page": "2/Q/29",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8324
          },
          "extra_columns": {
            "Basement [C]": "1,970",
            "GF & Podium [D]": "1,871",
            "Tower 1 [E]": "577",
            "Tower 2 [F]": "594",
            "Tower 3 [G]": "578",
            "Tower 4 [H]": "648",
            "TOTAL QTY [I]": "6,238",
            "BASEMENTS [M]": "197,000.00",
            "GF & PODIUM [N]": "187,100.00",
            "TOWER 1 [O]": "57,700.00",
            "TOWER 2 [P]": "59,400.00",
            "TOWER 3 [Q]": "57,800.00",
            "TOWER 4 [R]": "64,800.00",
            "[S]": "TRUE",
            "[T]": "7100"
          }
        },
        {
          "id": "2 - Main/148-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 40mm diameter",
          "quantity": 7666,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 843260,
          "amount_state": "number",
          "printed_page": "2/Q/29",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8326
          },
          "extra_columns": {
            "Basement [C]": "1,396",
            "GF & Podium [D]": "1,387",
            "Tower 1 [E]": "1,039",
            "Tower 2 [F]": "1,259",
            "Tower 3 [G]": "1,332",
            "Tower 4 [H]": "1,253",
            "TOTAL QTY [I]": "7,666",
            "BASEMENTS [M]": "153,560.00",
            "GF & PODIUM [N]": "152,570.00",
            "TOWER 1 [O]": "114,290.00",
            "TOWER 2 [P]": "138,490.00",
            "TOWER 3 [Q]": "146,520.00",
            "TOWER 4 [R]": "137,830.00",
            "[S]": "TRUE",
            "[T]": "23540"
          }
        },
        {
          "id": "2 - Main/148-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 50mm diameter",
          "quantity": 12847,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 1541640,
          "amount_state": "number",
          "printed_page": "2/Q/29",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8328
          },
          "extra_columns": {
            "Basement [C]": "1,216",
            "GF & Podium [D]": "2,108",
            "Tower 1 [E]": "2,145",
            "Tower 2 [F]": "2,771",
            "Tower 3 [G]": "2,232",
            "Tower 4 [H]": "2,375",
            "TOTAL QTY [I]": "12,847",
            "BASEMENTS [M]": "145,920.00",
            "GF & PODIUM [N]": "252,960.00",
            "TOWER 1 [O]": "257,400.00",
            "TOWER 2 [P]": "332,520.00",
            "TOWER 3 [Q]": "267,840.00",
            "TOWER 4 [R]": "285,000.00",
            "[S]": "TRUE",
            "[T]": "27600"
          }
        },
        {
          "id": "2 - Main/148-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 65mm diameter",
          "quantity": 12107,
          "unit": "m",
          "rate_aed": 165,
          "amount_aed": 1997655,
          "amount_state": "number",
          "printed_page": "2/Q/29",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8330
          },
          "extra_columns": {
            "Basement [C]": "704",
            "GF & Podium [D]": "1,012",
            "Tower 1 [E]": "4,230",
            "Tower 2 [F]": "1,891",
            "Tower 3 [G]": "2,064",
            "Tower 4 [H]": "2,206",
            "TOTAL QTY [I]": "12,107",
            "BASEMENTS [M]": "116,160.00",
            "GF & PODIUM [N]": "166,980.00",
            "TOWER 1 [O]": "697,950.00",
            "TOWER 2 [P]": "312,015.00",
            "TOWER 3 [Q]": "340,560.00",
            "TOWER 4 [R]": "363,990.00",
            "[S]": "TRUE",
            "[T]": "-333960"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/149",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 14462195,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/149-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 80mm diameter",
          "quantity": 4481,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 941010,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8352
          },
          "extra_columns": {
            "Basement [C]": "629",
            "GF & Podium [D]": "704",
            "Tower 1 [E]": "785",
            "Tower 2 [F]": "765",
            "Tower 3 [G]": "611",
            "Tower 4 [H]": "987",
            "TOTAL QTY [I]": "4,481",
            "BASEMENTS [M]": "132,090.00",
            "GF & PODIUM [N]": "147,840.00",
            "TOWER 1 [O]": "164,850.00",
            "TOWER 2 [P]": "160,650.00",
            "TOWER 3 [Q]": "128,310.00",
            "TOWER 4 [R]": "207,270.00",
            "[S]": "TRUE",
            "[T]": "42420"
          }
        },
        {
          "id": "2 - Main/149-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 100mm diameter",
          "quantity": 3267,
          "unit": "m",
          "rate_aed": 270,
          "amount_aed": 882090,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8354
          },
          "extra_columns": {
            "Basement [C]": "1,081",
            "GF & Podium [D]": "796",
            "Tower 1 [E]": "512",
            "Tower 2 [F]": "342",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "431",
            "TOTAL QTY [I]": "3,267",
            "BASEMENTS [M]": "291,870.00",
            "GF & PODIUM [N]": "214,920.00",
            "TOWER 1 [O]": "138,240.00",
            "TOWER 2 [P]": "92,340.00",
            "TOWER 3 [Q]": "28,350.00",
            "TOWER 4 [R]": "116,370.00",
            "[S]": "TRUE",
            "[T]": "-21870"
          }
        },
        {
          "id": "2 - Main/149-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 150mm diameter",
          "quantity": 9179,
          "unit": "m",
          "rate_aed": 485,
          "amount_aed": 4451815,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8356
          },
          "extra_columns": {
            "Basement [C]": "4,354",
            "GF & Podium [D]": "1,603",
            "Tower 1 [E]": "483",
            "Tower 2 [F]": "1,097",
            "Tower 3 [G]": "734",
            "Tower 4 [H]": "908",
            "TOTAL QTY [I]": "9,179",
            "BASEMENTS [M]": "2,111,690.00",
            "GF & PODIUM [N]": "777,455.00",
            "TOWER 1 [O]": "234,255.00",
            "TOWER 2 [P]": "532,045.00",
            "TOWER 3 [Q]": "355,990.00",
            "TOWER 4 [R]": "440,380.00",
            "[S]": "TRUE",
            "[T]": "206125"
          }
        },
        {
          "id": "2 - Main/149-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Sprinkler pipes"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Sprinkler pipes — 200mm diameter",
          "quantity": 757,
          "unit": "m",
          "rate_aed": 680,
          "amount_aed": 514760,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8358
          },
          "extra_columns": {
            "Basement [C]": "688",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "757",
            "BASEMENTS [M]": "467,840.00",
            "GF & PODIUM [N]": "12,240.00",
            "TOWER 1 [O]": "12,240.00",
            "TOWER 2 [P]": "12,920.00",
            "TOWER 3 [Q]": "9,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12240"
          }
        },
        {
          "id": "2 - Main/149-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Wet riser pipes"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Wet riser pipes — 65mm diameter",
          "quantity": 645,
          "unit": "m",
          "rate_aed": 165,
          "amount_aed": 106425,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8362
          },
          "extra_columns": {
            "Basement [C]": "136",
            "GF & Podium [D]": "376",
            "Tower 1 [E]": "31",
            "Tower 2 [F]": "31",
            "Tower 3 [G]": "42",
            "Tower 4 [H]": "29",
            "TOTAL QTY [I]": "645",
            "BASEMENTS [M]": "22,440.00",
            "GF & PODIUM [N]": "62,040.00",
            "TOWER 1 [O]": "5,115.00",
            "TOWER 2 [P]": "5,115.00",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "4,785.00",
            "[S]": "TRUE",
            "[T]": "-330"
          }
        },
        {
          "id": "2 - Main/149-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Wet riser pipes"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Wet riser pipes — 100mm diameter",
          "quantity": 296,
          "unit": "m",
          "rate_aed": 270,
          "amount_aed": 79920,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8364
          },
          "extra_columns": {
            "Basement [C]": "173",
            "GF & Podium [D]": "58",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "296",
            "BASEMENTS [M]": "46,710.00",
            "GF & PODIUM [N]": "15,660.00",
            "TOWER 1 [O]": "2,430.00",
            "TOWER 2 [P]": "3,780.00",
            "TOWER 3 [Q]": "5,670.00",
            "TOWER 4 [R]": "5,670.00",
            "[S]": "TRUE",
            "[T]": "3240"
          }
        },
        {
          "id": "2 - Main/149-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Wet riser pipes"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Wet riser pipes — 150mm diameter",
          "quantity": 11418,
          "unit": "m",
          "rate_aed": 485,
          "amount_aed": 5537730,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8366
          },
          "extra_columns": {
            "Basement [C]": "3,822",
            "GF & Podium [D]": "4,233",
            "Tower 1 [E]": "715",
            "Tower 2 [F]": "998",
            "Tower 3 [G]": "904",
            "Tower 4 [H]": "746",
            "TOTAL QTY [I]": "11,418",
            "BASEMENTS [M]": "1,853,670.00",
            "GF & PODIUM [N]": "2,053,005.00",
            "TOWER 1 [O]": "346,775.00",
            "TOWER 2 [P]": "484,030.00",
            "TOWER 3 [Q]": "438,440.00",
            "TOWER 4 [R]": "361,810.00",
            "[S]": "TRUE",
            "[T]": "15035"
          }
        },
        {
          "id": "2 - Main/149-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Wet riser pipes"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Wet riser pipes — 200mm diameter",
          "quantity": 906,
          "unit": "m",
          "rate_aed": 680,
          "amount_aed": 616080,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "906",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "906",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "616,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/149-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Drain pipes"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Drain pipes — 80mm diameter",
          "quantity": 1735,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 364350,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8372
          },
          "extra_columns": {
            "Basement [C]": "144",
            "GF & Podium [D]": "133",
            "Tower 1 [E]": "378",
            "Tower 2 [F]": "404",
            "Tower 3 [G]": "301",
            "Tower 4 [H]": "375",
            "TOTAL QTY [I]": "1,735",
            "BASEMENTS [M]": "30,240.00",
            "GF & PODIUM [N]": "27,930.00",
            "TOWER 1 [O]": "79,380.00",
            "TOWER 2 [P]": "84,840.00",
            "TOWER 3 [Q]": "63,210.00",
            "TOWER 4 [R]": "78,750.00",
            "[S]": "TRUE",
            "[T]": "-630"
          }
        },
        {
          "id": "2 - Main/149-K",
          "item_code": "K",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire Protection System",
            "Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary",
            "Exhaust pipes"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire Protection System — Galvanized steel to ASTM A 53, schedule 40, welded steel pipes (EWR) and fittings screwed and socketed, hangers, supports, fixings, couplers and all ancillary works as necessary — Exhaust pipes — 150mm diameter",
          "quantity": 322,
          "unit": "m",
          "rate_aed": 485,
          "amount_aed": 156170,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8376
          },
          "extra_columns": {
            "Basement [C]": "31",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "106",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "95",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "322",
            "BASEMENTS [M]": "15,035.00",
            "GF & PODIUM [N]": "2,910.00",
            "TOWER 1 [O]": "51,410.00",
            "TOWER 2 [P]": "18,915.00",
            "TOWER 3 [Q]": "46,075.00",
            "TOWER 4 [R]": "21,825.00",
            "[S]": "TRUE",
            "[T]": "-29585"
          }
        },
        {
          "id": "2 - Main/149-L",
          "item_code": "L",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher; 5.0kg CO2 type",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher; 5.0kg CO2 type",
          "quantity": 476,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 104720,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8380
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "55",
            "Tower 1 [E]": "107",
            "Tower 2 [F]": "95",
            "Tower 3 [G]": "78",
            "Tower 4 [H]": "114",
            "TOTAL QTY [I]": "476",
            "BASEMENTS [M]": "5,940.00",
            "GF & PODIUM [N]": "12,100.00",
            "TOWER 1 [O]": "23,540.00",
            "TOWER 2 [P]": "20,900.00",
            "TOWER 3 [Q]": "17,160.00",
            "TOWER 4 [R]": "25,080.00",
            "[S]": "TRUE",
            "[T]": "1540"
          }
        },
        {
          "id": "2 - Main/149-M",
          "item_code": "M",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher 50 Ltr; trolley type",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher 50 Ltr; trolley type",
          "quantity": 142,
          "unit": "Nr.",
          "rate_aed": 3250,
          "amount_aed": 461500,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8382
          },
          "extra_columns": {
            "Basement [C]": "45",
            "GF & Podium [D]": "39",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "58",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "142",
            "BASEMENTS [M]": "146,250.00",
            "GF & PODIUM [N]": "126,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "188,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/149-N",
          "item_code": "N",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher 12kg; trolley type",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher 12kg; trolley type",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8384
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/149-P",
          "item_code": "P",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher 12kg; CO2 wheeled type",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher 12kg; CO2 wheeled type",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8386
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/149-Q",
          "item_code": "Q",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher; DCP 4.5kg",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher; DCP 4.5kg",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 205,
          "amount_aed": 1435,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8388
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,435.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/149-R",
          "item_code": "R",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher; multi purpose dry powder 2.5kg",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher; multi purpose dry powder 2.5kg",
          "quantity": 1798,
          "unit": "Nr.",
          "rate_aed": 110,
          "amount_aed": 197780,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8390
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "118",
            "Tower 1 [E]": "404",
            "Tower 2 [F]": "413",
            "Tower 3 [G]": "453",
            "Tower 4 [H]": "410",
            "TOTAL QTY [I]": "1,798",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,980.00",
            "TOWER 1 [O]": "44,440.00",
            "TOWER 2 [P]": "45,430.00",
            "TOWER 3 [Q]": "49,830.00",
            "TOWER 4 [R]": "45,100.00",
            "[S]": "TRUE",
            "[T]": "660"
          }
        },
        {
          "id": "2 - Main/149-S",
          "item_code": "S",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Fire extinguisher; dry powder 6kg",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Fire extinguisher; dry powder 6kg",
          "quantity": 83,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 22410,
          "amount_state": "number",
          "printed_page": "2/Q/30",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8392
          },
          "extra_columns": {
            "Basement [C]": "33",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "27",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "8,910.00",
            "GF & PODIUM [N]": "6,210.00",
            "TOWER 1 [O]": "7,290.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7290"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/150",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 4758180,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/150-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Foam type extinguisher 9 Ltr.",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Foam type extinguisher 9 Ltr.",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Gate valve; 40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Gate valve; 40mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 1400,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "700.00",
            "TOWER 2 [P]": "700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-700"
          }
        },
        {
          "id": "2 - Main/150-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Gate valve; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Gate valve; 50mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Gate valve; 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Gate valve; 65mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8415
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Gate valve; 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Gate valve; 150mm diameter",
          "quantity": 90,
          "unit": "Nr.",
          "rate_aed": 2900,
          "amount_aed": 261000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8417
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "30",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "26,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "43,500.00",
            "TOWER 2 [P]": "87,000.00",
            "TOWER 3 [Q]": "55,100.00",
            "TOWER 4 [R]": "49,300.00",
            "[S]": "TRUE",
            "[T]": "5800"
          }
        },
        {
          "id": "2 - Main/150-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Gate valve; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Gate valve; 200mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 3900,
          "amount_aed": 27300,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8419
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "15,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7800"
          }
        },
        {
          "id": "2 - Main/150-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "SIV valve; 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — SIV valve; 150mm diameter",
          "quantity": 58,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 197200,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8421
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "91,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "23,800.00",
            "TOWER 2 [P]": "44,200.00",
            "TOWER 3 [Q]": "10,200.00",
            "TOWER 4 [R]": "27,200.00",
            "[S]": "TRUE",
            "[T]": "3400"
          }
        },
        {
          "id": "2 - Main/150-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Isolation valve; 80mm diameter",
          "quantity": 262,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 209600,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8423
          },
          "extra_columns": {
            "Basement [C]": "36",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "53",
            "Tower 2 [F]": "46",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "56",
            "TOTAL QTY [I]": "262",
            "BASEMENTS [M]": "28,800.00",
            "GF & PODIUM [N]": "28,000.00",
            "TOWER 1 [O]": "42,400.00",
            "TOWER 2 [P]": "36,800.00",
            "TOWER 3 [Q]": "28,800.00",
            "TOWER 4 [R]": "44,800.00",
            "[S]": "TRUE",
            "[T]": "2400"
          }
        },
        {
          "id": "2 - Main/150-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Isolation valve; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Isolation valve; 200mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-K",
          "item_code": "K",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Non - return valve; 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Non - return valve; 65mm diameter",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1473,
          "amount_aed": 10311,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8427
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "1,473.00",
            "GF & PODIUM [N]": "8,838.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-L",
          "item_code": "L",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Non - return valve; 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Non - return valve; 150mm diameter",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 71400,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8429
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "3,400.00",
            "GF & PODIUM [N]": "68,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-M",
          "item_code": "M",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Non - return valve; 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Non - return valve; 200mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 4533,
          "amount_aed": 13599,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8431
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "9,066.00",
            "GF & PODIUM [N]": "4,533.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-N",
          "item_code": "N",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Pre action valve; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Pre action valve; 50mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,000.00",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "6,000.00",
            "TOWER 4 [R]": "6,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-P",
          "item_code": "P",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Pre action valve; 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Pre action valve; 65mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6500,
          "amount_aed": 26000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,500.00",
            "TOWER 2 [P]": "6,500.00",
            "TOWER 3 [Q]": "6,500.00",
            "TOWER 4 [R]": "6,500.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-Q",
          "item_code": "Q",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Deluge valve; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Deluge valve; 50mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-R",
          "item_code": "R",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Foam tank",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Foam tank",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 7500,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/150-S",
          "item_code": "S",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Water flow meter; 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Water flow meter; 150mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7400,
          "amount_aed": 29600,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8441
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "7,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,400.00",
            "[S]": "TRUE",
            "[T]": "7400"
          }
        },
        {
          "id": "2 - Main/150-T",
          "item_code": "T",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Anti vortex plate",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Anti vortex plate",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8443
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,500.00",
            "[S]": "TRUE",
            "[T]": "3500"
          }
        },
        {
          "id": "2 - Main/150-U",
          "item_code": "U",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "Puddle flange",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — Puddle flange",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 1050,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "350.00",
            "[S]": "TRUE",
            "[T]": "350"
          }
        },
        {
          "id": "2 - Main/150-V",
          "item_code": "V",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "1/2\" Upright sprinkler head, (68°c) quick response",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — 1/2\" Upright sprinkler head, (68°c) quick response",
          "quantity": 10887,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 1088700,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8447
          },
          "extra_columns": {
            "Basement [C]": "4,642",
            "GF & Podium [D]": "3,417",
            "Tower 1 [E]": "691",
            "Tower 2 [F]": "703",
            "Tower 3 [G]": "767",
            "Tower 4 [H]": "667",
            "TOTAL QTY [I]": "10,887",
            "BASEMENTS [M]": "464,200.00",
            "GF & PODIUM [N]": "341,700.00",
            "TOWER 1 [O]": "69,100.00",
            "TOWER 2 [P]": "70,300.00",
            "TOWER 3 [Q]": "76,700.00",
            "TOWER 4 [R]": "66,700.00",
            "[S]": "TRUE",
            "[T]": "-2400"
          }
        },
        {
          "id": "2 - Main/150-W",
          "item_code": "W",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "1/2\" Concealed sprinkler head, (68°c) quick response",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — 1/2\" Concealed sprinkler head, (68°c) quick response",
          "quantity": 14568,
          "unit": "Nr.",
          "rate_aed": 190,
          "amount_aed": 2767920,
          "amount_state": "number",
          "printed_page": "2/Q/31",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8449
          },
          "extra_columns": {
            "Basement [C]": "219",
            "GF & Podium [D]": "1,321",
            "Tower 1 [E]": "3,324",
            "Tower 2 [F]": "3,208",
            "Tower 3 [G]": "3,052",
            "Tower 4 [H]": "3,444",
            "TOTAL QTY [I]": "14,568",
            "BASEMENTS [M]": "41,610.00",
            "GF & PODIUM [N]": "250,990.00",
            "TOWER 1 [O]": "631,560.00",
            "TOWER 2 [P]": "609,520.00",
            "TOWER 3 [Q]": "579,880.00",
            "TOWER 4 [R]": "654,360.00",
            "[S]": "TRUE",
            "[T]": "22800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/151",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 2037230,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/151-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "1/2\" Extended sidewall sprinkler,  (68°c) quick response",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — 1/2\" Extended sidewall sprinkler,  (68°c) quick response",
          "quantity": 3007,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 420980,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "126",
            "Tower 1 [E]": "724",
            "Tower 2 [F]": "730",
            "Tower 3 [G]": "727",
            "Tower 4 [H]": "700",
            "TOTAL QTY [I]": "3,007",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,640.00",
            "TOWER 1 [O]": "101,360.00",
            "TOWER 2 [P]": "102,200.00",
            "TOWER 3 [Q]": "101,780.00",
            "TOWER 4 [R]": "98,000.00",
            "[S]": "TRUE",
            "[T]": "-3360"
          }
        },
        {
          "id": "2 - Main/151-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Accessories; including hangers, supports, fixings and all ancillary works as necessary"
          ],
          "own_description": "1/2\" Side wall sprinkler,  (68°c) quick response",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Accessories; including hangers, supports, fixings and all ancillary works as necessary — 1/2\" Side wall sprinkler,  (68°c) quick response",
          "quantity": 2760,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 386400,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8469
          },
          "extra_columns": {
            "Basement [C]": "78",
            "GF & Podium [D]": "264",
            "Tower 1 [E]": "580",
            "Tower 2 [F]": "611",
            "Tower 3 [G]": "629",
            "Tower 4 [H]": "598",
            "TOTAL QTY [I]": "2,760",
            "BASEMENTS [M]": "10,920.00",
            "GF & PODIUM [N]": "36,960.00",
            "TOWER 1 [O]": "81,200.00",
            "TOWER 2 [P]": "85,540.00",
            "TOWER 3 [Q]": "88,060.00",
            "TOWER 4 [R]": "83,720.00",
            "[S]": "TRUE",
            "[T]": "2520"
          }
        },
        {
          "id": "2 - Main/151-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pipe specialties including all fixing materials, fittings, markings and all ancillary works as necessary",
            "Alarm check valve assembly; including system pressure gauge, OS&Y gate valve, retard chamber, main drain valve and alarm check valve"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pipe specialties including all fixing materials, fittings, markings and all ancillary works as necessary — Alarm check valve assembly; including system pressure gauge, OS&Y gate valve, retard chamber, main drain valve and alarm check valve — 200mm diameter",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 12800,
          "amount_aed": 115200,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "51,200.00",
            "TOWER 2 [P]": "38,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "25,600.00",
            "[S]": "TRUE",
            "[T]": "-25600"
          }
        },
        {
          "id": "2 - Main/151-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves — 65mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 5500,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/151-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves — 150mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 12500,
          "amount_aed": 75000,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "25,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "25,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/151-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Pressure reducing valve station PRV assembly; including pressure gauge, four number isolation valves and two number of pressure reducing valves — 200mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 17000,
          "amount_aed": 34000,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/151-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings — 50mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/151-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings — 65mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8489
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "10,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5000"
          }
        },
        {
          "id": "2 - Main/151-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings — 80mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2750,
          "amount_aed": 2750,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/151-K",
          "item_code": "K",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings — 100mm diameter",
          "quantity": 101,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 303000,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8493
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "29",
            "Tower 2 [F]": "38",
            "Tower 3 [G]": "28",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "87,000.00",
            "TOWER 2 [P]": "114,000.00",
            "TOWER 3 [Q]": "84,000.00",
            "TOWER 4 [R]": "15,000.00",
            "[S]": "TRUE",
            "[T]": "-72000"
          }
        },
        {
          "id": "2 - Main/151-L",
          "item_code": "L",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Zone control valve assembly; including control valve with supervisory switch, water flow switch, test master, sight glass and couplings — 150mm diameter",
          "quantity": 196,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 666400,
          "amount_state": "number",
          "printed_page": "2/Q/32",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8495
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "47",
            "Tower 1 [E]": "21",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "17",
            "Tower 4 [H]": "70",
            "TOTAL QTY [I]": "196",
            "BASEMENTS [M]": "91,800.00",
            "GF & PODIUM [N]": "159,800.00",
            "TOWER 1 [O]": "71,400.00",
            "TOWER 2 [P]": "47,600.00",
            "TOWER 3 [Q]": "57,800.00",
            "TOWER 4 [R]": "238,000.00",
            "[S]": "TRUE",
            "[T]": "166600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/152",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 6716400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/152-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary"
          ],
          "own_description": "2 way breeching inlet; filling line",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary — 2 way breeching inlet; filling line",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2800,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/152-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary"
          ],
          "own_description": "2 way breeching inlet; sprinkler line",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary — 2 way breeching inlet; sprinkler line",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2800,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8523
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/152-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary"
          ],
          "own_description": "2 way breeching inlet; wet & fire hydrant",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Breeching Inlet chrome plated; including cap, chain, stainless steel door and frame, wired glass door, fittings and all ancillary works as necessary — 2 way breeching inlet; wet & fire hydrant",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2800,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/152-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire hose-reel cabinet; including 25mm diameter x 30m long automatic fire hose reel with nozzle, pressure reducing valve, lock shield valve, 65mm diameter landing valve with built-in PRV, 65mm diameter x 30m fire hose with adjustable nozzle, 1Nr. 4.5kg dry powder and 1Nr. 5kg CO2 fire extinguisher, stainless steel door, supports, accessories, fittings and all ancillary works as necessary"
          ],
          "own_description": "Fire hose cabinet recessed and surface mounted",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire hose-reel cabinet; including 25mm diameter x 30m long automatic fire hose reel with nozzle, pressure reducing valve, lock shield valve, 65mm diameter landing valve with built-in PRV, 65mm diameter x 30m fire hose with adjustable nozzle, 1Nr. 4.5kg dry powder and 1Nr. 5kg CO2 fire extinguisher, stainless steel door, supports, accessories, fittings and all ancillary works as necessary — Fire hose cabinet recessed and surface mounted",
          "quantity": 492,
          "unit": "Nr.",
          "rate_aed": 11500,
          "amount_aed": 5658000,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8529
          },
          "extra_columns": {
            "Basement [C]": "48",
            "GF & Podium [D]": "83",
            "Tower 1 [E]": "101",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "68",
            "Tower 4 [H]": "106",
            "TOTAL QTY [I]": "492",
            "BASEMENTS [M]": "552,000.00",
            "GF & PODIUM [N]": "954,500.00",
            "TOWER 1 [O]": "1,161,500.00",
            "TOWER 2 [P]": "989,000.00",
            "TOWER 3 [Q]": "782,000.00",
            "TOWER 4 [R]": "1,219,000.00",
            "[S]": "TRUE",
            "[T]": "57500"
          }
        },
        {
          "id": "2 - Main/152-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-BF-FF-EP-01, Electric driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 11bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-BF-FF-EP-01, Electric driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 11bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8533
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "380,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/152-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-P2-FF-EP-02, Electric driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 18.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-P2-FF-EP-02, Electric driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 18.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290000,
          "amount_aed": 290000,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "290,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/152-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T1-29F-FF-DP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 16.2bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T1-29F-FF-DP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 16.2bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/33",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8537
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "380,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-380000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/153",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 1718000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/153-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 14.3bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 14.3bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "380,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-48F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 13.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-48F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 13.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "380,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "380,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T4-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T4-29F-FF-EP-01, Electric driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 380000,
          "amount_aed": 380000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "380,000.00",
            "[S]": "TRUE",
            "[T]": "380000"
          }
        },
        {
          "id": "2 - Main/153-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-BF-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 11bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-BF-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 11bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8569
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "33,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-P2-FF-DP-02, Diesel engine driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 18.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-P2-FF-DP-02, Diesel engine driven fire pump; with estimated flow rate of 1000gpm and duty pump head of 18.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T1-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 16.2bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T1-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 16.2bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "33,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-33000"
          }
        },
        {
          "id": "2 - Main/153-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 14.3bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 14.3bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "33,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-48F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 13.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-48F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 13.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "33,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/153-K",
          "item_code": "K",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-DP-01,Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-DP-01,Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/34",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "33,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/154",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 663400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/154-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-DP-01, Diesel engine driven fire pump; with estimated flow rate of 750gpm and duty pump head of 17.8bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33000,
          "amount_aed": 33000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "33,000.00",
            "[S]": "TRUE",
            "[T]": "33000"
          }
        },
        {
          "id": "2 - Main/154-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-BF-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 11bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-BF-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 11bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8603
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "7,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/154-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-P2-FF-JP-02, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 18.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-P2-FF-JP-02, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 18.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/154-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 16.2bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 16.2bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7000"
          }
        },
        {
          "id": "2 - Main/154-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 14.3bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 14.3bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/154-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T2-48F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 13.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T2-48F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 13.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/154-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T3-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 17.6bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T3-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 17.6bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/154-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary"
          ],
          "own_description": "T4-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 17.8bar",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting pump; including control panels, gages, air vent, flexible connections, strainers, valves, wiring, supports, concrete base, vibration isolators, BMS connection, connection to power supply and all ancillary works as necessary — T4-29F-FF-JP-01, Jockey pump; with estimated flow rate of 10gpm and duty pump head of 17.8bar",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,000.00",
            "[S]": "TRUE",
            "[T]": "7000"
          }
        },
        {
          "id": "2 - Main/154-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting diesel tank; including supports, concrete base and all ancillary works as necessary"
          ],
          "own_description": "Diesel tank; 350US gallon",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting diesel tank; including supports, concrete base and all ancillary works as necessary — Diesel tank; 350US gallon",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 290700,
          "amount_aed": 581400,
          "amount_state": "number",
          "printed_page": "2/Q/35",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "290,700.00",
            "TOWER 2 [P]": "290,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-290700"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/155",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 2964600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/155-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting water tank; including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere)"
          ],
          "own_description": "Fire tank; tank capacity of 227m³",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting water tank; including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere) — Fire tank; tank capacity of 227m³",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 385900,
          "amount_aed": 771800,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8652
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "771,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting water tank; GRP tank, including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere)"
          ],
          "own_description": "Fire tank; tank capacity of 85m³",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting water tank; GRP tank, including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere) — Fire tank; tank capacity of 85m³",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 144500,
          "amount_aed": 867000,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "144,500.00",
            "TOWER 2 [P]": "289,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "433,500.00",
            "[S]": "TRUE",
            "[T]": "289000"
          }
        },
        {
          "id": "2 - Main/155-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire fighting water tank; GRP tank, including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere)"
          ],
          "own_description": "Fire tank; tank capacity of 43m³",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire fighting water tank; GRP tank, including float valve, foot valve  non-return valve, isolation valves, drain valve, water level sensor, pipes, fittings, accessories and all ancillary works as necessary (structure measured elsewhere) — Fire tank; tank capacity of 43m³",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 73100,
          "amount_aed": 146200,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "146,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to MCC room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to MCC room",
          "quantity": 13,
          "unit": "m2",
          "rate_aed": 2500,
          "amount_aed": 32500,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8662
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "32,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to FCC room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to FCC room",
          "quantity": 15,
          "unit": "m2",
          "rate_aed": 2500,
          "amount_aed": 37500,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-F",
          "item_code": "F",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to GSM room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to GSM room",
          "quantity": 15,
          "unit": "m2",
          "rate_aed": 2500,
          "amount_aed": 37500,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-G",
          "item_code": "G",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to LV, CBS/UPS room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to LV, CBS/UPS room",
          "quantity": 400,
          "unit": "m2",
          "rate_aed": 1800,
          "amount_aed": 720000,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "400",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "400",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-H",
          "item_code": "H",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to MTR room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to MTR room",
          "quantity": 38,
          "unit": "m2",
          "rate_aed": 2200,
          "amount_aed": 83600,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "83,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-J",
          "item_code": "J",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to security equipment & GSM room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to security equipment & GSM room",
          "quantity": 63,
          "unit": "m2",
          "rate_aed": 2500,
          "amount_aed": 157500,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "63",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "157,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/155-K",
          "item_code": "K",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary"
          ],
          "own_description": "to generator",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Fire suppression system; including fire extinguishing control panel with optical smoke detector, pipes fittings accessories and all ancillary works as necessary — to generator",
          "quantity": 74,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 111000,
          "amount_state": "number",
          "printed_page": "2/Q/36",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "111,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/156",
      "section": "FIRE PROTECTION SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 131000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/156-A",
          "item_code": "A",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Foam fire suppression; including fire extinguishing control panel with optical smoke detector, ionization smoke detector, manual release unit, abort switch, electrical control head, pressure switch, alarm bell, strobe horn, indicator, nozzle (ceiling void, room void, floor void), cylinder, cylinder nameplate, cylinder valve, liquid level indicator, lifting lugs, and safety cap, pipes fittings accessories and all ancillary works as necessary."
          ],
          "own_description": "to generator room",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Foam fire suppression; including fire extinguishing control panel with optical smoke detector, ionization smoke detector, manual release unit, abort switch, electrical control head, pressure switch, alarm bell, strobe horn, indicator, nozzle (ceiling void, room void, floor void), cylinder, cylinder nameplate, cylinder valve, liquid level indicator, lifting lugs, and safety cap, pipes fittings accessories and all ancillary works as necessary. — to generator room",
          "quantity": 74,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 111000,
          "amount_state": "number",
          "printed_page": "2/Q/37",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "111,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/156-B",
          "item_code": "B",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Tower 1",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary — Tower 1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/37",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8706
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/156-C",
          "item_code": "C",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Tower 2",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary — Tower 2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/37",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8708
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/156-D",
          "item_code": "D",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Tower 3",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary — Tower 3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/37",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8710
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/156-E",
          "item_code": "E",
          "section": "FIRE PROTECTION SYSTEM",
          "heading_path": [
            "Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Tower 4",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — FIRE PROTECTION SYSTEM — Clean agent extinguishing system including hangers, supports, fixings, clean agent pipes, fittings, accessories and all ancillary works as necessary — Tower 4",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/37",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8712
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/157",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 18712210,
      "section_notes": [
        "Note: Refer to the following:"
      ],
      "items": [
        {
          "id": "2 - Main/157-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 20mm diameter",
          "quantity": 67407,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 10111050,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8797
          },
          "extra_columns": {
            "Basement [C]": "1,252",
            "GF & Podium [D]": "3,318",
            "Tower 1 [E]": "15,530",
            "Tower 2 [F]": "15,663",
            "Tower 3 [G]": "16,466",
            "Tower 4 [H]": "15,178",
            "TOTAL QTY [I]": "67,407",
            "BASEMENTS [M]": "187,800.00",
            "GF & PODIUM [N]": "497,700.00",
            "TOWER 1 [O]": "2,329,500.00",
            "TOWER 2 [P]": "2,349,450.00",
            "TOWER 3 [Q]": "2,469,900.00",
            "TOWER 4 [R]": "2,276,700.00",
            "[S]": "TRUE",
            "[T]": "-52800"
          }
        },
        {
          "id": "2 - Main/157-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 25mm diameter",
          "quantity": 5269,
          "unit": "m",
          "rate_aed": 190,
          "amount_aed": 1001110,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8799
          },
          "extra_columns": {
            "Basement [C]": "184",
            "GF & Podium [D]": "538",
            "Tower 1 [E]": "2,040",
            "Tower 2 [F]": "1,256",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1,251",
            "TOTAL QTY [I]": "5,269",
            "BASEMENTS [M]": "34,960.00",
            "GF & PODIUM [N]": "102,220.00",
            "TOWER 1 [O]": "387,600.00",
            "TOWER 2 [P]": "238,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "237,690.00",
            "[S]": "TRUE",
            "[T]": "-149910"
          }
        },
        {
          "id": "2 - Main/157-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 32mm diameter",
          "quantity": 6786,
          "unit": "m",
          "rate_aed": 210,
          "amount_aed": 1425060,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8801
          },
          "extra_columns": {
            "Basement [C]": "31",
            "GF & Podium [D]": "651",
            "Tower 1 [E]": "147",
            "Tower 2 [F]": "1,954",
            "Tower 3 [G]": "1,860",
            "Tower 4 [H]": "2,143",
            "TOTAL QTY [I]": "6,786",
            "BASEMENTS [M]": "6,510.00",
            "GF & PODIUM [N]": "136,710.00",
            "TOWER 1 [O]": "30,870.00",
            "TOWER 2 [P]": "410,340.00",
            "TOWER 3 [Q]": "390,600.00",
            "TOWER 4 [R]": "450,030.00",
            "[S]": "TRUE",
            "[T]": "419160"
          }
        },
        {
          "id": "2 - Main/157-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 40mm diameter",
          "quantity": 4440,
          "unit": "m",
          "rate_aed": 230,
          "amount_aed": 1021200,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "326",
            "Tower 1 [E]": "1,206",
            "Tower 2 [F]": "666",
            "Tower 3 [G]": "1,178",
            "Tower 4 [H]": "1,064",
            "TOTAL QTY [I]": "4,440",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "74,980.00",
            "TOWER 1 [O]": "277,380.00",
            "TOWER 2 [P]": "153,180.00",
            "TOWER 3 [Q]": "270,940.00",
            "TOWER 4 [R]": "244,720.00",
            "[S]": "TRUE",
            "[T]": "-32660"
          }
        },
        {
          "id": "2 - Main/157-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 50mm diameter",
          "quantity": 1461,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 379860,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "162",
            "Tower 1 [E]": "203",
            "Tower 2 [F]": "436",
            "Tower 3 [G]": "302",
            "Tower 4 [H]": "358",
            "TOTAL QTY [I]": "1,461",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,120.00",
            "TOWER 1 [O]": "52,780.00",
            "TOWER 2 [P]": "113,360.00",
            "TOWER 3 [Q]": "78,520.00",
            "TOWER 4 [R]": "93,080.00",
            "[S]": "TRUE",
            "[T]": "40300"
          }
        },
        {
          "id": "2 - Main/157-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 65mm diameter",
          "quantity": 265,
          "unit": "m",
          "rate_aed": 370,
          "amount_aed": 98050,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "99",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "265",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,220.00",
            "TOWER 1 [O]": "21,460.00",
            "TOWER 2 [P]": "36,630.00",
            "TOWER 3 [Q]": "740.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-21460"
          }
        },
        {
          "id": "2 - Main/157-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 80mm diameter",
          "quantity": 324,
          "unit": "m",
          "rate_aed": 420,
          "amount_aed": 136080,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "238",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "324",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "99,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/157-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 100mm diameter",
          "quantity": 966,
          "unit": "m",
          "rate_aed": 520,
          "amount_aed": 502320,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "438",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "251",
            "Tower 3 [G]": "91",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "966",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "227,760.00",
            "TOWER 1 [O]": "48,880.00",
            "TOWER 2 [P]": "130,520.00",
            "TOWER 3 [Q]": "47,320.00",
            "TOWER 4 [R]": "47,840.00",
            "[S]": "TRUE",
            "[T]": "-1040"
          }
        },
        {
          "id": "2 - Main/157-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 125mm diameter",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 650,
          "amount_aed": 5850,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,850.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5850"
          }
        },
        {
          "id": "2 - Main/157-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 150mm diameter",
          "quantity": 180,
          "unit": "m",
          "rate_aed": 820,
          "amount_aed": 147600,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "42",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "180",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,800.00",
            "TOWER 2 [P]": "43,460.00",
            "TOWER 3 [Q]": "34,440.00",
            "TOWER 4 [R]": "36,900.00",
            "[S]": "TRUE",
            "[T]": "4100"
          }
        },
        {
          "id": "2 - Main/157-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 200mm diameter",
          "quantity": 412,
          "unit": "m",
          "rate_aed": 940,
          "amount_aed": 387280,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8817
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "106",
            "Tower 2 [F]": "33",
            "Tower 3 [G]": "193",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "99,640.00",
            "TOWER 2 [P]": "31,020.00",
            "TOWER 3 [Q]": "181,420.00",
            "TOWER 4 [R]": "75,200.00",
            "[S]": "TRUE",
            "[T]": "-24440"
          }
        },
        {
          "id": "2 - Main/157-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 250mm diameter",
          "quantity": 1258,
          "unit": "m",
          "rate_aed": 1100,
          "amount_aed": 1383800,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8819
          },
          "extra_columns": {
            "Basement [C]": "53",
            "GF & Podium [D]": "131",
            "Tower 1 [E]": "175",
            "Tower 2 [F]": "321",
            "Tower 3 [G]": "175",
            "Tower 4 [H]": "403",
            "TOTAL QTY [I]": "1,258",
            "BASEMENTS [M]": "58,300.00",
            "GF & PODIUM [N]": "144,100.00",
            "TOWER 1 [O]": "192,500.00",
            "TOWER 2 [P]": "353,100.00",
            "TOWER 3 [Q]": "192,500.00",
            "TOWER 4 [R]": "443,300.00",
            "[S]": "TRUE",
            "[T]": "250800"
          }
        },
        {
          "id": "2 - Main/157-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 300mm diameter",
          "quantity": 981,
          "unit": "m",
          "rate_aed": 1300,
          "amount_aed": 1275300,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8821
          },
          "extra_columns": {
            "Basement [C]": "777",
            "GF & Podium [D]": "148",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "56",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "981",
            "BASEMENTS [M]": "1,010,100.00",
            "GF & PODIUM [N]": "192,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "72,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/157-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 400mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 400mm diameter",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 1650,
          "amount_aed": 151800,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8823
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "151,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/157-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 500mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 500mm diameter",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 2150,
          "amount_aed": 116100,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8825
          },
          "extra_columns": {
            "Basement [C]": "54",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "116,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/157-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive",
            "Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive",
            "Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive",
            "Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive",
            "Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive",
            "Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive",
            "Chilled water installation",
            "Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary",
            "Schedule 40 seamless black steel pipe"
          ],
          "own_description": "CHW 600mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air conditioned Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-1000 to 1996, TW1-MEC-1040 to 1520, TW2-MEC-1040 to 1600, TW3-MEC-1040 to 1560, TW4-MEC-1040 to 1560; all inclusive — Ventilation Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-3000 to 3570, TW1-MEC-3040 to 3510, TW2-MEC-3040 to 3590, TW3-MEC-3040 to 3550, TW4-MEC-3040 to 3550; all inclusive — Smoke Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-4000 to 4996, TW1-MEC-4040 to 4511, TW2-MEC-4040 to 4600, TW3-MEC-4040 to 4551, TW4-MEC-4040 to 4550; all inclusive — Chilled Water Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-PDM-MEC-2000 to 2996, TW1-MEC-2040 to 2520, TW1-MEC-2040 TO 2520, TW2-MEC-2040 to 2600, TW3-MEC-2040 to 2560, TW4-MEC-2040 to 2560; all inclusive — Typical Apartment Layout Plan Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-9121 to 9342; all inclusive — Schematic Diagram Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-4601 to 4603, 3601 to 3640 and 2601 to 2609; all inclusive — Chilled water installation — Piping installation; including painted support brackets, anchor bolts, u-bolt clamps, sleeves, rubber grommet, galvanized MS angle, vibration isolators, hangers, markings, paintings, and all ancillary works as necessary — Schedule 40 seamless black steel pipe — CHW 600mm diameter",
          "quantity": 215,
          "unit": "m",
          "rate_aed": 2650,
          "amount_aed": 569750,
          "amount_state": "number",
          "printed_page": "2/Q/39",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8827
          },
          "extra_columns": {
            "Basement [C]": "129",
            "GF & Podium [D]": "86",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "215",
            "BASEMENTS [M]": "341,850.00",
            "GF & PODIUM [N]": "227,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/158",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3561309,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/158-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 20mm diameter",
          "quantity": 67407,
          "unit": "m",
          "rate_aed": 30,
          "amount_aed": 2022210,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8851
          },
          "extra_columns": {
            "Basement [C]": "1,252",
            "GF & Podium [D]": "3,318",
            "Tower 1 [E]": "15,530",
            "Tower 2 [F]": "15,663",
            "Tower 3 [G]": "16,466",
            "Tower 4 [H]": "15,178",
            "TOTAL QTY [I]": "67,407",
            "BASEMENTS [M]": "37,560.00",
            "GF & PODIUM [N]": "99,540.00",
            "TOWER 1 [O]": "465,900.00",
            "TOWER 2 [P]": "469,890.00",
            "TOWER 3 [Q]": "493,980.00",
            "TOWER 4 [R]": "455,340.00",
            "[S]": "TRUE",
            "[T]": "-10560"
          }
        },
        {
          "id": "2 - Main/158-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 25mm diameter",
          "quantity": 5269,
          "unit": "m",
          "rate_aed": 41,
          "amount_aed": 216029,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8853
          },
          "extra_columns": {
            "Basement [C]": "184",
            "GF & Podium [D]": "538",
            "Tower 1 [E]": "2,040",
            "Tower 2 [F]": "1,256",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1,251",
            "TOTAL QTY [I]": "5,269",
            "BASEMENTS [M]": "7,544.00",
            "GF & PODIUM [N]": "22,058.00",
            "TOWER 1 [O]": "83,640.00",
            "TOWER 2 [P]": "51,496.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,291.00",
            "[S]": "TRUE",
            "[T]": "-32349"
          }
        },
        {
          "id": "2 - Main/158-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 32mm diameter",
          "quantity": 6786,
          "unit": "m",
          "rate_aed": 43,
          "amount_aed": 291798,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8855
          },
          "extra_columns": {
            "Basement [C]": "31",
            "GF & Podium [D]": "651",
            "Tower 1 [E]": "147",
            "Tower 2 [F]": "1,954",
            "Tower 3 [G]": "1,860",
            "Tower 4 [H]": "2,143",
            "TOTAL QTY [I]": "6,786",
            "BASEMENTS [M]": "1,333.00",
            "GF & PODIUM [N]": "27,993.00",
            "TOWER 1 [O]": "6,321.00",
            "TOWER 2 [P]": "84,022.00",
            "TOWER 3 [Q]": "79,980.00",
            "TOWER 4 [R]": "92,149.00",
            "[S]": "TRUE",
            "[T]": "85828"
          }
        },
        {
          "id": "2 - Main/158-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 40mm diameter",
          "quantity": 4440,
          "unit": "m",
          "rate_aed": 46,
          "amount_aed": 204240,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "326",
            "Tower 1 [E]": "1,206",
            "Tower 2 [F]": "666",
            "Tower 3 [G]": "1,178",
            "Tower 4 [H]": "1,064",
            "TOTAL QTY [I]": "4,440",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,996.00",
            "TOWER 1 [O]": "55,476.00",
            "TOWER 2 [P]": "30,636.00",
            "TOWER 3 [Q]": "54,188.00",
            "TOWER 4 [R]": "48,944.00",
            "[S]": "TRUE",
            "[T]": "-6532"
          }
        },
        {
          "id": "2 - Main/158-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 50mm diameter",
          "quantity": 1461,
          "unit": "m",
          "rate_aed": 51,
          "amount_aed": 74511,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "162",
            "Tower 1 [E]": "203",
            "Tower 2 [F]": "436",
            "Tower 3 [G]": "302",
            "Tower 4 [H]": "358",
            "TOTAL QTY [I]": "1,461",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,262.00",
            "TOWER 1 [O]": "10,353.00",
            "TOWER 2 [P]": "22,236.00",
            "TOWER 3 [Q]": "15,402.00",
            "TOWER 4 [R]": "18,258.00",
            "[S]": "TRUE",
            "[T]": "7905"
          }
        },
        {
          "id": "2 - Main/158-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 65mm diameter",
          "quantity": 265,
          "unit": "m",
          "rate_aed": 65,
          "amount_aed": 17225,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "99",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "265",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,890.00",
            "TOWER 1 [O]": "3,770.00",
            "TOWER 2 [P]": "6,435.00",
            "TOWER 3 [Q]": "130.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3770"
          }
        },
        {
          "id": "2 - Main/158-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 80mm diameter",
          "quantity": 324,
          "unit": "m",
          "rate_aed": 71,
          "amount_aed": 23004,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "238",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "324",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,898.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,106.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/158-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 100mm diameter",
          "quantity": 966,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 82110,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "438",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "251",
            "Tower 3 [G]": "91",
            "Tower 4 [H]": "92",
            "TOTAL QTY [I]": "966",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,230.00",
            "TOWER 1 [O]": "7,990.00",
            "TOWER 2 [P]": "21,335.00",
            "TOWER 3 [Q]": "7,735.00",
            "TOWER 4 [R]": "7,820.00",
            "[S]": "TRUE",
            "[T]": "-170"
          }
        },
        {
          "id": "2 - Main/158-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 125mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 125mm diameter",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 106,
          "amount_aed": 954,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "954.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-954"
          }
        },
        {
          "id": "2 - Main/158-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 150mm diameter",
          "quantity": 180,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "42",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "180",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "6,360.00",
            "TOWER 3 [Q]": "5,040.00",
            "TOWER 4 [R]": "5,400.00",
            "[S]": "TRUE",
            "[T]": "600"
          }
        },
        {
          "id": "2 - Main/158-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 200mm diameter",
          "quantity": 412,
          "unit": "m",
          "rate_aed": 157,
          "amount_aed": 64684,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "106",
            "Tower 2 [F]": "33",
            "Tower 3 [G]": "193",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,642.00",
            "TOWER 2 [P]": "5,181.00",
            "TOWER 3 [Q]": "30,301.00",
            "TOWER 4 [R]": "12,560.00",
            "[S]": "TRUE",
            "[T]": "-4082"
          }
        },
        {
          "id": "2 - Main/158-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 250mm diameter",
          "quantity": 1258,
          "unit": "m",
          "rate_aed": 189,
          "amount_aed": 237762,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8873
          },
          "extra_columns": {
            "Basement [C]": "53",
            "GF & Podium [D]": "131",
            "Tower 1 [E]": "175",
            "Tower 2 [F]": "321",
            "Tower 3 [G]": "175",
            "Tower 4 [H]": "403",
            "TOTAL QTY [I]": "1,258",
            "BASEMENTS [M]": "10,017.00",
            "GF & PODIUM [N]": "24,759.00",
            "TOWER 1 [O]": "33,075.00",
            "TOWER 2 [P]": "60,669.00",
            "TOWER 3 [Q]": "33,075.00",
            "TOWER 4 [R]": "76,167.00",
            "[S]": "TRUE",
            "[T]": "43092"
          }
        },
        {
          "id": "2 - Main/158-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 300mm diameter",
          "quantity": 981,
          "unit": "m",
          "rate_aed": 206,
          "amount_aed": 202086,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8875
          },
          "extra_columns": {
            "Basement [C]": "777",
            "GF & Podium [D]": "148",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "56",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "981",
            "BASEMENTS [M]": "160,062.00",
            "GF & PODIUM [N]": "30,488.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,536.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/158-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 400mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 400mm diameter",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 240,
          "amount_aed": 22080,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8877
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "22,080.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/158-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 500mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 500mm diameter",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 274,
          "amount_aed": 14796,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8879
          },
          "extra_columns": {
            "Basement [C]": "54",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "14,796.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/158-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary"
          ],
          "own_description": "CHW 600mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 50mm thick; including rubber support insert, supports, markings, adhesives, tapes, accessories and all ancillary works as necessary — CHW 600mm diameter",
          "quantity": 215,
          "unit": "m",
          "rate_aed": 308,
          "amount_aed": 66220,
          "amount_state": "number",
          "printed_page": "2/Q/40",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8881
          },
          "extra_columns": {
            "Basement [C]": "129",
            "GF & Podium [D]": "86",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "215",
            "BASEMENTS [M]": "39,732.00",
            "GF & PODIUM [N]": "26,488.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/159",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1277319.8,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/159-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 20mm diameter",
          "quantity": 3485,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 418200,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8904
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "122",
            "Tower 1 [E]": "808",
            "Tower 2 [F]": "826",
            "Tower 3 [G]": "906",
            "Tower 4 [H]": "820",
            "TOTAL QTY [I]": "3,485",
            "BASEMENTS [M]": "360.00",
            "GF & PODIUM [N]": "14,640.00",
            "TOWER 1 [O]": "96,960.00",
            "TOWER 2 [P]": "99,120.00",
            "TOWER 3 [Q]": "108,720.00",
            "TOWER 4 [R]": "98,400.00",
            "[S]": "TRUE",
            "[T]": "1440"
          }
        },
        {
          "id": "2 - Main/159-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 25mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8906
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "450.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "150.00",
            "[S]": "TRUE",
            "[T]": "150"
          }
        },
        {
          "id": "2 - Main/159-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 50mm diameter",
          "quantity": 125,
          "unit": "Nr.",
          "rate_aed": 291,
          "amount_aed": 36375,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "26",
            "TOTAL QTY [I]": "125",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "13,095.00",
            "TOWER 2 [P]": "873.00",
            "TOWER 3 [Q]": "14,841.00",
            "TOWER 4 [R]": "7,566.00",
            "[S]": "TRUE",
            "[T]": "-5529"
          }
        },
        {
          "id": "2 - Main/159-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 65mm diameter",
          "quantity": 45,
          "unit": "Nr.",
          "rate_aed": 941,
          "amount_aed": 42345,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8910
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "941.00",
            "TOWER 2 [P]": "40,463.00",
            "TOWER 3 [Q]": "941.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-941"
          }
        },
        {
          "id": "2 - Main/159-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 100mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1142,
          "amount_aed": 5710,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,284.00",
            "TOWER 2 [P]": "1,142.00",
            "TOWER 3 [Q]": "1,142.00",
            "TOWER 4 [R]": "1,142.00",
            "[S]": "TRUE",
            "[T]": "-1142"
          }
        },
        {
          "id": "2 - Main/159-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "250mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 250mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3540,
          "amount_aed": 14160,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8914
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 300mm diameter",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 4342,
          "amount_aed": 43420,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8916
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "43,420.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Isolation valve"
          ],
          "own_description": "600mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Isolation valve — 600mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9142,
          "amount_aed": 9142,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8918
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "9,142.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 20mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 326.6,
          "amount_aed": 979.8000000000001,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8922
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "979.80",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 25mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 343,
          "amount_aed": 1029,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8924
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "1,029.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 50mm diameter",
          "quantity": 171,
          "unit": "Nr.",
          "rate_aed": 425,
          "amount_aed": 72675,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8926
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "74",
            "TOTAL QTY [I]": "171",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "19,125.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "22,100.00",
            "TOWER 4 [R]": "31,450.00",
            "[S]": "TRUE",
            "[T]": "12325"
          }
        },
        {
          "id": "2 - Main/159-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 65mm diameter",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 1182,
          "amount_aed": 33096,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8928
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,182.00",
            "TOWER 2 [P]": "29,550.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,364.00",
            "[S]": "TRUE",
            "[T]": "1182"
          }
        },
        {
          "id": "2 - Main/159-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 80mm diameter",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 1372,
          "amount_aed": 63112,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8930
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "46",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "63,112.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 100mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2948,
          "amount_aed": 14740,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8932
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,896.00",
            "TOWER 2 [P]": "2,948.00",
            "TOWER 3 [Q]": "2,948.00",
            "TOWER 4 [R]": "2,948.00",
            "[S]": "TRUE",
            "[T]": "-2948"
          }
        },
        {
          "id": "2 - Main/159-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary",
            "Double regulating valve"
          ],
          "own_description": "600mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water accessories; including connections, supports, fixings, fittings, accessories and all ancillary works as necessary — Double regulating valve — 600mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28182,
          "amount_aed": 28182,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8934
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "28,182.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/159-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 20mm diameter",
          "quantity": 3970,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 476400,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8938
          },
          "extra_columns": {
            "Basement [C]": "19",
            "GF & Podium [D]": "232",
            "Tower 1 [E]": "898",
            "Tower 2 [F]": "860",
            "Tower 3 [G]": "1,040",
            "Tower 4 [H]": "921",
            "TOTAL QTY [I]": "3,970",
            "BASEMENTS [M]": "2,280.00",
            "GF & PODIUM [N]": "27,840.00",
            "TOWER 1 [O]": "107,760.00",
            "TOWER 2 [P]": "103,200.00",
            "TOWER 3 [Q]": "124,800.00",
            "TOWER 4 [R]": "110,520.00",
            "[S]": "TRUE",
            "[T]": "2760"
          }
        },
        {
          "id": "2 - Main/159-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 25mm diameter",
          "quantity": 99,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 14850,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8940
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "80",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,550.00",
            "TOWER 1 [O]": "150.00",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-150"
          }
        },
        {
          "id": "2 - Main/159-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 32mm diameter",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 192,
          "amount_aed": 2304,
          "amount_state": "number",
          "printed_page": "2/Q/41",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8942
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "768.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "576.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "960.00",
            "[S]": "TRUE",
            "[T]": "960"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/160",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 8433075,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/160-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 40mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "420.00",
            "[S]": "TRUE",
            "[T]": "420"
          }
        },
        {
          "id": "2 - Main/160-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 50mm diameter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 2520,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,520.00",
            "[S]": "TRUE",
            "[T]": "2520"
          }
        },
        {
          "id": "2 - Main/160-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 65mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 510,
          "amount_aed": 510,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "510.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/160-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Valve package assembly; including gate valves, binder test port, strainer, 2 port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 100mm diameter",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 785,
          "amount_aed": 3925,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,355.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,570.00",
            "[S]": "TRUE",
            "[T]": "1570"
          }
        },
        {
          "id": "2 - Main/160-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 20mm diameter",
          "quantity": 3261,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 8152500,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "1,064",
            "Tower 2 [F]": "685",
            "Tower 3 [G]": "790",
            "Tower 4 [H]": "661",
            "TOTAL QTY [I]": "3,261",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "152,500.00",
            "TOWER 1 [O]": "2,660,000.00",
            "TOWER 2 [P]": "1,712,500.00",
            "TOWER 3 [Q]": "1,975,000.00",
            "TOWER 4 [R]": "1,652,500.00",
            "[S]": "TRUE",
            "[T]": "-1007500"
          }
        },
        {
          "id": "2 - Main/160-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 25mm diameter",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 2600,
          "amount_aed": 119600,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "67,600.00",
            "TOWER 2 [P]": "52,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-67600"
          }
        },
        {
          "id": "2 - Main/160-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 32mm diameter",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2700,
          "amount_aed": 27000,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "27,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/160-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 40mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/160-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 50mm diameter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/160-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 65mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5100,
          "amount_aed": 10200,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10200"
          }
        },
        {
          "id": "2 - Main/160-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete"
          ],
          "own_description": "300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — BTU-cooling meter station; including 3nr. isolation valves, temperature sensor, union, connection to CHWS/R, BMS connections, supports and accessories; complete — 300mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 19200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8982
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "76,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/160-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "FAHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — FAHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete — 50mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10000"
          }
        },
        {
          "id": "2 - Main/160-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete — 20mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/Q/42",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 8990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/161",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1974355,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/161-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete — 32mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-14000"
          }
        },
        {
          "id": "2 - Main/161-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — AHU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, AAV, bypass pipe with valve, drain cock, fixings; complete — 50mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "20,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/161-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "FCU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — FCU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 20mm diameter",
          "quantity": 3659,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included in FCU rates",
          "amount_state": "text",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9017
          },
          "extra_columns": {
            "Basement [C]": "19",
            "GF & Podium [D]": "107",
            "Tower 1 [E]": "898",
            "Tower 2 [F]": "809",
            "Tower 3 [G]": "1,040",
            "Tower 4 [H]": "786",
            "TOTAL QTY [I]": "3,659",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/161-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "FCU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — FCU connection assembly; including gate valves, binder test port, strainer, 2nr. port modulating PICV valve, union, reducers, MAV, bypass pipe with valve, fixings; complete — 25mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included in FCU rates",
          "amount_state": "text",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/161-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T2-GF-PHEX 01 to 06; plate heat exchanger (6 duty); with cold side flow of 77.6l/s and hot side flow of 77.6l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T2-GF-PHEX 01 to 06; plate heat exchanger (6 duty); with cold side flow of 77.6l/s and hot side flow of 77.6l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1477157,
          "amount_aed": 1477157,
          "amount_state": "number",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,477,157.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/161-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T1-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 30.2l/s and hot side flow of 30.2l/s, design pressure of 16bar and maximum fluid pressure drop of 40kPa",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T1-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 30.2l/s and hot side flow of 30.2l/s, design pressure of 16bar and maximum fluid pressure drop of 40kPa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 191624,
          "amount_aed": 191624,
          "amount_state": "number",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "191,624.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-191624"
          }
        },
        {
          "id": "2 - Main/161-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T2-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 42.8l/s and hot side flow of 42.8l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T2-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 42.8l/s and hot side flow of 42.8l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 271574,
          "amount_aed": 271574,
          "amount_state": "number",
          "printed_page": "2/Q/43",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "271,574.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/162",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3227448,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/162-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T3-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 38.2l/s and hot side flow of 38.2l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T3-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 38.2l/s and hot side flow of 38.2l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 242386,
          "amount_aed": 242386,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "242,386.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/162-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T4-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 36.9l/s and hot side flow of 36.9l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T4-29F-PHEX-01 to 02; tertiary heat exchanger; with cold side flow of 36.9l/s and hot side flow of 36.9l/s, design pressure of 20bar and maximum fluid pressure drop of 40kPa",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 234137,
          "amount_aed": 234137,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "234,137.00",
            "[S]": "TRUE",
            "[T]": "234137"
          }
        },
        {
          "id": "2 - Main/162-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T2-B1-SP-01 to 07 secondary chilled water pumps (6 duty 1 standby); horizontal, flexible coupled split cased, centrifugal pump, with estimated 77.6kPa and 40m head, motor power of 67kW each, VSD",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T2-B1-SP-01 to 07 secondary chilled water pumps (6 duty 1 standby); horizontal, flexible coupled split cased, centrifugal pump, with estimated 77.6kPa and 40m head, motor power of 67kW each, VSD",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1512525,
          "amount_aed": 1512525,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9059
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,512,525.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/162-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T1-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 30.2kPa and 40m head, motor power of 26kW each, VSD",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T1-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 30.2kPa and 40m head, motor power of 26kW each, VSD",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 251550,
          "amount_aed": 251550,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "251,550.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-251550"
          }
        },
        {
          "id": "2 - Main/162-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T2-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 42.8kPa and 40m head, motor power of 37kW each, VSD",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T2-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 42.8kPa and 40m head, motor power of 37kW each, VSD",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 357975,
          "amount_aed": 357975,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "357,975.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/162-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T3-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 38.2kPa and 40m head, motor power of 33kW each, VSD",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T3-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 38.2kPa and 40m head, motor power of 33kW each, VSD",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 319275,
          "amount_aed": 319275,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "319,275.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/162-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary",
            "Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary"
          ],
          "own_description": "T4-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 36.9kPa and 40m head, motor power of 32kW each, VSD",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Plant and equipment including hangers, supports, fixings, pipe connections, wire connections, flexible connections and all ancillary works as necessary — Heat exchanger unit complete with valves, dosing pumpset, sensor, controllers and all ancillary works as  necessary — T4-29F-SP-01 to 03 secondary chilled water pumps (2 duty 1 standby); horizontal, flexible coupled, end suction, centrifugal pump, with estimated 36.9kPa and 40m head, motor power of 32kW each, VSD",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 309600,
          "amount_aed": 309600,
          "amount_state": "number",
          "printed_page": "2/Q/44",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "309,600.00",
            "[S]": "TRUE",
            "[T]": "309600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/163",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 396000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/163-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-PU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T1-PU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9096
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-32000"
          }
        },
        {
          "id": "2 - Main/163-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-PU-51F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T1-PU-51F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9098
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-32000"
          }
        },
        {
          "id": "2 - Main/163-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-PU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T2-PU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9100
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "32,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-PU-59F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T2-PU-59F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9102
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "32,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-PU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T3-PU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9104
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "32,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-PU-55F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T3-PU-55F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9106
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "32,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-PU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T4-PU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9108
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "32,000.00",
            "[S]": "TRUE",
            "[T]": "32000"
          }
        },
        {
          "id": "2 - Main/163-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-PU-55F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chilled water pressurization unit; including supports, brackets, connections, fixing materials, accessories and all ancillary works as necessary — T4-PU-55F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9110
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "32,000.00",
            "[S]": "TRUE",
            "[T]": "32000"
          }
        },
        {
          "id": "2 - Main/163-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-CDU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary — T1-CDU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9114
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28000"
          }
        },
        {
          "id": "2 - Main/163-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-CDU-B01-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary — T2-CDU-B01-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9116
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-CDU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary — T2-CDU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9118
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-CDU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary — T3-CDU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9120
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "28,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/163-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-CDU-29F-01",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical dosing unit; including wiring connections to power supply, fixing materials, support and brackets, accessories and all ancillary works as necessary — T4-CDU-29F-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 28000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/Q/45",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9122
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,000.00",
            "[S]": "TRUE",
            "[T]": "28000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/164",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 12179485,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/164-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Conditioning system",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Supply air duct (SAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Conditioning system — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Supply air duct (SAD)",
          "quantity": 40234,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 8449140,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9151
          },
          "extra_columns": {
            "Basement [C]": "254",
            "GF & Podium [D]": "2,894",
            "Tower 1 [E]": "8,924",
            "Tower 2 [F]": "9,526",
            "Tower 3 [G]": "9,535",
            "Tower 4 [H]": "9,101",
            "TOTAL QTY [I]": "40,234",
            "BASEMENTS [M]": "53,340.00",
            "GF & PODIUM [N]": "607,740.00",
            "TOWER 1 [O]": "1,874,040.00",
            "TOWER 2 [P]": "2,000,460.00",
            "TOWER 3 [Q]": "2,002,350.00",
            "TOWER 4 [R]": "1,911,210.00",
            "[S]": "TRUE",
            "[T]": "37170"
          }
        },
        {
          "id": "2 - Main/164-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Conditioning system",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Return air duct (RAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Conditioning system — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Return air duct (RAD)",
          "quantity": 1217,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 255570,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9153
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "385",
            "Tower 1 [E]": "182",
            "Tower 2 [F]": "171",
            "Tower 3 [G]": "212",
            "Tower 4 [H]": "254",
            "TOTAL QTY [I]": "1,217",
            "BASEMENTS [M]": "2,730.00",
            "GF & PODIUM [N]": "80,850.00",
            "TOWER 1 [O]": "38,220.00",
            "TOWER 2 [P]": "35,910.00",
            "TOWER 3 [Q]": "44,520.00",
            "TOWER 4 [R]": "53,340.00",
            "[S]": "TRUE",
            "[T]": "15120"
          }
        },
        {
          "id": "2 - Main/164-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 25mm thick; including adhesives, mastics and coatings, sealants, tapes, field-applied jackets, securements, PVC corner angles, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "Supply air duct (SAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 25mm thick; including adhesives, mastics and coatings, sealants, tapes, field-applied jackets, securements, PVC corner angles, fixing materials, accessories and all ancillary works as necessary — Supply air duct (SAD)",
          "quantity": 33299,
          "unit": "m2",
          "rate_aed": 90,
          "amount_aed": 2996910,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9157
          },
          "extra_columns": {
            "Basement [C]": "264",
            "GF & Podium [D]": "1,207",
            "Tower 1 [E]": "8,232",
            "Tower 2 [F]": "5,812",
            "Tower 3 [G]": "9,145",
            "Tower 4 [H]": "8,639",
            "TOTAL QTY [I]": "33,299",
            "BASEMENTS [M]": "23,760.00",
            "GF & PODIUM [N]": "108,630.00",
            "TOWER 1 [O]": "740,880.00",
            "TOWER 2 [P]": "523,080.00",
            "TOWER 3 [Q]": "823,050.00",
            "TOWER 4 [R]": "777,510.00",
            "[S]": "TRUE",
            "[T]": "36630"
          }
        },
        {
          "id": "2 - Main/164-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible elastomeric insulation 25mm thick; including adhesives, mastics and coatings, sealants, tapes, field-applied jackets, securements, PVC corner angles, fixing materials, accessories and all ancillary works as necessary"
          ],
          "own_description": "Return air duct (RAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible elastomeric insulation 25mm thick; including adhesives, mastics and coatings, sealants, tapes, field-applied jackets, securements, PVC corner angles, fixing materials, accessories and all ancillary works as necessary — Return air duct (RAD)",
          "quantity": 834,
          "unit": "m2",
          "rate_aed": 90,
          "amount_aed": 75060,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9159
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "119",
            "Tower 1 [E]": "180",
            "Tower 2 [F]": "61",
            "Tower 3 [G]": "229",
            "Tower 4 [H]": "235",
            "TOTAL QTY [I]": "834",
            "BASEMENTS [M]": "900.00",
            "GF & PODIUM [N]": "10,710.00",
            "TOWER 1 [O]": "16,200.00",
            "TOWER 2 [P]": "5,490.00",
            "TOWER 3 [Q]": "20,610.00",
            "TOWER 4 [R]": "21,150.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/164-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible duct"
          ],
          "own_description": "150mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible duct — 150mm diameter",
          "quantity": 5036,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 251800,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "319",
            "Tower 1 [E]": "1,253",
            "Tower 2 [F]": "1,058",
            "Tower 3 [G]": "1,331",
            "Tower 4 [H]": "1,075",
            "TOTAL QTY [I]": "5,036",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,950.00",
            "TOWER 1 [O]": "62,650.00",
            "TOWER 2 [P]": "52,900.00",
            "TOWER 3 [Q]": "66,550.00",
            "TOWER 4 [R]": "53,750.00",
            "[S]": "TRUE",
            "[T]": "-8900"
          }
        },
        {
          "id": "2 - Main/164-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible duct"
          ],
          "own_description": "200mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible duct — 200mm diameter",
          "quantity": 1792,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 107520,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9165
          },
          "extra_columns": {
            "Basement [C]": "56",
            "GF & Podium [D]": "200",
            "Tower 1 [E]": "160",
            "Tower 2 [F]": "550",
            "Tower 3 [G]": "355",
            "Tower 4 [H]": "471",
            "TOTAL QTY [I]": "1,792",
            "BASEMENTS [M]": "3,360.00",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "9,600.00",
            "TOWER 2 [P]": "33,000.00",
            "TOWER 3 [Q]": "21,300.00",
            "TOWER 4 [R]": "28,260.00",
            "[S]": "TRUE",
            "[T]": "18660"
          }
        },
        {
          "id": "2 - Main/164-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Flexible duct"
          ],
          "own_description": "300mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Flexible duct — 300mm diameter",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/164-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 150 x 150mm",
          "quantity": 58,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 5220,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/164-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 200 x 150mm",
          "quantity": 361,
          "unit": "Nr.",
          "rate_aed": 105,
          "amount_aed": 37905,
          "amount_state": "number",
          "printed_page": "2/Q/46",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "110",
            "Tower 2 [F]": "101",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "96",
            "TOTAL QTY [I]": "361",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "525.00",
            "TOWER 1 [O]": "11,550.00",
            "TOWER 2 [P]": "10,605.00",
            "TOWER 3 [Q]": "5,145.00",
            "TOWER 4 [R]": "10,080.00",
            "[S]": "TRUE",
            "[T]": "-1470"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/165",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 101310,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/165-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 200 x 200mm",
          "quantity": 350,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "105",
            "Tower 3 [G]": "154",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "350",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "720.00",
            "TOWER 2 [P]": "12,600.00",
            "TOWER 3 [Q]": "18,480.00",
            "TOWER 4 [R]": "9,000.00",
            "[S]": "TRUE",
            "[T]": "8280"
          }
        },
        {
          "id": "2 - Main/165-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 250 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 120,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-120"
          }
        },
        {
          "id": "2 - Main/165-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 135,
          "amount_aed": 135,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "135.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 120,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 150mm",
          "quantity": 131,
          "unit": "Nr.",
          "rate_aed": 135,
          "amount_aed": 17685,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "85",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "28",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,485.00",
            "TOWER 1 [O]": "11,475.00",
            "TOWER 2 [P]": "675.00",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "3,780.00",
            "[S]": "TRUE",
            "[T]": "-7695"
          }
        },
        {
          "id": "2 - Main/165-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 200mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9207
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "300.00",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 165,
          "amount_aed": 330,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "330.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 150mm",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 2850,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9211
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "300.00",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "300.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "450.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-300"
          }
        },
        {
          "id": "2 - Main/165-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 165,
          "amount_aed": 330,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 165,
          "amount_aed": 660,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9217
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "330.00",
            "GF & PODIUM [N]": "165.00",
            "TOWER 1 [O]": "165.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-165"
          }
        },
        {
          "id": "2 - Main/165-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 200mm",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 4680,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9219
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "360.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 195,
          "amount_aed": 390,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9221
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "390.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 150mm",
          "quantity": 92,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 16560,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9223
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "82",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "1,080.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,760.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "-14400"
          }
        },
        {
          "id": "2 - Main/165-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 200mm",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 195,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9225
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 195,
          "amount_aed": 390,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9227
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "390.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9229
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "420.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 200mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 1350,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9231
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "450.00",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 200mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9233
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "960.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9237
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "480.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/165-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/47",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/166",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 134775,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/166-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 150mm",
          "quantity": 277,
          "unit": "Nr.",
          "rate_aed": 255,
          "amount_aed": 70635,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9255
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "102",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "98",
            "TOTAL QTY [I]": "277",
            "BASEMENTS [M]": "1,530.00",
            "GF & PODIUM [N]": "5,100.00",
            "TOWER 1 [O]": "255.00",
            "TOWER 2 [P]": "26,010.00",
            "TOWER 3 [Q]": "12,750.00",
            "TOWER 4 [R]": "24,990.00",
            "[S]": "TRUE",
            "[T]": "24735"
          }
        },
        {
          "id": "2 - Main/166-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 285,
          "amount_aed": 570,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9257
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "570.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "720.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-720"
          }
        },
        {
          "id": "2 - Main/166-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 750 x 150mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9261
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "540.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 285,
          "amount_aed": 570,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9263
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "570.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 250mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "850 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 850 x 250mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1000 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1000 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1100 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1100 x 600mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 510,
          "amount_aed": 1020,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1150 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1150 x 450mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 1440,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "960.00",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE",
            "[T]": "480"
          }
        },
        {
          "id": "2 - Main/166-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 200 x 150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 770,
          "amount_aed": 3080,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 250 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 880,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 300 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 1100,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 400 x 150mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1210,
          "amount_aed": 3630,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,630.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3630"
          }
        },
        {
          "id": "2 - Main/166-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 400 x 200mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1320,
          "amount_aed": 5280,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,280.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "500 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 500 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1760,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "650 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 650 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2090,
          "amount_aed": 4180,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 700 x 150mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1870,
          "amount_aed": 9350,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,740.00",
            "TOWER 1 [O]": "1,870.00",
            "TOWER 2 [P]": "3,740.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1870"
          }
        },
        {
          "id": "2 - Main/166-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "700 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 700 x 300mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2200,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "750 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 750 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 2530,
          "amount_aed": 7590,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,590.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/166-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 800 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2090,
          "amount_aed": 4180,
          "amount_state": "number",
          "printed_page": "2/Q/48",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9297
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "4,180.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/167",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 597816,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/167-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "850 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 850 x 300mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2530,
          "amount_aed": 12650,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1000 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1000 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2970,
          "amount_aed": 2970,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1100 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1100 x 500mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 31680,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "17,600.00",
            "TOWER 2 [P]": "10,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17600"
          }
        },
        {
          "id": "2 - Main/167-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1150 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1150 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3190,
          "amount_aed": 6380,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1500 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3630,
          "amount_aed": 7260,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1600 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1600 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4620,
          "amount_aed": 4620,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1700 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1700 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4400,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "1750 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 1750 x 200mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4290,
          "amount_aed": 17160,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "2000 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 2000 x 300mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 5060,
          "amount_aed": 30360,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized smoke fire damper (MSFD)"
          ],
          "own_description": "2250 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized smoke fire damper (MSFD) — 2250 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5610,
          "amount_aed": 5610,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "100 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 100 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 56,
          "amount_aed": 56,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "56.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "150 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 150 x 100mm",
          "quantity": 532,
          "unit": "Nr.",
          "rate_aed": 70,
          "amount_aed": 37240,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "370",
            "Tower 2 [F]": "26",
            "Tower 3 [G]": "120",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "532",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "210.00",
            "TOWER 1 [O]": "25,900.00",
            "TOWER 2 [P]": "1,820.00",
            "TOWER 3 [Q]": "8,400.00",
            "TOWER 4 [R]": "910.00",
            "[S]": "TRUE",
            "[T]": "-24990"
          }
        },
        {
          "id": "2 - Main/167-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 150 x 150mm",
          "quantity": 3046,
          "unit": "Nr.",
          "rate_aed": 84,
          "amount_aed": 255864,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9339
          },
          "extra_columns": {
            "Basement [C]": "28",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "590",
            "Tower 2 [F]": "765",
            "Tower 3 [G]": "804",
            "Tower 4 [H]": "680",
            "TOTAL QTY [I]": "3,046",
            "BASEMENTS [M]": "2,352.00",
            "GF & PODIUM [N]": "15,036.00",
            "TOWER 1 [O]": "49,560.00",
            "TOWER 2 [P]": "64,260.00",
            "TOWER 3 [Q]": "67,536.00",
            "TOWER 4 [R]": "57,120.00",
            "[S]": "TRUE",
            "[T]": "7560"
          }
        },
        {
          "id": "2 - Main/167-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 100mm",
          "quantity": 56,
          "unit": "Nr.",
          "rate_aed": 84,
          "amount_aed": 4704,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "14",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,176.00",
            "TOWER 2 [P]": "1,176.00",
            "TOWER 3 [Q]": "1,176.00",
            "TOWER 4 [R]": "1,176.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 150mm",
          "quantity": 595,
          "unit": "Nr.",
          "rate_aed": 98,
          "amount_aed": 58310,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9343
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "90",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "393",
            "TOTAL QTY [I]": "595",
            "BASEMENTS [M]": "392.00",
            "GF & PODIUM [N]": "8,820.00",
            "TOWER 1 [O]": "4,508.00",
            "TOWER 2 [P]": "5,194.00",
            "TOWER 3 [Q]": "882.00",
            "TOWER 4 [R]": "38,514.00",
            "[S]": "TRUE",
            "[T]": "34006"
          }
        },
        {
          "id": "2 - Main/167-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 100mm",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 84,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "84.00",
            "TOWER 2 [P]": "1,596.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-84"
          }
        },
        {
          "id": "2 - Main/167-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 200mm",
          "quantity": 544,
          "unit": "Nr.",
          "rate_aed": 112,
          "amount_aed": 60928,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "395",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "69",
            "TOTAL QTY [I]": "544",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,464.00",
            "TOWER 1 [O]": "560.00",
            "TOWER 2 [P]": "44,240.00",
            "TOWER 3 [Q]": "5,936.00",
            "TOWER 4 [R]": "7,728.00",
            "[S]": "TRUE",
            "[T]": "7168"
          }
        },
        {
          "id": "2 - Main/167-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 100mm",
          "quantity": 80,
          "unit": "Nr.",
          "rate_aed": 98,
          "amount_aed": 7840,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9349
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "20",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "80",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,960.00",
            "TOWER 2 [P]": "1,960.00",
            "TOWER 3 [Q]": "1,960.00",
            "TOWER 4 [R]": "1,960.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 150mm",
          "quantity": 372,
          "unit": "Nr.",
          "rate_aed": 112,
          "amount_aed": 41664,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9351
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "89",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "226",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "372",
            "BASEMENTS [M]": "336.00",
            "GF & PODIUM [N]": "9,968.00",
            "TOWER 1 [O]": "2,016.00",
            "TOWER 2 [P]": "2,016.00",
            "TOWER 3 [Q]": "25,312.00",
            "TOWER 4 [R]": "2,016.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/167-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 200mm",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 126,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9353
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "2,016.00",
            "GF & PODIUM [N]": "2,394.00",
            "TOWER 1 [O]": "882.00",
            "TOWER 2 [P]": "504.00",
            "TOWER 3 [Q]": "252.00",
            "TOWER 4 [R]": "252.00",
            "[S]": "TRUE",
            "[T]": "-630"
          }
        },
        {
          "id": "2 - Main/167-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 140,
          "amount_state": "number",
          "printed_page": "2/Q/49",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9355
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "140.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-140"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/168",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 280686,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/168-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 112,
          "amount_aed": 112,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9371
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "112.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 150mm",
          "quantity": 355,
          "unit": "Nr.",
          "rate_aed": 126,
          "amount_aed": 44730,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9373
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "88",
            "Tower 3 [G]": "101",
            "Tower 4 [H]": "89",
            "TOTAL QTY [I]": "355",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,032.00",
            "TOWER 1 [O]": "5,670.00",
            "TOWER 2 [P]": "11,088.00",
            "TOWER 3 [Q]": "12,726.00",
            "TOWER 4 [R]": "11,214.00",
            "[S]": "TRUE",
            "[T]": "5544"
          }
        },
        {
          "id": "2 - Main/168-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 200mm",
          "quantity": 782,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 109480,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9375
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "168",
            "Tower 3 [G]": "201",
            "Tower 4 [H]": "177",
            "TOTAL QTY [I]": "782",
            "BASEMENTS [M]": "2,100.00",
            "GF & PODIUM [N]": "6,020.00",
            "TOWER 1 [O]": "24,920.00",
            "TOWER 2 [P]": "23,520.00",
            "TOWER 3 [Q]": "28,140.00",
            "TOWER 4 [R]": "24,780.00",
            "[S]": "TRUE",
            "[T]": "-140"
          }
        },
        {
          "id": "2 - Main/168-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 250mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 154,
          "amount_aed": 462,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9377
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "154.00",
            "GF & PODIUM [N]": "308.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 150mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 980,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "140.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 200mm",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 154,
          "amount_aed": 2310,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9381
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "154.00",
            "GF & PODIUM [N]": "2,156.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 250mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 1344,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9383
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "840.00",
            "GF & PODIUM [N]": "504.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 154,
          "amount_aed": 308,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "154.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "154.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 200mm",
          "quantity": 132,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 22176,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9387
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "27",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "132",
            "BASEMENTS [M]": "336.00",
            "GF & PODIUM [N]": "1,008.00",
            "TOWER 1 [O]": "7,560.00",
            "TOWER 2 [P]": "4,536.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,736.00",
            "[S]": "TRUE",
            "[T]": "1176"
          }
        },
        {
          "id": "2 - Main/168-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 250mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 728,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9389
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "182.00",
            "GF & PODIUM [N]": "546.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 336,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9391
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "168.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "168.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 546,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "546.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 250mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 980,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9395
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "196.00",
            "GF & PODIUM [N]": "588.00",
            "TOWER 1 [O]": "196.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-196"
          }
        },
        {
          "id": "2 - Main/168-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 150mm",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 8918,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "546.00",
            "TOWER 1 [O]": "8,372.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8372"
          }
        },
        {
          "id": "2 - Main/168-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 392,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "392.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 250mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 1890,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,890.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 392,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "392.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 250mm",
          "quantity": 369,
          "unit": "Nr.",
          "rate_aed": 224,
          "amount_aed": 82656,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "369",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,016.00",
            "TOWER 1 [O]": "19,712.00",
            "TOWER 2 [P]": "18,816.00",
            "TOWER 3 [Q]": "22,400.00",
            "TOWER 4 [R]": "19,712.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 476,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "476.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 504,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "504.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 700 x 150mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 714,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "714.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/168-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 252,
          "amount_state": "number",
          "printed_page": "2/Q/50",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "252.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/169",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 119010,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/169-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 250mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "800 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 800 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 294,
          "amount_aed": 588,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "588.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 672,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "336.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "336.00",
            "[S]": "TRUE",
            "[T]": "336"
          }
        },
        {
          "id": "2 - Main/169-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 150 x 150mm",
          "quantity": 81,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 6480,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9439
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "67",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "81",
            "BASEMENTS [M]": "80.00",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "5,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5360"
          }
        },
        {
          "id": "2 - Main/169-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "225 x 225mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 225 x 225mm",
          "quantity": 403,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 48360,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9441
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "109",
            "Tower 3 [G]": "56",
            "Tower 4 [H]": "104",
            "TOTAL QTY [I]": "403",
            "BASEMENTS [M]": "960.00",
            "GF & PODIUM [N]": "6,720.00",
            "TOWER 1 [O]": "8,400.00",
            "TOWER 2 [P]": "13,080.00",
            "TOWER 3 [Q]": "6,720.00",
            "TOWER 4 [R]": "12,480.00",
            "[S]": "TRUE",
            "[T]": "4080"
          }
        },
        {
          "id": "2 - Main/169-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 120,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9443
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 250 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 240,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "120.00",
            "[S]": "TRUE",
            "[T]": "120"
          }
        },
        {
          "id": "2 - Main/169-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 300 x 300mm",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9447
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "1,120.00",
            "GF & PODIUM [N]": "1,760.00",
            "TOWER 1 [O]": "320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-320"
          }
        },
        {
          "id": "2 - Main/169-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 450 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 1150,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9449
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "230.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "500 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 500 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9451
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "210.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply diffuser (SD)"
          ],
          "own_description": "600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply diffuser (SD) — 600 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9453
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 150 x 150mm",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 2480,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9457
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "23",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "80.00",
            "GF & PODIUM [N]": "480.00",
            "TOWER 1 [O]": "1,840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1840"
          }
        },
        {
          "id": "2 - Main/169-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "225 x 225mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 225 x 225mm",
          "quantity": 402,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 48240,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9459
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "69",
            "Tower 2 [F]": "91",
            "Tower 3 [G]": "106",
            "Tower 4 [H]": "84",
            "TOTAL QTY [I]": "402",
            "BASEMENTS [M]": "960.00",
            "GF & PODIUM [N]": "5,280.00",
            "TOWER 1 [O]": "8,280.00",
            "TOWER 2 [P]": "10,920.00",
            "TOWER 3 [Q]": "12,720.00",
            "TOWER 4 [R]": "10,080.00",
            "[S]": "TRUE",
            "[T]": "1800"
          }
        },
        {
          "id": "2 - Main/169-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 120,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 300 x 300mm",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9463
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "1,120.00",
            "GF & PODIUM [N]": "1,760.00",
            "TOWER 1 [O]": "320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-320"
          }
        },
        {
          "id": "2 - Main/169-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 450 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 1150,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "230.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/169-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 500 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/51",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/170",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 472370,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/170-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "500 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 500 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "210.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return diffuser (RD)"
          ],
          "own_description": "600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return diffuser (RD) — 600 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 200 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 160,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 200 x 200mm",
          "quantity": 104,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "400.00",
            "TOWER 1 [O]": "100.00",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "400.00",
            "TOWER 4 [R]": "4,500.00",
            "[S]": "TRUE",
            "[T]": "4400"
          }
        },
        {
          "id": "2 - Main/170-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 250 x 150mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "200.00",
            "[S]": "TRUE",
            "[T]": "200"
          }
        },
        {
          "id": "2 - Main/170-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 300 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9499
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "120.00",
            "GF & PODIUM [N]": "120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 300 x 150mm",
          "quantity": 59,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 7080,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9501
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "59",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "120.00",
            "TOWER 1 [O]": "480.00",
            "TOWER 2 [P]": "120.00",
            "TOWER 3 [Q]": "6,120.00",
            "TOWER 4 [R]": "240.00",
            "[S]": "TRUE",
            "[T]": "-240"
          }
        },
        {
          "id": "2 - Main/170-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 350 x 150mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9503
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "130.00",
            "GF & PODIUM [N]": "910.00",
            "TOWER 1 [O]": "130.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "130.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-130"
          }
        },
        {
          "id": "2 - Main/170-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 400 x 150mm",
          "quantity": 374,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 52360,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9505
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "374",
            "BASEMENTS [M]": "140.00",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "12,320.00",
            "TOWER 2 [P]": "11,900.00",
            "TOWER 3 [Q]": "14,000.00",
            "TOWER 4 [R]": "12,320.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 400 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 280,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9507
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "140.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "140.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "450 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 450 x 150mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9509
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "480.00",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "160.00",
            "TOWER 3 [Q]": "160.00",
            "TOWER 4 [R]": "160.00",
            "[S]": "TRUE",
            "[T]": "160"
          }
        },
        {
          "id": "2 - Main/170-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 500 x 150mm",
          "quantity": 1616,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 274720,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9511
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "266",
            "Tower 2 [F]": "436",
            "Tower 3 [G]": "453",
            "Tower 4 [H]": "418",
            "TOTAL QTY [I]": "1,616",
            "BASEMENTS [M]": "170.00",
            "GF & PODIUM [N]": "7,140.00",
            "TOWER 1 [O]": "45,220.00",
            "TOWER 2 [P]": "74,120.00",
            "TOWER 3 [Q]": "77,010.00",
            "TOWER 4 [R]": "71,060.00",
            "[S]": "TRUE",
            "[T]": "25840"
          }
        },
        {
          "id": "2 - Main/170-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "500 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 500 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 170,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9513
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "550 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 550 x 150mm",
          "quantity": 244,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 43920,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "244",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "16,200.00",
            "TOWER 2 [P]": "8,100.00",
            "TOWER 3 [Q]": "9,540.00",
            "TOWER 4 [R]": "8,280.00",
            "[S]": "TRUE",
            "[T]": "-7920"
          }
        },
        {
          "id": "2 - Main/170-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "550 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 550 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9517
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "180.00",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "550 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 550 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 180,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9519
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "180.00",
            "[S]": "TRUE",
            "[T]": "180"
          }
        },
        {
          "id": "2 - Main/170-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "600 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 600 x 150mm",
          "quantity": 370,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 74000,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "113",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "370",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "9,200.00",
            "TOWER 2 [P]": "22,600.00",
            "TOWER 3 [Q]": "20,400.00",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE",
            "[T]": "10800"
          }
        },
        {
          "id": "2 - Main/170-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "600 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 600 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9523
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "600 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 600 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/170-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "650 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 650 x 150mm",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 2730,
          "amount_state": "number",
          "printed_page": "2/Q/52",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9527
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "210.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "630.00",
            "TOWER 2 [P]": "630.00",
            "TOWER 3 [Q]": "630.00",
            "TOWER 4 [R]": "630.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/171",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 59350,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/171-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 700 x 150mm",
          "quantity": 186,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 40920,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9543
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "51",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "26",
            "TOTAL QTY [I]": "186",
            "BASEMENTS [M]": "660.00",
            "GF & PODIUM [N]": "2,420.00",
            "TOWER 1 [O]": "9,900.00",
            "TOWER 2 [P]": "11,220.00",
            "TOWER 3 [Q]": "11,000.00",
            "TOWER 4 [R]": "5,720.00",
            "[S]": "TRUE",
            "[T]": "-4180"
          }
        },
        {
          "id": "2 - Main/171-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "700 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 700 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 440,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "220.00",
            "TOWER 2 [P]": "220.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-220"
          }
        },
        {
          "id": "2 - Main/171-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 750 x 150mm",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "750.00",
            "TOWER 2 [P]": "1,000.00",
            "TOWER 3 [Q]": "1,000.00",
            "TOWER 4 [R]": "1,000.00",
            "[S]": "TRUE",
            "[T]": "250"
          }
        },
        {
          "id": "2 - Main/171-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "750 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 750 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 800 x 150mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9551
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "520.00",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "520.00",
            "TOWER 2 [P]": "520.00",
            "TOWER 3 [Q]": "520.00",
            "TOWER 4 [R]": "520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "800 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 800 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9553
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "850 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 850 x 300mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "950 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 950 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1000 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 280,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1000 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1000 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1050 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1050 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 560,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1100 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1100 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 290,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "290.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-290"
          }
        },
        {
          "id": "2 - Main/171-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1100 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1100 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 290,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "290.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-290"
          }
        },
        {
          "id": "2 - Main/171-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1100 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1100 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 580,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "290.00",
            "TOWER 4 [R]": "290.00",
            "[S]": "TRUE",
            "[T]": "290"
          }
        },
        {
          "id": "2 - Main/171-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1100 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1100 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 290,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "290.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1100 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1100 x 600mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1150 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1150 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 1020,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1150 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1150 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1150 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1150 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "340.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "340.00",
            "[S]": "TRUE",
            "[T]": "340"
          }
        },
        {
          "id": "2 - Main/171-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1150 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1150 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "340.00",
            "[S]": "TRUE",
            "[T]": "340"
          }
        },
        {
          "id": "2 - Main/171-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1500 x 50mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 440,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/171-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1500 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 440,
          "amount_aed": 440,
          "amount_state": "number",
          "printed_page": "2/Q/53",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/172",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 167595,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/172-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "1750 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 1750 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 520,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "2000 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 2000 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 615,
          "amount_aed": 1845,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,845.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "2700 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 2700 x 100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 750,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "3000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 3000 x 50mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 820,
          "amount_aed": 1640,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply register"
          ],
          "own_description": "3000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply register — 3000 x 100mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 820,
          "amount_aed": 9020,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply grille"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply grille — 150 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 270,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9613
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "270.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply grille"
          ],
          "own_description": "225 x 225mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply grille — 225 x 225mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9615
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply grille"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply grille — 300 x 300mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9617
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 250 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 200 x 200mm",
          "quantity": 104,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9623
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "52",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,200.00",
            "TOWER 3 [Q]": "400.00",
            "TOWER 4 [R]": "4,500.00",
            "[S]": "TRUE",
            "[T]": "4500"
          }
        },
        {
          "id": "2 - Main/172-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 250 x 150mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9625
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "200.00",
            "TOWER 3 [Q]": "200.00",
            "TOWER 4 [R]": "200.00",
            "[S]": "TRUE",
            "[T]": "200"
          }
        },
        {
          "id": "2 - Main/172-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 120,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9627
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 300 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 260,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9629
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "130.00",
            "GF & PODIUM [N]": "130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 300 x 150mm",
          "quantity": 99,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 12870,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9631
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "130.00",
            "TOWER 1 [O]": "5,590.00",
            "TOWER 2 [P]": "260.00",
            "TOWER 3 [Q]": "6,630.00",
            "TOWER 4 [R]": "260.00",
            "[S]": "TRUE",
            "[T]": "-5330"
          }
        },
        {
          "id": "2 - Main/172-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 350 x 150mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9633
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "130.00",
            "GF & PODIUM [N]": "910.00",
            "TOWER 1 [O]": "130.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "130.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-130"
          }
        },
        {
          "id": "2 - Main/172-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 400 x 150mm",
          "quantity": 550,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 77000,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9635
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "153",
            "Tower 3 [G]": "151",
            "Tower 4 [H]": "142",
            "TOTAL QTY [I]": "550",
            "BASEMENTS [M]": "140.00",
            "GF & PODIUM [N]": "1,820.00",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "21,420.00",
            "TOWER 3 [Q]": "21,140.00",
            "TOWER 4 [R]": "19,880.00",
            "[S]": "TRUE",
            "[T]": "7280"
          }
        },
        {
          "id": "2 - Main/172-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 400 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 150,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9637
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/172-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "450 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 450 x 150mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9639
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "480.00",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "160.00",
            "TOWER 3 [Q]": "160.00",
            "TOWER 4 [R]": "160.00",
            "[S]": "TRUE",
            "[T]": "160"
          }
        },
        {
          "id": "2 - Main/172-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 500 x 50mm",
          "quantity": 42,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 6720,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9641
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "1,280.00",
            "GF & PODIUM [N]": "2,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "2,560.00",
            "[S]": "TRUE",
            "[T]": "2560"
          }
        },
        {
          "id": "2 - Main/172-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "500 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 500 x 100mm",
          "quantity": 210,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 35700,
          "amount_state": "number",
          "printed_page": "2/Q/54",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9643
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "168",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "210",
            "BASEMENTS [M]": "2,720.00",
            "GF & PODIUM [N]": "2,380.00",
            "TOWER 1 [O]": "28,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28560"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/173",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 456850,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/173-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 500 x 150mm",
          "quantity": 1481,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 251770,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9659
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "80",
            "Tower 1 [E]": "400",
            "Tower 2 [F]": "323",
            "Tower 3 [G]": "351",
            "Tower 4 [H]": "318",
            "TOTAL QTY [I]": "1,481",
            "BASEMENTS [M]": "1,530.00",
            "GF & PODIUM [N]": "13,600.00",
            "TOWER 1 [O]": "68,000.00",
            "TOWER 2 [P]": "54,910.00",
            "TOWER 3 [Q]": "59,670.00",
            "TOWER 4 [R]": "54,060.00",
            "[S]": "TRUE",
            "[T]": "-13940"
          }
        },
        {
          "id": "2 - Main/173-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "500 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 500 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 170,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9661
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "550 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 550 x 150mm",
          "quantity": 200,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 36000,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "55",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,440.00",
            "TOWER 1 [O]": "8,280.00",
            "TOWER 2 [P]": "8,100.00",
            "TOWER 3 [Q]": "9,900.00",
            "TOWER 4 [R]": "8,280.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "550 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 550 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9665
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "180.00",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "550 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 550 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 230,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "230.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "600 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 600 x 150mm",
          "quantity": 545,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 109000,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9669
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "153",
            "Tower 3 [G]": "151",
            "Tower 4 [H]": "142",
            "TOTAL QTY [I]": "545",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,200.00",
            "TOWER 1 [O]": "17,600.00",
            "TOWER 2 [P]": "30,600.00",
            "TOWER 3 [Q]": "30,200.00",
            "TOWER 4 [R]": "28,400.00",
            "[S]": "TRUE",
            "[T]": "10800"
          }
        },
        {
          "id": "2 - Main/173-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "600 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 600 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9671
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "600 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 600 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9673
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "650 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 650 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9675
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "210.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 700 x 150mm",
          "quantity": 206,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 45320,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9677
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "52",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "47",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "660.00",
            "GF & PODIUM [N]": "2,200.00",
            "TOWER 1 [O]": "9,680.00",
            "TOWER 2 [P]": "11,440.00",
            "TOWER 3 [Q]": "11,000.00",
            "TOWER 4 [R]": "10,340.00",
            "[S]": "TRUE",
            "[T]": "660"
          }
        },
        {
          "id": "2 - Main/173-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "700 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 700 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 440,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9679
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "220.00",
            "TOWER 2 [P]": "220.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-220"
          }
        },
        {
          "id": "2 - Main/173-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 750 x 150mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "240.00",
            "TOWER 2 [P]": "480.00",
            "TOWER 3 [Q]": "480.00",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE",
            "[T]": "240"
          }
        },
        {
          "id": "2 - Main/173-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "750 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 750 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 800 x 150mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9685
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "500.00",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "500.00",
            "TOWER 2 [P]": "500.00",
            "TOWER 3 [Q]": "500.00",
            "TOWER 4 [R]": "500.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "850 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 850 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "950 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 950 x 150mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "270.00",
            "TOWER 2 [P]": "270.00",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "270.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1000 x 50mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 280,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1000 x 100mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "560.00",
            "TOWER 1 [O]": "280.00",
            "TOWER 2 [P]": "280.00",
            "TOWER 3 [Q]": "280.00",
            "TOWER 4 [R]": "280.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1000 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1000 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 290,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "290.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1000 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1000 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 1020,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1050 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1050 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/173-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1100 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1100 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/Q/55",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "340.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-340"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/174",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 44230,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/174-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1100 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1100 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "350.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-350"
          }
        },
        {
          "id": "2 - Main/174-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1100 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1100 x 400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "350.00",
            "[S]": "TRUE",
            "[T]": "350"
          }
        },
        {
          "id": "2 - Main/174-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1100 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1100 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1100 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1100 x 600mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9723
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1150 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1150 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-360"
          }
        },
        {
          "id": "2 - Main/174-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1150 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1150 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 390,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "390.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1150 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1150 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "400.00",
            "[S]": "TRUE",
            "[T]": "400"
          }
        },
        {
          "id": "2 - Main/174-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1150 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1150 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "420.00",
            "TOWER 4 [R]": "420.00",
            "[S]": "TRUE",
            "[T]": "420"
          }
        },
        {
          "id": "2 - Main/174-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1400 x 150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "450.00",
            "TOWER 2 [P]": "450.00",
            "TOWER 3 [Q]": "450.00",
            "TOWER 4 [R]": "450.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1500 x 50mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1500 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1600 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1600 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 510,
          "amount_aed": 510,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9739
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "510.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1700 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1700 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9741
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "1750 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 1750 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9743
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "2000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 2000 x 100mm",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 620,
          "amount_aed": 11160,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9745
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,240.00",
            "TOWER 1 [O]": "2,480.00",
            "TOWER 2 [P]": "2,480.00",
            "TOWER 3 [Q]": "2,480.00",
            "TOWER 4 [R]": "2,480.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "2000 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 2000 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 620,
          "amount_aed": 1860,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9747
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "2250 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 2250 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9749
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "2500 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 2500 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 780,
          "amount_aed": 780,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "2700 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 2700 x 100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 790,
          "amount_aed": 3160,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9753
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "3000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 3000 x 100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 810,
          "amount_aed": 3240,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9755
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "4500 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 4500 x 100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1215,
          "amount_aed": 4860,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9757
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,215.00",
            "TOWER 2 [P]": "1,215.00",
            "TOWER 3 [Q]": "1,215.00",
            "TOWER 4 [R]": "1,215.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/174-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "5000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 5000 x 50mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 8100,
          "amount_state": "number",
          "printed_page": "2/Q/56",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9759
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "1,350.00",
            "TOWER 2 [P]": "1,350.00",
            "TOWER 3 [Q]": "1,350.00",
            "TOWER 4 [R]": "1,350.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/175",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 678630,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/175-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "5000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 5000 x 100mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1400,
          "amount_aed": 15400,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,200.00",
            "TOWER 1 [O]": "2,800.00",
            "TOWER 2 [P]": "2,800.00",
            "TOWER 3 [Q]": "2,800.00",
            "TOWER 4 [R]": "2,800.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "6000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 6000 x 100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1680,
          "amount_aed": 6720,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "7000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 7000 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1960,
          "amount_aed": 7840,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,960.00",
            "TOWER 2 [P]": "1,960.00",
            "TOWER 3 [Q]": "1,960.00",
            "TOWER 4 [R]": "1,960.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Return grille"
          ],
          "own_description": "7500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Return grille — 7500 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 8400,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,100.00",
            "TOWER 2 [P]": "2,100.00",
            "TOWER 3 [Q]": "2,100.00",
            "TOWER 4 [R]": "2,100.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply linear bar grille (SLBG)"
          ],
          "own_description": "1000 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply linear bar grille (SLBG) — 1000 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply linear bar grille (SLBG)"
          ],
          "own_description": "1100 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply linear bar grille (SLBG) — 1100 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply linear bar grille (SLBG)"
          ],
          "own_description": "1500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply linear bar grille (SLBG) — 1500 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply linear bar grille (SLBG)"
          ],
          "own_description": "3000 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply linear bar grille (SLBG) — 3000 x 100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 810,
          "amount_aed": 810,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "810.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Supply linear bar grille (SLBG)"
          ],
          "own_description": "5000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Supply linear bar grille (SLBG) — 5000 x 50mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Return air bellmouth with wire mesh and insect screen"
          ],
          "own_description": "500 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Return air bellmouth with wire mesh and insect screen — 500 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 650,
          "amount_aed": 650,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Return air bellmouth with wire mesh and insect screen"
          ],
          "own_description": "800 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Return air bellmouth with wire mesh and insect screen — 800 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 1700,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Return air bellmouth with wire mesh and insect screen"
          ],
          "own_description": "1000 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Return air bellmouth with wire mesh and insect screen — 1000 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 1100,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/175-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 1000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 1000mm long",
          "quantity": 3097,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 495520,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "116",
            "Tower 1 [E]": "689",
            "Tower 2 [F]": "885",
            "Tower 3 [G]": "684",
            "Tower 4 [H]": "723",
            "TOTAL QTY [I]": "3,097",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,560.00",
            "TOWER 1 [O]": "110,240.00",
            "TOWER 2 [P]": "141,600.00",
            "TOWER 3 [Q]": "109,440.00",
            "TOWER 4 [R]": "115,680.00",
            "[S]": "TRUE",
            "[T]": "5440"
          }
        },
        {
          "id": "2 - Main/175-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 1500mm long",
          "quantity": 420,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 100800,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "133",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "154",
            "Tower 4 [H]": "97",
            "TOTAL QTY [I]": "420",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,680.00",
            "TOWER 1 [O]": "31,920.00",
            "TOWER 2 [P]": "960.00",
            "TOWER 3 [Q]": "36,960.00",
            "TOWER 4 [R]": "23,280.00",
            "[S]": "TRUE",
            "[T]": "-8640"
          }
        },
        {
          "id": "2 - Main/175-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 2000mm long",
          "quantity": 107,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 34240,
          "amount_state": "number",
          "printed_page": "2/Q/57",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "28,160.00",
            "TOWER 2 [P]": "1,280.00",
            "TOWER 3 [Q]": "1,280.00",
            "TOWER 4 [R]": "1,280.00",
            "[S]": "TRUE",
            "[T]": "-26880"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/176",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 761850,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/176-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 2500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 2500mm long",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "800.00",
            "TOWER 2 [P]": "800.00",
            "TOWER 3 [Q]": "800.00",
            "TOWER 4 [R]": "800.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 3000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 3000mm long",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,440.00",
            "TOWER 1 [O]": "1,440.00",
            "TOWER 2 [P]": "1,440.00",
            "TOWER 3 [Q]": "1,440.00",
            "TOWER 4 [R]": "1,440.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 4000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 4000mm long",
          "quantity": 188,
          "unit": "Nr.",
          "rate_aed": 640,
          "amount_aed": 120320,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "95",
            "Tower 2 [F]": "57",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "188",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,360.00",
            "TOWER 1 [O]": "60,800.00",
            "TOWER 2 [P]": "36,480.00",
            "TOWER 3 [Q]": "4,480.00",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/176-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 5000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 1-slot, 20 x 5000mm long",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 12800,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 1000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 1000mm long",
          "quantity": 181,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 32580,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "78",
            "TOTAL QTY [I]": "181",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "18,540.00",
            "TOWER 4 [R]": "14,040.00",
            "[S]": "TRUE",
            "[T]": "14040"
          }
        },
        {
          "id": "2 - Main/176-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 1500mm long",
          "quantity": 55,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 14850,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9841
          },
          "extra_columns": {
            "Basement [C]": "24",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "15",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "6,480.00",
            "GF & PODIUM [N]": "4,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 2000mm long",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 12240,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9843
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "5,760.00",
            "GF & PODIUM [N]": "5,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 3000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 3000mm long",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 21060,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,940.00",
            "TOWER 3 [Q]": "13,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 4000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 4000mm long",
          "quantity": 139,
          "unit": "Nr.",
          "rate_aed": 720,
          "amount_aed": 100080,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "77",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "139",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,680.00",
            "TOWER 3 [Q]": "55,440.00",
            "TOWER 4 [R]": "12,960.00",
            "[S]": "TRUE",
            "[T]": "12960"
          }
        },
        {
          "id": "2 - Main/176-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 6000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 6000mm long",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1080,
          "amount_aed": 4320,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 7500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 2-slot, 20 x 7500mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "3-slot, 20 x 1000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 3-slot, 20 x 1000mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "3-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 3-slot, 20 x 1500mm long",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear slot diffuser"
          ],
          "own_description": "3-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear slot diffuser — 3-slot, 20 x 2000mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 1000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 1000mm long",
          "quantity": 1615,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 258400,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "66",
            "Tower 1 [E]": "325",
            "Tower 2 [F]": "461",
            "Tower 3 [G]": "392",
            "Tower 4 [H]": "371",
            "TOTAL QTY [I]": "1,615",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,560.00",
            "TOWER 1 [O]": "52,000.00",
            "TOWER 2 [P]": "73,760.00",
            "TOWER 3 [Q]": "62,720.00",
            "TOWER 4 [R]": "59,360.00",
            "[S]": "TRUE",
            "[T]": "7360"
          }
        },
        {
          "id": "2 - Main/176-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 1500mm long",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 6960,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,640.00",
            "TOWER 1 [O]": "240.00",
            "TOWER 2 [P]": "3,360.00",
            "TOWER 3 [Q]": "240.00",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE",
            "[T]": "240"
          }
        },
        {
          "id": "2 - Main/176-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 2000mm long",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "640.00",
            "TOWER 1 [O]": "640.00",
            "TOWER 2 [P]": "640.00",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-640"
          }
        },
        {
          "id": "2 - Main/176-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 2500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 2500mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-400"
          }
        },
        {
          "id": "2 - Main/176-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 3000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 3000mm long",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 18720,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/176-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "1-slot, 20 x 4000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 1-slot, 20 x 4000mm long",
          "quantity": 170,
          "unit": "Nr.",
          "rate_aed": 640,
          "amount_aed": 108800,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "52",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,360.00",
            "TOWER 1 [O]": "58,880.00",
            "TOWER 2 [P]": "33,280.00",
            "TOWER 3 [Q]": "1,280.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-58880"
          }
        },
        {
          "id": "2 - Main/176-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 1000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 1000mm long",
          "quantity": 180,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 32400,
          "amount_state": "number",
          "printed_page": "2/Q/58",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9873
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "101",
            "Tower 4 [H]": "79",
            "TOTAL QTY [I]": "180",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "18,180.00",
            "TOWER 4 [R]": "14,220.00",
            "[S]": "TRUE",
            "[T]": "14220"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/177",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 704990,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/177-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 1500mm long",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2430,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9889
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,430.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 2000mm long",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 9360,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9891
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "5,760.00",
            "GF & PODIUM [N]": "2,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "360"
          }
        },
        {
          "id": "2 - Main/177-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 3000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 3000mm long",
          "quantity": 51,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 27540,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,500.00",
            "TOWER 4 [R]": "12,960.00",
            "[S]": "TRUE",
            "[T]": "12960"
          }
        },
        {
          "id": "2 - Main/177-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 4000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 4000mm long",
          "quantity": 131,
          "unit": "Nr.",
          "rate_aed": 720,
          "amount_aed": 94320,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9895
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "40",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "78",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,800.00",
            "TOWER 3 [Q]": "9,360.00",
            "TOWER 4 [R]": "56,160.00",
            "[S]": "TRUE",
            "[T]": "56160"
          }
        },
        {
          "id": "2 - Main/177-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "2-slot, 20 x 6000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 2-slot, 20 x 6000mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1080,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "3-slot, 20 x 1500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 3-slot, 20 x 1500mm long",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9899
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear slot diffuser"
          ],
          "own_description": "3-slot, 20 x 2000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear slot diffuser — 3-slot, 20 x 2000mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9901
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 500 x 150mm",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 38800,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "9,200.00",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "9,800.00",
            "TOWER 4 [R]": "9,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "600 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 600 x 150mm",
          "quantity": 368,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 92000,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "84",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "368",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "22,000.00",
            "TOWER 2 [P]": "21,000.00",
            "TOWER 3 [Q]": "25,000.00",
            "TOWER 4 [R]": "22,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 700 x 150mm",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 50440,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,560.00",
            "TOWER 1 [O]": "11,960.00",
            "TOWER 2 [P]": "11,700.00",
            "TOWER 3 [Q]": "13,260.00",
            "TOWER 4 [R]": "11,960.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 750 x 150mm",
          "quantity": 51,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 13770,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,350.00",
            "TOWER 1 [O]": "12,420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12420"
          }
        },
        {
          "id": "2 - Main/177-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 800 x 150mm",
          "quantity": 328,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 91840,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9913
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "86",
            "Tower 3 [G]": "96",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,920.00",
            "TOWER 1 [O]": "12,320.00",
            "TOWER 2 [P]": "24,080.00",
            "TOWER 3 [Q]": "26,880.00",
            "TOWER 4 [R]": "24,640.00",
            "[S]": "TRUE",
            "[T]": "12320"
          }
        },
        {
          "id": "2 - Main/177-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1000 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1000 x 150mm",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 56260,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "13,340.00",
            "TOWER 2 [P]": "13,050.00",
            "TOWER 3 [Q]": "14,210.00",
            "TOWER 4 [R]": "13,340.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1050 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1050 x 150mm",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 107590,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,900.00",
            "TOWER 1 [O]": "25,520.00",
            "TOWER 2 [P]": "24,650.00",
            "TOWER 3 [Q]": "29,000.00",
            "TOWER 4 [R]": "25,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1200 x 150mm",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "660.00",
            "TOWER 1 [O]": "15,840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15840"
          }
        },
        {
          "id": "2 - Main/177-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1250 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "690.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1400 x 150mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 1950,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9923
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Supply linear bar grille"
          ],
          "own_description": "1500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Supply linear bar grille — 1500 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 435,
          "amount_aed": 1740,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,740.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/177-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 500 x 50mm",
          "quantity": 384,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "200",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "184",
            "TOTAL QTY [I]": "384",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "30,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,600.00",
            "[S]": "TRUE",
            "[T]": "27600"
          }
        },
        {
          "id": "2 - Main/177-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "500 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 500 x 100mm",
          "quantity": 196,
          "unit": "Nr.",
          "rate_aed": 190,
          "amount_aed": 37240,
          "amount_state": "number",
          "printed_page": "2/Q/59",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9931
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "196",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "196",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "37,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/178",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 535065,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/178-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "500 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 500 x 150mm",
          "quantity": 196,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 39200,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9947
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "196",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "9,200.00",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "10,200.00",
            "TOWER 4 [R]": "9,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "700 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 700 x 150mm",
          "quantity": 754,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 196040,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9949
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "180",
            "Tower 2 [F]": "174",
            "Tower 3 [G]": "200",
            "Tower 4 [H]": "180",
            "TOTAL QTY [I]": "754",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,200.00",
            "TOWER 1 [O]": "46,800.00",
            "TOWER 2 [P]": "45,240.00",
            "TOWER 3 [Q]": "52,000.00",
            "TOWER 4 [R]": "46,800.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "750 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 750 x 150mm",
          "quantity": 51,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 13770,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,350.00",
            "TOWER 1 [O]": "12,420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12420"
          }
        },
        {
          "id": "2 - Main/178-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "800 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 800 x 150mm",
          "quantity": 146,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 40880,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9953
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "48",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "146",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,040.00",
            "TOWER 3 [Q]": "13,440.00",
            "TOWER 4 [R]": "12,320.00",
            "[S]": "TRUE",
            "[T]": "12320"
          }
        },
        {
          "id": "2 - Main/178-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1000 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1000 x 50mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 1160,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9955
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "580.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "580.00",
            "[S]": "TRUE",
            "[T]": "580"
          }
        },
        {
          "id": "2 - Main/178-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1000 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1000 x 150mm",
          "quantity": 196,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 56840,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9957
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "196",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "13,340.00",
            "TOWER 2 [P]": "13,050.00",
            "TOWER 3 [Q]": "14,790.00",
            "TOWER 4 [R]": "13,340.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1050 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1050 x 150mm",
          "quantity": 371,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 107590,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9959
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "88",
            "TOTAL QTY [I]": "371",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,900.00",
            "TOWER 1 [O]": "25,520.00",
            "TOWER 2 [P]": "24,650.00",
            "TOWER 3 [Q]": "29,000.00",
            "TOWER 4 [R]": "25,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1100 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1100 x 50mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9961
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "300.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1200 x 150mm",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "660.00",
            "TOWER 1 [O]": "15,840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15840"
          }
        },
        {
          "id": "2 - Main/178-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1250 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1250 x 150mm",
          "quantity": 147,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 50715,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "147",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,725.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "15,525.00",
            "TOWER 3 [Q]": "17,595.00",
            "TOWER 4 [R]": "15,870.00",
            "[S]": "TRUE",
            "[T]": "15870"
          }
        },
        {
          "id": "2 - Main/178-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1400 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1400 x 150mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 1950,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary",
            "Return linear bar grille"
          ],
          "own_description": "1500 x 50mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum linear slot diffuser; including plaster frame T-bar slot, fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories and all ancillary works as necessary — Return linear bar grille — 1500 x 50mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 435,
          "amount_aed": 870,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9969
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "870.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B02-01; supply air flow rate of 386 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B02-01; supply air flow rate of 386 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9975
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/178-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B02-02; supply air flow rate of 97 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B02-02; supply air flow rate of 97 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/60",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9977
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/179",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 86920,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/179-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B02-03; supply air flow rate of 438 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B02-03; supply air flow rate of 438 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9997
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B02-04; supply air flow rate of 504 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B02-04; supply air flow rate of 504 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 9999
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B01-01; supply air flow rate of 509 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B01-01; supply air flow rate of 509 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10001
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B01-02; supply air flow rate of 124 l/s and total capacity 1.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B01-02; supply air flow rate of 124 l/s and total capacity 1.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10003
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-B01-03; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-B01-03; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10005
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-01A; supply air flow rate of 350 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-01A; supply air flow rate of 350 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-01B; supply air flow rate of 350 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-01B; supply air flow rate of 350 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-01C; supply air flow rate of 699 l/s and total capacity 9.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-01C; supply air flow rate of 699 l/s and total capacity 9.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-01D; supply air flow rate of 699 l/s and total capacity 9.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-01D; supply air flow rate of 699 l/s and total capacity 9.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-02; supply air flow rate of 219 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-02; supply air flow rate of 219 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-03; supply air flow rate of 63 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-03; supply air flow rate of 63 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-04A; supply air flow rate of 666 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-04A; supply air flow rate of 666 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-04B; supply air flow rate of 666 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-04B; supply air flow rate of 666 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/179-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-05; supply air flow rate of 201 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-05; supply air flow rate of 201 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/61",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/180",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 102220,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/180-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-06; supply air flow rate of 444 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-06; supply air flow rate of 444 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10043
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-07; supply air flow rate of 555 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-07; supply air flow rate of 555 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10045
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-08; supply air flow rate of 175 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-08; supply air flow rate of 175 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10047
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-09; supply air flow rate of 569 l/s and total capacity 7.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-09; supply air flow rate of 569 l/s and total capacity 7.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10049
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-10; supply air flow rate of 376 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-10; supply air flow rate of 376 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-11; supply air flow rate of 584 l/s and total capacity 8.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-11; supply air flow rate of 584 l/s and total capacity 8.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-12A; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-12A; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14670,
          "amount_aed": 14670,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-12B; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-12B; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14670,
          "amount_aed": 14670,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-GF-12C; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-GF-12C; supply air flow rate of 1170 l/s and total capacity 16.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14670,
          "amount_aed": 14670,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-GF-13; supply air flow rate of 201 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-GF-13; supply air flow rate of 201 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/180-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-02; supply air flow rate of 380 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-02; supply air flow rate of 380 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/62",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/181",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 66940,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/181-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-03; supply air flow rate of 606 l/s and total capacity 7.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-03; supply air flow rate of 606 l/s and total capacity 7.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-04-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-04-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10091
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-04-02; supply air flow rate of 169 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-04-02; supply air flow rate of 169 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P01-04-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P01-04-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-01-01; supply air flow rate of 249 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-01-01; supply air flow rate of 249 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-01-02; supply air flow rate of 211 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-01-02; supply air flow rate of 211 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-01-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-01-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-02; supply air flow rate of 432 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-02; supply air flow rate of 432 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-03-01; supply air flow rate of 424 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-03-01; supply air flow rate of 424 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-03-02; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-03-02; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-03-03; supply air flow rate of 258 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-03-03; supply air flow rate of 258 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-03-04; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-03-04; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-04-01; supply air flow rate of 406 l/s and total capacity 7.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-04-01; supply air flow rate of 406 l/s and total capacity 7.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/181-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-05-01; supply air flow rate of 365 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-05-01; supply air flow rate of 365 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/63",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/182",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 76830,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/182-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-05-02; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-05-02; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-05-03; supply air flow rate of 182 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-05-03; supply air flow rate of 182 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-06A; supply air flow rate of 436 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-06A; supply air flow rate of 436 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-06B; supply air flow rate of 290 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-06B; supply air flow rate of 290 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-06C; supply air flow rate of 289 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-06C; supply air flow rate of 289 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-STAIR 1; supply air flow rate of 837 l/s and total capacity 12.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-STAIR 1; supply air flow rate of 837 l/s and total capacity 12.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13860,
          "amount_aed": 13860,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10145
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P02-STAIR 2; supply air flow rate of 791 l/s and total capacity 12.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P02-STAIR 2; supply air flow rate of 791 l/s and total capacity 12.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13860,
          "amount_aed": 13860,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-01-01; supply air flow rate of 239 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-01-01; supply air flow rate of 239 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-01-02; supply air flow rate of 191 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-01-02; supply air flow rate of 191 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10151
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-02-01; supply air flow rate of 397 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-02-01; supply air flow rate of 397 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-03-01; supply air flow rate of 401 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-03-01; supply air flow rate of 401 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-03-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-03-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/182-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-03-03; supply air flow rate of 258 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-03-03; supply air flow rate of 258 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/64",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/183",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 72090,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/183-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-03-04; supply air flow rate of 158 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-03-04; supply air flow rate of 158 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-04-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-04-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-04-02; supply air flow rate of 234 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-04-02; supply air flow rate of 234 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-04-03; supply air flow rate of 362 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-04-03; supply air flow rate of 362 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-04-04; supply air flow rate of 137 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-04-04; supply air flow rate of 137 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-05-01; supply air flow rate of 364 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-05-01; supply air flow rate of 364 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-06-01; supply air flow rate of 336 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-06-01; supply air flow rate of 336 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-06-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-06-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-06-03; supply air flow rate of 169 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-06-03; supply air flow rate of 169 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-07-01; supply air flow rate of 405 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-07-01; supply air flow rate of 405 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-07-02A; supply air flow rate of 462 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-07-02A; supply air flow rate of 462 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-07-02B; supply air flow rate of 462 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-07-02B; supply air flow rate of 462 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-07-02C; supply air flow rate of 471 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-07-02C; supply air flow rate of 471 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/183-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-07-03; supply air flow rate of 399 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-07-03; supply air flow rate of 399 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/65",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/184",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 672170,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/184-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-08A; supply air flow rate of 356 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-08A; supply air flow rate of 356 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10227
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-08B; supply air flow rate of 255 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-08B; supply air flow rate of 255 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10229
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-08C; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-08C; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10231
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-09-01A; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-09-01A; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10233
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-09-01B; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-09-01B; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-09-01C; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-09-01C; supply air flow rate of 685 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10237
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-09-01D; supply air flow rate of 436 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-09-01D; supply air flow rate of 436 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-P03-09-02; supply air flow rate of 622 l/s and total capacity 12.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-P03-09-02; supply air flow rate of 622 l/s and total capacity 12.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13860,
          "amount_aed": 13860,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/184-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "84,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-84480"
          }
        },
        {
          "id": "2 - Main/184-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/184-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/184-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-02-01; supply air flow rate of 386 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-02-01; supply air flow rate of 386 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/184-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-03-01; supply air flow rate of 395 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-03-01; supply air flow rate of 395 l/s and total capacity 5.6kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/184-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-03-02; supply air flow rate of 153 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-03-02; supply air flow rate of 153 l/s and total capacity 2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/66",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/185",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1440480,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/185-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-03-03; supply air flow rate of 248 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-03-03; supply air flow rate of 248 l/s and total capacity 3.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "84,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-84480"
          }
        },
        {
          "id": "2 - Main/185-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-03-04; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-03-04; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-04-01; supply air flow rate of 373 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-04-01; supply air flow rate of 373 l/s and total capacity 5.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/185-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-04-02; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-04-02; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-04-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-04-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-05; supply air flow rate of 381 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-05; supply air flow rate of 381 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/185-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-06; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-06; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/185-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-07-01; supply air flow rate of 349 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-07-01; supply air flow rate of 349 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "118,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-118800"
          }
        },
        {
          "id": "2 - Main/185-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-07-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-07-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-07-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-07-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-08; supply air flow rate of 353 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-08; supply air flow rate of 353 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "145,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-145200"
          }
        },
        {
          "id": "2 - Main/185-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-09-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-09-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "118,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-118800"
          }
        },
        {
          "id": "2 - Main/185-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        },
        {
          "id": "2 - Main/185-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-09-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-09-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/67",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "76,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-76800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/186",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 361400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/186-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-10A; supply air flow rate of 298 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-10A; supply air flow rate of 298 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "118,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-118800"
          }
        },
        {
          "id": "2 - Main/186-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-10B; supply air flow rate of 250 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-10B; supply air flow rate of 250 l/s and total capacity 3.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "84,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-84480"
          }
        },
        {
          "id": "2 - Main/186-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-10C1; supply air flow rate of 257 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-10C1; supply air flow rate of 257 l/s and total capacity 3.3kW",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 66880,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "66,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-66880"
          }
        },
        {
          "id": "2 - Main/186-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-10C2; supply air flow rate of 749 l/s and total capacity 9.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-10C2; supply air flow rate of 749 l/s and total capacity 9.4kW",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 50050,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "50,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-50050"
          }
        },
        {
          "id": "2 - Main/186-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-01-01; supply air flow rate of 236 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-01-01; supply air flow rate of 236 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/186-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-01-02; supply air flow rate of 186 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-01-02; supply air flow rate of 186 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/186-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-01-03; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-01-03; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/186-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-02-01; supply air flow rate of 388 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-02-01; supply air flow rate of 388 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/186-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-03-01; supply air flow rate of 397 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-03-01; supply air flow rate of 397 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/186-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-03-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-03-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/186-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-03-03; supply air flow rate of 241 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-03-03; supply air flow rate of 241 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/186-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-03-04; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-03-04; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/186-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-04-01; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-04-01; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/186-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-04-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-04-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/68",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/187",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 67150,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/187-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-04-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-04-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10365
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/187-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-05-01; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-05-01; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10367
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/187-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-06-01; supply air flow rate of 390 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-06-01; supply air flow rate of 390 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10369
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/187-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-07-01; supply air flow rate of 352 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-07-01; supply air flow rate of 352 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10371
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/187-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-07-02; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-07-02; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10373
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/187-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-07-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-07-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10375
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/187-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-08-01; supply air flow rate of 357 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-08-01; supply air flow rate of 357 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/187-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-09-01; supply air flow rate of 329 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-09-01; supply air flow rate of 329 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4950"
          }
        },
        {
          "id": "2 - Main/187-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-09-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-09-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/187-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-09-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-09-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/187-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-10A; supply air flow rate of 288 l/s and total capacity 4.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-10A; supply air flow rate of 288 l/s and total capacity 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4950"
          }
        },
        {
          "id": "2 - Main/187-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-10B; supply air flow rate of 230 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-10B; supply air flow rate of 230 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/187-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T01-28F-10C2; supply air flow rate of 751 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T01-28F-10C2; supply air flow rate of 751 l/s and total capacity 9.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,010.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10010"
          }
        },
        {
          "id": "2 - Main/187-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/69",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/188",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 62640,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/188-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/188-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/188-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-02-01; supply air flow rate of 385 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-02-01; supply air flow rate of 385 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/188-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-03-01; supply air flow rate of 524 l/s and total capacity 6.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-03-01; supply air flow rate of 524 l/s and total capacity 6.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/188-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-04-01; supply air flow rate of 327 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-04-01; supply air flow rate of 327 l/s and total capacity 4.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10419
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4950"
          }
        },
        {
          "id": "2 - Main/188-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-04-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-04-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/188-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-04-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-04-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10423
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/188-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-05A; supply air flow rate of 240 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-05A; supply air flow rate of 240 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/188-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-05B; supply air flow rate of 58 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-05B; supply air flow rate of 58 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/188-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-05C; supply air flow rate of 240 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-05C; supply air flow rate of 240 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/188-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-05D; supply air flow rate of 256 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-05D; supply air flow rate of 256 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/188-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 01A; supply air flow rate of 405 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 01A; supply air flow rate of 405 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/188-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 01B; supply air flow rate of 405 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 01B; supply air flow rate of 405 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/188-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02A; supply air flow rate of 424 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02A; supply air flow rate of 424 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/70",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/189",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 63750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/189-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02B; supply air flow rate of 424 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02B; supply air flow rate of 424 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10457
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/189-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03A; supply air flow rate of 415 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03A; supply air flow rate of 415 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10459
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/189-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03B; supply air flow rate of 415 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03B; supply air flow rate of 415 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/189-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-06-01; supply air flow rate of 84 l/s and total capacity 1.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-06-01; supply air flow rate of 84 l/s and total capacity 1.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-06-02; supply air flow rate of 64 l/s and total capacity 0.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-06-02; supply air flow rate of 64 l/s and total capacity 0.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-01-01; supply air flow rate of 239 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-01-01; supply air flow rate of 239 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/189-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-02-01; supply air flow rate of 397 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-02-01; supply air flow rate of 397 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/189-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-03-01; supply air flow rate of 535 l/s and total capacity 7.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-03-01; supply air flow rate of 535 l/s and total capacity 7.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8360"
          }
        },
        {
          "id": "2 - Main/189-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-04-01; supply air flow rate of 337 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-04-01; supply air flow rate of 337 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4950"
          }
        },
        {
          "id": "2 - Main/189-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-04-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-04-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-04-03; supply air flow rate of 169 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-04-03; supply air flow rate of 169 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/189-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-05A; supply air flow rate of 200 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-05A; supply air flow rate of 200 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/71",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/190",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 825630,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/190-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-05B; supply air flow rate of 230 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-05B; supply air flow rate of 230 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/190-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-05C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-05C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10505
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/190-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-30F-STAIR 1; supply air flow rate of 1047 l/s and total capacity 15.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-30F-STAIR 1; supply air flow rate of 1047 l/s and total capacity 15.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14130,
          "amount_aed": 14130,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,130.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-14130"
          }
        },
        {
          "id": "2 - Main/190-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-01-01; supply air flow rate of 235 l/s and total capacity 3.5kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 63360,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10509
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "63,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-63360"
          }
        },
        {
          "id": "2 - Main/190-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-01-02; supply air flow rate of 184 l/s and total capacity 2.3kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10511
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/190-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-01-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10513
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/190-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-02-01; supply air flow rate of 386 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-02-01; supply air flow rate of 386 l/s and total capacity 5.3kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/190-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-03-01; supply air flow rate of 395 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-03-01; supply air flow rate of 395 l/s and total capacity 5.6kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10517
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/190-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-03-02; supply air flow rate of 153 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-03-02; supply air flow rate of 153 l/s and total capacity 2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 63360,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10519
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "63,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-63360"
          }
        },
        {
          "id": "2 - Main/190-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-03-03; supply air flow rate of 248 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-03-03; supply air flow rate of 248 l/s and total capacity 3.3kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 63360,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "63,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-63360"
          }
        },
        {
          "id": "2 - Main/190-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-03-04; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-03-04; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10523
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/190-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-04-01; supply air flow rate of 373 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-04-01; supply air flow rate of 373 l/s and total capacity 5.2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/190-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-04-02; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-04-02; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10527
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/190-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-04-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-04-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/72",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10529
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/191",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 980600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/191-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-05-01; supply air flow rate of 381 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-05-01; supply air flow rate of 381 l/s and total capacity 5.3kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/191-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-06-01; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-06-01; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10551
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/191-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-07-01; supply air flow rate of 349 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-07-01; supply air flow rate of 349 l/s and total capacity 4.9kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 89100,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10553
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "89,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-89100"
          }
        },
        {
          "id": "2 - Main/191-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-07-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-07-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/191-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-07-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-07-03; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/191-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-08-01; supply air flow rate of 353 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-08-01; supply air flow rate of 353 l/s and total capacity 5kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 108900,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108900"
          }
        },
        {
          "id": "2 - Main/191-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-09-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-09-01; supply air flow rate of 326 l/s and total capacity 4.6kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 89100,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "89,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-89100"
          }
        },
        {
          "id": "2 - Main/191-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/191-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-09-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-09-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 57600,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "57,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-57600"
          }
        },
        {
          "id": "2 - Main/191-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-10A; supply air flow rate of 281 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-10A; supply air flow rate of 281 l/s and total capacity 4.1kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 89100,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "89,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-89100"
          }
        },
        {
          "id": "2 - Main/191-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-10B; supply air flow rate of 226 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-10B; supply air flow rate of 226 l/s and total capacity 3.1kW",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 63360,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "63,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-63360"
          }
        },
        {
          "id": "2 - Main/191-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-10C1; supply air flow rate of 257 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-10C1; supply air flow rate of 257 l/s and total capacity 3.3kW",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 49280,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "49,280.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-49280"
          }
        },
        {
          "id": "2 - Main/191-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-10C2; supply air flow rate of 749 l/s and total capacity 9.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-10C2; supply air flow rate of 749 l/s and total capacity 9.4kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "40,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-40040"
          }
        },
        {
          "id": "2 - Main/191-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-01-01; supply air flow rate of 251 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-01-01; supply air flow rate of 251 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/73",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/192",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 65740,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/192-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-01-02; supply air flow rate of 215 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-01-02; supply air flow rate of 215 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-01-03; supply air flow rate of 182 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-01-03; supply air flow rate of 182 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10597
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-02-01; supply air flow rate of 449 l/s and total capacity 6.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-02-01; supply air flow rate of 449 l/s and total capacity 6.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/192-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-03-01; supply air flow rate of 432 l/s and total capacity 6.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-03-01; supply air flow rate of 432 l/s and total capacity 6.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/192-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-03-02; supply air flow rate of 168 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-03-02; supply air flow rate of 168 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-03-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-03-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/192-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-03-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-03-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-04-01; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-04-01; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/192-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-04-03; supply air flow rate of 198 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-04-03; supply air flow rate of 198 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-05-01; supply air flow rate of 435 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-05-01; supply air flow rate of 435 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/192-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-06-01; supply air flow rate of 444 l/s and total capacity 6.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-06-01; supply air flow rate of 444 l/s and total capacity 6.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/192-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-07-01; supply air flow rate of 421 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-07-01; supply air flow rate of 421 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/192-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-07-02; supply air flow rate of 202 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-07-02; supply air flow rate of 202 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/192-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-07-03; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-07-03; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/74",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/193",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 250900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/193-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49F-08-01; supply air flow rate of 434 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49F-08-01; supply air flow rate of 434 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,930.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6930"
          }
        },
        {
          "id": "2 - Main/193-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-09-01; supply air flow rate of 398 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-09-01; supply air flow rate of 398 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10643
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/193-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-09-02; supply air flow rate of 196 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-09-02; supply air flow rate of 196 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10645
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/193-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-09-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-09-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10647
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/193-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-10A; supply air flow rate of 391 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-10A; supply air flow rate of 391 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10649
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/193-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-10B; supply air flow rate of 290 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-10B; supply air flow rate of 290 l/s and total capacity 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10651
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4950"
          }
        },
        {
          "id": "2 - Main/193-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-T02-49-10C; supply air flow rate of 294 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-T02-49-10C; supply air flow rate of 294 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10653
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/193-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-01A; supply air flow rate of 747 l/s and total capacity 9.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-01A; supply air flow rate of 747 l/s and total capacity 9.6kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10655
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,010.00",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "10,010.00",
            "TOWER 4 [R]": "10,010.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-01B; supply air flow rate of 747 l/s and total capacity 9.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-01B; supply air flow rate of 747 l/s and total capacity 9.6kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10657
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,010.00",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "10,010.00",
            "TOWER 4 [R]": "10,010.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-02; supply air flow rate of 689 l/s and total capacity 9.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-02; supply air flow rate of 689 l/s and total capacity 9.2kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10659
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,010.00",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "10,010.00",
            "TOWER 4 [R]": "10,010.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-03A; supply air flow rate of 606 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-03A; supply air flow rate of 606 l/s and total capacity 8.3kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 35640,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10661
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,910.00",
            "TOWER 2 [P]": "8,910.00",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "8,910.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-03B; supply air flow rate of 606 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-03B; supply air flow rate of 606 l/s and total capacity 8.3kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 35640,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,910.00",
            "TOWER 2 [P]": "8,910.00",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "8,910.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-04; supply air flow rate of 158 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-04; supply air flow rate of 158 l/s and total capacity 2.3kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 12800,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10665
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/193-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-05; supply air flow rate of 91 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-05; supply air flow rate of 91 l/s and total capacity 1.2kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 12800,
          "amount_state": "number",
          "printed_page": "2/Q/75",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/194",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 200200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/194-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 12800,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-07; supply air flow rate of 228 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-07; supply air flow rate of 228 l/s and total capacity 3kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 14080,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-08; supply air flow rate of 232 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-08; supply air flow rate of 232 l/s and total capacity 3.1kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 14080,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-09; supply air flow rate of 617 l/s and total capacity 7.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-09; supply air flow rate of 617 l/s and total capacity 7.9kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 33440,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,360.00",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "8,360.00",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-10; supply air flow rate of 416 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-10; supply air flow rate of 416 l/s and total capacity 5.3kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 24200,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-11; supply air flow rate of 281 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-11; supply air flow rate of 281 l/s and total capacity 3.7kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 14080,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-12A; supply air flow rate of 413 l/s and total capacity 5.65kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-12A; supply air flow rate of 413 l/s and total capacity 5.65kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 24200,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-01-12B; supply air flow rate of 413 l/s and total capacity 5.65kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-01-12B; supply air flow rate of 413 l/s and total capacity 5.65kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 24200,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/194-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-02A; supply air flow rate of 388 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-02A; supply air flow rate of 388 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10703
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/194-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-02B; supply air flow rate of 295 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-02B; supply air flow rate of 295 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/194-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-50F-02C; supply air flow rate of 149 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-50F-02C; supply air flow rate of 149 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10707
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/194-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-LRF-01; supply air flow rate of 106 l/s and total capacity 1.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-LRF-01; supply air flow rate of 106 l/s and total capacity 1.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10709
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/194-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-LRF-02; supply air flow rate of 421 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-LRF-02; supply air flow rate of 421 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10711
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,050.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6050"
          }
        },
        {
          "id": "2 - Main/194-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-LRF-STAIR 1; supply air flow rate of 1340 l/s and total capacity 19.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-LRF-STAIR 1; supply air flow rate of 1340 l/s and total capacity 19.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17100,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/Q/76",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10713
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17100"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/195",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 86540,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/195-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-LRF-STAIR 2; supply air flow rate of 944 l/s and total capacity 14.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-LRF-STAIR 2; supply air flow rate of 944 l/s and total capacity 14.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-14000"
          }
        },
        {
          "id": "2 - Main/195-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-RF-01; supply air flow rate of 806 l/s and total capacity 11.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-RF-01; supply air flow rate of 806 l/s and total capacity 11.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12319.999999999998,
          "amount_aed": 12319.999999999998,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12320"
          }
        },
        {
          "id": "2 - Main/195-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "Tl-RF-02; supply air flow rate of 215 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — Tl-RF-02; supply air flow rate of 215 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/195-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B02-01; supply air flow rate of 319 l/s and total capacity 4.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B02-01; supply air flow rate of 319 l/s and total capacity 4.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10739
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "4,950.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B02-02; supply air flow rate of 96 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B02-02; supply air flow rate of 96 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10741
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B02-03; supply air flow rate of 444 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B02-03; supply air flow rate of 444 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10743
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B02-04; supply air flow rate of 180 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B02-04; supply air flow rate of 180 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10745
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B02-05; supply air flow rate of 77 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B02-05; supply air flow rate of 77 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10747
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-01; supply air flow rate of 416 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-01; supply air flow rate of 416 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10749
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-02; supply air flow rate of 124 l/s and total capacity 1.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-02; supply air flow rate of 124 l/s and total capacity 1.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10751
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-03; supply air flow rate of 518 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-03; supply air flow rate of 518 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10753
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-04A; supply air flow rate of 521 l/s and total capacity 7.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-04A; supply air flow rate of 521 l/s and total capacity 7.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10755
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-04B; supply air flow rate of 521 l/s and total capacity 7.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-04B; supply air flow rate of 521 l/s and total capacity 7.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10757
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/195-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-05; supply air flow rate of 227 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-05; supply air flow rate of 227 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/77",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10759
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/196",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 154890,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/196-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-B01-06; supply air flow rate of 164 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-B01-06; supply air flow rate of 164 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10779
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-01A; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-01A; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-01B; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-01B; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-01C; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-01C; supply air flow rate of 754 l/s and total capacity 10.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-02A; supply air flow rate of 702 l/s and total capacity 9.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-02A; supply air flow rate of 702 l/s and total capacity 9.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-02B; supply air flow rate of 702 l/s and total capacity 9.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-02B; supply air flow rate of 702 l/s and total capacity 9.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-03; supply air flow rate of 655 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-03; supply air flow rate of 655 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-04A; supply air flow rate of 819 l/s and total capacity 9.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-04A; supply air flow rate of 819 l/s and total capacity 9.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-04B; supply air flow rate of 819 l/s and total capacity 9.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-04B; supply air flow rate of 819 l/s and total capacity 9.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-05A; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-05A; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 20790,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,790.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-05B; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-05B; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 20790,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,790.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-05C; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-05C; supply air flow rate of 385 l/s and total capacity 6.5kW",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 20790,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,790.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-06; supply air flow rate of 65 l/s and total capacity 0.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-06; supply air flow rate of 65 l/s and total capacity 0.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/196-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-07A; supply air flow rate of 415 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-07A; supply air flow rate of 415 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/78",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/197",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 63200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/197-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-07B; supply air flow rate of 415 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-07B; supply air flow rate of 415 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-08; supply air flow rate of 79 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-08; supply air flow rate of 79 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-08A; supply air flow rate of 132 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-08A; supply air flow rate of 132 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10829
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-09; supply air flow rate of 219 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-09; supply air flow rate of 219 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-10A; supply air flow rate of 157 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-10A; supply air flow rate of 157 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-10B; supply air flow rate of 421 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-10B; supply air flow rate of 421 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-11; supply air flow rate of 138 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-11; supply air flow rate of 138 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-12; supply air flow rate of 135 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-12; supply air flow rate of 135 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-01; supply air flow rate of 575 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-01; supply air flow rate of 575 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-02; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-02; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-03-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-03-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-03-02; supply air flow rate of 143 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-03-02; supply air flow rate of 143 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-03-03; supply air flow rate of 142 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-03-03; supply air flow rate of 142 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/197-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-04A; supply air flow rate of 434 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-04A; supply air flow rate of 434 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/79",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/198",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 74390,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/198-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-04B; supply air flow rate of 434 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-04B; supply air flow rate of 434 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-05A; supply air flow rate of 278 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-05A; supply air flow rate of 278 l/s and total capacity 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10873
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-05B; supply air flow rate of 360 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-05B; supply air flow rate of 360 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10875
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-05C; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-05C; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10877
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P01-05D; supply air flow rate of 53 l/s and total capacity 0.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P01-05D; supply air flow rate of 53 l/s and total capacity 0.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-01; supply air flow rate of 583 l/s and total capacity 7.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-01; supply air flow rate of 583 l/s and total capacity 7.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10881
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-02; supply air flow rate of 450 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-02; supply air flow rate of 450 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-03-01; supply air flow rate of 420 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-03-01; supply air flow rate of 420 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10885
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-03-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-03-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-03-03; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-03-03; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10889
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-04; supply air flow rate of 378 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-04; supply air flow rate of 378 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10891
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-05; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-05; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-07A; supply air flow rate of 311 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-07A; supply air flow rate of 311 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10895
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/198-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-07B; supply air flow rate of 433 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-07B; supply air flow rate of 433 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/80",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/199",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 86140,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/199-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-07C; supply air flow rate of 289 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-07C; supply air flow rate of 289 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-08; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-08; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-STAIR 01; supply air flow rate of 1284 l/s and total capacity 19.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-STAIR 01; supply air flow rate of 1284 l/s and total capacity 19.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17100,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P02-STAIR 02; supply air flow rate of 922 l/s and total capacity 14.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P02-STAIR 02; supply air flow rate of 922 l/s and total capacity 14.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10923
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-01-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-01-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-01-02; supply air flow rate of 179 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-01-02; supply air flow rate of 179 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-01-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-01-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-02; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-02; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10931
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-03-01; supply air flow rate of 391 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-03-01; supply air flow rate of 391 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10933
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-03-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-03-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10935
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-03-03; supply air flow rate of 153 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-03-03; supply air flow rate of 153 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-04; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-04; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10939
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-05; supply air flow rate of 355 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-05; supply air flow rate of 355 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/199-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-06-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-06-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/81",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10943
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/200",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 89970,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/200-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-06-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-06-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-07; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-07; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-08A; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-08A; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10969
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-08B; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-08B; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-08C; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-08C; supply air flow rate of 588 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10973
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-09A; supply air flow rate of 157 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-09A; supply air flow rate of 157 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10975
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-09B; supply air flow rate of 143 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-09B; supply air flow rate of 143 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10977
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-10A; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-10A; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10979
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-10B; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-10B; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10981
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-10C; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-10C; supply air flow rate of 593 l/s and total capacity 7.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10983
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-10D; supply air flow rate of 724 l/s and total capacity 9.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-10D; supply air flow rate of 724 l/s and total capacity 9.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10985
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-11A; supply air flow rate of 374 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-11A; supply air flow rate of 374 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10987
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/200-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-11B; supply air flow rate of 233 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-11B; supply air flow rate of 233 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3250,
          "amount_aed": 3250,
          "amount_state": "number",
          "printed_page": "2/Q/82",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 10989
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/201",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1306480,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/201-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-P03-11C; supply air flow rate of 269 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-P03-11C; supply air flow rate of 269 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "84,480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "84,480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-TO 1-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-TO 1-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-04-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-04-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "118,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/201-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/83",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11035
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "118,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/202",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1280720,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/202-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-07-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-07-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "145,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "76,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "118,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "84,480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "84,480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 240240,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "240,240.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/202-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/84",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/203",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 62870,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/203-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-02-03; supply air flow rate of 265 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-02-03; supply air flow rate of 265 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-04-02; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-04-02; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-07-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-07-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/203-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/85",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11127
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/204",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 62870,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/204-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-28-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-28-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11151
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-10C; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-10C; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-02-01; supply air flow rate of 417 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-02-01; supply air flow rate of 417 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/204-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/86",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/205",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 68590,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/205-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-04A; supply air flow rate of 225 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-04A; supply air flow rate of 225 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-04A1; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-04A1; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-04B; supply air flow rate of 219 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-04B; supply air flow rate of 219 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-29F-04C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-29F-04C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MCC-01; supply air flow rate of 75 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MCC-01; supply air flow rate of 75 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MCC-02; supply air flow rate of 59 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MCC-02; supply air flow rate of 59 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 01; supply air flow rate of 714 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 01; supply air flow rate of 714 l/s and total capacity 9.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02A; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02A; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02B; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02B; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03A; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03A; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03B; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03B; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/205-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/87",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/206",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 71830,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/206-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-02-01; supply air flow rate of 418 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-02-01; supply air flow rate of 418 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-02-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-02-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-04A; supply air flow rate of 245 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-04A; supply air flow rate of 245 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11257
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-04B; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-04B; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-04C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-04C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11261
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-STAIR 01; supply air flow rate of 1046 l/s and total capacity 15.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-STAIR 01; supply air flow rate of 1046 l/s and total capacity 15.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14130,
          "amount_aed": 14130,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11263
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,130.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/206-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-30F-STAIR 02; supply air flow rate of 701 l/s and total capacity 11.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-30F-STAIR 02; supply air flow rate of 701 l/s and total capacity 11.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/88",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/207",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 960320,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/207-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 56320,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "56,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-02-03; supply air flow rate of 219 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-02-03; supply air flow rate of 219 l/s and total capacity 2.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11301
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-04-02; supply air flow rate of 144 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-04-02; supply air flow rate of 144 l/s and total capacity 1.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11303
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "79,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "79,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/207-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/89",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/208",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 632170,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/208-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-07-02; supply air flow rate of 144 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-07-02; supply air flow rate of 144 l/s and total capacity 1.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 96800,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "96,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "51,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-10A; supply air flow rate of 277 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-10A; supply air flow rate of 277 l/s and total capacity 4.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "79,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-10B; supply air flow rate of 222 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-10B; supply air flow rate of 222 l/s and total capacity 3.2kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 56320,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "56,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 42240,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "42,240.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T02-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T02-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11349
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "40,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11351
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11353
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11355
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/208-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/90",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11357
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/209",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 62550,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/209-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-02-03; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-02-03; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-04-02; supply air flow rate of 146 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-04-02; supply air flow rate of 146 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-07-02; supply air flow rate of 146 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-07-02; supply air flow rate of 146 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/209-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/91",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/210",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57260,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/210-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11423
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-10A; supply air flow rate of 284 l/s and total capacity 4.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-10A; supply air flow rate of 284 l/s and total capacity 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-10B; supply air flow rate of 226 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-10B; supply air flow rate of 226 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T01-47-10C; supply air flow rate of 263 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T01-47-10C; supply air flow rate of 263 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-01-01; supply air flow rate of 225 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-01-01; supply air flow rate of 225 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-01-02; supply air flow rate of 204 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-01-02; supply air flow rate of 204 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-01-03; supply air flow rate of 184 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-01-03; supply air flow rate of 184 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-02-01; supply air flow rate of 428 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-02-01; supply air flow rate of 428 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-02-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-02-02; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11441
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-02-03; supply air flow rate of 230 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-02-03; supply air flow rate of 230 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11443
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-02-04; supply air flow rate of 187 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-02-04; supply air flow rate of 187 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-03-01; supply air flow rate of 428 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-03-01; supply air flow rate of 428 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11447
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/210-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-04-01; supply air flow rate of 374 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-04-01; supply air flow rate of 374 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/92",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11449
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/211",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 77080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/211-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-04-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-04-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-04-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-04-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-05-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-05-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-06-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-06-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-06-02; supply air flow rate of 181 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-06-02; supply air flow rate of 181 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-06-03; supply air flow rate of 184 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-06-03; supply air flow rate of 184 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-07A; supply air flow rate of 319 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-07A; supply air flow rate of 319 l/s and total capacity 4.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-07B; supply air flow rate of 248 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-07B; supply air flow rate of 248 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-07C; supply air flow rate of 274 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-07C; supply air flow rate of 274 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-48F-MEP; supply air flow rate of 1131 l/s and total capacity 14.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-48F-MEP; supply air flow rate of 1131 l/s and total capacity 14.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-02; supply air flow rate of 679 l/s and total capacity 9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-02; supply air flow rate of 679 l/s and total capacity 9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-03; supply air flow rate of 478 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-03; supply air flow rate of 478 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/211-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-04A; supply air flow rate of 383 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-04A; supply air flow rate of 383 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/93",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/212",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 79470,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/212-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-04B; supply air flow rate of 383 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-04B; supply air flow rate of 383 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-05; supply air flow rate of 95 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-05; supply air flow rate of 95 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11517
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-06; supply air flow rate of 285 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-06; supply air flow rate of 285 l/s and total capacity 3.8kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 14080,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11519
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-07; supply air flow rate of 207 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-07; supply air flow rate of 207 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-08; supply air flow rate of 353 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-08; supply air flow rate of 353 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11523
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-01-09; supply air flow rate of 546 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-01-09; supply air flow rate of 546 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-02-01; supply air flow rate of 231 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-02-01; supply air flow rate of 231 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11527
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-02-02; supply air flow rate of 127 l/s and total capacity 1.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-02-02; supply air flow rate of 127 l/s and total capacity 1.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11529
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-02-03; supply air flow rate of 231 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-02-03; supply air flow rate of 231 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-02-04; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-02-04; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11533
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-01; supply air flow rate of 97 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-01; supply air flow rate of 97 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-02; supply air flow rate of 694 l/s and total capacity 9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-02; supply air flow rate of 694 l/s and total capacity 9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11537
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-03; supply air flow rate of 493 l/s and total capacity 6.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-03; supply air flow rate of 493 l/s and total capacity 6.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11539
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/212-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-04A; supply air flow rate of 380 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-04A; supply air flow rate of 380 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/94",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11541
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/213",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 67580,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/213-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-04B; supply air flow rate of 380 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-04B; supply air flow rate of 380 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-05; supply air flow rate of 89 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-05; supply air flow rate of 89 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-06; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-06; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-07; supply air flow rate of 207 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-07; supply air flow rate of 207 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-08; supply air flow rate of 353 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-08; supply air flow rate of 353 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-03-09; supply air flow rate of 503 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-03-09; supply air flow rate of 503 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-04A; supply air flow rate of 350 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-04A; supply air flow rate of 350 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-04B; supply air flow rate of 266 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-04B; supply air flow rate of 266 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-04C; supply air flow rate of 270 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-04C; supply air flow rate of 270 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-01; supply air flow rate of 100 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-01; supply air flow rate of 100 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-02; supply air flow rate of 471 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-02; supply air flow rate of 471 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-03; supply air flow rate of 485 l/s and total capacity 6.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-03; supply air flow rate of 485 l/s and total capacity 6.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-04; supply air flow rate of 305 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-04; supply air flow rate of 305 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/213-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-04A; supply air flow rate of 305 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-04A; supply air flow rate of 305 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/95",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/214",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 61880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/214-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-05; supply air flow rate of 70 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-05; supply air flow rate of 70 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-06; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-06; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-07; supply air flow rate of 216 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-07; supply air flow rate of 216 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-08; supply air flow rate of 302 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-08; supply air flow rate of 302 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-01-09; supply air flow rate of 558 l/s and total capacity 7.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-01-09; supply air flow rate of 558 l/s and total capacity 7.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-02-01; supply air flow rate of 235 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-02-01; supply air flow rate of 235 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-02-02; supply air flow rate of 129 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-02-02; supply air flow rate of 129 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-02-03; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-02-03; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-02-04; supply air flow rate of 167 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-02-04; supply air flow rate of 167 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-02; supply air flow rate of 477 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-02; supply air flow rate of 477 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11623
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-03; supply air flow rate of 500 l/s and total capacity 6.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-03; supply air flow rate of 500 l/s and total capacity 6.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11625
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-04A; supply air flow rate of 306 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-04A; supply air flow rate of 306 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11627
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/214-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-04B; supply air flow rate of 306 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-04B; supply air flow rate of 306 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/96",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11629
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/215",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 70990,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/215-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-05; supply air flow rate of 83 l/s and total capacity 1.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-05; supply air flow rate of 83 l/s and total capacity 1.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11642
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-06; supply air flow rate of 215 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-06; supply air flow rate of 215 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11644
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-07; supply air flow rate of 216 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-07; supply air flow rate of 216 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11646
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-08; supply air flow rate of 302 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-08; supply air flow rate of 302 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11648
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-03-09; supply air flow rate of 515 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-03-09; supply air flow rate of 515 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11650
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-04A; supply air flow rate of 325 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-04A; supply air flow rate of 325 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11652
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-04B; supply air flow rate of 283 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-04B; supply air flow rate of 283 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11654
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T03-53-04C; supply air flow rate of 278 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T03-53-04C; supply air flow rate of 278 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-01; supply air flow rate of 99 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-02A; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-02A; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11660
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-02B; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-02B; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11662
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-03; supply air flow rate of 479 l/s and total capacity 6.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-03; supply air flow rate of 479 l/s and total capacity 6.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-04A; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-04A; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/215-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-04B; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-04B; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/97",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/216",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 70030,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/216-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-05; supply air flow rate of 74 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-05; supply air flow rate of 74 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-07; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-07; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11685
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-08; supply air flow rate of 272 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-08; supply air flow rate of 272 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-01-09; supply air flow rate of 546 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-01-09; supply air flow rate of 546 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-01; supply air flow rate of 98 l/s and total capacity 1.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-01; supply air flow rate of 98 l/s and total capacity 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-02A; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-02A; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-02B; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-02B; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-03; supply air flow rate of 495 l/s and total capacity 6.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-03; supply air flow rate of 495 l/s and total capacity 6.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-04A; supply air flow rate of 550 l/s and total capacity 7.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-04A; supply air flow rate of 550 l/s and total capacity 7.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-04B; supply air flow rate of 550 l/s and total capacity 7.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-04B; supply air flow rate of 550 l/s and total capacity 7.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-05; supply air flow rate of 74 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-05; supply air flow rate of 74 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11703
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-06; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/216-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-07; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-07; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/98",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11707
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/217",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 79230,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/217-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-08; supply air flow rate of 272 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-08; supply air flow rate of 272 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11720
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-02-09; supply air flow rate of 503 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-02-09; supply air flow rate of 503 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-03A; supply air flow rate of 295 l/s and total capacity 4.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-03A; supply air flow rate of 295 l/s and total capacity 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-03B; supply air flow rate of 264 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-03B; supply air flow rate of 264 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-03C; supply air flow rate of 270 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-03C; supply air flow rate of 270 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11728
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-T04-03C2; supply air flow rate of 761 l/s and total capacity 9.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-T04-03C2; supply air flow rate of 761 l/s and total capacity 9.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11730
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-01; supply air flow rate of 106 l/s and total capacity 1.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-01; supply air flow rate of 106 l/s and total capacity 1.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11732
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-02A; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-02A; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-02B; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-02B; supply air flow rate of 432 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-03; supply air flow rate of 506 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-03; supply air flow rate of 506 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-04A; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-04A; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11740
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-04B; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-04B; supply air flow rate of 565 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-05; supply air flow rate of 85 l/s and total capacity 1.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-05; supply air flow rate of 85 l/s and total capacity 1.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/217-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-06; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-06; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/99",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/218",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 77260,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/218-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-07; supply air flow rate of 212 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-07; supply air flow rate of 212 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11759
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-08; supply air flow rate of 268 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-08; supply air flow rate of 268 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11761
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-01-09; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-01-09; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11763
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-01; supply air flow rate of 110 l/s and total capacity 1.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-01; supply air flow rate of 110 l/s and total capacity 1.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11765
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-02A; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-02A; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11767
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-02B; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-02B; supply air flow rate of 431 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11769
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-03; supply air flow rate of 543 l/s and total capacity 7.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-03; supply air flow rate of 543 l/s and total capacity 7.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11771
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-04A; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-04A; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11773
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-04B; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-04B; supply air flow rate of 590 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-05; supply air flow rate of 92 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-05; supply air flow rate of 92 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-06; supply air flow rate of 211 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-06; supply air flow rate of 211 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-07; supply air flow rate of 227 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-07; supply air flow rate of 227 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-08; supply air flow rate of 273 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-08; supply air flow rate of 273 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/218-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-02-09; supply air flow rate of 578 l/s and total capacity 7.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-02-09; supply air flow rate of 578 l/s and total capacity 7.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/100",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/219",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 86060,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/219-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-03A; supply air flow rate of 478 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-03A; supply air flow rate of 478 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6390,
          "amount_aed": 6390,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11798
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,390.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-03B; supply air flow rate of 321 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-03B; supply air flow rate of 321 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11800
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-57-03C; supply air flow rate of 298 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-57-03C; supply air flow rate of 298 l/s and total capacity 3.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11802
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-01; supply air flow rate of 145 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-01; supply air flow rate of 145 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11804
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-02A; supply air flow rate of 570 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-02A; supply air flow rate of 570 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11806
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-02B; supply air flow rate of 570 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-02B; supply air flow rate of 570 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11808
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-03; supply air flow rate of 601 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-03; supply air flow rate of 601 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11810
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,910.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-04; supply air flow rate of 396 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-04; supply air flow rate of 396 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11812
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-05A; supply air flow rate of 450 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-05A; supply air flow rate of 450 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11814
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-05B; supply air flow rate of 450 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-05B; supply air flow rate of 450 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11816
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-06A; supply air flow rate of 693 l/s and total capacity 8.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-06A; supply air flow rate of 693 l/s and total capacity 8.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11818
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,910.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-06B; supply air flow rate of 693 l/s and total capacity 8.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-06B; supply air flow rate of 693 l/s and total capacity 8.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11820
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,910.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-07; supply air flow rate of 105 l/s and total capacity 1.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-07; supply air flow rate of 105 l/s and total capacity 1.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11822
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/219-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-08; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-08; supply air flow rate of 221 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/101",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11824
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/220",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 93220,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/220-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-09; supply air flow rate of 224 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-09; supply air flow rate of 224 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-10; supply air flow rate of 214 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-10; supply air flow rate of 214 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-11; supply air flow rate of 230 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-11; supply air flow rate of 230 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-12; supply air flow rate of 601 l/s and total capacity 7.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-12; supply air flow rate of 601 l/s and total capacity 7.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-01-13; supply air flow rate of 523 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-01-13; supply air flow rate of 523 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-02A; supply air flow rate of 235 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-02A; supply air flow rate of 235 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-02B; supply air flow rate of 270 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-02B; supply air flow rate of 270 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-02C; supply air flow rate of 305 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-02C; supply air flow rate of 305 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-58F-02D; supply air flow rate of 87 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-58F-02D; supply air flow rate of 87 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-LRF-01; supply air flow rate of 84 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-LRF-01; supply air flow rate of 84 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-LRF-02; supply air flow rate of 444 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-LRF-02; supply air flow rate of 444 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-LRF-STAIR 01; supply air flow rate of 1378 l/s and total capacity 20.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-LRF-STAIR 01; supply air flow rate of 1378 l/s and total capacity 20.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18360,
          "amount_aed": 18360,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-LRF-STAIR 02; supply air flow rate of 912 l/s and total capacity 14.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-LRF-STAIR 02; supply air flow rate of 912 l/s and total capacity 14.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/220-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-RF-02; supply air flow rate of 818 l/s and total capacity 11.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-RF-02; supply air flow rate of 818 l/s and total capacity 11.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/102",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/221",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 421340.0000000001,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/221-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-RF-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-RF-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11876
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-01; supply air flow rate of 3301 l/s and total capacity 48.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-01; supply air flow rate of 3301 l/s and total capacity 48.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 43470.000000000015,
          "amount_aed": 43470.000000000015,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11878
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,470.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-02; supply air flow rate of 5841 l/s and total capacity 85.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-02; supply air flow rate of 5841 l/s and total capacity 85.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 77130.00000000003,
          "amount_aed": 77130.00000000003,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11880
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "77,130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-03; supply air flow rate of 6199 l/s and total capacity 90.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-03; supply air flow rate of 6199 l/s and total capacity 90.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 81630.00000000004,
          "amount_aed": 81630.00000000004,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11882
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "81,630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-04; supply air flow rate of 9994 l/s and total capacity 130.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-04; supply air flow rate of 9994 l/s and total capacity 130.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 117090.00000000006,
          "amount_aed": 117090.00000000006,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11884
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "117,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-05; supply air flow rate of 3961 l/s and total capacity 51.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-05; supply air flow rate of 3961 l/s and total capacity 51.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 46350.000000000015,
          "amount_aed": 46350.000000000015,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11886
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "46,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-06; supply air flow rate of 1790 l/s and total capacity 23.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-06; supply air flow rate of 1790 l/s and total capacity 23.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21420.000000000004,
          "amount_aed": 21420.000000000004,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11888
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-07; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-07; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11890
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-08; supply air flow rate of 192 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-08; supply air flow rate of 192 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11892
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-GF-RET-09; supply air flow rate of 286 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-GF-RET-09; supply air flow rate of 286 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11894
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-01; supply air flow rate of 246 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-01; supply air flow rate of 246 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11896
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-02; supply air flow rate of 430 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-02; supply air flow rate of 430 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11898
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-03; supply air flow rate of 65 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-03; supply air flow rate of 65 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11900
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/221-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-04; supply air flow rate of 520 l/s and total capacity 7.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-04; supply air flow rate of 520 l/s and total capacity 7.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/103",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11902
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/222",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 87690,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/222-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-05; supply air flow rate of 400 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-05; supply air flow rate of 400 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11915
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B02-06; supply air flow rate of 275 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B02-06; supply air flow rate of 275 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11917
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B01-01; supply air flow rate of 484 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B01-01; supply air flow rate of 484 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11919
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B01-02; supply air flow rate of 80 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B01-02; supply air flow rate of 80 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11921
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-B01-03; supply air flow rate of 522 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-B01-03; supply air flow rate of 522 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11923
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,930.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-01A; supply air flow rate of 357 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-01A; supply air flow rate of 357 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-01B; supply air flow rate of 357 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-01B; supply air flow rate of 357 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-01C; supply air flow rate of 714 l/s and total capacity 9.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-01C; supply air flow rate of 714 l/s and total capacity 9.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-01D; supply air flow rate of 714 l/s and total capacity 9.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-01D; supply air flow rate of 714 l/s and total capacity 9.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11931
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-02; supply air flow rate of 625 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-02; supply air flow rate of 625 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11933
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-03; supply air flow rate of 362 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-03; supply air flow rate of 362 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11935
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-04; supply air flow rate of 400 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-04; supply air flow rate of 400 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-05; supply air flow rate of 125 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-05; supply air flow rate of 125 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11939
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/222-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-06; supply air flow rate of 415 l/s and total capacity 6.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-06; supply air flow rate of 415 l/s and total capacity 6.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/104",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/223",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 62870,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/223-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-07; supply air flow rate of 252 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-07; supply air flow rate of 252 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11954
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-08; supply air flow rate of 435 l/s and total capacity 8.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-08; supply air flow rate of 435 l/s and total capacity 8.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11956
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-09; supply air flow rate of 135 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-09; supply air flow rate of 135 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-11A; supply air flow rate of 216 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-11A; supply air flow rate of 216 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-11B; supply air flow rate of 216 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-11B; supply air flow rate of 216 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-12; supply air flow rate of 200 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-12; supply air flow rate of 200 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-GF-13; supply air flow rate of 410 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-GF-13; supply air flow rate of 410 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-01-01; supply air flow rate of 400 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-01-01; supply air flow rate of 400 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-01-02; supply air flow rate of 165 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-01-02; supply air flow rate of 165 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-01-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-01-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-02; supply air flow rate of 381 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-02; supply air flow rate of 381 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-03-01; supply air flow rate of 235 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-03-01; supply air flow rate of 235 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-03-02; supply air flow rate of 180 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-03-02; supply air flow rate of 180 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/223-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-03-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-03-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/105",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/224",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 67250,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/224-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-04-01; supply air flow rate of 395 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-04-01; supply air flow rate of 395 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11993
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-04-02; supply air flow rate of 245 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-04-02; supply air flow rate of 245 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11995
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-05; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-05; supply air flow rate of 265 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11997
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P01-06; supply air flow rate of 390 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P01-06; supply air flow rate of 390 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 11999
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-03-01; supply air flow rate of 440 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-03-01; supply air flow rate of 440 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12001
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-03-02; supply air flow rate of 180 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-03-02; supply air flow rate of 180 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12003
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-03-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-03-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12005
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-02; supply air flow rate of 395 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-02; supply air flow rate of 395 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-01; supply air flow rate of 492 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-01; supply air flow rate of 492 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-04; supply air flow rate of 410 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-04; supply air flow rate of 410 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-05-01; supply air flow rate of 245 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-05-01; supply air flow rate of 245 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-05-02; supply air flow rate of 205 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-05-02; supply air flow rate of 205 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-05-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-05-03; supply air flow rate of 180 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/224-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-06-01; supply air flow rate of 297 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-06-01; supply air flow rate of 297 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/106",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/225",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 91200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/225-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-06-02; supply air flow rate of 430 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-06-02; supply air flow rate of 430 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12032
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-07; supply air flow rate of 288 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-07; supply air flow rate of 288 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12034
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-08; supply air flow rate of 760 l/s and total capacity 10.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-08; supply air flow rate of 760 l/s and total capacity 10.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11110,
          "amount_aed": 11110,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12036
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-09; supply air flow rate of 404 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-09; supply air flow rate of 404 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12038
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-STAIR-01; supply air flow rate of 1327 l/s and total capacity 19.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-STAIR-01; supply air flow rate of 1327 l/s and total capacity 19.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17100,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12040
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P02-STAIR-02; supply air flow rate of 930 l/s and total capacity 14.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P02-STAIR-02; supply air flow rate of 930 l/s and total capacity 14.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12042
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-01-01; supply air flow rate of 413 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-01-01; supply air flow rate of 413 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12044
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-01-02; supply air flow rate of 162 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-01-02; supply air flow rate of 162 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12046
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-01-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12048
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-02; supply air flow rate of 407 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-02; supply air flow rate of 407 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-03-01; supply air flow rate of 338 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-03-01; supply air flow rate of 338 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12052
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-03-02; supply air flow rate of 137 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-03-02; supply air flow rate of 137 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12054
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-03-03; supply air flow rate of 268 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-03-03; supply air flow rate of 268 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/225-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-03-04; supply air flow rate of 190 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-03-04; supply air flow rate of 190 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/107",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12058
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/226",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 64400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/226-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-04; supply air flow rate of 355 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-04; supply air flow rate of 355 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-05-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-05-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-05-02; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-05-02; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-05-03; supply air flow rate of 140 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-05-03; supply air flow rate of 140 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-05-04; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-05-04; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-06-01; supply air flow rate of 211 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-06-01; supply air flow rate of 211 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-06-02; supply air flow rate of 188 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-06-02; supply air flow rate of 188 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12083
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-06-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-06-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-07A; supply air flow rate of 270 l/s and total capacity 3.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-07A; supply air flow rate of 270 l/s and total capacity 3.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-07B; supply air flow rate of 235 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-07B; supply air flow rate of 235 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-07C; supply air flow rate of 266 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-07C; supply air flow rate of 266 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12091
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-08; supply air flow rate of 422 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-08; supply air flow rate of 422 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-09A; supply air flow rate of 512 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-09A; supply air flow rate of 512 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/226-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-09B; supply air flow rate of 484 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-09B; supply air flow rate of 484 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/108",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/227",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1283160,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/227-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-09C; supply air flow rate of 484 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-09C; supply air flow rate of 484 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12110
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-P03-10; supply air flow rate of 336 l/s and total capacity 4.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-P03-10; supply air flow rate of 336 l/s and total capacity 4.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12112
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-01-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-01-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12114
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-01-02; supply air flow rate of 132 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-01-02; supply air flow rate of 132 l/s and total capacity 1.8kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12116
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-01-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-01-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12118
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "84,480.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-01-04; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-01-04; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12120
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-02; supply air flow rate of 361 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-02; supply air flow rate of 361 l/s and total capacity 5.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12122
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-03-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-03-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12124
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-03-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-03-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12126
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-03-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-03-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12128
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-04; supply air flow rate of 380 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-04; supply air flow rate of 380 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-05; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-05; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-06-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-06-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12134
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/227-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-06-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-06-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/109",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12136
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/228",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1082840,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/228-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-06-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-06-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-07; supply air flow rate of 382 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-07; supply air flow rate of 382 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12151
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-08-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-08-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "145,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-08-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-08-02; supply air flow rate of 168 l/s and total capacity 2.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-08-03; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-08-03; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-09-01; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-09-01; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "84,480.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-09-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-09-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-09-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-09-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "76,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-10A; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-10A; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "118,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-10B; supply air flow rate of 250 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-10B; supply air flow rate of 250 l/s and total capacity 3.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "24",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "84,480.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-10C; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-10C; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 66880,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "66,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T01-10C2; supply air flow rate of 699 l/s and total capacity 8.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T01-10C2; supply air flow rate of 699 l/s and total capacity 8.8kW",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 44550,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "44,550.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-01-01; supply air flow rate of 350 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-01-01; supply air flow rate of 350 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/228-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-01-02; supply air flow rate of 205 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-01-02; supply air flow rate of 205 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/110",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/229",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 63650,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/229-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-01-03; supply air flow rate of 135 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-01-03; supply air flow rate of 135 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12188
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-01-04; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-01-04; supply air flow rate of 163 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12190
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-02; supply air flow rate of 345 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-02; supply air flow rate of 345 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12192
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-03-01; supply air flow rate of 359 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-03-01; supply air flow rate of 359 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12194
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-03-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-03-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12196
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-03-03; supply air flow rate of 174 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-03-03; supply air flow rate of 174 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12198
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-04; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-04; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12200
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-05; supply air flow rate of 389 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-05; supply air flow rate of 389 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12202
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-06-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-06-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12204
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-06-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-06-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12206
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-06-03; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-06-03; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12208
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-07; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-07; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12210
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-08-01; supply air flow rate of 406 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-08-01; supply air flow rate of 406 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/229-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-08-02; supply air flow rate of 164 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-08-02; supply air flow rate of 164 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/111",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/230",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 56710,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/230-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-08-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-08-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12227
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-09-01; supply air flow rate of 210 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-09-01; supply air flow rate of 210 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12229
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-09-02; supply air flow rate of 259 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-09-02; supply air flow rate of 259 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12231
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-09-03; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-09-03; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12233
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-10-CORRIDOR 01; supply air flow rate of 224 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-10-CORRIDOR 01; supply air flow rate of 224 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-11-CORRIDOR 02; supply air flow rate of 223 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-11-CORRIDOR 02; supply air flow rate of 223 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12237
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-28F-12; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-28F-12; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T2-28F-GSM ROOM; supply air flow rate of 700 l/s and total capacity 8.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T2-28F-GSM ROOM; supply air flow rate of 700 l/s and total capacity 8.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-01-01; supply air flow rate of 403 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-01-01; supply air flow rate of 403 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-01-02; supply air flow rate of 188 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-01-02; supply air flow rate of 188 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-01-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-01-03; supply air flow rate of 160 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-02-01; supply air flow rate of 338 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-02-01; supply air flow rate of 338 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-02-02; supply air flow rate of 136 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-02-02; supply air flow rate of 136 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/230-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-02-03; supply air flow rate of 210 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-02-03; supply air flow rate of 210 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/112",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/231",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 64080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/231-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-02-04; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-02-04; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12266
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-03-01; supply air flow rate of 230 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-03-01; supply air flow rate of 230 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12268
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-03-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-03-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12270
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-03-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-03-03; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12272
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-04-01; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-04-01; supply air flow rate of 238 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12274
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-04-02; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-04-02; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12276
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-04-03; supply air flow rate of 217 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-04-03; supply air flow rate of 217 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-04-04; supply air flow rate of 260 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-04-04; supply air flow rate of 260 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12280
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-01; supply air flow rate of 58 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-01; supply air flow rate of 58 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12282
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-02; supply air flow rate of 74 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-02; supply air flow rate of 74 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-03A; supply air flow rate of 596 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-03A; supply air flow rate of 596 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12286
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-03B; supply air flow rate of 596 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-03B; supply air flow rate of 596 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-04; supply air flow rate of 381 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-04; supply air flow rate of 381 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/231-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-05; supply air flow rate of 482 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-05; supply air flow rate of 482 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/113",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12292
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/232",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 54320,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/232-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-06; supply air flow rate of 308 l/s and total capacity 4.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-06; supply air flow rate of 308 l/s and total capacity 4.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-29F-05-07; supply air flow rate of 317 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-29F-05-07; supply air flow rate of 317 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-19-01; supply air flow rate of 233 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-19-01; supply air flow rate of 233 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-19-02; supply air flow rate of 187 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-19-02; supply air flow rate of 187 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-19-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-19-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-20-01; supply air flow rate of 413 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-20-01; supply air flow rate of 413 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-20-02; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-20-02; supply air flow rate of 166 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-20-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-20-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-21-01; supply air flow rate of 342 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-21-01; supply air flow rate of 342 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-21-02; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-21-02; supply air flow rate of 213 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-21-03; supply air flow rate of 140 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-21-03; supply air flow rate of 140 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-21-04; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-21-04; supply air flow rate of 170 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-10-01; supply air flow rate of 180 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-10-01; supply air flow rate of 180 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/232-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-10-02; supply air flow rate of 170 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-10-02; supply air flow rate of 170 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/114",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/233",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1021950,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/233-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-10-03; supply air flow rate of 266 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-10-03; supply air flow rate of 266 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-11-01; supply air flow rate of 526 l/s and total capacity 7.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-11-01; supply air flow rate of 526 l/s and total capacity 7.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-11-02; supply air flow rate of 317 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-11-02; supply air flow rate of 317 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12348
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-12-01; supply air flow rate of 1185 l/s and total capacity 17.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-12-01; supply air flow rate of 1185 l/s and total capacity 17.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15300,
          "amount_aed": 15300,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,300.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-30F-12-02; supply air flow rate of 754 l/s and total capacity 11.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-30F-12-02; supply air flow rate of 754 l/s and total capacity 11.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12352
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-15-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-15-01; supply air flow rate of 347 l/s and total capacity 5kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12354
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-15-02; supply air flow rate of 206 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-15-02; supply air flow rate of 206 l/s and total capacity 2.7kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12356
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-15-03; supply air flow rate of 132 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-15-03; supply air flow rate of 132 l/s and total capacity 1.8kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-15-04; supply air flow rate of 120 l/s and total capacity 1.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-15-04; supply air flow rate of 120 l/s and total capacity 1.6kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-11-01; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-11-01; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 123750,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "123,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-17-01; supply air flow rate of 362 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-17-01; supply air flow rate of 362 l/s and total capacity 5.1kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12364
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-17-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-17-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12366
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-17-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-17-03; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/233-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-18-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-18-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/115",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12370
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/234",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1458670,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/234-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-16-01; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-16-01; supply air flow rate of 385 l/s and total capacity 5.3kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-10-01; supply air flow rate of 388 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-10-01; supply air flow rate of 388 l/s and total capacity 5.4kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-10-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-10-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-10-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-10-03; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-14-01; supply air flow rate of 376 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-14-01; supply air flow rate of 376 l/s and total capacity 5kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-13-01; supply air flow rate of 403 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-13-01; supply air flow rate of 403 l/s and total capacity 5.5kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 151250,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "151,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-13-02; supply air flow rate of 163 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-13-02; supply air flow rate of 163 l/s and total capacity 2.1kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-13-03; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-13-03; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-12-01; supply air flow rate of 209 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-12-01; supply air flow rate of 209 l/s and total capacity 3.1kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 88000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "88,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-12-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-12-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-12-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-12-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "80,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-10; supply air flow rate of 276 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-10; supply air flow rate of 276 l/s and total capacity 4kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 123750,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "123,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-11; supply air flow rate of 224 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-11; supply air flow rate of 224 l/s and total capacity 3.2kW",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 88000,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "88,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/234-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-12; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-12; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 73920,
          "amount_state": "number",
          "printed_page": "2/Q/116",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "73,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/235",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 111060,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/235-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-T02-GSM ROOM; supply air flow rate of 699 l/s and total capacity 8.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-T02-GSM ROOM; supply air flow rate of 699 l/s and total capacity 8.8kW",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 53460,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12422
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "53,460.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-01-01; supply air flow rate of 348 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-01-01; supply air flow rate of 348 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12424
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-01-02; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-01-02; supply air flow rate of 209 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12426
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-01-03; supply air flow rate of 139 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-01-03; supply air flow rate of 139 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-01-04; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-01-04; supply air flow rate of 167 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12430
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-02-01; supply air flow rate of 345 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-02-01; supply air flow rate of 345 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12432
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12434
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-02; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-03; supply air flow rate of 174 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-03; supply air flow rate of 174 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-04-01; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-04-01; supply air flow rate of 376 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-05-01; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-05-01; supply air flow rate of 386 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-01; supply air flow rate of 391 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-02; supply air flow rate of 164 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/235-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-03; supply air flow rate of 165 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/117",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/236",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57260,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/236-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-07-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-07-01; supply air flow rate of 427 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-02; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-02; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-03; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-03; supply air flow rate of 159 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-01; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-01; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-02; supply air flow rate of 181 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-03; supply air flow rate of 161 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-10-CORRIDOR 01; supply air flow rate of 276 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-10-CORRIDOR 01; supply air flow rate of 276 l/s and total capacity 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-11-CORRIDOR 02; supply air flow rate of 221 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-11-CORRIDOR 02; supply air flow rate of 221 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-12; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-12; supply air flow rate of 262 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-55F-01-01; supply air flow rate of 447 l/s and total capacity 6.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-55F-01-01; supply air flow rate of 447 l/s and total capacity 6.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-55F-01-02; supply air flow rate of 254 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-55F-01-02; supply air flow rate of 254 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-55F-01-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-55F-01-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/236-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-55F-01-04; supply air flow rate of 186 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-55F-01-04; supply air flow rate of 186 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/118",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/237",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69470,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/237-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-02; supply air flow rate of 475 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-02; supply air flow rate of 475 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12500
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-01; supply air flow rate of 462 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-01; supply air flow rate of 462 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12502
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-02; supply air flow rate of 211 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-02; supply air flow rate of 211 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12504
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-03-03; supply air flow rate of 206 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-03-03; supply air flow rate of 206 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12506
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-04; supply air flow rate of 432 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-04; supply air flow rate of 432 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12508
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-05; supply air flow rate of 471 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-05; supply air flow rate of 471 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12510
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-01; supply air flow rate of 424 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-01; supply air flow rate of 424 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12512
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-02; supply air flow rate of 184 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-02; supply air flow rate of 184 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12514
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-07; supply air flow rate of 504 l/s and total capacity 6.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-07; supply air flow rate of 504 l/s and total capacity 6.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-01; supply air flow rate of 449 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-01; supply air flow rate of 449 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-02; supply air flow rate of 181 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-02; supply air flow rate of 181 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-08-03; supply air flow rate of 193 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-08-03; supply air flow rate of 193 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/237-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-01; supply air flow rate of 223 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-01; supply air flow rate of 223 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/119",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/238",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 66140,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/238-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-02; supply air flow rate of 332 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-02; supply air flow rate of 332 l/s and total capacity 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12539
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-09-03; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-09-03; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12541
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-10-CORRIDOR 01; supply air flow rate of 392 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-10-CORRIDOR 01; supply air flow rate of 392 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12543
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-11-CORRIDOR 02; supply air flow rate of 288 l/s and total capacity 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-11-CORRIDOR 02; supply air flow rate of 288 l/s and total capacity 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-54F-12; supply air flow rate of 298 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-54F-12; supply air flow rate of 298 l/s and total capacity 3.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-01; supply air flow rate of 105 l/s and total capacity 1.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-01; supply air flow rate of 105 l/s and total capacity 1.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-02; supply air flow rate of 403 l/s and total capacity 5.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-02; supply air flow rate of 403 l/s and total capacity 5.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12551
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12553
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-04; supply air flow rate of 228 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-04; supply air flow rate of 228 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-05; supply air flow rate of 582 l/s and total capacity 7.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-05; supply air flow rate of 582 l/s and total capacity 7.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-06A; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-06A; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-06B; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-06B; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-07; supply air flow rate of 230 l/s and total capacity 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-07; supply air flow rate of 230 l/s and total capacity 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/238-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-08; supply air flow rate of 281 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-08; supply air flow rate of 281 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/120",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/239",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 104370,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/239-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-09A; supply air flow rate of 722 l/s and total capacity 9.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-09A; supply air flow rate of 722 l/s and total capacity 9.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12578
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,010.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-09B; supply air flow rate of 722 l/s and total capacity 9.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-09B; supply air flow rate of 722 l/s and total capacity 9.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12580
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,010.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-10; supply air flow rate of 644 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-10; supply air flow rate of 644 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12582
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-11A; supply air flow rate of 623 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-11A; supply air flow rate of 623 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12584
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-11B; supply air flow rate of 623 l/s and total capacity 8.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-11B; supply air flow rate of 623 l/s and total capacity 8.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12586
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,910.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-12; supply air flow rate of 138 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-12; supply air flow rate of 138 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12588
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-13; supply air flow rate of 300 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-13; supply air flow rate of 300 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12590
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-14; supply air flow rate of 255 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-14; supply air flow rate of 255 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12592
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-15; supply air flow rate of 98 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-15; supply air flow rate of 98 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12594
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-56F-16; supply air flow rate of 76 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-56F-16; supply air flow rate of 76 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12596
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-57F-01-01; supply air flow rate of 1307 l/s and total capacity 19.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-57F-01-01; supply air flow rate of 1307 l/s and total capacity 19.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17100,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12598
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-57F-01-02; supply air flow rate of 125 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-57F-01-02; supply air flow rate of 125 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12600
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-57F-01-03; supply air flow rate of 480 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-57F-01-03; supply air flow rate of 480 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12602
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/239-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-57-STAIR-02; supply air flow rate of 740 l/s and total capacity 11.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-57-STAIR-02; supply air flow rate of 740 l/s and total capacity 11.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/121",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12604
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/240",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 70780,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/240-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-58F-01-01; supply air flow rate of 915 l/s and total capacity 12.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-58F-01-01; supply air flow rate of 915 l/s and total capacity 12.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13860,
          "amount_aed": 13860,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,860.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T3-58F-01-03; supply air flow rate of 302 l/s and total capacity 4.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T3-58F-01-03; supply air flow rate of 302 l/s and total capacity 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B02-01; supply air flow rate of 248 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B02-01; supply air flow rate of 248 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12621
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B02-02; supply air flow rate of 386 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B02-02; supply air flow rate of 386 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12623
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "6,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B02-03; supply air flow rate of 91 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B02-03; supply air flow rate of 91 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12625
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B02-04; supply air flow rate of 170 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B02-04; supply air flow rate of 170 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12627
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B01-01; supply air flow rate of 319 l/s and total capacity 4.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B01-01; supply air flow rate of 319 l/s and total capacity 4.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12629
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "4,950.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B01-02; supply air flow rate of 358 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B01-02; supply air flow rate of 358 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12631
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "4,950.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-B01-03; supply air flow rate of 113 l/s and total capacity 1.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-B01-03; supply air flow rate of 113 l/s and total capacity 1.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12633
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-01; supply air flow rate of 122 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-01; supply air flow rate of 122 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12635
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-02; supply air flow rate of 524 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-02; supply air flow rate of 524 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12637
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-03; supply air flow rate of 262 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-03; supply air flow rate of 262 l/s and total capacity 3.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12639
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-04; supply air flow rate of 90 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-04; supply air flow rate of 90 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/240-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-05; supply air flow rate of 420 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-05; supply air flow rate of 420 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/122",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12643
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/241",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 79130,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/241-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-06; supply air flow rate of 451 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-06; supply air flow rate of 451 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-07A; supply air flow rate of 362 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-07A; supply air flow rate of 362 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-07B; supply air flow rate of 362 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-07B; supply air flow rate of 362 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12660
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-08A; supply air flow rate of 810 l/s and total capacity 9.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-08A; supply air flow rate of 810 l/s and total capacity 9.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12662
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-08B; supply air flow rate of 810 l/s and total capacity 9.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-08B; supply air flow rate of 810 l/s and total capacity 9.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-09; supply air flow rate of 142 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-09; supply air flow rate of 142 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-10; supply air flow rate of 236 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-10; supply air flow rate of 236 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-11A; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-11A; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-11B; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-11B; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-11C; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-11C; supply air flow rate of 514 l/s and total capacity 6.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-13; supply air flow rate of 213 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-13; supply air flow rate of 213 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12676
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-15; supply air flow rate of 693 l/s and total capacity 8.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-15; supply air flow rate of 693 l/s and total capacity 8.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12678
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-17; supply air flow rate of 106 l/s and total capacity 1.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-17; supply air flow rate of 106 l/s and total capacity 1.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12680
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/241-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-GF-18; supply air flow rate of 101 l/s and total capacity 1.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-GF-18; supply air flow rate of 101 l/s and total capacity 1.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/123",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12682
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/242",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 76050,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/242-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-01; supply air flow rate of 557 l/s and total capacity 7.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-01; supply air flow rate of 557 l/s and total capacity 7.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-02; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-02; supply air flow rate of 405 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-03-01; supply air flow rate of 380 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-03-01; supply air flow rate of 380 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-03-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-03-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-03-03; supply air flow rate of 151 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-03-03; supply air flow rate of 151 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12703
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-04-01; supply air flow rate of 360 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-04-01; supply air flow rate of 360 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-04-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-04-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12707
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-04-03; supply air flow rate of 146 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-04-03; supply air flow rate of 146 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12709
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-05A; supply air flow rate of 390 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-05A; supply air flow rate of 390 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12711
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-05B; supply air flow rate of 287 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-05B; supply air flow rate of 287 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12713
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-05C; supply air flow rate of 260 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-05C; supply air flow rate of 260 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12715
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P01-06; supply air flow rate of 497 l/s and total capacity 6.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P01-06; supply air flow rate of 497 l/s and total capacity 6.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-01; supply air flow rate of 574 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-01; supply air flow rate of 574 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/242-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-02; supply air flow rate of 445 l/s and total capacity 6.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-02; supply air flow rate of 445 l/s and total capacity 6.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/124",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/243",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 82150,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/243-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-03-01; supply air flow rate of 420 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-03-01; supply air flow rate of 420 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-03-02; supply air flow rate of 158 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-03-02; supply air flow rate of 158 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-03-03; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-03-03; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-04; supply air flow rate of 378 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-04; supply air flow rate of 378 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12740
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-05; supply air flow rate of 381 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-05; supply air flow rate of 381 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-06-01; supply air flow rate of 371 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-06-01; supply air flow rate of 371 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-06-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-06-02; supply air flow rate of 162 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-06-03; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-06-03; supply air flow rate of 169 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-07A; supply air flow rate of 326 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-07A; supply air flow rate of 326 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-07B; supply air flow rate of 322 l/s and total capacity 4.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-07B; supply air flow rate of 322 l/s and total capacity 4.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12752
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-07C; supply air flow rate of 294 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-07C; supply air flow rate of 294 l/s and total capacity 3.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12754
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-FL LOBBY; supply air flow rate of 75 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-FL LOBBY; supply air flow rate of 75 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12756
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-STAIR 01; supply air flow rate of 1069 l/s and total capacity 16.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-STAIR 01; supply air flow rate of 1069 l/s and total capacity 16.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14670,
          "amount_aed": 14670,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12758
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/243-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P02-STAIR 02; supply air flow rate of 771 l/s and total capacity 12.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P02-STAIR 02; supply air flow rate of 771 l/s and total capacity 12.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13860,
          "amount_aed": 13860,
          "amount_state": "number",
          "printed_page": "2/Q/125",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/244",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69360,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/244-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-01-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-01-01; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12773
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-01-02; supply air flow rate of 179 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-01-02; supply air flow rate of 179 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-01-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-01-03; supply air flow rate of 220 l/s and total capacity 2.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-02-01; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-02-01; supply air flow rate of 415 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-03-01; supply air flow rate of 391 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-03-01; supply air flow rate of 391 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-03-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-03-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-03-03; supply air flow rate of 153 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-03-03; supply air flow rate of 153 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-04-01; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-04-01; supply air flow rate of 348 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-05-01; supply air flow rate of 355 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-05-01; supply air flow rate of 355 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-06-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-06-01; supply air flow rate of 365 l/s and total capacity 5.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-06-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-06-02; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-06-03; supply air flow rate of 185 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-07-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-07-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/244-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-08A; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-08A; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/126",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/245",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 658670,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/245-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-08B; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-08B; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12812
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-08C; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-08C; supply air flow rate of 569 l/s and total capacity 8.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12814
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,910.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-09A; supply air flow rate of 157 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-09A; supply air flow rate of 157 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12816
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-09B; supply air flow rate of 143 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-09B; supply air flow rate of 143 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12818
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-10A; supply air flow rate of 374 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-10A; supply air flow rate of 374 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12820
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-10B; supply air flow rate of 233 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-10B; supply air flow rate of 233 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12822
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-P03-10C; supply air flow rate of 269 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-P03-10C; supply air flow rate of 269 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12824
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/245-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12826
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "84,480.00",
            "[S]": "TRUE",
            "[T]": "84480"
          }
        },
        {
          "id": "2 - Main/245-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12828
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/245-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12830
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/245-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-02-01; supply air flow rate of 406 l/s and total capacity 5.7kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12832
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/245-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12834
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/245-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12836
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "84,480.00",
            "[S]": "TRUE",
            "[T]": "84480"
          }
        },
        {
          "id": "2 - Main/245-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/127",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12838
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/246",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1543200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/246-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-03; supply air flow rate of 404 l/s and total capacity 5.6kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/246-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-04-01; supply air flow rate of 382 l/s and total capacity 5.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/246-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-04-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-04-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-04-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-05; supply air flow rate of 337 l/s and total capacity 4.7kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "118,800.00",
            "[S]": "TRUE",
            "[T]": "118800"
          }
        },
        {
          "id": "2 - Main/246-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-06; supply air flow rate of 342 l/s and total capacity 4.8kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "118,800.00",
            "[S]": "TRUE",
            "[T]": "118800"
          }
        },
        {
          "id": "2 - Main/246-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-07-01; supply air flow rate of 356 l/s and total capacity 5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/246-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-07-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-07-02; supply air flow rate of 156 l/s and total capacity 2.1kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-07-03; supply air flow rate of 147 l/s and total capacity 2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-08; supply air flow rate of 408 l/s and total capacity 5.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/246-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-09-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 145200,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "145,200.00",
            "[S]": "TRUE",
            "[T]": "145200"
          }
        },
        {
          "id": "2 - Main/246-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-09-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12873
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-09-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 76800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12875
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "76,800.00",
            "[S]": "TRUE",
            "[T]": "76800"
          }
        },
        {
          "id": "2 - Main/246-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/128",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12877
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "118,800.00",
            "[S]": "TRUE",
            "[T]": "118800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/247",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 453590,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/247-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12890
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "84,480.00",
            "[S]": "TRUE",
            "[T]": "84480"
          }
        },
        {
          "id": "2 - Main/247-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 84480,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12892
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "84,480.00",
            "[S]": "TRUE",
            "[T]": "84480"
          }
        },
        {
          "id": "2 - Main/247-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10C2; supply air flow rate of 753 l/s and total capacity 9.5kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 240240,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12894
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "240,240.00",
            "[S]": "TRUE",
            "[T]": "240240"
          }
        },
        {
          "id": "2 - Main/247-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-01-01; supply air flow rate of 220 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12896
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/247-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-01-02; supply air flow rate of 193 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12898
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/247-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-01-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12900
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/247-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-02-01; supply air flow rate of 410 l/s and total capacity 5.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12902
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/247-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12904
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/247-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-02-03; supply air flow rate of 265 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-02-03; supply air flow rate of 265 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12906
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/247-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-02-04; supply air flow rate of 179 l/s and total capacity 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/247-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-03-01; supply air flow rate of 408 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12910
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/247-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-04-01; supply air flow rate of 385 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/247-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-04-02; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-04-02; supply air flow rate of 157 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12914
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/247-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-04-03; supply air flow rate of 149 l/s and total capacity 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/129",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12916
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/248",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 329180,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/248-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-05-01; supply air flow rate of 340 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/248-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-06-01; supply air flow rate of 346 l/s and total capacity 4.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12931
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/248-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-07-01; supply air flow rate of 358 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12933
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/248-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-07-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-07-02; supply air flow rate of 155 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12935
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/248-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-07-03; supply air flow rate of 154 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/248-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-08-01; supply air flow rate of 411 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12939
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/248-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-09-01; supply air flow rate of 410 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/248-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-09-02; supply air flow rate of 178 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12943
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/248-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-09-03; supply air flow rate of 176 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12945
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/248-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10A; supply air flow rate of 325 l/s and total capacity 4.9kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 118800,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12947
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "118,800.00",
            "[S]": "TRUE",
            "[T]": "118800"
          }
        },
        {
          "id": "2 - Main/248-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10B; supply air flow rate of 250 l/s and total capacity 3.2kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3250,
          "amount_aed": 78000,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12949
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "78,000.00",
            "[S]": "TRUE",
            "[T]": "78000"
          }
        },
        {
          "id": "2 - Main/248-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-10C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 3250,
          "amount_aed": 78000,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "24",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "78,000.00",
            "[S]": "TRUE",
            "[T]": "78000"
          }
        },
        {
          "id": "2 - Main/248-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T01-28-10C2; supply air flow rate of 755 l/s and total capacity 9.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T01-28-10C2; supply air flow rate of 755 l/s and total capacity 9.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12953
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,010.00",
            "[S]": "TRUE",
            "[T]": "10010"
          }
        },
        {
          "id": "2 - Main/248-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/130",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12955
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/249",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 51460,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/249-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-02-01; supply air flow rate of 417 l/s and total capacity 5.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-02-01; supply air flow rate of 417 l/s and total capacity 5.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/249-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-02-03; supply air flow rate of 264 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/249-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/249-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12982
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12984
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-04A; supply air flow rate of 225 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-04A; supply air flow rate of 225 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-04A1; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-04A1; supply air flow rate of 56 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/249-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-04B; supply air flow rate of 219 l/s and total capacity 3.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-04B; supply air flow rate of 219 l/s and total capacity 3.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/249-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-29F-04C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-29F-04C; supply air flow rate of 261 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12992
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/249-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MCC-01; supply air flow rate of 75 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MCC-01; supply air flow rate of 75 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/131",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 12994
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/250",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 73970,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/250-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MCC-02; supply air flow rate of 59 l/s and total capacity 0.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MCC-02; supply air flow rate of 59 l/s and total capacity 0.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/250-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 01; supply air flow rate of 714 l/s and total capacity 9.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 01; supply air flow rate of 714 l/s and total capacity 9.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 10010,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,010.00",
            "[S]": "TRUE",
            "[T]": "10010"
          }
        },
        {
          "id": "2 - Main/250-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02A; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02A; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/250-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 02B; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 02B; supply air flow rate of 560 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/250-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03A; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03A; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/250-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T1-29F-MEP 03B; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T1-29F-MEP 03B; supply air flow rate of 406 l/s and total capacity 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/250-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-01-01; supply air flow rate of 219 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/250-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-01-02; supply air flow rate of 191 l/s and total capacity 2.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/250-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-01-03; supply air flow rate of 173 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/250-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-02-01; supply air flow rate of 418 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-02-01; supply air flow rate of 418 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/250-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-02-02; supply air flow rate of 145 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/250-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-02-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-02-03; supply air flow rate of 269 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/250-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-02-04; supply air flow rate of 177 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/250-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-03-01; supply air flow rate of 407 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/132",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/251",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 429810,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/251-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-03-02; supply air flow rate of 172 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13046
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/251-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-03-03; supply air flow rate of 175 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13048
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/251-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-04A; supply air flow rate of 245 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-04A; supply air flow rate of 245 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/251-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-04B; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-04B; supply air flow rate of 215 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13052
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/251-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-04C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-04C; supply air flow rate of 264 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13054
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/251-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-STAIR 01; supply air flow rate of 1046 l/s and total capacity 15.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-STAIR 01; supply air flow rate of 1046 l/s and total capacity 15.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14130,
          "amount_aed": 14130,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "14,130.00",
            "[S]": "TRUE",
            "[T]": "14130"
          }
        },
        {
          "id": "2 - Main/251-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-30F-STAIR 02; supply air flow rate of 701 l/s and total capacity 11.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-30F-STAIR 02; supply air flow rate of 701 l/s and total capacity 11.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13058
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,320.00",
            "[S]": "TRUE",
            "[T]": "12320"
          }
        },
        {
          "id": "2 - Main/251-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-01-01; supply air flow rate of 219 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-01-01; supply air flow rate of 219 l/s and total capacity 2.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13060
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/251-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-01-02; supply air flow rate of 191 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-01-02; supply air flow rate of 191 l/s and total capacity 2.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13062
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/251-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-01-03; supply air flow rate of 173 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-01-03; supply air flow rate of 173 l/s and total capacity 2.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13064
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/251-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-02-01; supply air flow rate of 406 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-02-01; supply air flow rate of 406 l/s and total capacity 4.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13066
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/251-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-02-02; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-02-02; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13068
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/251-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-02-03; supply air flow rate of 219 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-02-03; supply air flow rate of 219 l/s and total capacity 2.6kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13070
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/251-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-02-04; supply air flow rate of 177 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-02-04; supply air flow rate of 177 l/s and total capacity 2.2kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/133",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13072
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/252",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 917920,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/252-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-03; supply air flow rate of 404 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-03; supply air flow rate of 404 l/s and total capacity 4.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-04-01; supply air flow rate of 382 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-04-01; supply air flow rate of 382 l/s and total capacity 4.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-04-02; supply air flow rate of 144 l/s and total capacity 1.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-04-02; supply air flow rate of 144 l/s and total capacity 1.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-04-03; supply air flow rate of 147 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-04-03; supply air flow rate of 147 l/s and total capacity 1.8kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13091
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-05; supply air flow rate of 337 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-05; supply air flow rate of 337 l/s and total capacity 4.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-06; supply air flow rate of 342 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-06; supply air flow rate of 342 l/s and total capacity 4.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-07-01; supply air flow rate of 356 l/s and total capacity 4.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-07-01; supply air flow rate of 356 l/s and total capacity 4.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-07-02; supply air flow rate of 144 l/s and total capacity 1.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-07-02; supply air flow rate of 144 l/s and total capacity 1.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-07-03; supply air flow rate of 147 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-07-03; supply air flow rate of 147 l/s and total capacity 1.8kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-08; supply air flow rate of 408 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-08; supply air flow rate of 408 l/s and total capacity 4.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-09-01; supply air flow rate of 407 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-09-01; supply air flow rate of 407 l/s and total capacity 4.9kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 79200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "79,200.00",
            "[S]": "TRUE",
            "[T]": "79200"
          }
        },
        {
          "id": "2 - Main/252-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-09-02; supply air flow rate of 172 l/s and total capacity 2.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-09-03; supply air flow rate of 175 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-09-03; supply air flow rate of 175 l/s and total capacity 2.1kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/252-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-10A; supply air flow rate of 277 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-10A; supply air flow rate of 277 l/s and total capacity 3.3kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 56320,
          "amount_state": "number",
          "printed_page": "2/Q/134",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "56,320.00",
            "[S]": "TRUE",
            "[T]": "56320"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/253",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 176450,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/253-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-10B; supply air flow rate of 222 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-10B; supply air flow rate of 222 l/s and total capacity 2.7kW",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 51200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13124
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,200.00",
            "[S]": "TRUE",
            "[T]": "51200"
          }
        },
        {
          "id": "2 - Main/253-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-10C; supply air flow rate of 261 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-10C; supply air flow rate of 261 l/s and total capacity 3.2kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 42240,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13126
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,240.00",
            "[S]": "TRUE",
            "[T]": "42240"
          }
        },
        {
          "id": "2 - Main/253-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-10C2; supply air flow rate of 753 l/s and total capacity 9.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-10C2; supply air flow rate of 753 l/s and total capacity 9.4kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 10010,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13128
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "40,040.00",
            "[S]": "TRUE",
            "[T]": "40040"
          }
        },
        {
          "id": "2 - Main/253-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-01-01; supply air flow rate of 220 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-01-01; supply air flow rate of 220 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-01-02; supply air flow rate of 193 l/s and total capacity 2.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-01-02; supply air flow rate of 193 l/s and total capacity 2.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-01-03; supply air flow rate of 175 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-01-03; supply air flow rate of 175 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13134
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-02-01; supply air flow rate of 410 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-02-01; supply air flow rate of 410 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13136
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/253-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-02-02; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-02-02; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13138
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-02-03; supply air flow rate of 265 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-02-03; supply air flow rate of 265 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13140
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/253-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-02-04; supply air flow rate of 179 l/s and total capacity 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-02-04; supply air flow rate of 179 l/s and total capacity 2.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13142
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-03-01; supply air flow rate of 408 l/s and total capacity 5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-03-01; supply air flow rate of 408 l/s and total capacity 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13144
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/253-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-04-01; supply air flow rate of 385 l/s and total capacity 4.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-04-01; supply air flow rate of 385 l/s and total capacity 4.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13146
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/253-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-04-02; supply air flow rate of 157 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-04-02; supply air flow rate of 157 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13148
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/253-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-04-03; supply air flow rate of 149 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-04-03; supply air flow rate of 149 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/135",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13150
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/254",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57040,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/254-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-05-01; supply air flow rate of 340 l/s and total capacity 4.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-05-01; supply air flow rate of 340 l/s and total capacity 4.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/254-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-06-01; supply air flow rate of 346 l/s and total capacity 4.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-06-01; supply air flow rate of 346 l/s and total capacity 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/254-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-07-01; supply air flow rate of 358 l/s and total capacity 4.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-07-01; supply air flow rate of 358 l/s and total capacity 4.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/254-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-07-02; supply air flow rate of 155 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-07-02; supply air flow rate of 155 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-07-03; supply air flow rate of 154 l/s and total capacity 1.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-07-03; supply air flow rate of 154 l/s and total capacity 1.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-08-01; supply air flow rate of 411 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-08-01; supply air flow rate of 411 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/254-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-09-01; supply air flow rate of 410 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-09-01; supply air flow rate of 410 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/254-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-09-02; supply air flow rate of 178 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-09-02; supply air flow rate of 178 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13177
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-09-03; supply air flow rate of 176 l/s and total capacity 2.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-09-03; supply air flow rate of 176 l/s and total capacity 2.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13179
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-10A; supply air flow rate of 284 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-10A; supply air flow rate of 284 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/254-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-10B; supply air flow rate of 226 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-10B; supply air flow rate of 226 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T02-49-10C; supply air flow rate of 263 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T02-49-10C; supply air flow rate of 263 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/254-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-01; supply air flow rate of 99 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-01; supply air flow rate of 99 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/254-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-02A; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-02A; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/136",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/255",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 78030,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/255-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-02B; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-02B; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13202
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/255-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-03; supply air flow rate of 479 l/s and total capacity 5.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-03; supply air flow rate of 479 l/s and total capacity 5.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13204
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/255-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-04A; supply air flow rate of 565 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-04A; supply air flow rate of 565 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13206
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/255-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-04B; supply air flow rate of 565 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-04B; supply air flow rate of 565 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13208
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/255-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-05; supply air flow rate of 74 l/s and total capacity 0.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-05; supply air flow rate of 74 l/s and total capacity 0.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13210
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/255-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-06; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-06; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/255-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-07; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-07; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/255-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-08; supply air flow rate of 272 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-08; supply air flow rate of 272 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/255-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-01-09; supply air flow rate of 546 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-01-09; supply air flow rate of 546 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/255-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-01; supply air flow rate of 98 l/s and total capacity 1.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-01; supply air flow rate of 98 l/s and total capacity 1.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13220
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/255-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-02A; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-02A; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/255-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-02B; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-02B; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/255-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-03; supply air flow rate of 495 l/s and total capacity 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-03; supply air flow rate of 495 l/s and total capacity 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/255-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-04A; supply air flow rate of 550 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-04A; supply air flow rate of 550 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/137",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/256",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 68450,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/256-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-04B; supply air flow rate of 550 l/s and total capacity 6.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-04B; supply air flow rate of 550 l/s and total capacity 6.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/256-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-05; supply air flow rate of 74 l/s and total capacity 0.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-05; supply air flow rate of 74 l/s and total capacity 0.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/256-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-06; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-06; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/256-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-07; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-07; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/256-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-08; supply air flow rate of 272 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-08; supply air flow rate of 272 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/256-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-02-09; supply air flow rate of 503 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-02-09; supply air flow rate of 503 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/256-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-03A; supply air flow rate of 295 l/s and total capacity 3.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-03A; supply air flow rate of 295 l/s and total capacity 3.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/256-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-03B; supply air flow rate of 264 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-03B; supply air flow rate of 264 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/256-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-T03-03C; supply air flow rate of 270 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-T03-03C; supply air flow rate of 270 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13257
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/256-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-01; supply air flow rate of 106 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-01; supply air flow rate of 106 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/256-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-02A; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-02A; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13261
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/256-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-02B; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-02B; supply air flow rate of 432 l/s and total capacity 5.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13263
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/256-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-03; supply air flow rate of 506 l/s and total capacity 6.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-03; supply air flow rate of 506 l/s and total capacity 6.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/256-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-04A; supply air flow rate of 565 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-04A; supply air flow rate of 565 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/138",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/257",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 75190,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/257-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-04B; supply air flow rate of 565 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-04B; supply air flow rate of 565 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13280
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/257-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-05; supply air flow rate of 85 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-05; supply air flow rate of 85 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13282
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/257-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-06; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-06; supply air flow rate of 209 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/257-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-07; supply air flow rate of 212 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-07; supply air flow rate of 212 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13286
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/257-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-08; supply air flow rate of 268 l/s and total capacity 3.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-08; supply air flow rate of 268 l/s and total capacity 3.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/257-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-01-09; supply air flow rate of 590 l/s and total capacity 7.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-01-09; supply air flow rate of 590 l/s and total capacity 7.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/257-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-01; supply air flow rate of 110 l/s and total capacity 1.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-01; supply air flow rate of 110 l/s and total capacity 1.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13292
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/257-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-02A; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-02A; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13294
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/257-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-02B; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-02B; supply air flow rate of 431 l/s and total capacity 5.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/257-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-03; supply air flow rate of 543 l/s and total capacity 6.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-03; supply air flow rate of 543 l/s and total capacity 6.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13298
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/257-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-04A; supply air flow rate of 590 l/s and total capacity 7.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-04A; supply air flow rate of 590 l/s and total capacity 7.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13300
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/257-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-04B; supply air flow rate of 590 l/s and total capacity 7.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-04B; supply air flow rate of 590 l/s and total capacity 7.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13302
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/257-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-05; supply air flow rate of 92 l/s and total capacity 1.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-05; supply air flow rate of 92 l/s and total capacity 1.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/257-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-06; supply air flow rate of 211 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-06; supply air flow rate of 211 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/139",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13306
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/258",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 82410,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/258-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-07; supply air flow rate of 227 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-07; supply air flow rate of 227 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/258-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-08; supply air flow rate of 273 l/s and total capacity 3.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-08; supply air flow rate of 273 l/s and total capacity 3.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/258-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-02-09; supply air flow rate of 578 l/s and total capacity 7.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-02-09; supply air flow rate of 578 l/s and total capacity 7.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/258-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-03A; supply air flow rate of 478 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-03A; supply air flow rate of 478 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/258-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-03B; supply air flow rate of 321 l/s and total capacity 3.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-03B; supply air flow rate of 321 l/s and total capacity 3.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/258-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-53-03C; supply air flow rate of 298 l/s and total capacity 3.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-53-03C; supply air flow rate of 298 l/s and total capacity 3.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/258-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-01; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-01; supply air flow rate of 145 l/s and total capacity 1.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/258-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-02A; supply air flow rate of 570 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-02A; supply air flow rate of 570 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/258-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-02B; supply air flow rate of 570 l/s and total capacity 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-02B; supply air flow rate of 570 l/s and total capacity 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/258-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-03; supply air flow rate of 601 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-03; supply air flow rate of 601 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/258-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-04; supply air flow rate of 396 l/s and total capacity 4.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-04; supply air flow rate of 396 l/s and total capacity 4.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/258-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-05A; supply air flow rate of 450 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-05A; supply air flow rate of 450 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/258-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-05B; supply air flow rate of 450 l/s and total capacity 5.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-05B; supply air flow rate of 450 l/s and total capacity 5.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/258-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-06A; supply air flow rate of 693 l/s and total capacity 8.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-06A; supply air flow rate of 693 l/s and total capacity 8.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/140",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,910.00",
            "[S]": "TRUE",
            "[T]": "8910"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/259",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 76740,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/259-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-06B; supply air flow rate of 693 l/s and total capacity 8.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-06B; supply air flow rate of 693 l/s and total capacity 8.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8910,
          "amount_aed": 8910,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,910.00",
            "[S]": "TRUE",
            "[T]": "8910"
          }
        },
        {
          "id": "2 - Main/259-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-07; supply air flow rate of 105 l/s and total capacity 1.3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-07; supply air flow rate of 105 l/s and total capacity 1.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-08; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-08; supply air flow rate of 221 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-09; supply air flow rate of 224 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-09; supply air flow rate of 224 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13364
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-10; supply air flow rate of 214 l/s and total capacity 2.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-10; supply air flow rate of 214 l/s and total capacity 2.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13366
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-11; supply air flow rate of 230 l/s and total capacity 2.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-11; supply air flow rate of 230 l/s and total capacity 2.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-12; supply air flow rate of 601 l/s and total capacity 7.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-12; supply air flow rate of 601 l/s and total capacity 7.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13370
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,360.00",
            "[S]": "TRUE",
            "[T]": "8360"
          }
        },
        {
          "id": "2 - Main/259-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-01-13; supply air flow rate of 523 l/s and total capacity 6.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-01-13; supply air flow rate of 523 l/s and total capacity 6.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6930,
          "amount_aed": 6930,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13372
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,930.00",
            "[S]": "TRUE",
            "[T]": "6930"
          }
        },
        {
          "id": "2 - Main/259-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-02A; supply air flow rate of 285 l/s and total capacity 4.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-02A; supply air flow rate of 285 l/s and total capacity 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4950,
          "amount_aed": 4950,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13374
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,950.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/259-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-02B; supply air flow rate of 270 l/s and total capacity 3.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-02B; supply air flow rate of 270 l/s and total capacity 3.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13376
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/259-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-54F-02C; supply air flow rate of 305 l/s and total capacity 3.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-54F-02C; supply air flow rate of 305 l/s and total capacity 3.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3520,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13378
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/259-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-LRF-01; supply air flow rate of 84 l/s and total capacity 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-LRF-01; supply air flow rate of 84 l/s and total capacity 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13380
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/259-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-LRF-02; supply air flow rate of 444 l/s and total capacity 5.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-LRF-02; supply air flow rate of 444 l/s and total capacity 5.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6050,
          "amount_aed": 6050,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13382
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,050.00",
            "[S]": "TRUE",
            "[T]": "6050"
          }
        },
        {
          "id": "2 - Main/259-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-55F-STAIR 01; supply air flow rate of 1385 l/s and total capacity 17.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-55F-STAIR 01; supply air flow rate of 1385 l/s and total capacity 17.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15300,
          "amount_aed": 15300,
          "amount_state": "number",
          "printed_page": "2/Q/141",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13384
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "15,300.00",
            "[S]": "TRUE",
            "[T]": "15300"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/260",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1295430,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/260-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-55F-STAIR 02; supply air flow rate of 886 l/s and total capacity 11.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-55F-STAIR 02; supply air flow rate of 886 l/s and total capacity 11.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,320.00",
            "[S]": "TRUE",
            "[T]": "12320"
          }
        },
        {
          "id": "2 - Main/260-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-RF-02; supply air flow rate of 818 l/s and total capacity 11.1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-RF-02; supply air flow rate of 818 l/s and total capacity 11.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12320,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,320.00",
            "[S]": "TRUE",
            "[T]": "12320"
          }
        },
        {
          "id": "2 - Main/260-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete"
          ],
          "own_description": "T4-RF-03; supply air flow rate of 220 l/s and total capacity 2.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Fan coil units; including cooling coil, fan, motor, drain pan, filters, control panel, thermostat, all necessary electrical wirings, BMS/DDC integration, supports, vibration isolators/rubber mount, flexible connectors, expansion anchors. threaded hanger rods, fittings and accessories; complete — T4-RF-03; supply air flow rate of 220 l/s and total capacity 2.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/260-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T4-GF-AHU-01; total cooling load of 29.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T4-GF-AHU-01; total cooling load of 29.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36000,
          "amount_aed": 36000,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/260-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T4-GF-AHU-02; total cooling load of 27.7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T4-GF-AHU-02; total cooling load of 27.7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 33600,
          "amount_aed": 33600,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/260-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T1-RF-AHU 01A / B; total cooling load of 35.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T1-RF-AHU 01A / B; total cooling load of 35.5kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 43200,
          "amount_aed": 86400,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "86,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-86400"
          }
        },
        {
          "id": "2 - Main/260-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T2-RF-AHU 01A / B; total cooling load of 35.6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T2-RF-AHU 01A / B; total cooling load of 35.6kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 43200,
          "amount_aed": 86400,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "86,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/260-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T3-RF-AHU 01A / B; total cooling load of 36.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T3-RF-AHU 01A / B; total cooling load of 36.4kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 43200,
          "amount_aed": 86400,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "86,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/260-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete"
          ],
          "own_description": "T4-RF-AHU 01A / B; total cooling load of 36.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Air-handling unit; including unit casings, inspection access panels, condensate drain pans, variable frequency controllers, coils, dampers, necessary electrical wiring, flexible connectors, fixing materials, accessories; complete — T4-RF-AHU 01A / B; total cooling load of 36.4kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 43200,
          "amount_aed": 86400,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "86,400.00",
            "[S]": "TRUE",
            "[T]": "86400"
          }
        },
        {
          "id": "2 - Main/260-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-01F-FAHU; supply air flow 8,466.5l/s, total cooling capacity of 365.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T1-01F-FAHU; supply air flow 8,466.5l/s, total cooling capacity of 365.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 361350,
          "amount_aed": 361350,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13419
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "361,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/260-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-29F-FAHU; supply air flow 11,754.5l/s, total cooling capacity of 495.5kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T1-29F-FAHU; supply air flow 11,754.5l/s, total cooling capacity of 495.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 491040,
          "amount_aed": 491040,
          "amount_state": "number",
          "printed_page": "2/Q/142",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "491,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-491040"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/261",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 11237970,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/261-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T1-51F-FAHU; supply air flow 13,434l/s, total cooling capacity of 537.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T1-51F-FAHU; supply air flow 13,434l/s, total cooling capacity of 537.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 531630,
          "amount_aed": 531630,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13434
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "531,630.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-531630"
          }
        },
        {
          "id": "2 - Main/261-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-01F-FAHU; supply air flow 10,010.5l/s, total cooling capacity of 359.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T2-01F-FAHU; supply air flow 10,010.5l/s, total cooling capacity of 359.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 356400,
          "amount_aed": 356400,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "356,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-29F-FAHU; supply air flow 10,945l/s, total cooling capacity of 468.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T2-29F-FAHU; supply air flow 10,945l/s, total cooling capacity of 468.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 464310,
          "amount_aed": 464310,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "464,310.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T2-59F-FAHU; supply air flow 17,000l/s, total cooling capacity of 677.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T2-59F-FAHU; supply air flow 17,000l/s, total cooling capacity of 677.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 671220,
          "amount_aed": 671220,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "671,220.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-01F-FAHU; supply air flow 9,457.5l/s, total cooling capacity of 397.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T3-01F-FAHU; supply air flow 9,457.5l/s, total cooling capacity of 397.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 394020,
          "amount_aed": 394020,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "394,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-29F-FAHU; supply air flow 10,278.5l/s, total cooling capacity of 438.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T3-29F-FAHU; supply air flow 10,278.5l/s, total cooling capacity of 438.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 434610,
          "amount_aed": 434610,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "434,610.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T3-57F-FAHU; supply air flow 16,205l/s, total cooling capacity of 637.4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T3-57F-FAHU; supply air flow 16,205l/s, total cooling capacity of 637.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 630630,
          "amount_aed": 630630,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "630,630.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-01F-FAHU; supply air flow 8,375.5l/s, total cooling capacity of 332.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T4-01F-FAHU; supply air flow 8,375.5l/s, total cooling capacity of 332.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 328680,
          "amount_aed": 328680,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "328,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/261-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-29F-FAHU; supply air flow 11,085l/s, total cooling capacity of 432.8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T4-29F-FAHU; supply air flow 11,085l/s, total cooling capacity of 432.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 428670,
          "amount_aed": 428670,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13450
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "428,670.00",
            "[S]": "TRUE",
            "[T]": "428670"
          }
        },
        {
          "id": "2 - Main/261-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "T4-55F-FAHU; supply air flow 15,299l/s, total cooling capacity of 577.9kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air handling unit; including anti-vibration neoprene pad, flexible connections, brackets, supports, accessories and all ancillary works as necessary — T4-55F-FAHU; supply air flow 15,299l/s, total cooling capacity of 577.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 572220,
          "amount_aed": 572220,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13452
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "572,220.00",
            "[S]": "TRUE",
            "[T]": "572220"
          }
        },
        {
          "id": "2 - Main/261-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ventilation installation",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fresh air duct (FAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ventilation installation — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Fresh air duct (FAD)",
          "quantity": 11053,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 2321130,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13458
          },
          "extra_columns": {
            "Basement [C]": "274",
            "GF & Podium [D]": "2,373",
            "Tower 1 [E]": "2,000",
            "Tower 2 [F]": "2,130",
            "Tower 3 [G]": "2,195",
            "Tower 4 [H]": "2,081",
            "TOTAL QTY [I]": "11,053",
            "BASEMENTS [M]": "57,540.00",
            "GF & PODIUM [N]": "498,330.00",
            "TOWER 1 [O]": "420,000.00",
            "TOWER 2 [P]": "447,300.00",
            "TOWER 3 [Q]": "460,950.00",
            "TOWER 4 [R]": "437,010.00",
            "[S]": "TRUE",
            "[T]": "17010"
          }
        },
        {
          "id": "2 - Main/261-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ventilation installation",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Extract air duct (EAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ventilation installation — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Extract air duct (EAD)",
          "quantity": 19545,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 4104450,
          "amount_state": "number",
          "printed_page": "2/Q/143",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13460
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,273",
            "Tower 1 [E]": "3,817",
            "Tower 2 [F]": "4,351",
            "Tower 3 [G]": "4,985",
            "Tower 4 [H]": "4,119",
            "TOTAL QTY [I]": "19,545",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "477,330.00",
            "TOWER 1 [O]": "801,570.00",
            "TOWER 2 [P]": "913,710.00",
            "TOWER 3 [Q]": "1,046,850.00",
            "TOWER 4 [R]": "864,990.00",
            "[S]": "TRUE",
            "[T]": "63420"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/262",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 190965,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/262-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ventilation installation",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "General extract air duct (GED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ventilation installation — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — General extract air duct (GED)",
          "quantity": 389,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 81690,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "127",
            "Tower 1 [E]": "62",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "78",
            "Tower 4 [H]": "69",
            "TOTAL QTY [I]": "389",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,670.00",
            "TOWER 1 [O]": "13,020.00",
            "TOWER 2 [P]": "11,130.00",
            "TOWER 3 [Q]": "16,380.00",
            "TOWER 4 [R]": "14,490.00",
            "[S]": "TRUE",
            "[T]": "1470"
          }
        },
        {
          "id": "2 - Main/262-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ventilation installation",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Exhaust duct (SWPED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ventilation installation — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Exhaust duct (SWPED)",
          "quantity": 62,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 13020,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13475
          },
          "extra_columns": {
            "Basement [C]": "62",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "62",
            "BASEMENTS [M]": "13,020.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ventilation installation",
            "Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary"
          ],
          "own_description": "Exhaust (SPED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ventilation installation — Galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, 25mm GI angle brackets, duct access panel, complete with fittings, fixings materials, sealants, gaskets, duct liners, accessories and all ancillary works as necessary — Exhaust (SPED)",
          "quantity": 87,
          "unit": "m2",
          "rate_aed": 210,
          "amount_aed": 18270,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "87",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "100 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 100 x 100mm",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 780,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13483
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "120.00",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "60.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "150 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 150 x 100mm",
          "quantity": 173,
          "unit": "Nr.",
          "rate_aed": 75,
          "amount_aed": 12975,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13485
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "49",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "173",
            "BASEMENTS [M]": "450.00",
            "GF & PODIUM [N]": "2,025.00",
            "TOWER 1 [O]": "3,675.00",
            "TOWER 2 [P]": "1,575.00",
            "TOWER 3 [Q]": "3,750.00",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE",
            "[T]": "-2175"
          }
        },
        {
          "id": "2 - Main/262-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 150 x 150mm",
          "quantity": 117,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 10530,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13487
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "35",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "47",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "1,350.00",
            "GF & PODIUM [N]": "990.00",
            "TOWER 1 [O]": "360.00",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "450.00",
            "TOWER 4 [R]": "4,230.00",
            "[S]": "TRUE",
            "[T]": "3870"
          }
        },
        {
          "id": "2 - Main/262-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 200 x 150mm",
          "quantity": 36,
          "unit": "Nr.",
          "rate_aed": 105,
          "amount_aed": 3780,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13489
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "315.00",
            "GF & PODIUM [N]": "945.00",
            "TOWER 1 [O]": "1,890.00",
            "TOWER 2 [P]": "210.00",
            "TOWER 3 [Q]": "420.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1890"
          }
        },
        {
          "id": "2 - Main/262-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 200 x 200mm",
          "quantity": 283,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 33960,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13491
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "70",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "89",
            "TOTAL QTY [I]": "283",
            "BASEMENTS [M]": "240.00",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "120.00",
            "TOWER 2 [P]": "8,400.00",
            "TOWER 3 [Q]": "12,360.00",
            "TOWER 4 [R]": "10,680.00",
            "[S]": "TRUE",
            "[T]": "10560"
          }
        },
        {
          "id": "2 - Main/262-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 250 x 200mm",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 135,
          "amount_aed": 3375,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13493
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "270.00",
            "GF & PODIUM [N]": "2,430.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "405.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "270.00",
            "[S]": "TRUE",
            "[T]": "270"
          }
        },
        {
          "id": "2 - Main/262-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 250 x 250mm",
          "quantity": 43,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 6450,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6450"
          }
        },
        {
          "id": "2 - Main/262-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-150"
          }
        },
        {
          "id": "2 - Main/262-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 250mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 165,
          "amount_aed": 1320,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13499
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "825.00",
            "TOWER 1 [O]": "165.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "330.00",
            "[S]": "TRUE",
            "[T]": "165"
          }
        },
        {
          "id": "2 - Main/262-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 300 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13501
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "180.00",
            "TOWER 2 [P]": "180.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "180.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 200mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 165,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "330.00",
            "TOWER 1 [O]": "165.00",
            "TOWER 2 [P]": "165.00",
            "TOWER 3 [Q]": "165.00",
            "TOWER 4 [R]": "165.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13505
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "180.00",
            "[S]": "TRUE",
            "[T]": "180"
          }
        },
        {
          "id": "2 - Main/262-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 195,
          "amount_aed": 585,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "195.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "390.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 350 x 350mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13509
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,050.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/262-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/Q/144",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13511
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/263",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 29640,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/263-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 630,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "400 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 400 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "210.00",
            "[S]": "TRUE",
            "[T]": "210"
          }
        },
        {
          "id": "2 - Main/263-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 400mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 255,
          "amount_aed": 2550,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "510.00",
            "TOWER 1 [O]": "510.00",
            "TOWER 2 [P]": "510.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,020.00",
            "[S]": "TRUE",
            "[T]": "510"
          }
        },
        {
          "id": "2 - Main/263-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 450 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 270,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13534
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "270.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-270"
          }
        },
        {
          "id": "2 - Main/263-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13536
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "210.00",
            "[S]": "TRUE",
            "[T]": "210"
          }
        },
        {
          "id": "2 - Main/263-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 225,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13538
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "225.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 255,
          "amount_aed": 255,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13540
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "255.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 400mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2970,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13542
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "810.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-810"
          }
        },
        {
          "id": "2 - Main/263-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 450mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 285,
          "amount_aed": 855,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13544
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "855.00",
            "[S]": "TRUE",
            "[T]": "855"
          }
        },
        {
          "id": "2 - Main/263-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "500 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 500 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 255,
          "amount_aed": 765,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "255.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "510.00",
            "[S]": "TRUE",
            "[T]": "510"
          }
        },
        {
          "id": "2 - Main/263-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 350mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2430,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13550
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "270.00",
            "TOWER 2 [P]": "540.00",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "1,350.00",
            "[S]": "TRUE",
            "[T]": "1080"
          }
        },
        {
          "id": "2 - Main/263-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 400mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 285,
          "amount_aed": 2565,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13552
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "285.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "570.00",
            "TOWER 3 [Q]": "1,140.00",
            "TOWER 4 [R]": "570.00",
            "[S]": "TRUE",
            "[T]": "570"
          }
        },
        {
          "id": "2 - Main/263-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13554
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 500mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,260.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1260"
          }
        },
        {
          "id": "2 - Main/263-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "550 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 550 x 550mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "330.00",
            "TOWER 2 [P]": "1,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "990.00",
            "[S]": "TRUE",
            "[T]": "660"
          }
        },
        {
          "id": "2 - Main/263-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 255,
          "amount_aed": 510,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "255.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "255.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 350mm",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 285,
          "amount_aed": 5415,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "285.00",
            "TOWER 2 [P]": "855.00",
            "TOWER 3 [Q]": "3,990.00",
            "TOWER 4 [R]": "285.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/263-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 400mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "300.00",
            "TOWER 3 [Q]": "600.00",
            "TOWER 4 [R]": "900.00",
            "[S]": "TRUE",
            "[T]": "300"
          }
        },
        {
          "id": "2 - Main/263-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 500mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 1650,
          "amount_state": "number",
          "printed_page": "2/Q/145",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13566
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "330.00",
            "[S]": "TRUE",
            "[T]": "330"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/264",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 32430,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/264-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 550mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 2415,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "345.00",
            "TOWER 3 [Q]": "690.00",
            "TOWER 4 [R]": "1,380.00",
            "[S]": "TRUE",
            "[T]": "1380"
          }
        },
        {
          "id": "2 - Main/264-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 600 x 600mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 350mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE",
            "[T]": "600"
          }
        },
        {
          "id": "2 - Main/264-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "945.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "315.00",
            "[S]": "TRUE",
            "[T]": "315"
          }
        },
        {
          "id": "2 - Main/264-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 450mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "990.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "690.00",
            "[S]": "TRUE",
            "[T]": "690"
          }
        },
        {
          "id": "2 - Main/264-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 550mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 1800,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "650 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 650 x 600mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "375.00",
            "TOWER 2 [P]": "375.00",
            "TOWER 3 [Q]": "1,125.00",
            "TOWER 4 [R]": "375.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 315,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "315.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 400mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 2970,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13597
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,650.00",
            "[S]": "TRUE",
            "[T]": "1650"
          }
        },
        {
          "id": "2 - Main/264-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 450mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 2070,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,035.00",
            "TOWER 4 [R]": "1,035.00",
            "[S]": "TRUE",
            "[T]": "1035"
          }
        },
        {
          "id": "2 - Main/264-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 500mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 550mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "700 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 700 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 390,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "390.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-390"
          }
        },
        {
          "id": "2 - Main/264-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "750 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 750 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 1035,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "345.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "690.00",
            "[S]": "TRUE",
            "[T]": "690"
          }
        },
        {
          "id": "2 - Main/264-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "750 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 750 x 450mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "750 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 750 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "375.00",
            "[S]": "TRUE",
            "[T]": "375"
          }
        },
        {
          "id": "2 - Main/264-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "750 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 750 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 345,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "345.00",
            "TOWER 2 [P]": "345.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-345"
          }
        },
        {
          "id": "2 - Main/264-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 400mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,520.00",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "360"
          }
        },
        {
          "id": "2 - Main/264-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 450mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/264-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "800 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 800 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 435,
          "amount_aed": 435,
          "amount_state": "number",
          "printed_page": "2/Q/146",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "435.00",
            "[S]": "TRUE",
            "[T]": "435"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/265",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 25455,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/265-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "850 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 850 x 350mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13634
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "2,520.00",
            "TOWER 4 [R]": "720.00",
            "[S]": "TRUE",
            "[T]": "720"
          }
        },
        {
          "id": "2 - Main/265-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "850 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 850 x 400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13636
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "375.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "850 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 850 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 1950,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13638
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "850 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 850 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13640
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-450"
          }
        },
        {
          "id": "2 - Main/265-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "900 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 900 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 375,
          "amount_aed": 750,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13642
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-750"
          }
        },
        {
          "id": "2 - Main/265-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "900 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 900 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 1560,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13644
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "390.00",
            "[S]": "TRUE",
            "[T]": "390"
          }
        },
        {
          "id": "2 - Main/265-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "900 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 900 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 405,
          "amount_aed": 810,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13646
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "405.00",
            "TOWER 2 [P]": "405.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-405"
          }
        },
        {
          "id": "2 - Main/265-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "900 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 900 x 750mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 495,
          "amount_aed": 495,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13648
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "495.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "950 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 950 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13650
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-420"
          }
        },
        {
          "id": "2 - Main/265-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "950 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 950 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13652
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "950 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 950 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 495,
          "amount_aed": 495,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13654
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "495.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1000 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1000 x 400mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1000 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1000 x 750mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 525,
          "amount_aed": 525,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "525.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-525"
          }
        },
        {
          "id": "2 - Main/265-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1000 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1000 x 900mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 570,
          "amount_aed": 570,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13660
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "570.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1050 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1050 x 350mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 2520,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13662
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1050 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1050 x 500mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 465,
          "amount_aed": 2790,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,790.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1050 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1050 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1100 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1100 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE",
            "[T]": "480"
          }
        },
        {
          "id": "2 - Main/265-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1100 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1100 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 510,
          "amount_aed": 510,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "510.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1150 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1150 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "480.00",
            "TOWER 3 [Q]": "480.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/265-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1200 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1200 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 495,
          "amount_aed": 495,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "495.00",
            "[S]": "TRUE",
            "[T]": "495"
          }
        },
        {
          "id": "2 - Main/265-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1200 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1200 x 500mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 510,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/Q/147",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13676
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/266",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 113526,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/266-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1250 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1250 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 525,
          "amount_aed": 525,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "525.00",
            "[S]": "TRUE",
            "[T]": "525"
          }
        },
        {
          "id": "2 - Main/266-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1300 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1300 x 550mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 555,
          "amount_aed": 1665,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,665.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1300 x 1100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1300 x 1100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 720,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1400 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1400 x 900mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 690,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "690.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-690"
          }
        },
        {
          "id": "2 - Main/266-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Fire damper (FD)"
          ],
          "own_description": "1500 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Fire damper (FD) — 1500 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "100 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 100 x 100mm",
          "quantity": 59,
          "unit": "Nr.",
          "rate_aed": 56,
          "amount_aed": 3304,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13701
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "59",
            "BASEMENTS [M]": "448.00",
            "GF & PODIUM [N]": "2,072.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "112.00",
            "TOWER 3 [Q]": "224.00",
            "TOWER 4 [R]": "448.00",
            "[S]": "TRUE",
            "[T]": "448"
          }
        },
        {
          "id": "2 - Main/266-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "150 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 150 x 100mm",
          "quantity": 443,
          "unit": "Nr.",
          "rate_aed": 70,
          "amount_aed": 31010,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13703
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "64",
            "Tower 3 [G]": "111",
            "Tower 4 [H]": "97",
            "TOTAL QTY [I]": "443",
            "BASEMENTS [M]": "140.00",
            "GF & PODIUM [N]": "5,250.00",
            "TOWER 1 [O]": "6,580.00",
            "TOWER 2 [P]": "4,480.00",
            "TOWER 3 [Q]": "7,770.00",
            "TOWER 4 [R]": "6,790.00",
            "[S]": "TRUE",
            "[T]": "210"
          }
        },
        {
          "id": "2 - Main/266-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 150 x 150mm",
          "quantity": 119,
          "unit": "Nr.",
          "rate_aed": 84,
          "amount_aed": 9996,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13705
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "34",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "119",
            "BASEMENTS [M]": "1,260.00",
            "GF & PODIUM [N]": "2,184.00",
            "TOWER 1 [O]": "1,092.00",
            "TOWER 2 [P]": "2,856.00",
            "TOWER 3 [Q]": "756.00",
            "TOWER 4 [R]": "1,848.00",
            "[S]": "TRUE",
            "[T]": "756"
          }
        },
        {
          "id": "2 - Main/266-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 150mm",
          "quantity": 75,
          "unit": "Nr.",
          "rate_aed": 98,
          "amount_aed": 7350,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13707
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "196.00",
            "GF & PODIUM [N]": "2,450.00",
            "TOWER 1 [O]": "1,764.00",
            "TOWER 2 [P]": "98.00",
            "TOWER 3 [Q]": "392.00",
            "TOWER 4 [R]": "2,450.00",
            "[S]": "TRUE",
            "[T]": "686"
          }
        },
        {
          "id": "2 - Main/266-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 200 x 200mm",
          "quantity": 343,
          "unit": "Nr.",
          "rate_aed": 112,
          "amount_aed": 38416,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13709
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "87",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "91",
            "TOTAL QTY [I]": "343",
            "BASEMENTS [M]": "112.00",
            "GF & PODIUM [N]": "3,696.00",
            "TOWER 1 [O]": "2,912.00",
            "TOWER 2 [P]": "9,744.00",
            "TOWER 3 [Q]": "11,760.00",
            "TOWER 4 [R]": "10,192.00",
            "[S]": "TRUE",
            "[T]": "7280"
          }
        },
        {
          "id": "2 - Main/266-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 200mm",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 126,
          "amount_aed": 3780,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13711
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "126.00",
            "GF & PODIUM [N]": "3,276.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "252.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "126.00",
            "[S]": "TRUE",
            "[T]": "126"
          }
        },
        {
          "id": "2 - Main/266-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 250 x 250mm",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 6440,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13713
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280.00",
            "TOWER 1 [O]": "6,020.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "140.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6020"
          }
        },
        {
          "id": "2 - Main/266-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13715
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "140.00",
            "TOWER 1 [O]": "140.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "140.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-140"
          }
        },
        {
          "id": "2 - Main/266-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 250mm",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 154,
          "amount_aed": 2310,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,848.00",
            "TOWER 1 [O]": "154.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "308.00",
            "[S]": "TRUE",
            "[T]": "154"
          }
        },
        {
          "id": "2 - Main/266-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 300 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 504,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "168.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "168.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "168.00",
            "[S]": "TRUE",
            "[T]": "168"
          }
        },
        {
          "id": "2 - Main/266-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 154,
          "amount_aed": 462,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "308.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "154.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 336,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13723
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "168.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "168.00",
            "[S]": "TRUE",
            "[T]": "168"
          }
        },
        {
          "id": "2 - Main/266-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 300mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 728,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "364.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "364.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 350 x 350mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 1568,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "588.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "980.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 168,
          "amount_aed": 336,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "336.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/266-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 250mm",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 2366,
          "amount_state": "number",
          "printed_page": "2/Q/148",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "364.00",
            "TOWER 1 [O]": "546.00",
            "TOWER 2 [P]": "546.00",
            "TOWER 3 [Q]": "364.00",
            "TOWER 4 [R]": "546.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/267",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 27538,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/267-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 300mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 1960,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "784.00",
            "TOWER 1 [O]": "392.00",
            "TOWER 2 [P]": "196.00",
            "TOWER 3 [Q]": "392.00",
            "TOWER 4 [R]": "196.00",
            "[S]": "TRUE",
            "[T]": "-196"
          }
        },
        {
          "id": "2 - Main/267-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "400 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 400 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 224,
          "amount_aed": 672,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "448.00",
            "TOWER 2 [P]": "224.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-448"
          }
        },
        {
          "id": "2 - Main/267-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 400mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "238.00",
            "TOWER 3 [Q]": "476.00",
            "TOWER 4 [R]": "1,666.00",
            "[S]": "TRUE",
            "[T]": "1666"
          }
        },
        {
          "id": "2 - Main/267-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 392,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "196.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "196.00",
            "[S]": "TRUE",
            "[T]": "196"
          }
        },
        {
          "id": "2 - Main/267-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13752
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/267-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 952,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13754
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "476.00",
            "TOWER 1 [O]": "238.00",
            "TOWER 2 [P]": "238.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-238"
          }
        },
        {
          "id": "2 - Main/267-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "450 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 450 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 252,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13756
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "252.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/267-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 196,
          "amount_aed": 196,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13758
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "196.00",
            "[S]": "TRUE",
            "[T]": "196"
          }
        },
        {
          "id": "2 - Main/267-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "210.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/267-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 1008,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "504.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "504.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-504"
          }
        },
        {
          "id": "2 - Main/267-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "500 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 500 x 450mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 266,
          "amount_aed": 1596,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "266.00",
            "TOWER 1 [O]": "532.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "798.00",
            "[S]": "TRUE",
            "[T]": "266"
          }
        },
        {
          "id": "2 - Main/267-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 714,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13766
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "476.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "238.00",
            "[S]": "TRUE",
            "[T]": "238"
          }
        },
        {
          "id": "2 - Main/267-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 350mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 2016,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13768
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "504.00",
            "TOWER 3 [Q]": "252.00",
            "TOWER 4 [R]": "1,260.00",
            "[S]": "TRUE",
            "[T]": "1260"
          }
        },
        {
          "id": "2 - Main/267-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 400mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 266,
          "amount_aed": 2394,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13770
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "266.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "532.00",
            "TOWER 3 [Q]": "1,064.00",
            "TOWER 4 [R]": "532.00",
            "[S]": "TRUE",
            "[T]": "532"
          }
        },
        {
          "id": "2 - Main/267-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 280,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13772
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/267-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 500mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 294,
          "amount_aed": 882,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13774
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "882.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-882"
          }
        },
        {
          "id": "2 - Main/267-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "550 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 550 x 550mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 308,
          "amount_aed": 2464,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13776
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "308.00",
            "TOWER 2 [P]": "1,232.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "924.00",
            "[S]": "TRUE",
            "[T]": "616"
          }
        },
        {
          "id": "2 - Main/267-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 476,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13778
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "238.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "238.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/267-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 252,
          "amount_aed": 504,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13780
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "504.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-504"
          }
        },
        {
          "id": "2 - Main/267-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 350mm",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 266,
          "amount_aed": 3990,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13782
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "11",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "798.00",
            "TOWER 3 [Q]": "2,926.00",
            "TOWER 4 [R]": "266.00",
            "[S]": "TRUE",
            "[T]": "266"
          }
        },
        {
          "id": "2 - Main/267-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 400mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13784
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "560.00",
            "TOWER 2 [P]": "280.00",
            "TOWER 3 [Q]": "560.00",
            "TOWER 4 [R]": "840.00",
            "[S]": "TRUE",
            "[T]": "280"
          }
        },
        {
          "id": "2 - Main/267-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 500mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 308,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "2/Q/149",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13786
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,232.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "308.00",
            "[S]": "TRUE",
            "[T]": "308"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/268",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 25074,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/268-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 550mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 322,
          "amount_aed": 1610,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "322.00",
            "TOWER 3 [Q]": "322.00",
            "TOWER 4 [R]": "966.00",
            "[S]": "TRUE",
            "[T]": "966"
          }
        },
        {
          "id": "2 - Main/268-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "600 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 600 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 1344,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,008.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "336.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 350mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 280,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "560.00",
            "TOWER 4 [R]": "1,120.00",
            "[S]": "TRUE",
            "[T]": "560"
          }
        },
        {
          "id": "2 - Main/268-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 294,
          "amount_aed": 1176,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "882.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "294.00",
            "[S]": "TRUE",
            "[T]": "294"
          }
        },
        {
          "id": "2 - Main/268-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 450mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 308,
          "amount_aed": 924,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "924.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 500mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 322,
          "amount_aed": 966,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "322.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "644.00",
            "[S]": "TRUE",
            "[T]": "644"
          }
        },
        {
          "id": "2 - Main/268-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 550mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 1008,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "336.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "672.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 650 x 600mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 2450,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "350.00",
            "TOWER 3 [Q]": "1,400.00",
            "TOWER 4 [R]": "350.00",
            "[S]": "TRUE",
            "[T]": "350"
          }
        },
        {
          "id": "2 - Main/268-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 700 x 400mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 308,
          "amount_aed": 1848,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "924.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "924.00",
            "[S]": "TRUE",
            "[T]": "924"
          }
        },
        {
          "id": "2 - Main/268-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 700 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 322,
          "amount_aed": 644,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13817
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "644.00",
            "[S]": "TRUE",
            "[T]": "644"
          }
        },
        {
          "id": "2 - Main/268-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 700 x 500mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 1008,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13819
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,008.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 700 x 550mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13821
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 322,
          "amount_aed": 644,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13823
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "322.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "322.00",
            "[S]": "TRUE",
            "[T]": "322"
          }
        },
        {
          "id": "2 - Main/268-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 672,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "672.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "350.00",
            "[S]": "TRUE",
            "[T]": "350"
          }
        },
        {
          "id": "2 - Main/268-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 700mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 406,
          "amount_aed": 812,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13829
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "406.00",
            "TOWER 4 [R]": "406.00",
            "[S]": "TRUE",
            "[T]": "406"
          }
        },
        {
          "id": "2 - Main/268-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 750 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "800 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 800 x 350mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 322,
          "amount_aed": 966,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "644.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "322.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-644"
          }
        },
        {
          "id": "2 - Main/268-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "800 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 800 x 400mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 2016,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "672.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,344.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "800 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 800 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 1750,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,050.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/268-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "800 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 800 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 406,
          "amount_aed": 406,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "406.00",
            "[S]": "TRUE",
            "[T]": "406"
          }
        },
        {
          "id": "2 - Main/268-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/Q/150",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/269",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 26376,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/269-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 364,
          "amount_aed": 1820,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13854
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,820.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 350mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 336,
          "amount_aed": 3696,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13856
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "672.00",
            "TOWER 3 [Q]": "2,352.00",
            "TOWER 4 [R]": "672.00",
            "[S]": "TRUE",
            "[T]": "672"
          }
        },
        {
          "id": "2 - Main/269-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 450mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 364,
          "amount_aed": 1820,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13858
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,820.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "850 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 850 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13860
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-420"
          }
        },
        {
          "id": "2 - Main/269-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "900 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 900 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13862
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "700.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-700"
          }
        },
        {
          "id": "2 - Main/269-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "900 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 900 x 400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 364,
          "amount_aed": 1092,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13864
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "728.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "364.00",
            "[S]": "TRUE",
            "[T]": "364"
          }
        },
        {
          "id": "2 - Main/269-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "900 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 900 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 378,
          "amount_aed": 378,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13866
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "378.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-378"
          }
        },
        {
          "id": "2 - Main/269-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "900 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 900 x 750mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 462,
          "amount_aed": 462,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13868
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "462.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "950 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 950 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 392,
          "amount_aed": 392,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13870
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "392.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "950 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 950 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 448,
          "amount_aed": 448,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13872
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "448.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1000 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1000 x 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 392,
          "amount_aed": 1568,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13874
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,568.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1000 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1000 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13876
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "420.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1000 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1000 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 490,
          "amount_aed": 980,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13878
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "490.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "490.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-490"
          }
        },
        {
          "id": "2 - Main/269-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1000 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1000 x 900mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 532,
          "amount_aed": 532,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13880
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "532.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1050 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1050 x 350mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 392,
          "amount_aed": 2352,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13882
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "392.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1050 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1050 x 500mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 434,
          "amount_aed": 2604,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13884
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,604.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1100 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1100 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 448,
          "amount_aed": 448,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13886
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "448.00",
            "[S]": "TRUE",
            "[T]": "448"
          }
        },
        {
          "id": "2 - Main/269-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1100 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1100 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 476,
          "amount_aed": 476,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13888
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "476.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1150 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1150 x 450mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 448,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13890
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "448.00",
            "TOWER 3 [Q]": "448.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1150 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1150 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 602,
          "amount_aed": 602,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13892
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "602.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/269-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1200 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1200 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 462,
          "amount_aed": 462,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13894
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "462.00",
            "[S]": "TRUE",
            "[T]": "462"
          }
        },
        {
          "id": "2 - Main/269-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1200 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1200 x 500mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 476,
          "amount_aed": 3808,
          "amount_state": "number",
          "printed_page": "2/Q/151",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13896
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,332.00",
            "TOWER 4 [R]": "476.00",
            "[S]": "TRUE",
            "[T]": "476"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/270",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 19482,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/270-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1250 x 1200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1250 x 1200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 686,
          "amount_aed": 686,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "686.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1300 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1300 x 550mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 518,
          "amount_aed": 1036,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,036.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1300 x 1100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1300 x 1100mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 672,
          "amount_aed": 672,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13913
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "672.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1350 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1350 x 450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 504,
          "amount_aed": 504,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "504.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1450 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1450 x 550mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 560,
          "amount_aed": 560,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "560.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1400 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1400 x 900mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 644,
          "amount_aed": 644,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "644.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-644"
          }
        },
        {
          "id": "2 - Main/270-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Volume control damper (VCD)"
          ],
          "own_description": "1500 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Volume control damper (VCD) — 1500 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 560,
          "amount_aed": 560,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 150 x 150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 180,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 200 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 240,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 250 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 300 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 330,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13931
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "550 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 550 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 540,
          "amount_aed": 540,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13933
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "540.00",
            "[S]": "TRUE",
            "[T]": "540"
          }
        },
        {
          "id": "2 - Main/270-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "700 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 700 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 630,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13935
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "630.00",
            "TOWER 4 [R]": "630.00",
            "[S]": "TRUE",
            "[T]": "630"
          }
        },
        {
          "id": "2 - Main/270-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "800 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 800 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 690,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "690.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "1000 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 1000 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13939
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "1200 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 1200 x 800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "1250 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 1250 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13943
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "1400 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 1400 x 1350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1650,
          "amount_aed": 1650,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13945
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,650.00",
            "[S]": "TRUE",
            "[T]": "1650"
          }
        },
        {
          "id": "2 - Main/270-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Non return damper (NRD)"
          ],
          "own_description": "1450 x 1400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Non return damper (NRD) — 1450 x 1400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1710,
          "amount_aed": 1710,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13947
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,710.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/270-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Motorized damper (MD)"
          ],
          "own_description": "1600 x 1550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Motorized damper (MD) — 1600 x 1550mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3780.0000000000005,
          "amount_aed": 3780.0000000000005,
          "amount_state": "number",
          "printed_page": "2/Q/152",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,780.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/271",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 108090,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/271-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1000 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1000 x 1000mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 6800,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1100 x 1100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1100 x 1100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3740.0000000000005,
          "amount_aed": 14960.000000000002,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1200 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1200 x 800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3400,
          "amount_aed": 3400,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1200 x 1150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1200 x 1150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3995,
          "amount_aed": 7990,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1250 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1250 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4250,
          "amount_aed": 4250,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1300 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1300 x 1300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4420,
          "amount_aed": 4420,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4420"
          }
        },
        {
          "id": "2 - Main/271-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1350 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1350 x 1300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4505,
          "amount_aed": 9010,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1400 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1400 x 1350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4675,
          "amount_aed": 4675,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,675.00",
            "[S]": "TRUE",
            "[T]": "4675"
          }
        },
        {
          "id": "2 - Main/271-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1400 x 1400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1400 x 1400mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 4760,
          "amount_aed": 14280,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13982
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-9520"
          }
        },
        {
          "id": "2 - Main/271-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1450 x 1400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1450 x 1400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4845,
          "amount_aed": 4845,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13984
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,845.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1500 x 1450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1500 x 1450mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5015,
          "amount_aed": 5015,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,015.00",
            "[S]": "TRUE",
            "[T]": "5015"
          }
        },
        {
          "id": "2 - Main/271-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1550 x 1500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1550 x 1500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5185,
          "amount_aed": 10370,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,370.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary",
            "Sound attenuator (SAT)"
          ],
          "own_description": "1600 x 1550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Ductwork accessories; including fittings, connections, fixing materials, supports, hangers, sealants, sleeves, fire stopping compound, accessories and all ancillary works as necessary — Sound attenuator (SAT) — 1600 x 1550mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5355,
          "amount_aed": 5355,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,355.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-01; circular",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-01; circular",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13996
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "7",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "1,400.00",
            "TOWER 3 [Q]": "1,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1800"
          }
        },
        {
          "id": "2 - Main/271-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-03; circular",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-03; circular",
          "quantity": 33,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 6600,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 13998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-04; circular",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-04; circular",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/271-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-04; square",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-04; square",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "2/Q/153",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14002
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/272",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 48612,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/272-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-05; circular",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-05; circular",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-05; square",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-05; square",
          "quantity": 167,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 33400,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "38",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "26",
            "TOTAL QTY [I]": "167",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "9,200.00",
            "TOWER 2 [P]": "7,600.00",
            "TOWER 3 [Q]": "10,600.00",
            "TOWER 4 [R]": "5,200.00",
            "[S]": "TRUE",
            "[T]": "-4000"
          }
        },
        {
          "id": "2 - Main/272-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-06; circular",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-06; circular",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary",
            "Extract diffuser"
          ],
          "own_description": "ED-06; square",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Aluminum grilles, diffusers, registers and louvers complete including fixings, plenum box, flexible ducts, built-in VCD, finish as per selection, accessories  and all ancillary works as necessary — Extract diffuser — ED-06; square",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "100 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 100 x 100mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 52,
          "amount_aed": 572,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "572.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "150 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 150 x 100mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 585,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "585.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 150 x 150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 78,
          "amount_aed": 312,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "312.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 200 x 150mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 91,
          "amount_aed": 273,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "273.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 200 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 104,
          "amount_aed": 312,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "312.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 250 x 200mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 117,
          "amount_aed": 351,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14035
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "351.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "300 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 300 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 156,
          "amount_aed": 156,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14037
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "156.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "1000 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 1000 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 520,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14039
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "1200 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 1200 x 800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 520,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14041
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "1250 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 1250 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 650,
          "amount_aed": 650,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14043
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "100 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 100 x 100mm",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 52,
          "amount_aed": 884,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14047
          },
          "extra_columns": {
            "Basement [C]": "10",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "520.00",
            "GF & PODIUM [N]": "364.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "150 x 100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 150 x 100mm",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 2210,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14049
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "455.00",
            "GF & PODIUM [N]": "1,755.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 150 x 150mm",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 78,
          "amount_aed": 2418,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14051
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "624.00",
            "GF & PODIUM [N]": "1,794.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "200 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 200 x 150mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 91,
          "amount_aed": 1092,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14053
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "91.00",
            "GF & PODIUM [N]": "1,001.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 200 x 200mm",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 104,
          "amount_aed": 2184,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,184.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/272-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 250 x 200mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 117,
          "amount_aed": 1053,
          "amount_state": "number",
          "printed_page": "2/Q/154",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,053.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/273",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 5595,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/273-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 250 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 260,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14070
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "300 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 300 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 130,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14072
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 300 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 143,
          "amount_aed": 143,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14074
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "143.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "350 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 350 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 169,
          "amount_aed": 169,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14076
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "169.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 350 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 182,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14078
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "182.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "400 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 400 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 169,
          "amount_aed": 169,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14080
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "169.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 400 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 182,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14082
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "182.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fresh air grille; including wire mesh"
          ],
          "own_description": "450 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fresh air grille; including wire mesh — 450 x 250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 182,
          "amount_aed": 182,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14084
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "182.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "550mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 550mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 182.00000000000003,
          "amount_aed": 182.00000000000003,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14088
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "182.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-182"
          }
        },
        {
          "id": "2 - Main/273-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "650mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 650mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 208,
          "amount_aed": 208,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14090
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "208.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "700mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 700mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 221,
          "amount_aed": 221,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14092
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "221.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-221"
          }
        },
        {
          "id": "2 - Main/273-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "850mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 850mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14094
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "260.00",
            "TOWER 3 [Q]": "260.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "1200mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 1200mm long",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 350.99999999999994,
          "amount_aed": 1052.9999999999998,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14096
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "351.00",
            "TOWER 2 [P]": "351.00",
            "TOWER 3 [Q]": "351.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-351"
          }
        },
        {
          "id": "2 - Main/273-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air grille; including wire mesh"
          ],
          "own_description": "1270mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air grille; including wire mesh — 1270mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 369,
          "amount_aed": 369,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14098
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "369.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "General extract air grille; including wire mesh"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — General extract air grille; including wire mesh — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 117,
          "amount_aed": 117,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14102
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "117.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "General extract air grille; including wire mesh"
          ],
          "own_description": "300 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — General extract air grille; including wire mesh — 300 x 250mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 143,
          "amount_aed": 1144,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14104
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,144.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "SWPED exhaust air grille; including wire mesh"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — SWPED exhaust air grille; including wire mesh — 150 x 150mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 78,
          "amount_aed": 156,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14108
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "78.00",
            "GF & PODIUM [N]": "78.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/273-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "SWPED exhaust air grille; including wire mesh"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — SWPED exhaust air grille; including wire mesh — 200 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 104,
          "amount_aed": 208,
          "amount_state": "number",
          "printed_page": "2/Q/155",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14110
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "104.00",
            "GF & PODIUM [N]": "104.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/274",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 14000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/274-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Sewage holding plant room fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-GF-SWPEF; axial inline type, air flow of 95l/s, external static pressure at 200Pa and power rating of 0.14kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Sewage holding plant room fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-GF-SWPEF; axial inline type, air flow of 95l/s, external static pressure at 200Pa and power rating of 0.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/156",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/274-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Sewage holding plant room fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-SWPEF; axial inline type, air flow of 30l/s, external static pressure at 200Pa and power rating of 0.04kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Sewage holding plant room fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-SWPEF; axial inline type, air flow of 30l/s, external static pressure at 200Pa and power rating of 0.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/Q/156",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/274-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Chemical room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-02F-CEF; axial inline type, air flow of 150l/s, external static pressure at 250Pa and power rating of 0.22kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Chemical room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-02F-CEF; axial inline type, air flow of 150l/s, external static pressure at 250Pa and power rating of 0.22kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/156",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14136
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/274-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Swimming pool plant room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-02F-SPEF; axial inline type, air flow of 165l/s, external static pressure at 250Pa and power rating of 0.24kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Swimming pool plant room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-02F-SPEF; axial inline type, air flow of 165l/s, external static pressure at 250Pa and power rating of 0.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/156",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14140
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/274-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Swimming pool plant room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-02F-SPEF; axial inline type, air flow of 295l/s, external static pressure at 250Pa and power rating of 0.43kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Swimming pool plant room extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-02F-SPEF; axial inline type, air flow of 295l/s, external static pressure at 250Pa and power rating of 0.43kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/156",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14142
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/275",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 40000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/275-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-29F-GEF; axial inline type, air flow of 930l/s, external static pressure at 350Pa and power rating of 1.34kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-29F-GEF; axial inline type, air flow of 930l/s, external static pressure at 350Pa and power rating of 1.34kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14158
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5000"
          }
        },
        {
          "id": "2 - Main/275-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-51F-GEF; axial inline type, air flow of 1,245l/s, external static pressure at 350Pa and power rating of 1.80kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-51F-GEF; axial inline type, air flow of 1,245l/s, external static pressure at 350Pa and power rating of 1.80kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14160
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5000"
          }
        },
        {
          "id": "2 - Main/275-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-29F-GEF; axial inline type, air flow of 1,105l/s, external static pressure at 350Pa and power rating of 1.60kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-29F-GEF; axial inline type, air flow of 1,105l/s, external static pressure at 350Pa and power rating of 1.60kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14162
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/275-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-59F-GEF; axial inline type, air flow of 1,540l/s, external static pressure at 350Pa and power rating of 2.22kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-59F-GEF; axial inline type, air flow of 1,540l/s, external static pressure at 350Pa and power rating of 2.22kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14164
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/275-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-29F-GEF; axial inline type, air flow of 955l/s, external static pressure at 350Pa and power rating of 1.38kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-29F-GEF; axial inline type, air flow of 955l/s, external static pressure at 350Pa and power rating of 1.38kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14166
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/275-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-57F-GEF; axial inline type, air flow of 1,360l/s, external static pressure at 350Pa and power rating of 1.96kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-57F-GEF; axial inline type, air flow of 1,360l/s, external static pressure at 350Pa and power rating of 1.96kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14168
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/275-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-29F-GEF;  axial inline type, air flow of 1,010l/s, external static pressure at 350Pa and power rating of 1.46kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-29F-GEF;  axial inline type, air flow of 1,010l/s, external static pressure at 350Pa and power rating of 1.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14170
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE",
            "[T]": "5000"
          }
        },
        {
          "id": "2 - Main/275-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-55F-GEF;  axial inline type, air flow of 1,385l/s, external static pressure at 350Pa and power rating of 2.00kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Garbage extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-55F-GEF;  axial inline type, air flow of 1,385l/s, external static pressure at 350Pa and power rating of 2.00kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/157",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14172
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE",
            "[T]": "5000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/276",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 12799020,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/276-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Car park exhaust duct (CPED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Car park exhaust duct (CPED)",
          "quantity": 13848,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 4431360,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14194
          },
          "extra_columns": {
            "Basement [C]": "11,792",
            "GF & Podium [D]": "2,056",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13,848",
            "BASEMENTS [M]": "3,773,440.00",
            "GF & PODIUM [N]": "657,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Car park make-up duct (CPMD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Car park make-up duct (CPMD)",
          "quantity": 7264,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 2324480,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14196
          },
          "extra_columns": {
            "Basement [C]": "5,945",
            "GF & Podium [D]": "1,319",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7,264",
            "BASEMENTS [M]": "1,902,400.00",
            "GF & PODIUM [N]": "422,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Car park smoke exhaust duct (CSED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Car park smoke exhaust duct (CSED)",
          "quantity": 10026,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 3208320,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14198
          },
          "extra_columns": {
            "Basement [C]": "6,879",
            "GF & Podium [D]": "3,147",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10,026",
            "BASEMENTS [M]": "2,201,280.00",
            "GF & PODIUM [N]": "1,007,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire pump exhaust duct (FPED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Fire pump exhaust duct (FPED)",
          "quantity": 350,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 112000,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14200
          },
          "extra_columns": {
            "Basement [C]": "53",
            "GF & Podium [D]": "129",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "350",
            "BASEMENTS [M]": "16,960.00",
            "GF & PODIUM [N]": "41,280.00",
            "TOWER 1 [O]": "18,560.00",
            "TOWER 2 [P]": "35,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-18560"
          }
        },
        {
          "id": "2 - Main/276-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire pump exhaust duct (FPMD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Fire pump exhaust duct (FPMD)",
          "quantity": 293,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 93760,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14202
          },
          "extra_columns": {
            "Basement [C]": "45",
            "GF & Podium [D]": "191",
            "Tower 1 [E]": "21",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "293",
            "BASEMENTS [M]": "14,400.00",
            "GF & PODIUM [N]": "61,120.00",
            "TOWER 1 [O]": "6,720.00",
            "TOWER 2 [P]": "5,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,760.00",
            "[S]": "TRUE",
            "[T]": "-960"
          }
        },
        {
          "id": "2 - Main/276-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Make-up air duct (MAD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Make-up air duct (MAD)",
          "quantity": 3324,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 1063680,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14204
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "798",
            "Tower 2 [F]": "903",
            "Tower 3 [G]": "678",
            "Tower 4 [H]": "908",
            "TOTAL QTY [I]": "3,324",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,840.00",
            "TOWER 1 [O]": "255,360.00",
            "TOWER 2 [P]": "288,960.00",
            "TOWER 3 [Q]": "216,960.00",
            "TOWER 4 [R]": "290,560.00",
            "[S]": "TRUE",
            "[T]": "35200"
          }
        },
        {
          "id": "2 - Main/276-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Smoke extract duct (SED)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Smoke extract duct (SED)",
          "quantity": 4026,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 1288320,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14206
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "47",
            "Tower 1 [E]": "904",
            "Tower 2 [F]": "1,056",
            "Tower 3 [G]": "1,013",
            "Tower 4 [H]": "1,006",
            "TOTAL QTY [I]": "4,026",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,040.00",
            "TOWER 1 [O]": "289,280.00",
            "TOWER 2 [P]": "337,920.00",
            "TOWER 3 [Q]": "324,160.00",
            "TOWER 4 [R]": "321,920.00",
            "[S]": "TRUE",
            "[T]": "32640"
          }
        },
        {
          "id": "2 - Main/276-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke installation system",
            "Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary"
          ],
          "own_description": "Stairwell pressurization duct (SPD)",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke installation system — Fire resistance galvanized sheet metal, including supports, galvanized threaded rod, lock nuts and washers, expansion anchor, galvanized hangers and brackets, complete with fittings, non-combustible assembly, accessories and all ancillary works as necessary — Stairwell pressurization duct (SPD)",
          "quantity": 802,
          "unit": "m2",
          "rate_aed": 320,
          "amount_aed": 256640,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14208
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "487",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "90",
            "Tower 4 [H]": "49",
            "TOTAL QTY [I]": "802",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "155,840.00",
            "TOWER 1 [O]": "29,120.00",
            "TOWER 2 [P]": "27,200.00",
            "TOWER 3 [Q]": "28,800.00",
            "TOWER 4 [R]": "15,680.00",
            "[S]": "TRUE",
            "[T]": "-13440"
          }
        },
        {
          "id": "2 - Main/276-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire damper (FD)"
          ],
          "own_description": "1050 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire damper (FD) — 1050 x 650mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 420,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 400 x 300mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 840,
          "amount_aed": 6720,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,680.00",
            "TOWER 2 [P]": "1,680.00",
            "TOWER 3 [Q]": "1,680.00",
            "TOWER 4 [R]": "1,680.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "400 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 400 x 350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-900"
          }
        },
        {
          "id": "2 - Main/276-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "450 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 450 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14220
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/276-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "450 x 400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 450 x 400mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1020,
          "amount_aed": 6120,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,020.00",
            "TOWER 2 [P]": "2,040.00",
            "TOWER 3 [Q]": "1,020.00",
            "TOWER 4 [R]": "2,040.00",
            "[S]": "TRUE",
            "[T]": "1020"
          }
        },
        {
          "id": "2 - Main/276-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "550 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 550 x 500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,260.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1260"
          }
        },
        {
          "id": "2 - Main/276-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "600 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 600 x 550mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1380,
          "amount_aed": 4140,
          "amount_state": "number",
          "printed_page": "2/Q/158",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,380.00",
            "TOWER 3 [Q]": "1,380.00",
            "TOWER 4 [R]": "1,380.00",
            "[S]": "TRUE",
            "[T]": "1380"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/277",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 478450,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/277-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "750 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 750 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1620,
          "amount_aed": 6480,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14241
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "1,620.00",
            "GF & PODIUM [N]": "4,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "750 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 750 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1740,
          "amount_aed": 1740,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,740.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "800 x 450mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 800 x 450mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "800 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 800 x 600mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1680,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3360"
          }
        },
        {
          "id": "2 - Main/277-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "800 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 800 x 650mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1740,
          "amount_aed": 3480,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,480.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "800 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 800 x 700mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1800,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "7,200.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "800 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 800 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1860,
          "amount_aed": 3720,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,720.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3720"
          }
        },
        {
          "id": "2 - Main/277-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "1050 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 1050 x 650mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2040,
          "amount_aed": 8160,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "1150 x 1150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 1150 x 1150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2760,
          "amount_aed": 11040,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14257
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "5,520.00",
            "GF & PODIUM [N]": "5,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "1250 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 1250 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2700,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized damper (MD)"
          ],
          "own_description": "1250 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized damper (MD) — 1250 x 1250mm",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 39000,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14261
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "6,000.00",
            "GF & PODIUM [N]": "33,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 200 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 880,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-880"
          }
        },
        {
          "id": "2 - Main/277-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 400 x 300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,540.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "2200 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 2200 x 1350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7810.000000000001,
          "amount_aed": 7810.000000000001,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,810.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "2300 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 2300 x 1300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7919.999999999999,
          "amount_aed": 15839.999999999998,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "2500 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 2500 x 1300mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 8360,
          "amount_aed": 41800,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14273
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "41,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Motorized smoke and fire damper (MSFD)"
          ],
          "own_description": "2500 x 1500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Motorized smoke and fire damper (MSFD) — 2500 x 1500mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 8800,
          "amount_aed": 52800,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14275
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "52,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/277-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 150 x 150mm",
          "quantity": 391,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 70380,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "89",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "110",
            "TOTAL QTY [I]": "391",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,020.00",
            "TOWER 2 [P]": "16,200.00",
            "TOWER 3 [Q]": "18,360.00",
            "TOWER 4 [R]": "19,800.00",
            "[S]": "TRUE",
            "[T]": "3780"
          }
        },
        {
          "id": "2 - Main/277-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "200 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 200 x 200mm",
          "quantity": 738,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 177120,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "169",
            "Tower 2 [F]": "187",
            "Tower 3 [G]": "210",
            "Tower 4 [H]": "168",
            "TOTAL QTY [I]": "738",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "40,560.00",
            "TOWER 2 [P]": "44,880.00",
            "TOWER 3 [Q]": "50,400.00",
            "TOWER 4 [R]": "40,320.00",
            "[S]": "TRUE",
            "[T]": "-240"
          }
        },
        {
          "id": "2 - Main/277-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "250 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 250 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/159",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/278",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 108122,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/278-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 300 x 150mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 350 x 350mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14298
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 400 x 200mm",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 360,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14300
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "400 x 250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 400 x 250mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 390,
          "amount_aed": 780,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14302
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "780.00",
            "[S]": "TRUE",
            "[T]": "780"
          }
        },
        {
          "id": "2 - Main/278-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "400 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 400 x 300mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "420.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "400 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 400 x 350mm",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14306
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "750 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 750 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 870,
          "amount_aed": 870,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14308
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "870.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "1500 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 1500 x 900mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1440,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14310
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "5,760.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "1800 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 1800 x 900mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1620,
          "amount_aed": 8100,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14312
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "8,100.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2050 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2050 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1980,
          "amount_aed": 1980,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14314
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2100 x 1400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2100 x 1400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14316
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2200 x 1150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2200 x 1150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2010,
          "amount_aed": 2010,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14318
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2200 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2200 x 1350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2130,
          "amount_aed": 2130,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14320
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2300 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2300 x 1300mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2160,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14322
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2500 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2500 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14324
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2500 x 1050mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2500 x 1050mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2130,
          "amount_aed": 2130,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2500 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2500 x 1300mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 2280,
          "amount_aed": 15960,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14328
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "15,960.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke motorized damper (SMD)"
          ],
          "own_description": "2500 x 1500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke motorized damper (SMD) — 2500 x 1500mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2400,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14330
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "14,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "650 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 650 x 650mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 364,
          "amount_aed": 728,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14334
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "728.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 700 x 350mm",
          "quantity": 74,
          "unit": "Nr.",
          "rate_aed": 294,
          "amount_aed": 21756,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,756.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/278-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "700 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 700 x 650mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 378,
          "amount_aed": 4158,
          "amount_state": "number",
          "printed_page": "2/Q/160",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14338
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "4,158.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/279",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 131642,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/279-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 750 x 350mm",
          "quantity": 298,
          "unit": "Nr.",
          "rate_aed": 308,
          "amount_aed": 91784,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14351
          },
          "extra_columns": {
            "Basement [C]": "298",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "298",
            "BASEMENTS [M]": "91,784.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "750 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 750 x 700mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 406,
          "amount_aed": 4466,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14353
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "4,466.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1100 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1100 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 490,
          "amount_aed": 490,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14355
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "490.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1150 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1150 x 650mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 504,
          "amount_aed": 1008,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14357
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,008.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1250 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1250 x 700mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 546,
          "amount_aed": 1092,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14359
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,092.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1350 x 750mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1350 x 750mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 588,
          "amount_aed": 588,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14361
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "588.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1450 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1450 x 500mm",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 546,
          "amount_aed": 10374,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14363
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,374.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1450 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1450 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 602,
          "amount_aed": 602,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14365
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "602.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1500 x 500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1500 x 500mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 560,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14367
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1500 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1500 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 616,
          "amount_aed": 616,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14369
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "616.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1500 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1500 x 900mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 672,
          "amount_aed": 2016,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14371
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "2,016.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1650 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1650 x 700mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 658,
          "amount_aed": 1316,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14373
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,316.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1800 x 900mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1800 x 900mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 756,
          "amount_aed": 3780,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14375
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "3,780.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1850 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1850 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 714,
          "amount_aed": 714,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14377
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "714.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "1900 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 1900 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 714,
          "amount_aed": 714,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "714.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2050 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2050 x 800mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 798,
          "amount_aed": 2394,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14381
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "2,394.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2050 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2050 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 924,
          "amount_aed": 924,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "924.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2150 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2150 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 882,
          "amount_aed": 882,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14385
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "882.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2100 x 1400mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2100 x 1400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 980,
          "amount_aed": 980,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2200 x 1150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2200 x 1150mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 938,
          "amount_aed": 938,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "938.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-W",
          "item_code": "W",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2200 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2200 x 1350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 994,
          "amount_aed": 1988,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,988.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/279-X",
          "item_code": "X",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2300 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2300 x 800mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 868,
          "amount_aed": 1736,
          "amount_state": "number",
          "printed_page": "2/Q/161",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14393
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,736.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/280",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 147756,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/280-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2300 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2300 x 1300mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1008,
          "amount_aed": 3024,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14406
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,024.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2350 x 850mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2350 x 850mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 896,
          "amount_aed": 3584,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14408
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "3,584.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2400 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2400 x 1250mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1022,
          "amount_aed": 1022,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14410
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,022.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 700mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 896,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14412
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "896.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 800mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 924,
          "amount_aed": 1848,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14414
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "1,848.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1050mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1050mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 994,
          "amount_aed": 994,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14416
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "994.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 980,
          "amount_aed": 980,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14418
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1100mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1100mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1008,
          "amount_aed": 4032,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14420
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "4,032.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1300mm",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1064,
          "amount_aed": 17024,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14422
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "17,024.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1500mm",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1120,
          "amount_aed": 15680,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14424
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "15,680.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "2500 x 1600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 2500 x 1600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1148,
          "amount_aed": 1148,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14426
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "1,148.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "3200 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 3200 x 800mm",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 1120,
          "amount_aed": 10080,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "3400 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 3400 x 800mm",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 1176,
          "amount_aed": 21168,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14430
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "21,168.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Volume control damper (VCD)"
          ],
          "own_description": "4000 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Volume control damper (VCD) — 4000 x 800mm",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1344,
          "amount_aed": 18816,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14432
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "18,816.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Non return damper (NRD)"
          ],
          "own_description": "600 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Non return damper (NRD) — 600 x 550mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 690,
          "amount_aed": 690,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "690.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Non return damper (NRD)"
          ],
          "own_description": "700 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Non return damper (NRD) — 700 x 350mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 629.9999999999999,
          "amount_aed": 1259.9999999999998,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "630.00",
            "TOWER 4 [R]": "630.00",
            "[S]": "TRUE",
            "[T]": "630"
          }
        },
        {
          "id": "2 - Main/280-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Non return damper (NRD)"
          ],
          "own_description": "1400 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Non return damper (NRD) — 1400 x 1350mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1650,
          "amount_aed": 1650,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,650.00",
            "[S]": "TRUE",
            "[T]": "1650"
          }
        },
        {
          "id": "2 - Main/280-T",
          "item_code": "T",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Sound attenuator (SAT)"
          ],
          "own_description": "750 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Sound attenuator (SAT) — 750 x 700mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2465,
          "amount_aed": 4930,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-U",
          "item_code": "U",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Sound attenuator (SAT)"
          ],
          "own_description": "1150 x 1150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Sound attenuator (SAT) — 1150 x 1150mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 3909.9999999999995,
          "amount_aed": 31279.999999999996,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14446
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "15,640.00",
            "GF & PODIUM [N]": "15,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/280-V",
          "item_code": "V",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Sound attenuator (SAT)"
          ],
          "own_description": "1250 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Sound attenuator (SAT) — 1250 x 1000mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3825,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/Q/162",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/281",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 502480,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/281-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Sound attenuator (SAT)"
          ],
          "own_description": "1250 x 1250mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Sound attenuator (SAT) — 1250 x 1250mm",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 4250,
          "amount_aed": 110500,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14461
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "17,000.00",
            "GF & PODIUM [N]": "93,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Sound attenuator (SAT)"
          ],
          "own_description": "1400 x 1350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Sound attenuator (SAT) — 1400 x 1350mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 4675,
          "amount_aed": 56100,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Supply register"
          ],
          "own_description": "1300 x 1050",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Supply register — 1300 x 1050",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 705,
          "amount_aed": 2820,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park exhaust grille (CPEG); egg crate grille"
          ],
          "own_description": "250 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park exhaust grille (CPEG); egg crate grille — 250 x 200mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park exhaust grille (CPEG); egg crate grille"
          ],
          "own_description": "750 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park exhaust grille (CPEG); egg crate grille — 750 x 350mm",
          "quantity": 409,
          "unit": "Nr.",
          "rate_aed": 440.00000000000006,
          "amount_aed": 179960.00000000003,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14473
          },
          "extra_columns": {
            "Basement [C]": "332",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "409",
            "BASEMENTS [M]": "146,080.00",
            "GF & PODIUM [N]": "33,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park smoke exhaust grille (CSEG); egg crate grille"
          ],
          "own_description": "2100 x 550mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park smoke exhaust grille (CSEG); egg crate grille — 2100 x 550mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1060.0000000000002,
          "amount_aed": 6360.000000000002,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park smoke exhaust grille (CSEG); egg crate grille"
          ],
          "own_description": "3200 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park smoke exhaust grille (CSEG); egg crate grille — 3200 x 800mm",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1600,
          "amount_aed": 17600,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park smoke exhaust grille (CSEG); egg crate grille"
          ],
          "own_description": "3400 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park smoke exhaust grille (CSEG); egg crate grille — 3400 x 800mm",
          "quantity": 23,
          "unit": "Nr.",
          "rate_aed": 1680,
          "amount_aed": 38640,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14481
          },
          "extra_columns": {
            "Basement [C]": "23",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "38,640.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park smoke exhaust grille (CSEG); egg crate grille"
          ],
          "own_description": "4000 x 800mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park smoke exhaust grille (CSEG); egg crate grille — 4000 x 800mm",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 1920,
          "amount_aed": 46080,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14483
          },
          "extra_columns": {
            "Basement [C]": "24",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "46,080.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park make-up grille (CPMG); 3 sides, egg crate grille"
          ],
          "own_description": "1950 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park make-up grille (CPMG); 3 sides, egg crate grille — 1950 x 650mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1040,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park make-up grille (CPMG); 3 sides, egg crate grille"
          ],
          "own_description": "2100 x 700mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park make-up grille (CPMG); 3 sides, egg crate grille — 2100 x 700mm",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 1120,
          "amount_aed": 38080,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14489
          },
          "extra_columns": {
            "Basement [C]": "34",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "38,080.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park make-up air duct (CPMD) grille; including wire mesh"
          ],
          "own_description": "1250 x 1000mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park make-up air duct (CPMD) grille; including wire mesh — 1250 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 900,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park make-up air duct (CPMD) grille; including wire mesh"
          ],
          "own_description": "2350 x 1500mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park make-up air duct (CPMD) grille; including wire mesh — 2350 x 1500mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/281-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up air duct (FPMD) grille; including wire mesh"
          ],
          "own_description": "750 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up air duct (FPMD) grille; including wire mesh — 750 x 600mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 405,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/Q/163",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14499
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "405.00",
            "GF & PODIUM [N]": "1,215.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/282",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 136816,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/282-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump exhaust duct (FPED) grille; including wire mesh"
          ],
          "own_description": "750 x 600mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump exhaust duct (FPED) grille; including wire mesh — 750 x 600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 405,
          "amount_aed": 405,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14514
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "405.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/282-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "400 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 400 x 350mm",
          "quantity": 100,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 22500,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "25",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "5,625.00",
            "TOWER 2 [P]": "4,500.00",
            "TOWER 3 [Q]": "11,475.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5625"
          }
        },
        {
          "id": "2 - Main/282-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 350 x 150mm",
          "quantity": 45,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 6750,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3000"
          }
        },
        {
          "id": "2 - Main/282-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 350 x 350mm",
          "quantity": 99,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 20790,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "95",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "19,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-19950"
          }
        },
        {
          "id": "2 - Main/282-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "400 x 200mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 400 x 200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 180.00000000000003,
          "amount_aed": 360.00000000000006,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "360"
          }
        },
        {
          "id": "2 - Main/282-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "400 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 400 x 350mm",
          "quantity": 320,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 72000,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "95",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "320",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "21,375.00",
            "TOWER 3 [Q]": "23,625.00",
            "TOWER 4 [R]": "22,500.00",
            "[S]": "TRUE",
            "[T]": "22500"
          }
        },
        {
          "id": "2 - Main/282-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "400mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 400mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 150,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-150"
          }
        },
        {
          "id": "2 - Main/282-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 500mm long",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 188,
          "amount_aed": 564,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "188.00",
            "TOWER 3 [Q]": "188.00",
            "TOWER 4 [R]": "188.00",
            "[S]": "TRUE",
            "[T]": "188"
          }
        },
        {
          "id": "2 - Main/282-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "650mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 650mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 244,
          "amount_aed": 488,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "244.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "244.00",
            "[S]": "TRUE",
            "[T]": "244"
          }
        },
        {
          "id": "2 - Main/282-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "800mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 800mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14534
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-600"
          }
        },
        {
          "id": "2 - Main/282-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "850mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 850mm long",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 319,
          "amount_aed": 1914,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14536
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "957.00",
            "TOWER 3 [Q]": "957.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/282-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "1200mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 1200mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14538
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "450.00",
            "[S]": "TRUE",
            "[T]": "450"
          }
        },
        {
          "id": "2 - Main/282-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "3000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 3000mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1125,
          "amount_aed": 1125,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14540
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,125.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/282-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "3500mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 3500mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1313,
          "amount_aed": 2626,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14542
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,313.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,313.00",
            "[S]": "TRUE",
            "[T]": "1313"
          }
        },
        {
          "id": "2 - Main/282-Q",
          "item_code": "Q",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "4000mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 4000mm long",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14544
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE",
            "[T]": "1500"
          }
        },
        {
          "id": "2 - Main/282-R",
          "item_code": "R",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "4100mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 4100mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1538,
          "amount_aed": 1538,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,538.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1538"
          }
        },
        {
          "id": "2 - Main/282-S",
          "item_code": "S",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make up-air duct (MAD) grille; including wire mesh"
          ],
          "own_description": "4150mm long",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make up-air duct (MAD) grille; including wire mesh — 4150mm long",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1556,
          "amount_aed": 1556,
          "amount_state": "number",
          "printed_page": "2/Q/164",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,556.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1556"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/283",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 758870,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/283-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke extract duct (SED) grille; including wire mesh"
          ],
          "own_description": "150 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke extract duct (SED) grille; including wire mesh — 150 x 150mm",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 2250,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "25",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2250"
          }
        },
        {
          "id": "2 - Main/283-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke extract duct (SED) grille; including wire mesh"
          ],
          "own_description": "300 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke extract duct (SED) grille; including wire mesh — 300 x 150mm",
          "quantity": 98,
          "unit": "Nr.",
          "rate_aed": 135,
          "amount_aed": 13230,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "540.00",
            "TOWER 1 [O]": "135.00",
            "TOWER 2 [P]": "2,700.00",
            "TOWER 3 [Q]": "6,885.00",
            "TOWER 4 [R]": "2,970.00",
            "[S]": "TRUE",
            "[T]": "2835"
          }
        },
        {
          "id": "2 - Main/283-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke extract duct (SED) grille; including wire mesh"
          ],
          "own_description": "350 x 150mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke extract duct (SED) grille; including wire mesh — 350 x 150mm",
          "quantity": 44,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 6600,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,850.00",
            "TOWER 2 [P]": "3,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2850"
          }
        },
        {
          "id": "2 - Main/283-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke extract duct (SED) grille; including wire mesh"
          ],
          "own_description": "350 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke extract duct (SED) grille; including wire mesh — 350 x 350mm",
          "quantity": 99,
          "unit": "Nr.",
          "rate_aed": 210,
          "amount_aed": 20790,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "95",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "840.00",
            "TOWER 1 [O]": "19,950.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-19950"
          }
        },
        {
          "id": "2 - Main/283-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Smoke extract duct (SED) grille; including wire mesh"
          ],
          "own_description": "400 x 350mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Smoke extract duct (SED) grille; including wire mesh — 400 x 350mm",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 225,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stairwell pressurization duct (SPD) grille; including wire mesh"
          ],
          "own_description": "1050 x 650mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stairwell pressurization duct (SPD) grille; including wire mesh — 1050 x 650mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 850.0000000000001,
          "amount_aed": 3400.0000000000005,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Carbon monoxide sensor; including wirings, fixings, complete"
          ],
          "own_description": "CO sensor",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Carbon monoxide sensor; including wirings, fixings, complete — CO sensor",
          "quantity": 197,
          "unit": "Nr.",
          "rate_aed": 2300,
          "amount_aed": 453100,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14581
          },
          "extra_columns": {
            "Basement [C]": "137",
            "GF & Podium [D]": "60",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "315,100.00",
            "GF & PODIUM [N]": "138,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-GF-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-GF-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-GF-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-GF-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-GF-CPMAF-03; air flow 4,400l/s, ESP at 1000Pa and power rating of 10kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-GF-CPMAF-03; air flow 4,400l/s, ESP at 1000Pa and power rating of 10kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 23000,
          "amount_aed": 23000,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-GF-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-GF-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/283-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-BF1-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-BF1-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/165",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14595
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "58,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/284",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1259500,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/284-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-BF1-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-BF1-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14608
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "58,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-BF1-CPMAF-03; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-BF1-CPMAF-03; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14610
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "58,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-BF1-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-BF1-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14612
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "58,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-CPMAF-01; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14614
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-CPMAF-02; air flow 11,055l/s, ESP at 1000Pa and power rating of 25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14616
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-CPMAF-03; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-CPMAF-03; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14618
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-CPMAF-04; air flow 13,200l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14620
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary",
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-CPMAF-05; air flow 10,440l/s, ESP at 1000Pa and power rating of 23kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Equipments; including vibration isolators, fixing materials, supports, brackets, accessories and all ancillary works as necessary — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-CPMAF-05; air flow 10,440l/s, ESP at 1000Pa and power rating of 23kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 58000,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14622
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-GF-JF-01 to 07; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-GF-JF-01 to 07; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 129500,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14626
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "129,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-GF-JF-01 to 08; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-GF-JF-01 to 08; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 148000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14628
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "148,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-JF-01 to 08; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-JF-01 to 08; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 148000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14630
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "148,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-P1-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-P1-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 185000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14632
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "185,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/284-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P1-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P1-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 185000,
          "amount_state": "number",
          "printed_page": "2/Q/166",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14634
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "185,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/285",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1288000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/285-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P1-JF-01 to 09; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P1-JF-01 to 09; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 166500,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14647
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "166,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-P2-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-P2-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 185000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14649
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "185,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-JF-01 to 10; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 185000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14651
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "185,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P2-JF-01 to 09; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Jet fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P2-JF-01 to 09; air flow 2250/1070l/s, ESP at 100/21Pa and power rating of 2.2kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 18500,
          "amount_aed": 166500,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14653
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "166,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14657
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14659
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14661
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14665
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14669
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14671
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/285-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P2-CPEF-01; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/167",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14673
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/286",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 291000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/286-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P2-CPEF-02; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P2-CPEF-03; air flow 13,000l/s, ESP at 1000Pa and power rating of 29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Car park extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-P2-CPEF-04; air flow 15,600l/s, ESP at 1000Pa and power rating of 35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14690
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-MAF; air flow 1100l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-MAF; air flow 1100l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14694
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12000"
          }
        },
        {
          "id": "2 - Main/286-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-51F-MAF; air flow 870l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-51F-MAF; air flow 870l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14696
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12000"
          }
        },
        {
          "id": "2 - Main/286-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-MAF; air flow 1215l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-MAF; air flow 1215l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14698
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-59F-MAF; air flow 1150l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-59F-MAF; air flow 1150l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14700
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-MAF; air flow 1210l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-MAF; air flow 1210l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-57F-MAF; air flow 1115l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-57F-MAF; air flow 1115l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14704
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/286-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-MAF; air flow 1215l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-MAF; air flow 1215l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14706
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,000.00",
            "[S]": "TRUE",
            "[T]": "12000"
          }
        },
        {
          "id": "2 - Main/286-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-55F-MAF; air flow 1060l/s, ESP at 500Pa and power rating of 2kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Make-up air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-55F-MAF; air flow 1060l/s, ESP at 500Pa and power rating of 2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/Q/168",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14708
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,000.00",
            "[S]": "TRUE",
            "[T]": "12000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/287",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 207000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/287-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-SEF-01; air flow 680l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-SEF-01; air flow 680l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-9000"
          }
        },
        {
          "id": "2 - Main/287-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-SEF-02; air flow 565l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-SEF-02; air flow 565l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-9000"
          }
        },
        {
          "id": "2 - Main/287-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-51F-SEF; air flow 2240l/s, ESP at 500Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-51F-SEF; air flow 2240l/s, ESP at 500Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-25000"
          }
        },
        {
          "id": "2 - Main/287-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-SEF-01; air flow 745l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-SEF-01; air flow 745l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-SEF-02; air flow 625l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-SEF-02; air flow 625l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-59F-SEF; air flow 2665l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-59F-SEF; air flow 2665l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "25,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-SEF-01; air flow 740l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-SEF-01; air flow 740l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-SEF-02; air flow 625/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-SEF-02; air flow 625/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14739
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-57F-SEF; air flow 2630l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-57F-SEF; air flow 2630l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14741
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "25,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/287-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-SEF-01; air flow 745l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-SEF-01; air flow 745l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14743
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,000.00",
            "[S]": "TRUE",
            "[T]": "9000"
          }
        },
        {
          "id": "2 - Main/287-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-SEF-02; air flow 625l/s, ESP at 500Pa and power rating of 1kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-SEF-02; air flow 625l/s, ESP at 500Pa and power rating of 1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14745
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,000.00",
            "[S]": "TRUE",
            "[T]": "9000"
          }
        },
        {
          "id": "2 - Main/287-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-55F-SEF; air flow 2575l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Extract air fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-55F-SEF; air flow 2575l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14747
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "25,000.00",
            "[S]": "TRUE",
            "[T]": "25000"
          }
        },
        {
          "id": "2 - Main/287-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-SPF-01; air flow 5450l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-SPF-01; air flow 5450l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/169",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/288",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 490000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/288-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-SPF-02; air flow 5450l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-SPF-02; air flow 5450l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35000"
          }
        },
        {
          "id": "2 - Main/288-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-51F-SPF-01; air flow 4300l/s, ESP at 500Pa and power rating of 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-51F-SPF-01; air flow 4300l/s, ESP at 500Pa and power rating of 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35000"
          }
        },
        {
          "id": "2 - Main/288-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-51F-SPF-02; air flow 4300l/s, ESP at 500Pa and power rating of 6kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-51F-SPF-02; air flow 4300l/s, ESP at 500Pa and power rating of 6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14766
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35000"
          }
        },
        {
          "id": "2 - Main/288-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-SPF-01; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-SPF-01; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14768
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-SPF-02; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-SPF-02; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14770
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-59F-SPF-01; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-59F-SPF-01; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14772
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-59F-SPF-02; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-59F-SPF-02; air flow 5250l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14774
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-SPF-01; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-SPF-01; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14776
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "35,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-SPF-02; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-SPF-02; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14778
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "35,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-57F-SPF-01; air flow 4820l/s, ESP at 500Pa and power rating of 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-57F-SPF-01; air flow 4820l/s, ESP at 500Pa and power rating of 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14780
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "35,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-57F-SPF-02; air flow 4820l/s, ESP at 500Pa and power rating of 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-57F-SPF-02; air flow 4820l/s, ESP at 500Pa and power rating of 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14782
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "35,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/288-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-SPF-01; air flow 5300l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-SPF-01; air flow 5300l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14784
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,000.00",
            "[S]": "TRUE",
            "[T]": "35000"
          }
        },
        {
          "id": "2 - Main/288-N",
          "item_code": "N",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-SPF-02; air flow 5300l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-SPF-02; air flow 5300l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14786
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,000.00",
            "[S]": "TRUE",
            "[T]": "35000"
          }
        },
        {
          "id": "2 - Main/288-P",
          "item_code": "P",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-55F-SPF-01; air flow 4770l/s, ESP at 500Pa and power rating of 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-55F-SPF-01; air flow 4770l/s, ESP at 500Pa and power rating of 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/170",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14788
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,000.00",
            "[S]": "TRUE",
            "[T]": "35000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/289",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 315000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/289-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-55F-SPF-02; air flow 4770l/s, ESP at 500Pa and power rating of 7kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-55F-SPF-02; air flow 4770l/s, ESP at 500Pa and power rating of 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,000.00",
            "[S]": "TRUE",
            "[T]": "35000"
          }
        },
        {
          "id": "2 - Main/289-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-GF-SPF; air flow 5500l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-GF-SPF; air flow 5500l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-GF-SPF; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-GF-SPF; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-SPF-01; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-SPF-01; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-GF-SPF-02; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Stair pressurization fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-GF-SPF-02; air flow 5400l/s, ESP at 500Pa and power rating of 8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "20,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-20000"
          }
        },
        {
          "id": "2 - Main/289-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-H",
          "item_code": "H",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-48F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-48F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14817
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-J",
          "item_code": "J",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14819
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "20,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-K",
          "item_code": "K",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-FPEF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14821
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE",
            "[T]": "20000"
          }
        },
        {
          "id": "2 - Main/289-L",
          "item_code": "L",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-FPEF-01; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-FPEF-01; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14823
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/289-M",
          "item_code": "M",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-FPEF-02; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump extract fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-FPEF-02; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/171",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/290",
      "section": "HVAC INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 140000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/290-A",
          "item_code": "A",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T1-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T1-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "20,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-20000"
          }
        },
        {
          "id": "2 - Main/290-B",
          "item_code": "B",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/290-C",
          "item_code": "C",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T2-48F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T2-48F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/290-D",
          "item_code": "D",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "20,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/290-E",
          "item_code": "E",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T4-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T4-30F-FPMF; air flow 2265l/s, ESP at 300Pa and power rating of 3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE",
            "[T]": "20000"
          }
        },
        {
          "id": "2 - Main/290-F",
          "item_code": "F",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-GF-FPMF; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-GF-FPMF; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/290-G",
          "item_code": "G",
          "section": "HVAC INSTALLATION",
          "heading_path": [
            "Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete"
          ],
          "own_description": "T3-P2-FPMF; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — HVAC INSTALLATION — Fire pump make-up fan; including vibration isolators/rubber mount, control panels, electrical wirings, BMS connections, supports, brackets, accessories; complete — T3-P2-FPMF; air flow 3060l/s, ESP at 500Pa and power rating of 4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/Q/172",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/291",
      "section": "LPG INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1093200,
      "section_notes": [
        "Note: Refer to the following:",
        "1. LPG floor plan (Basement to Podium) Drawing Nr. ZD-3250587-CKR-DWG-PDM-PLD-7000 to 7996",
        "2. LPG floor plan (Tower 1) Drawing Nr. ZD-3250587-CKR-DWG-TW1-PLD-7040 to 7510",
        "3. LPG floor plan (Tower 2) Drawing Nr. ZD-3250587-CKR-DWG-TW2-PLD-7040 to 7590",
        "4. LPG floor plan (Tower 3) Drawing Nr. ZD-3250587-CKR-DWG-TW3-PLD-7040 to 7550",
        "5. LPG floor plan (Tower 4) Drawing Nr. ZD-3250587-CKR-DWG-TW4-PLD-7040 to 7550",
        "6. LPG schematics Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD_7601 to 7605",
        "7. LPG supply standard details and notes Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-PLD-7501 to 7502",
        "8. MEP Specification Document Nr. ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/291-A",
          "item_code": "A",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Soft copper pipe tubes to BS EN 1057 tableX;  including fittings, perforated covers, hangers, supports, fixings, sleeves, accessories and all ancillary works as necessary"
          ],
          "own_description": "15mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Soft copper pipe tubes to BS EN 1057 tableX;  including fittings, perforated covers, hangers, supports, fixings, sleeves, accessories and all ancillary works as necessary — 15mm diameter",
          "quantity": 13665,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1093200,
          "amount_state": "number",
          "printed_page": "2/Q/173",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "486",
            "Tower 1 [E]": "2,916",
            "Tower 2 [F]": "3,415",
            "Tower 3 [G]": "3,570",
            "Tower 4 [H]": "3,278",
            "TOTAL QTY [I]": "13,665",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "38,880.00",
            "TOWER 1 [O]": "233,280.00",
            "TOWER 2 [P]": "273,200.00",
            "TOWER 3 [Q]": "285,600.00",
            "TOWER 4 [R]": "262,240.00",
            "[S]": "TRUE",
            "[T]": "28960"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/292",
      "section": "LPG INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1623181,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/292-A",
          "item_code": "A",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 20mm diameter",
          "quantity": 1209,
          "unit": "m",
          "rate_aed": 144,
          "amount_aed": 174096,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "322",
            "Tower 2 [F]": "263",
            "Tower 3 [G]": "277",
            "Tower 4 [H]": "273",
            "TOTAL QTY [I]": "1,209",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,656.00",
            "TOWER 1 [O]": "46,368.00",
            "TOWER 2 [P]": "37,872.00",
            "TOWER 3 [Q]": "39,888.00",
            "TOWER 4 [R]": "39,312.00",
            "[S]": "TRUE",
            "[T]": "-7056"
          }
        },
        {
          "id": "2 - Main/292-B",
          "item_code": "B",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "25mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 25mm diameter",
          "quantity": 1163,
          "unit": "m",
          "rate_aed": 167,
          "amount_aed": 194221,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "101",
            "Tower 2 [F]": "346",
            "Tower 3 [G]": "382",
            "Tower 4 [H]": "334",
            "TOTAL QTY [I]": "1,163",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,867.00",
            "TOWER 2 [P]": "57,782.00",
            "TOWER 3 [Q]": "63,794.00",
            "TOWER 4 [R]": "55,778.00",
            "[S]": "TRUE",
            "[T]": "38911"
          }
        },
        {
          "id": "2 - Main/292-C",
          "item_code": "C",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 32mm diameter",
          "quantity": 2529,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 505800,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "606",
            "Tower 2 [F]": "645",
            "Tower 3 [G]": "578",
            "Tower 4 [H]": "700",
            "TOTAL QTY [I]": "2,529",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "121,200.00",
            "TOWER 2 [P]": "129,000.00",
            "TOWER 3 [Q]": "115,600.00",
            "TOWER 4 [R]": "140,000.00",
            "[S]": "TRUE",
            "[T]": "18800"
          }
        },
        {
          "id": "2 - Main/292-D",
          "item_code": "D",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 40mm diameter",
          "quantity": 422,
          "unit": "m",
          "rate_aed": 287,
          "amount_aed": 121114,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14923
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "78",
            "Tower 2 [F]": "96",
            "Tower 3 [G]": "149",
            "Tower 4 [H]": "99",
            "TOTAL QTY [I]": "422",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "22,386.00",
            "TOWER 2 [P]": "27,552.00",
            "TOWER 3 [Q]": "42,763.00",
            "TOWER 4 [R]": "28,413.00",
            "[S]": "TRUE",
            "[T]": "6027"
          }
        },
        {
          "id": "2 - Main/292-E",
          "item_code": "E",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 50mm diameter",
          "quantity": 1048,
          "unit": "m",
          "rate_aed": 313,
          "amount_aed": 328024,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "174",
            "Tower 2 [F]": "388",
            "Tower 3 [G]": "64",
            "Tower 4 [H]": "348",
            "TOTAL QTY [I]": "1,048",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,162.00",
            "TOWER 1 [O]": "54,462.00",
            "TOWER 2 [P]": "121,444.00",
            "TOWER 3 [Q]": "20,032.00",
            "TOWER 4 [R]": "108,924.00",
            "[S]": "TRUE",
            "[T]": "54462"
          }
        },
        {
          "id": "2 - Main/292-F",
          "item_code": "F",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 50mm diameter",
          "quantity": 271,
          "unit": "m",
          "rate_aed": 373,
          "amount_aed": 101083,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14929
          },
          "extra_columns": {
            "Basement [C]": "271",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "271",
            "BASEMENTS [M]": "101,083.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/292-G",
          "item_code": "G",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 80mm diameter",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 573,
          "amount_aed": 80793,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14931
          },
          "extra_columns": {
            "Basement [C]": "141",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "80,793.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/292-H",
          "item_code": "H",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 including fittings, containment pipe, pipe in pipe gas detectors, socket, sensors, hangers, supports, clamps, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 100mm diameter",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 716,
          "amount_aed": 35800,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14933
          },
          "extra_columns": {
            "Basement [C]": "50",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "35,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/292-J",
          "item_code": "J",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Fire rated duct to LPG pipe"
          ],
          "own_description": "To LPG pipe in various sizes; 2hr. fire rating",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Fire rated duct to LPG pipe — To LPG pipe in various sizes; 2hr. fire rating",
          "quantity": 174,
          "unit": "m",
          "rate_aed": 400,
          "amount_aed": 69600,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "58",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "48",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "23,200.00",
            "TOWER 2 [P]": "14,800.00",
            "TOWER 3 [Q]": "19,200.00",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "-10800"
          }
        },
        {
          "id": "2 - Main/292-K",
          "item_code": "K",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 32mm diameter",
          "quantity": 55,
          "unit": "m",
          "rate_aed": 230,
          "amount_aed": 12650,
          "amount_state": "number",
          "printed_page": "2/Q/174",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,450.00",
            "TOWER 2 [P]": "2,760.00",
            "TOWER 3 [Q]": "2,990.00",
            "TOWER 4 [R]": "3,450.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/293",
      "section": "LPG INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 7172328,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/293-A",
          "item_code": "A",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "40mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 40mm diameter",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 330,
          "amount_aed": 6270,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14959
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,970.00",
            "TOWER 2 [P]": "2,640.00",
            "TOWER 3 [Q]": "660.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2970"
          }
        },
        {
          "id": "2 - Main/293-B",
          "item_code": "B",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 50mm diameter",
          "quantity": 102,
          "unit": "m",
          "rate_aed": 360,
          "amount_aed": 36720,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14961
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "27",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "26",
            "Tower 4 [H]": "30",
            "TOTAL QTY [I]": "102",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,720.00",
            "TOWER 2 [P]": "6,840.00",
            "TOWER 3 [Q]": "9,360.00",
            "TOWER 4 [R]": "10,800.00",
            "[S]": "TRUE",
            "[T]": "1080"
          }
        },
        {
          "id": "2 - Main/293-C",
          "item_code": "C",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 65mm diameter",
          "quantity": 96,
          "unit": "m",
          "rate_aed": 468,
          "amount_aed": 44928,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "34",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "28",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,424.00",
            "TOWER 2 [P]": "15,912.00",
            "TOWER 3 [Q]": "7,488.00",
            "TOWER 4 [R]": "13,104.00",
            "[S]": "TRUE",
            "[T]": "4680"
          }
        },
        {
          "id": "2 - Main/293-D",
          "item_code": "D",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 80mm diameter",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 567,
          "amount_aed": 14742,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,701.00",
            "TOWER 2 [P]": "2,835.00",
            "TOWER 3 [Q]": "7,371.00",
            "TOWER 4 [R]": "2,835.00",
            "[S]": "TRUE",
            "[T]": "1134"
          }
        },
        {
          "id": "2 - Main/293-E",
          "item_code": "E",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary"
          ],
          "own_description": "100mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Seamless carbon steel pipe to ASTM A53 Gr.B schedule 40 to roofdeck; including fittings, 200x300x200mm concrete block, G.I. pipe clamp, unifix assembly, hangers, supports, fixings, sleeves, couplers, accessories and all ancillary works as necessary — 100mm diameter",
          "quantity": 2,
          "unit": "m",
          "rate_aed": 709,
          "amount_aed": 1418,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,418.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/293-F",
          "item_code": "F",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Gas detectors",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Gas detectors",
          "quantity": 1814,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 816300,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "91",
            "Tower 1 [E]": "412",
            "Tower 2 [F]": "437",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "420",
            "TOTAL QTY [I]": "1,814",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,950.00",
            "TOWER 1 [O]": "185,400.00",
            "TOWER 2 [P]": "196,650.00",
            "TOWER 3 [Q]": "204,300.00",
            "TOWER 4 [R]": "189,000.00",
            "[S]": "TRUE",
            "[T]": "3600"
          }
        },
        {
          "id": "2 - Main/293-G",
          "item_code": "G",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Emergency shutoff switch",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Emergency shutoff switch",
          "quantity": 1756,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 614600,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14973
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "422",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "414",
            "TOTAL QTY [I]": "1,756",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,350.00",
            "TOWER 1 [O]": "141,750.00",
            "TOWER 2 [P]": "147,700.00",
            "TOWER 3 [Q]": "158,900.00",
            "TOWER 4 [R]": "144,900.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/293-H",
          "item_code": "H",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Gas regulator",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Gas regulator",
          "quantity": 1756,
          "unit": "Nr.",
          "rate_aed": 550,
          "amount_aed": 965800,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14975
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "422",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "414",
            "TOTAL QTY [I]": "1,756",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,550.00",
            "TOWER 1 [O]": "222,750.00",
            "TOWER 2 [P]": "232,100.00",
            "TOWER 3 [Q]": "249,700.00",
            "TOWER 4 [R]": "227,700.00",
            "[S]": "TRUE",
            "[T]": "4950"
          }
        },
        {
          "id": "2 - Main/293-J",
          "item_code": "J",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Isolation valve; 32mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Isolation valve; 32mm diameter",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14977
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,500.00",
            "TOWER 2 [P]": "900.00",
            "TOWER 3 [Q]": "900.00",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE",
            "[T]": "-300"
          }
        },
        {
          "id": "2 - Main/293-K",
          "item_code": "K",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Isolation valve; 50mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Isolation valve; 50mm diameter",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 750,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14979
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "3,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,500.00",
            "TOWER 2 [P]": "750.00",
            "TOWER 3 [Q]": "2,250.00",
            "TOWER 4 [R]": "1,500.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/293-L",
          "item_code": "L",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Isolation valve; 65mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Isolation valve; 65mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 975,
          "amount_aed": 1950,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14981
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "975.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "975.00",
            "[S]": "TRUE",
            "[T]": "975"
          }
        },
        {
          "id": "2 - Main/293-M",
          "item_code": "M",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary"
          ],
          "own_description": "Isolation valve; 80mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Accessories including all hangers, supports, fixings, pipe connections and ancillary work as necessary — Isolation valve; 80mm diameter",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1200,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14983
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/293-N",
          "item_code": "N",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "PRDP assembly; including PRDP box fixed with the wall, fleet support; complete"
          ],
          "own_description": "PRDP 350mBar to 75mBar, size 1200 x 600 x 300mm",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — PRDP assembly; including PRDP box fixed with the wall, fleet support; complete — PRDP 350mBar to 75mBar, size 1200 x 600 x 300mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 75000,
          "amount_aed": 300000,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14987
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "75,000.00",
            "TOWER 2 [P]": "75,000.00",
            "TOWER 3 [Q]": "75,000.00",
            "TOWER 4 [R]": "75,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/293-P",
          "item_code": "P",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Kitchen gas pipe assembly; including isolating valve, second stage regulator, solenoid valve, automatic shut-off valve, wirings, connections, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "20mm diameter",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Kitchen gas pipe assembly; including isolating valve, second stage regulator, solenoid valve, automatic shut-off valve, wirings, connections, fixings, accessories and all ancillary works as necessary — 20mm diameter",
          "quantity": 1741,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 4352500,
          "amount_state": "number",
          "printed_page": "2/Q/175",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 14991
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "404",
            "Tower 2 [F]": "413",
            "Tower 3 [G]": "453",
            "Tower 4 [H]": "410",
            "TOTAL QTY [I]": "1,741",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "152,500.00",
            "TOWER 1 [O]": "1,010,000.00",
            "TOWER 2 [P]": "1,032,500.00",
            "TOWER 3 [Q]": "1,132,500.00",
            "TOWER 4 [R]": "1,025,000.00",
            "[S]": "TRUE",
            "[T]": "15000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/294",
      "section": "LPG INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 25000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/294-A",
          "item_code": "A",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ground and podium",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary — To ground and podium",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/176",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15011
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/294-B",
          "item_code": "B",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 1",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary — To tower 1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/176",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15013
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/294-C",
          "item_code": "C",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 2",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary — To tower 2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/176",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15015
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/294-D",
          "item_code": "D",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 3",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary — To tower 3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/176",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15017
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/294-E",
          "item_code": "E",
          "section": "LPG INSTALLATION",
          "heading_path": [
            "Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary"
          ],
          "own_description": "To tower 4",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — LPG INSTALLATION — Allow to gas leak detection system; including gas leak detection control panel, interfacing to gas detectors, sound flashers, wirings and cables, conduits, connection to fire alarm system, fixings, hangers, supports, accessories and all ancillary works as necessary — To tower 4",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/Q/176",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15019
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/295",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 11139546.200000001,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/295-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all connections to existing services mains",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for all connections to existing services mains",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15057
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for earthing and bonding as specified; in particular all ductwork systems shall be provided with earth continuity protection at all joints",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for earthing and bonding as specified; in particular all ductwork systems shall be provided with earth continuity protection at all joints",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15059
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all supports, fixings, anchors, insulating blocks and anti-vibration devices where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for all supports, fixings, anchors, insulating blocks and anti-vibration devices where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15061
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all identification including painting, marking and labeling, including labeling all valves",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for all identification including painting, marking and labeling, including labeling all valves",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15063
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for flushing, cleaning, sterilization and chlorination of the completed installations as necessary",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for flushing, cleaning, sterilization and chlorination of the completed installations as necessary",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15065
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 11139546.200000001,
          "amount_aed": 11139546.200000001,
          "amount_state": "number",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15067
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,139,546.20",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/295-G",
          "item_code": "G",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15069
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/295-H",
          "item_code": "H",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing spares for Mechanical Engineering Installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for providing spares for Mechanical Engineering Installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15071
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/295-J",
          "item_code": "J",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/177",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15073
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/296",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/296-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for vibration and noise control where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — SUNDRIES — Allow for vibration and noise control where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/178",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15101
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/297",
      "section": "WORK INCIDENTAL AND BWIC",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/297-A",
          "item_code": "A",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15152
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-B",
          "item_code": "B",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for liaison with obtaining approvals and attendance on DEWA, other statutory bodies and service providers as required",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for liaison with obtaining approvals and attendance on DEWA, other statutory bodies and service providers as required",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15154
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-C",
          "item_code": "C",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15156
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-D",
          "item_code": "D",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15158
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-E",
          "item_code": "E",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15160
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-F",
          "item_code": "F",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for fire stopping all pipes, ducts and the like at penetrations through fire walls and other structures and making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for fire stopping all pipes, ducts and the like at penetrations through fire walls and other structures and making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15162
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-G",
          "item_code": "G",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15164
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-H",
          "item_code": "H",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all protective painting including removing protective coatings or wrappings and cleaning exposed surfaces for Mechanical installations.",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for all protective painting including removing protective coatings or wrappings and cleaning exposed surfaces for Mechanical installations.",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15166
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/297-J",
          "item_code": "J",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all decorative painting including removing protective coatings or wrappings and cleaning and polishing exposed surfaces for Mechanical installations.",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for all decorative painting including removing protective coatings or wrappings and cleaning and polishing exposed surfaces for Mechanical installations.",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/179",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15168
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/298",
      "section": "WORK INCIDENTAL AND BWIC",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/298-A",
          "item_code": "A",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/180",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15196
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/298-B",
          "item_code": "B",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/180",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15198
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/298-C",
          "item_code": "C",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Builders work in connection (BWIC) with Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — WORK INCIDENTAL AND BWIC — Builders work in connection (BWIC) with Mechanical Engineering Installations — Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/Q/180",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15202
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/299",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/299-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Mechanical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (2/Q) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Mechanical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/Q/181",
          "bill_ref": "2",
          "section_ref": "2/Q",
          "source": {
            "sheet": "2 - Main",
            "row": 15244
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/300",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 61086,
      "section_notes": [
        "Note: Refer to the following",
        "1. Electrical Drawing Nr. 2ZD-3250587-CKR-DWG-ZZZ-ELE-0001 to 0003, 1501 to 4503, PDM-ELE-2000 to 2996, TW1-ELE-2040 to 2530, 2601 to 2610, TW2-ELE-2040 to 2610, 2611 to 2615, TW3-ELE-2040 to 2570, TW4-ELE-2040 to 2570, 2616 to 2620, PDM-ELE-4000 to 4986, TW1-ELE-4001 to 4530, TW2-ELE-4001 to 4610, TW3-ELE-4001 to 4570, TW4-ELE-4001 to 4580 and 1B2-ELE-9125 to 4B2-ELE-9427; all inclusive",
        "2. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/300-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC"
          ],
          "own_description": "From 40A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC — From 40A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15826
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC"
          ],
          "own_description": "From 40A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC — From 40A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-02-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15828
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-B1-LL01 TO DB-T2-B1-WF1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — PVC cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/PVC/CU + 1C x 10mm² ECC — From SMDB-T2-B1-LL01 TO DB-T2-B1-WF1",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 64,
          "amount_aed": 4672,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15830
          },
          "extra_columns": {
            "Basement [C]": "73",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "4,672.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 102,
          "amount_aed": 1428,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15834
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,428.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to DB-T2-GF-SS01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T2-GF-LL03 to DB-T2-GF-SS01",
          "quantity": 8,
          "unit": "m",
          "rate_aed": 102,
          "amount_aed": 816,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15836
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "816.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to DB-T4-GF-SS01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL03 to DB-T4-GF-SS01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 102,
          "amount_aed": 1530,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15838
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,530.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-B1-LL01",
          "quantity": 113,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 18080,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15842
          },
          "extra_columns": {
            "Basement [C]": "113",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "18,080.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL04 to SMDB-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL04 to SMDB-T4-B1-LL01",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 16160,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15844
          },
          "extra_columns": {
            "Basement [C]": "101",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "16,160.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL04 to SMDB-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL04 to SMDB-T4-B2-LL01",
          "quantity": 115,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 18400,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15846
          },
          "extra_columns": {
            "Basement [C]": "115",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "115",
            "BASEMENTS [M]": "18,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/300-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 80A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 80A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-GF-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/1",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15848
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/301",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 114880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/301-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to SMDB-T3-01-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T1&3-GF-LL03 to SMDB-T3-01-BR01",
          "quantity": 133,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 21280,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "133",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "133",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-01-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-01-BR01",
          "quantity": 133,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 21280,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "133",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "133",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-02-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-02-BR01",
          "quantity": 140,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 22400,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "140",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "140",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-01-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-01-BR01",
          "quantity": 102,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 16320,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15869
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "102",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "102",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-02-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-02-BR01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15871
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T2-001) to SMDB-T2-01-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T2-001) to SMDB-T2-01-BR01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15873
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 80A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 80A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-01-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15875
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-02-LL01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15877
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 80A MCCB tap-off (BB-T2-001) to SMDB-T2-02-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 80A MCCB tap-off (BB-T2-001) to SMDB-T2-02-BR01",
          "quantity": 18,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 40A MCCB tap-off (BB-T1-003) to SMDB-T1-29-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 40A MCCB tap-off (BB-T1-003) to SMDB-T1-29-BR01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15881
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1600"
          }
        },
        {
          "id": "2 - Main/301-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 40A MCCB tap-off (BB-T1-003) to SMDB-T1-30-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 40A MCCB tap-off (BB-T1-003) to SMDB-T1-30-BR01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2400"
          }
        },
        {
          "id": "2 - Main/301-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-003) to SMDB-T1-(31-38)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 160A MCCB tap-off (BB-T1-003) to SMDB-T1-(31-38)-BR01",
          "quantity": 94,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 15040,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15885
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "94",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15040"
          }
        },
        {
          "id": "2 - Main/301-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T2-003) to SMDB-T2-29-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T2-003) to SMDB-T2-29-BR01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T2-003) to SMDB-T2-30-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T2-003) to SMDB-T2-30-BR01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15889
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,240.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T3-002-R) to SMDB-T3-29-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T3-002-R) to SMDB-T3-29-BR01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15891
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/301-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T4-002) to SMDB-T4-29-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T4-002) to SMDB-T4-29-BR01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/2",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,600.00",
            "[S]": "TRUE",
            "[T]": "1600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/302",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 139000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/302-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 63A MCCB tap-off (BB-T4-003) to SMDB-T4-30-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 63A MCCB tap-off (BB-T4-003) to SMDB-T4-30-BR01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15906
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "14",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,240.00",
            "[S]": "TRUE",
            "[T]": "2240"
          }
        },
        {
          "id": "2 - Main/302-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-002-R) to SMDB-T3-(28)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 160A MCCB tap-off (BB-T3-002-R) to SMDB-T3-(28)-BR01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 20A TP ISOLATOR FOR CWTP-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From MCC-T3-29-CHWP to 20A TP ISOLATOR FOR CWTP-01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15910
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 20A TP ISOLATOR FOR CWTP-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From MCC-T3-29-CHWP to 20A TP ISOLATOR FOR CWTP-01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-GF-LV",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-GF-LV",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15916
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-03-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-03-BR01",
          "quantity": 142,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 28400,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15918
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "142",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "142",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-03-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-03-BR01",
          "quantity": 125,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15920
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "125",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "125",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-01-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15922
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 125A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-01-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15924
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-001) to SMDB-T2-03-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-001) to SMDB-T2-03-BR01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15926
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-004) to SMDB-T2-48-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-004) to SMDB-T2-48-BR01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 2600,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15928
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-48-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15930
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-005) to SMDB-T2-(54-57)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T2-005) to SMDB-T2-(54-57)-BR01",
          "quantity": 49,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 9800,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15932
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "49",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T4-004) to SMDB-T4-(50-53)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T4-004) to SMDB-T4-(50-53)-BR01",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15934
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,400.00",
            "[S]": "TRUE",
            "[T]": "10400"
          }
        },
        {
          "id": "2 - Main/302-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-02-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-02-BR01",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15936
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "108",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/PVC/CU + 1C x 16mm² ECC — From 100A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-GF-LL01",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15938
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC — From 125A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-GF-LV01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15942
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T2-005) to SMDB-T2-(49-53)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC — From 125A MCCB tap-off (BB-T2-005) to SMDB-T2-(49-53)-BR01",
          "quantity": 57,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 14820,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15944
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "57",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,820.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC — From 125A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-48-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 3640,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15946
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/302-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/PVC/CU + 1C x 25mm² ECC — From 125A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-01-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/R/3",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15948
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/303",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 417925,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/303-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-B2-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15959
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL04 to SMDB-T4-GF-EV2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T4-GF-LL04 to SMDB-T4-GF-EV2",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 14600,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15961
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to SMDB-T3-02-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T1&3-GF-LL03 to SMDB-T3-02-BR01",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 51465,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "141",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,465.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to SMDB-T3-03-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T1&3-GF-LL03 to SMDB-T3-03-BR01",
          "quantity": 142,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 51830,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "142",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "142",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,830.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 300A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 300A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-001) to SMDB-T1-(04-15)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-001) to SMDB-T1-(04-15)-BR01",
          "quantity": 139,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 50735,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15969
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "139",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "139",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "50,735.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-50735"
          }
        },
        {
          "id": "2 - Main/303-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-002) to SMDB-T1-(16-26)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-002) to SMDB-T1-(16-26)-BR01",
          "quantity": 131,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 47815,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "131",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "47,815.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-47815"
          }
        },
        {
          "id": "2 - Main/303-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-003) to SMDB-T1-(27-28)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-003) to SMDB-T1-(27-28)-BR01",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 8760,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15973
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,760.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8760"
          }
        },
        {
          "id": "2 - Main/303-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-004) to SMDB-T1-(39-49)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-004) to SMDB-T1-(39-49)-BR01",
          "quantity": 123,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 44895,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15975
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "123",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "123",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "44,895.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-44895"
          }
        },
        {
          "id": "2 - Main/303-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-004) to SMDB-T1-50-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-004) to SMDB-T1-50-BR01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 5110,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15977
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,110.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5110"
          }
        },
        {
          "id": "2 - Main/303-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-51-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-51-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15979
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,380.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4380"
          }
        },
        {
          "id": "2 - Main/303-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-001) to SMDB-T2-(04-12)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-001) to SMDB-T2-(04-12)-BR01",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 38690,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15981
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "106",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "38,690.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-002) to SMDB-T2-(13-24)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-002) to SMDB-T2-(13-24)-BR01",
          "quantity": 143,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 52195,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15983
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "143",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "52,195.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-003) to SMDB-T2-(25-28)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-003) to SMDB-T2-(25-28)-BR01",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 18615,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15985
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "51",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,615.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/303-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-003) to SMDB-T2-(31-36)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-003) to SMDB-T2-(31-36)-BR01",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 24455,
          "amount_state": "number",
          "printed_page": "2/R/4",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 15987
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "67",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "24,455.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/304",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 661745,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/304-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-004) to SMDB-T2-(37-47)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-004) to SMDB-T2-(37-47)-BR01",
          "quantity": 124,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 45260,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "124",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "45,260.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T2-005) to SMDB-T2-58-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T2-005) to SMDB-T2-58-BR01",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10585,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16002
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "29",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,585.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to SMDB-T3-04-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T1&3-GF-LL03 to SMDB-T3-04-BR01",
          "quantity": 148,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 54020,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16004
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "148",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "148",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "54,020.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to SMDB-T3-05-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T1&3-GF-LL03 to SMDB-T3-05-BR01",
          "quantity": 151,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 55115,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16006
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "151",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "151",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "55,115.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-001-R) to SMDB-T3-(06-17)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T3-001-R) to SMDB-T3-(06-17)-BR01",
          "quantity": 146,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 53290,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "146",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "146",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "53,290.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-002-R) to SMDB-T3-(18-28)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T3-002-R) to SMDB-T3-(18-28)-BR01",
          "quantity": 123,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 44895,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16010
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "123",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "123",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "44,895.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-003-R) to SMDB-T3-(31-41)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T3-003-R) to SMDB-T3-(31-41)-BR01",
          "quantity": 121,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 44165,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16012
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "121",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "121",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "44,165.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-004-R) to SMDB-T3-(42-52)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T3-004-R) to SMDB-T3-(42-52)-BR01",
          "quantity": 124,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 45260,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16014
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "124",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "45,260.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-04-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-04-BR01",
          "quantity": 129,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 47085,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16016
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "129",
            "TOTAL QTY [I]": "129",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "47,085.00",
            "[S]": "TRUE",
            "[T]": "47085"
          }
        },
        {
          "id": "2 - Main/304-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to SMDB-T4-05-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From LV-T4-GF-LL03 to SMDB-T4-05-BR01",
          "quantity": 132,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 48180,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16018
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "132",
            "TOTAL QTY [I]": "132",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "48,180.00",
            "[S]": "TRUE",
            "[T]": "48180"
          }
        },
        {
          "id": "2 - Main/304-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T4-001) to SMDB-T4-(06-17)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T4-001) to SMDB-T4-(06-17)-BR01",
          "quantity": 140,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 51100,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16020
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "140",
            "TOTAL QTY [I]": "140",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "51,100.00",
            "[S]": "TRUE",
            "[T]": "51100"
          }
        },
        {
          "id": "2 - Main/304-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T4-002) to SMDB-T4-(18-28)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T4-002) to SMDB-T4-(18-28)-BR01",
          "quantity": 131,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 47815,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16022
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "131",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "47,815.00",
            "[S]": "TRUE",
            "[T]": "47815"
          }
        },
        {
          "id": "2 - Main/304-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T4-003) to SMDB-T4-(31-41)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T4-003) to SMDB-T4-(31-41)-BR01",
          "quantity": 121,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 44165,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16024
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "121",
            "TOTAL QTY [I]": "121",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "44,165.00",
            "[S]": "TRUE",
            "[T]": "44165"
          }
        },
        {
          "id": "2 - Main/304-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T4-004) to SMDB-T4-42-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T4-004) to SMDB-T4-42-BR01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16026
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,380.00",
            "[S]": "TRUE",
            "[T]": "4380"
          }
        },
        {
          "id": "2 - Main/304-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 125A MCCB tap-off (BB-T4-004) to SMDB-T4-(43-49)-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 125A MCCB tap-off (BB-T4-004) to SMDB-T4-(43-49)-BR01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 28835,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16028
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "79",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,835.00",
            "[S]": "TRUE",
            "[T]": "28835"
          }
        },
        {
          "id": "2 - Main/304-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 160A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-55-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16030
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,380.00",
            "[S]": "TRUE",
            "[T]": "4380"
          }
        },
        {
          "id": "2 - Main/304-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From SMDB-T3-53-BR01 to SMDB-T3-56-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From SMDB-T3-53-BR01 to SMDB-T3-56-BR01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 28835,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16032
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "79",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "28,835.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/304-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC"
          ],
          "own_description": "From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/PVC/CU + 1C x 35mm² ECC — From 100A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-01-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/5",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16034
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/305",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 182540,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/305-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-SWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-SWP",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16047
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-03-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16049
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-03-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-59-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 5400,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-55-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,300.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 200A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-01-LL01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 120mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to SMDB-T2-GF-EV2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 120mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From LV-T2-GF-LL04 to SMDB-T2-GF-EV2",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 570,
          "amount_aed": 17670,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 120mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to SMDB-T2-GF-EV2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 120mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From LV-T2-GF-LL03 to SMDB-T2-GF-EV2",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 570,
          "amount_aed": 17670,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,670.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 120mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL04 to SMDB-T4-GF-EV1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 120mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From LV-T4-GF-LL04 to SMDB-T4-GF-EV1",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 570,
          "amount_aed": 21660,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 120mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 225A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 120mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 225A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 125mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC"
          ],
          "own_description": "From 225A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 125mm² XLPE/SWA/PVC/CU + 1C x 50mm² ECC — From 225A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T2-CA-006) to MCC-T2-29-CHWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 250A MCCB tap-off (BB-T2-CA-006) to MCC-T2-29-CHWP",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 22010,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "31",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "22,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-SWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 250A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-02-SWP",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 60350,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "85",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 255A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 255A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 7810,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,810.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7810"
          }
        },
        {
          "id": "2 - Main/305-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-02-LL01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16083
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/305-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 70mm² ECC — From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 7810,
          "amount_state": "number",
          "printed_page": "2/R/6",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,810.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7810"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/306",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 269820,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/306-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to EMCC-T2-01-FAN-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From EMDB-T2-GF-LV02 to EMCC-T2-01-FAN-01",
          "quantity": 157,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 111470,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "157",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "157",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "111,470.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 250A MCCB tap-off (BB-T2-CA-006) to SMDB-T2-03-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 9230,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,230.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 300A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 300A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 250A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-03-LL01",
          "quantity": null,
          "unit": "",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "empty",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16103
          }
        },
        {
          "id": "2 - Main/306-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-B2-LL01",
          "quantity": null,
          "unit": "",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "empty",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16105
          }
        },
        {
          "id": "2 - Main/306-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T4-CA-005) to MCC-T4-29-CHWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 200A MCCB tap-off (BB-T4-CA-005) to MCC-T4-29-CHWP",
          "quantity": null,
          "unit": "",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "empty",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16107
          }
        },
        {
          "id": "2 - Main/306-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-GF-EV1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-GF-EV1",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 300A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 300A MCCB tap-off (BB-T3-CA-006) to SMDB-T3-29-LL01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 8750,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 300A MCCB tap-off (BB-T3-004-R) to SMDB-T3-53-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 300A MCCB tap-off (BB-T3-004-R) to SMDB-T3-53-BR01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "14,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 300A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 300A MCCB tap-off (BB-T1-CA-005) to SMDB-T1-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC"
          ],
          "own_description": "From 400A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/PVC/CU + 1C x 95mm² ECC — From 400A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 9625,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,625.00",
            "[S]": "TRUE",
            "[T]": "9625"
          }
        },
        {
          "id": "2 - Main/306-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 X 4C x 300mm² XLPE/SWA/PVC/CU + 1C x 185mm² ECC"
          ],
          "own_description": "From 400A MCCB tap-off (BB-T3-CA-006) to ESMDB-T3-57-LIFT1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 X 4C x 300mm² XLPE/SWA/PVC/CU + 1C x 185mm² ECC — From 400A MCCB tap-off (BB-T3-CA-006) to ESMDB-T3-57-LIFT1",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 11375,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "11,375.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 X 4C x 300mm² XLPE/SWA/PVC/CU + 1C x 185mm² ECC"
          ],
          "own_description": "From 400A MCCB tap-off (BB-T3-CA-006) to ESMDB-T3-57-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 X 4C x 300mm² XLPE/SWA/PVC/CU + 1C x 185mm² ECC — From 400A MCCB tap-off (BB-T3-CA-006) to ESMDB-T3-57-LIFT2",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 12250,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 150mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to SMDB-T1-GF-EV2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 150mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC — From LV-T1-GF-LL06 to SMDB-T1-GF-EV2",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 1420,
          "amount_aed": 51120,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 150mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC"
          ],
          "own_description": "From 500A MCCB tap-off (BB-T1-CA-005) to ESMDB-T1-51-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 150mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC — From 500A MCCB tap-off (BB-T1-CA-005) to ESMDB-T1-51-LIFT",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/306-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 185mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC"
          ],
          "own_description": "From 630A MCCB tap-off (BB-T1-CA-005) to ESMDB-T1-51-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 185mm² XLPE/SWA/PVC/CU + 2 x 1C x 70mm² ECC — From 630A MCCB tap-off (BB-T1-CA-005) to ESMDB-T1-51-LIFT",
          "quantity": 12,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/7",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/307",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 675020,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/307-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/PVC/CU + 2 x 1C x 120mm² ECC"
          ],
          "own_description": "From 630A MCCB tap-off (BB-T2-CA-006) to ESMDB-T2-59-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/PVC/CU + 2 x 1C x 120mm² ECC — From 630A MCCB tap-off (BB-T2-CA-006) to ESMDB-T2-59-LIFT",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 2270,
          "amount_aed": 29510,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "29,510.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/PVC/CU + 2 x 1C x 120mm² ECC"
          ],
          "own_description": "From 630A MCCB tap-off (BB-T4-CA-005) to ESMDB-T4-55-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/PVC/CU + 2 x 1C x 120mm² ECC — From 630A MCCB tap-off (BB-T4-CA-005) to ESMDB-T4-55-LIFT",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 2270,
          "amount_aed": 29510,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,510.00",
            "[S]": "TRUE",
            "[T]": "29510"
          }
        },
        {
          "id": "2 - Main/307-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to 350kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T1&3-GF-LL03 to 350kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL01 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T1-GF-LL01 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL02 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T1-GF-LL02 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to 350kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T1-GF-LL06 to 350kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL01 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T2-GF-LL01 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL02 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T2-GF-LL02 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T2-GF-LL03 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to 350kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T2-GF-LL04 to 350kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T3-GF-LL04 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T3-GF-LL04 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T3-GF-LL05 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T3-GF-LL05 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/307-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T3-GF-LL07 to 350kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T3-GF-LL07 to 350kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/8",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/308",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 404256,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/308-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL01 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T4-GF-LL01 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/308-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL02 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T4-GF-LL02 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/308-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL03 to 300kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T4-GF-LL03 to 300kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/308-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T4-GF-LL04 to 350kVAR Capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/PVC/CU + 2 x 1C x 150mm² ECC — From LV-T4-GF-LL04 to 350kVAR Capacitor bank",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 2800,
          "amount_aed": 56000,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "56,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/308-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/PVC/CU + 4 x 1C x 150mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to EMDB-T2-GF-LV02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/PVC/CU + 4 x 1C x 150mm² ECC — From LV-T2-GF-LL03 to EMDB-T2-GF-LV02",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 5600,
          "amount_aed": 173600,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "173,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/308-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING1)",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 992,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "31",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "992.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-992"
          }
        },
        {
          "id": "2 - Main/308-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING2)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "896.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-896"
          }
        },
        {
          "id": "2 - Main/308-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING3)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,216.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1216"
          }
        },
        {
          "id": "2 - Main/308-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,216.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1216"
          }
        },
        {
          "id": "2 - Main/308-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING5)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1184,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,184.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1184"
          }
        },
        {
          "id": "2 - Main/308-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1-51-LIFT to 20A SP isolator for lift lighting (ISO-T1-LIFT LIGHTING6)",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1152,
          "amount_state": "number",
          "printed_page": "2/R/9",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,152.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1152"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/309",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 15104,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/309-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING1)",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 992,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "31",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "992.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING2)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "28",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "896.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING3)",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1248,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,248.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "38",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,216.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING5)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1184,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,184.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T2-59-LIFT to 20A SP isolator for lift lighting (ISO-T2-LIFT LIGHTING6)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1184,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,184.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING1)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "28",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "896.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING2)",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT1 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING3)",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1152,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,152.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING4)",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1248,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "39",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,248.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING5)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "38",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,216.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T3-57-LIFT2 to 20A SP isolator for lift lighting (ISO-T3-LIFT LIGHTING6)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1184,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "37",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,184.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/309-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING1)",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 992,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "992.00",
            "[S]": "TRUE",
            "[T]": "992"
          }
        },
        {
          "id": "2 - Main/309-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING2)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 896,
          "amount_state": "number",
          "printed_page": "2/R/10",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "28",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "896.00",
            "[S]": "TRUE",
            "[T]": "896"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/310",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 35122,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/310-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING3)",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1248,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16263
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "39",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,248.00",
            "[S]": "TRUE",
            "[T]": "1248"
          }
        },
        {
          "id": "2 - Main/310-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,216.00",
            "[S]": "TRUE",
            "[T]": "1216"
          }
        },
        {
          "id": "2 - Main/310-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING5)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1216,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,216.00",
            "[S]": "TRUE",
            "[T]": "1216"
          }
        },
        {
          "id": "2 - Main/310-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — LSOH cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-55-LIFT to 20A SP isolator for lift lighting (ISO-T4-LIFT LIGHTING6)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 32,
          "amount_aed": 1184,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,184.00",
            "[S]": "TRUE",
            "[T]": "1184"
          }
        },
        {
          "id": "2 - Main/310-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 4mm² XLPE/SWA/LSOH + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T4-B2-LL01 to 20A TP isolator for CP-PB-04 (Lifting Station)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 4mm² XLPE/SWA/LSOH + 1C x 4mm² ECC — From ESMDB-T4-B2-LL01 to 20A TP isolator for CP-PB-04 (Lifting Station)",
          "quantity": 87,
          "unit": "m",
          "rate_aed": 34,
          "amount_aed": 2958,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16273
          },
          "extra_columns": {
            "Basement [C]": "87",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "2,958.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC (MAINTENANCE BYPASS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC (MAINTENANCE BYPASS)",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC (REDUNDANT)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 20A TP isolator for ISO-T1-GF-UPS1-FCC (REDUNDANT)",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 32A TP isolator for ISO-T4-GF-SEC1 (MAINTENANCE BYPASS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 32A TP isolator for ISO-T4-GF-SEC1 (MAINTENANCE BYPASS)",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 6360,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 32A TP isolator for ISO-T4-GF-SEC1 (REDUNDANT)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 32A TP isolator for ISO-T4-GF-SEC1 (REDUNDANT)",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 6360,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 80A TP isolator for ISO-T4-GF-SEC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 80A TP isolator for ISO-T4-GF-SEC1",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 6360,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/310-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to 20A TP isolator for CHEMI DOZ UNIT - GF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T2-GF-LV to 20A TP isolator for CHEMI DOZ UNIT - GF",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/R/11",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/311",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 99420,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/311-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to 20A TP isolator for DOZ CIRCULATION PUMP - GF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T2-GF-LV to 20A TP isolator for DOZ CIRCULATION PUMP - GF",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-LL01 to 20A TP isolator for AHU-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T4-GF-LL01 to 20A TP isolator for AHU-01",
          "quantity": 99,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 5940,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16306
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "99",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-LL01 to 20A TP isolator for AHU-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T4-GF-LL01 to 20A TP isolator for AHU-02",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 4500,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16308
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1",
          "quantity": 192,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 11520,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16310
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1 (MAINTENANCE BYPASS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1 (MAINTENANCE BYPASS)",
          "quantity": 192,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 11520,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16312
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1 (REDUNDANT)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From ESMDB-T4-30-LL01 to 32A TP isolator for ISO-T4-GF-UPS1 (REDUNDANT)",
          "quantity": 192,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 11520,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16314
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T1-29-CHWP to 20A TP isolator for CHEMI DOZ UNIT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T1-29-CHWP to 20A TP isolator for CHEMI DOZ UNIT",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3060,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16316
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "51",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,060.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3060"
          }
        },
        {
          "id": "2 - Main/311-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T1-29-CHWP to 20A TP isolator for DOZ CIRCULATION PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T1-29-CHWP to 20A TP isolator for DOZ CIRCULATION PUMP",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16318
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "52",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3120"
          }
        },
        {
          "id": "2 - Main/311-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 20A TP isolator for CHEMI DOZ UNIT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T3-29-CHWP to 20A TP isolator for CHEMI DOZ UNIT",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16320
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,120.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 20A TP isolator for DOZ CIRCULATION PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T3-29-CHWP to 20A TP isolator for DOZ CIRCULATION PUMP",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3180,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16322
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,180.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T1-51-LL01 to 20A TP isolator for CP-T1-51-BCPW1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T1-51-LL01 to 20A TP isolator for CP-T1-51-BCPW1",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16324
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "34",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2040"
          }
        },
        {
          "id": "2 - Main/311-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From SMDB-T1-51-LL01 to 20A TP isolator for CP-T1-51-BCPW2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From SMDB-T1-51-LL01 to 20A TP isolator for CP-T1-51-BCPW2",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "34",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2040"
          }
        },
        {
          "id": "2 - Main/311-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP2 to 20A TP isolator CHEMI DOZ UNIT-GF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T2-B1-CHWP2 to 20A TP isolator CHEMI DOZ UNIT-GF",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2100,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP2 to 20A TP isolator CIRCULATION PUMP UNIT-GF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 6mm² XLPE/SWA/LSOH + 1C x 6mm² ECC — From MCC-T2-B1-CHWP2 to 20A TP isolator CIRCULATION PUMP UNIT-GF",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-B1-LL01 to DB-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-B1-LL01 to DB-T1-B1-LL01",
          "quantity": 17,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1360,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16334
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "1,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-B1-LL01 to DB-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-B1-LL01 to DB-T3-B1-LL01",
          "quantity": 207,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16560,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16336
          },
          "extra_columns": {
            "Basement [C]": "207",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "207",
            "BASEMENTS [M]": "16,560.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-B1-LL01 to DB-T2-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-B1-LL01 to DB-T2-B1-LL01",
          "quantity": 17,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1360,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16338
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "1,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-B1-LL01 to DB-T2-B1-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-B1-LL01 to DB-T2-B1-LL02",
          "quantity": 137,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10960,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16340
          },
          "extra_columns": {
            "Basement [C]": "137",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "137",
            "BASEMENTS [M]": "10,960.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/311-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-B1-LL01 to DB-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-B1-LL01 to DB-T4-B1-LL01",
          "quantity": 18,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1440,
          "amount_state": "number",
          "printed_page": "2/R/12",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16342
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "1,440.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/312",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 110600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/312-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-B1-LL01 to DB-T4-B1-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-B1-LL01 to DB-T4-B1-LL02",
          "quantity": 18,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1440,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16354
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "1,440.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-B2-LL01 to EDB-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-B2-LL01 to EDB-T4-B2-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1120,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16356
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "1,120.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-B2-LL01 to DB-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-B2-LL01 to DB-T1-B2-LL01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16358
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "1,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-B2-LL01 to DB-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-B2-LL01 to DB-T3-B2-LL01",
          "quantity": 182,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 14560,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16360
          },
          "extra_columns": {
            "Basement [C]": "182",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "182",
            "BASEMENTS [M]": "14,560.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-B2-LL01 to DB-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-B2-LL01 to DB-T2-B2-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1120,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16362
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "1,120.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-B2-LL01 to DB-T2-B2-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-B2-LL01 to DB-T2-B2-LL02",
          "quantity": 134,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10720,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16364
          },
          "extra_columns": {
            "Basement [C]": "134",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "134",
            "BASEMENTS [M]": "10,720.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-B2-LL01 to DB-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-B2-LL01 to DB-T4-B2-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16366
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "1,040.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-B2-LL01 to DB-T4-B2-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-B2-LL01 to DB-T4-B2-LL02",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16368
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "1,040.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-B2-LL01 to EDB-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T4-B2-LL01 to EDB-T4-B1-LL01",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1840,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16370
          },
          "extra_columns": {
            "Basement [C]": "23",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "1,840.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to EDB-T1-GF-MTR",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From ESMDB-T1&3-GF-LV-01 to EDB-T1-GF-MTR",
          "quantity": 142,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16372
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "142",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "142",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to DB-T1&3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-GF-LV01 to DB-T1&3-GF-LL01",
          "quantity": 121,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 9680,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16374
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "121",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "121",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to DB-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-GF-LV01 to DB-T1-GF-LL01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1280,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16376
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to DB-T1-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-GF-LV01 to DB-T1-GF-LL02",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16378
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to DB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-GF-LV01 to DB-T3-GF-LL01",
          "quantity": 207,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16560,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16380
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "207",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "207",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to DB-T2-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV to DB-T2-GF-LL02",
          "quantity": 165,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16382
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "165",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "165",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to DB-T2-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV to DB-T2-GF-LV01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16384
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to DB-T2-GF-WF1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV to DB-T2-GF-WF1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16386
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/312-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-LL01 to DB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-GF-LL01 to DB-T4-GF-LL01",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6560,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16388
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-LL01 to DB-T4-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-GF-LL01 to DB-T4-GF-LV01",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16390
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV to DB-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV to DB-T2-GF-LL01",
          "quantity": 91,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7280,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16392
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "91",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "91",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/312-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-BR01 to DB-T1-01-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-BR01 to DB-T1-01-1BD1",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/13",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16394
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/313",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 73360,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/313-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-BR01 to DB-T1-01-1BE1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-BR01 to DB-T1-01-1BE1",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2480,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16410
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-BR01 to DB-T1-01-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-BR01 to DB-T1-01-2BB1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16412
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-BR01 to DB-T1-01-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-BR01 to DB-T1-01-2BC1",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16414
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-LL01 to DB-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-LL01 to DB-T1-01-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16416
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-LL01 to DB-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-01-LL01 to DB-T3-01-LL01",
          "quantity": 216,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17280,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16418
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "216",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "216",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-BR01 to DB-T2-01-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-BR01 to DB-T2-01-1BB1",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16420
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-BR01 to DB-T2-01-1BG1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-BR01 to DB-T2-01-1BG1",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16422
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-BR01 to DB-T2-01-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-BR01 to DB-T2-01-2BA1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16424
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to DB-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-LL01 to DB-T2-01-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16426
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to DB-T2-01-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-LL01 to DB-T2-01-LL02",
          "quantity": 148,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 11840,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "148",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "148",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-01-BR01 to DB-T3-01-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-01-BR01 to DB-T3-01-1BB1",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16430
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-01-BR01 to DB-T3-01-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-01-BR01 to DB-T3-01-2BB1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16432
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-01-BR01 to DB-T3-01-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-01-BR01 to DB-T3-01-2BC1",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1840,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16434
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-BR01 to DB-T4-01-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-01-BR01 to DB-T4-01-1BB1",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-BR01 to DB-T4-01-1BG1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-01-BR01 to DB-T4-01-1BG1",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-BR01 to DB-T4-01-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-01-BR01 to DB-T4-01-2BA1",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-BR01 to DB-T4-01-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-01-BR01 to DB-T4-01-2BA2",
          "quantity": 47,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3760,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "47",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-LL01 to DB-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-01-LL01 to DB-T4-01-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-BR01 to DB-T1-L02-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-BR01 to DB-T1-L02-1BD1",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-BR01 to DB-T1-L02-1BE1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-BR01 to DB-T1-L02-1BE1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-BR01 to DB-T1-L02-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-BR01 to DB-T1-L02-2BB1",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3680,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16450
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "46",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/313-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-BR01 to DB-T1-L02-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-BR01 to DB-T1-L02-2BC1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/14",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16452
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/314",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 92880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/314-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-BR01 to DB-T1-L02-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-BR01 to DB-T1-L02-3BB1",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-LL01 to DB-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-LL01 to DB-T1-02-LL01",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-02-LL01 to DB-T3-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-02-LL01 to DB-T3-02-LL01",
          "quantity": 231,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 18480,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "231",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "231",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-BR01 to DB-T2-L02-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-BR01 to DB-T2-L02-1BB1",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-BR01 to DB-T2-L02-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-BR01 to DB-T2-L02-1BC1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-BR01 to DB-T2-L02-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-BR01 to DB-T2-L02-1BC2",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-BR01 to DB-T2-L02-1BG1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-BR01 to DB-T2-L02-1BG1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-BR01 to DB-T2-L02-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-BR01 to DB-T2-L02-2BA1",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2560,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-LL01 to DB-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-LL01 to DB-T2-02-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1120,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-LL01 to DB-T2-02-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-LL01 to DB-T2-02-LL02",
          "quantity": 155,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "155",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "155",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-02-LL01 to DB-T2-02-LL03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-02-LL01 to DB-T2-02-LL03",
          "quantity": 157,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12560,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "157",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "157",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-02-BR01 to DB-T3-L02-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-02-BR01 to DB-T3-L02-1BB1",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2480,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-02-BR01 to DB-T3-L02-1BB2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-02-BR01 to DB-T3-L02-1BB2",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1840,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-02-BR01 to DB-T3-L02-1BG1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-02-BR01 to DB-T3-L02-1BG1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-02-BR01 to DB-T3-L02-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-02-BR01 to DB-T3-L02-2BB1",
          "quantity": 47,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3760,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "47",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-02-BR01 to DB-T3-L02-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-02-BR01 to DB-T3-L02-2BC1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-1BB1",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-1BC1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16499
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-1BC2",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16501
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-1BG2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-1BG2",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-2BA1",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16505
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/314-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-BR01 to DB-T4-L02-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-BR01 to DB-T4-L02-2BA2",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4240,
          "amount_state": "number",
          "printed_page": "2/R/15",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "53",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/315",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 61280,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/315-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-LL01 to DB-T4-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-02-LL01 to DB-T4-02-LL01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1280,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-1BA1",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3680,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "46",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-1BD1",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-2BB1",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3440,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "43",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-2BC1",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-3BB1",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-BR01 to DB-T1-L03-3BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-BR01 to DB-T1-L03-3BD1",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-03-EXT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-03-EXT",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6560,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16534
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-03-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16536
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV-01 to EDB-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV-01 to EDB-T2-GF-LL01",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16538
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-LV-01 to EDB-T2-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-GF-LV-01 to EDB-T2-GF-LL02",
          "quantity": 8,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 640,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16540
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-1BA1",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16542
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-1BB1",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16544
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-1BC1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-1BC2",
          "quantity": 41,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3280,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "41",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-2BA1",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16550
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-2BA2",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4160,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16552
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-BR01 to DB-T2-L03-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-BR01 to DB-T2-L03-2BB1",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16554
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-03-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-03-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-03-LL02",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-1BA1",
          "quantity": 47,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3760,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "47",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-1BB1",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-2BB1",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/315-Z",
          "item_code": "Z",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-2BC1",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/16",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16566
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/316",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 119760,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/316-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-3BA1",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-BR01 to DB-T3-L03-3BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-BR01 to DB-T3-L03-3BD1",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2560,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-03-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-1BB1",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-1BC1",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-1BC2",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-2BA1",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-2BA2",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4080,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-BR01 to DB-T4-03-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-BR01 to DB-T4-03-2BB1",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16597
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-03-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-03-LL02",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1200,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-06-LL01",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2080,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2080"
          }
        },
        {
          "id": "2 - Main/316-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-09-LL01",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2880"
          }
        },
        {
          "id": "2 - Main/316-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-12-LL01",
          "quantity": 47,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3760,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "47",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,760.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3760"
          }
        },
        {
          "id": "2 - Main/316-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-15-LL01",
          "quantity": 57,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "57",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4560"
          }
        },
        {
          "id": "2 - Main/316-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-18-LL01",
          "quantity": 68,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5440,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "68",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "68",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,440.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5440"
          }
        },
        {
          "id": "2 - Main/316-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-21-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-24-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/316-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-03-LL01 to DB-T1-27-LL01",
          "quantity": 99,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7920,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "99",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7920"
          }
        },
        {
          "id": "2 - Main/316-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BA1",
          "quantity": 471,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37680,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "471",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "471",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "37,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-37680"
          }
        },
        {
          "id": "2 - Main/316-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BC1",
          "quantity": 388,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31040,
          "amount_state": "number",
          "printed_page": "2/R/17",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "388",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "388",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31040"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/317",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 399600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/317-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BC2",
          "quantity": 389,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31120,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16634
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "389",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "389",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31120"
          }
        },
        {
          "id": "2 - Main/317-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-1BD1",
          "quantity": 221,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17680,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16636
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "221",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "221",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17680"
          }
        },
        {
          "id": "2 - Main/317-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BA1",
          "quantity": 355,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28400,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16638
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "355",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "355",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28400"
          }
        },
        {
          "id": "2 - Main/317-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BA2",
          "quantity": 506,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 40480,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16640
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "506",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "506",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "40,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-40480"
          }
        },
        {
          "id": "2 - Main/317-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BB1",
          "quantity": 449,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35920,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16642
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "449",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35920"
          }
        },
        {
          "id": "2 - Main/317-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-2BC1",
          "quantity": 224,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17920,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16644
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "224",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,920.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17920"
          }
        },
        {
          "id": "2 - Main/317-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(04-15)-BR01 to DB-T1-(04-15)-3BB1",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16646
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "300",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-24000"
          }
        },
        {
          "id": "2 - Main/317-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BA1",
          "quantity": 432,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 34560,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16648
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "432",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "432",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "34,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-34560"
          }
        },
        {
          "id": "2 - Main/317-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BC1",
          "quantity": 357,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28560,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16650
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "357",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "357",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28560"
          }
        },
        {
          "id": "2 - Main/317-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BC2",
          "quantity": 357,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28560,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16652
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "357",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "357",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28560"
          }
        },
        {
          "id": "2 - Main/317-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-1BD1",
          "quantity": 203,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16240,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16654
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "203",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "203",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16240"
          }
        },
        {
          "id": "2 - Main/317-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BA1",
          "quantity": 326,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26080,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "326",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "326",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26080"
          }
        },
        {
          "id": "2 - Main/317-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BA2",
          "quantity": 464,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37120,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "464",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "464",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "37,120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-37120"
          }
        },
        {
          "id": "2 - Main/317-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BB1",
          "quantity": 412,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 32960,
          "amount_state": "number",
          "printed_page": "2/R/18",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16660
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "412",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "32,960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-32960"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/318",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 94640,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/318-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-2BC1",
          "quantity": 206,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16480,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16673
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "206",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16480"
          }
        },
        {
          "id": "2 - Main/318-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(16-26)-BR01 to DB-T1-(16-26)-3BB1",
          "quantity": 276,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 22080,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16675
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "276",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "276",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "22,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-22080"
          }
        },
        {
          "id": "2 - Main/318-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BA1",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16677
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "79",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6320"
          }
        },
        {
          "id": "2 - Main/318-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BC1",
          "quantity": 65,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5200,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16679
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "65",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5200"
          }
        },
        {
          "id": "2 - Main/318-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BC2",
          "quantity": 65,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5200,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "65",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5200"
          }
        },
        {
          "id": "2 - Main/318-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-1BD1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2960"
          }
        },
        {
          "id": "2 - Main/318-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BA1",
          "quantity": 60,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4800,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16685
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "60",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4800"
          }
        },
        {
          "id": "2 - Main/318-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BA2",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6800,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "85",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6800"
          }
        },
        {
          "id": "2 - Main/318-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BB1",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "75",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6000"
          }
        },
        {
          "id": "2 - Main/318-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-2BC1",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3040"
          }
        },
        {
          "id": "2 - Main/318-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(27-28)-BR01 to DB-T1-(27-28)-3BB1",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4080,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "51",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4080"
          }
        },
        {
          "id": "2 - Main/318-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/318-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-1BD1",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2480,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "31",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2480"
          }
        },
        {
          "id": "2 - Main/318-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-1BF1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-1BF1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "42",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3360"
          }
        },
        {
          "id": "2 - Main/318-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-2BB1",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5840,
          "amount_state": "number",
          "printed_page": "2/R/19",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "73",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5840"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/319",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 213760,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/319-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(29-30)-BR01 to DB-T1-(29-30)-2BC1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16714
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2960"
          }
        },
        {
          "id": "2 - Main/319-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-32-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16716
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "25",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2000"
          }
        },
        {
          "id": "2 - Main/319-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-35-LL01",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16718
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2880"
          }
        },
        {
          "id": "2 - Main/319-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-38-LL01",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3680,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16720
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3680"
          }
        },
        {
          "id": "2 - Main/319-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-41-LL01",
          "quantity": 57,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "57",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4560"
          }
        },
        {
          "id": "2 - Main/319-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-44-LL01",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5360,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "67",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5360"
          }
        },
        {
          "id": "2 - Main/319-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-47-LL01",
          "quantity": 78,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6240,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "78",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6240"
          }
        },
        {
          "id": "2 - Main/319-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-29-LL01 to DB-T1-50-LL01",
          "quantity": 93,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7440,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16728
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "93",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,440.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7440"
          }
        },
        {
          "id": "2 - Main/319-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BA1",
          "quantity": 316,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25280,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16730
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "316",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "316",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,280.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-25280"
          }
        },
        {
          "id": "2 - Main/319-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BC1",
          "quantity": 260,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 20800,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16732
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "260",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "260",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "20,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-20800"
          }
        },
        {
          "id": "2 - Main/319-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BC2",
          "quantity": 261,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 20880,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "261",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "261",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "20,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-20880"
          }
        },
        {
          "id": "2 - Main/319-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-1BD1",
          "quantity": 146,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 11680,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "146",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "146",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-11680"
          }
        },
        {
          "id": "2 - Main/319-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BA1",
          "quantity": 343,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 27440,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "343",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "343",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "27,440.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-27440"
          }
        },
        {
          "id": "2 - Main/319-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BA2",
          "quantity": 243,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19440,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16740
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "243",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "243",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "19,440.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-19440"
          }
        },
        {
          "id": "2 - Main/319-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BB1",
          "quantity": 304,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24320,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "304",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "304",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "24,320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-24320"
          }
        },
        {
          "id": "2 - Main/319-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-2BC1",
          "quantity": 154,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "154",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "154",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12320"
          }
        },
        {
          "id": "2 - Main/319-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(31-38)-BR01 to DB-T1-(31-38)-3BB1",
          "quantity": 206,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16480,
          "amount_state": "number",
          "printed_page": "2/R/20",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "206",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16480"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/320",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 290080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/320-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BA1",
          "quantity": 438,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35040,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "438",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "438",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "35,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-35040"
          }
        },
        {
          "id": "2 - Main/320-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BC1",
          "quantity": 364,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29120,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "364",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "29,120.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-29120"
          }
        },
        {
          "id": "2 - Main/320-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BC2",
          "quantity": 363,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29040,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16766
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "363",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "363",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "29,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-29040"
          }
        },
        {
          "id": "2 - Main/320-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BD1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-1BD1",
          "quantity": 200,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16000,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16768
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "200",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16000"
          }
        },
        {
          "id": "2 - Main/320-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BA1",
          "quantity": 471,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37680,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16770
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "471",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "471",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "37,680.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-37680"
          }
        },
        {
          "id": "2 - Main/320-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BA2",
          "quantity": 334,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26720,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16772
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "334",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "334",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,720.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26720"
          }
        },
        {
          "id": "2 - Main/320-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BB1",
          "quantity": 417,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 33360,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16774
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "417",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "417",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "33,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-33360"
          }
        },
        {
          "id": "2 - Main/320-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-2BC1",
          "quantity": 211,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16880,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16776
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "211",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "211",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16880"
          }
        },
        {
          "id": "2 - Main/320-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-3BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-(39-49)-BR01 to DB-T1-(39-49)-3BB1",
          "quantity": 279,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 22320,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16778
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "279",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "279",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "22,320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-22320"
          }
        },
        {
          "id": "2 - Main/320-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-50-BR01 to DB-T1-50-6B1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-50-BR01 to DB-T1-50-6B1",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16780
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-960"
          }
        },
        {
          "id": "2 - Main/320-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T1-50-BR01 to DB-T1-50-6B2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T1-50-BR01 to DB-T1-50-6B2",
          "quantity": 56,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4480,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16782
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "56",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4480"
          }
        },
        {
          "id": "2 - Main/320-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to DB-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-LL01 to DB-T2-02-LL01",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 80,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16784
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to DB-T2-02-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-LL01 to DB-T2-02-LL02",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16786
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "79",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to DB-T2-02-LL03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-01-LL01 to DB-T2-02-LL03",
          "quantity": 83,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6640,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16788
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "83",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-06-LL01",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16790
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "27",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-09-LL01",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16792
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-12-LL01",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16794
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "48",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-15-LL01",
          "quantity": 58,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16796
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "58",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-18-LL01",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16798
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "69",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,520.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/320-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-21-LL01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/21",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16800
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "79",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/321",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 346560,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/321-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-24-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "90",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-03-LL01 to DB-T2-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-03-LL01 to DB-T2-27-LL01",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16817
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "100",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BA1",
          "quantity": 354,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28320,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16819
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "354",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "354",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BB1",
          "quantity": 246,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19680,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16821
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "246",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "246",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "19,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BC1",
          "quantity": 292,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23360,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16823
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "292",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "292",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-1BC2",
          "quantity": 292,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23360,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "292",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "292",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BA1",
          "quantity": 272,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21760,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "272",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "272",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "21,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BA2",
          "quantity": 381,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 30480,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16829
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "381",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "381",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "30,480.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BB1",
          "quantity": 336,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26880,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "336",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "336",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,880.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-2BC1",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13600,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(04-12)-BR01 to DB-T2-(04-12)-3BA1",
          "quantity": 223,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17840,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "223",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "223",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "17,840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BA1",
          "quantity": 472,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37760,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "472",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "472",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "37,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BB1",
          "quantity": 327,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26160,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "327",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "327",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BC1",
          "quantity": 388,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31040,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "388",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "388",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/321-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-1BC2",
          "quantity": 389,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31120,
          "amount_state": "number",
          "printed_page": "2/R/22",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "389",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "389",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/322",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 239760,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/322-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BA1",
          "quantity": 362,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28960,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16856
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "362",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "362",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BA2",
          "quantity": 508,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 40640,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16858
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "508",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "508",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "40,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BB1",
          "quantity": 448,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35840,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16860
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "448",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "448",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-2BC1",
          "quantity": 226,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 18080,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16862
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "226",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "226",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(13-24)-BR01 to DB-T2-(13-24)-3BA1",
          "quantity": 297,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23760,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16864
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "297",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "297",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BA1",
          "quantity": 158,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12640,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16866
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "158",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "158",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BB1",
          "quantity": 110,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8800,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16868
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "110",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BC1",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16870
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-1BC2",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10400,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16872
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BA1",
          "quantity": 121,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 9680,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16874
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "121",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "121",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BA2",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13600,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16876
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "170",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BB1",
          "quantity": 150,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16878
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "150",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "150",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-2BC1",
          "quantity": 76,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6080,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16880
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "76",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(25-28)-BR01 to DB-T2-(25-28)-3BA1",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16882
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "100",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/322-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 880,
          "amount_state": "number",
          "printed_page": "2/R/23",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16884
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "880.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/323",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 156480,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/323-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-2BB1",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16899
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "74",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-2BC1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16901
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(29-30)-BR01 to DB-T2-(29-30)-3BA1",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16903
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-32-LL01",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "29",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-35-LL01",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "40",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-38-LL01",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "50",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-41-LL01",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4880,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "61",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,880.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-44-LL01",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5680,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16913
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "71",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to DB-T2-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-29-LL01 to DB-T2-47-LL01",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6560,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "82",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BA1",
          "quantity": 239,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19120,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "239",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "239",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "19,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BB1",
          "quantity": 164,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13120,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "164",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BC1",
          "quantity": 200,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16000,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "200",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "16,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-1BC2",
          "quantity": 199,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15920,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16923
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "199",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "199",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "15,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BA1",
          "quantity": 182,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 14560,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16925
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "182",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "182",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BA2",
          "quantity": 258,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 20640,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "258",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "258",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/323-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BB1",
          "quantity": 225,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/R/24",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "225",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "225",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/324",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 288080,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/324-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-2BC1",
          "quantity": 114,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 9120,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16946
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "114",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(31-36)-BR01 to DB-T2-(31-36)-3BA1",
          "quantity": 149,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 11920,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16948
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "149",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "149",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BA1",
          "quantity": 438,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35040,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16950
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "438",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "438",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "35,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BB1",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16952
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "300",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "24,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BC1",
          "quantity": 365,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29200,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16954
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "365",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "365",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "29,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-1BC2",
          "quantity": 364,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29120,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16956
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "364",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "29,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BA1",
          "quantity": 332,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26560,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "332",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BA2",
          "quantity": 472,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37760,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "472",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "472",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "37,760.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BB1",
          "quantity": 412,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 32960,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "412",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "32,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-2BC1",
          "quantity": 208,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16640,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "208",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "208",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "16,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(37-47)-BR01 to DB-T2-(37-47)-3BA1",
          "quantity": 273,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21840,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "273",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "273",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "21,840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-1BA1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "42",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-1BB1",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "27",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-2BA1",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "45",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-2BB1",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,120.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/324-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-2BC1",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/R/25",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/325",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 132880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/325-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-BR01 to DB-T2-48-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-BR01 to DB-T2-48-3BA1",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 16999
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "24",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-LL01 to DB-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-LL01 to DB-T2-48-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1040,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17001
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "13",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-LL01 to DB-T2-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-LL01 to DB-T2-50-LL01",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17003
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "21",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-LL01 to DB-T2-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-LL01 to DB-T2-53-LL01",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17005
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "35",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-48-LL01 to DB-T2-56-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-48-LL01 to DB-T2-56-LL01",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "48",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-3BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-3BC1",
          "quantity": 166,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13280,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "166",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "166",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,280.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-58-BR01 to DB-T2-58-6B2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-58-BR01 to DB-T2-58-6B2",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3440,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,440.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T2-59-LL01 to DB-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T2-59-LL01 to DB-T2-59-LL01",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-06-LL01",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "27",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-09-LL01",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "37",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-12-LL01",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "48",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-15-LL01",
          "quantity": 58,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "58",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,640.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-18-LL01",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "69",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-21-LL01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "79",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-24-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "90",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-03-LL01 to DB-T3-27-LL01",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BA1",
          "quantity": 316,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25280,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "316",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "316",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "25,280.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BB1",
          "quantity": 216,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17280,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "216",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "216",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,280.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/325-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BC1",
          "quantity": 261,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 20880,
          "amount_state": "number",
          "printed_page": "2/R/26",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17035
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "261",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "261",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "20,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/326",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 368400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/326-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-1BC2",
          "quantity": 261,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 20880,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17049
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "261",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "261",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "20,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BA1",
          "quantity": 240,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19200,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "240",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "240",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "19,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BA2",
          "quantity": 339,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 27120,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "339",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "339",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,120.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BB1",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "300",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "24,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-2BC1",
          "quantity": 150,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "150",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "150",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(04-11)-BR01 to DB-T3-(04-11)-3BA1",
          "quantity": 199,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15920,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "199",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "199",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BA1",
          "quantity": 472,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37760,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "472",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "472",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "37,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BB1",
          "quantity": 323,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25840,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "323",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "323",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "25,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BC1",
          "quantity": 390,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31200,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "390",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "390",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-1BC2",
          "quantity": 391,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31280,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "391",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "391",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,280.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BA1",
          "quantity": 359,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28720,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "359",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "359",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "28,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BA2",
          "quantity": 508,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 40640,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "508",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "508",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "40,640.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BB1",
          "quantity": 449,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35920,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "449",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "35,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/326-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-2BC1",
          "quantity": 224,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17920,
          "amount_state": "number",
          "printed_page": "2/R/27",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "224",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/327",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 153440,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/327-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(12-23)-BR01 to DB-T3-(12-23)-3BA1",
          "quantity": 298,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23840,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "298",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "298",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "23,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BA1",
          "quantity": 198,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15840,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "198",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "198",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BB1",
          "quantity": 136,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10880,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "136",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BC1",
          "quantity": 164,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13120,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "164",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,120.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-1BC2",
          "quantity": 164,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 13120,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "164",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,120.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BA1",
          "quantity": 151,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12080,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "151",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "151",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BA2",
          "quantity": 213,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17040,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "213",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "213",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BB1",
          "quantity": 188,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15040,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "188",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "188",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-2BC1",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7600,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "95",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(24-28)-BR01 to DB-T3-(24-28)-3BA1",
          "quantity": 125,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "125",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "125",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-BR01 to DB-T3-29-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-BR01 to DB-T3-29-2BB1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "37",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-BR01 to DB-T3-29-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-BR01 to DB-T3-29-2BC1",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-BR01 to DB-T3-29-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-BR01 to DB-T3-29-3BA1",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1840,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "23",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-32-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-35-LL01",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/327-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-38-LL01",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3680,
          "amount_state": "number",
          "printed_page": "2/R/28",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "46",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,680.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/328",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 202720,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/328-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-41-LL01",
          "quantity": 57,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17144
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "57",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,560.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-44-LL01",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5360,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17146
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "67",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-47-LL01",
          "quantity": 78,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6240,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17148
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "78",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-50-LL01",
          "quantity": 88,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7040,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17150
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "88",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "88",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-53-LL01",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8240,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17152
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-54-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-54-LL01",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8720,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17154
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-54-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-54-LL01",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8720,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17156
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-56-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-29-LL01 to DB-T3-56-LL01",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8720,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17158
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BA1",
          "quantity": 197,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15760,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17160
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "197",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BB1",
          "quantity": 136,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 10880,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17162
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "136",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BC1",
          "quantity": 162,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12960,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17164
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "162",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "162",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-1BC2",
          "quantity": 162,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12960,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17166
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "162",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "162",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BA1",
          "quantity": 149,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 11920,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17168
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "149",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "149",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "11,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BA2",
          "quantity": 211,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16880,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17170
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "211",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "211",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "16,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BB1",
          "quantity": 187,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 14960,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17172
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "187",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "187",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "14,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-2BC1",
          "quantity": 93,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7440,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17174
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "93",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,440.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(31-35)-BR01 to DB-T3-(31-35)-3BA1",
          "quantity": 124,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 9920,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17176
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "124",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/328-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BA1",
          "quantity": 393,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31440,
          "amount_state": "number",
          "printed_page": "2/R/29",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17178
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "393",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "393",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,440.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/329",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 359840,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/329-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BB1",
          "quantity": 271,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21680,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "271",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "271",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,680.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BC1",
          "quantity": 324,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25920,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "324",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "324",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "25,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-1BC2",
          "quantity": 324,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25920,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "324",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "324",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "25,920.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BA1",
          "quantity": 297,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23760,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "297",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "297",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "23,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BA2",
          "quantity": 422,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 33760,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "422",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "422",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "33,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BB1",
          "quantity": 373,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29840,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "373",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "373",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "29,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-2BC1",
          "quantity": 185,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 14800,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "185",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "185",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "14,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(36-45)-BR01 to DB-T3-(36-45)-3BA1",
          "quantity": 247,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19760,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "247",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "247",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "19,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-55)-BR01 to DB-T3-(46-55)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-55)-BR01 to DB-T3-(46-55)-1BA1",
          "quantity": 397,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31760,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "397",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "397",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-55)-BR01 to DB-T3-(46-55)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-55)-BR01 to DB-T3-(46-55)-1BB1",
          "quantity": 275,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 22000,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "275",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "275",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "22,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-1BC1",
          "quantity": 328,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26240,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "328",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-1BC2",
          "quantity": 328,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26240,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "328",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "328",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BA1",
          "quantity": 301,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24080,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "301",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "301",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "24,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/329-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BA2",
          "quantity": 426,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 34080,
          "amount_state": "number",
          "printed_page": "2/R/30",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "426",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "426",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "34,080.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/330",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 133760,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/330-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BB1",
          "quantity": 377,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 30160,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "377",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "377",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "30,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/330-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-2BC1",
          "quantity": 189,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 15120,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "189",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "189",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,120.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/330-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-(46-53)-BR01 to DB-T3-(46-53)-3BA1",
          "quantity": 202,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16160,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "202",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "202",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "16,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/330-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-56-BR01 to DB-T3-56-6B1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-56-BR01 to DB-T3-56-6B1",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/330-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T3-56-BR01 to DB-T3-56-6B2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T3-56-BR01 to DB-T3-56-6B2",
          "quantity": 55,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "55",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/330-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-06-LL01",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "27",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,160.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/330-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-09-LL01",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,960.00",
            "[S]": "TRUE",
            "[T]": "2960"
          }
        },
        {
          "id": "2 - Main/330-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-12-LL01",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,840.00",
            "[S]": "TRUE",
            "[T]": "3840"
          }
        },
        {
          "id": "2 - Main/330-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-15-LL01",
          "quantity": 58,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17252
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "58",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,640.00",
            "[S]": "TRUE",
            "[T]": "4640"
          }
        },
        {
          "id": "2 - Main/330-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-18-LL01",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17254
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "69",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,520.00",
            "[S]": "TRUE",
            "[T]": "5520"
          }
        },
        {
          "id": "2 - Main/330-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-21-LL01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17256
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "79",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,320.00",
            "[S]": "TRUE",
            "[T]": "6320"
          }
        },
        {
          "id": "2 - Main/330-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-24-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17258
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "90",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,200.00",
            "[S]": "TRUE",
            "[T]": "7200"
          }
        },
        {
          "id": "2 - Main/330-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-03-LL01 to DB-T4-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-03-LL01 to DB-T4-27-LL01",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17260
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,000.00",
            "[S]": "TRUE",
            "[T]": "8000"
          }
        },
        {
          "id": "2 - Main/330-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BA1",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6320,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17262
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "79",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,320.00",
            "[S]": "TRUE",
            "[T]": "6320"
          }
        },
        {
          "id": "2 - Main/330-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BB1",
          "quantity": 55,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17264
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "55",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,400.00",
            "[S]": "TRUE",
            "[T]": "4400"
          }
        },
        {
          "id": "2 - Main/330-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BC1",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5360,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17266
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "67",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,360.00",
            "[S]": "TRUE",
            "[T]": "5360"
          }
        },
        {
          "id": "2 - Main/330-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-1BC2",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5360,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17268
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "67",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,360.00",
            "[S]": "TRUE",
            "[T]": "5360"
          }
        },
        {
          "id": "2 - Main/330-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BA1",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4880,
          "amount_state": "number",
          "printed_page": "2/R/31",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17270
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "61",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,880.00",
            "[S]": "TRUE",
            "[T]": "4880"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/331",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 329840,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/331-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BA2",
          "quantity": 86,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6880,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "86",
            "TOTAL QTY [I]": "86",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,880.00",
            "[S]": "TRUE",
            "[T]": "6880"
          }
        },
        {
          "id": "2 - Main/331-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BB1",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,000.00",
            "[S]": "TRUE",
            "[T]": "6000"
          }
        },
        {
          "id": "2 - Main/331-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-2BC1",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,040.00",
            "[S]": "TRUE",
            "[T]": "3040"
          }
        },
        {
          "id": "2 - Main/331-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(04-05)-BR01 to DB-T4-(04-05)-3BA1",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "50",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,000.00",
            "[S]": "TRUE",
            "[T]": "4000"
          }
        },
        {
          "id": "2 - Main/331-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BA1",
          "quantity": 472,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37760,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "472",
            "TOTAL QTY [I]": "472",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "37,760.00",
            "[S]": "TRUE",
            "[T]": "37760"
          }
        },
        {
          "id": "2 - Main/331-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BB1",
          "quantity": 327,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26160,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "327",
            "TOTAL QTY [I]": "327",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "26,160.00",
            "[S]": "TRUE",
            "[T]": "26160"
          }
        },
        {
          "id": "2 - Main/331-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BC1",
          "quantity": 398,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31840,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "398",
            "TOTAL QTY [I]": "398",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,840.00",
            "[S]": "TRUE",
            "[T]": "31840"
          }
        },
        {
          "id": "2 - Main/331-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-1BC2",
          "quantity": 396,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 31680,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "396",
            "TOTAL QTY [I]": "396",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,680.00",
            "[S]": "TRUE",
            "[T]": "31680"
          }
        },
        {
          "id": "2 - Main/331-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BA1",
          "quantity": 362,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 28960,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "362",
            "TOTAL QTY [I]": "362",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,960.00",
            "[S]": "TRUE",
            "[T]": "28960"
          }
        },
        {
          "id": "2 - Main/331-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BA2",
          "quantity": 512,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 40960,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17301
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "512",
            "TOTAL QTY [I]": "512",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "40,960.00",
            "[S]": "TRUE",
            "[T]": "40960"
          }
        },
        {
          "id": "2 - Main/331-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BB1",
          "quantity": 448,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 35840,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17303
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "448",
            "TOTAL QTY [I]": "448",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "35,840.00",
            "[S]": "TRUE",
            "[T]": "35840"
          }
        },
        {
          "id": "2 - Main/331-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-2BC1",
          "quantity": 226,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 18080,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "226",
            "TOTAL QTY [I]": "226",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "18,080.00",
            "[S]": "TRUE",
            "[T]": "18080"
          }
        },
        {
          "id": "2 - Main/331-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(06-17)-BR01 to DB-T4-(06-17)-3BA1",
          "quantity": 298,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 23840,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "298",
            "TOTAL QTY [I]": "298",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "23,840.00",
            "[S]": "TRUE",
            "[T]": "23840"
          }
        },
        {
          "id": "2 - Main/331-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BA1",
          "quantity": 435,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 34800,
          "amount_state": "number",
          "printed_page": "2/R/32",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "435",
            "TOTAL QTY [I]": "435",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "34,800.00",
            "[S]": "TRUE",
            "[T]": "34800"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/332",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 250400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/332-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BB1",
          "quantity": 301,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24080,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "301",
            "TOTAL QTY [I]": "301",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "24,080.00",
            "[S]": "TRUE",
            "[T]": "24080"
          }
        },
        {
          "id": "2 - Main/332-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BC1",
          "quantity": 366,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29280,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "366",
            "TOTAL QTY [I]": "366",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,280.00",
            "[S]": "TRUE",
            "[T]": "29280"
          }
        },
        {
          "id": "2 - Main/332-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-1BC2",
          "quantity": 364,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29120,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "364",
            "TOTAL QTY [I]": "364",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,120.00",
            "[S]": "TRUE",
            "[T]": "29120"
          }
        },
        {
          "id": "2 - Main/332-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BA1",
          "quantity": 333,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26640,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17332
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "333",
            "TOTAL QTY [I]": "333",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "26,640.00",
            "[S]": "TRUE",
            "[T]": "26640"
          }
        },
        {
          "id": "2 - Main/332-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BA2",
          "quantity": 471,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37680,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17334
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "471",
            "TOTAL QTY [I]": "471",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "37,680.00",
            "[S]": "TRUE",
            "[T]": "37680"
          }
        },
        {
          "id": "2 - Main/332-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BB1",
          "quantity": 413,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 33040,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "413",
            "TOTAL QTY [I]": "413",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "33,040.00",
            "[S]": "TRUE",
            "[T]": "33040"
          }
        },
        {
          "id": "2 - Main/332-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-2BC1",
          "quantity": 209,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16720,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17338
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "209",
            "TOTAL QTY [I]": "209",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "16,720.00",
            "[S]": "TRUE",
            "[T]": "16720"
          }
        },
        {
          "id": "2 - Main/332-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(18-28)-BR01 to DB-T4-(18-28)-3BA1",
          "quantity": 274,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21920,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17340
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "274",
            "TOTAL QTY [I]": "274",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,920.00",
            "[S]": "TRUE",
            "[T]": "21920"
          }
        },
        {
          "id": "2 - Main/332-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-BR01 to DB-T4-29-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-BR01 to DB-T4-29-2BB1",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2960,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17342
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,960.00",
            "[S]": "TRUE",
            "[T]": "2960"
          }
        },
        {
          "id": "2 - Main/332-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-BR01 to DB-T4-29-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-BR01 to DB-T4-29-2BC1",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,520.00",
            "[S]": "TRUE",
            "[T]": "1520"
          }
        },
        {
          "id": "2 - Main/332-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-BR01 to DB-T4-29-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-BR01 to DB-T4-29-3BA1",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1760,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,760.00",
            "[S]": "TRUE",
            "[T]": "1760"
          }
        },
        {
          "id": "2 - Main/332-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-29-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17348
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/332-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-32-LL01",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "27",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,160.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/332-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-35-LL01",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17352
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,040.00",
            "[S]": "TRUE",
            "[T]": "3040"
          }
        },
        {
          "id": "2 - Main/332-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-38-LL01",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17354
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,840.00",
            "[S]": "TRUE",
            "[T]": "3840"
          }
        },
        {
          "id": "2 - Main/332-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-41-LL01",
          "quantity": 59,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 4720,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17356
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "59",
            "TOTAL QTY [I]": "59",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,720.00",
            "[S]": "TRUE",
            "[T]": "4720"
          }
        },
        {
          "id": "2 - Main/332-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-44-LL01",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 5520,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "69",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,520.00",
            "[S]": "TRUE",
            "[T]": "5520"
          }
        },
        {
          "id": "2 - Main/332-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-47-LL01",
          "quantity": 80,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 6400,
          "amount_state": "number",
          "printed_page": "2/R/33",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "80",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,400.00",
            "[S]": "TRUE",
            "[T]": "6400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/333",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 318880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/333-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-50-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "90",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,200.00",
            "[S]": "TRUE",
            "[T]": "7200"
          }
        },
        {
          "id": "2 - Main/333-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-29-LL01 to DB-T4-53-LL01",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 8480,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "106",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,480.00",
            "[S]": "TRUE",
            "[T]": "8480"
          }
        },
        {
          "id": "2 - Main/333-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-30-BR01 to DB-T4-30-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-30-BR01 to DB-T4-30-2BB1",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "40",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,200.00",
            "[S]": "TRUE",
            "[T]": "3200"
          }
        },
        {
          "id": "2 - Main/333-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-30-BR01 to DB-T4-30-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-30-BR01 to DB-T4-30-2BC1",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1680,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,680.00",
            "[S]": "TRUE",
            "[T]": "1680"
          }
        },
        {
          "id": "2 - Main/333-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-30-BR01 to DB-T4-30-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-30-BR01 to DB-T4-30-3BA1",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "27",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,160.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/333-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BA1",
          "quantity": 437,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 34960,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "437",
            "TOTAL QTY [I]": "437",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "34,960.00",
            "[S]": "TRUE",
            "[T]": "34960"
          }
        },
        {
          "id": "2 - Main/333-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BB1",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "300",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "24,000.00",
            "[S]": "TRUE",
            "[T]": "24000"
          }
        },
        {
          "id": "2 - Main/333-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BC1",
          "quantity": 365,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29200,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "365",
            "TOTAL QTY [I]": "365",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,200.00",
            "[S]": "TRUE",
            "[T]": "29200"
          }
        },
        {
          "id": "2 - Main/333-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-1BC2",
          "quantity": 363,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 29040,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "363",
            "TOTAL QTY [I]": "363",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "29,040.00",
            "[S]": "TRUE",
            "[T]": "29040"
          }
        },
        {
          "id": "2 - Main/333-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BA1",
          "quantity": 332,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 26560,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "332",
            "TOTAL QTY [I]": "332",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "26,560.00",
            "[S]": "TRUE",
            "[T]": "26560"
          }
        },
        {
          "id": "2 - Main/333-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BA2",
          "quantity": 471,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 37680,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "471",
            "TOTAL QTY [I]": "471",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "37,680.00",
            "[S]": "TRUE",
            "[T]": "37680"
          }
        },
        {
          "id": "2 - Main/333-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BB1",
          "quantity": 412,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 32960,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "412",
            "TOTAL QTY [I]": "412",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "32,960.00",
            "[S]": "TRUE",
            "[T]": "32960"
          }
        },
        {
          "id": "2 - Main/333-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-2BC1",
          "quantity": 208,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16640,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "208",
            "TOTAL QTY [I]": "208",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "16,640.00",
            "[S]": "TRUE",
            "[T]": "16640"
          }
        },
        {
          "id": "2 - Main/333-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(31-41)-BR01 to DB-T4-(31-41)-3BA1",
          "quantity": 274,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21920,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "274",
            "TOTAL QTY [I]": "274",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,920.00",
            "[S]": "TRUE",
            "[T]": "21920"
          }
        },
        {
          "id": "2 - Main/333-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BA1",
          "quantity": 320,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 25600,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "320",
            "TOTAL QTY [I]": "320",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "25,600.00",
            "[S]": "TRUE",
            "[T]": "25600"
          }
        },
        {
          "id": "2 - Main/333-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BB1",
          "quantity": 220,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 17600,
          "amount_state": "number",
          "printed_page": "2/R/34",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "220",
            "TOTAL QTY [I]": "220",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,600.00",
            "[S]": "TRUE",
            "[T]": "17600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/334",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 190810,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/334-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BC1",
          "quantity": 267,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21360,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17423
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "267",
            "TOTAL QTY [I]": "267",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,360.00",
            "[S]": "TRUE",
            "[T]": "21360"
          }
        },
        {
          "id": "2 - Main/334-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-1BC2",
          "quantity": 266,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 21280,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "266",
            "TOTAL QTY [I]": "266",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,280.00",
            "[S]": "TRUE",
            "[T]": "21280"
          }
        },
        {
          "id": "2 - Main/334-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BA1",
          "quantity": 243,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19440,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "243",
            "TOTAL QTY [I]": "243",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "19,440.00",
            "[S]": "TRUE",
            "[T]": "19440"
          }
        },
        {
          "id": "2 - Main/334-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BA2",
          "quantity": 344,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 27520,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "344",
            "TOTAL QTY [I]": "344",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,520.00",
            "[S]": "TRUE",
            "[T]": "27520"
          }
        },
        {
          "id": "2 - Main/334-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BB1",
          "quantity": 301,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 24080,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "301",
            "TOTAL QTY [I]": "301",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "24,080.00",
            "[S]": "TRUE",
            "[T]": "24080"
          }
        },
        {
          "id": "2 - Main/334-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-2BC1",
          "quantity": 153,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 12240,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "153",
            "TOTAL QTY [I]": "153",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,240.00",
            "[S]": "TRUE",
            "[T]": "12240"
          }
        },
        {
          "id": "2 - Main/334-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-3BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-(42-49)-BR01 to DB-T4-(42-49)-3BA1",
          "quantity": 200,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 16000,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "200",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "16,000.00",
            "[S]": "TRUE",
            "[T]": "16000"
          }
        },
        {
          "id": "2 - Main/334-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-54-BR01 to DB-T4-54-6B1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-54-BR01 to DB-T4-54-6B1",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "960.00",
            "[S]": "TRUE",
            "[T]": "960"
          }
        },
        {
          "id": "2 - Main/334-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-54-BR01 to DB-T4-54-6B2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-54-BR01 to DB-T4-54-6B2",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 3440,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,440.00",
            "[S]": "TRUE",
            "[T]": "3440"
          }
        },
        {
          "id": "2 - Main/334-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC"
          ],
          "own_description": "From SMDB-T4-55-LL01 to DB-T4-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 10mm² XLPE/SWA/LSOH + 1C x 10mm² ECC — From SMDB-T4-55-LL01 to DB-T4-55-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17441
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "960.00",
            "[S]": "TRUE",
            "[T]": "960"
          }
        },
        {
          "id": "2 - Main/334-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 12mm² XLPE/SWA/LSOH + 1C x 12mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to DB-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 12mm² XLPE/SWA/LSOH + 1C x 12mm² ECC — From SMDB-T4-29-LL01 to DB-T4-29-LL01",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 2320,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "29",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,320.00",
            "[S]": "TRUE",
            "[T]": "2320"
          }
        },
        {
          "id": "2 - Main/334-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B1-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B1-EV1)",
          "quantity": 83,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 10790,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17449
          },
          "extra_columns": {
            "Basement [C]": "83",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "10,790.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/334-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B1-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B1-EV2)",
          "quantity": 86,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 11180,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17451
          },
          "extra_columns": {
            "Basement [C]": "86",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "86",
            "BASEMENTS [M]": "11,180.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/334-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B1-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B1-EV1)",
          "quantity": 63,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8190,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17453
          },
          "extra_columns": {
            "Basement [C]": "63",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "8,190.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/334-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B1-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B1-EV2)",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 11050,
          "amount_state": "number",
          "printed_page": "2/R/35",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17455
          },
          "extra_columns": {
            "Basement [C]": "85",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "11,050.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/335",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 147810,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/335-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B1-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B1-EV1)",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 14560,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17471
          },
          "extra_columns": {
            "Basement [C]": "112",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "14,560.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B1-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B1-EV2)",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 14560,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17473
          },
          "extra_columns": {
            "Basement [C]": "112",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "14,560.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B1-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B1-EV1)",
          "quantity": 49,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 6370,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17475
          },
          "extra_columns": {
            "Basement [C]": "49",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "6,370.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B1-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B1-EV2)",
          "quantity": 55,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7150,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17477
          },
          "extra_columns": {
            "Basement [C]": "55",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "7,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B2-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B2-EV1)",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 11960,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17479
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "11,960.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B2-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T1-B2-EV2)",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 12350,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17481
          },
          "extra_columns": {
            "Basement [C]": "95",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "12,350.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B2-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B2-EV1)",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9490,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17483
          },
          "extra_columns": {
            "Basement [C]": "73",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "9,490.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B2-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV1 to 40A TP isolator for EV charger (ISO-T3-B2-EV2)",
          "quantity": 96,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 12480,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17485
          },
          "extra_columns": {
            "Basement [C]": "96",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "12,480.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B2-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B2-EV1)",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 12350,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17487
          },
          "extra_columns": {
            "Basement [C]": "95",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "12,350.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B2-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV1 to 40A TP isolator for EV charger (ISO-T2-B2-EV2)",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13780,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17489
          },
          "extra_columns": {
            "Basement [C]": "106",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "13,780.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B2-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B2-EV1)",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 6890,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17491
          },
          "extra_columns": {
            "Basement [C]": "53",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "6,890.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B2-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP isolator for EV charger (ISO-T4-B2-EV2)",
          "quantity": 60,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17493
          },
          "extra_columns": {
            "Basement [C]": "60",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "7,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 63A TP isolator for GSM EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-GF-LV-01 to 63A TP isolator for GSM EQUIPMENT-1",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8970,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "69",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,970.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/335-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 63A TP isolator for GSM EQUIPMENT-2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-GF-LV-01 to 63A TP isolator for GSM EQUIPMENT-2",
          "quantity": 70,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9100,
          "amount_state": "number",
          "printed_page": "2/R/36",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "70",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "70",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/336",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 119170,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/336-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 63A TP isolator for ISO-T4-GSM-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-GF-LV03 to 63A TP isolator for ISO-T4-GSM-01",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 11960,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17510
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "92",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 63A TP isolator for ISO-T4-GSM-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-GF-LV03 to 63A TP isolator for ISO-T4-GSM-02",
          "quantity": 94,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 12220,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17512
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "94",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-GF-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-GF-EV1)",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13000,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17514
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-GF-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-GF-EV2)",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 10270,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "79",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-GF-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-GF-EV1)",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7930,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-GF-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-GF-EV2)",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 10270,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "79",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to 40A TP isolator for signage (ISO-T1-GF-SIGNAGE)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-LV01 to 40A TP isolator for signage (ISO-T1-GF-SIGNAGE)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17522
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/336-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-LV01 to 40A TP isolator for signage (ISO-T3-GF-SIGNAGE)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-LV01 to 40A TP isolator for signage (ISO-T3-GF-SIGNAGE)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 7000,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17524
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/336-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-GF-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-GF-EV1)",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13130,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "101",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-GF-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-GF-EV2)",
          "quantity": 105,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13650,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "105",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "105",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP weatherproof isolator for EV charger (ISO-T4-GF-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP weatherproof isolator for EV charger (ISO-T4-GF-EV1)",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5720,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/336-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV1 to 40A TP weatherproof isolator for EV charger (ISO-T4-GF-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV1 to 40A TP weatherproof isolator for EV charger (ISO-T4-GF-EV2)",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7020,
          "amount_state": "number",
          "printed_page": "2/R/37",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "54",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/337",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 203060,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/337-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-LL01 to 40A TP isolator for ODU-GF-DX",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-LL01 to 40A TP isolator for ODU-GF-DX",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13130,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "101",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,130.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-01-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-01-EV1)",
          "quantity": 123,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 15990,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17550
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "123",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "123",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-01-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-01-EV2)",
          "quantity": 131,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17030,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17552
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "131",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-02-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-02-EV1)",
          "quantity": 145,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 18850,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17554
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "145",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "145",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-02-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T2-02-EV2)",
          "quantity": 151,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 19630,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "151",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "151",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-01-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-01-EV1)",
          "quantity": 176,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 22880,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "176",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "176",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-01-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-01-EV2)",
          "quantity": 179,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 23270,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-01-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-01-EV1)",
          "quantity": 138,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17940,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "138",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "138",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-01-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-01-EV2)",
          "quantity": 136,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17680,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "136",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-01-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-01-EV1)",
          "quantity": 145,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 18850,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17566
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "145",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "145",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/337-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-01-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-01-EV2)",
          "quantity": 137,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17810,
          "amount_state": "number",
          "printed_page": "2/R/38",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17568
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "137",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "137",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,810.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/338",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 194210,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/338-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-02-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-02-EV1)",
          "quantity": 182,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 23660,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17584
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "182",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "182",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-02-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T1-02-EV2)",
          "quantity": 182,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 23660,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17586
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "182",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "182",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-02-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-02-EV1)",
          "quantity": 161,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 20930,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17588
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "161",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "161",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-02-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T3-02-EV2)",
          "quantity": 156,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 20280,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17590
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "156",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "156",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-02-EV1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-02-EV1)",
          "quantity": 154,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 20020,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17592
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "154",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "154",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,020.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-02-EV2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-GF-EV2 to 40A TP weatherproof isolator for EV charger (ISO-T4-02-EV2)",
          "quantity": 147,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 19110,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17594
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "147",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "147",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,110.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-LL01 to DB-T4-02-GYM",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-02-LL01 to DB-T4-02-GYM",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 10000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17596
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/338-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "quantity": 117,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 15210,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17598
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "117",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,210.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15210"
          }
        },
        {
          "id": "2 - Main/338-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "quantity": 131,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17030,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17600
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "131",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "131",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "17,030.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-17030"
          }
        },
        {
          "id": "2 - Main/338-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17602
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "30",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 4160,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17604
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,160.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7930,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17606
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "61",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,930.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/338-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8320,
          "amount_state": "number",
          "printed_page": "2/R/39",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17608
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "64",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/339",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 150930,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/339-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13390,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17622
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "103",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,390.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "quantity": 107,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13910,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17624
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "107",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,910.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "quantity": 41,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5330,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17626
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "41",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,330.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5720,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17628
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,720.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9490,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17630
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,490.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17632
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "75",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "quantity": 151,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 19630,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17634
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "151",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "151",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "19,630.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to 63A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T2-30-LL01 to 63A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "quantity": 164,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 21320,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17636
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "164",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "21,320.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 06 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 06 - GSM DU EQUIPMENT-1",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17638
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "30",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 07 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 07 - GSM DU EQUIPMENT-1",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 4420,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17640
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "34",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,420.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7930,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17642
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "61",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,930.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "quantity": 66,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8580,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17644
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "66",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,580.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13390,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17646
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "103",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,390.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/339-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 14170,
          "amount_state": "number",
          "printed_page": "2/R/40",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17648
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "14,170.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/340",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 127530,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/340-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 4940,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17662
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "38",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,940.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5590,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "43",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,590.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "quantity": 70,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9100,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "70",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9620,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "74",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,620.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 16900,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "130",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "16,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T3-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "quantity": 143,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 18590,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "143",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "143",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "18,590.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/340-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "30",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,900.00",
            "[S]": "TRUE",
            "[T]": "3900"
          }
        },
        {
          "id": "2 - Main/340-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 4160,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17676
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,160.00",
            "[S]": "TRUE",
            "[T]": "4160"
          }
        },
        {
          "id": "2 - Main/340-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 7930,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17678
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "61",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,930.00",
            "[S]": "TRUE",
            "[T]": "7930"
          }
        },
        {
          "id": "2 - Main/340-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8320,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17680
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "64",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,320.00",
            "[S]": "TRUE",
            "[T]": "8320"
          }
        },
        {
          "id": "2 - Main/340-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13390,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17682
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "103",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "13,390.00",
            "[S]": "TRUE",
            "[T]": "13390"
          }
        },
        {
          "id": "2 - Main/340-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "quantity": 107,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 13910,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "107",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "13,910.00",
            "[S]": "TRUE",
            "[T]": "13910"
          }
        },
        {
          "id": "2 - Main/340-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5460,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,460.00",
            "[S]": "TRUE",
            "[T]": "5460"
          }
        },
        {
          "id": "2 - Main/340-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5720,
          "amount_state": "number",
          "printed_page": "2/R/41",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,720.00",
            "[S]": "TRUE",
            "[T]": "5720"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/341",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 197180,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/341-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9620,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "74",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,620.00",
            "[S]": "TRUE",
            "[T]": "9620"
          }
        },
        {
          "id": "2 - Main/341-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17704
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,750.00",
            "[S]": "TRUE",
            "[T]": "9750"
          }
        },
        {
          "id": "2 - Main/341-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-01-ROOF",
          "quantity": 136,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 17680,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17706
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "136",
            "TOTAL QTY [I]": "136",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "17,680.00",
            "[S]": "TRUE",
            "[T]": "17680"
          }
        },
        {
          "id": "2 - Main/341-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T4-30-LL01 to 40A TP weatherproof isolator for ISO-BMU-02-ROOF",
          "quantity": 150,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 19500,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17708
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "150",
            "TOTAL QTY [I]": "150",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "19,500.00",
            "[S]": "TRUE",
            "[T]": "19500"
          }
        },
        {
          "id": "2 - Main/341-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T1-GF-LL06 to DB-T1&T3-GF-SS01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From LV-T1-GF-LL06 to DB-T1&T3-GF-SS01",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 3900,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17710
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-03-LL01 to DB-T1-21-LL01",
          "quantity": 78,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 10140,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17712
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "78",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,140.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10140"
          }
        },
        {
          "id": "2 - Main/341-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-03-LL01 to DB-T1-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-03-LL01 to DB-T1-24-LL01",
          "quantity": 89,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 11570,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17714
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "89",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "89",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,570.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-11570"
          }
        },
        {
          "id": "2 - Main/341-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-29-LL01 to DB-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-29-LL01 to DB-T1-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 1430,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17716
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,430.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1430"
          }
        },
        {
          "id": "2 - Main/341-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-56-BR01 to 100A TP Isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-56-BR01 to 100A TP Isolator",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 5720,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17718
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,720.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-03-LL01 to DB-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-03-LL01 to DB-T3-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 1560,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17720
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-29-LL01 to DB-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-29-LL01 to DB-T3-29-LL01",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 1430,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "11",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,430.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-LL01 to DB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-02-LL01 to DB-T4-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 1560,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-02-LL01 to DB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 16mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-02-LL01 to DB-T4-03-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 1560,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to SMDB-T2-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From LV-T2-GF-LL03 to SMDB-T2-B1-LL01",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 10240,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17730
          },
          "extra_columns": {
            "Basement [C]": "64",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "10,240.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to SMDB-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From LV-T2-GF-LL03 to SMDB-T2-B2-LL01",
          "quantity": 77,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 12320,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17732
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "12,320.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-RET to DB-PHARMACY",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-RET to DB-PHARMACY",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 8160,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-GF-RET to DB-SALOON",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-GF-RET to DB-SALOON",
          "quantity": 58,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 9280,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "58",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/341-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 6 - GSM DU EQUIPMENT-1",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "24",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3840"
          }
        },
        {
          "id": "2 - Main/341-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 7 - GSM DU EQUIPMENT-1",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4480,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17740
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4480"
          }
        },
        {
          "id": "2 - Main/341-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 15 - GSM DU EQUIPMENT-1",
          "quantity": 55,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 8800,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "55",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "55",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8800"
          }
        },
        {
          "id": "2 - Main/341-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 16 - GSM DU EQUIPMENT-1",
          "quantity": 60,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 9600,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "60",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-9600"
          }
        },
        {
          "id": "2 - Main/341-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 27 - GSM DU EQUIPMENT-1",
          "quantity": 97,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 15520,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "97",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "97",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15520"
          }
        },
        {
          "id": "2 - Main/341-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to 63A TP isolator for LEVEL 28 - GSM DU EQUIPMENT-1",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 16480,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "103",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,480.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-16480"
          }
        },
        {
          "id": "2 - Main/341-Z",
          "item_code": "Z",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T1-29-CHWP to 80A TP isolator for CHWP-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T1-29-CHWP to 80A TP isolator for CHWP-1",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/42",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3040"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/342",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 159680,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/342-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T1-29-CHWP to 80A TP isolator for CHWP-2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T1-29-CHWP to 80A TP isolator for CHWP-2",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3200"
          }
        },
        {
          "id": "2 - Main/342-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T1-29-CHWP to 80A TP isolator for CHWP-3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T1-29-CHWP to 80A TP isolator for CHWP-3",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3520,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,520.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3520"
          }
        },
        {
          "id": "2 - Main/342-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 36 - GSM DU EQUIPMENT-1",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 6240,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "39",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6240"
          }
        },
        {
          "id": "2 - Main/342-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 37 - GSM DU EQUIPMENT-1",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 7040,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17766
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7040"
          }
        },
        {
          "id": "2 - Main/342-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 45 - GSM DU EQUIPMENT-1",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17768
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "71",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-11360"
          }
        },
        {
          "id": "2 - Main/342-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From ESMDB-T1-30-LL01 to 63A TP isolator for LEVEL 46 - GSM DU EQUIPMENT-1",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17770
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "75",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12000"
          }
        },
        {
          "id": "2 - Main/342-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-4BA1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-4BA1",
          "quantity": 144,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 23040,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17772
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "144",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "144",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-4BA2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-(49-53)-BR01 to DB-T2-(49-53)-4BA2",
          "quantity": 206,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 32960,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17774
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "206",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "32,960.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-(54-57)-BR01 to DB-T2-(54-57)-4BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-(54-57)-BR01 to DB-T2-(54-57)-4BB1",
          "quantity": 104,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 16640,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17776
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "104",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "16,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-(54-57)-BR01 to DB-T2-(54-57)-4BB2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-(54-57)-BR01 to DB-T2-(54-57)-4BB2",
          "quantity": 159,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 25440,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17778
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "159",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "159",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "25,440.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-58-BR01 to DB-T2-58-6B1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-58-BR01 to DB-T2-58-6B1",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17780
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 20A TP isolator for CHWP-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T3-29-CHWP to 20A TP isolator for CHWP-1",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4160,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17782
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "26",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,160.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 80A TP isolator for CHWP-2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T3-29-CHWP to 80A TP isolator for CHWP-2",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4640,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17784
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "29",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,640.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From MCC-T3-29-CHWP to 80A TP isolator for CHWP-3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From MCC-T3-29-CHWP to 80A TP isolator for CHWP-3",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4960,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17786
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "31",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,960.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/342-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-57-LL01 to DB-T3-57-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-57-LL01 to DB-T3-57-LL01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2560,
          "amount_state": "number",
          "printed_page": "2/R/43",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17788
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,560.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/343",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 231420,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/343-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-(50-53)-BR01 to DB-T4-(50-53)-4BB1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-(50-53)-BR01 to DB-T4-(50-53)-4BB1",
          "quantity": 94,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 15040,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "94",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "15,040.00",
            "[S]": "TRUE",
            "[T]": "15040"
          }
        },
        {
          "id": "2 - Main/343-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-(50-53)-BR01 to DB-T4-(50-53)-4BB2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-(50-53)-BR01 to DB-T4-(50-53)-4BB2",
          "quantity": 149,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 23840,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "149",
            "TOTAL QTY [I]": "149",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "23,840.00",
            "[S]": "TRUE",
            "[T]": "23840"
          }
        },
        {
          "id": "2 - Main/343-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-57-LL01 to CP-T3-57-BCWP-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-57-LL01 to CP-T3-57-BCWP-01",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "20",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-57-LL01 to CP-T3-57-BCWP-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-57-LL01 to CP-T3-57-BCWP-02",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "20",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,200.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From CP-T3-57-FAHU to FAHU-57-SUP FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From CP-T3-57-FAHU to FAHU-57-SUP FAN",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 7040,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17817
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From CP-T3-57-FAHU to FAHU-57-EXT FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 25mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From CP-T3-57-FAHU to FAHU-57-EXT FAN",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 7040,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17819
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,040.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-B2-LL01 to MCC-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-B2-LL01 to MCC-T3-B2-LL01",
          "quantity": 182,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 40040,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17823
          },
          "extra_columns": {
            "Basement [C]": "182",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "182",
            "BASEMENTS [M]": "40,040.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-LL01 to 100A TP isolator for CP-01-FAHU-T1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-01-LL01 to 100A TP isolator for CP-01-FAHU-T1",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 11440,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-01-LL01 to 100A TP isolator for CP-01-FAHU-T3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-01-LL01 to 100A TP isolator for CP-01-FAHU-T3",
          "quantity": 253,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 55660,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "253",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "253",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "55,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T1-50-BR01 to 100A TP isolator, weatherproof for pool load",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T1-50-BR01 to 100A TP isolator, weatherproof for pool load",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17829
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,360.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8360"
          }
        },
        {
          "id": "2 - Main/343-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-29-LL01 to 100A TP isolator for CP-T2-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-29-LL01 to 100A TP isolator for CP-T2-29-FAHU",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 9680,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,680.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T2-58-BR01 to 100A TP weatherproof isolator for swimming pool",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T2-58-BR01 to 100A TP weatherproof isolator for swimming pool",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 11220,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "51",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "11,220.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T3-56-BR01 to 100A TP weatherproof isolator for pool load",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T3-56-BR01 to 100A TP weatherproof isolator for pool load",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 8580,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "39",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,580.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to 100A TP isolator for CP-T4-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-29-LL01 to 100A TP isolator for CP-T4-29-FAHU",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC"
          ],
          "own_description": "From SMDB-T4-54-BR01 to 100A TP isolator for pool load",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 35mm² XLPE/SWA/LSOH + 1C x 16mm² ECC — From SMDB-T4-54-BR01 to 100A TP isolator for pool load",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 11220,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "51",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "11,220.00",
            "[S]": "TRUE",
            "[T]": "11220"
          }
        },
        {
          "id": "2 - Main/343-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC"
          ],
          "own_description": "From SMDB-T1-B2-LL01 to MCC-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC — From SMDB-T1-B2-LL01 to MCC-T1-B2-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 3380,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17843
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "3,380.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/343-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC"
          ],
          "own_description": "From SMDB-T2-01-LL01 to 100A TP isolator for CP-T2-01-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC — From SMDB-T2-01-LL01 to 100A TP isolator for CP-T2-01-FAHU",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 12480,
          "amount_state": "number",
          "printed_page": "2/R/44",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/344",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 214625,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/344-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC"
          ],
          "own_description": "From SMDB-T4-01-LL01 to 80A TP isolator for CP-T4-01-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC — From SMDB-T4-01-LL01 to 80A TP isolator for CP-T4-01-FAHU",
          "quantity": 76,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 19760,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "76",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC"
          ],
          "own_description": "From SMDB-T1-51-LL01 to 125A TP isolator for CP-T1-51-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC — From SMDB-T1-51-LL01 to 125A TP isolator for CP-T1-51-FAHU",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 5200,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5200"
          }
        },
        {
          "id": "2 - Main/344-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC"
          ],
          "own_description": "From SMDB-T4-29-LL01 to 100A TP isolator for CP-T4-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 50mm² XLPE/SWA/LSOH + 1C x 25mm² ECC — From SMDB-T4-29-LL01 to 100A TP isolator for CP-T4-29-FAHU",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 260,
          "amount_aed": 11180,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "11,180.00",
            "[S]": "TRUE",
            "[T]": "11180"
          }
        },
        {
          "id": "2 - Main/344-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-1",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 12775,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17867
          },
          "extra_columns": {
            "Basement [C]": "35",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "12,775.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-2",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 11680,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17869
          },
          "extra_columns": {
            "Basement [C]": "32",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "11,680.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-3",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10585,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17871
          },
          "extra_columns": {
            "Basement [C]": "29",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "10,585.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-4",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP1 to 160A TP isolator for CHWP-4",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10220,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17873
          },
          "extra_columns": {
            "Basement [C]": "28",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "10,220.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-5",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-5",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10585,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17875
          },
          "extra_columns": {
            "Basement [C]": "29",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "10,585.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-6",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-6",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 9855,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17877
          },
          "extra_columns": {
            "Basement [C]": "27",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "9,855.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-7",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From MCC-T2-B1-CHWP2 to 160A TP isolator for CHWP-7",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 9125,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17879
          },
          "extra_columns": {
            "Basement [C]": "25",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "9,125.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL02 to SMDB-T2-GF-EV1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From LV-T2-GF-LL02 to SMDB-T2-GF-EV1",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 9855,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17881
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,855.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to SMDB-T2-GF-RET",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From LV-T2-GF-LL04 to SMDB-T2-GF-RET",
          "quantity": 163,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 59495,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "163",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "163",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "59,495.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From SMDB-T3-53-BR01 to 160A MCCB tap-off (SMDB-T3-56-BR01)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From SMDB-T3-53-BR01 to 160A MCCB tap-off (SMDB-T3-56-BR01)",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 5840,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17885
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (SMDB-T3-56-BR01) to SMDB-T3-56-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From 160A MCCB tap-off (SMDB-T3-56-BR01) to SMDB-T3-56-BR01",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10220,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "28",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,220.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/344-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From SMDB-T3-57-LL01 to 160A TP isolator for CP-T3-57-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From SMDB-T3-57-LL01 to 160A TP isolator for CP-T3-57-FAHU",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 18250,
          "amount_state": "number",
          "printed_page": "2/R/45",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17889
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "50",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "18,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/345",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 569495,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/345-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From SMDB-T4-53-BR01 to 160A MCCB tap-off (SMDB-T4-54-BR01)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From SMDB-T4-53-BR01 to 160A MCCB tap-off (SMDB-T4-54-BR01)",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 8030,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17904
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,030.00",
            "[S]": "TRUE",
            "[T]": "8030"
          }
        },
        {
          "id": "2 - Main/345-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off to SMDB-T4-54-BR01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From 160A MCCB tap-off to SMDB-T4-54-BR01",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 10220,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17906
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "28",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,220.00",
            "[S]": "TRUE",
            "[T]": "10220"
          }
        },
        {
          "id": "2 - Main/345-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC"
          ],
          "own_description": "From SMDB-T4-55-LL01 to 160A TP isolator for CP-T4-55-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 70mm² XLPE/SWA/LSOH + 1C x 35mm² ECC — From SMDB-T4-55-LL01 to 160A TP isolator for CP-T4-55-FAHU",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 365,
          "amount_aed": 6935,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,935.00",
            "[S]": "TRUE",
            "[T]": "6935"
          }
        },
        {
          "id": "2 - Main/345-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL03 to SMDB-T2-GF-CAFE1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From LV-T2-GF-LL03 to SMDB-T2-GF-CAFE1",
          "quantity": 77,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 34650,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17912
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T1-CA-005) to MCC-T1-29-CHWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From 160A MCCB tap-off (BB-T1-CA-005) to MCC-T1-29-CHWP",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 12600,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17914
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12600"
          }
        },
        {
          "id": "2 - Main/345-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From SMDB-T2-59-LL01 to 160A TP isolator for CP-T2-59-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From SMDB-T2-59-LL01 to 160A TP isolator for CP-T2-59-FAHU",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 8550,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17916
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "19",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,550.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From 160A MCCB tap-off (BB-T3-CA-006) to MCC-T3-29-CHWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From 160A MCCB tap-off (BB-T3-CA-006) to MCC-T3-29-CHWP",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 13950,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17918
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "31",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT1)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 12600,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17920
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "28",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT2)",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 11250,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17922
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "25",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "11,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-57-LIFT1 to 160A TP isolator for lift (ISO-T3-LIFT3)",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17924
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "35",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17926
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "38",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-57-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT5)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17928
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "38",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "17,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC"
          ],
          "own_description": "From ESMDB-T3-57-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 95mm² XLPE/SWA/LSOH + 1C x 50mm² ECC — From ESMDB-T3-57-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT6)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 16650,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17930
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "37",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "16,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to SMDB-T2-GF-CAFE2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From LV-T2-GF-LL04 to SMDB-T2-GF-CAFE2",
          "quantity": 179,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 127090,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17934
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "127,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to SMDB-T2-GF-CAFE3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From LV-T2-GF-LL04 to SMDB-T2-GF-CAFE3",
          "quantity": 183,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 129930,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17936
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "183",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "183",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "129,930.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From 200A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-02-SWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From 200A MCCB tap-off (BB-T4-CA-005) to SMDB-T4-02-SWP",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 58220,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17938
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "58,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/345-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT1)",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 22010,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17940
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "31",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "22,010.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-22010"
          }
        },
        {
          "id": "2 - Main/345-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT2)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 19880,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17942
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "19,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-19880"
          }
        },
        {
          "id": "2 - Main/345-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT3)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26980,
          "amount_state": "number",
          "printed_page": "2/R/46",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17944
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "38",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,980.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26980"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/346",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 227200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/346-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT4)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26270,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17954
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,270.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26270"
          }
        },
        {
          "id": "2 - Main/346-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT5)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26270,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17956
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,270.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26270"
          }
        },
        {
          "id": "2 - Main/346-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T1-51-LIFT to 125A TP isolator for lift (ISO-T1-LIFT6)",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 25560,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-25560"
          }
        },
        {
          "id": "2 - Main/346-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT1)",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 22010,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "31",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "22,010.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT2)",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 19880,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "28",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "19,880.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT3)",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 27690,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "27,690.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26980,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "38",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,980.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT5)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26270,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,270.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T2-59-LIFT to 125A TP isolator for lift (ISO-T2-LIFT6)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26270,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "37",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,270.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT1)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT2)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT1 to 125A TP isolator for lift (ISO-T3-LIFT3)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT4)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/346-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT5)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/47",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/347",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 542685,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/347-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T3-55-LIFT2 to 125A TP isolator for lift (ISO-T3-LIFT6)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17994
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/347-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From 250A MCCB tap-off (BB-T4-CA-005) to MCC-T4-29-CHWP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From 250A MCCB tap-off (BB-T4-CA-005) to MCC-T4-29-CHWP",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17996
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/347-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT1)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT1)",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 22720,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 17998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "22,720.00",
            "[S]": "TRUE",
            "[T]": "22720"
          }
        },
        {
          "id": "2 - Main/347-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT2)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT2)",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 20590,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "29",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "20,590.00",
            "[S]": "TRUE",
            "[T]": "20590"
          }
        },
        {
          "id": "2 - Main/347-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT3)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT3)",
          "quantity": 39,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 27690,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18002
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "39",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "27,690.00",
            "[S]": "TRUE",
            "[T]": "27690"
          }
        },
        {
          "id": "2 - Main/347-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT4)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT4)",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26980,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18004
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "26,980.00",
            "[S]": "TRUE",
            "[T]": "26980"
          }
        },
        {
          "id": "2 - Main/347-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT5)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT5)",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 26270,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18006
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "26,270.00",
            "[S]": "TRUE",
            "[T]": "26270"
          }
        },
        {
          "id": "2 - Main/347-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC"
          ],
          "own_description": "From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT6)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/LSOH + 1C x 70mm² ECC — From ESMDB-T4-55-LIFT to 125A TP isolator for lift (ISO-T4-LIFT6)",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 710,
          "amount_aed": 25560,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "36",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "25,560.00",
            "[S]": "TRUE",
            "[T]": "25560"
          }
        },
        {
          "id": "2 - Main/347-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/LSOH + 1C x 95mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to SMDB-T2-GF-C-STORE(SM)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/LSOH + 1C x 95mm² ECC — From LV-T2-GF-LL04 to SMDB-T2-GF-C-STORE(SM)",
          "quantity": 201,
          "unit": "m",
          "rate_aed": 875,
          "amount_aed": 175875,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18012
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "201",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "201",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "175,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/347-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 185mm² XLPE/SWA/LSOH + 2 x 1C x 95mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to MCC-T2-B1-CHWP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 185mm² XLPE/SWA/LSOH + 2 x 1C x 95mm² ECC — From LV-T2-GF-LL04 to MCC-T2-B1-CHWP1",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 1750,
          "amount_aed": 106750,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18016
          },
          "extra_columns": {
            "Basement [C]": "61",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "106,750.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/347-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 185mm² XLPE/SWA/LSOH + 2 x 1C x 95mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to MCC-T2-B1-CHWP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 185mm² XLPE/SWA/LSOH + 2 x 1C x 95mm² ECC — From LV-T2-GF-LL04 to MCC-T2-B1-CHWP2",
          "quantity": 63,
          "unit": "m",
          "rate_aed": 1750,
          "amount_aed": 110250,
          "amount_state": "number",
          "printed_page": "2/R/48",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18018
          },
          "extra_columns": {
            "Basement [C]": "63",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "110,250.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/348",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 40380,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/348-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T1-B2-LL01 to 20A TP isolator for CP-PB-06 (Lifting Station)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From ESMDB-T1-B2-LL01 to 20A TP isolator for CP-PB-06 (Lifting Station)",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 2025,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18038
          },
          "extra_columns": {
            "Basement [C]": "45",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "2,025.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-01 (Lifting Station)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-01 (Lifting Station)",
          "quantity": 66,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 2970,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18040
          },
          "extra_columns": {
            "Basement [C]": "66",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "2,970.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-02 (Lifting Station)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-02 (Lifting Station)",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 6345,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18042
          },
          "extra_columns": {
            "Basement [C]": "141",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "6,345.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-03 (Lifting Station) for Tower 2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From ESMDB-T2-B2-LL01 to 20A TP isolator for CP-PB-03 (Lifting Station) for Tower 2",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18044
          },
          "extra_columns": {
            "Basement [C]": "170",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "7,650.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From ESMDB-T3-B2-LL01 to 20A TP isolator for CP-PB-05 (Lifting Station) for Tower 3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From ESMDB-T3-B2-LL01 to 20A TP isolator for CP-PB-05 (Lifting Station) for Tower 3",
          "quantity": 78,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 3510,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18046
          },
          "extra_columns": {
            "Basement [C]": "78",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "3,510.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-01",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18048
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-02",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 1710,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,710.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC"
          ],
          "own_description": "From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 4mm² XLPE/SWA/FR + 1C x 4mm² ECC — From EMCC-T3-02-FAN1 to 20A TP isolator for T3-P2-FPEF-03",
          "quantity": 18,
          "unit": "m",
          "rate_aed": 45,
          "amount_aed": 810,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18052
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "810.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for central battery (ISO-T1-GF-CBS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for central battery (ISO-T1-GF-CBS)",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1980,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for central battery (ISO-T3-GF-CBS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for central battery (ISO-T3-GF-CBS)",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1980,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18058
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for CP-T1&3-LV1-FPMF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for CP-T1&3-LV1-FPMF",
          "quantity": 96,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18060
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "96",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for CP-T1&3-LV1-SPF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T1&3-GF-LV-01 to 32A TP isolator for CP-T1&3-LV1-SPF",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2880,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18062
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 32A TP isolator for central battery (ISO-T2-GF-CBS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T2-GF-LV-01 to 32A TP isolator for central battery (ISO-T2-GF-CBS)",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18064
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/348-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/49",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18066
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/349",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 30540,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/349-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1 (MAINTENANCE BYPASS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1 (MAINTENANCE BYPASS)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1 (MAINTENANCE BYPASS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T2-GF-LV-01 to 32A TP isolator for ISO-TF-GF-UPS1 (MAINTENANCE BYPASS)",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to 32A TP isolator for central battery (ISO-T4-GF-CBS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From ESMDB-T4-GF-LV03 to 32A TP isolator for central battery (ISO-T4-GF-CBS)",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-FPEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-FPEF",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3180,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18083
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "53",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,180.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3180"
          }
        },
        {
          "id": "2 - Main/349-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-FPMF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-FPMF",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,580.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2580"
          }
        },
        {
          "id": "2 - Main/349-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-MAF",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18087
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,580.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2580"
          }
        },
        {
          "id": "2 - Main/349-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-SEF-01",
          "quantity": 57,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3420,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18089
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "57",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,420.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3420"
          }
        },
        {
          "id": "2 - Main/349-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-SEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-30-FAN to 20A TP isolator for T1-30F-SEF-02",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 780,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18091
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "780.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-780"
          }
        },
        {
          "id": "2 - Main/349-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-51-FAN to 20A TP fire rated isolator for T1-51F-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-51-FAN to 20A TP fire rated isolator for T1-51F-MAF",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1560,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18093
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "26",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,560.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1560"
          }
        },
        {
          "id": "2 - Main/349-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T1-51-FAN to 20A TP fire rated isolator for T1-51F-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T1-51-FAN to 20A TP fire rated isolator for T1-51F-SEF-01",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18095
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2400"
          }
        },
        {
          "id": "2 - Main/349-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 20A TP isolator for T2-30-FPEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-30-FAN to 20A TP isolator for T2-30-FPEF",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3180,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18097
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,180.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 20A TP isolator for T2-30-FPMF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-30-FAN to 20A TP isolator for T2-30-FPMF",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18099
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 20A TP isolator for T2-30-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-30-FAN to 20A TP isolator for T2-30-MAF",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2640,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "44",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/349-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 20A TP isolator for T2-30-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-30-FAN to 20A TP isolator for T2-30-SEF-01",
          "quantity": 59,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3540,
          "amount_state": "number",
          "printed_page": "2/R/50",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "59",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "59",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,540.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/350",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 35940,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/350-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 20A TP isolator for T2-30-SEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-30-FAN to 20A TP isolator for T2-30-SEF-02",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18116
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "840.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-59-FAN to 20A TP fire rated isolator for T2-59-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-59-FAN to 20A TP fire rated isolator for T2-59-MAF",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18118
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "27",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,620.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T2-59-FAN to 20A TP fire rated isolator for T2-59-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T2-59-FAN to 20A TP fire rated isolator for T2-59-SEF-01",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18120
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 20A TP isolator for T3-30-FPEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-30-FAN to 20A TP isolator for T3-30-FPEF",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3060,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18122
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,060.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 20A TP isolator for T3-30-FPMF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-30-FAN to 20A TP isolator for T3-30-FPMF",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18124
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "43",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,580.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 20A TP isolator for T3-30-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-30-FAN to 20A TP isolator for T3-30-MAF",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2760,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18126
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "46",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 20A TP isolator for T3-30-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-30-FAN to 20A TP isolator for T3-30-SEF-01",
          "quantity": 56,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18128
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "56",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 20A TP isolator for T3-30-SEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-30-FAN to 20A TP isolator for T3-30-SEF-02",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18130
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-57-FAN to 20A TP fire rated isolator for T3-55-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-57-FAN to 20A TP fire rated isolator for T3-55-MAF",
          "quantity": 56,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18132
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "56",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,360.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T3-57-FAN to 20A TP fire rated isolator for T3-55-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T3-57-FAN to 20A TP fire rated isolator for T3-55-SEF-01",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18134
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "64",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/350-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 20A TP isolator for T4-30-FPEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-30-FAN to 20A TP isolator for T4-30-FPEF",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3120,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18136
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,120.00",
            "[S]": "TRUE",
            "[T]": "3120"
          }
        },
        {
          "id": "2 - Main/350-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 20A TP isolator for T4-30-FPMF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-30-FAN to 20A TP isolator for T4-30-FPMF",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18138
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,580.00",
            "[S]": "TRUE",
            "[T]": "2580"
          }
        },
        {
          "id": "2 - Main/350-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 20A TP isolator for T4-30-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-30-FAN to 20A TP isolator for T4-30-MAF",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18140
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,580.00",
            "[S]": "TRUE",
            "[T]": "2580"
          }
        },
        {
          "id": "2 - Main/350-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 20A TP isolator for T4-30-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-30-FAN to 20A TP isolator for T4-30-SEF-01",
          "quantity": 58,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 3480,
          "amount_state": "number",
          "printed_page": "2/R/51",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18142
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "58",
            "TOTAL QTY [I]": "58",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,480.00",
            "[S]": "TRUE",
            "[T]": "3480"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/351",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 71270,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/351-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 20A TP isolator for T4-30-SEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-30-FAN to 20A TP isolator for T4-30-SEF-02",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "14",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "840.00",
            "[S]": "TRUE",
            "[T]": "840"
          }
        },
        {
          "id": "2 - Main/351-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-55-FAN to 20A TP fire rated isolator for T4-55-MAF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-55-FAN to 20A TP fire rated isolator for T4-55-MAF",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,920.00",
            "[S]": "TRUE",
            "[T]": "1920"
          }
        },
        {
          "id": "2 - Main/351-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC"
          ],
          "own_description": "From EMCC-T4-55-FAN to 20A TP fire rated isolator for T4-55-SEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 6mm² XLPE/SWA/FR + 1C x 6mm² ECC — From EMCC-T4-55-FAN to 20A TP fire rated isolator for T4-55-SEF-01",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,580.00",
            "[S]": "TRUE",
            "[T]": "2580"
          }
        },
        {
          "id": "2 - Main/351-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-B2-LL01 to EDB-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-B2-LL01 to EDB-T1-B2-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1235,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18163
          },
          "extra_columns": {
            "Basement [C]": "13",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "1,235.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to EDB-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-B2-LL01 to EDB-T2-B2-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1330,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18165
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "1,330.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to EDB-T2-B2-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-B2-LL01 to EDB-T2-B2-LL02",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 13395,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18167
          },
          "extra_columns": {
            "Basement [C]": "141",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "13,395.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-B2-LL01 to EDB-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-B2-LL01 to EDB-T3-B2-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1330,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18169
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "1,330.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-B2-LL01 to EDB-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-B2-LL01 to EDB-T1-B1-LL01",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1995,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18171
          },
          "extra_columns": {
            "Basement [C]": "21",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "1,995.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to EDB-T2-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-B2-LL01 to EDB-T2-B1-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2375,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18173
          },
          "extra_columns": {
            "Basement [C]": "25",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "2,375.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-B2-LL01 to EDB-T2-B1-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-B2-LL01 to EDB-T2-B1-LL02",
          "quantity": 150,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 14250,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18175
          },
          "extra_columns": {
            "Basement [C]": "150",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "150",
            "BASEMENTS [M]": "14,250.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-B2-LL01 to EDB-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-B2-LL01 to EDB-T3-B1-LL01",
          "quantity": 103,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 9785,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18177
          },
          "extra_columns": {
            "Basement [C]": "103",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "103",
            "BASEMENTS [M]": "9,785.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMDB-T4-GF-LV03 to ESMDB-T4-B2-LL01",
          "quantity": 110,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 10450,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18179
          },
          "extra_columns": {
            "Basement [C]": "110",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "110",
            "BASEMENTS [M]": "10,450.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-B2-LL01 to EDB-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-B2-LL01 to EDB-T1-GF-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2090,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-B2-LL01 to EDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-B2-LL01 to EDB-T3-GF-LL01",
          "quantity": null,
          "unit": "m",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to EDB-T4-GF-LV03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-GF-LV03 to EDB-T4-GF-LV03",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1805,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,805.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From Generator Panel (GEN 2-GF-LV03) to 1500kVA Generator set",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From Generator Panel (GEN 2-GF-LV03) to 1500kVA Generator set",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3420,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/351-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From Generator Panel (GEN-T1&3-GF-LV01) to 1000kVA Generator set",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From Generator Panel (GEN-T1&3-GF-LV01) to 1000kVA Generator set",
          "quantity": 26,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2470,
          "amount_state": "number",
          "printed_page": "2/R/52",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,470.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/352",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 66880,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/352-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P1-LL01 to EDB-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P1-LL01 to EDB-T1-01-LL01",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1235,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18202
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,235.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-01-LL01 to EDB-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-01-LL01 to EDB-T2-01-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1330,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18204
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P1-LL01 to EDB-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P1-LL01 to EDB-T3-01-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1140,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18206
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,140.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-01-LL01 to EDB-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-01-LL01 to EDB-T4-01-LL01",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1140,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18208
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,140.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P1-LL01 to EDB-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P1-LL01 to EDB-T1-02-LL01",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2185,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18210
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,185.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-01-LL01 to EDB-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-01-LL01 to EDB-T2-02-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2375,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18212
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P1-LL01 to EDB-T3-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P1-LL01 to EDB-T3-02-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2375,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-03-LL01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1330,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-03-LL01",
          "quantity": 16,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-03-LL01",
          "quantity": 17,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1615,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18220
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,615.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-03-LL01",
          "quantity": 17,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1615,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,615.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-04-LL01",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1805,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18224
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,805.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1805"
          }
        },
        {
          "id": "2 - Main/352-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-07-LL01",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2755,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "29",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,755.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2755"
          }
        },
        {
          "id": "2 - Main/352-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-10-LL01",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3800,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3800"
          }
        },
        {
          "id": "2 - Main/352-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-13-LL01",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "50",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4750"
          }
        },
        {
          "id": "2 - Main/352-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-16-LL01",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5795,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "61",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,795.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5795"
          }
        },
        {
          "id": "2 - Main/352-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-19-LL01",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6745,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "71",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,745.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6745"
          }
        },
        {
          "id": "2 - Main/352-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-22-LL01",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7790,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "82",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,790.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7790"
          }
        },
        {
          "id": "2 - Main/352-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1 & 3-GF-LV-01 to EDB-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1 & 3-GF-LV-01 to EDB-T1-GF-LL01",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "50",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/352-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 32A TP isolator for T1-30F-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T1-30-FAN to 32A TP isolator for T1-30F-SPF-01",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4370,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,370.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4370"
          }
        },
        {
          "id": "2 - Main/352-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T1-30-FAN to 32A TP isolator for T1-30F-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T1-30-FAN to 32A TP isolator for T1-30F-SPF-02",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4370,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "46",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,370.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4370"
          }
        },
        {
          "id": "2 - Main/352-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-31-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2090,
          "amount_state": "number",
          "printed_page": "2/R/53",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,090.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2090"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/353",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 99845,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/353-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-34-LL01",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18257
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "32",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,040.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3040"
          }
        },
        {
          "id": "2 - Main/353-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-37-LL01",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4085,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "43",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,085.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4085"
          }
        },
        {
          "id": "2 - Main/353-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-40-LL01",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5035,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18261
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "53",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,035.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5035"
          }
        },
        {
          "id": "2 - Main/353-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-43-LL01",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6080,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18263
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "64",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,080.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-6080"
          }
        },
        {
          "id": "2 - Main/353-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-46-LL01",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7030,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "74",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,030.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7030"
          }
        },
        {
          "id": "2 - Main/353-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-49-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8550,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "90",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,550.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8550"
          }
        },
        {
          "id": "2 - Main/353-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T1-30-LL01 to EDB-T1-51-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T1-30-LL01 to EDB-T1-51-LL01",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 9500,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "100",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-9500"
          }
        },
        {
          "id": "2 - Main/353-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T1-51-FAN to 32A TP fire rated isolator for T1-51F-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T1-51-FAN to 32A TP fire rated isolator for T1-51F-SPF-01",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4275,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,275.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4275"
          }
        },
        {
          "id": "2 - Main/353-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T1-51-FAN to 32A TP fire rated isolator for T1-51F-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T1-51-FAN to 32A TP fire rated isolator for T1-51F-SPF-02",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2945,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "31",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,945.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2945"
          }
        },
        {
          "id": "2 - Main/353-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-04-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2090,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,090.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-07-LL01",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-10-LL01",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4085,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,085.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-13-LL01",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5035,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,035.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-16-LL01",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6080,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "64",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-19-LL01",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7030,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "74",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,030.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-22-LL01",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8075,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,075.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 32A TP isolator for T2-30-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T2-30-FAN to 32A TP isolator for T2-30-SPF-01",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4370,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "46",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,370.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T2-30-FAN to 32A TP isolator for T2-30-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T2-30-FAN to 32A TP isolator for T2-30-SPF-02",
          "quantity": 46,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4370,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "46",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,370.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-31-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2090,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,090.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/353-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-34-LL01",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3040,
          "amount_state": "number",
          "printed_page": "2/R/54",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,040.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/354",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 123595,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/354-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-37-LL01",
          "quantity": 43,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4085,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18308
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "43",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,085.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-40-LL01",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5035,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18310
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "53",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,035.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-43-LL01",
          "quantity": 64,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6080,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18312
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "64",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-46-LL01",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7030,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18314
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "74",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,030.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-48-LL01",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8075,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18316
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "85",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,075.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-49-LL01",
          "quantity": 88,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8360,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18318
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "88",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "88",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,360.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-52-LL01",
          "quantity": 100,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 9500,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18320
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "100",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-55-LL01",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 10640,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18322
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "112",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T2-30-LL01 to EDB-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T2-30-LL01 to EDB-T2-59-LL01",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 12350,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18324
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "130",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,350.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T2-59-FAN to 32A TP fire rated isolator for T2-59-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T2-59-FAN to 32A TP fire rated isolator for T2-59-SPF-01",
          "quantity": 60,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5700,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "60",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T2-59-FAN to 32A TP fire rated isolator for T2-59-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T2-59-FAN to 32A TP fire rated isolator for T2-59-SPF-02",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "48",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,560.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-04-LL01",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1900,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "20",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-07-LL01",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2850,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18332
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "30",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,850.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-10-LL01",
          "quantity": 41,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3895,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18334
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "41",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,895.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-13-LL01",
          "quantity": 51,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4845,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "51",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,845.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-16-LL01",
          "quantity": 62,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5890,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18338
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "62",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "62",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,890.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-19-LL01",
          "quantity": 72,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6840,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18340
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "72",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "72",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-22-LL01",
          "quantity": 83,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7885,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18342
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "83",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,885.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 32A TP isolator for T3-30-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T3-30-FAN to 32A TP isolator for T3-30-SPF-01",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4180,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,180.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/354-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T3-30-FAN to 32A TP isolator for T3-30-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T3-30-FAN to 32A TP isolator for T3-30-SPF-02",
          "quantity": 41,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3895,
          "amount_state": "number",
          "printed_page": "2/R/55",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "41",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,895.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/355",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 120460,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/355-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-31-LL01",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1995,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,995.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-34-LL01",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2945,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "31",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,945.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-37-LL01",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3990,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "42",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,990.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-40-LL01",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4940,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18364
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "52",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,940.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-43-LL01",
          "quantity": 63,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5985,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18366
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "63",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "5,985.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-46-LL01",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6935,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "73",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,935.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-49-LL01",
          "quantity": 84,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7980,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18370
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "84",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,980.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-52-LL01",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8550,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18372
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "90",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,550.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-55-LL01",
          "quantity": 113,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 10735,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18374
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "113",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,735.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T3-30-LL01 to EDB-T3-57-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T3-30-LL01 to EDB-T3-57-LL01",
          "quantity": 141,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 13395,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18376
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "141",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,395.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T3-57-FAN to 32A TP fire rated isolator for T3-55-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T3-57-FAN to 32A TP fire rated isolator for T3-55-SPF-01",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6555,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18378
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "69",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,555.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T3-57-FAN to 32A TP fire rated isolator for T3-55-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T3-57-FAN to 32A TP fire rated isolator for T3-55-SPF-02",
          "quantity": 78,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7410,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18380
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "78",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,410.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/355-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-04-LL01",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 1995,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18382
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,995.00",
            "[S]": "TRUE",
            "[T]": "1995"
          }
        },
        {
          "id": "2 - Main/355-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-07-LL01",
          "quantity": 31,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2945,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18384
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,945.00",
            "[S]": "TRUE",
            "[T]": "2945"
          }
        },
        {
          "id": "2 - Main/355-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-10-LL01",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3990,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18386
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,990.00",
            "[S]": "TRUE",
            "[T]": "3990"
          }
        },
        {
          "id": "2 - Main/355-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-13-LL01",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4940,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18388
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "52",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,940.00",
            "[S]": "TRUE",
            "[T]": "4940"
          }
        },
        {
          "id": "2 - Main/355-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-16-LL01",
          "quantity": 63,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5985,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18390
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "63",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,985.00",
            "[S]": "TRUE",
            "[T]": "5985"
          }
        },
        {
          "id": "2 - Main/355-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-19-LL01",
          "quantity": 73,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6935,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18392
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "73",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,935.00",
            "[S]": "TRUE",
            "[T]": "6935"
          }
        },
        {
          "id": "2 - Main/355-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-22-LL01",
          "quantity": 84,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7980,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18394
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "84",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,980.00",
            "[S]": "TRUE",
            "[T]": "7980"
          }
        },
        {
          "id": "2 - Main/355-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 32A TP isolator for T4-30-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T4-30-FAN to 32A TP isolator for T4-30-SPF-01",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4275,
          "amount_state": "number",
          "printed_page": "2/R/56",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18396
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,275.00",
            "[S]": "TRUE",
            "[T]": "4275"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/356",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 85950,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/356-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T4-30-FAN to 32A TP isolator for T4-30-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T4-30-FAN to 32A TP isolator for T4-30-SPF-02",
          "quantity": 45,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4275,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18410
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "45",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,275.00",
            "[S]": "TRUE",
            "[T]": "4275"
          }
        },
        {
          "id": "2 - Main/356-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-31-LL01",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 2185,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18412
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "23",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,185.00",
            "[S]": "TRUE",
            "[T]": "2185"
          }
        },
        {
          "id": "2 - Main/356-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-34-LL01",
          "quantity": 33,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 3135,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18414
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "33",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,135.00",
            "[S]": "TRUE",
            "[T]": "3135"
          }
        },
        {
          "id": "2 - Main/356-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-37-LL01",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4180,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18416
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,180.00",
            "[S]": "TRUE",
            "[T]": "4180"
          }
        },
        {
          "id": "2 - Main/356-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-40-LL01",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5130,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18418
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "54",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,130.00",
            "[S]": "TRUE",
            "[T]": "5130"
          }
        },
        {
          "id": "2 - Main/356-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-43-LL01",
          "quantity": 65,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 6175,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18420
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "65",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,175.00",
            "[S]": "TRUE",
            "[T]": "6175"
          }
        },
        {
          "id": "2 - Main/356-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-46-LL01",
          "quantity": 75,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 7125,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18422
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "75",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,125.00",
            "[S]": "TRUE",
            "[T]": "7125"
          }
        },
        {
          "id": "2 - Main/356-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-49-LL01",
          "quantity": 87,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 8265,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18424
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "87",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "8,265.00",
            "[S]": "TRUE",
            "[T]": "8265"
          }
        },
        {
          "id": "2 - Main/356-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-52-LL01",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 9595,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18426
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "101",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "9,595.00",
            "[S]": "TRUE",
            "[T]": "9595"
          }
        },
        {
          "id": "2 - Main/356-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From ESMDB-T4-30-LL01 to EDB-T4-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From ESMDB-T4-30-LL01 to EDB-T4-55-LL01",
          "quantity": 114,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 10830,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18428
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "114",
            "TOTAL QTY [I]": "114",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,830.00",
            "[S]": "TRUE",
            "[T]": "10830"
          }
        },
        {
          "id": "2 - Main/356-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T4-55-FAN to 32A TP fire rated isolator for T4-55-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T4-55-FAN to 32A TP fire rated isolator for T4-55-SPF-01",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 5795,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18430
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "61",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,795.00",
            "[S]": "TRUE",
            "[T]": "5795"
          }
        },
        {
          "id": "2 - Main/356-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC"
          ],
          "own_description": "From EMCC-T4-55-FAN to 32A TP fire rated isolator for T4-55-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 10mm² XLPE/SWA/FR + 1C x 10mm² ECC — From EMCC-T4-55-FAN to 32A TP fire rated isolator for T4-55-SPF-02",
          "quantity": 49,
          "unit": "m",
          "rate_aed": 95,
          "amount_aed": 4655,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18432
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "49",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,655.00",
            "[S]": "TRUE",
            "[T]": "4655"
          }
        },
        {
          "id": "2 - Main/356-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-01",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 3220,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/356-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-02",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 3335,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,335.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/356-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-03",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 4025,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,025.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/356-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T1-GF-FAN-01 to 63A TP isolator for T1-GF-CPMAF-04",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 4025,
          "amount_state": "number",
          "printed_page": "2/R/57",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,025.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/357",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 204010,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/357-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1&3-GF-LV-01 to EDB-T1&3-GF-LV 01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T1&3-GF-LV-01 to EDB-T1&3-GF-LV 01",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 2645,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18455
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,645.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-GF-LV-01 to EDB-T2-GF-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-GF-LV-01 to EDB-T2-GF-LV-01",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 1610,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18457
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-P1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T3-GF-LV01 to ESMDB-T3-P1-LL01",
          "quantity": 111,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12765,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18459
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "111",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "111",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,765.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T4-GF-LV03 to ESMDB-T4-01-LL01",
          "quantity": 111,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12765,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "111",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "111",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,765.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-01-LL01 to EDB-T4-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T4-01-LL01 to EDB-T4-02-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 2530,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,530.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-02-FAN1 to 63A TP isolator for T2-P2-CPEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-02-FAN1 to 63A TP isolator for T2-P2-CPEF-01",
          "quantity": 113,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12995,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,995.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-02-FAN1 to 63A TP isolator for T2-P2-CPEF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-02-FAN1 to 63A TP isolator for T2-P2-CPEF-03",
          "quantity": 101,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 11615,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "101",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "101",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,615.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-25-LL01",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 10580,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,580.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10580"
          }
        },
        {
          "id": "2 - Main/357-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-28-LL01",
          "quantity": 104,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 11960,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "104",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,960.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-11960"
          }
        },
        {
          "id": "2 - Main/357-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T1-P3-LL01 to EDB-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T1-P3-LL01 to EDB-T1-29-LL01",
          "quantity": 105,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12075,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "105",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "105",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,075.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12075"
          }
        },
        {
          "id": "2 - Main/357-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-25-LL01",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 10925,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "95",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,925.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-28-LL01",
          "quantity": 107,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12305,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "107",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,305.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-03-LL01 to EDB-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-03-LL01 to EDB-T2-29-LL01",
          "quantity": 110,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12650,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "110",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "110",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,650.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-25-LL01",
          "quantity": 93,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 10695,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "93",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "10,695.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-28-LL01",
          "quantity": 105,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12075,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "105",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,075.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-P3-LL01 to EDB-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T3-P3-LL01 to EDB-T3-29-LL01",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12535,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "109",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,535.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-25-LL01",
          "quantity": 94,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 10810,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "94",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,810.00",
            "[S]": "TRUE",
            "[T]": "10810"
          }
        },
        {
          "id": "2 - Main/357-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-28-LL01",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12190,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "106",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,190.00",
            "[S]": "TRUE",
            "[T]": "12190"
          }
        },
        {
          "id": "2 - Main/357-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-03-LL01 to EDB-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T4-03-LL01 to EDB-T4-29-LL01",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 12880,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "112",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,880.00",
            "[S]": "TRUE",
            "[T]": "12880"
          }
        },
        {
          "id": "2 - Main/357-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T3-B2-LL01 to EDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T3-B2-LL01 to EDB-T3-GF-LL01",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 2875,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,875.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/357-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T4-GF-LV03 to EDB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 16mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T4-GF-LV03 to EDB-T4-GF-LL01",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 115,
          "amount_aed": 2530,
          "amount_state": "number",
          "printed_page": "2/R/58",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,530.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/358",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 143840,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/358-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-B1-FAN1 to 63A TP isolator for T2-BF1-CPMAF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-B1-FAN1 to 63A TP isolator for T2-BF1-CPMAF-01",
          "quantity": 72,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 11520,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18508
          },
          "extra_columns": {
            "Basement [C]": "72",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "72",
            "BASEMENTS [M]": "11,520.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-B1-FAN1 to 63A TP isolator for T2-BF1-CPMAF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-B1-FAN1 to 63A TP isolator for T2-BF1-CPMAF-02",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18510
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "11,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-B1-FAN1 to 80A TP isolator for T2-BF1-CPMAF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-B1-FAN1 to 80A TP isolator for T2-BF1-CPMAF-03",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18512
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "11,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-B1-FAN1 to 80A TP isolator for T2-BF1-CPMAF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-B1-FAN1 to 80A TP isolator for T2-BF1-CPMAF-04",
          "quantity": 71,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 11360,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18514
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "11,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-GF-FAN-02 to 20A TP isolator for T2-GF-SPF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-GF-FAN-02 to 20A TP isolator for T2-GF-SPF",
          "quantity": 37,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 32A TP isolator for T4-GF-SPF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 32A TP isolator for T4-GF-SPF-01",
          "quantity": 82,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 13120,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 32A TP isolator for T4-GF-SPF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 32A TP isolator for T4-GF-SPF-02",
          "quantity": 97,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 15520,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "97",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "97",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-01",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5440,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-02",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-05",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 63A TP isolator for T4-GF-CPMAF-05",
          "quantity": 108,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 17280,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "108",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "108",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 80A TP isolator for T4-GF-CPMAF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 80A TP isolator for T4-GF-CPMAF-03",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18528
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-GF-FAN1 to 80A TP isolator for T4-GF-CPMAF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-GF-FAN1 to 80A TP isolator for T4-GF-CPMAF-04",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18530
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/358-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to EMCC-T3-02-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T3-GF-LV01 to EMCC-T3-02-FAN1",
          "quantity": 150,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 24000,
          "amount_state": "number",
          "printed_page": "2/R/59",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18532
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "150",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "150",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/359",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 141600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/359-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-01",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4320,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-02",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4000,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-03",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5120,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-01-FAN-01 to 63A TP  isolator for T2-P1-CPEF-04",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 5120,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18551
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-01",
          "quantity": 53,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 8480,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18553
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "53",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "53",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-02",
          "quantity": 56,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 8960,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-03",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 9760,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T3-01-FAN1 to 80A TP isolator for T3-P2-CPEF-04",
          "quantity": 61,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 9760,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "61",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-01",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4480,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-02",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 4800,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "30",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-01-LL01 to EDB-T2-01-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-01-LL01 to EDB-T2-01-LL02",
          "quantity": 14,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 2240,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-01-FAN1 to 63A TP isolator for T4-P2-CPEF-03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-01-FAN1 to 63A TP isolator for T4-P2-CPEF-03",
          "quantity": 164,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 26240,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "164",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "164",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T4-01-FAN1 to 80A TP isolator for T4-P2-CPEF-04",
          "quantity": 166,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 26560,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "166",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "166",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From ESMDB-T2-01-LL01 to EDB-T2-02-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From ESMDB-T2-01-LL01 to EDB-T2-02-LL02",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 3680,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/359-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-02-FAN1 to 80A TP isolator for T2-P2-CPEF-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-02-FAN1 to 80A TP isolator for T2-P2-CPEF-02",
          "quantity": 113,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 18080,
          "amount_state": "number",
          "printed_page": "2/R/60",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/360",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 542120,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/360-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMCC-T2-02-FAN1 to 80A TP isolator for T2-P2-CPEF-04",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMCC-T2-02-FAN1 to 80A TP isolator for T2-P2-CPEF-04",
          "quantity": 99,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 15840,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18586
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "99",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to EMCC-T2-59-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 25mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T2-GF-LV02 to EMCC-T2-59-FAN",
          "quantity": 295,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 47200,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18588
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "295",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "295",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "47,200.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T1-GF-LV01 to ESMDB-T1-B2-LL01",
          "quantity": 117,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 22464,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18592
          },
          "extra_columns": {
            "Basement [C]": "117",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "22,464.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T2-GF-LV02 to ESMDB-T2-B2-LL01",
          "quantity": 79,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 15168,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18594
          },
          "extra_columns": {
            "Basement [C]": "79",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "15,168.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T3-GF-LV01 to ESMDB-T3-B2-LL01",
          "quantity": 112,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 21504,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18596
          },
          "extra_columns": {
            "Basement [C]": "112",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "112",
            "BASEMENTS [M]": "21,504.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-GF-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T2-GF-LV02 to ESMDB-T2-GF-LV-01",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 4608,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18598
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,608.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1-P1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T1-GF-LV01 to ESMDB-T1-P1-LL01",
          "quantity": 113,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 21696,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18600
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,696.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to EMCC-T1-30-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T1-GF-LV01 to EMCC-T1-30-FAN",
          "quantity": 230,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 44160,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18602
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "230",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "230",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "44,160.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-44160"
          }
        },
        {
          "id": "2 - Main/360-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to EMCC-T1-51-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T1-GF-LV01 to EMCC-T1-51-FAN",
          "quantity": 303,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 58176,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18604
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "303",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "303",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "58,176.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-58176"
          }
        },
        {
          "id": "2 - Main/360-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to EMCC-T3-30-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T3-GF-LV01 to EMCC-T3-30-FAN",
          "quantity": 223,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 42816,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18606
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "223",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "223",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "42,816.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to EMCC-T4-30-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T4-GF-LV03 to EMCC-T4-30-FAN",
          "quantity": 224,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 43008,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18608
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "224",
            "TOTAL QTY [I]": "224",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "43,008.00",
            "[S]": "TRUE",
            "[T]": "43008"
          }
        },
        {
          "id": "2 - Main/360-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to EMCC-T4-55-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 35mm² XLPE/SWA/FR + 1C x 16mm² ECC — From EMDB-T4-GF-LV03 to EMCC-T4-55-FAN",
          "quantity": 315,
          "unit": "m",
          "rate_aed": 192,
          "amount_aed": 60480,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18610
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "315",
            "TOTAL QTY [I]": "315",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "60,480.00",
            "[S]": "TRUE",
            "[T]": "60480"
          }
        },
        {
          "id": "2 - Main/360-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 50mm² XLPE/SWA/FR + 1C x 25mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to EMCC-T2-30-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 50mm² XLPE/SWA/FR + 1C x 25mm² ECC — From EMDB-T2-GF-LV02 to EMCC-T2-30-FAN",
          "quantity": 186,
          "unit": "m",
          "rate_aed": 290,
          "amount_aed": 53940,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18614
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "186",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "186",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "53,940.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/360-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 50mm² XLPE/SWA/FR + 1C x 25mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-55-FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 50mm² XLPE/SWA/FR + 1C x 25mm² ECC — From EMDB-T3-GF-LV01 to ESMDB-T3-55-FAN",
          "quantity": 314,
          "unit": "m",
          "rate_aed": 290,
          "amount_aed": 91060,
          "amount_state": "number",
          "printed_page": "2/R/61",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18616
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "314",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "314",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "91,060.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/361",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 997950,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/361-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1&3-GF-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T1-GF-LV01 to ESMDB-T1&3-GF-LV-01",
          "quantity": 41,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 15990,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18631
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "41",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "41",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-GF-LV03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T4-GF-LV03 to ESMDB-T4-GF-LV03",
          "quantity": 24,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 9360,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18633
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T2-GF-LV02 to ESMDB-T2-01-LL01",
          "quantity": 77,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 30030,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18635
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,030.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to 100A TP isolator for lift (ISO-T1-52-FLIFT)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T1-GF-LV01 to 100A TP isolator for lift (ISO-T1-52-FLIFT)",
          "quantity": 341,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 132990,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18637
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "341",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "341",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "132,990.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-132990"
          }
        },
        {
          "id": "2 - Main/361-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to 100A TP isolator for ISO-T2-60-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T2-GF-LV02 to 100A TP isolator for ISO-T2-60-LIFT",
          "quantity": 330,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 128700,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18639
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "330",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "330",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "128,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to 100A TP isolator for lift (ISO-T1-56-LIFT)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T3-GF-LV01 to 100A TP isolator for lift (ISO-T1-56-LIFT)",
          "quantity": 347,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 135330,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "347",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "347",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "135,330.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to 100A TP isolator for ISO-T4-56-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 70mm² XLPE/SWA/FR + 1C x 35mm² ECC — From EMDB-T4-GF-LV03 to 100A TP isolator for ISO-T4-56-LIFT",
          "quantity": 351,
          "unit": "m",
          "rate_aed": 390,
          "amount_aed": 136890,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18643
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "351",
            "TOTAL QTY [I]": "351",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "136,890.00",
            "[S]": "TRUE",
            "[T]": "136890"
          }
        },
        {
          "id": "2 - Main/361-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to EMCC-T1-GF-FAN-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T1-GF-LV01 to EMCC-T1-GF-FAN-01",
          "quantity": 67,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 32830,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18647
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "67",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "67",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,830.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1-P3-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T1-GF-LV01 to ESMDB-T1-P3-LL01",
          "quantity": 133,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 65170,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18649
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "133",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "133",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,170.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T2-GF-LV02 to ESMDB-T2-03-LL01",
          "quantity": 92,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 45080,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18651
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "92",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "92",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-P3-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T3-GF-LV01 to ESMDB-T3-P3-LL01",
          "quantity": 129,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 63210,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18653
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "129",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "129",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "63,210.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/361-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1-30-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T1-GF-LV01 to ESMDB-T1-30-LL01",
          "quantity": 222,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 108780,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18655
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "222",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "222",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "108,780.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108780"
          }
        },
        {
          "id": "2 - Main/361-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-30-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T2-GF-LV02 to ESMDB-T2-30-LL01",
          "quantity": 191,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 93590,
          "amount_state": "number",
          "printed_page": "2/R/62",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18657
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "191",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "191",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "93,590.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/362",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1348525,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/362-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
            "4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-30-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Fire rated cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4C x 95mm² XLPE/SWA/FR + 1C x 50mm² ECC — From EMDB-T4-GF-LV03 to ESMDB-T4-30-LL01",
          "quantity": 227,
          "unit": "m",
          "rate_aed": 490,
          "amount_aed": 111230,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "227",
            "TOTAL QTY [I]": "227",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "111,230.00",
            "[S]": "TRUE",
            "[T]": "111230"
          }
        },
        {
          "id": "2 - Main/362-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to EMCC-T2-B1-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T2-GF-LV02 to EMCC-T2-B1-FAN1",
          "quantity": 68,
          "unit": "m",
          "rate_aed": 755,
          "amount_aed": 51340,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18674
          },
          "extra_columns": {
            "Basement [C]": "68",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "68",
            "BASEMENTS [M]": "51,340.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to EMCC-T2-02-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T2-GF-LV02 to EMCC-T2-02-FAN1",
          "quantity": 76,
          "unit": "m",
          "rate_aed": 755,
          "amount_aed": 57380,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18676
          },
          "extra_columns": {
            "Basement [C]": "20",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "15,100.00",
            "GF & PODIUM [N]": "42,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-30-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 150mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T3-GF-LV01 to ESMDB-T3-30-LL01",
          "quantity": 217,
          "unit": "m",
          "rate_aed": 755,
          "amount_aed": 163835,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18678
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "217",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "217",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "163,835.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to EMCC-T4-GF-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T4-GF-LV03 to EMCC-T4-GF-FAN1",
          "quantity": 88,
          "unit": "m",
          "rate_aed": 920,
          "amount_aed": 80960,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18682
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "88",
            "BASEMENTS [M]": "10,120.00",
            "GF & PODIUM [N]": "70,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to EMCC-T3-01-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T3-GF-LV01 to EMCC-T3-01-FAN1",
          "quantity": 162,
          "unit": "m",
          "rate_aed": 920,
          "amount_aed": 149040,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "162",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "162",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "149,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T4-GF-LV03 to ESMDB-T4-03-LL01",
          "quantity": 127,
          "unit": "m",
          "rate_aed": 920,
          "amount_aed": 116840,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "127",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "127",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "116,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to EMCC-T4-01-FAN1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4C x 185mm² XLPE/SWA/FR + 1C x 95mm² ECC — From EMDB-T4-GF-LV03 to EMCC-T4-01-FAN1",
          "quantity": 160,
          "unit": "m",
          "rate_aed": 920,
          "amount_aed": 147200,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "160",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "160",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "147,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 95mm² XLPE/SWA/FR + 2 x 1C x 50mm² ECC"
          ],
          "own_description": "From LV-T2-GF-LL04 to 350A TP isolator, fire rated for FP-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 95mm² XLPE/SWA/FR + 2 x 1C x 50mm² ECC — From LV-T2-GF-LL04 to 350A TP isolator, fire rated for FP-T2-48-LL01",
          "quantity": 280,
          "unit": "m",
          "rate_aed": 980,
          "amount_aed": 274400,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18692
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "280",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "280",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "274,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/362-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 150mm² XLPE/SWA/FR/Cu + 2 x 1C x 70mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to 400A TP isolator, fire rated for FP-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 150mm² XLPE/SWA/FR/Cu + 2 x 1C x 70mm² ECC (Fire Rated) — From LV-T1&3-GF-LL03 to 400A TP isolator, fire rated for FP-T3-B2-LL01",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 1510,
          "amount_aed": 196300,
          "amount_state": "number",
          "printed_page": "2/R/63",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18696
          },
          "extra_columns": {
            "Basement [C]": "130",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "196,300.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/363",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 6280390,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/363-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 150mm² XLPE/SWA/FR/Cu + 2 x 1C x 70mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T2-GF-LL03 to 400A TP isolator, fire rated for FP-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 150mm² XLPE/SWA/FR/Cu + 2 x 1C x 70mm² ECC (Fire Rated) — From LV-T2-GF-LL03 to 400A TP isolator, fire rated for FP-T2-29-LL01",
          "quantity": 209,
          "unit": "m",
          "rate_aed": 1510,
          "amount_aed": 315590,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18708
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "209",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "209",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "315,590.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/363-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 185mm² XLPE/SWA/FR/Cu + 2 x 1C x 95mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T4-GF-LL04 to 500A TP isolator, fire rated for FP-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 185mm² XLPE/SWA/FR/Cu + 2 x 1C x 95mm² ECC (Fire Rated) — From LV-T4-GF-LL04 to 500A TP isolator, fire rated for FP-T4-29-LL01",
          "quantity": 245,
          "unit": "m",
          "rate_aed": 1840,
          "amount_aed": 450800,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18712
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "245",
            "TOTAL QTY [I]": "245",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "450,800.00",
            "[S]": "TRUE",
            "[T]": "450800"
          }
        },
        {
          "id": "2 - Main/363-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From EMDB-T1-GF-LV01 to ESMDB-T1-51-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From EMDB-T1-GF-LV01 to ESMDB-T1-51-LIFT",
          "quantity": 307,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 736800,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18716
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "307",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "307",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "736,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-736800"
          }
        },
        {
          "id": "2 - Main/363-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T1-GF-LL06 to 630A TP isolator, fire rated for FP-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From LV-T1-GF-LL06 to 630A TP isolator, fire rated for FP-T1-29-LL01",
          "quantity": 258,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 619200,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18718
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "258",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "258",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "619,200.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-619200"
          }
        },
        {
          "id": "2 - Main/363-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From EMDB-T2-GF-LV02 to ESMDB-T2-59-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From EMDB-T2-GF-LV02 to ESMDB-T2-59-LIFT",
          "quantity": 301,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 722400,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18720
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "301",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "301",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "722,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/363-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-55-LIFT1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From EMDB-T3-GF-LV01 to ESMDB-T3-55-LIFT1",
          "quantity": 319,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 765600,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "319",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "319",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "765,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/363-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From EMDB-T3-GF-LV01 to ESMDB-T3-55-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From EMDB-T3-GF-LV01 to ESMDB-T3-55-LIFT2",
          "quantity": 316,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 758400,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "316",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "316",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "758,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/363-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T3-GF-LL07 to 630A TP isolator, fire rated for FP-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From LV-T3-GF-LL07 to 630A TP isolator, fire rated for FP-T3-29-LL01",
          "quantity": 267,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 640800,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "267",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "267",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "640,800.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/363-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated)"
          ],
          "own_description": "From EMDB-T4-GF-LV03 to ESMDB-T4-55-LIFT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 240mm² XLPE/SWA/FR/Cu + 2 x 1C x 120mm² ECC (Fire Rated) — From EMDB-T4-GF-LV03 to ESMDB-T4-55-LIFT",
          "quantity": 317,
          "unit": "m",
          "rate_aed": 2400,
          "amount_aed": 760800,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18728
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "317",
            "TOTAL QTY [I]": "317",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "760,800.00",
            "[S]": "TRUE",
            "[T]": "760800"
          }
        },
        {
          "id": "2 - Main/363-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "2 x 4C x 300mm² XLPE/SWA/FR/Cu + 2 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T1&3-GF-LL03 to 630A TP isolator, fire rated for FP-T3-P2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 2 x 4C x 300mm² XLPE/SWA/FR/Cu + 2 x 1C x 150mm² ECC (Fire Rated) — From LV-T1&3-GF-LL03 to 630A TP isolator, fire rated for FP-T3-P2-LL01",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 3000,
          "amount_aed": 510000,
          "amount_state": "number",
          "printed_page": "2/R/64",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18732
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "170",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "510,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/364",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3044000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/364-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From Generator Panel (GEN 2-GF-LV03) to EMDB-T2-GF-LV02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From Generator Panel (GEN 2-GF-LV03) to EMDB-T2-GF-LV02",
          "quantity": 269,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 1614000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "269",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "269",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,614,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From Generator Panel (GEN 2-GF-LV03) to EMDB-T4-GF-LV03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From Generator Panel (GEN 2-GF-LV03) to EMDB-T4-GF-LV03",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 120000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "120,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From Generator Panel (GEN-T1&3-GF-LV01) to EMDB-T1-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From Generator Panel (GEN-T1&3-GF-LV01) to EMDB-T1-GF-LV01",
          "quantity": 19,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 114000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18752
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "114,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From Generator Panel (GEN-T1&3-GF-LV01) to EMDB-T3-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From Generator Panel (GEN-T1&3-GF-LV01) to EMDB-T3-GF-LV01",
          "quantity": 49,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 294000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18754
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "49",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "294,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T3-GF-LL07 to EMDB-T1-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From LV-T3-GF-LL07 to EMDB-T1-GF-LV01",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 192000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18756
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "192,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T3-GF-LL07 to EMDB-T3-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From LV-T3-GF-LL07 to EMDB-T3-GF-LV01",
          "quantity": 38,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 228000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18758
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "228,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T4-GF-LL03 to EMDB-T4-GF-LV03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 4 x 4C x 300mm² XLPE/SWA/FR/Cu + 4 x 1C x 150mm² ECC (Fire Rated) — From LV-T4-GF-LL03 to EMDB-T4-GF-LV03",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 6000,
          "amount_aed": 132000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "132,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "6 x 4C x 300mm² XLPE/SWA/FR/Cu + 6 x 1C x 150mm² ECC (Fire Rated)"
          ],
          "own_description": "From LV-T3-GF-LL07 to Generator Panel (GEN-T1&3-GF-LV01)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — 6 x 4C x 300mm² XLPE/SWA/FR/Cu + 6 x 1C x 150mm² ECC (Fire Rated) — From LV-T3-GF-LL07 to Generator Panel (GEN-T1&3-GF-LV01)",
          "quantity": 35,
          "unit": "m",
          "rate_aed": 9000,
          "amount_aed": 315000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18764
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "315,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/364-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator at water feature pump room",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator at water feature pump room",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18768
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-B1-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18770
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-B1-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18772
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-B1-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18774
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-B2-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18776
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-B2-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18778
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/364-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SMDB-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SMDB-T3-B1-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/65",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18780
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/365",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 105000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/365-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SMDB-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SMDB-T3-B2-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18794
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to DB-T2-GF-SS-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to DB-T2-GF-SS-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "empty",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18796
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to DB-T3-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to DB-T3-GF-LL02",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18798
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to DB-T2-03-KDCB",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to DB-T2-03-KDCB",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18800
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to EDB-T2-GF-ETS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to EDB-T2-GF-ETS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18802
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to EDB-T2-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to EDB-T2-GF-LL02",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18804
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to EMCC-T2-GF-FAN-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to EMCC-T2-GF-FAN-02",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18806
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18808
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A TP isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18810
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SP isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18812
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to TPN isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18814
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SMDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SMDB-T3-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18816
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SMDB-T3-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SMDB-T3-GF-LL02",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18818
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to SMDB-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to SMDB-T3-01-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18820
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to UDB-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to UDB-T1-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18822
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to UDB-T2-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to UDB-T2-GF-LV01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18824
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to UDB-T4-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to UDB-T4-GF-LV01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18826
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to UDB-T4-GF-SEC-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to UDB-T4-GF-SEC-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18828
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to USMDB-T2-BR-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to USMDB-T2-BR-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18830
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to USMDB-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to USMDB-T2-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18832
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to USMDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to USMDB-T3-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18834
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/365-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to USMDB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to USMDB-T4-GF-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/66",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18836
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/366",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 85000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/366-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T1-50-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T1-50-LIFT2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18849
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T1-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T1-59-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18851
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18853
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for HEAT RECOVERY WHEEL",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for HEAT RECOVERY WHEEL",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18855
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP isolator for BOOSTER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP isolator for BOOSTER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18857
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for CBS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for CBS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18859
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for FAHU-EXTRACTION FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for FAHU-EXTRACTION FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18861
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for FAHU-SUPPLYFAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for FAHU-SUPPLYFAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18863
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for HEATER",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for HEATER",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18865
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for JOCKEY PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for JOCKEY PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18867
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18869
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP isolator for T1-51F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP isolator for T1-51F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18871
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A TP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A TP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18873
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for shaft lighting",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for shaft lighting",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18875
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-29-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18877
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-29-FP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18879
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/366-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-29-JP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/67",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18881
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/367",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 85000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/367-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-29-TP1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18900
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-29-TP2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18902
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T1-51-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T1-51-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18904
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to EMCC-48-T2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to EMCC-48-T2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18906
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T2-59-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T2-59-LIFT2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18908
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T2-59-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18910
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for HEAT RECOVERY WHEEL",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for HEAT RECOVERY WHEEL",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18912
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for T2-29F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for T2-29F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18914
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP isolator for BOOSTER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP isolator for BOOSTER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18916
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP isolator for WATER TRANSFER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP isolator for WATER TRANSFER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18918
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP fire rated isolator for JOCKEY PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP fire rated isolator for JOCKEY PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18920
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for CBS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for CBS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18922
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for FAHU-EXTRACT FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for FAHU-EXTRACT FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18924
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for FAHU-SUPPLY FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for FAHU-SUPPLY FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18926
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for HEATER",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for HEATER",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18928
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator for CHWP-1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator for CHWP-1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18930
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/367-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator for CHWP-2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator for CHWP-2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/68",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18932
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/368",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 80000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/368-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator for CHWP-3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator for CHWP-3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18947
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for T2-48F-FPEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for T2-48F-FPEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18949
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP isolator for TRANSFER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP isolator for TRANSFER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18951
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP fire rated isolator for JOCKEY PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP fire rated isolator for JOCKEY PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18953
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A TP isolator for LEVEL 55 - GSM ETISALAT",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A TP isolator for LEVEL 55 - GSM ETISALAT",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18955
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A TP isolator for LEVEL 56 - GSM DU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A TP isolator for LEVEL 56 - GSM DU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18957
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18959
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP fire rated isolator for T2-59F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP fire rated isolator for T2-59F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18961
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18963
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 80A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 80A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18965
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for shaft lighting",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for shaft lighting",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18967
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-29-FP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18969
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-29-JP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18971
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-29-TP1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18973
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-29-TP2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18975
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/368-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-59-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-59-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/69",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18977
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/369",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 80000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/369-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-RF-FAHU1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-RF-FAHU1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18991
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-48-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-48-FP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18993
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-48-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-48-JP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18995
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-48-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-48-TP1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18997
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T2-48-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T2-48-TP2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 18999
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T3-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T3-55-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19001
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SPN isolator for GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SPN isolator for GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19003
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SPN isolator for heat recovery wheel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SPN isolator for heat recovery wheel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19005
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TPN isolator for BOOSTER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TPN isolator for BOOSTER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19007
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN fire rated isolator for jockey pump",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN fire rated isolator for jockey pump",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19009
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for CBS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for CBS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19011
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for FAHU-EXTRACTION FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for FAHU-EXTRACTION FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19013
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for FAHU-SUPPLY FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for FAHU-SUPPLY FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19015
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for HEATER",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for HEATER",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19017
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19019
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/369-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP fire rated isolator for T3-55F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP fire rated isolator for T3-55F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/70",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19021
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/370",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 90000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/370-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A TP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A TP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19034
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for shaft lighting",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for shaft lighting",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19036
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-29-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19038
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-29-FP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19040
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-29-JP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19042
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-29-TP1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19044
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-29-TP2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19046
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T3-55-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T3-55-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19048
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to EMCC-T3-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to EMCC-T3-55-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19050
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T4-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T4-53-LL01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19052
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to ESMDB-T4-59-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to ESMDB-T4-59-LIFT2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19054
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for HEAT WHEEL",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for HEAT WHEEL",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19056
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for T4-29F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for T4-29F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19058
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TPN isolator for BOOSTER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TPN isolator for BOOSTER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19060
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TPN isolator for WATER TRANSFER PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TPN isolator for WATER TRANSFER PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19062
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for CBS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for CBS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19064
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TP isolator for HEAT WHEEL",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TP isolator for HEAT WHEEL",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19066
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/370-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for FAHU-EXTRACT FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for FAHU-EXTRACT FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/71",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19068
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/371",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 510300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/371-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for FAHU-SUPPLY FAN",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for FAHU-SUPPLY FAN",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19083
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 32A TPN isolator for JOCKEY PUMP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 32A TPN isolator for JOCKEY PUMP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19085
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 40A TP isolator for CHWP-3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 40A TP isolator for CHWP-3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19087
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19089
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A TP fire rated isolator for T4-59F-GEF",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A TP fire rated isolator for T4-59F-GEF",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19091
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 63A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 63A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19093
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 80A SP isolator for FAHU-RF-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 80A SP isolator for FAHU-RF-01",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19095
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to 20A SP isolator for shaft lighting",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to 20A SP isolator for shaft lighting",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19097
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-29-TP2",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19099
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-L29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-L29-FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19101
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-L29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-L29-FP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19103
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-L29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-L29-JP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19105
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-L29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-L29-TP1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19107
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "From power supply to MCC-T4-RF-FAHU1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — From power supply to MCC-T4-RF-FAHU1",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19109
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/371-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T1-001, 1600A TPN+E Cu busbar, TCL = 993.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T1-001, 1600A TPN+E Cu busbar, TCL = 993.12kW",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 2590,
          "amount_aed": 440300,
          "amount_state": "number",
          "printed_page": "2/R/72",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19113
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "42",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "238,280.00",
            "GF & PODIUM [N]": "93,240.00",
            "TOWER 1 [O]": "108,780.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-108780"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/372",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 13253400,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/372-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T1-002, 1600A TPN+E Cu busbar, TCL = 910.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T1-002, 1600A TPN+E Cu busbar, TCL = 910.36kW",
          "quantity": 207,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 828000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19126
          },
          "extra_columns": {
            "Basement [C]": "90",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "81",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "207",
            "BASEMENTS [M]": "360,000.00",
            "GF & PODIUM [N]": "144,000.00",
            "TOWER 1 [O]": "324,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-324000"
          }
        },
        {
          "id": "2 - Main/372-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T1-003, 1600A TPN+E Cu busbar, TCL = 899.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T1-003, 1600A TPN+E Cu busbar, TCL = 899.12kW",
          "quantity": 252,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 1008000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19128
          },
          "extra_columns": {
            "Basement [C]": "89",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "123",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "252",
            "BASEMENTS [M]": "356,000.00",
            "GF & PODIUM [N]": "160,000.00",
            "TOWER 1 [O]": "492,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-492000"
          }
        },
        {
          "id": "2 - Main/372-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T1-004, 2000A TPN+E Cu busbar, TCL = 993.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T1-004, 2000A TPN+E Cu busbar, TCL = 993.46kW",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 5050,
          "amount_aed": 1515000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19130
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "39",
            "Tower 1 [E]": "169",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "464,600.00",
            "GF & PODIUM [N]": "196,950.00",
            "TOWER 1 [O]": "853,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-853450"
          }
        },
        {
          "id": "2 - Main/372-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T1-CA-005, 2500A TPN+E Cu busbar, TCL = 987.91kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T1-CA-005, 2500A TPN+E Cu busbar, TCL = 987.91kW",
          "quantity": 303,
          "unit": "m",
          "rate_aed": 4400,
          "amount_aed": 1333200,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19132
          },
          "extra_columns": {
            "Basement [C]": "89",
            "GF & Podium [D]": "42",
            "Tower 1 [E]": "172",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "303",
            "BASEMENTS [M]": "391,600.00",
            "GF & PODIUM [N]": "184,800.00",
            "TOWER 1 [O]": "756,800.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-756800"
          }
        },
        {
          "id": "2 - Main/372-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-001, 1250A TPN+E Cu busbar, TCL = 870.75kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-001, 1250A TPN+E Cu busbar, TCL = 870.75kW",
          "quantity": 117,
          "unit": "m",
          "rate_aed": 3150,
          "amount_aed": 368550,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19134
          },
          "extra_columns": {
            "Basement [C]": "50",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "157,500.00",
            "GF & PODIUM [N]": "110,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "100,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-002, 1250A TPN+E Cu busbar, TCL = 991.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-002, 1250A TPN+E Cu busbar, TCL = 991.08kW",
          "quantity": 161,
          "unit": "m",
          "rate_aed": 3150,
          "amount_aed": 507150,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19136
          },
          "extra_columns": {
            "Basement [C]": "51",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "74",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "161",
            "BASEMENTS [M]": "160,650.00",
            "GF & PODIUM [N]": "113,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "233,100.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-003, 1250A TPN+E Cu busbar, TCL = 888.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-003, 1250A TPN+E Cu busbar, TCL = 888.92kW",
          "quantity": 201,
          "unit": "m",
          "rate_aed": 3150,
          "amount_aed": 633150,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19138
          },
          "extra_columns": {
            "Basement [C]": "51",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "116",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "201",
            "BASEMENTS [M]": "160,650.00",
            "GF & PODIUM [N]": "107,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "365,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-004, 1600A TPN+E Cu busbar, TCL = 965.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-004, 1600A TPN+E Cu busbar, TCL = 965.59kW",
          "quantity": 242,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 968000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19140
          },
          "extra_columns": {
            "Basement [C]": "48",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "159",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "242",
            "BASEMENTS [M]": "192,000.00",
            "GF & PODIUM [N]": "140,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "636,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-005, 1250A TPN+E Cu busbar, TCL = 627.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-005, 1250A TPN+E Cu busbar, TCL = 627.52kW",
          "quantity": 285,
          "unit": "m",
          "rate_aed": 3150,
          "amount_aed": 897750,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19142
          },
          "extra_columns": {
            "Basement [C]": "49",
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "202",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "285",
            "BASEMENTS [M]": "154,350.00",
            "GF & PODIUM [N]": "107,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "636,300.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T2-CA-006, 2000A TPN+E Cu busbar, TCL = 655.38kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T2-CA-006, 2000A TPN+E Cu busbar, TCL = 655.38kW",
          "quantity": 292,
          "unit": "m",
          "rate_aed": 5050,
          "amount_aed": 1474600,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19144
          },
          "extra_columns": {
            "Basement [C]": "49",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "210",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "292",
            "BASEMENTS [M]": "247,450.00",
            "GF & PODIUM [N]": "166,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,060,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T3-001-R, 1600A TPN+E Cu busbar, TCL = 991.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T3-001-R, 1600A TPN+E Cu busbar, TCL = 991.08kW",
          "quantity": 163,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 652000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19146
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "49",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "163",
            "BASEMENTS [M]": "308,000.00",
            "GF & PODIUM [N]": "148,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "196,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T3-002-R, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T3-002-R, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "quantity": 214,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 856000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19148
          },
          "extra_columns": {
            "Basement [C]": "78",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "99",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "214",
            "BASEMENTS [M]": "312,000.00",
            "GF & PODIUM [N]": "148,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "396,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T3-003-R, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T3-003-R, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "quantity": 253,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 1012000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19150
          },
          "extra_columns": {
            "Basement [C]": "79",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "134",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "253",
            "BASEMENTS [M]": "316,000.00",
            "GF & PODIUM [N]": "160,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "536,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/372-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T3-004-R, 1600A TPN+E Cu busbar, TCL = 1074.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T3-004-R, 1600A TPN+E Cu busbar, TCL = 1074.18kW",
          "quantity": 300,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 1200000,
          "amount_state": "number",
          "printed_page": "2/R/73",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19152
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "183",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "300",
            "BASEMENTS [M]": "308,000.00",
            "GF & PODIUM [N]": "160,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "732,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/373",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 10414127,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/373-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T3-CA-006, 2000A TPN+E Cu busbar, TCL = 893.10kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T3-CA-006, 2000A TPN+E Cu busbar, TCL = 893.10kW",
          "quantity": 316,
          "unit": "m",
          "rate_aed": 5050,
          "amount_aed": 1595800,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19165
          },
          "extra_columns": {
            "Basement [C]": "78",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "194",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "316",
            "BASEMENTS [M]": "393,900.00",
            "GF & PODIUM [N]": "222,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "979,700.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T4-001, 1600A TPN+E Cu busbar, TCL = 991.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T4-001, 1600A TPN+E Cu busbar, TCL = 991.08kW",
          "quantity": 146,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 584000,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19167
          },
          "extra_columns": {
            "Basement [C]": "65",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "49",
            "TOTAL QTY [I]": "146",
            "BASEMENTS [M]": "260,000.00",
            "GF & PODIUM [N]": "128,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "196,000.00",
            "[S]": "TRUE",
            "[T]": "196000"
          }
        },
        {
          "id": "2 - Main/373-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T4-002, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T4-002, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "quantity": 189,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 756000,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19169
          },
          "extra_columns": {
            "Basement [C]": "67",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "91",
            "TOTAL QTY [I]": "189",
            "BASEMENTS [M]": "268,000.00",
            "GF & PODIUM [N]": "124,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "364,000.00",
            "[S]": "TRUE",
            "[T]": "364000"
          }
        },
        {
          "id": "2 - Main/373-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T4-003, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T4-003, 1600A TPN+E Cu busbar, TCL = 940.00kW",
          "quantity": 239,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 956000,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19171
          },
          "extra_columns": {
            "Basement [C]": "69",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "134",
            "TOTAL QTY [I]": "239",
            "BASEMENTS [M]": "276,000.00",
            "GF & PODIUM [N]": "144,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "536,000.00",
            "[S]": "TRUE",
            "[T]": "536000"
          }
        },
        {
          "id": "2 - Main/373-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T4-004, 1600A TPN+E Cu busbar, TCL = 883.44kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T4-004, 1600A TPN+E Cu busbar, TCL = 883.44kW",
          "quantity": 285,
          "unit": "m",
          "rate_aed": 4000,
          "amount_aed": 1140000,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19173
          },
          "extra_columns": {
            "Basement [C]": "69",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "180",
            "TOTAL QTY [I]": "285",
            "BASEMENTS [M]": "276,000.00",
            "GF & PODIUM [N]": "144,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "720,000.00",
            "[S]": "TRUE",
            "[T]": "720000"
          }
        },
        {
          "id": "2 - Main/373-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work"
          ],
          "own_description": "BB-T4-CA-005, 3200A TPN+E Cu busbar, TCL = 875.66kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Busbar including earth connectivity conductor cables, terminations, lugs, supports, accessories and all ancillary work — BB-T4-CA-005, 3200A TPN+E Cu busbar, TCL = 875.66kW",
          "quantity": 305,
          "unit": "m",
          "rate_aed": 7900,
          "amount_aed": 2409500,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19175
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "41",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "193",
            "TOTAL QTY [I]": "305",
            "BASEMENTS [M]": "560,900.00",
            "GF & PODIUM [N]": "323,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,524,700.00",
            "[S]": "TRUE",
            "[T]": "1524700"
          }
        },
        {
          "id": "2 - Main/373-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T1&3-GF-LL03, TCL = 1782.38kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T1&3-GF-LL03, TCL = 1782.38kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 267350,
          "amount_aed": 267350,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "267,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T1-GF-LL01, TCL = 1903.48kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T1-GF-LL01, TCL = 1903.48kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 285523,
          "amount_aed": 285523,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "285,523.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T1-GF-LL02, TCL = 1892.58kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T1-GF-LL02, TCL = 1892.58kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 283883,
          "amount_aed": 283883,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "283,883.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T1-GF-LL06, TCL = 1986.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T1-GF-LL06, TCL = 1986.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 318583,
          "amount_aed": 318583,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "318,583.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T2-GF-LL01, TCL = 1961.83kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T2-GF-LL01, TCL = 1961.83kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 313890,
          "amount_aed": 313890,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "313,890.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T2-GF-LL02, TCL = 1942.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T2-GF-LL02, TCL = 1942.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 310800,
          "amount_aed": 310800,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "310,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T2-GF-LL03, TCL = 2097.41kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T2-GF-LL03, TCL = 2097.41kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 335585,
          "amount_aed": 335585,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "335,585.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T2-GF-LL04, TCL = 1658.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T2-GF-LL04, TCL = 1658.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 265420,
          "amount_aed": 265420,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "265,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T3-GF-LL04, TCL = 1931.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T3-GF-LL04, TCL = 1931.08kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 289665,
          "amount_aed": 289665,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "289,665.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/373-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T3-GF-LL05, TCL = 2014.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T3-GF-LL05, TCL = 2014.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 302128,
          "amount_aed": 302128,
          "amount_state": "number",
          "printed_page": "2/R/74",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "302,128.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/374",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1945653,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/374-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T3-GF-LL07, TCL = 1867.37kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T3-GF-LL07, TCL = 1867.37kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 280106,
          "amount_aed": 280106,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19214
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280,106.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T4-GF-LL01, TCL = 1931.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T4-GF-LL01, TCL = 1931.08kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 289666,
          "amount_aed": 289666,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19216
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "289,666.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T4-GF-LL02, TCL = 1823.44kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T4-GF-LL02, TCL = 1823.44kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 273521,
          "amount_aed": 273521,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19218
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "273,521.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T4-GF-LL03, TCL = 1576.17kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T4-GF-LL03, TCL = 1576.17kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 252190,
          "amount_aed": 252190,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19220
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "252,190.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "LV panel"
          ],
          "own_description": "LV-T4-GF-LL04, TCL = 1614.27kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — LV panel — LV-T4-GF-LL04, TCL = 1614.27kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 258280,
          "amount_aed": 258280,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19222
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "258,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Emergency main distribution board"
          ],
          "own_description": "EMDB-T1-GF-LV01 (with integrated ATS), TCL = 817.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Emergency main distribution board — EMDB-T1-GF-LV01 (with integrated ATS), TCL = 817.36kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 177000,
          "amount_aed": 177000,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19226
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "177,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Emergency main distribution board"
          ],
          "own_description": "EMDB-T2-GF-LV01 (with integrated ATS), TCL = 1042.87kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Emergency main distribution board — EMDB-T2-GF-LV01 (with integrated ATS), TCL = 1042.87kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 81000,
          "amount_aed": 81000,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "81,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Emergency main distribution board"
          ],
          "own_description": "EMDB-T3-GF-LV01 (with integrated ATS), TCL = 893.62kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Emergency main distribution board — EMDB-T3-GF-LV01 (with integrated ATS), TCL = 893.62kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 150000,
          "amount_aed": 150000,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19230
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "150,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Emergency main distribution board"
          ],
          "own_description": "EMDB-T4-GF-LV03 (with integrated ATS), TCL = 1070.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Emergency main distribution board — EMDB-T4-GF-LV03 (with integrated ATS), TCL = 1070.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 81000,
          "amount_aed": 81000,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "81,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-01-BR01, TCL = 35.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-01-BR01, TCL = 35.73kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5360,
          "amount_aed": 5360,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-01-LL01, TCL = 111.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-01-LL01, TCL = 111.99kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16800,
          "amount_aed": 16800,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-02-BR01, TCL = 47.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-02-BR01, TCL = 47.15kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7080,
          "amount_aed": 7080,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-02-LL01, TCL = 16.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-02-LL01, TCL = 16.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2400,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-02-SWP, TCL = 115kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-02-SWP, TCL = 115kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 17250,
          "amount_aed": 17250,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19244
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-03-BR01, TCL = 57.98kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-03-BR01, TCL = 57.98kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8700,
          "amount_aed": 8700,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-03-LL01, TCL = 135.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-03-LL01, TCL = 135.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20400,
          "amount_aed": 20400,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/374-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-04-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-04-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/374-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-05-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-05-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/75",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19252
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/375",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 273900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/375-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-06-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-06-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-07-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-07-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-08-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-08-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-09-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-09-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-10-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-10-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-11-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-11-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-12-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-12-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-13-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-13-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-14-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-14-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-15-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-15-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-16-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-16-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-17-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-17-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-18-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-18-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-19-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-19-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-20-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-20-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-21-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-21-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-22-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-22-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-23-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-23-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-24-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-24-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19301
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-25-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-25-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19303
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-26-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-26-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/375-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-27-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-27-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/76",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/376",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 272150,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/376-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-28-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-28-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19320
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-29-BR01, TCL = 35.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-29-BR01, TCL = 35.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19322
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8500"
          }
        },
        {
          "id": "2 - Main/376-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-29-LL01, TCL = 124.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-29-LL01, TCL = 124.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18600,
          "amount_aed": 18600,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19324
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-18600"
          }
        },
        {
          "id": "2 - Main/376-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-30-BR01, TCL = 35.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-30-BR01, TCL = 35.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "8,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-8500"
          }
        },
        {
          "id": "2 - Main/376-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-31-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-31-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-32-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-32-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-33-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-33-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19332
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-34-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-34-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19334
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-35-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-35-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-36-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-36-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19338
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-37-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-37-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19340
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-38-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-38-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19342
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-39-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-39-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-40-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-40-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-41-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-41-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19348
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-42-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-42-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-43-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-43-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19352
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-44-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-44-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19354
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-45-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-45-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19356
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-46-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-46-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-47-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-47-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/376-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-48-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-48-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/77",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/377",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 312350,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/377-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-49-BR01, TCL = 82.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-49-BR01, TCL = 82.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19375
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/377-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-50-BR01, TCL = 83.1kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-50-BR01, TCL = 83.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/377-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-51-LL01, TCL = 70.4kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-51-LL01, TCL = 70.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,450.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-12450"
          }
        },
        {
          "id": "2 - Main/377-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-B1-LL01, TCL = 24.02kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-B1-LL01, TCL = 24.02kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19381
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-B2-LL01, TCL = 61.71kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-B2-LL01, TCL = 61.71kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19383
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "12,450.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-GF-EV1, TCL = 176kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-GF-EV1, TCL = 176kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26400,
          "amount_aed": 26400,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-GF-EV2, TCL = 264kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-GF-EV2, TCL = 264kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 39600,
          "amount_aed": 39600,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T1-GF-LV01, TCL = 66.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T1-GF-LV01, TCL = 66.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9750,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-01-BR01, TCL = 25.44kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-01-BR01, TCL = 25.44kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-01-LL01, TCL = 79.83kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-01-LL01, TCL = 79.83kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-02-BR01, TCL = 40.8kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-02-BR01, TCL = 40.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-02-LL01, TCL = 143.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-02-LL01, TCL = 143.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21000,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-03-BR01, TCL = 61.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-03-BR01, TCL = 61.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9750,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-03-LL01, TCL = 140.02kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-03-LL01, TCL = 140.02kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21000,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-04-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-04-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-05-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-05-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-06-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-06-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-07-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-07-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-08-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-08-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-09-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-09-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-10-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-10-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/377-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-11-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-11-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/78",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/378",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 274550,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/378-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-12-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-12-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19430
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-13-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-13-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19432
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-14-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-14-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19434
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-15-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-15-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19436
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-16-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-16-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-17-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-17-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-18-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-18-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-19-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-19-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-20-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-20-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-21-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-21-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-22-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-22-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19450
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-23-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-23-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19452
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-24-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-24-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19454
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-25-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-25-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19456
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-26-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-26-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19458
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-27-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-27-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19460
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-28-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-28-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19462
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-29-BR01, TCL = 31.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-29-BR01, TCL = 31.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19464
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-29-LL01, TCL = 144.23kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-29-LL01, TCL = 144.23kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21000,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19466
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "21,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-30-BR01, TCL = 31.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-30-BR01, TCL = 31.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "8,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-31-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-31-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19470
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/378-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-32-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-32-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/79",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19472
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/379",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 249750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/379-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-33-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-33-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19484
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-34-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-34-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19486
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-35-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-35-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19488
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-36-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-36-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19490
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-37-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-37-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19492
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-38-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-38-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19494
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-39-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-39-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19496
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-40-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-40-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19498
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-41-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-41-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19500
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-42-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-42-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19502
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-43-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-43-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19504
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-44-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-44-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19506
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-45-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-45-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19508
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-46-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-46-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19510
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-47-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-47-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19512
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "12,450.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-48-BR01, TCL = 57.1kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-48-BR01, TCL = 57.1kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19514
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-48-LL01, TCL = 58.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-48-LL01, TCL = 58.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19516
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-49-BR01, TCL = 64.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-49-BR01, TCL = 64.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-50-BR01, TCL = 64.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-50-BR01, TCL = 64.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-51-BR01, TCL = 64.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-51-BR01, TCL = 64.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-52-BR01, TCL = 64.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-52-BR01, TCL = 64.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19524
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/379-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-53-BR01, TCL = 64.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-53-BR01, TCL = 64.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/80",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19526
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/380",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 246300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/380-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-54-BR01, TCL = 55.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-54-BR01, TCL = 55.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19539
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-55-BR01, TCL = 55.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-55-BR01, TCL = 55.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19541
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-56-BR01, TCL = 55.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-56-BR01, TCL = 55.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19543
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-57-BR01, TCL = 55.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-57-BR01, TCL = 55.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-58-BR01, TCL = 84.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-58-BR01, TCL = 84.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-59-LL01, TCL = 78.32kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-59-LL01, TCL = 78.32kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19549
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "9,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-B1-LL01, TCL = 29.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-B1-LL01, TCL = 29.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19551
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "9,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-B2-LL01, TCL = 17.93kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-B2-LL01, TCL = 17.93kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19553
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-CAFE1, TCL = 65kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-CAFE1, TCL = 65kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9750,
          "amount_aed": 9750,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-CAFE2, TCL = 90kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-CAFE2, TCL = 90kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13500,
          "amount_aed": 13500,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-CAFE3, TCL = 95kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-CAFE3, TCL = 95kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 14250,
          "amount_aed": 14250,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-C-STORE(SM), TCL = 125kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-C-STORE(SM), TCL = 125kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18750,
          "amount_aed": 18750,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-EV1, TCL = 88kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-EV1, TCL = 88kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13200,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-EV2, TCL = 132kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-EV2, TCL = 132kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 19800,
          "amount_aed": 19800,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-LV, TCL = 60.9kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-LV, TCL = 60.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 9000,
          "amount_aed": 9000,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T2-GF-RET, TCL = 56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T2-GF-RET, TCL = 56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-01-BR01, TCL = 27.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-01-BR01, TCL = 27.99kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-02-BR01, TCL = 43.3kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-02-BR01, TCL = 43.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-03-BR01, TCL = 57.81kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-03-BR01, TCL = 57.81kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-03-LL01, TCL = 135.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-03-LL01, TCL = 135.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 20250,
          "amount_aed": 20250,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/380-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-04-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-04-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/81",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/381",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 248000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/381-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-05-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-05-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19594
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-06-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-06-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19596
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-07-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-07-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19598
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-08-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-08-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19600
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-09-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-09-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19602
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-10-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-10-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19604
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-11-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-11-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19606
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-12-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-12-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19608
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-13-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-13-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19610
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-14-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-14-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19612
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-15-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-15-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19614
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-16-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-16-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19616
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-17-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-17-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19618
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-18-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-18-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19620
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-19-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-19-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19622
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-20-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-20-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19624
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-21-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-21-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19626
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-22-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-22-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19628
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-23-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-23-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19630
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/381-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-24-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-24-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/82",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19632
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/382",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 268900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/382-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-25-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-25-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19650
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-26-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-26-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19652
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-27-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-27-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19654
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-28-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-28-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-29-BR01, TCL = 32.71kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-29-BR01, TCL = 32.71kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19658
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "8,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-29-LL01, TCL = 165.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-29-LL01, TCL = 165.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19660
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-31-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-31-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19662
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-32-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-32-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19664
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-33-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-33-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-34-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-34-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19668
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-35-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-35-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19670
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-36-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-36-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19672
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-37-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-37-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19674
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-38-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-38-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19676
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-39-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-39-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19678
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-40-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-40-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19680
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-41-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-41-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19682
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-42-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-42-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-43-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-43-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-44-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-44-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-45-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-45-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19690
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/382-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-46-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-46-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/83",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19692
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/383",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 367200,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/383-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-47-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-47-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-48-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-48-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19707
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-49-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-49-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19709
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-50-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-50-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19711
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-51-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-51-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19713
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-52-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-52-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19715
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-53-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-53-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-54-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-54-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-55-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-55-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-56-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-56-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19723
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-57-LL01, TCL = 165.69kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-57-LL01, TCL = 165.69kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 24750,
          "amount_aed": 24750,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "24,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-58-BR01, TCL = 83.10kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-58-BR01, TCL = 83.10kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-59-LL01, TCL = 82.40kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-59-LL01, TCL = 82.40kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19731
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "10,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19733
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "10,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T3-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T3-GF-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-01-BR01, TCL = 35.57kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-01-BR01, TCL = 35.57kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19739
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-01-LL01, TCL = 55.43kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-01-LL01, TCL = 55.43kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19741
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-02-BR01, TCL = 50.93kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-02-BR01, TCL = 50.93kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19743
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-02-LL01, TCL = 155.22kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-02-LL01, TCL = 155.22kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 23250,
          "amount_aed": 23250,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19745
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-02-SWP, TCL = 230kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-02-SWP, TCL = 230kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 34500,
          "amount_aed": 34500,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19747
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-03-BR01, TCL = 61.23kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-03-BR01, TCL = 61.23kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12450,
          "amount_aed": 12450,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19749
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-Z",
          "item_code": "Z",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-03-LL01, TCL = 155.22kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-03-LL01, TCL = 155.22kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 23250,
          "amount_aed": 23250,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/383-AA",
          "item_code": "AA",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-04-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-04-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19753
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/383-AB",
          "item_code": "AB",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-05-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-05-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/84",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19755
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/384",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 272800,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/384-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-06-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-06-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19765
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-07-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-07-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19767
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-08-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-08-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19769
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-09-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-09-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19771
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-10-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-10-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19773
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-11-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-11-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-12-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-12-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-13-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-13-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-14-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-14-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-15-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-15-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-16-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-16-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-17-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-17-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-18-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-18-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-19-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-19-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-20-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-20-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-21-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-21-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-22-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-22-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-23-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-23-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-24-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-24-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-25-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-25-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-26-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-26-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/384-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-27-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-27-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/85",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/385",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 272800,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/385-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-28-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-28-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19820
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-29-BR01, TCL = 31.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-29-BR01, TCL = 31.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19822
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-29-LL01, TCL = 211.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-29-LL01, TCL = 211.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19824
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-30-BR01, TCL = 31.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-30-BR01, TCL = 31.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19826
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-31-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-31-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19828
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-32-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-32-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19830
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-33-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-33-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19832
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-34-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-34-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19834
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-35-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-35-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19836
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-36-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-36-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19838
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-37-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-37-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19840
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-38-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-38-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19842
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-39-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-39-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19844
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-40-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-40-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19846
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-41-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-41-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19848
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-42-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-42-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19850
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-43-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-43-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19852
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-44-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-44-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19854
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-45-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-45-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19856
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-46-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-46-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19858
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-47-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-47-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19860
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/385-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-48-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-48-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/86",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19862
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/386",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 316220,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/386-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-49-BR01, TCL = 82.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-49-BR01, TCL = 82.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19875
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/386-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-50-BR01, TCL = 57.98kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-50-BR01, TCL = 57.98kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19877
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/386-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-51-BR01, TCL = 57.98kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-51-BR01, TCL = 57.98kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/386-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-52-BR01, TCL = 57.98kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-52-BR01, TCL = 57.98kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19881
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/386-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-53-BR01, TCL = 142.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-53-BR01, TCL = 142.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21300,
          "amount_aed": 21300,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,300.00",
            "[S]": "TRUE",
            "[T]": "21300"
          }
        },
        {
          "id": "2 - Main/386-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-54-BR01, TCL = 84.20kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-54-BR01, TCL = 84.20kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12400,
          "amount_aed": 12400,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19885
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "12,400.00",
            "[S]": "TRUE",
            "[T]": "12400"
          }
        },
        {
          "id": "2 - Main/386-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-55-LL01, TCL = 74.82kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-55-LL01, TCL = 74.82kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 11220,
          "amount_aed": 11220,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "11,220.00",
            "[S]": "TRUE",
            "[T]": "11220"
          }
        },
        {
          "id": "2 - Main/386-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-B1-LL01, TCL = 14.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-B1-LL01, TCL = 14.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19889
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-B2-LL01, TCL = 14.81kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-B2-LL01, TCL = 14.81kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19891
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "8,500.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-GF-EV1, TCL = 132kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-GF-EV1, TCL = 132kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 19800,
          "amount_aed": 19800,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-GF-EV2, TCL = 88kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-GF-EV2, TCL = 88kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 13200,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19895
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "Sub-main distribution board"
          ],
          "own_description": "SMDB-T4-GF-LL01, TCL = 46.17kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — Sub-main distribution board — SMDB-T4-GF-LL01, TCL = 46.17kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 8500,
          "amount_aed": 8500,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1&3-GF-LV-01, TCL = 68.55kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1&3-GF-LV-01, TCL = 68.55kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19903
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-30-LL01, TCL = 93.75kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-30-LL01, TCL = 93.75kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-18900"
          }
        },
        {
          "id": "2 - Main/386-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-50-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-50-LIFT2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,900.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-18900"
          }
        },
        {
          "id": "2 - Main/386-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-51-LIFT, TCL = 306kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-51-LIFT, TCL = 306kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 46500,
          "amount_aed": 46500,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "46,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-46500"
          }
        },
        {
          "id": "2 - Main/386-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-59-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-15000"
          }
        },
        {
          "id": "2 - Main/386-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-B2-LL01, TCL = 20.91kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-B2-LL01, TCL = 20.91kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19913
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "15,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-P1-LL01, TCL = 35.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-P1-LL01, TCL = 35.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T1-P3-LL01, TCL = 85.33kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T1-P3-LL01, TCL = 85.33kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/386-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-01-LL01, TCL = 52.19kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-01-LL01, TCL = 52.19kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/87",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/387",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 471600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/387-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-03-LL01, TCL = 82.98kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-03-LL01, TCL = 82.98kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19932
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-30-LL01, TCL = 86.26kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-30-LL01, TCL = 86.26kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19934
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-60-LIFT, TCL = 366kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-60-LIFT, TCL = 366kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 54900,
          "amount_aed": 54900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19936
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "54,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-59-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-59-LIFT2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19938
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-59-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19940
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "18,900.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-B2-LL01, TCL = 32.64kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-B2-LL01, TCL = 32.64kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19942
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "15,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T2-GF-LV-01, TCL = 60.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T2-GF-LV-01, TCL = 60.08kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19944
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-30-LL01, TCL = 99.26kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-30-LL01, TCL = 99.26kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19946
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "18,900.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-57-LIFT1, TCL = 213kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-57-LIFT1, TCL = 213kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 31950,
          "amount_aed": 31950,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19948
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-57-LIFT2, TCL = 213kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-57-LIFT2, TCL = 213kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 31950,
          "amount_aed": 31950,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19950
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,950.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-57-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-57-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19952
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "15,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-B2-LL01, TCL = 29.30kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-B2-LL01, TCL = 29.30kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19954
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "15,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-P1-LL01, TCL = 12.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-P1-LL01, TCL = 12.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19956
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T3-P3-LL01, TCL = 84.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T3-P3-LL01, TCL = 84.92kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19958
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-01-LL01, TCL = 12.03kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-01-LL01, TCL = 12.03kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19960
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-03-LL01, TCL = 81.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-03-LL01, TCL = 81.42kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19962
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-30-LL01, TCL = 102.74kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-30-LL01, TCL = 102.74kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19964
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "18,900.00",
            "[S]": "TRUE",
            "[T]": "18900"
          }
        },
        {
          "id": "2 - Main/387-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-53-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19966
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "18,900.00",
            "[S]": "TRUE",
            "[T]": "18900"
          }
        },
        {
          "id": "2 - Main/387-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-55-LIFT, TCL = 366kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-55-LIFT, TCL = 366kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 54900,
          "amount_aed": 54900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19968
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "54,900.00",
            "[S]": "TRUE",
            "[T]": "54900"
          }
        },
        {
          "id": "2 - Main/387-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-59-LIFT2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-59-LIFT2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19970
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "18,900.00",
            "[S]": "TRUE",
            "[T]": "18900"
          }
        },
        {
          "id": "2 - Main/387-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-B2-LL01, TCL = 15.05kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-B2-LL01, TCL = 15.05kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19972
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "15,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/387-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, accessories and all ancillary works as necessary",
            "SMDB-T4-48-LL01, TCL = 187.1kW",
            "Emergency sub-main distribution board"
          ],
          "own_description": "ESMDB-T4-GF-LV03, TCL = 105.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Equipment; including fixings, supports, accessories and all ancillary works as necessary — SMDB-T4-48-LL01, TCL = 187.1kW — Emergency sub-main distribution board — ESMDB-T4-GF-LV03, TCL = 105.42kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/88",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/388",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 485100,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/388-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible sub-main distribution board"
          ],
          "own_description": "USMDB-T2-BR-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible sub-main distribution board — USMDB-T2-BR-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19993
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible sub-main distribution board"
          ],
          "own_description": "USMDB-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible sub-main distribution board — USMDB-T2-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19995
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible sub-main distribution board"
          ],
          "own_description": "USMDB-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible sub-main distribution board — USMDB-T3-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19997
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible sub-main distribution board"
          ],
          "own_description": "USMDB-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible sub-main distribution board — USMDB-T4-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18900,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 19999
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-PHARMACY, TCL = 20kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-PHARMACY, TCL = 20kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20003
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-SALOON, TCL = 20kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-SALOON, TCL = 20kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20005
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1&3-GF-LL01, TCL = 21.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1&3-GF-LL01, TCL = 21.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1&3-GF-SS01, TCL=1.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1&3-GF-SS01, TCL=1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/388-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-1BA1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-1BC1, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20013
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-1BC2, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20015
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-1BD1, TCL = 7.72kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-1BD1, TCL = 7.72kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-2BA1, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-2BA2, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-2BB1, TCL = 10.12kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-2BC1, TCL = 10.15kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(04-15)-3BB1, TCL = 11.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(04-15)-3BB1, TCL = 11.42kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-31500"
          }
        },
        {
          "id": "2 - Main/388-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-1BA1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/388-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-1BC1, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/388-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-1BC2, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/388-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-1BD1, TCL = 7.72kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-1BD1, TCL = 7.72kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/89",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20035
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/389",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 517125,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/389-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-2BA1, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20048
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-2BA2, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20050
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-2BB1, TCL = 10.12kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20052
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-2BC1, TCL = 10.15kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20054
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(16-26)-3BB1, TCL = 11.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(16-26)-3BB1, TCL = 11.42kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-1BA1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20058
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-1BC1, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20060
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-1BC2, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20062
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-1BD1, TCL = 7.72kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-1BD1, TCL = 7.72kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20064
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-2BA1, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20066
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-2BA2, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20068
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-2BB1, TCL = 10.12kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20070
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-2BC1, TCL = 10.15kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20072
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(27-28, 31-38)-3BB1, TCL = 11.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(27-28, 31-38)-3BB1, TCL = 11.42kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20074
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/389-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(29-30)-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(29-30)-1BD1, TCL = 7.89kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20076
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5250"
          }
        },
        {
          "id": "2 - Main/389-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(29-30)-1BF1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(29-30)-1BF1, TCL = 7.89kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20078
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5250"
          }
        },
        {
          "id": "2 - Main/389-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(29-30)-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(29-30)-2BB1, TCL = 10.56kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20080
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5250"
          }
        },
        {
          "id": "2 - Main/389-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(29-30)-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(29-30)-2BC1, TCL = 10.52kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20082
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,250.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5250"
          }
        },
        {
          "id": "2 - Main/389-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-1BA1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20084
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-1BC1, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20086
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-1BC2, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20088
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/389-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-1BD1, TCL = 7.72kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-1BD1, TCL = 7.72kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/90",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20090
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/390",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 189000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/390-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-2BA1, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/390-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-2BA2, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/390-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-2BB1, TCL = 10.12kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/390-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-2BC1, TCL = 10.15kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/390-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-(39-49)-3BB1, TCL = 11.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-(39-49)-3BB1, TCL = 11.42kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "11",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "28,875.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-28875"
          }
        },
        {
          "id": "2 - Main/390-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-01-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-01-1BD1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-01-1BE1, TCL = 7.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-01-1BE1, TCL = 7.92kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-01-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-01-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-01-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-01-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-01-LL01, TCL = 7.67kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-01-LL01, TCL = 7.67kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-02-LL01, TCL = 7.28kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-02-LL01, TCL = 7.28kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-03-EXT, TCL = 10kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-03-EXT, TCL = 10kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-03-LL01, TCL = 18.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-03-LL01, TCL = 18.73kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20127
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/390-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-06-LL01, TCL = 10.78kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-06-LL01, TCL = 10.78kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-09-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-09-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-12-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-12-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20133
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-15-LL01, TCL = 15.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-15-LL01, TCL = 15.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-18-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-18-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-21-LL01, TCL = 26.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-21-LL01, TCL = 26.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-24-LL01, TCL = 20.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-24-LL01, TCL = 20.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-27-LL01, TCL = 12.21kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-27-LL01, TCL = 12.21kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/390-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-29-LL01, TCL = 22.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-29-LL01, TCL = 22.99kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/91",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20145
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/391",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/391-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-32-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-32-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20158
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-35-LL01, TCL = 15.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-35-LL01, TCL = 15.15kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20160
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-38-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-38-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20162
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-41-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-41-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20164
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-44-LL01, TCL = 15.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-44-LL01, TCL = 15.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20166
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-47-LL01, TCL = 17.16kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-47-LL01, TCL = 17.16kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20168
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-50-6B1, TCL = 22.32kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-50-6B1, TCL = 22.32kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20170
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-50-6B2, TCL = 11.05kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-50-6B2, TCL = 11.05kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20172
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-50-LL01, TCL = 21.75kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-50-LL01, TCL = 21.75kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20174
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,625.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2625"
          }
        },
        {
          "id": "2 - Main/391-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-B1-LL01, TCL = 14.94kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-B1-LL01, TCL = 14.94kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20176
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-B2-LL01, TCL = 12.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-B2-LL01, TCL = 12.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20178
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-GF-LL01, TCL = 8.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-GF-LL01, TCL = 8.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20180
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-GF-LL02, TCL = 14.05kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-GF-LL02, TCL = 14.05kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20182
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L02-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L02-1BD1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20184
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L02-1BE1, TCL = 7.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L02-1BE1, TCL = 7.92kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20186
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L02-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L02-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20188
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L02-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L02-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20190
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L02-3BB1, TCL = 11.79kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L02-3BB1, TCL = 11.79kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20192
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-1BA1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-1BA1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20194
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-1BD1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20196
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20198
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/391-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/92",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20200
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/392",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 553875,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/392-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-3BB1, TCL = 11.79kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-3BB1, TCL = 11.79kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T1-L03-3BD1, TCL = 11.62kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T1-L03-3BD1, TCL = 11.62kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-1BA1, TCL = 7.73kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-1BB1, TCL = 7.73kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-1BC1, TCL = 7.68kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20221
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-1BC2, TCL = 7.68kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20223
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-2BA1, TCL = 10.13kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20225
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-2BA2, TCL = 10.13kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20227
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-2BB1, TCL = 10.12kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20229
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-2BC1, TCL = 10.15kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20231
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(04-12)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(04-12)-3BA1, TCL = 11.24kW",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 23625,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20233
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "9",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "23,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-1BA1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-1BB1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20237
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-1BC1, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-1BC2, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-2BA1, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-2BA2, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-2BB1, TCL = 10.12kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-2BC1, TCL = 10.15kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(13-24)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(13-24)-3BA1, TCL = 11.24kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "31,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-1BA1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/392-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-1BB1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/93",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/393",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 498750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/393-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-1BC1, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20268
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-1BC2, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20270
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-2BA1, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20272
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-2BA2, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20274
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-2BB1, TCL = 10.12kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20276
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-2BC1, TCL = 10.15kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(25-28, 31-36)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(25-28, 31-36)-3BA1, TCL = 11.24kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20280
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "26,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(29-30)-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(29-30)-2BB1, TCL = 10.56kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20282
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(29-30)-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(29-30)-2BC1, TCL = 10.52kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(29-30)-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(29-30)-3BA1, TCL = 11.63kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20286
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-1BA1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-1BB1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-1BC1, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20292
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-1BC2, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20294
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-"
          }
        },
        {
          "id": "2 - Main/393-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-2BA1, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-2BA2, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20298
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-2BB1, TCL = 10.12kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20300
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-2BC1, TCL = 10.15kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20302
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(37-47)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(37-47)-3BA1, TCL = 11.24kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "28,875.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(49-53)-3BC1, TCL = 11.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(49-53)-3BC1, TCL = 11.89kW",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 13125,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20306
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,125.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(49-53)-4BA1, TCL = 26.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(49-53)-4BA1, TCL = 26.31kW",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 13125,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20308
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,125.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/393-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(49-53)-4BA2, TCL = 26.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(49-53)-4BA2, TCL = 26.31kW",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 13125,
          "amount_state": "number",
          "printed_page": "2/R/94",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20310
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,125.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/394",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 73500,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/394-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(54-57)-4BB1, TCL = 27.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(54-57)-4BB1, TCL = 27.92kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-(54-57)-4BB2, TCL = 27.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-(54-57)-4BB2, TCL = 27.92kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-01-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-01-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-01-1BG1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-01-1BG1, TCL = 7.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20332
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-01-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-01-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20334
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-01-LL01, TCL = 7.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-01-LL01, TCL = 7.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20336
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-01-LL02, TCL = 4.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-01-LL02, TCL = 4.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20338
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-02-LL01, TCL = 7.28kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-02-LL01, TCL = 7.28kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20340
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-02-LL02, TCL = 5.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-02-LL02, TCL = 5.12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20342
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-02-LL03, TCL = 2.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-02-LL03, TCL = 2.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20344
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-03-KDCB",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-03-KDCB",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20346
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-03-LL01, TCL = 22.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-03-LL01, TCL = 22.13kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20348
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-03-LL02, TCL = 15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-03-LL02, TCL = 15kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20350
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-06-LL01, TCL = 14.81kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-06-LL01, TCL = 14.81kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20352
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-09-LL01, TCL = 11.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-09-LL01, TCL = 11.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20354
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-12-LL01, TCL = 14.21kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-12-LL01, TCL = 14.21kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20356
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-15-LL01, TCL = 14.8kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-15-LL01, TCL = 14.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20358
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-18-LL01, TCL = 11.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-18-LL01, TCL = 11.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20360
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-21-LL01, TCL = 14.21kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-21-LL01, TCL = 14.21kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20362
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-24-LL01, TCL = 11.6kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-24-LL01, TCL = 11.6kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20364
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-27-LL01, TCL = 12.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-27-LL01, TCL = 12.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20366
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/394-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-29-LL01, TCL = 20.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-29-LL01, TCL = 20.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/95",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20368
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/395",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/395-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-32-LL01, TCL = 10.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-32-LL01, TCL = 10.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-35-LL01, TCL = 13.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-35-LL01, TCL = 13.31kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-38-LL01, TCL = 10.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-38-LL01, TCL = 10.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-41-LL01, TCL = 12.8kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-41-LL01, TCL = 12.8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-44-LL01, TCL = 14.9kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-44-LL01, TCL = 14.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-47-LL01, TCL = 5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-47-LL01, TCL = 5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-1BA1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-1BA1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-3BA1, TCL = 11.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-48-LL01, TCL = 12.58kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-48-LL01, TCL = 12.58kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-50-LL01, TCL = 14.39kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-50-LL01, TCL = 14.39kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-53-LL01, TCL = 14.9kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-53-LL01, TCL = 14.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-56-LL01, TCL = 16.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-56-LL01, TCL = 16.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-58-6B1, TCL = 15.01kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-58-6B1, TCL = 15.01kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-58-6B2, TCL = 19.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-58-6B2, TCL = 19.36kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-59-LL01, TCL = 9.09kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-59-LL01, TCL = 9.09kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-B1-LL01, TCL = 14.93kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-B1-LL01, TCL = 14.93kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20419
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-B1-LL02, TCL = 6.19kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-B1-LL02, TCL = 6.19kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20421
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/395-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-B2-LL01, TCL = 11.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-B2-LL01, TCL = 11.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/96",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20423
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/396",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 133875,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/396-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-B2-LL02, TCL = 6.37kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-B2-LL02, TCL = 6.37kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20436
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-GF-LL01, TCL = 21.77kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-GF-LL01, TCL = 21.77kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20438
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-GF-LL02, TCL = 6.96kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-GF-LL02, TCL = 6.96kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20440
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-GF-LV01, TCL = 7.17kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-GF-LV01, TCL = 7.17kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20442
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-GF-SS-01, TCL = 1.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-GF-SS-01, TCL = 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20444
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-GF-WF1, TCL = 21kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-GF-WF1, TCL = 21kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20446
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L02-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L02-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20448
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L02-1BC1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L02-1BC1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20450
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L02-1BC2, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L02-1BC2, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20452
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L02-1BG1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L02-1BG1, TCL = 7.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20454
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L02-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L02-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20456
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-1BA1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-1BA1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20458
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20460
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-1BC1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-1BC1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20462
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-1BC2, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-1BC2, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20464
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20466
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-2BA2, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-2BA2, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20468
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-L03-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-L03-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20470
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T2-B1-WF1, TCL=8kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T2-B1-WF1, TCL=8kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20472
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-1BA1, TCL = 7.73kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20474
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-1BB1, TCL = 7.73kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20476
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-1BC1, TCL = 7.68kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20478
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/396-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-1BC2, TCL = 7.68kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/97",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20480
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/397",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 598500,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/397-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-2BA1, TCL = 10.13kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-2BA2, TCL = 10.13kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-2BB1, TCL = 10.12kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-2BC1, TCL = 10.15kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20499
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(04-11)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(04-11)-3BA1, TCL = 11.24kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20501
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "21,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-1BA1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-1BB1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20505
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-1BC1, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-1BC2, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20509
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-2BA1, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20511
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-2BA2, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20513
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-2BB1, TCL = 10.12kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-2BC1, TCL = 10.15kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20517
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(12-23)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(12-23)-3BA1, TCL = 11.24kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20519
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "31,500.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-1BA1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-1BB1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20523
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-1BC1, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-1BC2, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20527
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-2BA1, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20529
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-2BA2, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-2BB1, TCL = 10.12kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20533
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/397-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-2BC1, TCL = 10.15kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/98",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/398",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 506625,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/398-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(24-28, 31-35)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(24-28, 31-35)-3BA1, TCL = 11.24kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20551
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-1BA1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20553
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-1BB1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20555
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-1BC1, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20557
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-1BC2, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-2BA1, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-2BA2, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-2BB1, TCL = 10.12kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-2BC1, TCL = 10.15kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(36-45)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(36-45)-3BA1, TCL = 11.24kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-1BA1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-1BB1, TCL = 7.73kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-1BC1, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-1BC2, TCL = 7.68kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-2BA1, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-2BA2, TCL = 10.13kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-2BB1, TCL = 10.12kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-2BC1, TCL = 10.15kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-(46-55)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-(46-55)-3BA1, TCL = 11.24kW",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 26250,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "26,250.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-01-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-01-1BD1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-01-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-01-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/398-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-01-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-01-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/99",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/399",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 57750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/399-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-01-LL01, TCL = 7.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-01-LL01, TCL = 7.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-02-LL01, TCL = 8.78kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-02-LL01, TCL = 8.78kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-03-LL01, TCL = 21.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-03-LL01, TCL = 21.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20609
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-06-LL01, TCL = 15.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-06-LL01, TCL = 15.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20611
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-09-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-09-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-12-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-12-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-15-LL01, TCL = 12.26kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-15-LL01, TCL = 12.26kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20617
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-18-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-18-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20619
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-21-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-21-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-24-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-24-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20623
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-27-LL01, TCL = 11.17kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-27-LL01, TCL = 11.17kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20625
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-29-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-29-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20627
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-29-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-29-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20629
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-29-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-29-3BA1, TCL = 11.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20631
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-29-LL01, TCL = 24.43kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-29-LL01, TCL = 24.43kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20633
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-32-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-32-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20635
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-35-LL01, TCL = 15.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-35-LL01, TCL = 15.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20637
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-38-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-38-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20639
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-41-LL01, TCL = 11.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-41-LL01, TCL = 11.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20641
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-44-LL01, TCL = 15.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-44-LL01, TCL = 15.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20643
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-47-LL01, TCL = 16.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-47-LL01, TCL = 16.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20645
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/399-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-50-LL01, TCL = 21.29kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-50-LL01, TCL = 21.29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/100",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20647
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/400",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 68250,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/400-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-53-LL01, TCL = 14.19kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-53-LL01, TCL = 14.19kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20659
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-56-6B1, TCL = 25.34kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-56-6B1, TCL = 25.34kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20661
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-56-6B2, TCL = 11.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-56-6B2, TCL = 11.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-56-LL01, TCL = 16.72kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-56-LL01, TCL = 16.72kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20665
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-57-LL01, TCL = 15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-57-LL01, TCL = 15kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-58-LL01, TCL = 17.21kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-58-LL01, TCL = 17.21kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20669
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,625.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-B1-LL01, TCL = 16.34kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-B1-LL01, TCL = 16.34kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20671
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-B2-LL01, TCL = 13.95kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-B2-LL01, TCL = 13.95kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20673
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-GF-LL01, TCL = 6.82kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-GF-LL01, TCL = 6.82kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20675
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-GF-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20677
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L02-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L02-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20679
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L02-1BD1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L02-1BD1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L02-1BG1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L02-1BG1, TCL = 7.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L02-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L02-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20685
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L02-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L02-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20687
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-1BA1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-1BA1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20689
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20691
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20693
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20695
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-3BA1, TCL = 11.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20697
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T3-L03-3BD1, TCL = 11.62kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T3-L03-3BD1, TCL = 11.62kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-GF-SS01, TCL = 1.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-GF-SS01, TCL = 1.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/400-X#2",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-1BA1, TCL = 7.73kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20703
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/400-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-1BB1, TCL = 7.73kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/101",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/401",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 493500,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/401-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-1BC1, TCL = 7.68kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20717
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-1BC2, TCL = 7.68kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20719
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-2BA1, TCL = 10.13kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20721
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-2BA2, TCL = 10.13kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20723
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-2BB1, TCL = 10.12kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20725
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-2BC1, TCL = 10.15kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20727
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(04-05)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(04-05)-3BA1, TCL = 11.24kW",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 5250,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20729
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,250.00",
            "[S]": "TRUE",
            "[T]": "5250"
          }
        },
        {
          "id": "2 - Main/401-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-1BA1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20731
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-1BB1, TCL = 7.73kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20733
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-1BC1, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20735
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-1BC2, TCL = 7.68kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20737
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-2BA1, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20739
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-2BA2, TCL = 10.13kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20741
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-2BB1, TCL = 10.12kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20743
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-2BC1, TCL = 10.15kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20745
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(06-17)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(06-17)-3BA1, TCL = 11.24kW",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20747
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "31,500.00",
            "[S]": "TRUE",
            "[T]": "31500"
          }
        },
        {
          "id": "2 - Main/401-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-1BA1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20749
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/401-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-1BB1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20751
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/401-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-1BC1, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20753
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/401-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-1BC2, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20755
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/401-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-2BA1, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20757
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/401-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-2BA2, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/102",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20759
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/402",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 546000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/402-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-2BB1, TCL = 10.12kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20771
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-2BC1, TCL = 10.15kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20773
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(18-28)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(18-28)-3BA1, TCL = 11.24kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20775
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-1BA1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-1BB1, TCL = 7.73kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-1BC1, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-1BC2, TCL = 7.68kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20783
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-2BA1, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-2BA2, TCL = 10.13kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-2BB1, TCL = 10.12kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-2BC1, TCL = 10.15kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20791
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(31-41)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(31-41)-3BA1, TCL = 11.24kW",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 28875,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20793
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "28,875.00",
            "[S]": "TRUE",
            "[T]": "28875"
          }
        },
        {
          "id": "2 - Main/402-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-1BA1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-1BA1, TCL = 7.73kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-1BB1, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-1BB1, TCL = 7.73kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-1BC1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-1BC1, TCL = 7.68kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-1BC2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-1BC2, TCL = 7.68kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20801
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-2BA1, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-2BA1, TCL = 10.13kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20803
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-2BA2, TCL = 10.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-2BA2, TCL = 10.13kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20805
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-2BB1, TCL = 10.12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-2BB1, TCL = 10.12kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20807
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-2BC1, TCL = 10.15kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-2BC1, TCL = 10.15kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(42-49)-3BA1, TCL = 11.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(42-49)-3BA1, TCL = 11.24kW",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,000.00",
            "[S]": "TRUE",
            "[T]": "21000"
          }
        },
        {
          "id": "2 - Main/402-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(50-53)-4BB2, TCL = 28.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(50-53)-4BB2, TCL = 28.99kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/103",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,500.00",
            "[S]": "TRUE",
            "[T]": "10500"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/403",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 65625,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/403-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-(50-53)-4BB1, TCL = 28.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-(50-53)-4BB1, TCL = 28.99kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20825
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,500.00",
            "[S]": "TRUE",
            "[T]": "10500"
          }
        },
        {
          "id": "2 - Main/403-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-01-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-01-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20827
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-01-1BG1, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-01-1BG1, TCL = 7.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20829
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-01-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-01-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20831
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-01-2BA2, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-01-2BA2, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-01-LL01, TCL = 19.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-01-LL01, TCL = 19.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-02-GYM, TCL = 7kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-02-GYM, TCL = 7kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-02-LL01, TCL = 8.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-02-LL01, TCL = 8.13kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-1BC1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-1BC1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-1BC2, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-1BC2, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-2BA2, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-2BA2, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-2BC1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-2BC1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-LL01, TCL = 23.02kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-LL01, TCL = 23.02kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20853
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-LL02, TCL = 12.23kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-LL02, TCL = 12.23kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/403-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-06-LL01, TCL = 16.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-06-LL01, TCL = 16.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20857
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/403-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-09-LL01, TCL = 13.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-09-LL01, TCL = 13.36kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20859
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/403-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-12-LL01, TCL = 15.96kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-12-LL01, TCL = 15.96kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20861
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/403-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-15-LL01, TCL = 16.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-15-LL01, TCL = 16.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20863
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/403-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-18-LL01, TCL = 19.28kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-18-LL01, TCL = 19.28kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20865
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/403-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-21-LL01, TCL = 14.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-21-LL01, TCL = 14.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/104",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20867
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/404",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 60375,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/404-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-24-LL01, TCL = 13.96kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-24-LL01, TCL = 13.96kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20879
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-27-LL01, TCL = 13.62kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-27-LL01, TCL = 13.62kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20881
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-29-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-29-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20883
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-29-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-29-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20885
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-29-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-29-3BA1, TCL = 11.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20887
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-29-LL01, TCL = 26.45kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-29-LL01, TCL = 26.45kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20889
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-30-2BB1, TCL = 10.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-30-2BB1, TCL = 10.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20891
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-30-2BC1, TCL = 10.52kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-30-2BC1, TCL = 10.52kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20893
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-30-3BA1, TCL = 11.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-30-3BA1, TCL = 11.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20895
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-32-LL01, TCL = 13.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-32-LL01, TCL = 13.36kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20897
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-35-LL01, TCL = 16.66kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-35-LL01, TCL = 16.66kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20899
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-38-LL01, TCL = 16.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-38-LL01, TCL = 16.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20901
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-41-LL01, TCL = 12.36kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-41-LL01, TCL = 12.36kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20903
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-44-LL01, TCL = 15.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-44-LL01, TCL = 15.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20905
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-47-LL01, TCL = 16.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-47-LL01, TCL = 16.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20907
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-50-LL01, TCL = 11.66kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-50-LL01, TCL = 11.66kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20909
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-53-LL01, TCL = 13.92kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-53-LL01, TCL = 13.92kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20911
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-54-6B1, TCL = 14.64kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-54-6B1, TCL = 14.64kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20913
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-54-6B2, TCL = 19.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-54-6B2, TCL = 19.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20915
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-55-LL01, TCL = 7.82kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-55-LL01, TCL = 7.82kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20917
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-56-LL01, TCL = 7.82kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-56-LL01, TCL = 7.82kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,625.00",
            "[S]": "TRUE",
            "[T]": "2625"
          }
        },
        {
          "id": "2 - Main/404-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-B1-LL01, TCL = 7.22kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-B1-LL01, TCL = 7.22kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20921
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/404-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-B1-LL02, TCL = 7.25kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-B1-LL02, TCL = 7.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/105",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20923
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/405",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 63525,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/405-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-B2-LL01, TCL = 7.56kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-B2-LL01, TCL = 7.56kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20935
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-B2-LL02, TCL = 7.25kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-B2-LL02, TCL = 7.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20937
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "2,625.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-GF-LL01, TCL = 19.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-GF-LL01, TCL = 19.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20939
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-GF-LV01, TCL = 6.86kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-GF-LV01, TCL = 6.86kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-1BB1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-1BB1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20943
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-1BC1, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-1BC1, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20945
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-1BC2, TCL = 7.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-1BC2, TCL = 7.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20947
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-1BG2, TCL = 7.68kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-1BG2, TCL = 7.68kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20949
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-2BA1, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-2BA1, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-L02-2BA2, TCL = 10.47kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-L02-2BA2, TCL = 10.47kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20953
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Distribution board"
          ],
          "own_description": "DB-T4-03-1BB2, TCL = 7.73kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Distribution board — DB-T4-03-1BB2, TCL = 7.73kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2625,
          "amount_aed": 2625,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20955
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,625.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-L#2",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1&3-GF-LV 01, TCL = 4.2kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1&3-GF-LV 01, TCL = 4.2kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20959
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-01-LL01, TCL = 17.78kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-01-LL01, TCL = 17.78kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20961
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-02-LL01, TCL = 17.78kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-02-LL01, TCL = 17.78kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-03-LL01, TCL = 3.46kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-03-LL01, TCL = 3.46kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/405-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-04-LL01, TCL = 5.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-04-LL01, TCL = 5.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-07-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-07-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20969
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-10-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-10-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-13-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-13-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20973
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-16-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-16-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20975
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-19-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-19-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20977
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/405-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-22-LL01, TCL = 3.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-22-LL01, TCL = 3.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/106",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20979
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/406",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/406-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-25-LL01, TCL = 4.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-25-LL01, TCL = 4.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20991
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-28-LL01, TCL = 1.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-28-LL01, TCL = 1.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20993
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-29-LL01, TCL = 9.06kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-29-LL01, TCL = 9.06kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20995
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-31-LL01, TCL = 5.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-31-LL01, TCL = 5.31kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20997
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-34-LL01, TCL = 5.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-34-LL01, TCL = 5.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 20999
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-37-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-37-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21001
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-40-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-40-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21003
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-43-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-43-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21005
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-46-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-46-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21007
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-49-LL01, TCL = 3.89kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-49-LL01, TCL = 3.89kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21009
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-51-LL01, TCL = 5.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-51-LL01, TCL = 5.00kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21011
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/406-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-B1-LL01, TCL = 1.33kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-B1-LL01, TCL = 1.33kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21013
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-B2-LL01, TCL = 4.13kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-B2-LL01, TCL = 4.13kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21015
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-GF-LL01, TCL = 12.65kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-GF-LL01, TCL = 12.65kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21017
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T1-GF-MTR, TCL = 12.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T1-GF-MTR, TCL = 12.00kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21019
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-01-LL01, TCL = 8.48kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-01-LL01, TCL = 8.48kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21021
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-01-LL02, TCL = 14.3kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-01-LL02, TCL = 14.3kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21023
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-02-LL01, TCL = 8.48kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-02-LL01, TCL = 8.48kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21025
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-02-LL02, TCL = 20.93kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-02-LL02, TCL = 20.93kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21027
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-03-LL01, TCL = 2.35kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-03-LL01, TCL = 2.35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-04-LL01, TCL = 5.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-04-LL01, TCL = 5.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/406-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-07-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-07-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/107",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21033
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/407",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/407-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-10-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-10-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21045
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-13-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-13-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21047
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-16-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-16-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21049
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-19-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-19-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-22-LL01, TCL = 3.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-22-LL01, TCL = 3.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-25-LL01, TCL = 4.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-25-LL01, TCL = 4.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-28-LL01, TCL = 1.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-28-LL01, TCL = 1.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-29-LL01, TCL = 7.82kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-29-LL01, TCL = 7.82kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-31-LL01, TCL = 5.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-31-LL01, TCL = 5.31kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-34-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-34-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-37-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-37-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21065
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-40-LL01, TCL = 7.59kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-40-LL01, TCL = 7.59kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21067
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-43-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-43-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21069
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-46-LL01, TCL = 2.42kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-46-LL01, TCL = 2.42kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21071
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-48-LL01, TCL = 1.25kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-48-LL01, TCL = 1.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-49-LL01, TCL = 5.71kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-49-LL01, TCL = 5.71kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-52-LL01, TCL = 4.44kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-52-LL01, TCL = 4.44kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-55-LL01, TCL = 6.65kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-55-LL01, TCL = 6.65kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-59-LL01, TCL = 3.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-59-LL01, TCL = 3.99kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-B1-LL01, TCL = 1.38kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-B1-LL01, TCL = 1.38kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21083
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-B1-LL02, TCL = 2.4kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-B1-LL02, TCL = 2.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21085
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/407-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-B2-LL01, TCL = 3.99kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-B2-LL01, TCL = 3.99kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/108",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21087
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/408",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 75600,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/408-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-B2-LL02, TCL = 3.26kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-B2-LL02, TCL = 3.26kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21099
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-GF-ETS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-GF-ETS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21101
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-GF-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21103
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-GF-LV-01, TCL = 15.75kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-GF-LV-01, TCL = 15.75kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21105
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-GF-LL01, TCL=7.25kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-GF-LL01, TCL=7.25kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21107
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T2-GF-LL02, TCL=6.08kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T2-GF-LL02, TCL=6.08kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21109
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-01-LL01, TCL = 7.03kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-01-LL01, TCL = 7.03kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21111
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-02-LL01, TCL = 5.53kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-02-LL01, TCL = 5.53kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21113
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-03-LL01, TCL = 4.35kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-03-LL01, TCL = 4.35kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21115
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-04-LL01, TCL = 5.14kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-04-LL01, TCL = 5.14kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21117
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-07-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-07-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21119
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-10-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-10-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21121
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-13-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-13-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21123
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-16-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-16-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21125
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-19-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-19-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21127
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-22-LL01, TCL = 3.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-22-LL01, TCL = 3.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-25-LL01, TCL = 4.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-25-LL01, TCL = 4.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-28-LL01, TCL = 1.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-28-LL01, TCL = 1.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21133
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-29-LL01, TCL = 7.76kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-29-LL01, TCL = 7.76kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-31-LL01, TCL = 5.31kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-31-LL01, TCL = 5.31kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-34-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-34-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-37-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-37-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-Y",
          "item_code": "Y",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-40-LL01, TCL = 5.79kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-40-LL01, TCL = 5.79kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/408-Z",
          "item_code": "Z",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-43-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-43-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/109",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21145
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/409",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/409-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-46-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-46-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-49-LL01, TCL = 3.95kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-49-LL01, TCL = 3.95kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-52-LL01, TCL = 4.57kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-52-LL01, TCL = 4.57kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-57-LL01, TCL = 4.63kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-57-LL01, TCL = 4.63kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-59-LL01, TCL = 2.26kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-59-LL01, TCL = 2.26kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-B1-LL01, TCL = 1.28kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-B1-LL01, TCL = 1.28kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21167
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-B2-LL01, TCL = 5.4kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-B2-LL01, TCL = 5.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21169
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-GF-LL01, TCL = 14.69kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-GF-LL01, TCL = 14.69kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21171
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T3-GF-MTR, TCL = 12.00kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T3-GF-MTR, TCL = 12.00kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21173
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-01-LL01, TCL = 6.18kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-01-LL01, TCL = 6.18kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21175
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-02-LL01, TCL = 5.85kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-02-LL01, TCL = 5.85kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21177
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-03-LL01, TCL = 3.65kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-03-LL01, TCL = 3.65kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21179
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/409-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-04-LL01, TCL = 5.54kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-04-LL01, TCL = 5.54kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-07-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-07-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-10-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-10-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-13-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-13-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-16-LL01, TCL = 5.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-16-LL01, TCL = 5.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-19-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-19-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-22-LL01, TCL = 3.04kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-22-LL01, TCL = 3.04kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-25-LL01, TCL = 4.51kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-25-LL01, TCL = 4.51kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-28-LL01, TCL = 1.61kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-28-LL01, TCL = 1.61kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/409-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-29-LL01, TCL = 5.16kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-29-LL01, TCL = 5.16kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/110",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/410",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 133350,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/410-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-31-LL01, TCL = 4.71kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-31-LL01, TCL = 4.71kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-34-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-34-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-37-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-37-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-40-LL01, TCL = 6.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-40-LL01, TCL = 6.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-43-LL01, TCL = 3.84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-43-LL01, TCL = 3.84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-46-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-46-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21221
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-49-LL01, TCL = 5.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-49-LL01, TCL = 5.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21223
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-52-LL01, TCL = 3.24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-52-LL01, TCL = 3.24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21225
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-55-LL01, TCL = 8.43kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-55-LL01, TCL = 8.43kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21227
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/410-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-B1-LL01, TCL = 2.74kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-B1-LL01, TCL = 2.74kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21229
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-B2-LL01, TCL = 5.11kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-B2-LL01, TCL = 5.11kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21231
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-GF-LV03, TCL = 9.29kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-GF-LV03, TCL = 9.29kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21233
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency distribution board"
          ],
          "own_description": "EDB-T4-GF-LL01, TCL = 22.49kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency distribution board — EDB-T4-GF-LL01, TCL = 22.49kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible distribution board"
          ],
          "own_description": "UDB-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible distribution board — UDB-T1-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible distribution board"
          ],
          "own_description": "UDB-T2-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible distribution board — UDB-T2-GF-LV01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible distribution board"
          ],
          "own_description": "UDB-T4-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible distribution board — UDB-T4-GF-LV01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible distribution board"
          ],
          "own_description": "UDB-T4-GF-SEC-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible distribution board — UDB-T4-GF-SEC-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-CHWP, TCL = 84kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-CHWP, TCL = 84kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/410-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        },
        {
          "id": "2 - Main/410-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-FP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        },
        {
          "id": "2 - Main/410-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-JP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/111",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/411",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 724850,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/411-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-TP1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        },
        {
          "id": "2 - Main/411-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-29-TP2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        },
        {
          "id": "2 - Main/411-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-51-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-51-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "26,600.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-26600"
          }
        },
        {
          "id": "2 - Main/411-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 26600,
          "amount_aed": 26600,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21273
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "26,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T1-B2-LL01, TCL = 60kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T1-B2-LL01, TCL = 60kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 21000,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21275
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "21,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-29-CHWP, TCL = 105kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-29-CHWP, TCL = 105kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-29-FP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21279
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-29-JP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21281
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-29-TP1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21283
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-29-TP2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21285
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-59-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-59-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21287
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-RF-FAHU1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-RF-FAHU1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-48-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-48-FP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-48-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-48-JP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-48-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-48-TP1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-48-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-48-TP2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "36,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-B1-CHWP1, TCL = 240kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-B1-CHWP1, TCL = 240kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21299
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "36,750.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-B1-CHWP2, TCL = 184kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-B1-CHWP2, TCL = 184kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21301
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "36,750.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T2-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 36750,
          "amount_aed": 36750,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21303
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "36,750.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-29-CHWP, TCL = 79kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-29-CHWP, TCL = 79kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-29-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/411-X",
          "item_code": "X",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-29-FP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/112",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/412",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 795900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/412-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "B4.3: L29: MCC-T3-29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — B4.3: L29: MCC-T3-29-JP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-29-TP1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-29-TP2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-55-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-55-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "27,650.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21329
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "27,650.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T3-B2-LL01, TCL = 45kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T3-B2-LL01, TCL = 45kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 27650,
          "amount_aed": 27650,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21331
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "27,650.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-29-CHWP, TCL = 120kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-29-CHWP, TCL = 120kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21333
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-29-TP2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-29-TP2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21335
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-L29-FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-L29-FAHU",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21337
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-L29-FP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-L29-FP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21339
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-L29-JP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-L29-JP",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21341
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-L29-TP1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-L29-TP1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-RF-FAHU1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-RF-FAHU1",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/412-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21347
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "42,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Motor control center"
          ],
          "own_description": "MCC-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Motor control center — MCC-T4-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21349
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "42,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-48-T2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-48-T2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21353
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "42,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T1-30-FAN, TCL = 24kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T1-30-FAN, TCL = 24kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21355
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "42,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-42000"
          }
        },
        {
          "id": "2 - Main/412-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T1-51-FAN, TCL = 16kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T1-51-FAN, TCL = 16kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21357
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "42,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-42000"
          }
        },
        {
          "id": "2 - Main/412-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T1-GF-FAN-01, TCL = 104kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T1-GF-FAN-01, TCL = 104kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21359
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-01-FAN1, TCL = 104kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-01-FAN1, TCL = 104kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21361
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/412-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-02-FAN1, TCL = 120kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-02-FAN1, TCL = 120kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/113",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21363
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/413",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1176000,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/413-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-30-FAN, TCL = 22.9kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-30-FAN, TCL = 22.9kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21375
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "42,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-59-FAN, TCL = 16.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-59-FAN, TCL = 16.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21377
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "42,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-B1-FAN1, TCL = 104kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-B1-FAN1, TCL = 104kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21379
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "42,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T2-GF-FAN-02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T2-GF-FAN-02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T3-01-FAN1, TCL = 120kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T3-01-FAN1, TCL = 120kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T3-02-FAN1, TCL = 12kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T3-02-FAN1, TCL = 12kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T3-30-FAN, TCL = 23.40kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T3-30-FAN, TCL = 23.40kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21387
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "42,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T3-57-FAN, TCL = 16.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T3-57-FAN, TCL = 16.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21389
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "42,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T3-57-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T3-57-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21391
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "42,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T4-01-FAN1, TCL = 120kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T4-01-FAN1, TCL = 120kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21393
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T4-30-FAN, TCL = 23.4kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T4-30-FAN, TCL = 23.4kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21395
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/413-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T4-55-FAN, TCL = 16.5kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T4-55-FAN, TCL = 16.5kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "42,000.00",
            "[S]": "TRUE",
            "[T]": "42000"
          }
        },
        {
          "id": "2 - Main/413-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency motor control center"
          ],
          "own_description": "EMCC-T4-GF-FAN1, TCL = 141kW",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency motor control center — EMCC-T4-GF-FAN1, TCL = 141kW",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 42000,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Capacitor bank"
          ],
          "own_description": "300kVAR capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Capacitor bank — 300kVAR capacitor bank",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 40000,
          "amount_aed": 360000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/413-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Capacitor bank"
          ],
          "own_description": "350kVAR capacitor bank",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Capacitor bank — 350kVAR capacitor bank",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 45000,
          "amount_aed": 270000,
          "amount_state": "number",
          "printed_page": "2/R/114",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "270,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/414",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 4049580,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/414-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Stand-by diesel generator set including; alternator, automatic voltage regulator, engine, fuel system including pipes and fittings, day tanks, storage tanks, lubrication, starting system, exhaust system, ventilation, attenuator with louver and cooling system, guards, control gear, switchgear, safety system and enclosure, acoustic treatment, accessories and all ancillary works as necessary"
          ],
          "own_description": "1000kVA Generator set",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Stand-by diesel generator set including; alternator, automatic voltage regulator, engine, fuel system including pipes and fittings, day tanks, storage tanks, lubrication, starting system, exhaust system, ventilation, attenuator with louver and cooling system, guards, control gear, switchgear, safety system and enclosure, acoustic treatment, accessories and all ancillary works as necessary — 1000kVA Generator set",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 945000,
          "amount_aed": 945000,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "945,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Stand-by diesel generator set including; alternator, automatic voltage regulator, engine, fuel system including pipes and fittings, day tanks, storage tanks, lubrication, starting system, exhaust system, ventilation, attenuator with louver and cooling system, guards, control gear, switchgear, safety system and enclosure, acoustic treatment, accessories and all ancillary works as necessary"
          ],
          "own_description": "1500kVA Generator set",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Stand-by diesel generator set including; alternator, automatic voltage regulator, engine, fuel system including pipes and fittings, day tanks, storage tanks, lubrication, starting system, exhaust system, ventilation, attenuator with louver and cooling system, guards, control gear, switchgear, safety system and enclosure, acoustic treatment, accessories and all ancillary works as necessary — 1500kVA Generator set",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1417500,
          "amount_aed": 1417500,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,417,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Generator panel"
          ],
          "own_description": "GEN 2-GF-LV03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Generator panel — GEN 2-GF-LV03",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Generator panel"
          ],
          "own_description": "GEN-T1&3-GF-LV01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Generator panel — GEN-T1&3-GF-LV01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Uninterruptible power supply"
          ],
          "own_description": "5kVA UPS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Uninterruptible power supply — 5kVA UPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 35000,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Energy monitoring unit"
          ],
          "own_description": "Energy monitoring unit (EMU)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Energy monitoring unit — Energy monitoring unit (EMU)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 22400,
          "amount_aed": 22400,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21441
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "KWh / CT meters; including termination and kWh meter base as necessary (kWh meter by DEWA)"
          ],
          "own_description": "DEWA CT meter",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — KWh / CT meters; including termination and kWh meter base as necessary (kWh meter by DEWA) — DEWA CT meter",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 30000,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "KWh / CT meters; including termination and kWh meter base as necessary (kWh meter by DEWA)"
          ],
          "own_description": "DEWA kWh meter",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — KWh / CT meters; including termination and kWh meter base as necessary (kWh meter by DEWA) — DEWA kWh meter",
          "quantity": 1735,
          "unit": "Nr.",
          "rate_aed": 525,
          "amount_aed": 910875,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21447
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "62",
            "Tower 1 [E]": "406",
            "Tower 2 [F]": "415",
            "Tower 3 [G]": "440",
            "Tower 4 [H]": "412",
            "TOTAL QTY [I]": "1,735",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,550.00",
            "TOWER 1 [O]": "213,150.00",
            "TOWER 2 [P]": "217,875.00",
            "TOWER 3 [Q]": "231,000.00",
            "TOWER 4 [R]": "216,300.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/414-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "40A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 40A MCCB tap-off",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1270,
          "amount_aed": 5080,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21451
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,540.00",
            "TOWER 1 [O]": "2,540.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-2540"
          }
        },
        {
          "id": "2 - Main/414-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "63A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 63A MCCB tap-off",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 16000,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21453
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,000.00",
            "TOWER 3 [Q]": "4,000.00",
            "TOWER 4 [R]": "4,000.00",
            "[S]": "TRUE",
            "[T]": "4000"
          }
        },
        {
          "id": "2 - Main/414-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "80A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 80A MCCB tap-off",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 2250,
          "amount_aed": 6750,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21455
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/414-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "100A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 100A MCCB tap-off",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 32500,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21457
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "15,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,000.00",
            "[S]": "TRUE",
            "[T]": "10000"
          }
        },
        {
          "id": "2 - Main/414-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "125A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 125A MCCB tap-off",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 3125,
          "amount_aed": 46875,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21459
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,250.00",
            "TOWER 1 [O]": "3,125.00",
            "TOWER 2 [P]": "15,625.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "21,875.00",
            "[S]": "TRUE",
            "[T]": "18750"
          }
        },
        {
          "id": "2 - Main/414-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "160A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 160A MCCB tap-off",
          "quantity": 173,
          "unit": "Nr.",
          "rate_aed": 3200,
          "amount_aed": 553600,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "47",
            "Tower 4 [H]": "37",
            "TOTAL QTY [I]": "173",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "144,000.00",
            "TOWER 2 [P]": "137,600.00",
            "TOWER 3 [Q]": "150,400.00",
            "TOWER 4 [R]": "118,400.00",
            "[S]": "TRUE",
            "[T]": "-25600"
          }
        },
        {
          "id": "2 - Main/414-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "200A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 200A MCCB tap-off",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "2/R/115",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,000.00",
            "TOWER 1 [O]": "4,000.00",
            "TOWER 2 [P]": "4,000.00",
            "TOWER 3 [Q]": "4,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/415",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 208280,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/415-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "225A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 225A MCCB tap-off",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4000,
          "amount_aed": 8000,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,000.00",
            "TOWER 2 [P]": "4,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4000"
          }
        },
        {
          "id": "2 - Main/415-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "250A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 250A MCCB tap-off",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE",
            "[T]": "5000"
          }
        },
        {
          "id": "2 - Main/415-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "300A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 300A MCCB tap-off",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "12,000.00",
            "TOWER 4 [R]": "6,000.00",
            "[S]": "TRUE",
            "[T]": "6000"
          }
        },
        {
          "id": "2 - Main/415-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "400A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 400A MCCB tap-off",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 13600,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "13,600.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "500A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 500A MCCB tap-off",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 7500,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,500.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7500"
          }
        },
        {
          "id": "2 - Main/415-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Tap-off unit"
          ],
          "own_description": "630A MCCB tap-off",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Tap-off unit — 630A MCCB tap-off",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 7800,
          "amount_aed": 15600,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "7,800.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "7,800.00",
            "[S]": "TRUE",
            "[T]": "7800"
          }
        },
        {
          "id": "2 - Main/415-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "20A SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 20A SP isolator",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 6240,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "11",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,600.00",
            "TOWER 2 [P]": "1,760.00",
            "TOWER 3 [Q]": "1,280.00",
            "TOWER 4 [R]": "1,600.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "20A SPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 20A SPN isolator",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "20A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 20A TP isolator",
          "quantity": 50,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 17500,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21491
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "10",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "2,100.00",
            "GF & PODIUM [N]": "3,850.00",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "3,500.00",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "1,750.00",
            "[S]": "TRUE",
            "[T]": "-1400"
          }
        },
        {
          "id": "2 - Main/415-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "20A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 20A TP isolator, fire rated",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 3850,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "700.00",
            "TOWER 2 [P]": "1,050.00",
            "TOWER 3 [Q]": "1,050.00",
            "TOWER 4 [R]": "1,050.00",
            "[S]": "TRUE",
            "[T]": "350"
          }
        },
        {
          "id": "2 - Main/415-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "20A TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 20A TPN isolator",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 1400,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21495
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "350.00",
            "TOWER 4 [R]": "1,050.00",
            "[S]": "TRUE",
            "[T]": "1050"
          }
        },
        {
          "id": "2 - Main/415-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "32A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 32A TP isolator",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 5440,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21497
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,210.00",
            "TOWER 1 [O]": "1,190.00",
            "TOWER 2 [P]": "1,020.00",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "680.00",
            "[S]": "TRUE",
            "[T]": "-510"
          }
        },
        {
          "id": "2 - Main/415-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "32A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 32A TP isolator, fire rated",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 1700,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21499
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "340.00",
            "TOWER 2 [P]": "680.00",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "340.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "32A TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 32A TPN isolator",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 1190,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21501
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "680.00",
            "TOWER 4 [R]": "510.00",
            "[S]": "TRUE",
            "[T]": "510"
          }
        },
        {
          "id": "2 - Main/415-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "32A TPN isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 32A TPN isolator, fire rated",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 170,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21503
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "170.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "40A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 40A TP isolator",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 13020,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21505
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "7,140.00",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,260.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,260.00",
            "[S]": "TRUE",
            "[T]": "1260"
          }
        },
        {
          "id": "2 - Main/415-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "40A TP isolator, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 40A TP isolator, weatherproof",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 12600,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,080.00",
            "TOWER 1 [O]": "840.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "840.00",
            "TOWER 4 [R]": "840.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "63A SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 63A SP isolator",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 3400,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21509
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,700.00",
            "[S]": "TRUE",
            "[T]": "1700"
          }
        },
        {
          "id": "2 - Main/415-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "63A TP  isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 63A TP  isolator",
          "quantity": 69,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 58650,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21511
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "1,700.00",
            "GF & PODIUM [N]": "16,150.00",
            "TOWER 1 [O]": "11,050.00",
            "TOWER 2 [P]": "10,200.00",
            "TOWER 3 [Q]": "11,050.00",
            "TOWER 4 [R]": "8,500.00",
            "[S]": "TRUE",
            "[T]": "-2550"
          }
        },
        {
          "id": "2 - Main/415-V",
          "item_code": "V",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "63A TP isolator, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 63A TP isolator, weatherproof",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 1700,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21513
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/415-W",
          "item_code": "W",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "63A TPN isolator, explosion proof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 63A TPN isolator, explosion proof",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 3400,
          "amount_state": "number",
          "printed_page": "2/R/116",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/416",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1875300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/416-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "80A SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 80A SP isolator",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1250,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21527
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,250.00",
            "[S]": "TRUE",
            "[T]": "1250"
          }
        },
        {
          "id": "2 - Main/416-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "80A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 80A TP isolator",
          "quantity": 23,
          "unit": "Nr.",
          "rate_aed": 1250,
          "amount_aed": 28750,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21529
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "5,000.00",
            "GF & PODIUM [N]": "16,250.00",
            "TOWER 1 [O]": "3,750.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,750.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3750"
          }
        },
        {
          "id": "2 - Main/416-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "100A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 100A TP isolator",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 13500,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,050.00",
            "TOWER 1 [O]": "2,700.00",
            "TOWER 2 [P]": "2,700.00",
            "TOWER 3 [Q]": "1,350.00",
            "TOWER 4 [R]": "2,700.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/416-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "100A TP isolator, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 100A TP isolator, weatherproof",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1350,
          "amount_aed": 6750,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21533
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,350.00",
            "TOWER 2 [P]": "1,350.00",
            "TOWER 3 [Q]": "1,350.00",
            "TOWER 4 [R]": "2,700.00",
            "[S]": "TRUE",
            "[T]": "1350"
          }
        },
        {
          "id": "2 - Main/416-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "125A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 125A TP isolator",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 1690,
          "amount_aed": 32110,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "11,830.00",
            "TOWER 2 [P]": "10,140.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,140.00",
            "[S]": "TRUE",
            "[T]": "-1690"
          }
        },
        {
          "id": "2 - Main/416-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "160A TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 160A TP isolator",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21537
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "14,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,000.00",
            "TOWER 3 [Q]": "14,000.00",
            "TOWER 4 [R]": "2,000.00",
            "[S]": "TRUE",
            "[T]": "2000"
          }
        },
        {
          "id": "2 - Main/416-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "100A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 100A TP isolator, fire rated",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3830,
          "amount_aed": 3830,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21539
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,830.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/416-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "350A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 350A TP isolator, fire rated",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 4380,
          "amount_aed": 4380,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21541
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,380.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/416-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "400A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 400A TP isolator, fire rated",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21543
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "5,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/416-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "500A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 500A TP isolator, fire rated",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6250,
          "amount_aed": 6250,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,250.00",
            "[S]": "TRUE",
            "[T]": "6250"
          }
        },
        {
          "id": "2 - Main/416-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "630A TP isolator, fire rated",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — 630A TP isolator, fire rated",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 7880,
          "amount_aed": 23640,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,880.00",
            "TOWER 1 [O]": "7,880.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,880.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-7880"
          }
        },
        {
          "id": "2 - Main/416-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — SP isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 14000,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21549
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/416-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Isolating switch"
          ],
          "own_description": "TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Isolating switch — TPN isolator",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 12500,
          "amount_aed": 12500,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21551
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/416-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Emergency push button"
          ],
          "own_description": "Emergency stop push button",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Emergency push button — Emergency stop push button",
          "quantity": 141,
          "unit": "Nr.",
          "rate_aed": 220,
          "amount_aed": 31020,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21555
          },
          "extra_columns": {
            "Basement [C]": "7",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "33",
            "Tower 3 [G]": "27",
            "Tower 4 [H]": "28",
            "TOTAL QTY [I]": "141",
            "BASEMENTS [M]": "1,540.00",
            "GF & PODIUM [N]": "3,960.00",
            "TOWER 1 [O]": "6,160.00",
            "TOWER 2 [P]": "7,260.00",
            "TOWER 3 [Q]": "5,940.00",
            "TOWER 4 [R]": "6,160.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/416-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "50mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 50mm x 50mm cable tray",
          "quantity": 475,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 35625,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21561
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "306",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "39",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "38",
            "TOTAL QTY [I]": "475",
            "BASEMENTS [M]": "225.00",
            "GF & PODIUM [N]": "22,950.00",
            "TOWER 1 [O]": "3,375.00",
            "TOWER 2 [P]": "2,925.00",
            "TOWER 3 [Q]": "3,300.00",
            "TOWER 4 [R]": "2,850.00",
            "[S]": "TRUE",
            "[T]": "-525"
          }
        },
        {
          "id": "2 - Main/416-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "100mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 100mm x 50mm cable tray",
          "quantity": 9651,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 772080,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21563
          },
          "extra_columns": {
            "Basement [C]": "1,255",
            "GF & Podium [D]": "1,488",
            "Tower 1 [E]": "1,748",
            "Tower 2 [F]": "1,794",
            "Tower 3 [G]": "1,722",
            "Tower 4 [H]": "1,644",
            "TOTAL QTY [I]": "9,651",
            "BASEMENTS [M]": "100,400.00",
            "GF & PODIUM [N]": "119,040.00",
            "TOWER 1 [O]": "139,840.00",
            "TOWER 2 [P]": "143,520.00",
            "TOWER 3 [Q]": "137,760.00",
            "TOWER 4 [R]": "131,520.00",
            "[S]": "TRUE",
            "[T]": "-8320"
          }
        },
        {
          "id": "2 - Main/416-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "150mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 150mm x 50mm cable tray",
          "quantity": 3205,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 272425,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21565
          },
          "extra_columns": {
            "Basement [C]": "365",
            "GF & Podium [D]": "568",
            "Tower 1 [E]": "710",
            "Tower 2 [F]": "296",
            "Tower 3 [G]": "1,021",
            "Tower 4 [H]": "245",
            "TOTAL QTY [I]": "3,205",
            "BASEMENTS [M]": "31,025.00",
            "GF & PODIUM [N]": "48,280.00",
            "TOWER 1 [O]": "60,350.00",
            "TOWER 2 [P]": "25,160.00",
            "TOWER 3 [Q]": "86,785.00",
            "TOWER 4 [R]": "20,825.00",
            "[S]": "TRUE",
            "[T]": "-39525"
          }
        },
        {
          "id": "2 - Main/416-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "200mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 200mm x 50mm cable tray",
          "quantity": 4762,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 571440,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21567
          },
          "extra_columns": {
            "Basement [C]": "169",
            "GF & Podium [D]": "615",
            "Tower 1 [E]": "552",
            "Tower 2 [F]": "1,221",
            "Tower 3 [G]": "934",
            "Tower 4 [H]": "1,271",
            "TOTAL QTY [I]": "4,762",
            "BASEMENTS [M]": "20,280.00",
            "GF & PODIUM [N]": "73,800.00",
            "TOWER 1 [O]": "66,240.00",
            "TOWER 2 [P]": "146,520.00",
            "TOWER 3 [Q]": "112,080.00",
            "TOWER 4 [R]": "152,520.00",
            "[S]": "TRUE",
            "[T]": "86280"
          }
        },
        {
          "id": "2 - Main/416-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "225mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 225mm x 50mm cable tray",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "2/R/117",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "625.00",
            "TOWER 2 [P]": "625.00",
            "TOWER 3 [Q]": "625.00",
            "TOWER 4 [R]": "625.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/417",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2380515,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/417-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "300mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 300mm x 50mm cable tray",
          "quantity": 3360,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 436800,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21581
          },
          "extra_columns": {
            "Basement [C]": "482",
            "GF & Podium [D]": "353",
            "Tower 1 [E]": "612",
            "Tower 2 [F]": "728",
            "Tower 3 [G]": "428",
            "Tower 4 [H]": "757",
            "TOTAL QTY [I]": "3,360",
            "BASEMENTS [M]": "62,660.00",
            "GF & PODIUM [N]": "45,890.00",
            "TOWER 1 [O]": "79,560.00",
            "TOWER 2 [P]": "94,640.00",
            "TOWER 3 [Q]": "55,640.00",
            "TOWER 4 [R]": "98,410.00",
            "[S]": "TRUE",
            "[T]": "18850"
          }
        },
        {
          "id": "2 - Main/417-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "400mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 400mm x 50mm cable tray",
          "quantity": 176,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 31680,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21583
          },
          "extra_columns": {
            "Basement [C]": "77",
            "GF & Podium [D]": "99",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "176",
            "BASEMENTS [M]": "13,860.00",
            "GF & PODIUM [N]": "17,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "450mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 450mm x 50mm cable tray",
          "quantity": 1250,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 225000,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21585
          },
          "extra_columns": {
            "Basement [C]": "201",
            "GF & Podium [D]": "83",
            "Tower 1 [E]": "202",
            "Tower 2 [F]": "266",
            "Tower 3 [G]": "210",
            "Tower 4 [H]": "288",
            "TOTAL QTY [I]": "1,250",
            "BASEMENTS [M]": "36,180.00",
            "GF & PODIUM [N]": "14,940.00",
            "TOWER 1 [O]": "36,360.00",
            "TOWER 2 [P]": "47,880.00",
            "TOWER 3 [Q]": "37,800.00",
            "TOWER 4 [R]": "51,840.00",
            "[S]": "TRUE",
            "[T]": "15480"
          }
        },
        {
          "id": "2 - Main/417-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "600mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 600mm x 50mm cable tray",
          "quantity": 861,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 215250,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21587
          },
          "extra_columns": {
            "Basement [C]": "378",
            "GF & Podium [D]": "480",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "861",
            "BASEMENTS [M]": "94,500.00",
            "GF & PODIUM [N]": "120,000.00",
            "TOWER 1 [O]": "250.00",
            "TOWER 2 [P]": "250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "250.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "750mm x 100mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 750mm x 100mm cable tray",
          "quantity": 170,
          "unit": "m",
          "rate_aed": 315,
          "amount_aed": 53550,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21589
          },
          "extra_columns": {
            "Basement [C]": "170",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "170",
            "BASEMENTS [M]": "53,550.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "900mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray — 900mm wide cable tray",
          "quantity": 9,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 3375,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "100mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 100mm x 50mm cable tray",
          "quantity": 243,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 19440,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "45",
            "Tower 2 [F]": "48",
            "Tower 3 [G]": "106",
            "Tower 4 [H]": "44",
            "TOTAL QTY [I]": "243",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "3,840.00",
            "TOWER 3 [Q]": "8,480.00",
            "TOWER 4 [R]": "3,520.00",
            "[S]": "TRUE",
            "[T]": "-80"
          }
        },
        {
          "id": "2 - Main/417-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "150mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 150mm x 50mm cable tray",
          "quantity": 206,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 17510,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21597
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "17",
            "Tower 2 [F]": "47",
            "Tower 3 [G]": "95",
            "Tower 4 [H]": "47",
            "TOTAL QTY [I]": "206",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,445.00",
            "TOWER 2 [P]": "3,995.00",
            "TOWER 3 [Q]": "8,075.00",
            "TOWER 4 [R]": "3,995.00",
            "[S]": "TRUE",
            "[T]": "2550"
          }
        },
        {
          "id": "2 - Main/417-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "200mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 200mm x 50mm cable tray",
          "quantity": 192,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 23040,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "59",
            "Tower 2 [F]": "63",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "65",
            "TOTAL QTY [I]": "192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,080.00",
            "TOWER 2 [P]": "7,560.00",
            "TOWER 3 [Q]": "600.00",
            "TOWER 4 [R]": "7,800.00",
            "[S]": "TRUE",
            "[T]": "720"
          }
        },
        {
          "id": "2 - Main/417-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "225mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 225mm x 50mm cable tray",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 8880,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "30",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,560.00",
            "TOWER 2 [P]": "1,920.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "1,800.00",
            "[S]": "TRUE",
            "[T]": "240"
          }
        },
        {
          "id": "2 - Main/417-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "300mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 300mm x 50mm cable tray",
          "quantity": 63,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 8190,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21603
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "27",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "63",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,560.00",
            "TOWER 2 [P]": "1,560.00",
            "TOWER 3 [Q]": "3,510.00",
            "TOWER 4 [R]": "1,560.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "400mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 400mm x 50mm cable tray",
          "quantity": 68,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 12240,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "20",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "19",
            "TOTAL QTY [I]": "68",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "3,960.00",
            "TOWER 3 [Q]": "1,260.00",
            "TOWER 4 [R]": "3,420.00",
            "[S]": "TRUE",
            "[T]": "-180"
          }
        },
        {
          "id": "2 - Main/417-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable tray with sun shade cover"
          ],
          "own_description": "600mm x 50mm cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable tray with sun shade cover — 600mm x 50mm cable tray",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 6250,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21607
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "500.00",
            "TOWER 2 [P]": "250.00",
            "TOWER 3 [Q]": "3,250.00",
            "TOWER 4 [R]": "2,250.00",
            "[S]": "TRUE",
            "[T]": "1750"
          }
        },
        {
          "id": "2 - Main/417-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "100mm x 50mm dual compartment GI trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable trunking — 100mm x 50mm dual compartment GI trunking",
          "quantity": 5091,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 560010,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21611
          },
          "extra_columns": {
            "Basement [C]": "4,078",
            "GF & Podium [D]": "1,013",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5,091",
            "BASEMENTS [M]": "448,580.00",
            "GF & PODIUM [N]": "111,430.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "50mm x 50mm cable trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable trunking — 50mm x 50mm cable trunking",
          "quantity": 2756,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 220480,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,756",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2,756",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "220,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "100mm x 50mm cable trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable trunking — 100mm x 50mm cable trunking",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 3960,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "36",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,960.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/417-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "100mm x 100mm cable trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — Cable trunking — 100mm x 100mm cable trunking",
          "quantity": 3960,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 435600,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21617
          },
          "extra_columns": {
            "Basement [C]": "72",
            "GF & Podium [D]": "222",
            "Tower 1 [E]": "874",
            "Tower 2 [F]": "909",
            "Tower 3 [G]": "947",
            "Tower 4 [H]": "936",
            "TOTAL QTY [I]": "3,960",
            "BASEMENTS [M]": "7,920.00",
            "GF & PODIUM [N]": "24,420.00",
            "TOWER 1 [O]": "96,140.00",
            "TOWER 2 [P]": "99,990.00",
            "TOWER 3 [Q]": "104,170.00",
            "TOWER 4 [R]": "102,960.00",
            "[S]": "TRUE",
            "[T]": "6820"
          }
        },
        {
          "id": "2 - Main/417-T",
          "item_code": "T",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "PVC pipe"
          ],
          "own_description": "50mm diameter PVC pipe",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — PVC pipe — 50mm diameter PVC pipe",
          "quantity": 3463,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 69260,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21621
          },
          "extra_columns": {
            "Basement [C]": "268",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "700",
            "Tower 2 [F]": "832",
            "Tower 3 [G]": "851",
            "Tower 4 [H]": "812",
            "TOTAL QTY [I]": "3,463",
            "BASEMENTS [M]": "5,360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "14,000.00",
            "TOWER 2 [P]": "16,640.00",
            "TOWER 3 [Q]": "17,020.00",
            "TOWER 4 [R]": "16,240.00",
            "[S]": "TRUE",
            "[T]": "2240"
          }
        },
        {
          "id": "2 - Main/417-U",
          "item_code": "U",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary",
            "PVC pipe"
          ],
          "own_description": "Cable containment to Retail DB",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Containment; including fixings, supports, hangers, fittings, accessories and all ancillary works as necessary — PVC pipe — Cable containment to Retail DB",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 30000,
          "amount_aed": 30000,
          "amount_state": "number",
          "printed_page": "2/R/118",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21623
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/418",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 5969723,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/418-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "1C x 70mm² G/Y earthing cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — 1C x 70mm² G/Y earthing cable",
          "quantity": 545,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 32700,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21640
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "545",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "545",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/418-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "1C x 150mm² G/Y earthing cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — 1C x 150mm² G/Y earthing cable",
          "quantity": 594,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 65340,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21642
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "594",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "594",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/418-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "1C x 240mm² PVC insulated earthing cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — 1C x 240mm² PVC insulated earthing cable",
          "quantity": 178,
          "unit": "m",
          "rate_aed": 176,
          "amount_aed": 31328,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21644
          },
          "extra_columns": {
            "Basement [C]": "178",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "178",
            "BASEMENTS [M]": "31,328.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/418-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "25 x 3mm copper tape",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — 25 x 3mm copper tape",
          "quantity": 3238,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 388560,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21646
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "475",
            "Tower 1 [E]": "593",
            "Tower 2 [F]": "755",
            "Tower 3 [G]": "662",
            "Tower 4 [H]": "753",
            "TOTAL QTY [I]": "3,238",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "57,000.00",
            "TOWER 1 [O]": "71,160.00",
            "TOWER 2 [P]": "90,600.00",
            "TOWER 3 [Q]": "79,440.00",
            "TOWER 4 [R]": "90,360.00",
            "[S]": "TRUE",
            "[T]": "19200"
          }
        },
        {
          "id": "2 - Main/418-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Down conductor",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — Down conductor",
          "quantity": 244,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 63440,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21648
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "56",
            "Tower 3 [G]": "57",
            "Tower 4 [H]": "56",
            "TOTAL QTY [I]": "244",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,020.00",
            "TOWER 1 [O]": "12,480.00",
            "TOWER 2 [P]": "14,560.00",
            "TOWER 3 [Q]": "14,820.00",
            "TOWER 4 [R]": "14,560.00",
            "[S]": "TRUE",
            "[T]": "2080"
          }
        },
        {
          "id": "2 - Main/418-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Down conductor connected to pile cap",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — Down conductor connected to pile cap",
          "quantity": 107,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 27820,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21650
          },
          "extra_columns": {
            "Basement [C]": "107",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "107",
            "BASEMENTS [M]": "27,820.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/418-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Earth bar",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — Earth bar",
          "quantity": 449,
          "unit": "Nr.",
          "rate_aed": 980,
          "amount_aed": 440020,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21652
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "33",
            "Tower 1 [E]": "96",
            "Tower 2 [F]": "112",
            "Tower 3 [G]": "104",
            "Tower 4 [H]": "104",
            "TOTAL QTY [I]": "449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,340.00",
            "TOWER 1 [O]": "94,080.00",
            "TOWER 2 [P]": "109,760.00",
            "TOWER 3 [Q]": "101,920.00",
            "TOWER 4 [R]": "101,920.00",
            "[S]": "TRUE",
            "[T]": "7840"
          }
        },
        {
          "id": "2 - Main/418-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Earth pit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — Earth pit",
          "quantity": 113,
          "unit": "Nr.",
          "rate_aed": 1580,
          "amount_aed": 178540,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21654
          },
          "extra_columns": {
            "Basement [C]": "113",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "178,540.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/418-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Earthing and Lightning Protection System Installation",
            "Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Strike pad",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Earthing and Lightning Protection System Installation — Earthing and lightning protection system; including earthworks, fixings, bondings, accessories and all ancillary works as necessary — Strike pad",
          "quantity": 79,
          "unit": "Nr.",
          "rate_aed": 85,
          "amount_aed": 6715,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21656
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "16",
            "Tower 4 [H]": "22",
            "TOTAL QTY [I]": "79",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,615.00",
            "TOWER 2 [P]": "1,870.00",
            "TOWER 3 [Q]": "1,360.00",
            "TOWER 4 [R]": "1,870.00",
            "[S]": "TRUE",
            "[T]": "255"
          }
        },
        {
          "id": "2 - Main/418-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched single socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched single socket outlet points",
          "quantity": 12557,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 3390390,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21662
          },
          "extra_columns": {
            "Basement [C]": "72",
            "GF & Podium [D]": "713",
            "Tower 1 [E]": "2,711",
            "Tower 2 [F]": "3,212",
            "Tower 3 [G]": "2,935",
            "Tower 4 [H]": "2,914",
            "TOTAL QTY [I]": "12,557",
            "BASEMENTS [M]": "19,440.00",
            "GF & PODIUM [N]": "192,510.00",
            "TOWER 1 [O]": "731,970.00",
            "TOWER 2 [P]": "867,240.00",
            "TOWER 3 [Q]": "792,450.00",
            "TOWER 4 [R]": "786,780.00",
            "[S]": "TRUE",
            "[T]": "54810"
          }
        },
        {
          "id": "2 - Main/418-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched single socket outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched single socket outlet: W/P points",
          "quantity": 208,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 56160,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21664
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "61",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "208",
            "BASEMENTS [M]": "24,840.00",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "1,890.00",
            "TOWER 2 [P]": "16,470.00",
            "TOWER 3 [Q]": "1,890.00",
            "TOWER 4 [R]": "8,370.00",
            "[S]": "TRUE",
            "[T]": "6480"
          }
        },
        {
          "id": "2 - Main/418-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched single socket with dual USB ports outlet (Type-C & A) points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched single socket with dual USB ports outlet (Type-C & A) points",
          "quantity": 4773,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1288710,
          "amount_state": "number",
          "printed_page": "2/R/119",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21666
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "156",
            "Tower 1 [E]": "1,087",
            "Tower 2 [F]": "1,213",
            "Tower 3 [G]": "1,173",
            "Tower 4 [H]": "1,144",
            "TOTAL QTY [I]": "4,773",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,120.00",
            "TOWER 1 [O]": "293,490.00",
            "TOWER 2 [P]": "327,510.00",
            "TOWER 3 [Q]": "316,710.00",
            "TOWER 4 [R]": "308,880.00",
            "[S]": "TRUE",
            "[T]": "15390"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/419",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 8870850,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/419-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched fused connection unit (spur) outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched fused connection unit (spur) outlet points",
          "quantity": 1528,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 412560,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21680
          },
          "extra_columns": {
            "Basement [C]": "39",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "314",
            "Tower 2 [F]": "322",
            "Tower 3 [G]": "339",
            "Tower 4 [H]": "322",
            "TOTAL QTY [I]": "1,528",
            "BASEMENTS [M]": "10,530.00",
            "GF & PODIUM [N]": "51,840.00",
            "TOWER 1 [O]": "84,780.00",
            "TOWER 2 [P]": "86,940.00",
            "TOWER 3 [Q]": "91,530.00",
            "TOWER 4 [R]": "86,940.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/419-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched fused connection unit (spur) outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched fused connection unit (spur) outlet: W/P points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 270,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21682
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "270.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched fused connection unit with front flex outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched fused connection unit with front flex outlet points",
          "quantity": 716,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 193320,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21684
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "161",
            "Tower 2 [F]": "183",
            "Tower 3 [G]": "153",
            "Tower 4 [H]": "219",
            "TOTAL QTY [I]": "716",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "43,470.00",
            "TOWER 2 [P]": "49,410.00",
            "TOWER 3 [Q]": "41,310.00",
            "TOWER 4 [R]": "59,130.00",
            "[S]": "TRUE",
            "[T]": "15660"
          }
        },
        {
          "id": "2 - Main/419-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched fused connection unit with front flex outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched fused connection unit with front flex outlet: W/P points",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 810,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21686
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "270.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "270.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A switched twin socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A switched twin socket outlet points",
          "quantity": 8555,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2309850,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21688
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "326",
            "Tower 1 [E]": "1,974",
            "Tower 2 [F]": "2,089",
            "Tower 3 [G]": "2,124",
            "Tower 4 [H]": "2,042",
            "TOTAL QTY [I]": "8,555",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "88,020.00",
            "TOWER 1 [O]": "532,980.00",
            "TOWER 2 [P]": "564,030.00",
            "TOWER 3 [Q]": "573,480.00",
            "TOWER 4 [R]": "551,340.00",
            "[S]": "TRUE",
            "[T]": "18360"
          }
        },
        {
          "id": "2 - Main/419-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A unswitched fused connection unit (Spur) outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A unswitched fused connection unit (Spur) outlet points",
          "quantity": 1770,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 477900,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21690
          },
          "extra_columns": {
            "Basement [C]": "22",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "425",
            "Tower 2 [F]": "440",
            "Tower 3 [G]": "399",
            "Tower 4 [H]": "447",
            "TOTAL QTY [I]": "1,770",
            "BASEMENTS [M]": "5,940.00",
            "GF & PODIUM [N]": "9,990.00",
            "TOWER 1 [O]": "114,750.00",
            "TOWER 2 [P]": "118,800.00",
            "TOWER 3 [Q]": "107,730.00",
            "TOWER 4 [R]": "120,690.00",
            "[S]": "TRUE",
            "[T]": "5940"
          }
        },
        {
          "id": "2 - Main/419-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A unswitched fused connection unit (spur) outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A unswitched fused connection unit (spur) outlet: W/P points",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 3240,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21692
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "270.00",
            "TOWER 4 [R]": "270.00",
            "[S]": "TRUE",
            "[T]": "270"
          }
        },
        {
          "id": "2 - Main/419-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A unswitched spur outlet with neon indicator outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A unswitched spur outlet with neon indicator outlet points",
          "quantity": 2119,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 572130,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21694
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "88",
            "Tower 1 [E]": "496",
            "Tower 2 [F]": "502",
            "Tower 3 [G]": "533",
            "Tower 4 [H]": "500",
            "TOTAL QTY [I]": "2,119",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,760.00",
            "TOWER 1 [O]": "133,920.00",
            "TOWER 2 [P]": "135,540.00",
            "TOWER 3 [Q]": "143,910.00",
            "TOWER 4 [R]": "135,000.00",
            "[S]": "TRUE",
            "[T]": "1080"
          }
        },
        {
          "id": "2 - Main/419-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 13A UPS switched socket outlet twin points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 13A UPS switched socket outlet twin points",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 7830,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21696
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,830.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 15A switched single socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 15A switched single socket outlet points",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2160,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21698
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "2,160.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 15A switched single socket outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 15A switched single socket outlet: W/P points",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1350,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21700
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "1,350.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 16A Industrial type switched socket outlet (SP+N+E) points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 16A Industrial type switched socket outlet (SP+N+E) points",
          "quantity": 294,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 79380,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "52",
            "Tower 2 [F]": "72",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "294",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,320.00",
            "TOWER 1 [O]": "14,040.00",
            "TOWER 2 [P]": "19,440.00",
            "TOWER 3 [Q]": "27,540.00",
            "TOWER 4 [R]": "14,040.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/419-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A DP switch points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A DP switch points",
          "quantity": 11495,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 3103650,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21704
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "406",
            "Tower 1 [E]": "2,662",
            "Tower 2 [F]": "2,818",
            "Tower 3 [G]": "2,868",
            "Tower 4 [H]": "2,741",
            "TOTAL QTY [I]": "11,495",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "109,620.00",
            "TOWER 1 [O]": "718,740.00",
            "TOWER 2 [P]": "760,860.00",
            "TOWER 3 [Q]": "774,360.00",
            "TOWER 4 [R]": "740,070.00",
            "[S]": "TRUE",
            "[T]": "21330"
          }
        },
        {
          "id": "2 - Main/419-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A flex outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A flex outlet points",
          "quantity": 2811,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 758970,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21706
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "108",
            "Tower 1 [E]": "636",
            "Tower 2 [F]": "707",
            "Tower 3 [G]": "685",
            "Tower 4 [H]": "675",
            "TOTAL QTY [I]": "2,811",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,160.00",
            "TOWER 1 [O]": "171,720.00",
            "TOWER 2 [P]": "190,890.00",
            "TOWER 3 [Q]": "184,950.00",
            "TOWER 4 [R]": "182,250.00",
            "[S]": "TRUE",
            "[T]": "10530"
          }
        },
        {
          "id": "2 - Main/419-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A flex outlet: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A flex outlet: W/P points",
          "quantity": 3509,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 947430,
          "amount_state": "number",
          "printed_page": "2/R/120",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21708
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "122",
            "Tower 1 [E]": "812",
            "Tower 2 [F]": "864",
            "Tower 3 [G]": "873",
            "Tower 4 [H]": "838",
            "TOTAL QTY [I]": "3,509",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,940.00",
            "TOWER 1 [O]": "219,240.00",
            "TOWER 2 [P]": "233,280.00",
            "TOWER 3 [Q]": "235,710.00",
            "TOWER 4 [R]": "226,260.00",
            "[S]": "TRUE",
            "[T]": "7020"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/420",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2093910,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/420-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A switched spur outlet with neon indicator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A switched spur outlet with neon indicator points",
          "quantity": 2451,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 661770,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21722
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "70",
            "Tower 1 [E]": "553",
            "Tower 2 [F]": "694",
            "Tower 3 [G]": "546",
            "Tower 4 [H]": "588",
            "TOTAL QTY [I]": "2,451",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "149,310.00",
            "TOWER 2 [P]": "187,380.00",
            "TOWER 3 [Q]": "147,420.00",
            "TOWER 4 [R]": "158,760.00",
            "[S]": "TRUE",
            "[T]": "9450"
          }
        },
        {
          "id": "2 - Main/420-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A switched spur outlet with neon indicator - high level points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A switched spur outlet with neon indicator - high level points",
          "quantity": 1637,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 441990,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21724
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "358",
            "Tower 2 [F]": "390",
            "Tower 3 [G]": "435",
            "Tower 4 [H]": "402",
            "TOTAL QTY [I]": "1,637",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,040.00",
            "TOWER 1 [O]": "96,660.00",
            "TOWER 2 [P]": "105,300.00",
            "TOWER 3 [Q]": "117,450.00",
            "TOWER 4 [R]": "108,540.00",
            "[S]": "TRUE",
            "[T]": "11880"
          }
        },
        {
          "id": "2 - Main/420-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 40A TP commando socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 40A TP commando socket outlet points",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 1750,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21726
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 63A TP commando socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 63A TP commando socket outlet points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 350,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21728
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Connection unit points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Connection unit points",
          "quantity": 3454,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 932580,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21730
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "122",
            "Tower 1 [E]": "810",
            "Tower 2 [F]": "828",
            "Tower 3 [G]": "872",
            "Tower 4 [H]": "822",
            "TOTAL QTY [I]": "3,454",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,940.00",
            "TOWER 1 [O]": "218,700.00",
            "TOWER 2 [P]": "223,560.00",
            "TOWER 3 [Q]": "235,440.00",
            "TOWER 4 [R]": "221,940.00",
            "[S]": "TRUE",
            "[T]": "3240"
          }
        },
        {
          "id": "2 - Main/420-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 20A SP isolator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 20A SP isolator points",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 4200,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21732
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 32A TPN isolator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 32A TPN isolator points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21734
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Isolator for signage: W/P points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Isolator for signage: W/P points",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 2800,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21736
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "700.00",
            "TOWER 2 [P]": "700.00",
            "TOWER 3 [Q]": "700.00",
            "TOWER 4 [R]": "700.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to SPN isolator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to SPN isolator points",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 4200,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21738
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to TP isolator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to TP isolator points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21740
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "700.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to TPN isolator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to TPN isolator points",
          "quantity": 87,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 30450,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21742
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "87",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "30,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Type FB-A; floor box with 1no. 5A single switched socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Type FB-A; floor box with 1no. 5A single switched socket outlet points",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 4860,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21744
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Type FB-C; floor box with 1no. 13A single switched socket outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Type FB-C; floor box with 1no. 13A single switched socket outlet points",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21746
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Type FB-F; floor box with 1no. UPS 13A twin switched socket outlet, 1no. normal 13A twin switched socket outlet & 2nos. twin data outlet points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Type FB-F; floor box with 1no. UPS 13A twin switched socket outlet, 1no. normal 13A twin switched socket outlet & 2nos. twin data outlet points",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1620,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21748
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/420-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Small Power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to Type FB; floor box at 6BR penthouse points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Small Power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to Type FB; floor box at 6BR penthouse points",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 3240,
          "amount_state": "number",
          "printed_page": "2/R/121",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21750
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,620.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,620.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-1620"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/421",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3014405,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/421-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched single socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched single socket outlet",
          "quantity": 12557,
          "unit": "Nr.",
          "rate_aed": 25,
          "amount_aed": 313925,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21767
          },
          "extra_columns": {
            "Basement [C]": "72",
            "GF & Podium [D]": "713",
            "Tower 1 [E]": "2,711",
            "Tower 2 [F]": "3,212",
            "Tower 3 [G]": "2,935",
            "Tower 4 [H]": "2,914",
            "TOTAL QTY [I]": "12,557",
            "BASEMENTS [M]": "1,800.00",
            "GF & PODIUM [N]": "17,825.00",
            "TOWER 1 [O]": "67,775.00",
            "TOWER 2 [P]": "80,300.00",
            "TOWER 3 [Q]": "73,375.00",
            "TOWER 4 [R]": "72,850.00",
            "[S]": "TRUE",
            "[T]": "5075"
          }
        },
        {
          "id": "2 - Main/421-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched single socket outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched single socket outlet: W/P",
          "quantity": 208,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 18720,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21769
          },
          "extra_columns": {
            "Basement [C]": "92",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "61",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "208",
            "BASEMENTS [M]": "8,280.00",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "630.00",
            "TOWER 2 [P]": "5,490.00",
            "TOWER 3 [Q]": "630.00",
            "TOWER 4 [R]": "2,790.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/421-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched single socket with dual USB ports outlet (Type-C & A)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched single socket with dual USB ports outlet (Type-C & A)",
          "quantity": 4773,
          "unit": "Nr.",
          "rate_aed": 140,
          "amount_aed": 668220,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21771
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "156",
            "Tower 1 [E]": "1,087",
            "Tower 2 [F]": "1,213",
            "Tower 3 [G]": "1,173",
            "Tower 4 [H]": "1,144",
            "TOTAL QTY [I]": "4,773",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,840.00",
            "TOWER 1 [O]": "152,180.00",
            "TOWER 2 [P]": "169,820.00",
            "TOWER 3 [Q]": "164,220.00",
            "TOWER 4 [R]": "160,160.00",
            "[S]": "TRUE",
            "[T]": "7980"
          }
        },
        {
          "id": "2 - Main/421-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched fused connection unit (spur) outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched fused connection unit (spur) outlet",
          "quantity": 1528,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 53480,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21773
          },
          "extra_columns": {
            "Basement [C]": "39",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "314",
            "Tower 2 [F]": "322",
            "Tower 3 [G]": "339",
            "Tower 4 [H]": "322",
            "TOTAL QTY [I]": "1,528",
            "BASEMENTS [M]": "1,365.00",
            "GF & PODIUM [N]": "6,720.00",
            "TOWER 1 [O]": "10,990.00",
            "TOWER 2 [P]": "11,270.00",
            "TOWER 3 [Q]": "11,865.00",
            "TOWER 4 [R]": "11,270.00",
            "[S]": "TRUE",
            "[T]": "280"
          }
        },
        {
          "id": "2 - Main/421-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched fused connection unit (spur) outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched fused connection unit (spur) outlet: W/P",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 65,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21775
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "65.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched fused connection unit with front flex outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched fused connection unit with front flex outlet",
          "quantity": 722,
          "unit": "Nr.",
          "rate_aed": 40,
          "amount_aed": 28880,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21777
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "161",
            "Tower 2 [F]": "183",
            "Tower 3 [G]": "159",
            "Tower 4 [H]": "219",
            "TOTAL QTY [I]": "722",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,440.00",
            "TOWER 2 [P]": "7,320.00",
            "TOWER 3 [Q]": "6,360.00",
            "TOWER 4 [R]": "8,760.00",
            "[S]": "TRUE",
            "[T]": "2320"
          }
        },
        {
          "id": "2 - Main/421-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched fused connection unit with front flex outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched fused connection unit with front flex outlet: W/P",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 70,
          "amount_aed": 210,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21779
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "70.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "70.00",
            "TOWER 4 [R]": "70.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A switched twin socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A switched twin socket outlet",
          "quantity": 8567,
          "unit": "Nr.",
          "rate_aed": 35,
          "amount_aed": 299845,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21781
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "326",
            "Tower 1 [E]": "1,974",
            "Tower 2 [F]": "2,089",
            "Tower 3 [G]": "2,136",
            "Tower 4 [H]": "2,042",
            "TOTAL QTY [I]": "8,567",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,410.00",
            "TOWER 1 [O]": "69,090.00",
            "TOWER 2 [P]": "73,115.00",
            "TOWER 3 [Q]": "74,760.00",
            "TOWER 4 [R]": "71,470.00",
            "[S]": "TRUE",
            "[T]": "2380"
          }
        },
        {
          "id": "2 - Main/421-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A unswitched fused connection unit (Spur) outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A unswitched fused connection unit (Spur) outlet",
          "quantity": 1770,
          "unit": "Nr.",
          "rate_aed": 40,
          "amount_aed": 70800,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21783
          },
          "extra_columns": {
            "Basement [C]": "22",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "425",
            "Tower 2 [F]": "440",
            "Tower 3 [G]": "399",
            "Tower 4 [H]": "447",
            "TOTAL QTY [I]": "1,770",
            "BASEMENTS [M]": "880.00",
            "GF & PODIUM [N]": "1,480.00",
            "TOWER 1 [O]": "17,000.00",
            "TOWER 2 [P]": "17,600.00",
            "TOWER 3 [Q]": "15,960.00",
            "TOWER 4 [R]": "17,880.00",
            "[S]": "TRUE",
            "[T]": "880"
          }
        },
        {
          "id": "2 - Main/421-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A unswitched fused connection unit (spur) outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A unswitched fused connection unit (spur) outlet: W/P",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 70,
          "amount_aed": 840,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21785
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "70.00",
            "TOWER 4 [R]": "70.00",
            "[S]": "TRUE",
            "[T]": "70"
          }
        },
        {
          "id": "2 - Main/421-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A unswitched spur outlet with neon indicator outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A unswitched spur outlet with neon indicator outlet",
          "quantity": 2119,
          "unit": "Nr.",
          "rate_aed": 40,
          "amount_aed": 84760,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21787
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "88",
            "Tower 1 [E]": "496",
            "Tower 2 [F]": "502",
            "Tower 3 [G]": "533",
            "Tower 4 [H]": "500",
            "TOTAL QTY [I]": "2,119",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,520.00",
            "TOWER 1 [O]": "19,840.00",
            "TOWER 2 [P]": "20,080.00",
            "TOWER 3 [Q]": "21,320.00",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE",
            "[T]": "160"
          }
        },
        {
          "id": "2 - Main/421-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "13A UPS switched socket outlet twin",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 13A UPS switched socket outlet twin",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 45,
          "amount_aed": 1305,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21789
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,305.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "15A switched single socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 15A switched single socket outlet",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 45,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21791
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "360.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "15A switched single socket outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 15A switched single socket outlet: W/P",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 75,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21793
          },
          "extra_columns": {
            "Basement [C]": "5",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "375.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "16A Industrial type switched socket outlet (SP+N+E)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 16A Industrial type switched socket outlet (SP+N+E)",
          "quantity": 294,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 67620,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21795
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "52",
            "Tower 2 [F]": "72",
            "Tower 3 [G]": "102",
            "Tower 4 [H]": "52",
            "TOTAL QTY [I]": "294",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,680.00",
            "TOWER 1 [O]": "11,960.00",
            "TOWER 2 [P]": "16,560.00",
            "TOWER 3 [Q]": "23,460.00",
            "TOWER 4 [R]": "11,960.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/421-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A DP switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A DP switch",
          "quantity": 11495,
          "unit": "Nr.",
          "rate_aed": 110,
          "amount_aed": 1264450,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21797
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "406",
            "Tower 1 [E]": "2,662",
            "Tower 2 [F]": "2,818",
            "Tower 3 [G]": "2,868",
            "Tower 4 [H]": "2,741",
            "TOTAL QTY [I]": "11,495",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "44,660.00",
            "TOWER 1 [O]": "292,820.00",
            "TOWER 2 [P]": "309,980.00",
            "TOWER 3 [Q]": "315,480.00",
            "TOWER 4 [R]": "301,510.00",
            "[S]": "TRUE",
            "[T]": "8690"
          }
        },
        {
          "id": "2 - Main/421-S",
          "item_code": "S",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A flex outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A flex outlet",
          "quantity": 2811,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 140550,
          "amount_state": "number",
          "printed_page": "2/R/122",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21799
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "108",
            "Tower 1 [E]": "636",
            "Tower 2 [F]": "707",
            "Tower 3 [G]": "685",
            "Tower 4 [H]": "675",
            "TOTAL QTY [I]": "2,811",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,400.00",
            "TOWER 1 [O]": "31,800.00",
            "TOWER 2 [P]": "35,350.00",
            "TOWER 3 [Q]": "34,250.00",
            "TOWER 4 [R]": "33,750.00",
            "[S]": "TRUE",
            "[T]": "1950"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/422",
      "section": "POWER INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 826380,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/422-A",
          "item_code": "A",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A flex outlet: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A flex outlet: W/P",
          "quantity": 3509,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 280720,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21816
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "122",
            "Tower 1 [E]": "812",
            "Tower 2 [F]": "864",
            "Tower 3 [G]": "873",
            "Tower 4 [H]": "838",
            "TOTAL QTY [I]": "3,509",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,760.00",
            "TOWER 1 [O]": "64,960.00",
            "TOWER 2 [P]": "69,120.00",
            "TOWER 3 [Q]": "69,840.00",
            "TOWER 4 [R]": "67,040.00",
            "[S]": "TRUE",
            "[T]": "2080"
          }
        },
        {
          "id": "2 - Main/422-B",
          "item_code": "B",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A switched spur outlet with neon indicator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A switched spur outlet with neon indicator",
          "quantity": 2451,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 147060,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21818
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "70",
            "Tower 1 [E]": "553",
            "Tower 2 [F]": "694",
            "Tower 3 [G]": "546",
            "Tower 4 [H]": "588",
            "TOTAL QTY [I]": "2,451",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,200.00",
            "TOWER 1 [O]": "33,180.00",
            "TOWER 2 [P]": "41,640.00",
            "TOWER 3 [Q]": "32,760.00",
            "TOWER 4 [R]": "35,280.00",
            "[S]": "TRUE",
            "[T]": "2100"
          }
        },
        {
          "id": "2 - Main/422-C",
          "item_code": "C",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A switched spur outlet with neon indicator - high level",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A switched spur outlet with neon indicator - high level",
          "quantity": 1637,
          "unit": "Nr.",
          "rate_aed": 90,
          "amount_aed": 147330,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21820
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "52",
            "Tower 1 [E]": "358",
            "Tower 2 [F]": "390",
            "Tower 3 [G]": "435",
            "Tower 4 [H]": "402",
            "TOTAL QTY [I]": "1,637",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,680.00",
            "TOWER 1 [O]": "32,220.00",
            "TOWER 2 [P]": "35,100.00",
            "TOWER 3 [Q]": "39,150.00",
            "TOWER 4 [R]": "36,180.00",
            "[S]": "TRUE",
            "[T]": "3960"
          }
        },
        {
          "id": "2 - Main/422-D",
          "item_code": "D",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "40A TP commando socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 40A TP commando socket outlet",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 270,
          "amount_aed": 1350,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21822
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-E",
          "item_code": "E",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "63A TP commando socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 63A TP commando socket outlet",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 290,
          "amount_aed": 290,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21824
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "290.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-F",
          "item_code": "F",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Connection unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Connection unit",
          "quantity": 3454,
          "unit": "Nr.",
          "rate_aed": 50,
          "amount_aed": 172700,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21826
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "122",
            "Tower 1 [E]": "810",
            "Tower 2 [F]": "828",
            "Tower 3 [G]": "872",
            "Tower 4 [H]": "822",
            "TOTAL QTY [I]": "3,454",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,100.00",
            "TOWER 1 [O]": "40,500.00",
            "TOWER 2 [P]": "41,400.00",
            "TOWER 3 [Q]": "43,600.00",
            "TOWER 4 [R]": "41,100.00",
            "[S]": "TRUE",
            "[T]": "600"
          }
        },
        {
          "id": "2 - Main/422-G",
          "item_code": "G",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "20A SP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 20A SP isolator",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 1920,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21828
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-H",
          "item_code": "H",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "32A TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — 32A TPN isolator",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21830
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-J",
          "item_code": "J",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Isolator for signage: W/P",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Isolator for signage: W/P",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 2560,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21832
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "640.00",
            "TOWER 2 [P]": "640.00",
            "TOWER 3 [Q]": "640.00",
            "TOWER 4 [R]": "640.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-K",
          "item_code": "K",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "SPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — SPN isolator",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 3840,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21834
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-L",
          "item_code": "L",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "TP isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — TP isolator",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 660,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21836
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "660.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-M",
          "item_code": "M",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "TPN isolator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — TPN isolator",
          "quantity": 87,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 28710,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21838
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "87",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "87",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,710.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-N",
          "item_code": "N",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Type FB-A; floor box with 1no. 5A single switched socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Type FB-A; floor box with 1no. 5A single switched socket outlet",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 830,
          "amount_aed": 14940,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21840
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-P",
          "item_code": "P",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Type FB-C; floor box with 1no. 13A single switched socket outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Type FB-C; floor box with 1no. 13A single switched socket outlet",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 830,
          "amount_aed": 8300,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21842
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-Q",
          "item_code": "Q",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Type FB-F; floor box with 1no. UPS 13A twin switched socket outlet, 1no. normal 13A twin switched socket outlet & 2nos. twin data outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Type FB-F; floor box with 1no. UPS 13A twin switched socket outlet, 1no. normal 13A twin switched socket outlet & 2nos. twin data outlet",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 950,
          "amount_aed": 5700,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21844
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/422-R",
          "item_code": "R",
          "section": "POWER INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers, and all ancillary works as necessary"
          ],
          "own_description": "Type FB; floor box at 6BR penthouse",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — POWER INSTALLATION — Accessories; including fixings, supports, hangers, and all ancillary works as necessary — Type FB; floor box at 6BR penthouse",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 830,
          "amount_aed": 9960,
          "amount_state": "number",
          "printed_page": "2/R/123",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21846
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,980.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,980.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-4980"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/423",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 38339470,
      "section_notes": [
        "Note: Refer to the following",
        "1. Electrical Drawing Nr. ZD-3250587-CKR-DWG-PDM-ELE-1000 to 1134, 1980 to 1996, ZD-3250587-CKR-DWG-1B2-ELE-9125 to 9427, TW1-ELE-1040 to 1540, TW2-ELE-1040 to 1620,  TW3-ELE-1040 to 1570, and TW4-ELE-1040 to 1570; all inclusive",
        "2. Specialist Lighting Drawing Nr. ZD-3250587-MLD-DWG-ZZZ-SLU-1010 to 1089, ZD-3250587-MLD-DWG-PDM-SLU-1014 to 4005, ZD-3250587-MLD-DWG-TWR-SLU-1052 to 4003; all inclusive",
        "3. Lighting Schedule; ZD-3250587-MLD-SCH-ZZZ-SLU-0001",
        "4. Lighting Specifications; ZD-3250587-MLD-SPC-ZZZ-SLU-0001",
        "5. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/423-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to lighting points",
          "quantity": 48354,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 12088500,
          "amount_state": "number",
          "printed_page": "2/R/124",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21874
          },
          "extra_columns": {
            "Basement [C]": "1,617",
            "GF & Podium [D]": "3,929",
            "Tower 1 [E]": "9,578",
            "Tower 2 [F]": "11,234",
            "Tower 3 [G]": "11,573",
            "Tower 4 [H]": "10,423",
            "TOTAL QTY [I]": "48,354",
            "BASEMENTS [M]": "404,250.00",
            "GF & PODIUM [N]": "982,250.00",
            "TOWER 1 [O]": "2,394,500.00",
            "TOWER 2 [P]": "2,808,500.00",
            "TOWER 3 [Q]": "2,893,250.00",
            "TOWER 4 [R]": "2,605,750.00",
            "[S]": "TRUE",
            "[T]": "211250"
          }
        },
        {
          "id": "2 - Main/423-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to linear lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to linear lighting points",
          "quantity": 120973,
          "unit": "m",
          "rate_aed": 140,
          "amount_aed": 16936220,
          "amount_state": "number",
          "printed_page": "2/R/124",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21876
          },
          "extra_columns": {
            "Basement [C]": "36",
            "GF & Podium [D]": "4,107",
            "Tower 1 [E]": "22,100",
            "Tower 2 [F]": "35,339",
            "Tower 3 [G]": "29,314",
            "Tower 4 [H]": "30,077",
            "TOTAL QTY [I]": "120,973",
            "BASEMENTS [M]": "5,040.00",
            "GF & PODIUM [N]": "574,980.00",
            "TOWER 1 [O]": "3,094,000.00",
            "TOWER 2 [P]": "4,947,460.00",
            "TOWER 3 [Q]": "4,103,960.00",
            "TOWER 4 [R]": "4,210,780.00",
            "[S]": "TRUE",
            "[T]": "1116780"
          }
        },
        {
          "id": "2 - Main/423-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to lighting switch/sensor points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to lighting switch/sensor points",
          "quantity": 36423,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 9105750,
          "amount_state": "number",
          "printed_page": "2/R/124",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21878
          },
          "extra_columns": {
            "Basement [C]": "270",
            "GF & Podium [D]": "1,603",
            "Tower 1 [E]": "7,925",
            "Tower 2 [F]": "9,716",
            "Tower 3 [G]": "8,362",
            "Tower 4 [H]": "8,547",
            "TOTAL QTY [I]": "36,423",
            "BASEMENTS [M]": "67,500.00",
            "GF & PODIUM [N]": "400,750.00",
            "TOWER 1 [O]": "1,981,250.00",
            "TOWER 2 [P]": "2,429,000.00",
            "TOWER 3 [Q]": "2,090,500.00",
            "TOWER 4 [R]": "2,136,750.00",
            "[S]": "TRUE",
            "[T]": "155500"
          }
        },
        {
          "id": "2 - Main/423-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to LCP point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to LCP point",
          "quantity": 209,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 209000,
          "amount_state": "number",
          "printed_page": "2/R/124",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21880
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "41",
            "Tower 1 [E]": "33",
            "Tower 2 [F]": "41",
            "Tower 3 [G]": "40",
            "Tower 4 [H]": "36",
            "TOTAL QTY [I]": "209",
            "BASEMENTS [M]": "18,000.00",
            "GF & PODIUM [N]": "41,000.00",
            "TOWER 1 [O]": "33,000.00",
            "TOWER 2 [P]": "41,000.00",
            "TOWER 3 [Q]": "40,000.00",
            "TOWER 4 [R]": "36,000.00",
            "[S]": "TRUE",
            "[T]": "3000"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/424",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2599238,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/424-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 1.2; 10W, LED recessed ceiling downlight with COB LED module, 1000lm, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 1.2; 10W, LED recessed ceiling downlight with COB LED module, 1000lm, 3000K, IP65",
          "quantity": 40,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 6880,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21908
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/424-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 2.1; 36W, LED recessed ceiling 60x60 panel, 600mmx600mm steel, 3600lm, 4000K, IP40",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 2.1; 36W, LED recessed ceiling 60x60 panel, 600mmx600mm steel, 3600lm, 4000K, IP40",
          "quantity": 1017,
          "unit": "Nr.",
          "rate_aed": 214,
          "amount_aed": 217638,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21910
          },
          "extra_columns": {
            "Basement [C]": "32",
            "GF & Podium [D]": "186",
            "Tower 1 [E]": "194",
            "Tower 2 [F]": "204",
            "Tower 3 [G]": "215",
            "Tower 4 [H]": "186",
            "TOTAL QTY [I]": "1,017",
            "BASEMENTS [M]": "6,848.00",
            "GF & PODIUM [N]": "39,804.00",
            "TOWER 1 [O]": "41,516.00",
            "TOWER 2 [P]": "43,656.00",
            "TOWER 3 [Q]": "46,010.00",
            "TOWER 4 [R]": "39,804.00",
            "[S]": "TRUE",
            "[T]": "-1712"
          }
        },
        {
          "id": "2 - Main/424-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 3.1; 25W, LED ceiling mounted downlight, 2250lm, 4000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 3.1; 25W, LED ceiling mounted downlight, 2250lm, 4000K, IP65",
          "quantity": 1033,
          "unit": "Nr.",
          "rate_aed": 208,
          "amount_aed": 214864,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21912
          },
          "extra_columns": {
            "Basement [C]": "52",
            "GF & Podium [D]": "124",
            "Tower 1 [E]": "197",
            "Tower 2 [F]": "228",
            "Tower 3 [G]": "224",
            "Tower 4 [H]": "208",
            "TOTAL QTY [I]": "1,033",
            "BASEMENTS [M]": "10,816.00",
            "GF & PODIUM [N]": "25,792.00",
            "TOWER 1 [O]": "40,976.00",
            "TOWER 2 [P]": "47,424.00",
            "TOWER 3 [Q]": "46,592.00",
            "TOWER 4 [R]": "43,264.00",
            "[S]": "TRUE",
            "[T]": "2288"
          }
        },
        {
          "id": "2 - Main/424-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 4.1; 30W, LED linear ceiling mounted light, 4200lm, 4000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 4.1; 30W, LED linear ceiling mounted light, 4200lm, 4000K, IP65",
          "quantity": 2149,
          "unit": "Nr.",
          "rate_aed": 226,
          "amount_aed": 485674,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21914
          },
          "extra_columns": {
            "Basement [C]": "686",
            "GF & Podium [D]": "771",
            "Tower 1 [E]": "146",
            "Tower 2 [F]": "206",
            "Tower 3 [G]": "164",
            "Tower 4 [H]": "176",
            "TOTAL QTY [I]": "2,149",
            "BASEMENTS [M]": "155,036.00",
            "GF & PODIUM [N]": "174,246.00",
            "TOWER 1 [O]": "32,996.00",
            "TOWER 2 [P]": "46,556.00",
            "TOWER 3 [Q]": "37,064.00",
            "TOWER 4 [R]": "39,776.00",
            "[S]": "TRUE",
            "[T]": "6780"
          }
        },
        {
          "id": "2 - Main/424-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 4.2; 35W + inbuilt sensor, LED linear ceiling mounted light, 4550lm, 4000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 4.2; 35W + inbuilt sensor, LED linear ceiling mounted light, 4550lm, 4000K, IP65",
          "quantity": 1161,
          "unit": "Nr.",
          "rate_aed": 261,
          "amount_aed": 303021,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21916
          },
          "extra_columns": {
            "Basement [C]": "706",
            "GF & Podium [D]": "455",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,161",
            "BASEMENTS [M]": "184,266.00",
            "GF & PODIUM [N]": "118,755.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/424-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 3.2, located at roof deck",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 3.2, located at roof deck",
          "quantity": 64,
          "unit": "Nr.",
          "rate_aed": 214,
          "amount_aed": 13696,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21918
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "22",
            "Tower 3 [G]": "21",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,708.00",
            "TOWER 3 [Q]": "4,494.00",
            "TOWER 4 [R]": "4,494.00",
            "[S]": "TRUE",
            "[T]": "4494"
          }
        },
        {
          "id": "2 - Main/424-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type LTB 3.3, located at lifts",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type LTB 3.3, located at lifts",
          "quantity": 1633,
          "unit": "Nr.",
          "rate_aed": 214,
          "amount_aed": 349462,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21920
          },
          "extra_columns": {
            "Basement [C]": "56",
            "GF & Podium [D]": "113",
            "Tower 1 [E]": "351",
            "Tower 2 [F]": "385",
            "Tower 3 [G]": "371",
            "Tower 4 [H]": "357",
            "TOTAL QTY [I]": "1,633",
            "BASEMENTS [M]": "11,984.00",
            "GF & PODIUM [N]": "24,182.00",
            "TOWER 1 [O]": "75,114.00",
            "TOWER 2 [P]": "82,390.00",
            "TOWER 3 [Q]": "79,394.00",
            "TOWER 4 [R]": "76,398.00",
            "[S]": "TRUE",
            "[T]": "1284"
          }
        },
        {
          "id": "2 - Main/424-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "BOH lighting"
          ],
          "own_description": "Type SL-74, located at washrooms",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — BOH lighting — Type SL-74, located at washrooms",
          "quantity": 245,
          "unit": "Nr.",
          "rate_aed": 523,
          "amount_aed": 128135,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21922
          },
          "extra_columns": {
            "Basement [C]": "11",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "57",
            "Tower 3 [G]": "57",
            "Tower 4 [H]": "53",
            "TOTAL QTY [I]": "245",
            "BASEMENTS [M]": "5,753.00",
            "GF & PODIUM [N]": "9,937.00",
            "TOWER 1 [O]": "25,104.00",
            "TOWER 2 [P]": "29,811.00",
            "TOWER 3 [Q]": "29,811.00",
            "TOWER 4 [R]": "27,719.00",
            "[S]": "TRUE",
            "[T]": "2615"
          }
        },
        {
          "id": "2 - Main/424-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.1a; 20W, ceiling recessed wide beam downlight - adjustable, 1800lm, 24° beam angle, 3000K, DALI control, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.1a; 20W, ceiling recessed wide beam downlight - adjustable, 1800lm, 24° beam angle, 3000K, DALI control, IP65",
          "quantity": 98,
          "unit": "Nr.",
          "rate_aed": 208,
          "amount_aed": 20384,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21926
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "98",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,384.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/424-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.2; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.2; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 2580,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21928
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,580.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/424-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.2a; 10W, ceiling recessed medium beam downlight - adjustable, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.2a; 10W, ceiling recessed medium beam downlight - adjustable, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "quantity": 186,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 31992,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21930
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "186",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "186",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,992.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/424-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.3; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.3; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP44",
          "quantity": 4796,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 824912,
          "amount_state": "number",
          "printed_page": "2/R/125",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21932
          },
          "extra_columns": {
            "Basement [C]": "50",
            "GF & Podium [D]": "288",
            "Tower 1 [E]": "1,025",
            "Tower 2 [F]": "1,204",
            "Tower 3 [G]": "1,113",
            "Tower 4 [H]": "1,116",
            "TOTAL QTY [I]": "4,796",
            "BASEMENTS [M]": "8,600.00",
            "GF & PODIUM [N]": "49,536.00",
            "TOWER 1 [O]": "176,300.00",
            "TOWER 2 [P]": "207,088.00",
            "TOWER 3 [Q]": "191,436.00",
            "TOWER 4 [R]": "191,952.00",
            "[S]": "TRUE",
            "[T]": "15652"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/425",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 863480,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/425-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.3x; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.3x; 10W, ceiling recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, DALI control, IP65",
          "quantity": 54,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 9288,
          "amount_state": "number",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21943
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "54",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,288.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 1.4; 10W, ceiling recessed medium beam downlight, 1000lm, 24° beam angle, 3000K, DALI control, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 1.4; 10W, ceiling recessed medium beam downlight, 1000lm, 24° beam angle, 3000K, DALI control, IP65",
          "quantity": 146,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 25112,
          "amount_state": "number",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21945
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "146",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "146",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,112.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 3.1; 10W, track mounted downlight, 3200lm, 60° beam angle, 6000K, DALI control, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 3.1; 10W, track mounted downlight, 3200lm, 60° beam angle, 6000K, DALI control, IP20",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 339,
          "amount_aed": 10848,
          "amount_state": "number",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21947
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,848.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 3.3; 8W, surface mounted medium beam mono-spot, 436lm, 36° beam angle, 3000K, DALI control, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 3.3; 8W, surface mounted medium beam mono-spot, 436lm, 36° beam angle, 3000K, DALI control, IP20",
          "quantity": 2648,
          "unit": "Nr.",
          "rate_aed": 309,
          "amount_aed": 818232,
          "amount_state": "number",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21949
          },
          "extra_columns": {
            "Basement [C]": "24",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "560",
            "Tower 2 [F]": "656",
            "Tower 3 [G]": "608",
            "Tower 4 [H]": "608",
            "TOTAL QTY [I]": "2,648",
            "BASEMENTS [M]": "7,416.00",
            "GF & PODIUM [N]": "59,328.00",
            "TOWER 1 [O]": "173,040.00",
            "TOWER 2 [P]": "202,704.00",
            "TOWER 3 [Q]": "187,872.00",
            "TOWER 4 [R]": "187,872.00",
            "[S]": "TRUE",
            "[T]": "14832"
          }
        },
        {
          "id": "2 - Main/425-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-101; seating pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-101; seating pendant (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21951
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-102; above table pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-102; above table pendant (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21953
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-103; reception pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-103; reception pendant (by ID)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21955
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-104; lounge 1 pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-104; lounge 1 pendant (by ID)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21957
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-105; pendant above reception (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-105; pendant above reception (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21959
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-106; pendant above dining and seating (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-106; pendant above dining and seating (by ID)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21961
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-107; pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-107; pendant (by ID)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21963
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-108; pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-108; pendant (by ID)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21965
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-109; pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-109; pendant (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21967
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-110; pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-110; pendant (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21969
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type PL-111; pendant (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type PL-111; pendant (by ID)",
          "quantity": 62,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21971
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "62",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "62",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/425-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-101; wall light behind reception desk (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-101; wall light behind reception desk (by ID)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "By Others",
          "amount_state": "text",
          "printed_page": "2/R/126",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21973
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/426",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 4442392,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/426-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-102; wall light above console-ivory and glass (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-102; wall light above console-ivory and glass (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 1188,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,188.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-103; console table lamp (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-103; console table lamp (by ID)",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 3564,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,564.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-104; seating area floor lamp (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-104; seating area floor lamp (by ID)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 2376,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,376.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-106; artwork wall lights (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-106; artwork wall lights (by ID)",
          "quantity": 1102,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 654588,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21992
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "82",
            "Tower 1 [E]": "236",
            "Tower 2 [F]": "274",
            "Tower 3 [G]": "256",
            "Tower 4 [H]": "254",
            "TOTAL QTY [I]": "1,102",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,708.00",
            "TOWER 1 [O]": "140,184.00",
            "TOWER 2 [P]": "162,756.00",
            "TOWER 3 [Q]": "152,064.00",
            "TOWER 4 [R]": "150,876.00",
            "[S]": "TRUE",
            "[T]": "10692"
          }
        },
        {
          "id": "2 - Main/426-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-107; floor lamp (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-107; floor lamp (by ID)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 1188,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21994
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,188.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-108; table lamp (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-108; table lamp (by ID)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 2376,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21996
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,376.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LI-110; wall light (by ID)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LI-110; wall light (by ID)",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 594,
          "amount_aed": 10692,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 21998
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "18",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,692.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 2.1; 10W/m, LED strip in linear profile with diffuser, 950lm/m, 90° beam angle, 3000K, DALI control, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 2.1; 10W/m, LED strip in linear profile with diffuser, 950lm/m, 90° beam angle, 3000K, DALI control, IP65",
          "quantity": 15,
          "unit": "m",
          "rate_aed": 190,
          "amount_aed": 2850,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22000
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 2.2; 10W/m, LED strip in linear profile with diffuser, 950lm/m, 90° beam angle, 3000K, DALI control, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 2.2; 10W/m, LED strip in linear profile with diffuser, 950lm/m, 90° beam angle, 3000K, DALI control, IP20",
          "quantity": 4731,
          "unit": "m",
          "rate_aed": 190,
          "amount_aed": 898890,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22002
          },
          "extra_columns": {
            "Basement [C]": "36",
            "GF & Podium [D]": "1,031",
            "Tower 1 [E]": "844",
            "Tower 2 [F]": "988",
            "Tower 3 [G]": "916",
            "Tower 4 [H]": "916",
            "TOTAL QTY [I]": "4,731",
            "BASEMENTS [M]": "6,840.00",
            "GF & PODIUM [N]": "195,890.00",
            "TOWER 1 [O]": "160,360.00",
            "TOWER 2 [P]": "187,720.00",
            "TOWER 3 [Q]": "174,040.00",
            "TOWER 4 [R]": "174,040.00",
            "[S]": "TRUE",
            "[T]": "13680"
          }
        },
        {
          "id": "2 - Main/426-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "FOH lighting"
          ],
          "own_description": "Type LTP 3.2; 10W/m, recessed linear light, 1000lm/m, diffused beam, 3000K, DALI control, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — FOH lighting — Type LTP 3.2; 10W/m, recessed linear light, 1000lm/m, diffused beam, 3000K, DALI control, IP20",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 350,
          "amount_aed": 11200,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22004
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/426-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 1.1; 10W, recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 1.1; 10W, recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, IP44",
          "quantity": 6531,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 1123332,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22008
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "186",
            "Tower 1 [E]": "1,351",
            "Tower 2 [F]": "1,866",
            "Tower 3 [G]": "1,512",
            "Tower 4 [H]": "1,616",
            "TOTAL QTY [I]": "6,531",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,992.00",
            "TOWER 1 [O]": "232,372.00",
            "TOWER 2 [P]": "320,952.00",
            "TOWER 3 [Q]": "260,064.00",
            "TOWER 4 [R]": "277,952.00",
            "[S]": "TRUE",
            "[T]": "45580"
          }
        },
        {
          "id": "2 - Main/426-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 1.2; 10W, recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 1.2; 10W, recessed medium beam downlight, 1000lm, 36° beam angle, 3000K, IP44",
          "quantity": 6394,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 1099768,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22010
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "227",
            "Tower 1 [E]": "1,445",
            "Tower 2 [F]": "1,535",
            "Tower 3 [G]": "1,667",
            "Tower 4 [H]": "1,520",
            "TOTAL QTY [I]": "6,394",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,044.00",
            "TOWER 1 [O]": "248,540.00",
            "TOWER 2 [P]": "264,020.00",
            "TOWER 3 [Q]": "286,724.00",
            "TOWER 4 [R]": "261,440.00",
            "[S]": "TRUE",
            "[T]": "12900"
          }
        },
        {
          "id": "2 - Main/426-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 1.3; 10W, recessed wide beam downlight, 1000lm, 60° beam angle, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 1.3; 10W, recessed wide beam downlight, 1000lm, 60° beam angle, 3000K, IP65",
          "quantity": 3665,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 630380,
          "amount_state": "number",
          "printed_page": "2/R/127",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22012
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "114",
            "Tower 1 [E]": "813",
            "Tower 2 [F]": "939",
            "Tower 3 [G]": "918",
            "Tower 4 [H]": "881",
            "TOTAL QTY [I]": "3,665",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,608.00",
            "TOWER 1 [O]": "139,836.00",
            "TOWER 2 [P]": "161,508.00",
            "TOWER 3 [Q]": "157,896.00",
            "TOWER 4 [R]": "151,532.00",
            "[S]": "TRUE",
            "[T]": "11696"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/427",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 12205525,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/427-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 1.4; 10W, recessed narrow beam downlight, 1000lm, 24° beam angle, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 1.4; 10W, recessed narrow beam downlight, 1000lm, 24° beam angle, 3000K, IP65",
          "quantity": 3955,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 680260,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22030
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "128",
            "Tower 1 [E]": "908",
            "Tower 2 [F]": "973",
            "Tower 3 [G]": "1,019",
            "Tower 4 [H]": "927",
            "TOTAL QTY [I]": "3,955",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,016.00",
            "TOWER 1 [O]": "156,176.00",
            "TOWER 2 [P]": "167,356.00",
            "TOWER 3 [Q]": "175,268.00",
            "TOWER 4 [R]": "159,444.00",
            "[S]": "TRUE",
            "[T]": "3268"
          }
        },
        {
          "id": "2 - Main/427-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 3.1; 18W, ceiling surface mounted light, 1600lm, diffused beam, 3000K, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 3.1; 18W, ceiling surface mounted light, 1600lm, diffused beam, 3000K, IP44",
          "quantity": 5142,
          "unit": "Nr.",
          "rate_aed": 178,
          "amount_aed": 915276,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22032
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "161",
            "Tower 1 [E]": "1,133",
            "Tower 2 [F]": "1,339",
            "Tower 3 [G]": "1,273",
            "Tower 4 [H]": "1,236",
            "TOTAL QTY [I]": "5,142",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,658.00",
            "TOWER 1 [O]": "201,674.00",
            "TOWER 2 [P]": "238,342.00",
            "TOWER 3 [Q]": "226,594.00",
            "TOWER 4 [R]": "220,008.00",
            "[S]": "TRUE",
            "[T]": "18334"
          }
        },
        {
          "id": "2 - Main/427-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 4.1; 18W, wall mounted light, 1500lm, 120° beam angle, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 4.1; 18W, wall mounted light, 1500lm, 120° beam angle, 3000K, IP65",
          "quantity": 1745,
          "unit": "Nr.",
          "rate_aed": 261,
          "amount_aed": 455445,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22034
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,745",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,921.00",
            "TOWER 1 [O]": "105,705.00",
            "TOWER 2 [P]": "108,054.00",
            "TOWER 3 [Q]": "118,494.00",
            "TOWER 4 [R]": "107,271.00",
            "[S]": "TRUE",
            "[T]": "1566"
          }
        },
        {
          "id": "2 - Main/427-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 4.2; 18W, surface mounted LED light, 1600lm, 120° beam angle, 3000K, IP44",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 4.2; 18W, surface mounted LED light, 1600lm, 120° beam angle, 3000K, IP44",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 261,
          "amount_aed": 522,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22036
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "261.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "261.00",
            "[S]": "TRUE",
            "[T]": "261"
          }
        },
        {
          "id": "2 - Main/427-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 5.1; 10W, recessed medium beam downlight, 1000lm, 24° beam angle, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 5.1; 10W, recessed medium beam downlight, 1000lm, 24° beam angle, 3000K, IP65",
          "quantity": 3538,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 608536,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22038
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "128",
            "Tower 1 [E]": "766",
            "Tower 2 [F]": "931",
            "Tower 3 [G]": "861",
            "Tower 4 [H]": "852",
            "TOTAL QTY [I]": "3,538",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,016.00",
            "TOWER 1 [O]": "131,752.00",
            "TOWER 2 [P]": "160,132.00",
            "TOWER 3 [Q]": "148,092.00",
            "TOWER 4 [R]": "146,544.00",
            "[S]": "TRUE",
            "[T]": "14792"
          }
        },
        {
          "id": "2 - Main/427-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 2.1; 10W/m, LED strip in profile, 950lm/m, 90° beam angle, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 2.1; 10W/m, LED strip in profile, 950lm/m, 90° beam angle, 3000K, IP65",
          "quantity": 16112,
          "unit": "m",
          "rate_aed": 71,
          "amount_aed": 1143952,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22040
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "562",
            "Tower 1 [E]": "3,763",
            "Tower 2 [F]": "3,933",
            "Tower 3 [G]": "4,070",
            "Tower 4 [H]": "3,784",
            "TOTAL QTY [I]": "16,112",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,902.00",
            "TOWER 1 [O]": "267,173.00",
            "TOWER 2 [P]": "279,243.00",
            "TOWER 3 [Q]": "288,970.00",
            "TOWER 4 [R]": "268,664.00",
            "[S]": "TRUE",
            "[T]": "1491"
          }
        },
        {
          "id": "2 - Main/427-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "Type LTA 2.2; 10W/m, LED strip in profile, 920lm/m, 90° beam angle, 3000K, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — Type LTA 2.2; 10W/m, LED strip in profile, 920lm/m, 90° beam angle, 3000K, IP20",
          "quantity": 100274,
          "unit": "m",
          "rate_aed": 71,
          "amount_aed": 7119454,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22042
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2,464",
            "Tower 1 [E]": "17,493",
            "Tower 2 [F]": "30,417",
            "Tower 3 [G]": "24,523",
            "Tower 4 [H]": "25,377",
            "TOTAL QTY [I]": "100,274",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "174,944.00",
            "TOWER 1 [O]": "1,242,003.00",
            "TOWER 2 [P]": "2,159,607.00",
            "TOWER 3 [Q]": "1,741,133.00",
            "TOWER 4 [R]": "1,801,767.00",
            "[S]": "TRUE",
            "[T]": "559764"
          }
        },
        {
          "id": "2 - Main/427-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification",
            "Apartment lighting"
          ],
          "own_description": "ID lightings; fixed decorative lights such as pendant lights, chandelier lights, picture lights to FOH areas - Supply by Emaar; Contractor to allow for storage, protection and installation of ID lightings",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, accessories and all ancillary works as necessary; as specialist lighting specification — Apartment lighting — ID lightings; fixed decorative lights such as pendant lights, chandelier lights, picture lights to FOH areas - Supply by Emaar; Contractor to allow for storage, protection and installation of ID lightings",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 200000,
          "amount_aed": 200000,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22044
          },
          "extra_columns": {
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/427-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 gang 1 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 1 gang 1 way light switch",
          "quantity": 3346,
          "unit": "Nr.",
          "rate_aed": 45,
          "amount_aed": 150570,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22048
          },
          "extra_columns": {
            "Basement [C]": "37",
            "GF & Podium [D]": "197",
            "Tower 1 [E]": "601",
            "Tower 2 [F]": "868",
            "Tower 3 [G]": "824",
            "Tower 4 [H]": "819",
            "TOTAL QTY [I]": "3,346",
            "BASEMENTS [M]": "1,665.00",
            "GF & PODIUM [N]": "8,865.00",
            "TOWER 1 [O]": "27,045.00",
            "TOWER 2 [P]": "39,060.00",
            "TOWER 3 [Q]": "37,080.00",
            "TOWER 4 [R]": "36,855.00",
            "[S]": "TRUE",
            "[T]": "9810"
          }
        },
        {
          "id": "2 - Main/427-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 gang 1 way light switch, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 1 gang 1 way light switch, weatherproof",
          "quantity": 37,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22050
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "2,240.00",
            "GF & PODIUM [N]": "1,600.00",
            "TOWER 1 [O]": "640.00",
            "TOWER 2 [P]": "480.00",
            "TOWER 3 [Q]": "480.00",
            "TOWER 4 [R]": "480.00",
            "[S]": "TRUE",
            "[T]": "-160"
          }
        },
        {
          "id": "2 - Main/427-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 gang 2 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 1 gang 2 way light switch",
          "quantity": 3558,
          "unit": "Nr.",
          "rate_aed": 45,
          "amount_aed": 160110,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22052
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "137",
            "Tower 1 [E]": "990",
            "Tower 2 [F]": "818",
            "Tower 3 [G]": "829",
            "Tower 4 [H]": "778",
            "TOTAL QTY [I]": "3,558",
            "BASEMENTS [M]": "270.00",
            "GF & PODIUM [N]": "6,165.00",
            "TOWER 1 [O]": "44,550.00",
            "TOWER 2 [P]": "36,810.00",
            "TOWER 3 [Q]": "37,305.00",
            "TOWER 4 [R]": "35,010.00",
            "[S]": "TRUE",
            "[T]": "-9540"
          }
        },
        {
          "id": "2 - Main/427-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 gang 2 way light switch, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 1 gang 2 way light switch, weatherproof",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 180,
          "amount_aed": 1080,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22054
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "360"
          }
        },
        {
          "id": "2 - Main/427-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "2 gang 1 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 2 gang 1 way light switch",
          "quantity": 4522,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 293930,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22056
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "126",
            "Tower 1 [E]": "987",
            "Tower 2 [F]": "1,202",
            "Tower 3 [G]": "1,119",
            "Tower 4 [H]": "1,088",
            "TOTAL QTY [I]": "4,522",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,190.00",
            "TOWER 1 [O]": "64,155.00",
            "TOWER 2 [P]": "78,130.00",
            "TOWER 3 [Q]": "72,735.00",
            "TOWER 4 [R]": "70,720.00",
            "[S]": "TRUE",
            "[T]": "6565"
          }
        },
        {
          "id": "2 - Main/427-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "2 gang 2 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 2 gang 2 way light switch",
          "quantity": 4449,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 289185,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22058
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "137",
            "Tower 1 [E]": "957",
            "Tower 2 [F]": "1,144",
            "Tower 3 [G]": "1,123",
            "Tower 4 [H]": "1,088",
            "TOTAL QTY [I]": "4,449",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,905.00",
            "TOWER 1 [O]": "62,205.00",
            "TOWER 2 [P]": "74,360.00",
            "TOWER 3 [Q]": "72,995.00",
            "TOWER 4 [R]": "70,720.00",
            "[S]": "TRUE",
            "[T]": "8515"
          }
        },
        {
          "id": "2 - Main/427-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "3 gang 1 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 3 gang 1 way light switch",
          "quantity": 1194,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 77610,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22060
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "274",
            "Tower 2 [F]": "299",
            "Tower 3 [G]": "304",
            "Tower 4 [H]": "273",
            "TOTAL QTY [I]": "1,194",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,860.00",
            "TOWER 1 [O]": "17,810.00",
            "TOWER 2 [P]": "19,435.00",
            "TOWER 3 [Q]": "19,760.00",
            "TOWER 4 [R]": "17,745.00",
            "[S]": "TRUE",
            "[T]": "-65"
          }
        },
        {
          "id": "2 - Main/427-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "3 gang 2 way light switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — 3 gang 2 way light switch",
          "quantity": 1595,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 103675,
          "amount_state": "number",
          "printed_page": "2/R/128",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22062
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "56",
            "Tower 1 [E]": "367",
            "Tower 2 [F]": "380",
            "Tower 3 [G]": "407",
            "Tower 4 [H]": "385",
            "TOTAL QTY [I]": "1,595",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,640.00",
            "TOWER 1 [O]": "23,855.00",
            "TOWER 2 [P]": "24,700.00",
            "TOWER 3 [Q]": "26,455.00",
            "TOWER 4 [R]": "25,025.00",
            "[S]": "TRUE",
            "[T]": "1170"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/428",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 4846576,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/428-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Bell push",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Bell push",
          "quantity": 1745,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 209400,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22075
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,745",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,320.00",
            "TOWER 1 [O]": "48,600.00",
            "TOWER 2 [P]": "49,680.00",
            "TOWER 3 [Q]": "54,480.00",
            "TOWER 4 [R]": "49,320.00",
            "[S]": "TRUE",
            "[T]": "720"
          }
        },
        {
          "id": "2 - Main/428-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Control plate",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Control plate",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22077
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Door bell",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Door bell",
          "quantity": 1745,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 226850,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22079
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "405",
            "Tower 2 [F]": "414",
            "Tower 3 [G]": "454",
            "Tower 4 [H]": "411",
            "TOTAL QTY [I]": "1,745",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,930.00",
            "TOWER 1 [O]": "52,650.00",
            "TOWER 2 [P]": "53,820.00",
            "TOWER 3 [Q]": "59,020.00",
            "TOWER 4 [R]": "53,430.00",
            "[S]": "TRUE",
            "[T]": "780"
          }
        },
        {
          "id": "2 - Main/428-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "LED driver",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — LED driver",
          "quantity": 388,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 92344,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22081
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "103",
            "Tower 3 [G]": "97",
            "Tower 4 [H]": "97",
            "TOTAL QTY [I]": "388",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "21,658.00",
            "TOWER 2 [P]": "24,514.00",
            "TOWER 3 [Q]": "23,086.00",
            "TOWER 4 [R]": "23,086.00",
            "[S]": "TRUE",
            "[T]": "1428"
          }
        },
        {
          "id": "2 - Main/428-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "LED strip driver",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — LED strip driver",
          "quantity": 3291,
          "unit": "Nr.",
          "rate_aed": 238,
          "amount_aed": 783258,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22083
          },
          "extra_columns": {
            "Basement [C]": "2",
            "GF & Podium [D]": "149",
            "Tower 1 [E]": "728",
            "Tower 2 [F]": "1,028",
            "Tower 3 [G]": "610",
            "Tower 4 [H]": "774",
            "TOTAL QTY [I]": "3,291",
            "BASEMENTS [M]": "476.00",
            "GF & PODIUM [N]": "35,462.00",
            "TOWER 1 [O]": "173,264.00",
            "TOWER 2 [P]": "244,664.00",
            "TOWER 3 [Q]": "145,180.00",
            "TOWER 4 [R]": "184,212.00",
            "[S]": "TRUE",
            "[T]": "10948"
          }
        },
        {
          "id": "2 - Main/428-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Micro switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Micro switch",
          "quantity": 6173,
          "unit": "Nr.",
          "rate_aed": 40,
          "amount_aed": 246920,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22085
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "176",
            "Tower 1 [E]": "1,264",
            "Tower 2 [F]": "1,611",
            "Tower 3 [G]": "1,622",
            "Tower 4 [H]": "1,500",
            "TOTAL QTY [I]": "6,173",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,040.00",
            "TOWER 1 [O]": "50,560.00",
            "TOWER 2 [P]": "64,440.00",
            "TOWER 3 [Q]": "64,880.00",
            "TOWER 4 [R]": "60,000.00",
            "[S]": "TRUE",
            "[T]": "9440"
          }
        },
        {
          "id": "2 - Main/428-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Motion sensor",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Motion sensor",
          "quantity": 151,
          "unit": "Nr.",
          "rate_aed": 650,
          "amount_aed": 98150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22087
          },
          "extra_columns": {
            "Basement [C]": "127",
            "GF & Podium [D]": "24",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "151",
            "BASEMENTS [M]": "82,550.00",
            "GF & PODIUM [N]": "15,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Override switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — Override switch",
          "quantity": 976,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 63440,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22089
          },
          "extra_columns": {
            "Basement [C]": "37",
            "GF & Podium [D]": "95",
            "Tower 1 [E]": "193",
            "Tower 2 [F]": "227",
            "Tower 3 [G]": "216",
            "Tower 4 [H]": "208",
            "TOTAL QTY [I]": "976",
            "BASEMENTS [M]": "2,405.00",
            "GF & PODIUM [N]": "6,175.00",
            "TOWER 1 [O]": "12,545.00",
            "TOWER 2 [P]": "14,755.00",
            "TOWER 3 [Q]": "14,040.00",
            "TOWER 4 [R]": "13,520.00",
            "[S]": "TRUE",
            "[T]": "975"
          }
        },
        {
          "id": "2 - Main/428-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "PIR sensor",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — PIR sensor",
          "quantity": 3208,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 2726800,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22091
          },
          "extra_columns": {
            "Basement [C]": "47",
            "GF & Podium [D]": "319",
            "Tower 1 [E]": "659",
            "Tower 2 [F]": "1,203",
            "Tower 3 [G]": "270",
            "Tower 4 [H]": "710",
            "TOTAL QTY [I]": "3,208",
            "BASEMENTS [M]": "39,950.00",
            "GF & PODIUM [N]": "271,150.00",
            "TOWER 1 [O]": "560,150.00",
            "TOWER 2 [P]": "1,022,550.00",
            "TOWER 3 [Q]": "229,500.00",
            "TOWER 4 [R]": "603,500.00",
            "[S]": "TRUE",
            "[T]": "43350"
          }
        },
        {
          "id": "2 - Main/428-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "LED strip driver for 1BR-A unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — LED strip driver for 1BR-A unit",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 178500,
          "amount_aed": 178500,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22093
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "178,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/428-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "LED strip driver for 2BR-C unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Lighting controls; including fixings, supports, hangers, accessories and all ancillary works as necessary — LED strip driver for 2BR-C unit",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 179214,
          "amount_aed": 179214,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22095
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "179,214.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/428-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22099
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22101
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-B1-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-B1-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22103
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22105
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22107
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22109
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22111
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/428-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/129",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22113
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/429",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/429-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22127
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-GF-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-GF-LV-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22129
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-GF-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-GF-LV-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22131
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22133
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22135
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22137
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22139
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22141
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22143
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-01-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-01-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22145
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22147
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22149
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22151
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22153
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-02-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-02-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22155
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22157
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22159
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22161
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22163
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22165
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22167
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/429-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-04-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/130",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22169
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/430",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/430-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-07-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22181
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-10-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22183
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-13-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22185
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-16-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-19-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22189
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-22-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22191
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-25-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22193
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-28-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22195
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22197
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-31-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22199
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-34-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22201
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-37-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-40-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22205
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-43-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-46-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T1-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T1-49-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/430-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-04-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/430-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-07-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/430-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-10-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22217
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/430-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-13-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22219
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/430-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-16-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22221
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/430-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-19-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/131",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22223
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/431",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/431-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-22-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22235
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-25-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22237
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-28-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22239
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22241
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-31-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22243
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-34-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22245
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-37-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22247
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-40-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22249
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-43-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22251
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-46-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22253
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-48-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22255
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-49-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22257
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-52-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22259
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-55-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22261
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T2-58-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T2-58-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22263
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-04-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22265
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-07-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22267
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-10-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22269
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-13-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22271
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-16-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22273
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-19-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22275
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/431-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-22-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/132",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22277
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/432",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 72450,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/432-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-25-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22289
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-28-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22291
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22293
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-31-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22295
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-34-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22297
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-37-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22299
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-40-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22301
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-43-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22303
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-46-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22305
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-49-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22307
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-52-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22309
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T3-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T3-55-LL01",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22311
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,300.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/432-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-04-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22313
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-07-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-07-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22315
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-10-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-10-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22317
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-13-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-13-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22319
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-16-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-16-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22321
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-19-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-19-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22323
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-22-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-22-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22325
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-25-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-25-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22327
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-28-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-28-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22329
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/432-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-30-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-30-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/133",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22331
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/433",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/433-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-31-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-31-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22343
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-34-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-34-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22345
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-37-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-37-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22347
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-40-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-40-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22349
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-43-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-43-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22351
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-46-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-46-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22353
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-49-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-49-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22355
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-52-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-52-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22357
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "ELCP-T4-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — ELCP-T4-55-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22359
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/433-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22361
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22363
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-B1-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-B1-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22365
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22367
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-B1-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-B1-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22369
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22371
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22373
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22375
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-B2-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-B2-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22377
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "3,150.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-GV-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-GV-LV-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22379
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-GV-LV-01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-GV-LV-01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22381
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22383
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/433-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/134",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22385
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/434",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/434-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-GF-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-GF-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22397
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22399
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-GF-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-GF-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22401
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22403
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22405
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-01-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-01-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22407
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-01-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-01-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22411
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22413
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-02-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-02-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-02-LL02",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-02-LL02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-02-LL03",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-02-LL03",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22419
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-04-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-04-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22423
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-03-GYM",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-03-GYM",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22425
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22427
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22431
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-03-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-03-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/434-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-06-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/434-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-09-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22437
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/434-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-12-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/135",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22439
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/435",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/435-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-15-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22451
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-18-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22453
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-21-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22455
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-24-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22457
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-27-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22459
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22461
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-32-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22463
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-35-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22465
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-38-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22467
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-41-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22469
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-44-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-47-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22473
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T1-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T1-50-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22475
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,150.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-3150"
          }
        },
        {
          "id": "2 - Main/435-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-06-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22477
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-09-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22479
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-12-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22481
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-15-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22483
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-18-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22485
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-21-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-24-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-27-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22491
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/435-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/136",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22493
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/436",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/436-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-32-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22505
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-35-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22507
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-38-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22509
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-41-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22511
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-44-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22513
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-47-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22515
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-48-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22517
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-50-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22519
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-53-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22521
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-56-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-56-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22523
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T2-59-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T2-59-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22525
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "3,150.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-06-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22527
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-09-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22529
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-12-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22531
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-15-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22533
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-18-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22535
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-21-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22537
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-24-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22539
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-27-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22541
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22543
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-32-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-32-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22545
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/436-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-35-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-35-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/137",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22547
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/437",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 69300,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/437-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-38-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-38-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22559
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-41-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-41-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22561
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-44-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-44-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22563
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-47-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-47-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22565
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-50-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-50-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22567
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-53-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-53-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22569
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T3-54-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T3-54-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22571
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "3,150.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/437-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-06-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-06-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22573
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-09-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-09-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22575
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-12-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-12-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22577
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-15-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-15-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22579
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-18-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-18-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22581
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-21-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-21-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-24-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-24-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22585
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-27-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-27-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-R",
          "item_code": "R",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-29-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-29-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-S",
          "item_code": "S",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-33-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-33-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-T",
          "item_code": "T",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-36-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-36-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-U",
          "item_code": "U",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-39-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-39-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-V",
          "item_code": "V",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-42-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-42-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22597
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-W",
          "item_code": "W",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-45-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-45-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/437-X",
          "item_code": "X",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-48-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-48-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/138",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/438",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2054650,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/438-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-51-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-51-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/139",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22613
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/438-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "LCP-T4-55-LL01",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — LCP-T4-55-LL01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/139",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22615
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "3,150.00",
            "[S]": "TRUE",
            "[T]": "3150"
          }
        },
        {
          "id": "2 - Main/438-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Facade Lighting Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From LCP to facade lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Facade Lighting Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From LCP to facade lighting points",
          "quantity": 2362,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 590500,
          "amount_state": "number",
          "printed_page": "2/R/139",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22621
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "523",
            "Tower 2 [F]": "562",
            "Tower 3 [G]": "695",
            "Tower 4 [H]": "562",
            "TOTAL QTY [I]": "2,362",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "130,750.00",
            "TOWER 2 [P]": "140,500.00",
            "TOWER 3 [Q]": "173,750.00",
            "TOWER 4 [R]": "140,500.00",
            "[S]": "TRUE",
            "[T]": "9750"
          }
        },
        {
          "id": "2 - Main/438-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Facade Lighting Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From LCP to facade linear lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Facade Lighting Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From LCP to facade linear lighting points",
          "quantity": 9719,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 1457850,
          "amount_state": "number",
          "printed_page": "2/R/139",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22623
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,320",
            "Tower 1 [E]": "1,864",
            "Tower 2 [F]": "2,258",
            "Tower 3 [G]": "2,283",
            "Tower 4 [H]": "1,994",
            "TOTAL QTY [I]": "9,719",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "198,000.00",
            "TOWER 1 [O]": "279,600.00",
            "TOWER 2 [P]": "338,700.00",
            "TOWER 3 [Q]": "342,450.00",
            "TOWER 4 [R]": "299,100.00",
            "[S]": "TRUE",
            "[T]": "19500"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/439",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2645632,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/439-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 5.3m; 5W, recessed medium beam uplight, 490lm, 34° beam angle, 3000K, SWT control, IP67",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 5.3m; 5W, recessed medium beam uplight, 490lm, 34° beam angle, 3000K, SWT control, IP67",
          "quantity": 452,
          "unit": "Nr.",
          "rate_aed": 362,
          "amount_aed": 163624,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22663
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "86",
            "Tower 2 [F]": "97",
            "Tower 3 [G]": "172",
            "Tower 4 [H]": "97",
            "TOTAL QTY [I]": "452",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "31,132.00",
            "TOWER 2 [P]": "35,114.00",
            "TOWER 3 [Q]": "62,264.00",
            "TOWER 4 [R]": "35,114.00",
            "[S]": "TRUE",
            "[T]": "3982"
          }
        },
        {
          "id": "2 - Main/439-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 5.3n; 5W, recessed medium beam uplight, 490lm, 24° beam angle, 3000K, SWT control, IP67",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 5.3n; 5W, recessed medium beam uplight, 490lm, 24° beam angle, 3000K, SWT control, IP67",
          "quantity": 1890,
          "unit": "Nr.",
          "rate_aed": 362,
          "amount_aed": 684180,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22665
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "437",
            "Tower 2 [F]": "465",
            "Tower 3 [G]": "523",
            "Tower 4 [H]": "465",
            "TOTAL QTY [I]": "1,890",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "158,194.00",
            "TOWER 2 [P]": "168,330.00",
            "TOWER 3 [Q]": "189,326.00",
            "TOWER 4 [R]": "168,330.00",
            "[S]": "TRUE",
            "[T]": "10136"
          }
        },
        {
          "id": "2 - Main/439-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 6.1; 10W, recessed wide beam downlight, 650lm, 35° beam angle, 3000K, SWT control, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 6.1; 10W, recessed wide beam downlight, 650lm, 35° beam angle, 3000K, SWT control, IP65",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 172,
          "amount_aed": 2064,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22667
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,064.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/439-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 8.1; 20W, wall sconce, 1700lm, diffused beam, 3000K, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 8.1; 20W, wall sconce, 1700lm, diffused beam, 3000K, IP65",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 802,
          "amount_aed": 6416,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22669
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,416.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/439-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 3.2; 24W/m, inground linear grazer, 2040lm, 10°x45° beam angle, 3000K, SWT control, IP67",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 3.2; 24W/m, inground linear grazer, 2040lm, 10°x45° beam angle, 3000K, SWT control, IP67",
          "quantity": 766,
          "unit": "m",
          "rate_aed": 398,
          "amount_aed": 304868,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22671
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "766",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "766",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "304,868.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/439-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification"
          ],
          "own_description": "Type LTF 7.1; 10W/m, linear encapsulated LED - IP rated, 650lm, diffused beam, 3000K, IP67",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Luminaires; including fixings, supports, hangers, diffusers, drivers, lighting control sensors, accessories and all ancillary works as necessary; as specialist lighting specification — Type LTF 7.1; 10W/m, linear encapsulated LED - IP rated, 650lm, diffused beam, 3000K, IP67",
          "quantity": 9056,
          "unit": "m",
          "rate_aed": 160,
          "amount_aed": 1448960,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22673
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "553",
            "Tower 1 [E]": "1,864",
            "Tower 2 [F]": "2,258",
            "Tower 3 [G]": "2,387",
            "Tower 4 [H]": "1,994",
            "TOTAL QTY [I]": "9,056",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "88,480.00",
            "TOWER 1 [O]": "298,240.00",
            "TOWER 2 [P]": "361,280.00",
            "TOWER 3 [Q]": "381,920.00",
            "TOWER 4 [R]": "319,040.00",
            "[S]": "TRUE",
            "[T]": "20800"
          }
        },
        {
          "id": "2 - Main/439-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft Warning Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From 70 series LED controller to Hi flux LED point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft Warning Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From 70 series LED controller to Hi flux LED point",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5920,
          "amount_aed": 11840,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22679
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,920.00",
            "TOWER 2 [P]": "5,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5920"
          }
        },
        {
          "id": "2 - Main/439-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft Warning Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From 70 series LED controller to photocell point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft Warning Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From 70 series LED controller to photocell point",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5920,
          "amount_aed": 11840,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22681
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,920.00",
            "TOWER 2 [P]": "5,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5920"
          }
        },
        {
          "id": "2 - Main/439-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft Warning Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From DB to 70 series LED controller point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft Warning Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From DB to 70 series LED controller point",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5920,
          "amount_aed": 11840,
          "amount_state": "number",
          "printed_page": "2/R/140",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22683
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,920.00",
            "TOWER 2 [P]": "5,920.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-5920"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/440",
      "section": "LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 137760,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/440-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Hi flux LED medium intensity white flashing light built in GPS/PCELL",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Hi flux LED medium intensity white flashing light built in GPS/PCELL",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22699
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "25,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-25000"
          }
        },
        {
          "id": "2 - Main/440-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Photocell",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Photocell",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 10000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22701
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "10,000.00",
            "TOWER 2 [P]": "10,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-10000"
          }
        },
        {
          "id": "2 - Main/440-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary"
          ],
          "own_description": "70 series LED controller",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Equipment; including fixings, supports, hangers, interconnecting cables, interface connections, accessories and all ancillary works as necessary — 70 series LED controller",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22705
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "25,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-25000"
          }
        },
        {
          "id": "2 - Main/440-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "To BMS system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — To BMS system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5920,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22709
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/440-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Aircraft warning lighting at Tower 3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Aircraft warning lighting at Tower 3",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5920,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22711
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/440-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Aircraft warning lighting at Tower 4",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — LIGHTING INSTALLATION — Aircraft warning lighting interfacing works; complete including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Aircraft warning lighting at Tower 4",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5920,
          "amount_aed": 5920,
          "amount_state": "number",
          "printed_page": "2/R/141",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22713
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/441",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 6370580,
      "section_notes": [
        "Note: Refer to the following",
        "1. Fire Alarm and Voice Evacuation Drawing Nr. ZD-3250587-CKR-DWG-PDM-ELE-3000 to 3996, ZD-3250587-CKR-DWG-1B2-ELE-9125 to 9247, TW1-ELE-3040 to 3530,  TW2-ELE-3040 to 3610, TW3-ELE-3040 to 3570, TW4-ELE-3040 to 3570; all inclusive",
        "2. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/441-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to abort switch points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to abort switch points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22752
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/441-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to addressable heat detector with built-in isolator base points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to addressable heat detector with built-in isolator base points",
          "quantity": 2394,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 813960,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22754
          },
          "extra_columns": {
            "Basement [C]": "20",
            "GF & Podium [D]": "314",
            "Tower 1 [E]": "492",
            "Tower 2 [F]": "532",
            "Tower 3 [G]": "534",
            "Tower 4 [H]": "502",
            "TOTAL QTY [I]": "2,394",
            "BASEMENTS [M]": "6,800.00",
            "GF & PODIUM [N]": "106,760.00",
            "TOWER 1 [O]": "167,280.00",
            "TOWER 2 [P]": "180,880.00",
            "TOWER 3 [Q]": "181,560.00",
            "TOWER 4 [R]": "170,680.00",
            "[S]": "TRUE",
            "[T]": "3400"
          }
        },
        {
          "id": "2 - Main/441-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to addressable optical smoke detector with built-in isolator base points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to addressable optical smoke detector with built-in isolator base points",
          "quantity": 8799,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2991660,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22756
          },
          "extra_columns": {
            "Basement [C]": "107",
            "GF & Podium [D]": "501",
            "Tower 1 [E]": "1,824",
            "Tower 2 [F]": "2,151",
            "Tower 3 [G]": "2,168",
            "Tower 4 [H]": "2,048",
            "TOTAL QTY [I]": "8,799",
            "BASEMENTS [M]": "36,380.00",
            "GF & PODIUM [N]": "170,340.00",
            "TOWER 1 [O]": "620,160.00",
            "TOWER 2 [P]": "731,340.00",
            "TOWER 3 [Q]": "737,120.00",
            "TOWER 4 [R]": "696,320.00",
            "[S]": "TRUE",
            "[T]": "76160"
          }
        },
        {
          "id": "2 - Main/441-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to analogue or addressable smoke detector with integral low frequency sounder",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to analogue or addressable smoke detector with integral low frequency sounder",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22758
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,380.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/441-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to addressable optical smoke detector with built-in isolator base with sounder points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to addressable optical smoke detector with built-in isolator base with sounder points",
          "quantity": 3044,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 1034960,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22760
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "99",
            "Tower 1 [E]": "723",
            "Tower 2 [F]": "767",
            "Tower 3 [G]": "734",
            "Tower 4 [H]": "721",
            "TOTAL QTY [I]": "3,044",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,660.00",
            "TOWER 1 [O]": "245,820.00",
            "TOWER 2 [P]": "260,780.00",
            "TOWER 3 [Q]": "249,560.00",
            "TOWER 4 [R]": "245,140.00",
            "[S]": "TRUE",
            "[T]": "-680"
          }
        },
        {
          "id": "2 - Main/441-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to analogue/addressable combined optical/heat detector type c/w base and semi recess kit points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to analogue/addressable combined optical/heat detector type c/w base and semi recess kit points",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22762
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,380.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/441-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to ceiling mounted evacuation speaker with fire rated back box points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to ceiling mounted evacuation speaker with fire rated back box points",
          "quantity": 2839,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 965260,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22764
          },
          "extra_columns": {
            "Basement [C]": "67",
            "GF & Podium [D]": "273",
            "Tower 1 [E]": "562",
            "Tower 2 [F]": "654",
            "Tower 3 [G]": "679",
            "Tower 4 [H]": "604",
            "TOTAL QTY [I]": "2,839",
            "BASEMENTS [M]": "22,780.00",
            "GF & PODIUM [N]": "92,820.00",
            "TOWER 1 [O]": "191,080.00",
            "TOWER 2 [P]": "222,360.00",
            "TOWER 3 [Q]": "230,860.00",
            "TOWER 4 [R]": "205,360.00",
            "[S]": "TRUE",
            "[T]": "14280"
          }
        },
        {
          "id": "2 - Main/441-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to ceiling mounted evacuation speaker with fire dome + strobe points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to ceiling mounted evacuation speaker with fire dome + strobe points",
          "quantity": 1645,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 559300,
          "amount_state": "number",
          "printed_page": "2/R/142",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22766
          },
          "extra_columns": {
            "Basement [C]": "35",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "346",
            "Tower 2 [F]": "385",
            "Tower 3 [G]": "343",
            "Tower 4 [H]": "357",
            "TOTAL QTY [I]": "1,645",
            "BASEMENTS [M]": "11,900.00",
            "GF & PODIUM [N]": "60,860.00",
            "TOWER 1 [O]": "117,640.00",
            "TOWER 2 [P]": "130,900.00",
            "TOWER 3 [Q]": "116,620.00",
            "TOWER 4 [R]": "121,380.00",
            "[S]": "TRUE",
            "[T]": "3740"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/442",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1357280,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/442-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to conventional smoke detector, optical type c/w with base and semi recess kit installed in ceiling void with remote indicator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to conventional smoke detector, optical type c/w with base and semi recess kit installed in ceiling void with remote indicator points",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 5100,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22780
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to elevator fire recall switch points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to elevator fire recall switch points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22782
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to fire alarm ceiling mounted speaker points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to fire alarm ceiling mounted speaker points",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 13260,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22784
          },
          "extra_columns": {
            "Basement [C]": "19",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "6,460.00",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to fire alarm sounder points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to fire alarm sounder points",
          "quantity": 47,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 15980,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22786
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "15",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,400.00",
            "TOWER 2 [P]": "4,080.00",
            "TOWER 3 [Q]": "5,100.00",
            "TOWER 4 [R]": "3,400.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to fire alarm sounder, weatherproof points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to fire alarm sounder, weatherproof points",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 13260,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22788
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "39",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to fire telephone jack points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to fire telephone jack points",
          "quantity": 797,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 270980,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22790
          },
          "extra_columns": {
            "Basement [C]": "46",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "148",
            "Tower 2 [F]": "175",
            "Tower 3 [G]": "168",
            "Tower 4 [H]": "160",
            "TOTAL QTY [I]": "797",
            "BASEMENTS [M]": "15,640.00",
            "GF & PODIUM [N]": "34,000.00",
            "TOWER 1 [O]": "50,320.00",
            "TOWER 2 [P]": "59,500.00",
            "TOWER 3 [Q]": "57,120.00",
            "TOWER 4 [R]": "54,400.00",
            "[S]": "TRUE",
            "[T]": "4080"
          }
        },
        {
          "id": "2 - Main/442-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to FM 200 points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to FM 200 points",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 5440,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22792
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to horn speaker points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to horn speaker points",
          "quantity": 343,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 116620,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22794
          },
          "extra_columns": {
            "Basement [C]": "222",
            "GF & Podium [D]": "121",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "343",
            "BASEMENTS [M]": "75,480.00",
            "GF & PODIUM [N]": "41,140.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to interface unit points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to interface unit points",
          "quantity": 1627,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 553180,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22796
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "338",
            "Tower 2 [F]": "391",
            "Tower 3 [G]": "446",
            "Tower 4 [H]": "363",
            "TOTAL QTY [I]": "1,627",
            "BASEMENTS [M]": "4,760.00",
            "GF & PODIUM [N]": "25,500.00",
            "TOWER 1 [O]": "114,920.00",
            "TOWER 2 [P]": "132,940.00",
            "TOWER 3 [Q]": "151,640.00",
            "TOWER 4 [R]": "123,420.00",
            "[S]": "TRUE",
            "[T]": "8500"
          }
        },
        {
          "id": "2 - Main/442-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to manual call point points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to manual call point points",
          "quantity": 885,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 300900,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22798
          },
          "extra_columns": {
            "Basement [C]": "48",
            "GF & Podium [D]": "174",
            "Tower 1 [E]": "150",
            "Tower 2 [F]": "178",
            "Tower 3 [G]": "174",
            "Tower 4 [H]": "161",
            "TOTAL QTY [I]": "885",
            "BASEMENTS [M]": "16,320.00",
            "GF & PODIUM [N]": "59,160.00",
            "TOWER 1 [O]": "51,000.00",
            "TOWER 2 [P]": "60,520.00",
            "TOWER 3 [Q]": "59,160.00",
            "TOWER 4 [R]": "54,740.00",
            "[S]": "TRUE",
            "[T]": "3740"
          }
        },
        {
          "id": "2 - Main/442-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to manual call point, weatherproof points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to manual call point, weatherproof points",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2040,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22800
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,040.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-M",
          "item_code": "M",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to reset switch\r\n points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to reset switch\r\n points",
          "quantity": 71,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 24140,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22802
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "24,140.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-N",
          "item_code": "N",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to wall mounted speaker points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to wall mounted speaker points",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 9860,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22804
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-P",
          "item_code": "P",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to wall mounted speaker with strobe points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to wall mounted speaker with strobe points",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 9860,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22806
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,480.00",
            "TOWER 1 [O]": "680.00",
            "TOWER 2 [P]": "680.00",
            "TOWER 3 [Q]": "340.00",
            "TOWER 4 [R]": "680.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-Q",
          "item_code": "Q",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From FACP to wall mounted evacuation speaker with fire dome",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From FACP to wall mounted evacuation speaker with fire dome",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 2380,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22809
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,380.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-R",
          "item_code": "R",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to 24x7 panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to 24x7 panel points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22811
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-S",
          "item_code": "S",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to annunciator unit points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to annunciator unit points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22813
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/442-T",
          "item_code": "T",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to auxiliary panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to auxiliary panel points",
          "quantity": 38,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 12920,
          "amount_state": "number",
          "printed_page": "2/R/143",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22815
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,360.00",
            "TOWER 1 [O]": "3,400.00",
            "TOWER 2 [P]": "2,720.00",
            "TOWER 3 [Q]": "2,720.00",
            "TOWER 4 [R]": "2,720.00",
            "[S]": "TRUE",
            "[T]": "-680"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/443",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2508310,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/443-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to emergency voice alarm/alarm communication system unit point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to emergency voice alarm/alarm communication system unit point",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22833
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to fire alarm control panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to fire alarm control panel points",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 7140,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22835
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,700.00",
            "TOWER 1 [O]": "1,360.00",
            "TOWER 2 [P]": "1,020.00",
            "TOWER 3 [Q]": "2,040.00",
            "TOWER 4 [R]": "1,020.00",
            "[S]": "TRUE",
            "[T]": "-340"
          }
        },
        {
          "id": "2 - Main/443-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to power supply unit with batteries points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to power supply unit with batteries points",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 1700,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22837
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to fire detection and alarm system unit points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to fire detection and alarm system unit points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22839
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to fire fighter's control panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to fire fighter's control panel points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22841
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to fire pump status indicator points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to fire pump status indicator points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22843
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to generator supervision devices, manual start and transfer features points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to generator supervision devices, manual start and transfer features points",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 680,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22845
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From graphic workstation to main fire alarm control panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From graphic workstation to main fire alarm control panel points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22847
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to repeater panel with full function points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to repeater panel with full function points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22849
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From MFACP/FACP to sprinkler valve and water flow detector display panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From MFACP/FACP to sprinkler valve and water flow detector display panel points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 340,
          "amount_aed": 340,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22851
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "340.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Abort switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Abort switch",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22855
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/443-M",
          "item_code": "M",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Addressable heat detector with built-in isolator base",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Addressable heat detector with built-in isolator base",
          "quantity": 2392,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 478400,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22857
          },
          "extra_columns": {
            "Basement [C]": "20",
            "GF & Podium [D]": "314",
            "Tower 1 [E]": "492",
            "Tower 2 [F]": "532",
            "Tower 3 [G]": "532",
            "Tower 4 [H]": "502",
            "TOTAL QTY [I]": "2,392",
            "BASEMENTS [M]": "4,000.00",
            "GF & PODIUM [N]": "62,800.00",
            "TOWER 1 [O]": "98,400.00",
            "TOWER 2 [P]": "106,400.00",
            "TOWER 3 [Q]": "106,400.00",
            "TOWER 4 [R]": "100,400.00",
            "[S]": "TRUE",
            "[T]": "2000"
          }
        },
        {
          "id": "2 - Main/443-N",
          "item_code": "N",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Addressable optical smoke detector with built-in isolator base",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Addressable optical smoke detector with built-in isolator base",
          "quantity": 8769,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 2016870,
          "amount_state": "number",
          "printed_page": "2/R/144",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22859
          },
          "extra_columns": {
            "Basement [C]": "107",
            "GF & Podium [D]": "501",
            "Tower 1 [E]": "1,824",
            "Tower 2 [F]": "2,151",
            "Tower 3 [G]": "2,138",
            "Tower 4 [H]": "2,048",
            "TOTAL QTY [I]": "8,769",
            "BASEMENTS [M]": "24,610.00",
            "GF & PODIUM [N]": "115,230.00",
            "TOWER 1 [O]": "419,520.00",
            "TOWER 2 [P]": "494,730.00",
            "TOWER 3 [Q]": "491,740.00",
            "TOWER 4 [R]": "471,040.00",
            "[S]": "TRUE",
            "[T]": "51520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/444",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 700120,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/444-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Addressable optical smoke detector with built-in isolator base with sounder",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Addressable optical smoke detector with built-in isolator base with sounder",
          "quantity": 3044,
          "unit": "Nr.",
          "rate_aed": 230,
          "amount_aed": 700120,
          "amount_state": "number",
          "printed_page": "2/R/145",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22872
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "99",
            "Tower 1 [E]": "723",
            "Tower 2 [F]": "767",
            "Tower 3 [G]": "734",
            "Tower 4 [H]": "721",
            "TOTAL QTY [I]": "3,044",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,770.00",
            "TOWER 1 [O]": "166,290.00",
            "TOWER 2 [P]": "176,410.00",
            "TOWER 3 [Q]": "168,820.00",
            "TOWER 4 [R]": "165,830.00",
            "[S]": "TRUE",
            "[T]": "-460"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/445",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3899580,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/445-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Analogue or addressable smoke detector with integral low frequency sounder",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Analogue or addressable smoke detector with integral low frequency sounder",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 1400,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22919
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,400.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Analogue/addressable combined optical/heat detector type c/w base and semi recess kit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Analogue/addressable combined optical/heat detector type c/w base and semi recess kit",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 1400,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22921
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Ceiling mounted evacuation speaker with fire rated back box",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Ceiling mounted evacuation speaker with fire rated back box",
          "quantity": 2813,
          "unit": "Nr.",
          "rate_aed": 260,
          "amount_aed": 731380,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22923
          },
          "extra_columns": {
            "Basement [C]": "67",
            "GF & Podium [D]": "273",
            "Tower 1 [E]": "562",
            "Tower 2 [F]": "654",
            "Tower 3 [G]": "653",
            "Tower 4 [H]": "604",
            "TOTAL QTY [I]": "2,813",
            "BASEMENTS [M]": "17,420.00",
            "GF & PODIUM [N]": "70,980.00",
            "TOWER 1 [O]": "146,120.00",
            "TOWER 2 [P]": "170,040.00",
            "TOWER 3 [Q]": "169,780.00",
            "TOWER 4 [R]": "157,040.00",
            "[S]": "TRUE",
            "[T]": "10920"
          }
        },
        {
          "id": "2 - Main/445-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Ceiling mounted evacuation speaker with fire dome + strobe",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Ceiling mounted evacuation speaker with fire dome + strobe",
          "quantity": 1657,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 530240,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22925
          },
          "extra_columns": {
            "Basement [C]": "35",
            "GF & Podium [D]": "179",
            "Tower 1 [E]": "346",
            "Tower 2 [F]": "385",
            "Tower 3 [G]": "355",
            "Tower 4 [H]": "357",
            "TOTAL QTY [I]": "1,657",
            "BASEMENTS [M]": "11,200.00",
            "GF & PODIUM [N]": "57,280.00",
            "TOWER 1 [O]": "110,720.00",
            "TOWER 2 [P]": "123,200.00",
            "TOWER 3 [Q]": "113,600.00",
            "TOWER 4 [R]": "114,240.00",
            "[S]": "TRUE",
            "[T]": "3520"
          }
        },
        {
          "id": "2 - Main/445-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Conventional smoke detector, optical type c/w with base and semi recess kit installed in ceiling void with remote indicator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Conventional smoke detector, optical type c/w with base and semi recess kit installed in ceiling void with remote indicator",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 550,
          "amount_aed": 8250,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22927
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Elevator fire recall switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Elevator fire recall switch",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22929
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm ceiling mounted speaker",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fire alarm ceiling mounted speaker",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 13650,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22931
          },
          "extra_columns": {
            "Basement [C]": "19",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "6,650.00",
            "GF & PODIUM [N]": "7,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm sounder",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fire alarm sounder",
          "quantity": 37,
          "unit": "Nr.",
          "rate_aed": 410,
          "amount_aed": 15170,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22933
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "12",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "37",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,100.00",
            "TOWER 2 [P]": "4,920.00",
            "TOWER 3 [Q]": "2,050.00",
            "TOWER 4 [R]": "4,100.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm sounder, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fire alarm sounder, weatherproof",
          "quantity": 39,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 17550,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22935
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "39",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,550.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm sounder and flasher combined unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fire alarm sounder and flasher combined unit",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22937
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "10",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fire telephone jack",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fire telephone jack",
          "quantity": 803,
          "unit": "Nr.",
          "rate_aed": 170,
          "amount_aed": 136510,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22939
          },
          "extra_columns": {
            "Basement [C]": "46",
            "GF & Podium [D]": "100",
            "Tower 1 [E]": "148",
            "Tower 2 [F]": "175",
            "Tower 3 [G]": "174",
            "Tower 4 [H]": "160",
            "TOTAL QTY [I]": "803",
            "BASEMENTS [M]": "7,820.00",
            "GF & PODIUM [N]": "17,000.00",
            "TOWER 1 [O]": "25,160.00",
            "TOWER 2 [P]": "29,750.00",
            "TOWER 3 [Q]": "29,580.00",
            "TOWER 4 [R]": "27,200.00",
            "[S]": "TRUE",
            "[T]": "2040"
          }
        },
        {
          "id": "2 - Main/445-M",
          "item_code": "M",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "FM 200",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — FM 200",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22941
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-N",
          "item_code": "N",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Horn speaker",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Horn speaker",
          "quantity": 343,
          "unit": "Nr.",
          "rate_aed": 410,
          "amount_aed": 140630,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22943
          },
          "extra_columns": {
            "Basement [C]": "222",
            "GF & Podium [D]": "121",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "343",
            "BASEMENTS [M]": "91,020.00",
            "GF & PODIUM [N]": "49,610.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-P",
          "item_code": "P",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Interface unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Interface unit",
          "quantity": 1627,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 1789700,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22945
          },
          "extra_columns": {
            "Basement [C]": "14",
            "GF & Podium [D]": "75",
            "Tower 1 [E]": "338",
            "Tower 2 [F]": "391",
            "Tower 3 [G]": "446",
            "Tower 4 [H]": "363",
            "TOTAL QTY [I]": "1,627",
            "BASEMENTS [M]": "15,400.00",
            "GF & PODIUM [N]": "82,500.00",
            "TOWER 1 [O]": "371,800.00",
            "TOWER 2 [P]": "430,100.00",
            "TOWER 3 [Q]": "490,600.00",
            "TOWER 4 [R]": "399,300.00",
            "[S]": "TRUE",
            "[T]": "27500"
          }
        },
        {
          "id": "2 - Main/445-Q",
          "item_code": "Q",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Manual call point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Manual call point",
          "quantity": 882,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 370440,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22947
          },
          "extra_columns": {
            "Basement [C]": "48",
            "GF & Podium [D]": "174",
            "Tower 1 [E]": "150",
            "Tower 2 [F]": "178",
            "Tower 3 [G]": "171",
            "Tower 4 [H]": "161",
            "TOTAL QTY [I]": "882",
            "BASEMENTS [M]": "20,160.00",
            "GF & PODIUM [N]": "73,080.00",
            "TOWER 1 [O]": "63,000.00",
            "TOWER 2 [P]": "74,760.00",
            "TOWER 3 [Q]": "71,820.00",
            "TOWER 4 [R]": "67,620.00",
            "[S]": "TRUE",
            "[T]": "4620"
          }
        },
        {
          "id": "2 - Main/445-R",
          "item_code": "R",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Manual call point, weatherproof",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Manual call point, weatherproof",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 460,
          "amount_aed": 2760,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22949
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-S",
          "item_code": "S",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Reset switch",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Reset switch",
          "quantity": 71,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 28400,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22951
          },
          "extra_columns": {
            "Basement [C]": "71",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "28,400.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-T",
          "item_code": "T",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted speaker",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted speaker",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 13050,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22953
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "29",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-U",
          "item_code": "U",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted speaker with strobe",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted speaker with strobe",
          "quantity": 29,
          "unit": "Nr.",
          "rate_aed": 450,
          "amount_aed": 13050,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22955
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,900.00",
            "TOWER 1 [O]": "900.00",
            "TOWER 2 [P]": "900.00",
            "TOWER 3 [Q]": "450.00",
            "TOWER 4 [R]": "900.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/445-V",
          "item_code": "V",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted evacuation speaker with fire dome",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted evacuation speaker with fire dome",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/146",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22957
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/446",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1194700,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/446-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "24x7 panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — 24x7 panel",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 13600,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22972
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Annunciator unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Annunciator unit",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22974
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Auxiliary panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Auxiliary panel",
          "quantity": 38,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 258400,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22976
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "10",
            "Tower 2 [F]": "8",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,200.00",
            "TOWER 1 [O]": "68,000.00",
            "TOWER 2 [P]": "54,400.00",
            "TOWER 3 [Q]": "54,400.00",
            "TOWER 4 [R]": "54,400.00",
            "[S]": "TRUE",
            "[T]": "-13600"
          }
        },
        {
          "id": "2 - Main/446-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Emergency voice alarm/alarm communication system unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Emergency voice alarm/alarm communication system unit",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22978
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm control panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire alarm control panel",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 26250,
          "amount_aed": 551250,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22980
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "131,250.00",
            "TOWER 1 [O]": "105,000.00",
            "TOWER 2 [P]": "78,750.00",
            "TOWER 3 [Q]": "157,500.00",
            "TOWER 4 [R]": "78,750.00",
            "[S]": "TRUE",
            "[T]": "-26250"
          }
        },
        {
          "id": "2 - Main/446-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Power supply unit with batteries",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Power supply unit with batteries",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 175000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22982
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "175,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire detection and alarm system unit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire detection and alarm system unit",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 50000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22984
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire fighter's control panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire fighter's control panel",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 13600,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22986
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire pump status indicator",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire pump status indicator",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22988
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Generator supervision devices, manual start and transfer features",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Generator supervision devices, manual start and transfer features",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 40000,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22990
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Main fire alarm control panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Main fire alarm control panel",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 47250,
          "amount_aed": 47250,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22992
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "47,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-M",
          "item_code": "M",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Repeater panel with full function",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Repeater panel with full function",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 6800,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22994
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/446-N",
          "item_code": "N",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Sprinkler valve and water flow detector display panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Sprinkler valve and water flow detector display panel",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6800,
          "amount_aed": 6800,
          "amount_state": "number",
          "printed_page": "2/R/147",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 22996
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/447",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 8339580,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/447-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "To BMS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — To BMS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23011
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/447-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "To access control panel, ACP",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — To access control panel, ACP",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23013
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/447-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "To gas leak detection panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — To gas leak detection panel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23015
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/447-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm installations at Tower 3 Level 29 common areas",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire alarm installations at Tower 3 Level 29 common areas",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23017
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/447-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Fire alarm installations at Tower 4 Level 55 common areas",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Fire alarm interfacing works complete; including cables, conduits, terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Fire alarm installations at Tower 4 Level 55 common areas",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23019
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/447-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Emergency Lighting System",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From central battery main panel to emergency lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Emergency Lighting System — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From central battery main panel to emergency lighting points",
          "quantity": 6891,
          "unit": "Nr.",
          "rate_aed": 355,
          "amount_aed": 2446305,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23025
          },
          "extra_columns": {
            "Basement [C]": "876",
            "GF & Podium [D]": "1,177",
            "Tower 1 [E]": "1,087",
            "Tower 2 [F]": "1,313",
            "Tower 3 [G]": "1,232",
            "Tower 4 [H]": "1,206",
            "TOTAL QTY [I]": "6,891",
            "BASEMENTS [M]": "310,980.00",
            "GF & PODIUM [N]": "417,835.00",
            "TOWER 1 [O]": "385,885.00",
            "TOWER 2 [P]": "466,115.00",
            "TOWER 3 [Q]": "437,360.00",
            "TOWER 4 [R]": "428,130.00",
            "[S]": "TRUE",
            "[T]": "42245"
          }
        },
        {
          "id": "2 - Main/447-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Emergency Lighting System",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From central battery main panel to exit lighting points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Emergency Lighting System — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From central battery main panel to exit lighting points",
          "quantity": 2898,
          "unit": "Nr.",
          "rate_aed": 355,
          "amount_aed": 1028790,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23027
          },
          "extra_columns": {
            "Basement [C]": "237",
            "GF & Podium [D]": "529",
            "Tower 1 [E]": "489",
            "Tower 2 [F]": "561",
            "Tower 3 [G]": "565",
            "Tower 4 [H]": "517",
            "TOTAL QTY [I]": "2,898",
            "BASEMENTS [M]": "84,135.00",
            "GF & PODIUM [N]": "187,795.00",
            "TOWER 1 [O]": "173,595.00",
            "TOWER 2 [P]": "199,155.00",
            "TOWER 3 [Q]": "200,575.00",
            "TOWER 4 [R]": "183,535.00",
            "[S]": "TRUE",
            "[T]": "9940"
          }
        },
        {
          "id": "2 - Main/447-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Emergency Lighting System",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From central battery main panel to sub CBU panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Emergency Lighting System — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From central battery main panel to sub CBU panel",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 355,
          "amount_aed": 5325,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23029
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,420.00",
            "TOWER 2 [P]": "1,420.00",
            "TOWER 3 [Q]": "1,420.00",
            "TOWER 4 [R]": "1,065.00",
            "[S]": "TRUE",
            "[T]": "-355"
          }
        },
        {
          "id": "2 - Main/447-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Emergency Lighting System",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From central battery main panel to working station at GF-FCC room",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Emergency Lighting System — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From central battery main panel to working station at GF-FCC room",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 355,
          "amount_aed": 2840,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23031
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,840.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/447-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Type E1; 8 x 1W LED, ceiling/wall surface mounted bulkhead type downlight, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Type E1; 8 x 1W LED, ceiling/wall surface mounted bulkhead type downlight, IP65",
          "quantity": 3560,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 2705600,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23035
          },
          "extra_columns": {
            "Basement [C]": "795",
            "GF & Podium [D]": "738",
            "Tower 1 [E]": "437",
            "Tower 2 [F]": "558",
            "Tower 3 [G]": "525",
            "Tower 4 [H]": "507",
            "TOTAL QTY [I]": "3,560",
            "BASEMENTS [M]": "604,200.00",
            "GF & PODIUM [N]": "560,880.00",
            "TOWER 1 [O]": "332,120.00",
            "TOWER 2 [P]": "424,080.00",
            "TOWER 3 [Q]": "399,000.00",
            "TOWER 4 [R]": "385,320.00",
            "[S]": "TRUE",
            "[T]": "53200"
          }
        },
        {
          "id": "2 - Main/447-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Type E6; 4 x 1W LED, ceiling recess mounted emergency luminaire with stainless steel brushed/powder coated, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Type E6; 4 x 1W LED, ceiling recess mounted emergency luminaire with stainless steel brushed/powder coated, IP20",
          "quantity": 2797,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 2125720,
          "amount_state": "number",
          "printed_page": "2/R/148",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23037
          },
          "extra_columns": {
            "Basement [C]": "61",
            "GF & Podium [D]": "323",
            "Tower 1 [E]": "553",
            "Tower 2 [F]": "643",
            "Tower 3 [G]": "622",
            "Tower 4 [H]": "595",
            "TOTAL QTY [I]": "2,797",
            "BASEMENTS [M]": "46,360.00",
            "GF & PODIUM [N]": "245,480.00",
            "TOWER 1 [O]": "420,280.00",
            "TOWER 2 [P]": "488,680.00",
            "TOWER 3 [Q]": "472,720.00",
            "TOWER 4 [R]": "452,200.00",
            "[S]": "TRUE",
            "[T]": "31920"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/448",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1972960,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/448-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Type E7; 4 x 1W LED, 405 lm ceiling recessed luminaire with stainless steel brushed/powder coated, IP20",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Type E7; 4 x 1W LED, 405 lm ceiling recessed luminaire with stainless steel brushed/powder coated, IP20",
          "quantity": 520,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 395200,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23049
          },
          "extra_columns": {
            "Basement [C]": "20",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "97",
            "Tower 2 [F]": "112",
            "Tower 3 [G]": "110",
            "Tower 4 [H]": "104",
            "TOTAL QTY [I]": "520",
            "BASEMENTS [M]": "15,200.00",
            "GF & PODIUM [N]": "58,520.00",
            "TOWER 1 [O]": "73,720.00",
            "TOWER 2 [P]": "85,120.00",
            "TOWER 3 [Q]": "83,600.00",
            "TOWER 4 [R]": "79,040.00",
            "[S]": "TRUE",
            "[T]": "5320"
          }
        },
        {
          "id": "2 - Main/448-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Type E8; 4 x 1W, 338 lm wall or ceiling mounted, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Type E8; 4 x 1W, 338 lm wall or ceiling mounted, IP65",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 24320,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23051
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "23",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "6,840.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Type E10; 8W LED,self contained emergency luminaire with 3hrs battery pack, IP65",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Type E10; 8W LED,self contained emergency luminaire with 3hrs battery pack, IP65",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 12160,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23053
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "1.8W LED, ceiling recessed edge lit aluminum profile LED exit light, IP20 (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 1.8W LED, ceiling recessed edge lit aluminum profile LED exit light, IP20 (FOH)",
          "quantity": 432,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 328320,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23055
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "27",
            "Tower 1 [E]": "92",
            "Tower 2 [F]": "108",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "100",
            "TOTAL QTY [I]": "432",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,520.00",
            "TOWER 1 [O]": "69,920.00",
            "TOWER 2 [P]": "82,080.00",
            "TOWER 3 [Q]": "79,800.00",
            "TOWER 4 [R]": "76,000.00",
            "[S]": "TRUE",
            "[T]": "6080"
          }
        },
        {
          "id": "2 - Main/448-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "1.8W LED, ceiling recessed edge lit aluminum profile S LED exit light, IP20 (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 1.8W LED, ceiling recessed edge lit aluminum profile S LED exit light, IP20 (FOH)",
          "quantity": 445,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 338200,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23057
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "37",
            "Tower 1 [E]": "93",
            "Tower 2 [F]": "109",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "101",
            "TOTAL QTY [I]": "445",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,120.00",
            "TOWER 1 [O]": "70,680.00",
            "TOWER 2 [P]": "82,840.00",
            "TOWER 3 [Q]": "79,800.00",
            "TOWER 4 [R]": "76,760.00",
            "[S]": "TRUE",
            "[T]": "6080"
          }
        },
        {
          "id": "2 - Main/448-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "2W LED, 500cd/sqm double sided emergency exit, IP65 (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 2W LED, 500cd/sqm double sided emergency exit, IP65 (FOH)",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 19000,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23059
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "25",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4W LED, 500cd/sqm double sided emergency exit, IP65 (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4W LED, 500cd/sqm double sided emergency exit, IP65 (FOH)",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 15200,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23061
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4W LED, 510 lm wall or ceiling mounted explosion proof, emergency exit luminaire, IP66",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4W LED, 510 lm wall or ceiling mounted explosion proof, emergency exit luminaire, IP66",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 760,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23063
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 11400,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23065
          },
          "extra_columns": {
            "Basement [C]": "1",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "760.00",
            "GF & PODIUM [N]": "9,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4 x 1W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4 x 1W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "quantity": 45,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 34200,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23067
          },
          "extra_columns": {
            "Basement [C]": "15",
            "GF & Podium [D]": "21",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "45",
            "BASEMENTS [M]": "11,400.00",
            "GF & PODIUM [N]": "15,960.00",
            "TOWER 1 [O]": "1,520.00",
            "TOWER 2 [P]": "760.00",
            "TOWER 3 [Q]": "3,040.00",
            "TOWER 4 [R]": "1,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4 x 1W LED,  wall/ceiling mounted emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4 x 1W LED,  wall/ceiling mounted emergency directional exit signage, IP65 (BOH)",
          "quantity": 263,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 199880,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23069
          },
          "extra_columns": {
            "Basement [C]": "132",
            "GF & Podium [D]": "106",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "15",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "263",
            "BASEMENTS [M]": "100,320.00",
            "GF & PODIUM [N]": "80,560.00",
            "TOWER 1 [O]": "4,560.00",
            "TOWER 2 [P]": "2,280.00",
            "TOWER 3 [Q]": "11,400.00",
            "TOWER 4 [R]": "760.00",
            "[S]": "TRUE",
            "[T]": "-3800"
          }
        },
        {
          "id": "2 - Main/448-M",
          "item_code": "M",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4 x 1W LED, wall/ceiling mounted exit light, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4 x 1W LED, wall/ceiling mounted exit light, IP65 (BOH)",
          "quantity": 84,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 63840,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23071
          },
          "extra_columns": {
            "Basement [C]": "29",
            "GF & Podium [D]": "55",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "22,040.00",
            "GF & PODIUM [N]": "41,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-N",
          "item_code": "N",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Ceiling recessed edge lit aluminum profile LED exit light (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Ceiling recessed edge lit aluminum profile LED exit light (FOH)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 760,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23073
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/448-P",
          "item_code": "P",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted LED exit light, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted LED exit light, IP65 (BOH)",
          "quantity": 697,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 529720,
          "amount_state": "number",
          "printed_page": "2/R/149",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23075
          },
          "extra_columns": {
            "Basement [C]": "44",
            "GF & Podium [D]": "135",
            "Tower 1 [E]": "109",
            "Tower 2 [F]": "123",
            "Tower 3 [G]": "175",
            "Tower 4 [H]": "111",
            "TOTAL QTY [I]": "697",
            "BASEMENTS [M]": "33,440.00",
            "GF & PODIUM [N]": "102,600.00",
            "TOWER 1 [O]": "82,840.00",
            "TOWER 2 [P]": "93,480.00",
            "TOWER 3 [Q]": "133,000.00",
            "TOWER 4 [R]": "84,360.00",
            "[S]": "TRUE",
            "[T]": "1520"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/449",
      "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1851980,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/449-A",
          "item_code": "A",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted edge lit aluminum profile LED exit light, IP20 (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted edge lit aluminum profile LED exit light, IP20 (FOH)",
          "quantity": 833,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 633080,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23090
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "57",
            "Tower 1 [E]": "187",
            "Tower 2 [F]": "217",
            "Tower 3 [G]": "154",
            "Tower 4 [H]": "202",
            "TOTAL QTY [I]": "833",
            "BASEMENTS [M]": "12,160.00",
            "GF & PODIUM [N]": "43,320.00",
            "TOWER 1 [O]": "142,120.00",
            "TOWER 2 [P]": "164,920.00",
            "TOWER 3 [Q]": "117,040.00",
            "TOWER 4 [R]": "153,520.00",
            "[S]": "TRUE",
            "[T]": "11400"
          }
        },
        {
          "id": "2 - Main/449-B",
          "item_code": "B",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted/ceiling recessed edge lit LED exit light with LED (FOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted/ceiling recessed edge lit LED exit light with LED (FOH)",
          "quantity": 31,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 23560,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23092
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "31",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "23,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/449-C",
          "item_code": "C",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4 x 1W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4 x 1W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 760,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23094
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "760.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/449-D",
          "item_code": "D",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4 x 1W LED,  wall/ceiling mounted emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4 x 1W LED,  wall/ceiling mounted emergency directional exit signage, IP65 (BOH)",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 4560,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23096
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "4,560.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/449-E",
          "item_code": "E",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "4W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 4W LED,  ceiling mounted/ceiling suspended emergency directional exit signage, IP65 (BOH)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 760,
          "amount_aed": 1520,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23098
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "1,520.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/449-F",
          "item_code": "F",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Emergency lighting installations at Tower 3 Level 29 common areas",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Emergency lighting installations at Tower 3 Level 29 common areas",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 10000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23100
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/449-G",
          "item_code": "G",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Emergency lighting installations at Tower 4 Level 55 common areas",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Emergency lighting installations at Tower 4 Level 55 common areas",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 10000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23102
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/449-H",
          "item_code": "H",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Central battery main panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Central battery main panel",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 84000,
          "amount_aed": 672000,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23106
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "672,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/449-J",
          "item_code": "J",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Central battery sub-panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming of fully operative system, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Central battery sub-panel",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 31000,
          "amount_aed": 465000,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23108
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "124,000.00",
            "TOWER 2 [P]": "124,000.00",
            "TOWER 3 [Q]": "124,000.00",
            "TOWER 4 [R]": "93,000.00",
            "[S]": "TRUE",
            "[T]": "-31000"
          }
        },
        {
          "id": "2 - Main/449-K",
          "item_code": "K",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "Graphic workstation with touch screen at Tower 4 FCC room",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — Graphic workstation with touch screen at Tower 4 FCC room",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23112
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/449-L",
          "item_code": "L",
          "section": "FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "Master PC at Security room",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — FIRE ALARM AND EMERGENCY LIGHTING INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — Master PC at Security room",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/150",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23114
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/450",
      "section": "COMMUNICATION INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3708395,
      "section_notes": [
        "Note: Refer to the following",
        "1. ICT & AV Drawing Nr. ZD-3250587-EMR-DWG-PDM-ICT-0000 to 1025, TW1-ICT-1105 to 1135, TW2-ICT-1205 to 1250, TW3-ICT-1305 to 1335, TW4-ICT-1405 to 1440; all inclusive",
        "2. Structured Cabling System Specifications; 27 21 100",
        "3. AV-BGM / Digital System Specification; 27 41 00",
        "4. Converged Network System Specification; 27 20 00",
        "5. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/450-A",
          "item_code": "A",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 x 144 + 1 x 48 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 1 x 144 + 1 x 48 core single mode fiber cable",
          "quantity": 247,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 49400,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23152
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "247",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "247",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "49,400.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-49400"
          }
        },
        {
          "id": "2 - Main/450-B",
          "item_code": "B",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 x 144 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 1 x 144 core single mode fiber cable",
          "quantity": 18501,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 2775150,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23154
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "2,032",
            "Tower 2 [F]": "7,597",
            "Tower 3 [G]": "3,775",
            "Tower 4 [H]": "5,097",
            "TOTAL QTY [I]": "18,501",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "304,800.00",
            "TOWER 2 [P]": "1,139,550.00",
            "TOWER 3 [Q]": "566,250.00",
            "TOWER 4 [R]": "764,550.00",
            "[S]": "TRUE",
            "[T]": "459750"
          }
        },
        {
          "id": "2 - Main/450-C",
          "item_code": "C",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 x 96 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 1 x 96 core single mode fiber cable",
          "quantity": 3914,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 234840,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23156
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "989",
            "Tower 1 [E]": "173",
            "Tower 2 [F]": "1,184",
            "Tower 3 [G]": "742",
            "Tower 4 [H]": "826",
            "TOTAL QTY [I]": "3,914",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "59,340.00",
            "TOWER 1 [O]": "10,380.00",
            "TOWER 2 [P]": "71,040.00",
            "TOWER 3 [Q]": "44,520.00",
            "TOWER 4 [R]": "49,560.00",
            "[S]": "TRUE",
            "[T]": "39180"
          }
        },
        {
          "id": "2 - Main/450-D",
          "item_code": "D",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "1 x 48 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 1 x 48 core single mode fiber cable",
          "quantity": 1765,
          "unit": "m",
          "rate_aed": 25,
          "amount_aed": 44125,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23158
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "1,299",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "466",
            "TOTAL QTY [I]": "1,765",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "32,475.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "11,650.00",
            "[S]": "TRUE",
            "[T]": "11650"
          }
        },
        {
          "id": "2 - Main/450-E",
          "item_code": "E",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "2 x 6 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2 x 6 core single mode fiber cable",
          "quantity": 240,
          "unit": "m",
          "rate_aed": 15,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23160
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "240",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "240",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/450-F",
          "item_code": "F",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "4 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 4 core single mode fiber cable",
          "quantity": 70688,
          "unit": "m",
          "rate_aed": 5,
          "amount_aed": 353440,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23162
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5,194",
            "Tower 1 [E]": "15,257",
            "Tower 2 [F]": "16,435",
            "Tower 3 [G]": "17,467",
            "Tower 4 [H]": "16,335",
            "TOTAL QTY [I]": "70,688",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,970.00",
            "TOWER 1 [O]": "76,285.00",
            "TOWER 2 [P]": "82,175.00",
            "TOWER 3 [Q]": "87,335.00",
            "TOWER 4 [R]": "81,675.00",
            "[S]": "TRUE",
            "[T]": "5390"
          }
        },
        {
          "id": "2 - Main/450-G",
          "item_code": "G",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "24 core single mode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 24 core single mode fiber cable",
          "quantity": 7441,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 148820,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23164
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "192",
            "Tower 1 [E]": "824",
            "Tower 2 [F]": "3,362",
            "Tower 3 [G]": "1,237",
            "Tower 4 [H]": "1,826",
            "TOTAL QTY [I]": "7,441",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,840.00",
            "TOWER 1 [O]": "16,480.00",
            "TOWER 2 [P]": "67,240.00",
            "TOWER 3 [Q]": "24,740.00",
            "TOWER 4 [R]": "36,520.00",
            "[S]": "TRUE",
            "[T]": "20040"
          }
        },
        {
          "id": "2 - Main/450-H",
          "item_code": "H",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "ICT Installation",
            "Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary"
          ],
          "own_description": "2 x 6 core multimode fiber cable",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — ICT Installation — Fiber optic cables; including fixings, supports, terminations, accessories and all ancillary works as necessary — 2 x 6 core multimode fiber cable",
          "quantity": 4951,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 99020,
          "amount_state": "number",
          "printed_page": "2/R/151",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23166
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1,933",
            "Tower 1 [E]": "839",
            "Tower 2 [F]": "902",
            "Tower 3 [G]": "742",
            "Tower 4 [H]": "535",
            "TOTAL QTY [I]": "4,951",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "38,660.00",
            "TOWER 1 [O]": "16,780.00",
            "TOWER 2 [P]": "18,040.00",
            "TOWER 3 [Q]": "14,840.00",
            "TOWER 4 [R]": "10,700.00",
            "[S]": "TRUE",
            "[T]": "-6080"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/451",
      "section": "COMMUNICATION INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 6899321,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/451-A",
          "item_code": "A",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "50mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 50mm wide cable tray",
          "quantity": 77,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 4620,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23187
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "77",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,620.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/451-B",
          "item_code": "B",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "100mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 100mm wide cable tray",
          "quantity": 1059,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 79425,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23189
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "546",
            "Tower 1 [E]": "65",
            "Tower 2 [F]": "295",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "150",
            "TOTAL QTY [I]": "1,059",
            "BASEMENTS [M]": "225.00",
            "GF & PODIUM [N]": "40,950.00",
            "TOWER 1 [O]": "4,875.00",
            "TOWER 2 [P]": "22,125.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "11,250.00",
            "[S]": "TRUE",
            "[T]": "6375"
          }
        },
        {
          "id": "2 - Main/451-C",
          "item_code": "C",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "150mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 150mm wide cable tray",
          "quantity": 18181,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 1454480,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23191
          },
          "extra_columns": {
            "Basement [C]": "3,711",
            "GF & Podium [D]": "3,497",
            "Tower 1 [E]": "2,536",
            "Tower 2 [F]": "2,900",
            "Tower 3 [G]": "2,819",
            "Tower 4 [H]": "2,718",
            "TOTAL QTY [I]": "18,181",
            "BASEMENTS [M]": "296,880.00",
            "GF & PODIUM [N]": "279,760.00",
            "TOWER 1 [O]": "202,880.00",
            "TOWER 2 [P]": "232,000.00",
            "TOWER 3 [Q]": "225,520.00",
            "TOWER 4 [R]": "217,440.00",
            "[S]": "TRUE",
            "[T]": "14560"
          }
        },
        {
          "id": "2 - Main/451-D",
          "item_code": "D",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "200mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 200mm wide cable tray",
          "quantity": 11765,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 1411800,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23193
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "575",
            "Tower 1 [E]": "2,735",
            "Tower 2 [F]": "2,694",
            "Tower 3 [G]": "2,992",
            "Tower 4 [H]": "2,753",
            "TOTAL QTY [I]": "11,765",
            "BASEMENTS [M]": "1,920.00",
            "GF & PODIUM [N]": "69,000.00",
            "TOWER 1 [O]": "328,200.00",
            "TOWER 2 [P]": "323,280.00",
            "TOWER 3 [Q]": "359,040.00",
            "TOWER 4 [R]": "330,360.00",
            "[S]": "TRUE",
            "[T]": "2160"
          }
        },
        {
          "id": "2 - Main/451-E",
          "item_code": "E",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "300mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 300mm wide cable tray",
          "quantity": 2080,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 270400,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23195
          },
          "extra_columns": {
            "Basement [C]": "1,170",
            "GF & Podium [D]": "136",
            "Tower 1 [E]": "172",
            "Tower 2 [F]": "206",
            "Tower 3 [G]": "208",
            "Tower 4 [H]": "188",
            "TOTAL QTY [I]": "2,080",
            "BASEMENTS [M]": "152,100.00",
            "GF & PODIUM [N]": "17,680.00",
            "TOWER 1 [O]": "22,360.00",
            "TOWER 2 [P]": "26,780.00",
            "TOWER 3 [Q]": "27,040.00",
            "TOWER 4 [R]": "24,440.00",
            "[S]": "TRUE",
            "[T]": "2080"
          }
        },
        {
          "id": "2 - Main/451-F",
          "item_code": "F",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "450mm wide cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 450mm wide cable tray",
          "quantity": 849,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 152820,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23197
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "74",
            "Tower 1 [E]": "172",
            "Tower 2 [F]": "206",
            "Tower 3 [G]": "193",
            "Tower 4 [H]": "188",
            "TOTAL QTY [I]": "849",
            "BASEMENTS [M]": "2,880.00",
            "GF & PODIUM [N]": "13,320.00",
            "TOWER 1 [O]": "30,960.00",
            "TOWER 2 [P]": "37,080.00",
            "TOWER 3 [Q]": "34,740.00",
            "TOWER 4 [R]": "33,840.00",
            "[S]": "TRUE",
            "[T]": "2880"
          }
        },
        {
          "id": "2 - Main/451-G",
          "item_code": "G",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "PVC conduit"
          ],
          "own_description": "32mm diameter conduit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — PVC conduit — 32mm diameter conduit",
          "quantity": 194,
          "unit": "m",
          "rate_aed": 14,
          "amount_aed": 2716,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23201
          },
          "extra_columns": {
            "Basement [C]": "159",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "194",
            "BASEMENTS [M]": "2,226.00",
            "GF & PODIUM [N]": "490.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/451-H",
          "item_code": "H",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "PVC conduit"
          ],
          "own_description": "50mm diameter PVC conduit",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — PVC conduit — 50mm diameter PVC conduit",
          "quantity": 18143,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 362860,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23203
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "493",
            "Tower 1 [E]": "4,214",
            "Tower 2 [F]": "4,449",
            "Tower 3 [G]": "4,667",
            "Tower 4 [H]": "4,320",
            "TOTAL QTY [I]": "18,143",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,860.00",
            "TOWER 1 [O]": "84,280.00",
            "TOWER 2 [P]": "88,980.00",
            "TOWER 3 [Q]": "93,340.00",
            "TOWER 4 [R]": "86,400.00",
            "[S]": "TRUE",
            "[T]": "2120"
          }
        },
        {
          "id": "2 - Main/451-J",
          "item_code": "J",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ODF/ICT rack to wall mounted dual data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ODF/ICT rack to wall mounted dual data RJ45 outlet",
          "quantity": 6825,
          "unit": "Nr.",
          "rate_aed": 460,
          "amount_aed": 3139500,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23207
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "257",
            "Tower 1 [E]": "1,543",
            "Tower 2 [F]": "1,673",
            "Tower 3 [G]": "1,744",
            "Tower 4 [H]": "1,608",
            "TOTAL QTY [I]": "6,825",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "118,220.00",
            "TOWER 1 [O]": "709,780.00",
            "TOWER 2 [P]": "769,580.00",
            "TOWER 3 [Q]": "802,240.00",
            "TOWER 4 [R]": "739,680.00",
            "[S]": "TRUE",
            "[T]": "29900"
          }
        },
        {
          "id": "2 - Main/451-K",
          "item_code": "K",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ICT rack to wall mounted dual RJ45 outlet for TV",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ICT rack to wall mounted dual RJ45 outlet for TV",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 5100,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23209
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/451-L",
          "item_code": "L",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ICT rack to wall mounted single data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ICT rack to wall mounted single data RJ45 outlet",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 7200,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23211
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "1,800.00",
            "TOWER 2 [P]": "1,800.00",
            "TOWER 3 [Q]": "1,800.00",
            "TOWER 4 [R]": "1,800.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/451-M",
          "item_code": "M",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ICT rack to floor mounted dual data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ICT rack to floor mounted dual data RJ45 outlet",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23213
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/451-N",
          "item_code": "N",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ICT rack to wireless access point (WAP) single RJ45 outlet (indoor)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ICT rack to wireless access point (WAP) single RJ45 outlet (indoor)",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "2/R/152",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23215
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/452",
      "section": "COMMUNICATION INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 2309365,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/452-A",
          "item_code": "A",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From ICT rack to telephone junction box",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From ICT rack to telephone junction box",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23228
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-B",
          "item_code": "B",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted dual data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted dual data RJ45 outlet",
          "quantity": 6825,
          "unit": "Nr.",
          "rate_aed": 105,
          "amount_aed": 716625,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23232
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "257",
            "Tower 1 [E]": "1,543",
            "Tower 2 [F]": "1,673",
            "Tower 3 [G]": "1,744",
            "Tower 4 [H]": "1,608",
            "TOTAL QTY [I]": "6,825",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,985.00",
            "TOWER 1 [O]": "162,015.00",
            "TOWER 2 [P]": "175,665.00",
            "TOWER 3 [Q]": "183,120.00",
            "TOWER 4 [R]": "168,840.00",
            "[S]": "TRUE",
            "[T]": "6825"
          }
        },
        {
          "id": "2 - Main/452-C",
          "item_code": "C",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted dual RJ45 outlet for TV",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted dual RJ45 outlet for TV",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 110,
          "amount_aed": 1870,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23234
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "17",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,870.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-D",
          "item_code": "D",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted single data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted single data RJ45 outlet",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 60,
          "amount_aed": 1440,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23236
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "24",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "360.00",
            "TOWER 2 [P]": "360.00",
            "TOWER 3 [Q]": "360.00",
            "TOWER 4 [R]": "360.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-E",
          "item_code": "E",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Floor mounted dual data RJ45 outlet",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Floor mounted dual data RJ45 outlet",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 160,
          "amount_aed": 1280,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23238
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-F",
          "item_code": "F",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wireless access point (WAP) single RJ45 outlet (indoor)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wireless access point (WAP) single RJ45 outlet (indoor)",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 1300,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23240
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-G",
          "item_code": "G",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Telephone junction box",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Telephone junction box",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 150,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23242
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-H",
          "item_code": "H",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "47U, ISP rack, 900 x 450mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 47U, ISP rack, 900 x 450mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 47250,
          "amount_aed": 567000,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23246
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "567,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-J",
          "item_code": "J",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "42U, main ICT rack, 800 x 1000mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 42U, main ICT rack, 800 x 1000mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 105000,
          "amount_aed": 105000,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23248
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "105,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-K",
          "item_code": "K",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "27U, AV/ICT cabinet, 600 x 1300 x 600mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 27U, AV/ICT cabinet, 600 x 1300 x 600mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 22500,
          "amount_aed": 112500,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23250
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "112,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-L",
          "item_code": "L",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "15U, ICT cabinet, 750 x 600 x 600mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 15U, ICT cabinet, 750 x 600 x 600mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 17000,
          "amount_aed": 204000,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23252
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "68,000.00",
            "TOWER 1 [O]": "34,000.00",
            "TOWER 2 [P]": "34,000.00",
            "TOWER 3 [Q]": "34,000.00",
            "TOWER 4 [R]": "34,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-M",
          "item_code": "M",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "15U, cross connect cabinet, 600 x 750 x 300mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 15U, cross connect cabinet, 600 x 750 x 300mm",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 105000,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23254
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "5",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "25,000.00",
            "TOWER 2 [P]": "30,000.00",
            "TOWER 3 [Q]": "25,000.00",
            "TOWER 4 [R]": "25,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-N",
          "item_code": "N",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "12U, retail consolidation cabinet, 600 x 600 x 350mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 12U, retail consolidation cabinet, 600 x 600 x 350mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 15750,
          "amount_aed": 110250,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23256
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "110,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/452-P",
          "item_code": "P",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "12U, home consolidation cabinet, 600 x 600 x 150mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — 12U, home consolidation cabinet, 600 x 600 x 150mm",
          "quantity": 267,
          "unit": "Nr.",
          "rate_aed": 1400,
          "amount_aed": 373800,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23258
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "47",
            "Tower 2 [F]": "55",
            "Tower 3 [G]": "53",
            "Tower 4 [H]": "51",
            "TOTAL QTY [I]": "267",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "85,400.00",
            "TOWER 1 [O]": "65,800.00",
            "TOWER 2 [P]": "77,000.00",
            "TOWER 3 [Q]": "74,200.00",
            "TOWER 4 [R]": "71,400.00",
            "[S]": "TRUE",
            "[T]": "5600"
          }
        },
        {
          "id": "2 - Main/452-Q",
          "item_code": "Q",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Cross connect cabinet, 600 x 600 x 300mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — Cross connect cabinet, 600 x 600 x 300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 4200,
          "amount_aed": 8400,
          "amount_state": "number",
          "printed_page": "2/R/153",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23260
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "2",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/453",
      "section": "COMMUNICATION INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 962520,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/453-A",
          "item_code": "A",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted mini ODF, 600 x 600 x 300mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, fixings, supports, hangers, accessories and all ancillary works as necessary — Wall mounted mini ODF, 600 x 600 x 300mm",
          "quantity": 71,
          "unit": "Nr.",
          "rate_aed": 6300,
          "amount_aed": 447300,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23278
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "15",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "17",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "71",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,200.00",
            "TOWER 1 [O]": "94,500.00",
            "TOWER 2 [P]": "113,400.00",
            "TOWER 3 [Q]": "107,100.00",
            "TOWER 4 [R]": "107,100.00",
            "[S]": "TRUE",
            "[T]": "12600"
          }
        },
        {
          "id": "2 - Main/453-B",
          "item_code": "B",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to 65\" UHD TV points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to 65\" UHD TV points",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 3360,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23284
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-C",
          "item_code": "C",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to 55\" UHD TV points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to 55\" UHD TV points",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 3780,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23286
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-D",
          "item_code": "D",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to 15'' digital signage display points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to 15'' digital signage display points",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 11760,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23288
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-E",
          "item_code": "E",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack  to 7\" touch control panel with 4-zone volume & source points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack  to 7\" touch control panel with 4-zone volume & source points",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 5460,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23290
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-F",
          "item_code": "F",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to wall-mounted bluetooth, line in line out, TRS jack & power points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to wall-mounted bluetooth, line in line out, TRS jack & power points",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 5460,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23292
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,460.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-G",
          "item_code": "G",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to 6\" ceiling mounted speaker points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to 6\" ceiling mounted speaker points",
          "quantity": 94,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 39480,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23294
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "94",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-H",
          "item_code": "H",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to media hub with 2 universal power, 1 HDMI, 1 USB-C & 1 USB-A charging points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to media hub with 2 universal power, 1 HDMI, 1 USB-C & 1 USB-A charging points",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 1260,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23296
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-J",
          "item_code": "J",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to 8\" ceiling mounted subwoofer points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to 8\" ceiling mounted subwoofer points",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 6720,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23298
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-K",
          "item_code": "K",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "AV System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From AV/ICT rack to wall mounted speaker points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — AV System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From AV/ICT rack to wall mounted speaker points",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 420,
          "amount_aed": 2940,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23300
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-L",
          "item_code": "L",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "65\" UHD TV",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 65\" UHD TV",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 160000,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23304
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "160,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-M",
          "item_code": "M",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "55\" UHD TV",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 55\" UHD TV",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 135000,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23306
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "135,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/453-N",
          "item_code": "N",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "15'' digital signage display",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 15'' digital signage display",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 140000,
          "amount_state": "number",
          "printed_page": "2/R/154",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23308
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "140,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/454",
      "section": "COMMUNICATION INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 240115,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/454-A",
          "item_code": "A",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "7\" touch control panel with 4-zone volume & source",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 7\" touch control panel with 4-zone volume & source",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 7000,
          "amount_aed": 91000,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23320
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "91,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/454-B",
          "item_code": "B",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall-mounted bluetooth, line in line out, TRS jack & power",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall-mounted bluetooth, line in line out, TRS jack & power",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 685,
          "amount_aed": 8905,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23322
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "13",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,905.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/454-C",
          "item_code": "C",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "6\" ceiling mounted speaker, ref T1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 6\" ceiling mounted speaker, ref T1",
          "quantity": 94,
          "unit": "Nr.",
          "rate_aed": 1050,
          "amount_aed": 98700,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23324
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "94",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "98,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/454-D",
          "item_code": "D",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Media hub with 2 universal power, 1 HDMI, 1 USB-C & 1 USB-A charging",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Media hub with 2 universal power, 1 HDMI, 1 USB-C & 1 USB-A charging",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 5250,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23326
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/454-E",
          "item_code": "E",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "8\" ceiling mounted subwoofer, ref SUB",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — 8\" ceiling mounted subwoofer, ref SUB",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 20160,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23328
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "16",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "20,160.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/454-F",
          "item_code": "F",
          "section": "COMMUNICATION INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Wall mounted speaker, ref T3",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — COMMUNICATION INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Wall mounted speaker, ref T3",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "2/R/155",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23330
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/455",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1211115,
      "section_notes": [
        "Note: Refer to the following",
        "1. Security Drawing Nr. ZD-3250587-CKR-DWG-PDM-SEC-5000 to 5996, 6000 to 6996, 7000 to 7996 TW1-SEC-5040 to 5520, 6040 to 6520, 7040 to 7500, TW2-SEC-5040 to 5600, 6040 to 6600, TW3-SEC-5040 to 5560, 6040 to 6560, 7040 to 7560, TW4-SEC-5040 to 5560, 6040 to 6560, 7040 to 7560; all inclusive",
        "2. Video Surveillance Specifications; 28 23 00",
        "3. Access Control Specifications; 28 13 00",
        "4. Audio Intercom System Specifications; 28 17 00",
        "5. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/455-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "CCTV Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From security rack to camera points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — CCTV Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From security rack to camera points",
          "quantity": 2008,
          "unit": "Nr.",
          "rate_aed": 480,
          "amount_aed": 963840,
          "amount_state": "number",
          "printed_page": "2/R/156",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23384
          },
          "extra_columns": {
            "Basement [C]": "181",
            "GF & Podium [D]": "379",
            "Tower 1 [E]": "331",
            "Tower 2 [F]": "387",
            "Tower 3 [G]": "374",
            "Tower 4 [H]": "356",
            "TOTAL QTY [I]": "2,008",
            "BASEMENTS [M]": "86,880.00",
            "GF & PODIUM [N]": "181,920.00",
            "TOWER 1 [O]": "158,880.00",
            "TOWER 2 [P]": "185,760.00",
            "TOWER 3 [Q]": "179,520.00",
            "TOWER 4 [R]": "170,880.00",
            "[S]": "TRUE",
            "[T]": "12000"
          }
        },
        {
          "id": "2 - Main/455-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "CCTV Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From security control room to equipment room security rack points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — CCTV Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From security control room to equipment room security rack points",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/R/156",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23386
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/455-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "CCTV Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From equipment room security rack to IDF room security rack points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — CCTV Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From equipment room security rack to IDF room security rack points",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 47250,
          "amount_state": "number",
          "printed_page": "2/R/156",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23388
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "7",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "6,300.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,450.00",
            "TOWER 2 [P]": "11,025.00",
            "TOWER 3 [Q]": "11,025.00",
            "TOWER 4 [R]": "9,450.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/455-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "CCTV Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From security control room to security monitor points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — CCTV Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From security control room to security monitor points",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 18900,
          "amount_state": "number",
          "printed_page": "2/R/156",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23390
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/455-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "ANPR camera",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — ANPR camera",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 19425,
          "amount_aed": 174825,
          "amount_state": "number",
          "printed_page": "2/R/156",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23394
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "174,825.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/456",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 7771900,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/456-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor dome: detection",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor dome: detection",
          "quantity": 431,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 1508500,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23409
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "32",
            "Tower 1 [E]": "91",
            "Tower 2 [F]": "108",
            "Tower 3 [G]": "105",
            "Tower 4 [H]": "95",
            "TOTAL QTY [I]": "431",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "112,000.00",
            "TOWER 1 [O]": "318,500.00",
            "TOWER 2 [P]": "378,000.00",
            "TOWER 3 [Q]": "367,500.00",
            "TOWER 4 [R]": "332,500.00",
            "[S]": "TRUE",
            "[T]": "14000"
          }
        },
        {
          "id": "2 - Main/456-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor dome: identification",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor dome: identification",
          "quantity": 62,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 217000,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23411
          },
          "extra_columns": {
            "Basement [C]": "18",
            "GF & Podium [D]": "44",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "62",
            "BASEMENTS [M]": "63,000.00",
            "GF & PODIUM [N]": "154,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor dome: observation",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor dome: observation",
          "quantity": 1161,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 4063500,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23413
          },
          "extra_columns": {
            "Basement [C]": "24",
            "GF & Podium [D]": "109",
            "Tower 1 [E]": "234",
            "Tower 2 [F]": "273",
            "Tower 3 [G]": "264",
            "Tower 4 [H]": "257",
            "TOTAL QTY [I]": "1,161",
            "BASEMENTS [M]": "84,000.00",
            "GF & PODIUM [N]": "381,500.00",
            "TOWER 1 [O]": "819,000.00",
            "TOWER 2 [P]": "955,500.00",
            "TOWER 3 [Q]": "924,000.00",
            "TOWER 4 [R]": "899,500.00",
            "[S]": "TRUE",
            "[T]": "80500"
          }
        },
        {
          "id": "2 - Main/456-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor dome: recognition",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor dome: recognition",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 66500,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23415
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "19",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "66,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor wall (dome): detection",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor wall (dome): detection",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23417
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-F",
          "item_code": "F",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor wall (dome): identification",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor wall (dome): identification",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 42000,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23419
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "42,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-G",
          "item_code": "G",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor wall (dome): observation",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor wall (dome): observation",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23421
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "6",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-H",
          "item_code": "H",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed indoor wall (dome): recognition",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed indoor wall (dome): recognition",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 3500,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23423
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-J",
          "item_code": "J",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor pendant (dome): detection",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor pendant (dome): detection",
          "quantity": 158,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 647800,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23425
          },
          "extra_columns": {
            "Basement [C]": "98",
            "GF & Podium [D]": "60",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "158",
            "BASEMENTS [M]": "401,800.00",
            "GF & PODIUM [N]": "246,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-K",
          "item_code": "K",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor pendant (dome): recognition",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor pendant (dome): recognition",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 45100,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23427
          },
          "extra_columns": {
            "Basement [C]": "6",
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "24,600.00",
            "GF & PODIUM [N]": "20,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-L",
          "item_code": "L",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor wall: detection",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor wall: detection",
          "quantity": 44,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 180400,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23429
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "35",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "143,500.00",
            "TOWER 1 [O]": "12,300.00",
            "TOWER 2 [P]": "8,200.00",
            "TOWER 3 [Q]": "8,200.00",
            "TOWER 4 [R]": "8,200.00",
            "[S]": "TRUE",
            "[T]": "-4100"
          }
        },
        {
          "id": "2 - Main/456-M",
          "item_code": "M",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor wall: identification",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor wall: identification",
          "quantity": 47,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 192700,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23431
          },
          "extra_columns": {
            "Basement [C]": "35",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "143,500.00",
            "GF & PODIUM [N]": "49,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-N",
          "item_code": "N",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor wall: observation",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor wall: observation",
          "quantity": 21,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 86100,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23433
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "9",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,900.00",
            "TOWER 1 [O]": "12,300.00",
            "TOWER 2 [P]": "16,400.00",
            "TOWER 3 [Q]": "12,300.00",
            "TOWER 4 [R]": "8,200.00",
            "[S]": "TRUE",
            "[T]": "-4100"
          }
        },
        {
          "id": "2 - Main/456-P",
          "item_code": "P",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Fixed outdoor wall: recognition",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Fixed outdoor wall: recognition",
          "quantity": 22,
          "unit": "Nr.",
          "rate_aed": 4100,
          "amount_aed": 90200,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23435
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "22",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "90,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-Q",
          "item_code": "Q",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "100 x 50mm security cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 100 x 50mm security cable tray",
          "quantity": 5192,
          "unit": "m",
          "rate_aed": 80,
          "amount_aed": 415360,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23441
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "40",
            "Tower 2 [F]": "1,848",
            "Tower 3 [G]": "1,721",
            "Tower 4 [H]": "1,583",
            "TOTAL QTY [I]": "5,192",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,200.00",
            "TOWER 2 [P]": "147,840.00",
            "TOWER 3 [Q]": "137,680.00",
            "TOWER 4 [R]": "126,640.00",
            "[S]": "TRUE",
            "[T]": "123440"
          }
        },
        {
          "id": "2 - Main/456-R",
          "item_code": "R",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "150 x 50mm security cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 150 x 50mm security cable tray",
          "quantity": 90,
          "unit": "m",
          "rate_aed": 85,
          "amount_aed": 7650,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23443
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "90",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "90",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-S",
          "item_code": "S",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable tray"
          ],
          "own_description": "200 x 100mm security cable tray",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable tray — 200 x 100mm security cable tray",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23445
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/456-T",
          "item_code": "T",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "100 x 50mm security cable trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable trunking — 100 x 50mm security cable trunking",
          "quantity": 1529,
          "unit": "m",
          "rate_aed": 110,
          "amount_aed": 168190,
          "amount_state": "number",
          "printed_page": "2/R/157",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23449
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "1,529",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1,529",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "168,190.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "-168190"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/457",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 4684540,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/457-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "200 x 50mm GI trunking for security",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable trunking — 200 x 50mm GI trunking for security",
          "quantity": 370,
          "unit": "m",
          "rate_aed": 140,
          "amount_aed": 51800,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23461
          },
          "extra_columns": {
            "Basement [C]": "370",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "370",
            "BASEMENTS [M]": "51,800.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "300 x 50mm GI trunking for security",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable trunking — 300 x 50mm GI trunking for security",
          "quantity": 167,
          "unit": "m",
          "rate_aed": 130,
          "amount_aed": 21710,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23463
          },
          "extra_columns": {
            "Basement [C]": "167",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "167",
            "BASEMENTS [M]": "21,710.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary",
            "Cable trunking"
          ],
          "own_description": "200 x 100mm security cable trunking",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Containment; including fixings, supports, hangers, accessories and all ancillary works as necessary — Cable trunking — 200 x 100mm security cable trunking",
          "quantity": 783,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 172260,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23465
          },
          "extra_columns": {
            "Basement [C]": "658",
            "GF & Podium [D]": "125",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "783",
            "BASEMENTS [M]": "144,760.00",
            "GF & PODIUM [N]": "27,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "42U security rack, 800 x 800mm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — 42U security rack, 800 x 800mm",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 105000,
          "amount_aed": 3570000,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23469
          },
          "extra_columns": {
            "Basement [C]": "4",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "7",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "420,000.00",
            "GF & PODIUM [N]": "420,000.00",
            "TOWER 1 [O]": "630,000.00",
            "TOWER 2 [P]": "735,000.00",
            "TOWER 3 [Q]": "735,000.00",
            "TOWER 4 [R]": "630,000.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "55\" flat panel UHD display",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — 55\" flat panel UHD display",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 5250,
          "amount_aed": 63000,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23471
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "12",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "63,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-F",
          "item_code": "F",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to single door - door contact points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to single door - door contact points",
          "quantity": 715,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 225225,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23477
          },
          "extra_columns": {
            "Basement [C]": "33",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "145",
            "Tower 2 [F]": "168",
            "Tower 3 [G]": "165",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "715",
            "BASEMENTS [M]": "10,395.00",
            "GF & PODIUM [N]": "15,120.00",
            "TOWER 1 [O]": "45,675.00",
            "TOWER 2 [P]": "52,920.00",
            "TOWER 3 [Q]": "51,975.00",
            "TOWER 4 [R]": "49,140.00",
            "[S]": "TRUE",
            "[T]": "3465"
          }
        },
        {
          "id": "2 - Main/457-G",
          "item_code": "G",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to double door - door contact points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to double door - door contact points",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 6300,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23479
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "2,835.00",
            "GF & PODIUM [N]": "3,465.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-H",
          "item_code": "H",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to single leaf exit panic bar points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to single leaf exit panic bar points",
          "quantity": 675,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 212625,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23481
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "142",
            "Tower 2 [F]": "167",
            "Tower 3 [G]": "158",
            "Tower 4 [H]": "154",
            "TOTAL QTY [I]": "675",
            "BASEMENTS [M]": "945.00",
            "GF & PODIUM [N]": "16,065.00",
            "TOWER 1 [O]": "44,730.00",
            "TOWER 2 [P]": "52,605.00",
            "TOWER 3 [Q]": "49,770.00",
            "TOWER 4 [R]": "48,510.00",
            "[S]": "TRUE",
            "[T]": "3780"
          }
        },
        {
          "id": "2 - Main/457-J",
          "item_code": "J",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to  EL 1.0 points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to  EL 1.0 points",
          "quantity": 108,
          "unit": "Nr.",
          "rate_aed": 945,
          "amount_aed": 102060,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23483
          },
          "extra_columns": {
            "Basement [C]": "38",
            "GF & Podium [D]": "58",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "108",
            "BASEMENTS [M]": "35,910.00",
            "GF & PODIUM [N]": "54,810.00",
            "TOWER 1 [O]": "3,780.00",
            "TOWER 2 [P]": "3,780.00",
            "TOWER 3 [Q]": "1,890.00",
            "TOWER 4 [R]": "1,890.00",
            "[S]": "TRUE",
            "[T]": "-1890"
          }
        },
        {
          "id": "2 - Main/457-K",
          "item_code": "K",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to EML2.0 points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to EML2.0 points",
          "quantity": 113,
          "unit": "Nr.",
          "rate_aed": 2205,
          "amount_aed": 249165,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23485
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "81",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "37,485.00",
            "GF & PODIUM [N]": "178,605.00",
            "TOWER 1 [O]": "8,820.00",
            "TOWER 2 [P]": "11,025.00",
            "TOWER 3 [Q]": "4,410.00",
            "TOWER 4 [R]": "8,820.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-L",
          "item_code": "L",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to lift car reader points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to lift car reader points",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 8820,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23487
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/457-M",
          "item_code": "M",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to access control card encoder points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to access control card encoder points",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 1575,
          "amount_state": "number",
          "printed_page": "2/R/158",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23489
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,575.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/458",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 3400450,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/458-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to card reader points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to card reader points",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 315,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23502
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Access Control System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From access control panel to Equipment room security rack points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Access Control System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From access control panel to Equipment room security rack points",
          "quantity": 60,
          "unit": "Nr.",
          "rate_aed": 1575,
          "amount_aed": 94500,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23504
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "12,600.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,900.00",
            "TOWER 2 [P]": "22,050.00",
            "TOWER 3 [Q]": "22,050.00",
            "TOWER 4 [R]": "18,900.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Single door - door contact, ref: DC1",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Single door - door contact, ref: DC1",
          "quantity": 709,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 893340,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23508
          },
          "extra_columns": {
            "Basement [C]": "33",
            "GF & Podium [D]": "48",
            "Tower 1 [E]": "145",
            "Tower 2 [F]": "168",
            "Tower 3 [G]": "159",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "709",
            "BASEMENTS [M]": "41,580.00",
            "GF & PODIUM [N]": "60,480.00",
            "TOWER 1 [O]": "182,700.00",
            "TOWER 2 [P]": "211,680.00",
            "TOWER 3 [Q]": "200,340.00",
            "TOWER 4 [R]": "196,560.00",
            "[S]": "TRUE",
            "[T]": "13860"
          }
        },
        {
          "id": "2 - Main/458-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Double door - door contact, ref: DC2",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Double door - door contact, ref: DC2",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 25200,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23510
          },
          "extra_columns": {
            "Basement [C]": "9",
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "11,340.00",
            "GF & PODIUM [N]": "13,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Single leaf exit panic bar, ref DM1.",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Single leaf exit panic bar, ref DM1.",
          "quantity": 675,
          "unit": "Nr.",
          "rate_aed": 1260,
          "amount_aed": 850500,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23512
          },
          "extra_columns": {
            "Basement [C]": "3",
            "GF & Podium [D]": "51",
            "Tower 1 [E]": "142",
            "Tower 2 [F]": "167",
            "Tower 3 [G]": "158",
            "Tower 4 [H]": "154",
            "TOTAL QTY [I]": "675",
            "BASEMENTS [M]": "3,780.00",
            "GF & PODIUM [N]": "64,260.00",
            "TOWER 1 [O]": "178,920.00",
            "TOWER 2 [P]": "210,420.00",
            "TOWER 3 [Q]": "199,080.00",
            "TOWER 4 [R]": "194,040.00",
            "[S]": "TRUE",
            "[T]": "15120"
          }
        },
        {
          "id": "2 - Main/458-F",
          "item_code": "F",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Single leaf access controlled door with card reader, electric mortise lock and door contact, ref: EL 1.0",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Single leaf access controlled door with card reader, electric mortise lock and door contact, ref: EL 1.0",
          "quantity": 108,
          "unit": "Nr.",
          "rate_aed": 3205,
          "amount_aed": 346140,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23514
          },
          "extra_columns": {
            "Basement [C]": "38",
            "GF & Podium [D]": "58",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "108",
            "BASEMENTS [M]": "121,790.00",
            "GF & PODIUM [N]": "185,890.00",
            "TOWER 1 [O]": "12,820.00",
            "TOWER 2 [P]": "12,820.00",
            "TOWER 3 [Q]": "6,410.00",
            "TOWER 4 [R]": "6,410.00",
            "[S]": "TRUE",
            "[T]": "-6410"
          }
        },
        {
          "id": "2 - Main/458-G",
          "item_code": "G",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Double leaf access controlled door system with card reader, magnetic locks, door contacts, break glass unit and push button, ref  EML2.0",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Double leaf access controlled door system with card reader, magnetic locks, door contacts, break glass unit and push button, ref  EML2.0",
          "quantity": 113,
          "unit": "Nr.",
          "rate_aed": 6880,
          "amount_aed": 777440,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23516
          },
          "extra_columns": {
            "Basement [C]": "17",
            "GF & Podium [D]": "81",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "5",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "113",
            "BASEMENTS [M]": "116,960.00",
            "GF & PODIUM [N]": "557,280.00",
            "TOWER 1 [O]": "27,520.00",
            "TOWER 2 [P]": "34,400.00",
            "TOWER 3 [Q]": "13,760.00",
            "TOWER 4 [R]": "27,520.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-H",
          "item_code": "H",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Lift car reader, ref: LCR",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Lift car reader, ref: LCR",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 685,
          "amount_aed": 19180,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23518
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "28",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,180.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-J",
          "item_code": "J",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Access control card encoder",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Access control card encoder",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 7500,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23520
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-K",
          "item_code": "K",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Card reader, ref: CR",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Card reader, ref: CR",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 3700,
          "amount_aed": 37000,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23522
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/458-L",
          "item_code": "L",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Access control panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Access control panel",
          "quantity": 60,
          "unit": "Nr.",
          "rate_aed": 5775,
          "amount_aed": 346500,
          "amount_state": "number",
          "printed_page": "2/R/159",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23526
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "0",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "60",
            "BASEMENTS [M]": "46,200.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "69,300.00",
            "TOWER 2 [P]": "80,850.00",
            "TOWER 3 [Q]": "80,850.00",
            "TOWER 4 [R]": "69,300.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/459",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 604250,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/459-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary"
          ],
          "own_description": "Boom gate barrier: arm length 2.75 meters",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary — Boom gate barrier: arm length 2.75 meters",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 105000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23546
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "105,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary"
          ],
          "own_description": "Boom gate barrier: arm length 3.25 meters",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary — Boom gate barrier: arm length 3.25 meters",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18000,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23548
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary"
          ],
          "own_description": "Boom gate barrier: arm length 5.75 meters",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Gate barrier system equipment / devices, as approved by the Engineer, including power operated automatic drop arm, magnetic loops, safety loops, control modules, wiring, labeling, fixings and all ancillary works as necessary — Boom gate barrier: arm length 5.75 meters",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 32000,
          "amount_aed": 32000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23550
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to button switch points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to button switch points",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23556
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to duress button points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to duress button points",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23558
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-F",
          "item_code": "F",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to entry intercom points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to entry intercom points",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23560
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-G",
          "item_code": "G",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to guard unit intercom, points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to guard unit intercom, points",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 3750,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23562
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-H",
          "item_code": "H",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to lift emergency call intercom point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to lift emergency call intercom point",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 250,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23564
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-J",
          "item_code": "J",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to security intercom door station points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to security intercom door station points",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 7500,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23566
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "4,000.00",
            "GF & PODIUM [N]": "3,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-K",
          "item_code": "K",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to panic alarm sounder point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to panic alarm sounder point",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 250,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23568
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/459-L",
          "item_code": "L",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From audio intercom panel to room intercom points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From audio intercom panel to room intercom points",
          "quantity": 1730,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 432500,
          "amount_state": "number",
          "printed_page": "2/R/160",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23570
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "379",
            "Tower 2 [F]": "433",
            "Tower 3 [G]": "455",
            "Tower 4 [H]": "402",
            "TOTAL QTY [I]": "1,730",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,250.00",
            "TOWER 1 [O]": "94,750.00",
            "TOWER 2 [P]": "108,250.00",
            "TOWER 3 [Q]": "113,750.00",
            "TOWER 4 [R]": "100,500.00",
            "[S]": "TRUE",
            "[T]": "5750"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/460",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 1723465,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/460-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Intercom System Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From equipment room security rack to audio intercom panel points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Intercom System Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From equipment room security rack to audio intercom panel points",
          "quantity": 77,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 19250,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23583
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "16",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "18",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "4,000.00",
            "TOWER 2 [P]": "4,500.00",
            "TOWER 3 [Q]": "4,500.00",
            "TOWER 4 [R]": "4,250.00",
            "[S]": "TRUE",
            "[T]": "250"
          }
        },
        {
          "id": "2 - Main/460-B",
          "item_code": "B",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Button switch, ref: BS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Button switch, ref: BS",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 415,
          "amount_aed": 1660,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23587
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-C",
          "item_code": "C",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Duress button, ref: D",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Duress button, ref: D",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 415,
          "amount_aed": 3320,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23589
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-D",
          "item_code": "D",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Entry intercom, ref: EI",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Entry intercom, ref: EI",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 15750,
          "amount_aed": 126000,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23591
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "126,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-E",
          "item_code": "E",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Guard unit intercom, ref: GI",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Guard unit intercom, ref: GI",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 75000,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23593
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "75,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-F",
          "item_code": "F",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Lift emergency call intercom",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Lift emergency call intercom",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3675,
          "amount_aed": 3675,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23595
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,675.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-G",
          "item_code": "G",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Security intercom door station, ref: SI",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Security intercom door station, ref: SI",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 3675,
          "amount_aed": 110250,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23597
          },
          "extra_columns": {
            "Basement [C]": "16",
            "GF & Podium [D]": "14",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "58,800.00",
            "GF & PODIUM [N]": "51,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-H",
          "item_code": "H",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Panic alarm sounder, ref PA-S:",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Panic alarm sounder, ref PA-S:",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 410,
          "amount_aed": 410,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23599
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "410.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/460-J",
          "item_code": "J",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "Room intercom, ref: RI",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary works as necessary — Room intercom, ref: RI",
          "quantity": 1730,
          "unit": "Nr.",
          "rate_aed": 630,
          "amount_aed": 1089900,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23601
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "61",
            "Tower 1 [E]": "379",
            "Tower 2 [F]": "433",
            "Tower 3 [G]": "455",
            "Tower 4 [H]": "402",
            "TOTAL QTY [I]": "1,730",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "38,430.00",
            "TOWER 1 [O]": "238,770.00",
            "TOWER 2 [P]": "272,790.00",
            "TOWER 3 [Q]": "286,650.00",
            "TOWER 4 [R]": "253,260.00",
            "[S]": "TRUE",
            "[T]": "14490"
          }
        },
        {
          "id": "2 - Main/460-K",
          "item_code": "K",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Audio intercom panel, ref: AD",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interconnecting cables, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Audio intercom panel, ref: AD",
          "quantity": 77,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 231000,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23605
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "8",
            "Tower 1 [E]": "16",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "18",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "77",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,000.00",
            "TOWER 1 [O]": "48,000.00",
            "TOWER 2 [P]": "54,000.00",
            "TOWER 3 [Q]": "54,000.00",
            "TOWER 4 [R]": "51,000.00",
            "[S]": "TRUE",
            "[T]": "3000"
          }
        },
        {
          "id": "2 - Main/460-L",
          "item_code": "L",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ACS system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — To ACS system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23609
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/460-M",
          "item_code": "M",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "To ANPR system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — To ANPR system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23611
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/460-N",
          "item_code": "N",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "To intercom system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — To intercom system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23613
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/460-P",
          "item_code": "P",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "To key management system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — To key management system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/161",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23615
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/461",
      "section": "SECURITY INSTALLATION",
      "sheet": "2 - Main",
      "source_collection_aed": 15750,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/461-A",
          "item_code": "A",
          "section": "SECURITY INSTALLATION",
          "heading_path": [
            "Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "To video management system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SECURITY INSTALLATION — Workstation; including computers, monitors, printers, software, accessories and all ancillary works as necessary — To video management system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 15750,
          "amount_aed": 15750,
          "amount_state": "number",
          "printed_page": "2/R/162",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23628
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/462",
      "section": "BUILDING MANAGEMENT SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 14848720,
      "section_notes": [
        "Note: Refer to the following",
        "1. BMS Drawing Nr. ZD-3250587-CKR-DWG-ZZZ-MEC-2610 to 2618",
        "2. MEP Specifications; ZD-3250587-CKR-GE-SP-M-1000"
      ],
      "items": [
        {
          "id": "2 - Main/462-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From BMS IP network to DDC points",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From BMS IP network to DDC points",
          "quantity": 40,
          "unit": "Nr.",
          "rate_aed": 371218,
          "amount_aed": 14848720,
          "amount_state": "number",
          "printed_page": "2/R/163",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23692
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "2,969,744.00",
            "GF & PODIUM [N]": "7,424,360.00",
            "TOWER 1 [O]": "1,113,654.00",
            "TOWER 2 [P]": "1,113,654.00",
            "TOWER 3 [Q]": "1,113,654.00",
            "TOWER 4 [R]": "1,113,654.00",
            "[S]": "TRUE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/462-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "From BMS IP network to BMS workstation point",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — From BMS IP network to BMS workstation point",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/163",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23694
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/462-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Direct digital control, DDC",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Equipment; including active and passive network components, terminations, software, configuration, setup and programming, interface connections, fixings, supports, hangers, accessories and all ancillary works as necessary — Direct digital control, DDC",
          "quantity": 40,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/163",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23698
          },
          "extra_columns": {
            "Basement [C]": "8",
            "GF & Podium [D]": "20",
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/462-D",
          "item_code": "D",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Workstation; including computers, monitors, software, accessories and all ancillary works as necessary"
          ],
          "own_description": "BMS workstation including alarm printer",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Workstation; including computers, monitors, software, accessories and all ancillary works as necessary — BMS workstation including alarm printer",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/163",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23702
          },
          "extra_columns": {
            "Basement [C]": "0",
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "0",
            "Tower 2 [F]": "0",
            "Tower 3 [G]": "0",
            "Tower 4 [H]": "0",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE",
            "[T]": "0"
          }
        },
        {
          "id": "2 - Main/462-E",
          "item_code": "E",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To ACB trip status",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To ACB trip status",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/163",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23706
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/463",
      "section": "BUILDING MANAGEMENT SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/463-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To access control panel (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To access control panel (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23720
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To BCWS pumps",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To BCWS pumps",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23722
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To booster pumps",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To booster pumps",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23724
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-D",
          "item_code": "D",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To CBS panel (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To CBS panel (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23726
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-E",
          "item_code": "E",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To CCTV system (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To CCTV system (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23728
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-F",
          "item_code": "F",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To chemical dosing unit system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To chemical dosing unit system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23730
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-G",
          "item_code": "G",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To chilled water pumps",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To chilled water pumps",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23732
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-H",
          "item_code": "H",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To clean agent fire suppression system (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To clean agent fire suppression system (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23734
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-J",
          "item_code": "J",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To common fault alarm",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To common fault alarm",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23736
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-K",
          "item_code": "K",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To co-monitoring panel",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To co-monitoring panel",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23738
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-L",
          "item_code": "L",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To co-monitoring/sensor",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To co-monitoring/sensor",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23740
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-M",
          "item_code": "M",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To domestic water pumps (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To domestic water pumps (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23742
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-N",
          "item_code": "N",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To elevators (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To elevators (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23744
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-P",
          "item_code": "P",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To extract fan",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To extract fan",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23746
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-Q",
          "item_code": "Q",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To FAHU",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To FAHU",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23748
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-R",
          "item_code": "R",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To fire alarm panel (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To fire alarm panel (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23750
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-S",
          "item_code": "S",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To fire pump (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To fire pump (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23752
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-T",
          "item_code": "T",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To FLS fans and dampers (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To FLS fans and dampers (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23754
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-U",
          "item_code": "U",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To FLS fans/MSFD's (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To FLS fans/MSFD's (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23756
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-V",
          "item_code": "V",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To garbage extract fans (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To garbage extract fans (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23758
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/463-W",
          "item_code": "W",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To gate barrier (thru FAS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To gate barrier (thru FAS)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/164",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23760
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/464",
      "section": "BUILDING MANAGEMENT SYSTEM",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/464-A",
          "item_code": "A",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To GEF-1 & 2 (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To GEF-1 & 2 (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23775
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-B",
          "item_code": "B",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To generator (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To generator (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23777
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-C",
          "item_code": "C",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To integrated panel with ATS",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To integrated panel with ATS",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23779
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-D",
          "item_code": "D",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To irrigation water pumps (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To irrigation water pumps (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23781
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-E",
          "item_code": "E",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To jet fan (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To jet fan (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23783
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-F",
          "item_code": "F",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To lighting control system (control and monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To lighting control system (control and monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23785
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-G",
          "item_code": "G",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To LPG detecting panel (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To LPG detecting panel (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23787
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-H",
          "item_code": "H",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To LPG tank high level alarm (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To LPG tank high level alarm (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23789
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-J",
          "item_code": "J",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To LV/EMU (current/voltage) (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To LV/EMU (current/voltage) (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23791
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-K",
          "item_code": "K",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To motor control centres",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To motor control centres",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23793
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-L",
          "item_code": "L",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To MFSD (smoke control) (thru FAS)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To MFSD (smoke control) (thru FAS)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23795
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-M",
          "item_code": "M",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To PMU's",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To PMU's",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23797
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-N",
          "item_code": "N",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To pool plant equipment (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To pool plant equipment (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23799
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-P",
          "item_code": "P",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To pressurization unit system",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To pressurization unit system",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23801
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-Q",
          "item_code": "Q",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To sump pumps",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To sump pumps",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23803
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-R",
          "item_code": "R",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To supply fans",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To supply fans",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23805
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-S",
          "item_code": "S",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To thermostat (common area)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To thermostat (common area)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23807
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-T",
          "item_code": "T",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To UPS for security system (monitoring)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To UPS for security system (monitoring)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23809
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-U",
          "item_code": "U",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To water tank level (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To water tank level (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23811
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/464-V",
          "item_code": "V",
          "section": "BUILDING MANAGEMENT SYSTEM",
          "heading_path": [
            "Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete"
          ],
          "own_description": "To water transfer pumps (monitoring only)",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — BUILDING MANAGEMENT SYSTEM — Building Management Systems (BMS) to interface with other systems and all associated automatic controls and monitoring system; including cabling, containment, BMS devices, terminations, fixings, supports, fittings, accessories and all ancillary works as necessary; complete — To water transfer pumps (monitoring only)",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "printed_page": "2/R/165",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23813
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/465",
      "section": "SUNDRIES",
      "sheet": "2 - Main",
      "source_collection_aed": 11884550.25,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/465-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23828
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/465-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all identification including painting, marking and labeling",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for all identification including painting, marking and labeling",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23830
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/465-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 11884477.120954089,
          "amount_aed": 11884550.25,
          "amount_state": "number",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23832
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,884,477.12",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/465-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23834
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/465-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing spares for the Electrical Engineering Installation",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for providing spares for the Electrical Engineering Installation",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23836
          },
          "extra_columns": {
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "2 - Main/465-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — SUNDRIES — Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/166",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23838
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/466",
      "section": "WORK INCIDENTAL AND BWIC",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/466-A",
          "item_code": "A",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23869
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-B",
          "item_code": "B",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23871
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-C",
          "item_code": "C",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23873
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-D",
          "item_code": "D",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23875
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-E",
          "item_code": "E",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23877
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-F",
          "item_code": "F",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for fire stopping all cables, conduit, trucking, cable tray and the like at penetrations through fire walls and other structures and making good",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for fire stopping all cables, conduit, trucking, cable tray and the like at penetrations through fire walls and other structures and making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23879
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-G",
          "item_code": "G",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23881
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/466-H",
          "item_code": "H",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all protective painting including removing protective coatings or wrappings and cleaning exposed surfaces for Electrical installations.",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for all protective painting including removing protective coatings or wrappings and cleaning exposed surfaces for Electrical installations.",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/167",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23883
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/467",
      "section": "WORK INCIDENTAL AND BWIC",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/467-A",
          "item_code": "A",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all decorative painting including removing protective coatings or wrappings and cleaning exposed surfaces for Electrical installations.",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for all decorative painting including removing protective coatings or wrappings and cleaning exposed surfaces for Electrical installations.",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/168",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23911
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/467-B",
          "item_code": "B",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for training the Employer's Staff to operate and maintain the Electrical Engineering Installations",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for training the Employer's Staff to operate and maintain the Electrical Engineering Installations",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/168",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23913
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/467-C",
          "item_code": "C",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work to the Electrical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Work Incidental to Electrical Engineering Installations — Allow for all incidental work to the Electrical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/168",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23915
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        },
        {
          "id": "2 - Main/467-D",
          "item_code": "D",
          "section": "WORK INCIDENTAL AND BWIC",
          "heading_path": [
            "Builders work in connection (BWIC) with Electrical Engineering Installations"
          ],
          "own_description": "Allow for all BWIC with Electrical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — WORK INCIDENTAL AND BWIC — Builders work in connection (BWIC) with Electrical Engineering Installations — Allow for all BWIC with Electrical Engineering Installations where not included above or elsewhere",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "2/R/168",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23919
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "FALSE"
          }
        }
      ]
    },
    {
      "page_ref": "2 - Main/468",
      "section": "GENERALLY",
      "sheet": "2 - Main",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "2 - Main/468-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Electrical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 2 — SECTION R - ELECTRICAL INSTALLATIONS (2/R) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Electrical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "2/R/169",
          "bill_ref": "2",
          "section_ref": "2/R",
          "source": {
            "sheet": "2 - Main",
            "row": 23955
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/1",
      "section": "PAVING AND SURFACING",
      "sheet": "3 - Ext",
      "source_collection_aed": 6850450,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/1-A",
          "item_code": "A",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Driveway paving; granite paving; flamed and sandblasted (staggered pattern); dark grey color; 150 x 100 x 80mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works"
          ],
          "own_description": "Paving type PD-01-A",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Driveway paving; granite paving; flamed and sandblasted (staggered pattern); dark grey color; 150 x 100 x 80mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works — Paving type PD-01-A",
          "quantity": 5492,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 3569800,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 11
          },
          "extra_columns": {
            "GF & Podium [D]": "5,492",
            "TOTAL QTY [I]": "5,492",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,569,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-B",
          "item_code": "B",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Pedestrian paving; granite paving; honed and scored (staggered pattern); medium grey color; 900 x 300 x 50mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works"
          ],
          "own_description": "Paving type PD-01-B",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Pedestrian paving; granite paving; honed and scored (staggered pattern); medium grey color; 900 x 300 x 50mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works — Paving type PD-01-B",
          "quantity": 4222,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 2744300,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 15
          },
          "extra_columns": {
            "GF & Podium [D]": "4,222",
            "TOTAL QTY [I]": "4,222",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,744,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-C",
          "item_code": "C",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Control band; limestone; cleft finish; medium beige color; 600 x 400 x 30mm;  with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works"
          ],
          "own_description": "Paving type PD-01-D",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Control band; limestone; cleft finish; medium beige color; 600 x 400 x 30mm;  with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works — Paving type PD-01-D",
          "quantity": 76,
          "unit": "m2",
          "rate_aed": 300,
          "amount_aed": 22800,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 19
          },
          "extra_columns": {
            "GF & Podium [D]": "76",
            "TOTAL QTY [I]": "76",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-r23",
          "item_code": "",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Podium Coping Tile - Planter Walls & Shower Walls - R10 Structured Non-Slip Porcelain Tile - Colour: Light Beige(Stone Effect) - Size: 1200X600mm_30mm With A 3mm Joint"
          ],
          "own_description": "Paving type PD-02-B",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Podium Coping Tile - Planter Walls & Shower Walls - R10 Structured Non-Slip Porcelain Tile - Colour: Light Beige(Stone Effect) - Size: 1200X600mm_30mm With A 3mm Joint — Paving type PD-02-B",
          "quantity": 38,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 13300,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 23
          },
          "extra_columns": {
            "GF & Podium [D]": "38",
            "TOTAL QTY [I]": "38",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-D",
          "item_code": "D",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Feature paving; granite paving; flamed (stack bond perpendicular to road); dark grey color; 450 x 75 x 80/50mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works"
          ],
          "own_description": "Paving type PD-01-E",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Feature paving; granite paving; flamed (stack bond perpendicular to road); dark grey color; 450 x 75 x 80/50mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints and all necessary ancillary works — Paving type PD-01-E",
          "quantity": 540,
          "unit": "m2",
          "rate_aed": 650,
          "amount_aed": 351000,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 27
          },
          "extra_columns": {
            "GF & Podium [D]": "540",
            "TOTAL QTY [I]": "540",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "351,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-E",
          "item_code": "E",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Transition kerb; granite; honed finish; dark grey color;  including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works"
          ],
          "own_description": "Transition kerb; kerb type PD-01-C",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Transition kerb; granite; honed finish; dark grey color;  including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works — Transition kerb; kerb type PD-01-C",
          "quantity": 30,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 11250,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 31
          },
          "extra_columns": {
            "GF & Podium [D]": "30",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-F",
          "item_code": "F",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Roll over kerb; granite; honed finish; dark grey color; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works"
          ],
          "own_description": "Roll over kerb; kerb type PD-01-F",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Roll over kerb; granite; honed finish; dark grey color; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works — Roll over kerb; kerb type PD-01-F",
          "quantity": 284,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 106500,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 35
          },
          "extra_columns": {
            "GF & Podium [D]": "284",
            "TOTAL QTY [I]": "284",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "106,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/1-G",
          "item_code": "G",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Flush kerb; granite; honed finish; dark grey color; 600x 150mm; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works"
          ],
          "own_description": "Flush kerb; kerb type PD-01-G",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Flush kerb; granite; honed finish; dark grey color; 600x 150mm; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works — Flush kerb; kerb type PD-01-G",
          "quantity": 84,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 31500,
          "amount_state": "number",
          "printed_page": "3/B/1",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 39
          },
          "extra_columns": {
            "GF & Podium [D]": "84",
            "TOTAL QTY [I]": "84",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/2",
      "section": "GATE",
      "sheet": "3 - Ext",
      "source_collection_aed": 1718720,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/2-A",
          "item_code": "A",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Upstand kerb; granite; honed finish; dark grey color; 600x 150mm; 150mm thick; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works"
          ],
          "own_description": "Upstand kerb; kerb type PD-01-H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Upstand kerb; granite; honed finish; dark grey color; 600x 150mm; 150mm thick; including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works — Upstand kerb; kerb type PD-01-H",
          "quantity": 1292,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 484500,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 51
          },
          "extra_columns": {
            "GF & Podium [D]": "1,292",
            "TOTAL QTY [I]": "1,292",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "484,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-B",
          "item_code": "B",
          "section": "PAVING AND SURFACING",
          "heading_path": [
            "Gravel Mulch; crushed pea gravel; river washed finish; dark grey mix; 20-40;  including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works"
          ],
          "own_description": "Gravel mulch; type PD-01-I",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — PAVING AND SURFACING — Gravel Mulch; crushed pea gravel; river washed finish; dark grey mix; 20-40;  including foundation, haunching, finishes, mortar bed, jointing and pointing and all necessary ancillary works — Gravel mulch; type PD-01-I",
          "quantity": 577,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 28850,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 55
          },
          "extra_columns": {
            "GF & Podium [D]": "577",
            "TOTAL QTY [I]": "577",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-C",
          "item_code": "C",
          "section": "FENCING",
          "heading_path": [
            "Podium deck glass balustrade; frameless glass balustrade; including all necessary ancillary works"
          ],
          "own_description": "Type L-F4; size 1200mm H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — FENCING — Podium deck glass balustrade; frameless glass balustrade; including all necessary ancillary works — Type L-F4; size 1200mm H",
          "quantity": 606,
          "unit": "m",
          "rate_aed": 1500,
          "amount_aed": 909000,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 61
          },
          "extra_columns": {
            "GF & Podium [D]": "606",
            "TOTAL QTY [I]": "606",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "909,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-D",
          "item_code": "D",
          "section": "FENCING",
          "heading_path": [
            "Podium deck aluminum balustrade - powder coated aluminium in a Jotun 0406 Champagne colour - 1200mm height with 25mm mullions at 100mm spacing; including all necessary ancillary works"
          ],
          "own_description": "Type L-F5; size 1200mm H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — FENCING — Podium deck aluminum balustrade - powder coated aluminium in a Jotun 0406 Champagne colour - 1200mm height with 25mm mullions at 100mm spacing; including all necessary ancillary works — Type L-F5; size 1200mm H",
          "quantity": 223,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 267600,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 65
          },
          "extra_columns": {
            "GF & Podium [D]": "223",
            "TOTAL QTY [I]": "223",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "267,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-E",
          "item_code": "E",
          "section": "GATE",
          "heading_path": [
            "Podium security gate - powder coated Jotun 0406 Champagne colour - 1200X1200mm_50mm - aluminium double leaf gate with fire escape ironmongery fitted; including all necessary ancillary works"
          ],
          "own_description": "Type L-F1; size 1200 x 1200mm H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Podium security gate - powder coated Jotun 0406 Champagne colour - 1200X1200mm_50mm - aluminium double leaf gate with fire escape ironmongery fitted; including all necessary ancillary works — Type L-F1; size 1200 x 1200mm H",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1440,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 71
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-F",
          "item_code": "F",
          "section": "GATE",
          "heading_path": [
            "Podium maintenance area security gate; frameless glass gate; including all necessary ancillary works"
          ],
          "own_description": "Type L-F2; size 600 x 1200mm H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Podium maintenance area security gate; frameless glass gate; including all necessary ancillary works — Type L-F2; size 600 x 1200mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1010,
          "amount_aed": 1010,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 75
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,010.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/2-G",
          "item_code": "G",
          "section": "GATE",
          "heading_path": [
            "Podium kids pool glass gate; frameless glass balustrade; including all necessary ancillary works"
          ],
          "own_description": "Type L-F3; size 1300 x 1200mm H",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Podium kids pool glass gate; frameless glass balustrade; including all necessary ancillary works — Type L-F3; size 1300 x 1200mm H",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 2200,
          "amount_aed": 22000,
          "amount_state": "number",
          "printed_page": "3/B/2",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 79
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/3",
      "section": "GATE",
      "sheet": "3 - Ext",
      "source_collection_aed": 3907496,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/3-A",
          "item_code": "A",
          "section": "GATE",
          "heading_path": [
            "Drainage cell; wrap in 2 layer geotextile fabric (measured separately); including all ancillary works as necessary"
          ],
          "own_description": "To landscape area; horizontally",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Drainage cell; wrap in 2 layer geotextile fabric (measured separately); including all ancillary works as necessary — To landscape area; horizontally",
          "quantity": 5435,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 434800,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 101
          },
          "extra_columns": {
            "GF & Podium [D]": "5,351",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "5,435",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "428,080.00",
            "TOWER 1 [O]": "1,760.00",
            "TOWER 2 [P]": "1,600.00",
            "TOWER 3 [Q]": "1,760.00",
            "TOWER 4 [R]": "1,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-B",
          "item_code": "B",
          "section": "GATE",
          "heading_path": [
            "Drainage cell; wrap in 2 layer geotextile fabric (measured separately); including all ancillary works as necessary"
          ],
          "own_description": "To landscape area; vertically",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Drainage cell; wrap in 2 layer geotextile fabric (measured separately); including all ancillary works as necessary — To landscape area; vertically",
          "quantity": 9650,
          "unit": "m2",
          "rate_aed": 80,
          "amount_aed": 772000,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 103
          },
          "extra_columns": {
            "GF & Podium [D]": "9,322",
            "Tower 1 [E]": "84",
            "Tower 2 [F]": "80",
            "Tower 3 [G]": "84",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "9,650",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "745,760.00",
            "TOWER 1 [O]": "6,720.00",
            "TOWER 2 [P]": "6,400.00",
            "TOWER 3 [Q]": "6,720.00",
            "TOWER 4 [R]": "6,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-C",
          "item_code": "C",
          "section": "GATE",
          "heading_path": [
            "Approved geotextile fabric 2 layers - top & bottom of drainage cell layers"
          ],
          "own_description": "To landscape area; horizontally",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Approved geotextile fabric 2 layers - top & bottom of drainage cell layers — To landscape area; horizontally",
          "quantity": 5435,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 48915,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 107
          },
          "extra_columns": {
            "GF & Podium [D]": "5,351",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "5,435",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,159.00",
            "TOWER 1 [O]": "198.00",
            "TOWER 2 [P]": "180.00",
            "TOWER 3 [Q]": "198.00",
            "TOWER 4 [R]": "180.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-D",
          "item_code": "D",
          "section": "GATE",
          "heading_path": [
            "Approved geotextile fabric 2 layers - top & bottom of drainage cell layers"
          ],
          "own_description": "To landscape area; vertically",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Approved geotextile fabric 2 layers - top & bottom of drainage cell layers — To landscape area; vertically",
          "quantity": 9650,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 86850,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 109
          },
          "extra_columns": {
            "GF & Podium [D]": "9,322",
            "Tower 1 [E]": "84",
            "Tower 2 [F]": "80",
            "Tower 3 [G]": "84",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "9,650",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "83,898.00",
            "TOWER 1 [O]": "756.00",
            "TOWER 2 [P]": "720.00",
            "TOWER 3 [Q]": "756.00",
            "TOWER 4 [R]": "720.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-E",
          "item_code": "E",
          "section": "GATE",
          "heading_path": [
            "For planting medium, including fertilizer and all ancillary works as necessary where not measured separately"
          ],
          "own_description": "To planters",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — For planting medium, including fertilizer and all ancillary works as necessary where not measured separately — To planters",
          "quantity": 9701.8,
          "unit": "m3",
          "rate_aed": 150,
          "amount_aed": 1455270,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 113
          },
          "extra_columns": {
            "GF & Podium [D]": "9,559",
            "Tower 1 [E]": "37",
            "Tower 2 [F]": "34",
            "Tower 3 [G]": "37",
            "Tower 4 [H]": "34",
            "TOTAL QTY [I]": "9,702",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,433,850.00",
            "TOWER 1 [O]": "5,610.00",
            "TOWER 2 [P]": "5,100.00",
            "TOWER 3 [Q]": "5,610.00",
            "TOWER 4 [R]": "5,100.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-F",
          "item_code": "F",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: P-Ph-da; phoenix dactylifera; date palm; clear trunk height: 3.00-4.00m; 350-400mm caliper; 5.50-6.00m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: P-Ph-da; phoenix dactylifera; date palm; clear trunk height: 3.00-4.00m; 350-400mm caliper; 5.50-6.00m overall height",
          "quantity": 65,
          "unit": "Nr.",
          "rate_aed": 5828,
          "amount_aed": 378820,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 117
          },
          "extra_columns": {
            "GF & Podium [D]": "65",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "378,820.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-G",
          "item_code": "G",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Po-gl-(S); pongamia glabra (Specimen); pongam tree; clear trunk height: 2.00-2.20m; 120-150mm caliper; 3.00-3.50m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Po-gl-(S); pongamia glabra (Specimen); pongam tree; clear trunk height: 2.00-2.20m; 120-150mm caliper; 3.00-3.50m overall height",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 2600,
          "amount_aed": 41600,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 119
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "41,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-H",
          "item_code": "H",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Ol-eu (SML); olea europea; domestic olive; clear trunk height: 0.5-1.0m; 80-120mm caliper; 1.5-1.8m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Ol-eu (SML); olea europea; domestic olive; clear trunk height: 0.5-1.0m; 80-120mm caliper; 1.5-1.8m overall height",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 5800,
          "amount_aed": 52200,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 121
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "52,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-J",
          "item_code": "J",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Pl-ob(SP); plumeria obtusa in pot; singapore or white fig tree; clear trunk height: 1.8-2.0m; 80-100mm caliper; 2.5-3.0m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Pl-ob(SP); plumeria obtusa in pot; singapore or white fig tree; clear trunk height: 1.8-2.0m; 80-100mm caliper; 2.5-3.0m overall height",
          "quantity": 35,
          "unit": "Nr.",
          "rate_aed": 4812,
          "amount_aed": 168420,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 123
          },
          "extra_columns": {
            "GF & Podium [D]": "35",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "168,420.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-K",
          "item_code": "K",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Ol-eu (S); olea europea (specimen); domestic olive (specimen); clear trunk height: 1.0-1.5m; 300-500mm caliper; 3.0-4.0m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Ol-eu (S); olea europea (specimen); domestic olive (specimen); clear trunk height: 1.0-1.5m; 300-500mm caliper; 3.0-4.0m overall height",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 7035,
          "amount_aed": 21105,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 125
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,105.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/3-L",
          "item_code": "L",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Pl-ob; plumeria obtusa; singapore or white fig tree; clear trunk height: 1.80-2.00m; 80-100mm caliper; 2.5-3.0m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Pl-ob; plumeria obtusa; singapore or white fig tree; clear trunk height: 1.80-2.00m; 80-100mm caliper; 2.5-3.0m overall height",
          "quantity": 93,
          "unit": "Nr.",
          "rate_aed": 4812,
          "amount_aed": 447516,
          "amount_state": "number",
          "printed_page": "3/B/3",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 127
          },
          "extra_columns": {
            "GF & Podium [D]": "93",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "447,516.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/4",
      "section": "SUNDRIES",
      "sheet": "3 - Ext",
      "source_collection_aed": 2238380,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/4-A",
          "item_code": "A",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Pl-ob (S); plumeria obtusa specimen; singapore or white fig tree; clear trunk height: 1.00-1.50m; 120-180mm caliper; 3.0-3.5m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Pl-ob (S); plumeria obtusa specimen; singapore or white fig tree; clear trunk height: 1.00-1.50m; 120-180mm caliper; 3.0-3.5m overall height",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 3800,
          "amount_aed": 174800,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 146
          },
          "extra_columns": {
            "GF & Podium [D]": "46",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "174,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-B",
          "item_code": "B",
          "section": "GATE",
          "heading_path": [
            "Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary"
          ],
          "own_description": "Code: T-Po-gl; pongamia glabra; pongam tree; clear trunk height: 1.80-2.00m; 80-100mm caliper; 2.5-3.0m overall height",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting trees using root ball fixing system; including transportation and handling, mulching, tree stake, proprietary tree tie, non-woven geotextile, root ball protection mess and the like as necessary — Code: T-Po-gl; pongamia glabra; pongam tree; clear trunk height: 1.80-2.00m; 80-100mm caliper; 2.5-3.0m overall height",
          "quantity": 124,
          "unit": "Nr.",
          "rate_aed": 2100,
          "amount_aed": 260400,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 148
          },
          "extra_columns": {
            "GF & Podium [D]": "124",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "260,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-C",
          "item_code": "C",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: GR-Pe-se; pennisetum setaceum; african fountain grass",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: GR-Pe-se; pennisetum setaceum; african fountain grass",
          "quantity": 93,
          "unit": "m2",
          "rate_aed": 100,
          "amount_aed": 9300,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 152
          },
          "extra_columns": {
            "GF & Podium [D]": "93",
            "TOTAL QTY [I]": "93",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-D",
          "item_code": "D",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: G-Ca-pe / G-Ca-ro; catharanthus (pentunie & roseus); madagascar periwinkle",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: G-Ca-pe / G-Ca-ro; catharanthus (pentunie & roseus); madagascar periwinkle",
          "quantity": 18,
          "unit": "m2",
          "rate_aed": 175,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 154
          },
          "extra_columns": {
            "GF & Podium [D]": "18",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-E",
          "item_code": "E",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: G-Ru-ci; ruellia ciliosa; wild petunia",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: G-Ru-ci; ruellia ciliosa; wild petunia",
          "quantity": 174,
          "unit": "m2",
          "rate_aed": 250,
          "amount_aed": 43500,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 156
          },
          "extra_columns": {
            "GF & Podium [D]": "174",
            "TOTAL QTY [I]": "174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "43,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-F",
          "item_code": "F",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: L-Pa-va; paspallum vaginatum; sea papalum (instant)",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: L-Pa-va; paspallum vaginatum; sea papalum (instant)",
          "quantity": 1051,
          "unit": "m2",
          "rate_aed": 38,
          "amount_aed": 39938,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 158
          },
          "extra_columns": {
            "GF & Podium [D]": "1,051",
            "TOTAL QTY [I]": "1,051",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "39,938.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-G",
          "item_code": "G",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: S-Cl-in (H); clerodendrum inerme (hedge); false jasmine",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: S-Cl-in (H); clerodendrum inerme (hedge); false jasmine",
          "quantity": 3572,
          "unit": "m2",
          "rate_aed": 331,
          "amount_aed": 1182332,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 160
          },
          "extra_columns": {
            "GF & Podium [D]": "3,488",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "3,572",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,154,528.00",
            "TOWER 1 [O]": "7,282.00",
            "TOWER 2 [P]": "6,620.00",
            "TOWER 3 [Q]": "7,282.00",
            "TOWER 4 [R]": "6,620.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-H",
          "item_code": "H",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: S-Cr-as; crinum asiaticum; giant spider lily",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: S-Cr-as; crinum asiaticum; giant spider lily",
          "quantity": 183,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 27450,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 162
          },
          "extra_columns": {
            "GF & Podium [D]": "183",
            "TOTAL QTY [I]": "183",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-J",
          "item_code": "J",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: G-Hy-li; hymenocallis littoralis; beach spider lily",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: G-Hy-li; hymenocallis littoralis; beach spider lily",
          "quantity": 513,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 76950,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 164
          },
          "extra_columns": {
            "GF & Podium [D]": "513",
            "TOTAL QTY [I]": "513",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "76,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-K",
          "item_code": "K",
          "section": "GATE",
          "heading_path": [
            "Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary"
          ],
          "own_description": "Code: SU-Ag-at; agave attenuata; foxtail",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GATE — Supply and planting shrubs and ground covers  as detailed including transportation and handling, supports, mulching and the like as necessary — Code: SU-Ag-at; agave attenuata; foxtail",
          "quantity": 588,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 70560,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 166
          },
          "extra_columns": {
            "GF & Podium [D]": "588",
            "TOTAL QTY [I]": "588",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "70,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-L",
          "item_code": "L",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for planting edging",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — SUNDRIES — Allow for planting edging",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 30000,
          "amount_aed": 30000,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 170
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "30,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-M",
          "item_code": "M",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for maintenance of soft landscaping works during defect liability period for a period of one year after the date of Taking over Certificate and for complying with all the requirements",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — SUNDRIES — Allow for maintenance of soft landscaping works during defect liability period for a period of one year after the date of Taking over Certificate and for complying with all the requirements",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 300000,
          "amount_aed": 300000,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 172
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "300,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/4-N",
          "item_code": "N",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for the provision of water only for maintenance purpose during defect liability period",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — SUNDRIES — Allow for the provision of water only for maintenance purpose during defect liability period",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 20000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "3/B/4",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 174
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "20,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/5",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/5-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Site Works in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION B - SITE WORKS (3/B) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Site Works in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/B/5",
          "bill_ref": "3",
          "section_ref": "3/B",
          "source": {
            "sheet": "3 - Ext",
            "row": 197
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/6",
      "section": "POURED CONCRETE",
      "sheet": "3 - Ext",
      "source_collection_aed": 4464940,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/6-A",
          "item_code": "A",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Sand cement screed; blinding layer; concrete grade C20/25"
          ],
          "own_description": "100mm thick; to soft landscape areas",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Sand cement screed; blinding layer; concrete grade C20/25 — 100mm thick; to soft landscape areas",
          "quantity": 619,
          "unit": "m3",
          "rate_aed": 500,
          "amount_aed": 309500,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 326
          },
          "extra_columns": {
            "GF & Podium [D]": "535",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "619",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "267,500.00",
            "TOWER 1 [O]": "11,000.00",
            "TOWER 2 [P]": "10,000.00",
            "TOWER 3 [Q]": "11,000.00",
            "TOWER 4 [R]": "10,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-B",
          "item_code": "B",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Planter walls",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Planter walls",
          "quantity": 2304,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 1382400,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 330
          },
          "extra_columns": {
            "GF & Podium [D]": "2,230",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "19",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "2,304",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,338,000.00",
            "TOWER 1 [O]": "11,400.00",
            "TOWER 2 [P]": "10,800.00",
            "TOWER 3 [Q]": "11,400.00",
            "TOWER 4 [R]": "10,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-C",
          "item_code": "C",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Upstands",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Upstands",
          "quantity": 585,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 351000,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 332
          },
          "extra_columns": {
            "GF & Podium [D]": "555",
            "Tower 1 [E]": "8",
            "Tower 2 [F]": "7",
            "Tower 3 [G]": "8",
            "Tower 4 [H]": "7",
            "TOTAL QTY [I]": "585",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "333,000.00",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "4,200.00",
            "TOWER 3 [Q]": "4,800.00",
            "TOWER 4 [R]": "4,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-D",
          "item_code": "D",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Secondary slabs; 150mm thick",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Secondary slabs; 150mm thick",
          "quantity": 4,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 334
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-E",
          "item_code": "E",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Secondary slabs; 200mm thick",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Secondary slabs; 200mm thick",
          "quantity": 404,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 242400,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 336
          },
          "extra_columns": {
            "GF & Podium [D]": "270",
            "Tower 1 [E]": "36",
            "Tower 2 [F]": "31",
            "Tower 3 [G]": "36",
            "Tower 4 [H]": "31",
            "TOTAL QTY [I]": "404",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "162,000.00",
            "TOWER 1 [O]": "21,600.00",
            "TOWER 2 [P]": "18,600.00",
            "TOWER 3 [Q]": "21,600.00",
            "TOWER 4 [R]": "18,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-F",
          "item_code": "F",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete; concrete grade C50/60"
          ],
          "own_description": "Stair & steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete; concrete grade C50/60 — Stair & steps",
          "quantity": 13,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 338
          },
          "extra_columns": {
            "GF & Podium [D]": "13",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-G",
          "item_code": "G",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Pool walls",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Pool walls",
          "quantity": 276,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 165600,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 342
          },
          "extra_columns": {
            "GF & Podium [D]": "210",
            "Tower 1 [E]": "17",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "17",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "276",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "126,000.00",
            "TOWER 1 [O]": "10,200.00",
            "TOWER 2 [P]": "9,600.00",
            "TOWER 3 [Q]": "10,200.00",
            "TOWER 4 [R]": "9,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-H",
          "item_code": "H",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary"
          ],
          "own_description": "Steps to swimming pools",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Watertight construction concrete; concrete grade C50/60; including water bars, water stops, sealant, accessories and all ancillary works as necessary — Steps to swimming pools",
          "quantity": 19,
          "unit": "m3",
          "rate_aed": 600,
          "amount_aed": 11400,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 344
          },
          "extra_columns": {
            "GF & Podium [D]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-J",
          "item_code": "J",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Light weight concrete fill; with maximum density of 10kN/m³; including concrete screed (measured separately), accessories, and all ancillary works as necessary"
          ],
          "own_description": "To make-up levels; various thickness",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Light weight concrete fill; with maximum density of 10kN/m³; including concrete screed (measured separately), accessories, and all ancillary works as necessary — To make-up levels; various thickness",
          "quantity": 804,
          "unit": "m3",
          "rate_aed": 400,
          "amount_aed": 321600,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 348
          },
          "extra_columns": {
            "GF & Podium [D]": "662",
            "Tower 1 [E]": "29",
            "Tower 2 [F]": "42",
            "Tower 3 [G]": "29",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "804",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "264,800.00",
            "TOWER 1 [O]": "11,600.00",
            "TOWER 2 [P]": "16,800.00",
            "TOWER 3 [Q]": "11,600.00",
            "TOWER 4 [R]": "16,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-K",
          "item_code": "K",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete screed; on EPS insulation (measured separately)"
          ],
          "own_description": "100mm thick",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete screed; on EPS insulation (measured separately) — 100mm thick",
          "quantity": 502,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 175700,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 352
          },
          "extra_columns": {
            "GF & Podium [D]": "434",
            "Tower 1 [E]": "18",
            "Tower 2 [F]": "16",
            "Tower 3 [G]": "18",
            "Tower 4 [H]": "16",
            "TOTAL QTY [I]": "502",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "151,900.00",
            "TOWER 1 [O]": "6,300.00",
            "TOWER 2 [P]": "5,600.00",
            "TOWER 3 [Q]": "6,300.00",
            "TOWER 4 [R]": "5,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-L",
          "item_code": "L",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Reinforced concrete screed; on EPS insulation (measured separately)"
          ],
          "own_description": "150mm thick",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Reinforced concrete screed; on EPS insulation (measured separately) — 150mm thick",
          "quantity": 1662,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 581700,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 354
          },
          "extra_columns": {
            "GF & Podium [D]": "1,662",
            "TOTAL QTY [I]": "1,662",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "581,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-M",
          "item_code": "M",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification"
          ],
          "own_description": "To swimming pool; horizontally",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification — To swimming pool; horizontally",
          "quantity": 1314,
          "unit": "m2",
          "rate_aed": 330,
          "amount_aed": 433620,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 358
          },
          "extra_columns": {
            "GF & Podium [D]": "1,040",
            "Tower 1 [E]": "66",
            "Tower 2 [F]": "71",
            "Tower 3 [G]": "66",
            "Tower 4 [H]": "71",
            "TOTAL QTY [I]": "1,314",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "343,200.00",
            "TOWER 1 [O]": "21,780.00",
            "TOWER 2 [P]": "23,430.00",
            "TOWER 3 [Q]": "21,780.00",
            "TOWER 4 [R]": "23,430.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-N",
          "item_code": "N",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification"
          ],
          "own_description": "To swimming pool; vertically",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification — To swimming pool; vertically",
          "quantity": 1055,
          "unit": "m2",
          "rate_aed": 330,
          "amount_aed": 348150,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 360
          },
          "extra_columns": {
            "GF & Podium [D]": "701",
            "Tower 1 [E]": "88",
            "Tower 2 [F]": "89",
            "Tower 3 [G]": "88",
            "Tower 4 [H]": "89",
            "TOTAL QTY [I]": "1,055",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "231,330.00",
            "TOWER 1 [O]": "29,040.00",
            "TOWER 2 [P]": "29,370.00",
            "TOWER 3 [Q]": "29,040.00",
            "TOWER 4 [R]": "29,370.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-P",
          "item_code": "P",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification"
          ],
          "own_description": "To water feature; horizontally",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification — To water feature; horizontally",
          "quantity": 327,
          "unit": "m2",
          "rate_aed": 330,
          "amount_aed": 107910,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 362
          },
          "extra_columns": {
            "GF & Podium [D]": "301",
            "Tower 2 [F]": "13",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "327",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "99,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,290.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,290.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/6-Q",
          "item_code": "Q",
          "section": "POURED CONCRETE",
          "heading_path": [
            "Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification"
          ],
          "own_description": "To water feature; vertically",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — POURED CONCRETE — Pneumatically applied concrete (gunite); grade C35 in accordance with BS 8110; as per Specification — To water feature; vertically",
          "quantity": 72,
          "unit": "m2",
          "rate_aed": 330,
          "amount_aed": 23760,
          "amount_state": "number",
          "printed_page": "3/C/1",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 364
          },
          "extra_columns": {
            "GF & Podium [D]": "56",
            "Tower 2 [F]": "8",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "72",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,640.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,640.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/7",
      "section": "SHUTTERING",
      "sheet": "3 - Ext",
      "source_collection_aed": 7903335,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/7-A",
          "item_code": "A",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Planter wall; various diameter",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Planter wall; various diameter",
          "quantity": 276,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 1324800,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 386
          },
          "extra_columns": {
            "GF & Podium [D]": "268.00",
            "Tower 1 [E]": "2.00",
            "Tower 2 [F]": "2.00",
            "Tower 3 [G]": "2.00",
            "Tower 4 [H]": "2.00",
            "TOTAL QTY [I]": "276.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,286,400.00",
            "TOWER 1 [O]": "9,600.00",
            "TOWER 2 [P]": "9,600.00",
            "TOWER 3 [Q]": "9,600.00",
            "TOWER 4 [R]": "9,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-B",
          "item_code": "B",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Upstands; various diameter",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Upstands; various diameter",
          "quantity": 71,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 340800,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 388
          },
          "extra_columns": {
            "GF & Podium [D]": "67.00",
            "Tower 1 [E]": "1.00",
            "Tower 2 [F]": "1.00",
            "Tower 3 [G]": "1.00",
            "Tower 4 [H]": "1.00",
            "TOTAL QTY [I]": "71.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "321,600.00",
            "TOWER 1 [O]": "4,800.00",
            "TOWER 2 [P]": "4,800.00",
            "TOWER 3 [Q]": "4,800.00",
            "TOWER 4 [R]": "4,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-C",
          "item_code": "C",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Secondary slabs; various diameter",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Secondary slabs; various diameter",
          "quantity": 80,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 384000,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 390
          },
          "extra_columns": {
            "GF & Podium [D]": "54.00",
            "Tower 1 [E]": "7.00",
            "Tower 2 [F]": "6.00",
            "Tower 3 [G]": "7.00",
            "Tower 4 [H]": "6.00",
            "TOTAL QTY [I]": "80.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "259,200.00",
            "TOWER 1 [O]": "33,600.00",
            "TOWER 2 [P]": "28,800.00",
            "TOWER 3 [Q]": "33,600.00",
            "TOWER 4 [R]": "28,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-D",
          "item_code": "D",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Stair & steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Stair & steps",
          "quantity": 3,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 392
          },
          "extra_columns": {
            "GF & Podium [D]": "3.00",
            "TOTAL QTY [I]": "3.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-E",
          "item_code": "E",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Pool walls; various diameter",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Pool walls; various diameter",
          "quantity": 46,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 220800,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 394
          },
          "extra_columns": {
            "GF & Podium [D]": "34.00",
            "Tower 1 [E]": "3.00",
            "Tower 2 [F]": "3.00",
            "Tower 3 [G]": "3.00",
            "Tower 4 [H]": "3.00",
            "TOTAL QTY [I]": "46.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "163,200.00",
            "TOWER 1 [O]": "14,400.00",
            "TOWER 2 [P]": "14,400.00",
            "TOWER 3 [Q]": "14,400.00",
            "TOWER 4 [R]": "14,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-F",
          "item_code": "F",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Reinforcing steel bars; high yield deformed; grade 60"
          ],
          "own_description": "Steps to swimming pools",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Reinforcing steel bars; high yield deformed; grade 60 — Steps to swimming pools",
          "quantity": 4,
          "unit": "t",
          "rate_aed": 4800,
          "amount_aed": 19200,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 396
          },
          "extra_columns": {
            "GF & Podium [D]": "4.00",
            "TOTAL QTY [I]": "4.00",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "19,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-G",
          "item_code": "G",
          "section": "REINFORCEMENT",
          "heading_path": [
            "Mesh reinforcement; including accessories and all ancillary works as necessary"
          ],
          "own_description": "A252; single later; to light weight fill",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — REINFORCEMENT — Mesh reinforcement; including accessories and all ancillary works as necessary — A252; single later; to light weight fill",
          "quantity": 16088,
          "unit": "m2",
          "rate_aed": 35,
          "amount_aed": 563080,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 400
          },
          "extra_columns": {
            "GF & Podium [D]": "15,420",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "156",
            "Tower 3 [G]": "178",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "16,088",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "539,700.00",
            "TOWER 1 [O]": "6,230.00",
            "TOWER 2 [P]": "5,460.00",
            "TOWER 3 [Q]": "6,230.00",
            "TOWER 4 [R]": "5,460.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-H",
          "item_code": "H",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary",
            "Shuttering; plain formed finish"
          ],
          "own_description": "Planter walls",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Shuttering; plain formed finish — Planter walls",
          "quantity": 22862,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 3543610,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 408
          },
          "extra_columns": {
            "GF & Podium [D]": "22,206",
            "Tower 1 [E]": "168",
            "Tower 2 [F]": "160",
            "Tower 3 [G]": "168",
            "Tower 4 [H]": "160",
            "TOTAL QTY [I]": "22,862",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,441,930.00",
            "TOWER 1 [O]": "26,040.00",
            "TOWER 2 [P]": "24,800.00",
            "TOWER 3 [Q]": "26,040.00",
            "TOWER 4 [R]": "24,800.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-J",
          "item_code": "J",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary",
            "Shuttering; plain formed finish"
          ],
          "own_description": "Upstands",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Shuttering; plain formed finish — Upstands",
          "quantity": 5578,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 864590,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 410
          },
          "extra_columns": {
            "GF & Podium [D]": "5,398",
            "Tower 1 [E]": "48",
            "Tower 2 [F]": "42",
            "Tower 3 [G]": "48",
            "Tower 4 [H]": "42",
            "TOTAL QTY [I]": "5,578",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "836,690.00",
            "TOWER 1 [O]": "7,440.00",
            "TOWER 2 [P]": "6,510.00",
            "TOWER 3 [Q]": "7,440.00",
            "TOWER 4 [R]": "6,510.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-K",
          "item_code": "K",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary",
            "Shuttering; plain formed finish"
          ],
          "own_description": "Sides of pool walls",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Shuttering; plain formed finish — Sides of pool walls",
          "quantity": 2048,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 317440,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 412
          },
          "extra_columns": {
            "GF & Podium [D]": "1,660",
            "Tower 1 [E]": "100",
            "Tower 2 [F]": "94",
            "Tower 3 [G]": "100",
            "Tower 4 [H]": "94",
            "TOTAL QTY [I]": "2,048",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "257,300.00",
            "TOWER 1 [O]": "15,500.00",
            "TOWER 2 [P]": "14,570.00",
            "TOWER 3 [Q]": "15,500.00",
            "TOWER 4 [R]": "14,570.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-L",
          "item_code": "L",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary",
            "Shuttering; plain formed finish"
          ],
          "own_description": "To riser in swimming pool steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Shuttering; plain formed finish — To riser in swimming pool steps",
          "quantity": 33,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 5115,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 414
          },
          "extra_columns": {
            "GF & Podium [D]": "33",
            "TOTAL QTY [I]": "33",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,115.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-M",
          "item_code": "M",
          "section": "SHUTTERING",
          "heading_path": [
            "Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary",
            "Shuttering; plain formed finish"
          ],
          "own_description": "To riser in stairs & steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Formwork system; including design, supports, formed finishes, temporary works, accessories and all ancillary works as necessary — Shuttering; plain formed finish — To riser in stairs & steps",
          "quantity": 20,
          "unit": "m2",
          "rate_aed": 155,
          "amount_aed": 3100,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 416
          },
          "extra_columns": {
            "GF & Podium [D]": "20",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-N",
          "item_code": "N",
          "section": "SHUTTERING",
          "heading_path": [
            "Left-in formwork"
          ],
          "own_description": "To secondary slabs",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Left-in formwork — To secondary slabs",
          "quantity": 2036,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 285040,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 420
          },
          "extra_columns": {
            "GF & Podium [D]": "1,368",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "156",
            "Tower 3 [G]": "178",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "2,036",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "191,520.00",
            "TOWER 1 [O]": "24,920.00",
            "TOWER 2 [P]": "21,840.00",
            "TOWER 3 [Q]": "24,920.00",
            "TOWER 4 [R]": "21,840.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-P",
          "item_code": "P",
          "section": "SHUTTERING",
          "heading_path": [
            "Left-in formwork"
          ],
          "own_description": "Sloping soffits, soffits of swimming pool steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Left-in formwork — Sloping soffits, soffits of swimming pool steps",
          "quantity": 75,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 422
          },
          "extra_columns": {
            "GF & Podium [D]": "75",
            "TOTAL QTY [I]": "75",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/7-Q",
          "item_code": "Q",
          "section": "SHUTTERING",
          "heading_path": [
            "Left-in formwork"
          ],
          "own_description": "Sloping soffits, soffits of stairs & steps",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SHUTTERING — Left-in formwork — Sloping soffits, soffits of stairs & steps",
          "quantity": 49,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 6860,
          "amount_state": "number",
          "printed_page": "3/C/2",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 424
          },
          "extra_columns": {
            "GF & Podium [D]": "49",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,860.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/8",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 666250,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/8-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Expansion joint including necessary proprietary systems, water stops, sealant and all necessary accessories to complete",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — SUNDRIES — Expansion joint including necessary proprietary systems, water stops, sealant and all necessary accessories to complete",
          "quantity": 533,
          "unit": "m",
          "rate_aed": 1250,
          "amount_aed": 666250,
          "amount_state": "number",
          "printed_page": "3/C/3",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 446
          },
          "extra_columns": {
            "GF & Podium [D]": "533",
            "TOTAL QTY [I]": "533",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "666,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/8-B",
          "item_code": "B",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Concrete Works in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION C - CONCRETE WORKS (3/C) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Concrete Works in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/C/3",
          "bill_ref": "3",
          "section_ref": "3/C",
          "source": {
            "sheet": "3 - Ext",
            "row": 451
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/9",
      "section": "NON-STRUCTURAL METALWORK",
      "sheet": "3 - Ext",
      "source_collection_aed": 337040,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/9-A",
          "item_code": "A",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "Floor mounted; type LF-01-B; to pool 1",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — Floor mounted; type LF-01-B; to pool 1",
          "quantity": 10,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 572
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-B",
          "item_code": "B",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "Floor mounted; type LF-01-B; to pool 2",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — Floor mounted; type LF-01-B; to pool 2",
          "quantity": 18,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 21600,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 574
          },
          "extra_columns": {
            "GF & Podium [D]": "18",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-C",
          "item_code": "C",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "Floor mounted; type LF-01-B; to pool 4",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — Floor mounted; type LF-01-B; to pool 4",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 576
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-D",
          "item_code": "D",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "Floor mounted; type LF-01-D; to penthouse pool",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Handrail to pool; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — Floor mounted; type LF-01-D; to penthouse pool",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 578
          },
          "extra_columns": {
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "3,600.00",
            "TOWER 2 [P]": "3,600.00",
            "TOWER 3 [Q]": "3,600.00",
            "TOWER 4 [R]": "3,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-E",
          "item_code": "E",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Pool ladder"
          ],
          "own_description": "To swimming pool; Type LF-01-C",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Pool ladder — To swimming pool; Type LF-01-C",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 582
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-F",
          "item_code": "F",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Stair railing; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "Floor mounted; type LF-01-E",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Stair railing; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — Floor mounted; type LF-01-E",
          "quantity": 12,
          "unit": "m",
          "rate_aed": 1200,
          "amount_aed": 14400,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 586
          },
          "extra_columns": {
            "GF & Podium [D]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-G",
          "item_code": "G",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Landscape Edging; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete"
          ],
          "own_description": "To landscape; type LF-01-A",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Landscape Edging; measured flat on plan; brushed stainless steel 316 grade; natural; including fixing & accessories; complete — To landscape; type LF-01-A",
          "quantity": 180,
          "unit": "m",
          "rate_aed": 98,
          "amount_aed": 17640,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 590
          },
          "extra_columns": {
            "GF & Podium [D]": "180",
            "TOTAL QTY [I]": "180",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-H",
          "item_code": "H",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Rim flow grade type 01; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To pool; type SP-01-F",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Rim flow grade type 01; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary — To pool; type SP-01-F",
          "quantity": 116,
          "unit": "m",
          "rate_aed": 500,
          "amount_aed": 58000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 594
          },
          "extra_columns": {
            "GF & Podium [D]": "58",
            "Tower 2 [F]": "29",
            "Tower 4 [H]": "29",
            "TOTAL QTY [I]": "116",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "14,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "14,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-J",
          "item_code": "J",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Rim flow grade type 01; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To water feature; type WF-02-D",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Rim flow grade type 01; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary — To water feature; type WF-02-D",
          "quantity": 98,
          "unit": "m",
          "rate_aed": 500,
          "amount_aed": 49000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 596
          },
          "extra_columns": {
            "GF & Podium [D]": "98",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-K",
          "item_code": "K",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Rim flow grade type 02; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To pool; type SP-03-F",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Rim flow grade type 02; stainless steel; 316 grade; brushed finish; 960mm wide; 30mm thick;  including surface preparation and ancillary works as necessary — To pool; type SP-03-F",
          "quantity": 28,
          "unit": "m",
          "rate_aed": 500,
          "amount_aed": 14000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 600
          },
          "extra_columns": {
            "Tower 1 [E]": "14",
            "Tower 3 [G]": "14",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,000.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "7,000.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-L",
          "item_code": "L",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary"
          ],
          "own_description": "Size 300mm wide",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Heavy duty grating for drainage channel; type AM-321; fixed or removable metal grating; including finishes, fixings, frames, accessories and all ancillary works as necessary — Size 300mm wide",
          "quantity": 48,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 604
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/9-M",
          "item_code": "M",
          "section": "NON-STRUCTURAL METALWORK",
          "heading_path": [
            "Castle Tree Grate: stainless steel grade 316: by Green Blue Urban; MT-01-A; including accessories and all ancillary works as necessary"
          ],
          "own_description": "Castle tree grate; size 1500 x 1500mm",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — NON-STRUCTURAL METALWORK — Castle Tree Grate: stainless steel grade 316: by Green Blue Urban; MT-01-A; including accessories and all ancillary works as necessary — Castle tree grate; size 1500 x 1500mm",
          "quantity": 36,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 108000,
          "amount_state": "number",
          "printed_page": "3/E/1",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 608
          },
          "extra_columns": {
            "GF & Podium [D]": "36",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "108,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/10",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/10-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Metalwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION E - METALWORK (3/E) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Metalwork in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/E/2",
          "bill_ref": "3",
          "section_ref": "3/E",
          "source": {
            "sheet": "3 - Ext",
            "row": 624
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/11",
      "section": "INSULATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 19849160.12,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/11-A",
          "item_code": "A",
          "section": "WATERPROOFING",
          "heading_path": [
            "Waterproofing to landscape areas and terraces; as per Specification"
          ],
          "own_description": "5m thick waterproofing membrane on one layer of bituminous primer",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Waterproofing to landscape areas and terraces; as per Specification — 5m thick waterproofing membrane on one layer of bituminous primer",
          "quantity": 15243.720000000001,
          "unit": "m2",
          "rate_aed": 45,
          "amount_aed": 685967.4,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 752
          },
          "extra_columns": {
            "GF & Podium [D]": "13,667",
            "Tower 1 [E]": "389",
            "Tower 2 [F]": "417",
            "Tower 3 [G]": "389",
            "Tower 4 [H]": "383",
            "TOTAL QTY [I]": "15,244",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "615,015.00",
            "TOWER 1 [O]": "17,490.60",
            "TOWER 2 [P]": "18,750.60",
            "TOWER 3 [Q]": "17,490.60",
            "TOWER 4 [R]": "17,220.60",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-B",
          "item_code": "B",
          "section": "WATERPROOFING",
          "heading_path": [
            "Waterproofing to landscape areas and terraces; as per Specification"
          ],
          "own_description": "100mm thick extruded polystyrene boards",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Waterproofing to landscape areas and terraces; as per Specification — 100mm thick extruded polystyrene boards",
          "quantity": 15243.720000000001,
          "unit": "m2",
          "rate_aed": 67,
          "amount_aed": 1021329.2400000001,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 754
          },
          "extra_columns": {
            "GF & Podium [D]": "13,667",
            "Tower 1 [E]": "389",
            "Tower 2 [F]": "417",
            "Tower 3 [G]": "389",
            "Tower 4 [H]": "383",
            "TOTAL QTY [I]": "15,244",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "915,689.00",
            "TOWER 1 [O]": "26,041.56",
            "TOWER 2 [P]": "27,917.56",
            "TOWER 3 [Q]": "26,041.56",
            "TOWER 4 [R]": "25,639.56",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-C",
          "item_code": "C",
          "section": "WATERPROOFING",
          "heading_path": [
            "Waterproofing to landscape areas and terraces; as per Specification"
          ],
          "own_description": "polythene sheet",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Waterproofing to landscape areas and terraces; as per Specification — polythene sheet",
          "quantity": 15243.720000000001,
          "unit": "m2",
          "rate_aed": 9,
          "amount_aed": 137193.48,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 756
          },
          "extra_columns": {
            "GF & Podium [D]": "13,667",
            "Tower 1 [E]": "389",
            "Tower 2 [F]": "417",
            "Tower 3 [G]": "389",
            "Tower 4 [H]": "383",
            "TOTAL QTY [I]": "15,244",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "123,003.00",
            "TOWER 1 [O]": "3,498.12",
            "TOWER 2 [P]": "3,750.12",
            "TOWER 3 [Q]": "3,498.12",
            "TOWER 4 [R]": "3,444.12",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-D",
          "item_code": "D",
          "section": "WATERPROOFING",
          "heading_path": [
            "Cementitious waterproofing system to swimming pool; as per Specification"
          ],
          "own_description": "Horizontally",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Cementitious waterproofing system to swimming pool; as per Specification — Horizontally",
          "quantity": 1792,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 215040,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 760
          },
          "extra_columns": {
            "GF & Podium [D]": "1,506",
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "1,792",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "180,720.00",
            "TOWER 1 [O]": "8,400.00",
            "TOWER 2 [P]": "8,760.00",
            "TOWER 3 [Q]": "8,400.00",
            "TOWER 4 [R]": "8,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-E",
          "item_code": "E",
          "section": "WATERPROOFING",
          "heading_path": [
            "Cementitious waterproofing system to swimming pool; as per Specification"
          ],
          "own_description": "Vertically",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Cementitious waterproofing system to swimming pool; as per Specification — Vertically",
          "quantity": 928,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 111360,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 762
          },
          "extra_columns": {
            "GF & Podium [D]": "668",
            "Tower 1 [E]": "64",
            "Tower 2 [F]": "66",
            "Tower 3 [G]": "64",
            "Tower 4 [H]": "66",
            "TOTAL QTY [I]": "928",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80,160.00",
            "TOWER 1 [O]": "7,680.00",
            "TOWER 2 [P]": "7,920.00",
            "TOWER 3 [Q]": "7,680.00",
            "TOWER 4 [R]": "7,920.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-F",
          "item_code": "F",
          "section": "WATERPROOFING",
          "heading_path": [
            "Cementitious waterproofing system to water features; as per Specification"
          ],
          "own_description": "Horizontally",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Cementitious waterproofing system to water features; as per Specification — Horizontally",
          "quantity": 325,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 39000,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 766
          },
          "extra_columns": {
            "GF & Podium [D]": "301",
            "Tower 2 [F]": "12",
            "Tower 4 [H]": "12",
            "TOTAL QTY [I]": "325",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "36,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,440.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,440.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-G",
          "item_code": "G",
          "section": "WATERPROOFING",
          "heading_path": [
            "Cementitious waterproofing system to water features; as per Specification"
          ],
          "own_description": "Vertically",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Cementitious waterproofing system to water features; as per Specification — Vertically",
          "quantity": 66,
          "unit": "m2",
          "rate_aed": 120,
          "amount_aed": 7920,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 768
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "Tower 2 [F]": "9",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "66",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,080.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,080.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-H",
          "item_code": "H",
          "section": "WATERPROOFING",
          "heading_path": [
            "Waterproofing to planters; as per Specification"
          ],
          "own_description": "To planters area; horizontally",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Waterproofing to planters; as per Specification — To planters area; horizontally",
          "quantity": 5435,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 815250,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 772
          },
          "extra_columns": {
            "GF & Podium [D]": "5,351",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "20",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "20",
            "TOTAL QTY [I]": "5,435",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "802,650.00",
            "TOWER 1 [O]": "3,300.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,300.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-J",
          "item_code": "J",
          "section": "WATERPROOFING",
          "heading_path": [
            "Waterproofing to planters; as per Specification"
          ],
          "own_description": "To planters area; vertically",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — WATERPROOFING — Waterproofing to planters; as per Specification — To planters area; vertically",
          "quantity": 9650,
          "unit": "m2",
          "rate_aed": 150,
          "amount_aed": 1447500,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 774
          },
          "extra_columns": {
            "GF & Podium [D]": "9,322",
            "Tower 1 [E]": "84",
            "Tower 2 [F]": "80",
            "Tower 3 [G]": "84",
            "Tower 4 [H]": "80",
            "TOTAL QTY [I]": "9,650",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,398,300.00",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "12,000.00",
            "TOWER 3 [Q]": "12,600.00",
            "TOWER 4 [R]": "12,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/11-K",
          "item_code": "K",
          "section": "INSULATION",
          "heading_path": [
            "Expanded polystyrene fill (EPS); laid under cement sand screed (measured separately); minimum density 38kg/m3; maximum density 50kg/m3; minimum compressive resistance of 40kPa; including all ancillary works"
          ],
          "own_description": "Various thickness",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — INSULATION — Expanded polystyrene fill (EPS); laid under cement sand screed (measured separately); minimum density 38kg/m3; maximum density 50kg/m3; minimum compressive resistance of 40kPa; including all ancillary works — Various thickness",
          "quantity": 23644,
          "unit": "m3",
          "rate_aed": 650,
          "amount_aed": 15368600,
          "amount_state": "number",
          "printed_page": "3/G/1",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 781
          },
          "extra_columns": {
            "GF & Podium [D]": "22,522",
            "Tower 1 [E]": "297",
            "Tower 2 [F]": "264",
            "Tower 3 [G]": "297",
            "Tower 4 [H]": "264",
            "TOTAL QTY [I]": "23,644",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,639,300.00",
            "TOWER 1 [O]": "193,050.00",
            "TOWER 2 [P]": "171,600.00",
            "TOWER 3 [Q]": "193,050.00",
            "TOWER 4 [R]": "171,600.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/12",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/12-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Thermal and Moisture Protection in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION G - THERMAL AND MOISTURE PROTECTION (3/G) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Thermal and Moisture Protection in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/G/2",
          "bill_ref": "3",
          "section_ref": "3/G",
          "source": {
            "sheet": "3 - Ext",
            "row": 805
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/13",
      "section": "FLOOR FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 2466691.7800000003,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/13-A",
          "item_code": "A",
          "section": "FINISHES",
          "heading_path": [
            "Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories"
          ],
          "own_description": "To floors; to receive porcelain tiles",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories — To floors; to receive porcelain tiles",
          "quantity": 7671,
          "unit": "m2",
          "rate_aed": 55,
          "amount_aed": 421905,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 934
          },
          "extra_columns": {
            "GF & Podium [D]": "6,375",
            "Tower 1 [E]": "332",
            "Tower 2 [F]": "316",
            "Tower 3 [G]": "332",
            "Tower 4 [H]": "316",
            "TOTAL QTY [I]": "7,671",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "350,625.00",
            "TOWER 1 [O]": "18,260.00",
            "TOWER 2 [P]": "17,380.00",
            "TOWER 3 [Q]": "18,260.00",
            "TOWER 4 [R]": "17,380.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-B",
          "item_code": "B",
          "section": "FINISHES",
          "heading_path": [
            "Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories"
          ],
          "own_description": "To floors; to receive limestone tiles",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories — To floors; to receive limestone tiles",
          "quantity": 935,
          "unit": "m2",
          "rate_aed": 55,
          "amount_aed": 51425,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 936
          },
          "extra_columns": {
            "GF & Podium [D]": "695",
            "Tower 1 [E]": "57",
            "Tower 2 [F]": "80",
            "Tower 3 [G]": "57",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "935",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "38,225.00",
            "TOWER 1 [O]": "3,135.00",
            "TOWER 2 [P]": "4,400.00",
            "TOWER 3 [Q]": "3,135.00",
            "TOWER 4 [R]": "2,530.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-C",
          "item_code": "C",
          "section": "FINISHES",
          "heading_path": [
            "Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories"
          ],
          "own_description": "To floors; to receive granite tiles",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories — To floors; to receive granite tiles",
          "quantity": 242,
          "unit": "m2",
          "rate_aed": 55,
          "amount_aed": 13310,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 938
          },
          "extra_columns": {
            "GF & Podium [D]": "200",
            "Tower 2 [F]": "21",
            "Tower 4 [H]": "21",
            "TOTAL QTY [I]": "242",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,155.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,155.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-D",
          "item_code": "D",
          "section": "FINISHES",
          "heading_path": [
            "Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories"
          ],
          "own_description": "To floors; to receive rubber flooring",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories — To floors; to receive rubber flooring",
          "quantity": 117,
          "unit": "m2",
          "rate_aed": 55,
          "amount_aed": 6435,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 940
          },
          "extra_columns": {
            "GF & Podium [D]": "117",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,435.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-E",
          "item_code": "E",
          "section": "FINISHES",
          "heading_path": [
            "Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories"
          ],
          "own_description": "To floors; to receive polysoft material",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Concrete screeds and toppings; including surface preparation, joint-filler strips, joints, primers, additives and all necessary accessories — To floors; to receive polysoft material",
          "quantity": 80,
          "unit": "m2",
          "rate_aed": 55,
          "amount_aed": 4400,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 942
          },
          "extra_columns": {
            "GF & Podium [D]": "80",
            "TOTAL QTY [I]": "80",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-F",
          "item_code": "F",
          "section": "FINISHES",
          "heading_path": [
            "Cement and sand plaster; 15mm thick (minimum); including surface preparation and all ancillary works as necessary"
          ],
          "own_description": "To walls; to receive porcelain tile finish",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Cement and sand plaster; 15mm thick (minimum); including surface preparation and all ancillary works as necessary — To walls; to receive porcelain tile finish",
          "quantity": 1108,
          "unit": "m2",
          "rate_aed": 93,
          "amount_aed": 103044,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 946
          },
          "extra_columns": {
            "GF & Podium [D]": "1,104",
            "Tower 2 [F]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "1,108",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "102,672.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "186.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "186.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-G",
          "item_code": "G",
          "section": "FINISHES",
          "heading_path": [
            "Cement and sand plaster; 15mm thick (minimum); including surface preparation and all ancillary works as necessary"
          ],
          "own_description": "To walls; to receive granite tile finish",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FINISHES — Cement and sand plaster; 15mm thick (minimum); including surface preparation and all ancillary works as necessary — To walls; to receive granite tile finish",
          "quantity": 110.46000000000001,
          "unit": "m2",
          "rate_aed": 93,
          "amount_aed": 10272.78,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 948
          },
          "extra_columns": {
            "GF & Podium [D]": "110",
            "TOTAL QTY [I]": "110",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,272.78",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium main field; type PD-02-A; R11 structured non - slip porcelain tiles; light beige colour; size -1200 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To podium",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium main field; type PD-02-A; R11 structured non - slip porcelain tiles; light beige colour; size -1200 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To podium",
          "quantity": 5167,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 1808450,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 954
          },
          "extra_columns": {
            "GF & Podium [D]": "4,499",
            "Tower 1 [E]": "178",
            "Tower 2 [F]": "156",
            "Tower 3 [G]": "178",
            "Tower 4 [H]": "156",
            "TOTAL QTY [I]": "5,167",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,574,650.00",
            "TOWER 1 [O]": "62,300.00",
            "TOWER 2 [P]": "54,600.00",
            "TOWER 3 [Q]": "62,300.00",
            "TOWER 4 [R]": "54,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 180mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 180mm wide",
          "quantity": 133,
          "unit": "m",
          "rate_aed": 135,
          "amount_aed": 17955,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 958
          },
          "extra_columns": {
            "GF & Podium [D]": "133",
            "TOTAL QTY [I]": "133",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,955.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-K",
          "item_code": "K",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 200mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 200mm wide",
          "quantity": 69,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 10350,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 960
          },
          "extra_columns": {
            "GF & Podium [D]": "69",
            "TOTAL QTY [I]": "69",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-L",
          "item_code": "L",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 250mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 250mm wide",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 188,
          "amount_aed": 7520,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 962
          },
          "extra_columns": {
            "GF & Podium [D]": "40",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-M",
          "item_code": "M",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 300mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 300mm wide",
          "quantity": 50,
          "unit": "m",
          "rate_aed": 225,
          "amount_aed": 11250,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 964
          },
          "extra_columns": {
            "GF & Podium [D]": "50",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/13-N",
          "item_code": "N",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 500mm wide; to FHC",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 500mm wide; to FHC",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 375,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "3/J/1",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 966
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/14",
      "section": "FLOOR FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 637745,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/14-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 640mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 640mm wide",
          "quantity": 7,
          "unit": "m",
          "rate_aed": 480.00000000000006,
          "amount_aed": 3360.0000000000005,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 983
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 600mm wide",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium coping; type PD-02-B; R10 structured non - slip porcelain tiles;  light beige colour; 1200 x 600 x 30mm; with 3mm joint; including surface preparation and ancillary works as necessary — Size 600mm wide",
          "quantity": 31,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 13950,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 985
          },
          "extra_columns": {
            "GF & Podium [D]": "31",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,950.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium stair riser; type PD-02-D; Omani limestone; Honed; light beige - Grey colour; 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 150mm high",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium stair riser; type PD-02-D; Omani limestone; Honed; light beige - Grey colour; 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary — Size 150mm high",
          "quantity": 283,
          "unit": "m",
          "rate_aed": 600,
          "amount_aed": 169800,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 989
          },
          "extra_columns": {
            "GF & Podium [D]": "283",
            "TOTAL QTY [I]": "283",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "169,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium stair riser; type PD-02-D; Omani limestone; Honed; light beige - Grey colour; 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To seating",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium stair riser; type PD-02-D; Omani limestone; Honed; light beige - Grey colour; 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary — To seating",
          "quantity": 20,
          "unit": "m2",
          "rate_aed": 4000,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 991
          },
          "extra_columns": {
            "Tower 2 [F]": "10",
            "Tower 4 [H]": "10",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "40,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "40,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To tread",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary — To tread",
          "quantity": 100,
          "unit": "m2",
          "rate_aed": 700,
          "amount_aed": 70000,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 995
          },
          "extra_columns": {
            "GF & Podium [D]": "100",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "70,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size120mm H; stair riser to BBQ pit",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary — Size120mm H; stair riser to BBQ pit",
          "quantity": 95,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 14250,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 997
          },
          "extra_columns": {
            "GF & Podium [D]": "95",
            "TOTAL QTY [I]": "95",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To seating",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Stair tread coping; type PD-02-E; Omani limestone; light beige - Grey colour; Structured Non-Slip Porcelain Tile -\r\nColour: Light Beige (Stone Effect) 1200 x 600 x 30mm; with 3mm joint and sealant; including surface preparation and ancillary works as necessary — To seating",
          "quantity": 30,
          "unit": "m2",
          "rate_aed": 700,
          "amount_aed": 21000,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 999
          },
          "extra_columns": {
            "Tower 2 [F]": "15",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "30",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,500.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "To main field",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — To main field",
          "quantity": 200,
          "unit": "m2",
          "rate_aed": 700,
          "amount_aed": 140000,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1003
          },
          "extra_columns": {
            "GF & Podium [D]": "194",
            "Tower 1 [E]": "3",
            "Tower 3 [G]": "3",
            "TOTAL QTY [I]": "200",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "135,800.00",
            "TOWER 1 [O]": "2,100.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,100.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-J",
          "item_code": "J",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size  200mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size  200mm width",
          "quantity": 452,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 67800,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1005
          },
          "extra_columns": {
            "GF & Podium [D]": "422",
            "Tower 2 [F]": "15",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "452",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "63,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,250.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,250.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-K",
          "item_code": "K",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 140mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 140mm width",
          "quantity": 13,
          "unit": "m",
          "rate_aed": 105.00000000000001,
          "amount_aed": 1365.0000000000002,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1007
          },
          "extra_columns": {
            "GF & Podium [D]": "13",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,365.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-L",
          "item_code": "L",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 160mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 160mm width",
          "quantity": 44,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 5280,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1009
          },
          "extra_columns": {
            "Tower 1 [E]": "22",
            "Tower 3 [G]": "22",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,640.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "2,640.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-M",
          "item_code": "M",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 180mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 180mm width",
          "quantity": 21,
          "unit": "m",
          "rate_aed": 135,
          "amount_aed": 2835,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1011
          },
          "extra_columns": {
            "GF & Podium [D]": "21",
            "TOTAL QTY [I]": "21",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,835.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-N",
          "item_code": "N",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 240mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 240mm width",
          "quantity": 106,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 19080,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1013
          },
          "extra_columns": {
            "Tower 1 [E]": "53",
            "Tower 3 [G]": "53",
            "TOTAL QTY [I]": "106",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "9,540.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "9,540.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-P",
          "item_code": "P",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 300mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 300mm width",
          "quantity": 81,
          "unit": "m",
          "rate_aed": 225,
          "amount_aed": 18225,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1015
          },
          "extra_columns": {
            "GF & Podium [D]": "81",
            "TOTAL QTY [I]": "81",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,225.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/14-Q",
          "item_code": "Q",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary"
          ],
          "own_description": "Size 400mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Control band; type PD-02-F; Porcelain tile; light beige stone effect colour; 300 x 600 x 30mm; with 3mm joint with sealant; including surface preparation and ancillary works as necessary — Size 400mm width",
          "quantity": 36,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "3/J/2",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1017
          },
          "extra_columns": {
            "Tower 2 [F]": "18",
            "Tower 4 [H]": "18",
            "TOTAL QTY [I]": "36",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "5,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "5,400.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/15",
      "section": "FLOOR FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 792650,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/15-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium main field tile; type PD-02-G; R11 structured non - slip porcelain timber tiles; light ash teak colour; size -1200 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To podium main field",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium main field tile; type PD-02-G; R11 structured non - slip porcelain timber tiles; light ash teak colour; size -1200 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To podium main field",
          "quantity": 706,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 247100,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1039
          },
          "extra_columns": {
            "GF & Podium [D]": "706",
            "TOTAL QTY [I]": "706",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "247,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Podium main field tile; type PD-02-H; R11 structured non - slip ribbed porcelain tiles; warm - Grey colour; size - 600 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To podium main field",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Podium main field tile; type PD-02-H; R11 structured non - slip ribbed porcelain tiles; warm - Grey colour; size - 600 x 600mm_20mm with a 3mm joint;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To podium main field",
          "quantity": 23,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 8050,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1043
          },
          "extra_columns": {
            "GF & Podium [D]": "23",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Gravel infill; type PD-02-J; crushed pea gravel; river washed; dark - Grey mixed colour; 20 - 40mm; including all necessary ancillary works."
          ],
          "own_description": "To ground floor",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Gravel infill; type PD-02-J; crushed pea gravel; river washed; dark - Grey mixed colour; 20 - 40mm; including all necessary ancillary works. — To ground floor",
          "quantity": 40,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1047
          },
          "extra_columns": {
            "GF & Podium [D]": "40",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Gravel infill; type PD-02-J; crushed pea gravel; river washed; dark - Grey mixed colour; 20 - 40mm; including all necessary ancillary works."
          ],
          "own_description": "To podium deck",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Gravel infill; type PD-02-J; crushed pea gravel; river washed; dark - Grey mixed colour; 20 - 40mm; including all necessary ancillary works. — To podium deck",
          "quantity": 20,
          "unit": "m2",
          "rate_aed": 50,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1049
          },
          "extra_columns": {
            "GF & Podium [D]": "20",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "EPDM rubberized flooring - Type 01; colour & granule size specification: Teal - RAL 5018, SUR11121-902 and Type 03;  colour & granule size specification: Teal - RAL 5020, SUR11124-902;   laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To kids play area",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — EPDM rubberized flooring - Type 01; colour & granule size specification: Teal - RAL 5018, SUR11121-902 and Type 03;  colour & granule size specification: Teal - RAL 5020, SUR11124-902;   laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To kids play area",
          "quantity": 117,
          "unit": "m2",
          "rate_aed": 900,
          "amount_aed": 105300,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1053
          },
          "extra_columns": {
            "GF & Podium [D]": "117",
            "TOTAL QTY [I]": "117",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "105,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Internal floor finish; type SP-01-A; R11 structured; non - slip ribbed porcelain tiles; medium Grey colour; size -1200 x 600mm_20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Internal floor finish; type SP-01-A; R11 structured; non - slip ribbed porcelain tiles; medium Grey colour; size -1200 x 600mm_20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To pool",
          "quantity": 910,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 318500,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1057
          },
          "extra_columns": {
            "GF & Podium [D]": "910",
            "TOTAL QTY [I]": "910",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "318,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/15-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Internal floor finish; type SP-01-G; honed omani limestone tile; light beige-grey colour; size - 300 x 30mm thick; with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To pool step markers",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Internal floor finish; type SP-01-G; honed omani limestone tile; light beige-grey colour; size - 300 x 30mm thick; with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To pool step markers",
          "quantity": 246,
          "unit": "m",
          "rate_aed": 450,
          "amount_aed": 110700,
          "amount_state": "number",
          "printed_page": "3/J/3",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1061
          },
          "extra_columns": {
            "GF & Podium [D]": "246",
            "TOTAL QTY [I]": "246",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "110,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/16",
      "section": "FLOOR FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 316300,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/16-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Internal floor finish; type SP-02-A; R11 structured; non - slip ribbed porcelain tiles; medium Grey colour; size -1200 x 600mm_20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To kids pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Internal floor finish; type SP-02-A; R11 structured; non - slip ribbed porcelain tiles; medium Grey colour; size -1200 x 600mm_20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To kids pool",
          "quantity": 78,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 27300,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1081
          },
          "extra_columns": {
            "GF & Podium [D]": "78",
            "TOTAL QTY [I]": "78",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/16-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Wall coping; type SP-02-C; honed granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To kids pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Wall coping; type SP-02-C; honed granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To kids pool",
          "quantity": 97,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 29100,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1085
          },
          "extra_columns": {
            "GF & Podium [D]": "97",
            "TOTAL QTY [I]": "97",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "29,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/16-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Polysoft material; type PD-03-C; beige mix colour; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works; as per Specialist Design"
          ],
          "own_description": "To kids splash pad",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Polysoft material; type PD-03-C; beige mix colour; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works; as per Specialist Design — To kids splash pad",
          "quantity": 82,
          "unit": "m2",
          "rate_aed": 950,
          "amount_aed": 77900,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1089
          },
          "extra_columns": {
            "GF & Podium [D]": "82",
            "TOTAL QTY [I]": "82",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "77,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/16-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse internal floor finish; type SP-03-A; R11 structured non-slip porcelain tile; medium grey colour; size -1200 x 600mm_20mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse internal floor finish; type SP-03-A; R11 structured non-slip porcelain tile; medium grey colour; size -1200 x 600mm_20mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool",
          "quantity": 274,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 95900,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1093
          },
          "extra_columns": {
            "Tower 1 [E]": "66",
            "Tower 2 [F]": "71",
            "Tower 3 [G]": "66",
            "Tower 4 [H]": "71",
            "TOTAL QTY [I]": "274",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "23,100.00",
            "TOWER 2 [P]": "24,850.00",
            "TOWER 3 [Q]": "23,100.00",
            "TOWER 4 [R]": "24,850.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/16-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse internal floor finish; type SP-03-B; R11 structured non-slip porcelain tile; sandshell colour; size -1200 x 600mm_20mm 9mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse internal floor finish; type SP-03-B; R11 structured non-slip porcelain tile; sandshell colour; size -1200 x 600mm_20mm 9mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool",
          "quantity": 174,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 60900,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1097
          },
          "extra_columns": {
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "43",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "43",
            "TOTAL QTY [I]": "174",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "15,400.00",
            "TOWER 2 [P]": "15,050.00",
            "TOWER 3 [Q]": "15,400.00",
            "TOWER 4 [R]": "15,050.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/16-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse infinity edge coping; type SP-03-C; R11 structured non-slip porcelain tile; medium grey colour; size 600 x 400mm_100mm 9mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse infinity edge coping; type SP-03-C; R11 structured non-slip porcelain tile; medium grey colour; size 600 x 400mm_100mm 9mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool",
          "quantity": 180,
          "unit": "m2",
          "rate_aed": 140,
          "amount_aed": 25200,
          "amount_state": "number",
          "printed_page": "3/J/4",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1101
          },
          "extra_columns": {
            "Tower 1 [E]": "44",
            "Tower 2 [F]": "46",
            "Tower 3 [G]": "44",
            "Tower 4 [H]": "46",
            "TOTAL QTY [I]": "180",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,160.00",
            "TOWER 2 [P]": "6,440.00",
            "TOWER 3 [Q]": "6,160.00",
            "TOWER 4 [R]": "6,440.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/17",
      "section": "FLOOR FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 128582,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/17-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse wall coping; type SP-03-D; R11; cleft limestone; beige colour; granite; honed; absolute black; size 600 x 320mm_50mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse wall coping; type SP-03-D; R11; cleft limestone; beige colour; granite; honed; absolute black; size 600 x 320mm_50mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool",
          "quantity": 96,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 28800,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1122
          },
          "extra_columns": {
            "Tower 1 [E]": "23",
            "Tower 2 [F]": "25",
            "Tower 3 [G]": "23",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "96",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,900.00",
            "TOWER 2 [P]": "7,500.00",
            "TOWER 3 [Q]": "6,900.00",
            "TOWER 4 [R]": "7,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-B",
          "item_code": "B",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse infinity edge coping; type SP-03-E; R11 cleft limestone; light beige colour; structured non-slip porcelain tile; medium grey; size 600 x 400mm_100mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool - 400mm",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse infinity edge coping; type SP-03-E; R11 cleft limestone; light beige colour; structured non-slip porcelain tile; medium grey; size 600 x 400mm_100mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool - 400mm",
          "quantity": 56,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 16800,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1126
          },
          "extra_columns": {
            "Tower 1 [E]": "14",
            "Tower 2 [F]": "14",
            "Tower 3 [G]": "14",
            "Tower 4 [H]": "14",
            "TOTAL QTY [I]": "56",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "4,200.00",
            "TOWER 2 [P]": "4,200.00",
            "TOWER 3 [Q]": "4,200.00",
            "TOWER 4 [R]": "4,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-C",
          "item_code": "C",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse infinity edge coping; type SP-03-E; R11 cleft limestone; light beige colour; structured non-slip porcelain tile; medium grey; size 600 x 400mm_100mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool - 240mm",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse infinity edge coping; type SP-03-E; R11 cleft limestone; light beige colour; structured non-slip porcelain tile; medium grey; size 600 x 400mm_100mm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool - 240mm",
          "quantity": 34,
          "unit": "m",
          "rate_aed": 108,
          "amount_aed": 3672,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1128
          },
          "extra_columns": {
            "Tower 2 [F]": "17",
            "Tower 4 [H]": "17",
            "TOTAL QTY [I]": "34",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "1,836.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "1,836.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-D",
          "item_code": "D",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Penthouse internal floor finish; type SP-03-G SP-01-G; pool step marker - homed omani limestone; light beige-grey colour; size 300 x 30mm_9mmm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pool - 100mm",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Penthouse internal floor finish; type SP-03-G SP-01-G; pool step marker - homed omani limestone; light beige-grey colour; size 300 x 30mm_9mmm with a 3mm joint with sealant;  laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pool - 100mm",
          "quantity": 124,
          "unit": "m2",
          "rate_aed": 450,
          "amount_aed": 55800,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1132
          },
          "extra_columns": {
            "Tower 1 [E]": "28",
            "Tower 2 [F]": "34",
            "Tower 3 [G]": "28",
            "Tower 4 [H]": "34",
            "TOTAL QTY [I]": "124",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,600.00",
            "TOWER 2 [P]": "15,300.00",
            "TOWER 3 [Q]": "12,600.00",
            "TOWER 4 [R]": "15,300.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-E",
          "item_code": "E",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Internal floor finish; type WF-01-A; honed granite tile; absolute black colour; size 400 x 400mm_9mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To water feature",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Internal floor finish; type WF-01-A; honed granite tile; absolute black colour; size 400 x 400mm_9mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To water feature",
          "quantity": 16,
          "unit": "m2",
          "rate_aed": 800,
          "amount_aed": 12800,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1136
          },
          "extra_columns": {
            "Tower 2 [F]": "8",
            "Tower 4 [H]": "8",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-F",
          "item_code": "F",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Wall coping; type WF-01-C; honed granite tile; absolute black colour; size 400 x 360mm_50mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To water feature",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Wall coping; type WF-01-C; honed granite tile; absolute black colour; size 400 x 360mm_50mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To water feature",
          "quantity": 54,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 6480,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1140
          },
          "extra_columns": {
            "GF & Podium [D]": "54",
            "TOTAL QTY [I]": "54",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-G",
          "item_code": "G",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Wall coping; type WF-01-C; honed granite tile; absolute black colour; size 400 x 360mm_30mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To water feature",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Wall coping; type WF-01-C; honed granite tile; absolute black colour; size 400 x 360mm_30mm with a 3mm jointlaid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To water feature",
          "quantity": 27,
          "unit": "m",
          "rate_aed": 120,
          "amount_aed": 3240,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1144
          },
          "extra_columns": {
            "GF & Podium [D]": "27",
            "TOTAL QTY [I]": "27",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/17-H",
          "item_code": "H",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Drop-off Area; Type WF-01-D; 20-40mm river washed dark grey mix pebbles"
          ],
          "own_description": "To water feature; 150mm thick",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Drop-off Area; Type WF-01-D; 20-40mm river washed dark grey mix pebbles — To water feature; 150mm thick",
          "quantity": 3,
          "unit": "m",
          "rate_aed": 330,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "3/J/5",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1148
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/18",
      "section": "WALL FINISHES",
      "sheet": "3 - Ext",
      "source_collection_aed": 445300,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/18-A",
          "item_code": "A",
          "section": "FLOOR FINISHES",
          "heading_path": [
            "Internal floor finish; type WF-02-A; honed granite tile; absolute black colour; size 1200 x 600mm_9mm 20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To water feature",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — FLOOR FINISHES — Internal floor finish; type WF-02-A; honed granite tile; absolute black colour; size 1200 x 600mm_9mm 20mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To water feature",
          "quantity": 197,
          "unit": "m2",
          "rate_aed": 800,
          "amount_aed": 157600,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1166
          },
          "extra_columns": {
            "GF & Podium [D]": "171",
            "Tower 2 [F]": "13",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "197",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "136,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "10,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "10,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-B",
          "item_code": "B",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 190mm high",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 190mm high",
          "quantity": 31,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 10850,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1172
          },
          "extra_columns": {
            "GF & Podium [D]": "27",
            "Tower 2 [F]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "31",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "700.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-C",
          "item_code": "C",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 420mm high",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 420mm high",
          "quantity": 39,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 13650,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1174
          },
          "extra_columns": {
            "GF & Podium [D]": "39",
            "TOTAL QTY [I]": "39",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-D",
          "item_code": "D",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 450mm high",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 450mm high",
          "quantity": 23,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 8050,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1176
          },
          "extra_columns": {
            "GF & Podium [D]": "23",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,050.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-E",
          "item_code": "E",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 2290mm high shower",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 2290mm high shower",
          "quantity": 94,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 32900,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1178
          },
          "extra_columns": {
            "GF & Podium [D]": "94",
            "TOTAL QTY [I]": "94",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-F",
          "item_code": "F",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 2410mm high",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium cladding tile; type PD-02-C; R10 structured non - slip porcelain tiles; light beige colour; 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 2410mm high",
          "quantity": 4,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 1400,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1180
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-G",
          "item_code": "G",
          "section": "WALL FINISHES",
          "heading_path": [
            "Podium wall tile; type PD-02-1; R11 structured non - slip ribbed; porcelain tiles; warm grey colour; 600 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To shower",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Podium wall tile; type PD-02-1; R11 structured non - slip ribbed; porcelain tiles; warm grey colour; 600 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To shower",
          "quantity": 98,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 34300,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1184
          },
          "extra_columns": {
            "GF & Podium [D]": "98",
            "TOTAL QTY [I]": "98",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "34,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-H",
          "item_code": "H",
          "section": "WALL FINISHES",
          "heading_path": [
            "Internal wall finish; type SP-01-B; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pools",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Internal wall finish; type SP-01-B; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pools",
          "quantity": 501,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 175350,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1188
          },
          "extra_columns": {
            "GF & Podium [D]": "501",
            "TOTAL QTY [I]": "501",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "175,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/18-J",
          "item_code": "J",
          "section": "WALL FINISHES",
          "heading_path": [
            "Internal wall finish; type SP-01-B; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To water features",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Internal wall finish; type SP-01-B; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To water features",
          "quantity": 32,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 11200,
          "amount_state": "number",
          "printed_page": "3/J/6",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1190
          },
          "extra_columns": {
            "GF & Podium [D]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/19",
      "section": "SIGNWRITING",
      "sheet": "3 - Ext",
      "source_collection_aed": 181838,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/19-A",
          "item_code": "A",
          "section": "WALL FINISHES",
          "heading_path": [
            "Infinity edge cladding; type SP-01-C; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pools",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Infinity edge cladding; type SP-01-C; R11 structured non - slip porcelain tiles; medium grey colour; size 1200 x 600 x 20mm; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pools",
          "quantity": 212,
          "unit": "m2",
          "rate_aed": 350,
          "amount_aed": 74200,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1215
          },
          "extra_columns": {
            "GF & Podium [D]": "212",
            "TOTAL QTY [I]": "212",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "74,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-B",
          "item_code": "B",
          "section": "WALL FINISHES",
          "heading_path": [
            "Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 260mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 260mm width",
          "quantity": 130,
          "unit": "m",
          "rate_aed": 220,
          "amount_aed": 28600,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1219
          },
          "extra_columns": {
            "GF & Podium [D]": "130",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-C",
          "item_code": "C",
          "section": "WALL FINISHES",
          "heading_path": [
            "Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 290mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 290mm width",
          "quantity": 20,
          "unit": "m",
          "rate_aed": 246,
          "amount_aed": 4920,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1221
          },
          "extra_columns": {
            "GF & Podium [D]": "20",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,920.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-D",
          "item_code": "D",
          "section": "WALL FINISHES",
          "heading_path": [
            "Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 300mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 300mm width",
          "quantity": 25,
          "unit": "m",
          "rate_aed": 254,
          "amount_aed": 6350,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1223
          },
          "extra_columns": {
            "GF & Podium [D]": "25",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,350.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-E",
          "item_code": "E",
          "section": "WALL FINISHES",
          "heading_path": [
            "Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "Size 320mm width",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Pool wall coping; type SP-01-D; R11 shoned granite tiles; absolute black colour; size - 600 x 320mm_50mm with a 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — Size 320mm width",
          "quantity": 198,
          "unit": "m",
          "rate_aed": 271,
          "amount_aed": 53658,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1225
          },
          "extra_columns": {
            "GF & Podium [D]": "198",
            "TOTAL QTY [I]": "198",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "53,658.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-F",
          "item_code": "F",
          "section": "WALL FINISHES",
          "heading_path": [
            "Infinity edge coping; type SP-01-E; R11 structured non - slip porcelain tiles; medium grey colour; light beige; size 600 x 400_9mm 20mm thick; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works."
          ],
          "own_description": "To swimming pools",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — WALL FINISHES — Infinity edge coping; type SP-01-E; R11 structured non - slip porcelain tiles; medium grey colour; light beige; size 600 x 400_9mm 20mm thick; with 3mm joint; laid on cement sand screed (measured separately); including grouting, joints, dry set mortar or adhesive and all necessary ancillary works. — To swimming pools",
          "quantity": 74,
          "unit": "m",
          "rate_aed": 140,
          "amount_aed": 10360,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1229
          },
          "extra_columns": {
            "GF & Podium [D]": "74",
            "TOTAL QTY [I]": "74",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-G",
          "item_code": "G",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Straight arrow; type 614",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Straight arrow; type 614",
          "quantity": 23,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 2300,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1236
          },
          "extra_columns": {
            "GF & Podium [D]": "23",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-H",
          "item_code": "H",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Right turn arrow; type 615",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Right turn arrow; type 615",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1238
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-J",
          "item_code": "J",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Left turn arrow; type 616",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Left turn arrow; type 616",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1240
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-K",
          "item_code": "K",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Left and right arrow",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Left and right arrow",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 100,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1242
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/19-L",
          "item_code": "L",
          "section": "SIGNWRITING",
          "heading_path": [
            "Floor markings; including finishes, accessories and all ancillary works as necessary"
          ],
          "own_description": "Hatch area",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — SIGNWRITING — Floor markings; including finishes, accessories and all ancillary works as necessary — Hatch area",
          "quantity": 230,
          "unit": "m2",
          "rate_aed": 5,
          "amount_aed": 1150,
          "amount_state": "number",
          "printed_page": "3/J/7",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1244
          },
          "extra_columns": {
            "GF & Podium [D]": "230",
            "TOTAL QTY [I]": "230",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/20",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/20-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Finishes in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION J - FINISHES (3/J) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Finishes in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/J/8",
          "bill_ref": "3",
          "section_ref": "3/J",
          "source": {
            "sheet": "3 - Ext",
            "row": 1264
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/21",
      "section": "ROADS",
      "sheet": "3 - Ext",
      "source_collection_aed": 173500,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/21-A",
          "item_code": "A",
          "section": "SHOWER",
          "heading_path": [
            "Outdoor pool shower; 'GESSI' shower product series; matte black colour; including all necessary fixing and ancillary works"
          ],
          "own_description": "To lap pool shower area",
          "full_description": "Bill 3 — SECTION K - ACCESSORIES (3/K) — SHOWER — Outdoor pool shower; 'GESSI' shower product series; matte black colour; including all necessary fixing and ancillary works — To lap pool shower area",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 17650,
          "amount_aed": 105900,
          "amount_state": "number",
          "printed_page": "3/K/1",
          "bill_ref": "3",
          "section_ref": "3/K",
          "source": {
            "sheet": "3 - Ext",
            "row": 1393
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "105,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/21-B",
          "item_code": "B",
          "section": "SHOWER",
          "heading_path": [
            "Outdoor pool shower; 'GESSI' shower product series; matte black colour; including all necessary fixing and ancillary works"
          ],
          "own_description": "To kids pool shower area",
          "full_description": "Bill 3 — SECTION K - ACCESSORIES (3/K) — SHOWER — Outdoor pool shower; 'GESSI' shower product series; matte black colour; including all necessary fixing and ancillary works — To kids pool shower area",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 17650,
          "amount_aed": 35300,
          "amount_state": "number",
          "printed_page": "3/K/1",
          "bill_ref": "3",
          "section_ref": "3/K",
          "source": {
            "sheet": "3 - Ext",
            "row": 1395
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "35,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/21-C",
          "item_code": "C",
          "section": "ROADS",
          "heading_path": [
            "Supply and install road studs; including all necessary fixing and ancillary works"
          ],
          "own_description": "Road studs",
          "full_description": "Bill 3 — SECTION K - ACCESSORIES (3/K) — ROADS — Supply and install road studs; including all necessary fixing and ancillary works — Road studs",
          "quantity": 323,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 32300,
          "amount_state": "number",
          "printed_page": "3/K/1",
          "bill_ref": "3",
          "section_ref": "3/K",
          "source": {
            "sheet": "3 - Ext",
            "row": 1401
          },
          "extra_columns": {
            "GF & Podium [D]": "323",
            "TOTAL QTY [I]": "323",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/22",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/22-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Accessories in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION K - ACCESSORIES (3/K) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Accessories in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/K/2",
          "bill_ref": "3",
          "section_ref": "3/K",
          "source": {
            "sheet": "3 - Ext",
            "row": 1452
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/23",
      "section": "EQUIPMENT",
      "sheet": "3 - Ext",
      "source_collection_aed": 2205000,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/23-A",
          "item_code": "A",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Play Area"
          ],
          "own_description": "Type DP-01; wobble dish",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Play Area — Type DP-01; wobble dish",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1581
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-B",
          "item_code": "B",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Play Area"
          ],
          "own_description": "Type DP-02; jumping disc",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Play Area — Type DP-02; jumping disc",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 180000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1583
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "180,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-C",
          "item_code": "C",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Play Area"
          ],
          "own_description": "Type DP-03; EPDM two-tone mound",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Play Area — Type DP-03; EPDM two-tone mound",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 75000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1585
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "75,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-D",
          "item_code": "D",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Play Area"
          ],
          "own_description": "Type DP-04; in-ground bouncers (trampoline)",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Play Area — Type DP-04; in-ground bouncers (trampoline)",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 45000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1587
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-E",
          "item_code": "E",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Splash Pad"
          ],
          "own_description": "Type WP-01; archimedes-screws",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Splash Pad — Type WP-01; archimedes-screws",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1591
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-F",
          "item_code": "F",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Splash Pad"
          ],
          "own_description": "Type WP-01; flower nozzles",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Splash Pad — Type WP-01; flower nozzles",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 800000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1593
          },
          "extra_columns": {
            "GF & Podium [D]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-G",
          "item_code": "G",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Splash Pad"
          ],
          "own_description": "Type WP-03; mushroom pump / spring",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Splash Pad — Type WP-03; mushroom pump / spring",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 175000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1595
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "175,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-H",
          "item_code": "H",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Splash Pad"
          ],
          "own_description": "Type WP-04; scooping wheel-water-scoop",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Splash Pad — Type WP-04; scooping wheel-water-scoop",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 50000,
          "amount_aed": 100000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1597
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-J",
          "item_code": "J",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "Splash Pad"
          ],
          "own_description": "Type WP-05; foot bubblers",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — Splash Pad — Type WP-05; foot bubblers",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 25000,
          "amount_aed": 475000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1599
          },
          "extra_columns": {
            "GF & Podium [D]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "475,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/23-K",
          "item_code": "K",
          "section": "EQUIPMENT",
          "heading_path": [
            "Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary",
            "BBQ Station"
          ],
          "own_description": "BBQ Station - 2035X750X900mm- Silver Aztecs - Christie Modular Series Triple Barbecue Cabinet From Supplier - Mod-E-3.2:Sink(Electric)",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — EQUIPMENT — Play equipment; supply, delivery and installation; including fittings, accessories and all ancillary works as necessary — BBQ Station — BBQ Station - 2035X750X900mm- Silver Aztecs - Christie Modular Series Triple Barbecue Cabinet From Supplier - Mod-E-3.2:Sink(Electric)",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 35000,
          "amount_aed": 315000,
          "amount_state": "number",
          "printed_page": "3/L/1",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1603
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "315,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/24",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/24-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Equipment in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION L - EQUIPMENT (3/L) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Equipment in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/L/2",
          "bill_ref": "3",
          "section_ref": "3/L",
          "source": {
            "sheet": "3 - Ext",
            "row": 1639
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/25",
      "section": "SHADE STRUCTURE",
      "sheet": "3 - Ext",
      "source_collection_aed": 4054050,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/25-A",
          "item_code": "A",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Bench; type FE-01-B finished with Omani limestone with a Honed finish; light beige - Grey colour; 15140 x 740mm ( as per drawing ZD-3250587-MLD-DWG-PDM-LAN-2110_D)",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Bench; type FE-01-B finished with Omani limestone with a Honed finish; light beige - Grey colour; 15140 x 740mm ( as per drawing ZD-3250587-MLD-DWG-PDM-LAN-2110_D)",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 56018,
          "amount_aed": 280090,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1768
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "280,090.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-B",
          "item_code": "B",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Lounge table",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Lounge table",
          "quantity": 65,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1770
          },
          "extra_columns": {
            "GF & Podium [D]": "65",
            "TOTAL QTY [I]": "65",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-C",
          "item_code": "C",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Outdoor chaise",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Outdoor chaise",
          "quantity": 130,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1772
          },
          "extra_columns": {
            "GF & Podium [D]": "130",
            "TOTAL QTY [I]": "130",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-D",
          "item_code": "D",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Pool umbrella",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Pool umbrella",
          "quantity": 42,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1774
          },
          "extra_columns": {
            "GF & Podium [D]": "42",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-E",
          "item_code": "E",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Lifeguard station",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Lifeguard station",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1776
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-F",
          "item_code": "F",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Raised cabana",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Raised cabana",
          "quantity": 35,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1778
          },
          "extra_columns": {
            "GF & Podium [D]": "35",
            "TOTAL QTY [I]": "35",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-G",
          "item_code": "G",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Code: FE-02-G; Waste and recycling aluminium bins; size  775 x 260 dia x 985mm high",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Code: FE-02-G; Waste and recycling aluminium bins; size  775 x 260 dia x 985mm high",
          "quantity": 11,
          "unit": "Nr.",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1780
          },
          "extra_columns": {
            "GF & Podium [D]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-H",
          "item_code": "H",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Supply and installation of site furniture; including necessary fixings and all other associated works"
          ],
          "own_description": "Contractor to allow for co-ordination, attendance and builders work. Supply and installation of loose site furniture (any item that is loosely kept and does not require a concrete\r\nfoundation or mechanical fixing) by Others.",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Supply and installation of site furniture; including necessary fixings and all other associated works — Contractor to allow for co-ordination, attendance and builders work. Supply and installation of loose site furniture (any item that is loosely kept and does not require a concrete\r\nfoundation or mechanical fixing) by Others.",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": 65000,
          "amount_aed": 65000,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1782
          },
          "extra_columns": {
            "GF & Podium [D]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "65,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-J",
          "item_code": "J",
          "section": "SITE FURNITURE",
          "heading_path": [
            "Tree pots; GRC pots; with soil mix; including all necessary ancillary works"
          ],
          "own_description": "900mm diameter",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SITE FURNITURE — Tree pots; GRC pots; with soil mix; including all necessary ancillary works — 900mm diameter",
          "quantity": 44,
          "unit": "Nr.",
          "rate_aed": 7350,
          "amount_aed": 323400,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1786
          },
          "extra_columns": {
            "GF & Podium [D]": "44",
            "TOTAL QTY [I]": "44",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "323,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-K",
          "item_code": "K",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 1A: BBQ Pods; size 4500 x 4000 x 3250mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 1A: BBQ Pods; size 4500 x 4000 x 3250mm H",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 93600,
          "amount_aed": 842400,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1792
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "842,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-L",
          "item_code": "L",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 1A: Yoga Pavilion; size 9720 x 8620mm x 3160mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 1A: Yoga Pavilion; size 9720 x 8620mm x 3160mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 423630,
          "amount_aed": 423630,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1794
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "423,630.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-M",
          "item_code": "M",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 1B: Kids Play; size 14900 x 9945 x 3250mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 1B: Kids Play; size 14900 x 9945 x 3250mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 770540,
          "amount_aed": 770540,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1796
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "770,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-N",
          "item_code": "N",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 1B: Kids Pool-01; size 12490 x 7820mm x 3250mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 1B: Kids Pool-01; size 12490 x 7820mm x 3250mm H",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 507900,
          "amount_aed": 1015800,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1798
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,015,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-P",
          "item_code": "P",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 1B: Kids Pool-05; size 4630 x 11200 x 3200mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 1B: Kids Pool-05; size 4630 x 11200 x 3200mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 265510,
          "amount_aed": 265510,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1800
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "265,510.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/25-Q",
          "item_code": "Q",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 2A: Pool 01 & 04 Double; size 3000 x 5875mm x 2400mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 2A: Pool 01 & 04 Double; size 3000 x 5875mm x 2400mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 67680,
          "amount_aed": 67680,
          "amount_state": "number",
          "printed_page": "3/M/1",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1802
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "67,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/26",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 3245910,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/26-A",
          "item_code": "A",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 2A: Pool 01 & 04 Single; size  3000 x 3000 x 2400mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 2A: Pool 01 & 04 Single; size  3000 x 3000 x 2400mm H",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 34560,
          "amount_aed": 449280,
          "amount_state": "number",
          "printed_page": "3/M/2",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1820
          },
          "extra_columns": {
            "GF & Podium [D]": "13",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "449,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/26-B",
          "item_code": "B",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 2B: Pool 02; size 3000 x 2400 x 2400mm H with sheer fabric",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 2B: Pool 02; size 3000 x 2400 x 2400mm H with sheer fabric",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 34560,
          "amount_aed": 691200,
          "amount_state": "number",
          "printed_page": "3/M/2",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1822
          },
          "extra_columns": {
            "GF & Podium [D]": "20",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "691,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/26-C",
          "item_code": "C",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 3: (Open Pavilion) Communal Pavilion; size 12420 x 3000 x 3050mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 3: (Open Pavilion) Communal Pavilion; size 12420 x 3000 x 3050mm H",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 181830,
          "amount_aed": 363660,
          "amount_state": "number",
          "printed_page": "3/M/2",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1824
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "363,660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/26-D",
          "item_code": "D",
          "section": "SHADE STRUCTURE",
          "heading_path": [
            "Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works"
          ],
          "own_description": "Type 3: (Open Pavilion) Kids Pool 3; size 25985 x 12695 x 3300mm H",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — SHADE STRUCTURE — Shade structure; powder coated Jotun 0406 Champagne colour aluminium - custom size to specialists detail and design (See concept on sheet 6803) - fixing to slab TBC by Structural Engineer; including necessary fixings and all other associated works — Type 3: (Open Pavilion) Kids Pool 3; size 25985 x 12695 x 3300mm H",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1741770,
          "amount_aed": 1741770,
          "amount_state": "number",
          "printed_page": "3/M/2",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1826
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,741,770.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/26-E",
          "item_code": "E",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Furnishing in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION M - FURNISHING (3/M) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Furnishing in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/M/2",
          "bill_ref": "3",
          "section_ref": "3/M",
          "source": {
            "sheet": "3 - Ext",
            "row": 1831
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/27",
      "section": "SWIMMING POOL",
      "sheet": "3 - Ext",
      "source_collection_aed": 598170,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/27-A",
          "item_code": "A",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "450mm dia Sand filter  to swimming pool 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 450mm dia Sand filter  to swimming pool 03",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 2970,
          "amount_aed": 5940,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1944
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-B",
          "item_code": "B",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "500mm dia Sand filter",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 500mm dia Sand filter",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 3300.0000000000005,
          "amount_aed": 26400.000000000004,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1946
          },
          "extra_columns": {
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "6,600.00",
            "TOWER 2 [P]": "6,600.00",
            "TOWER 3 [Q]": "6,600.00",
            "TOWER 4 [R]": "6,600.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-C",
          "item_code": "C",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "550mm dia Sand filter to swimming pool 04 & 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 550mm dia Sand filter to swimming pool 04 & 05",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4235,
          "amount_aed": 16940,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1948
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,940.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-D",
          "item_code": "D",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "1000mm dia Sand filter to swimming pool 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 1000mm dia Sand filter to swimming pool 02",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 12650.000000000002,
          "amount_aed": 25300.000000000004,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1950
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "25,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-E",
          "item_code": "E",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "1200mm dia Sand filter to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 1200mm dia Sand filter to swimming pool 01 + kids pool",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 13750.000000000002,
          "amount_aed": 27500.000000000004,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1952
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-F",
          "item_code": "F",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 0.75 HP (2D + 1S)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 0.75 HP (2D + 1S)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 65600,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1954
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,400.00",
            "TOWER 2 [P]": "16,400.00",
            "TOWER 3 [Q]": "16,400.00",
            "TOWER 4 [R]": "16,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-G",
          "item_code": "G",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 1 Hp/Ph (2D + 1S)  to swimming pool 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 1 Hp/Ph (2D + 1S)  to swimming pool 03",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 32800,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1956
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-H",
          "item_code": "H",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 1.5 Hp/1Ph (2D + 1S) to swimming pool 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 1.5 Hp/1Ph (2D + 1S) to swimming pool 05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 16400,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1958
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-J",
          "item_code": "J",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 3Hp / 3Ph (2D + 1S) to swimming pool 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 3Hp / 3Ph (2D + 1S) to swimming pool 02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 16400,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1960
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-K",
          "item_code": "K",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 3.5 Hp/3Ph  to swimming pool 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 3.5 Hp/3Ph  to swimming pool 04",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5450,
          "amount_aed": 5450,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1962
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-L",
          "item_code": "L",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 5.5Hp / 3Ph (2D + 1S) to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 5.5Hp / 3Ph (2D + 1S) to swimming pool 01 + kids pool",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 16400,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1964
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-M",
          "item_code": "M",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Small Tank to swimming pool 02, 03, 04 & 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Small Tank to swimming pool 02, 03, 04 & 05",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 31680,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1966
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,680.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-N",
          "item_code": "N",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Big Tank  to swimming pool 03 & 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Big Tank  to swimming pool 03 & 04",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 12320.000000000002,
          "amount_aed": 49280.00000000001,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1968
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "49,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-P",
          "item_code": "P",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Balancing tank 10m3  to swimming pool 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Balancing tank 10m3  to swimming pool 04",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 37300,
          "amount_aed": 37300,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1970
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "37,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-Q",
          "item_code": "Q",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Balancing tank (2m x 3m  x 2m) to swimming pool 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Balancing tank (2m x 3m  x 2m) to swimming pool 05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 44800,
          "amount_aed": 44800,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1972
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "44,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-R",
          "item_code": "R",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Balancing tank (4m x 2m  x 2m)  to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Balancing tank (4m x 2m  x 2m)  to swimming pool 01 + kids pool",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 59700,
          "amount_aed": 59700,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1974
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "59,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-S",
          "item_code": "S",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "UV Disinfection System to swimming pool 01, 02, 03, 04 & 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — UV Disinfection System to swimming pool 01, 02, 03, 04 & 05",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 100000,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1976
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "100,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-T",
          "item_code": "T",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank 100 Ltr including stirrer to swimming pool 03 & penthouse pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank 100 Ltr including stirrer to swimming pool 03 & penthouse pool",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1978
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/27-U",
          "item_code": "U",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank 200 Ltr, flow 80 m3/hr including manual mixer to swimming pool 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank 200 Ltr, flow 80 m3/hr including manual mixer to swimming pool 02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 5280,
          "amount_state": "number",
          "printed_page": "3/N/1",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 1980
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/28",
      "section": "SWIMMING POOL",
      "sheet": "3 - Ext",
      "source_collection_aed": 1229669,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/28-A",
          "item_code": "A",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank 250 Ltr, flow 112 m3/hr including manual mixer to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank 250 Ltr, flow 112 m3/hr including manual mixer to swimming pool 01 + kids pool",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6600,
          "amount_aed": 6600,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2000
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-B",
          "item_code": "B",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank 200 ltr, flow 20 m3/hr including manual mixer swimming pool 04 & 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank 200 ltr, flow 20 m3/hr including manual mixer swimming pool 04 & 05",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 10560,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2002
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-C",
          "item_code": "C",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Automatic chemical dosing system for swimming pool 01, 02, 03, 04 & 05 and penthouse pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Automatic chemical dosing system for swimming pool 01, 02, 03, 04 & 05 and penthouse pool",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2250,
          "amount_aed": 20250,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2004
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,250.00",
            "TOWER 1 [O]": "2,250.00",
            "TOWER 2 [P]": "2,250.00",
            "TOWER 3 [Q]": "2,250.00",
            "TOWER 4 [R]": "2,250.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-D",
          "item_code": "D",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 100 Ltr including stirrer to swimming pool 03 & penthouse pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 100 Ltr including stirrer to swimming pool 03 & penthouse pool",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2006
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "3,000.00",
            "TOWER 2 [P]": "3,000.00",
            "TOWER 3 [Q]": "3,000.00",
            "TOWER 4 [R]": "3,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-E",
          "item_code": "E",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 200 ltr, flow 20 m3/hr including stirrer to swimming pool 04 & 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 200 ltr, flow 20 m3/hr including stirrer to swimming pool 04 & 05",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 10560,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2008
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-F",
          "item_code": "F",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 200 Ltr, flow 80 m3/hr including stirrer to swimming pool 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 200 Ltr, flow 80 m3/hr including stirrer to swimming pool 02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 5280,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2010
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-G",
          "item_code": "G",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 250 Ltr, flow 112 m3/hr including stirrer to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 250 Ltr, flow 112 m3/hr including stirrer to swimming pool 01 + kids pool",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2012
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-H",
          "item_code": "H",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat cool pump, heating/cooling capacity 35kW/25kW to swimming pool 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat cool pump, heating/cooling capacity 35kW/25kW to swimming pool 03",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 24368,
          "amount_aed": 24368,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2014
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "24,368.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-J",
          "item_code": "J",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat cool pump, heating/cooling capacity 45kW/32kW to swimming pool 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat cool pump, heating/cooling capacity 45kW/32kW to swimming pool 05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 31330,
          "amount_aed": 31330,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2016
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-K",
          "item_code": "K",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat cool pump, heating/cooling capacity 160kW/115kW to swimming pool 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat cool pump, heating/cooling capacity 160kW/115kW to swimming pool 04",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 111395,
          "amount_aed": 111395,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2018
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "111,395.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-L",
          "item_code": "L",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat cool pump, heating/cooling capacity 250kW/180kW to swimming pool 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat cool pump, heating/cooling capacity 250kW/180kW to swimming pool 02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 174055,
          "amount_aed": 174055,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2020
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "174,055.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-M",
          "item_code": "M",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat cool pump, heating/cooling capacity 135kW/97kW to swimming pool 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat cool pump, heating/cooling capacity 135kW/97kW to swimming pool 01 + kids pool",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 93990,
          "amount_aed": 187980,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2022
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "187,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-N",
          "item_code": "N",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Water meter to swimming pool 01, 02, 03, 04 & 05 and penthouse pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Water meter to swimming pool 01, 02, 03, 04 & 05 and penthouse pool",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 10800,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2024
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "1,200.00",
            "TOWER 2 [P]": "1,200.00",
            "TOWER 3 [Q]": "1,200.00",
            "TOWER 4 [R]": "1,200.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-P",
          "item_code": "P",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Electrical heater 60kW",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Electrical heater 60kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 16700,
          "amount_aed": 66800,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2026
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "16,700.00",
            "TOWER 2 [P]": "16,700.00",
            "TOWER 3 [Q]": "16,700.00",
            "TOWER 4 [R]": "16,700.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-Q",
          "item_code": "Q",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Heat Exchanger, capacity: 40kW",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Heat Exchanger, capacity: 40kW",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 129000,
          "amount_aed": 516000,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2028
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "129,000.00",
            "TOWER 2 [P]": "129,000.00",
            "TOWER 3 [Q]": "129,000.00",
            "TOWER 4 [R]": "129,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-R",
          "item_code": "R",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Pressure breaking chamber (600 x 800 x 600mm)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Pressure breaking chamber (600 x 800 x 600mm)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 30000,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2030
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,500.00",
            "TOWER 2 [P]": "7,500.00",
            "TOWER 3 [Q]": "7,500.00",
            "TOWER 4 [R]": "7,500.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-S",
          "item_code": "S",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "25mm (1 inch) Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 25mm (1 inch) Ball valve",
          "quantity": 25,
          "unit": "Nr.",
          "rate_aed": 39,
          "amount_aed": 975,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2034
          },
          "extra_columns": {
            "GF & Podium [D]": "11",
            "Tower 1 [E]": "5",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "5",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "25",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "429.00",
            "TOWER 1 [O]": "195.00",
            "TOWER 2 [P]": "78.00",
            "TOWER 3 [Q]": "195.00",
            "TOWER 4 [R]": "78.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/28-T",
          "item_code": "T",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "40mm (1 1/2 inch) Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 40mm (1 1/2 inch) Ball valve",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 66,
          "amount_aed": 1716,
          "amount_state": "number",
          "printed_page": "3/N/2",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2036
          },
          "extra_columns": {
            "GF & Podium [D]": "26",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,716.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/29",
      "section": "SWIMMING POOL",
      "sheet": "3 - Ext",
      "source_collection_aed": 90915,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/29-A",
          "item_code": "A",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\") Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 50mm (2\") Ball valve",
          "quantity": 80,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 7040,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2055
          },
          "extra_columns": {
            "GF & Podium [D]": "26",
            "Tower 1 [E]": "12",
            "Tower 2 [F]": "15",
            "Tower 3 [G]": "12",
            "Tower 4 [H]": "15",
            "TOTAL QTY [I]": "80",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,288.00",
            "TOWER 1 [O]": "1,056.00",
            "TOWER 2 [P]": "1,320.00",
            "TOWER 3 [Q]": "1,056.00",
            "TOWER 4 [R]": "1,320.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-B",
          "item_code": "B",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "60mm (2 1/2 inch) Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 60mm (2 1/2 inch) Ball valve",
          "quantity": 22,
          "unit": "Nr.",
          "rate_aed": 333,
          "amount_aed": 7326,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2057
          },
          "extra_columns": {
            "Tower 1 [E]": "7",
            "Tower 2 [F]": "4",
            "Tower 3 [G]": "7",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "2,331.00",
            "TOWER 2 [P]": "1,332.00",
            "TOWER 3 [Q]": "2,331.00",
            "TOWER 4 [R]": "1,332.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-C",
          "item_code": "C",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "75mm (3 inch) ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 75mm (3 inch) ball valve",
          "quantity": 20,
          "unit": "Nr.",
          "rate_aed": 578,
          "amount_aed": 11560,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2059
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "20",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,312.00",
            "TOWER 1 [O]": "1,156.00",
            "TOWER 2 [P]": "3,468.00",
            "TOWER 3 [Q]": "1,156.00",
            "TOWER 4 [R]": "3,468.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-D",
          "item_code": "D",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "80mm (3\") Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 80mm (3\") Ball valve",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 578,
          "amount_aed": 5780,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2061
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-E",
          "item_code": "E",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "100mm (4\") Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 100mm (4\") Ball valve",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 823,
          "amount_aed": 1646,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2063
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,646.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-F",
          "item_code": "F",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "25mm (1 inch) NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 25mm (1 inch) NRV",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2065
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "80.00",
            "TOWER 1 [O]": "80.00",
            "TOWER 2 [P]": "240.00",
            "TOWER 3 [Q]": "80.00",
            "TOWER 4 [R]": "240.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-G",
          "item_code": "G",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "40mm (2\") NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 40mm (2\") NRV",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 99.00000000000001,
          "amount_aed": 99.00000000000001,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2067
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "99.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-H",
          "item_code": "H",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\") NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 50mm (2\") NRV",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 99.00000000000001,
          "amount_aed": 891.0000000000001,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2069
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "297.00",
            "TOWER 1 [O]": "198.00",
            "TOWER 2 [P]": "99.00",
            "TOWER 3 [Q]": "198.00",
            "TOWER 4 [R]": "99.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-J",
          "item_code": "J",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "60mm (2 1/2 inch) NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 60mm (2 1/2 inch) NRV",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 201,
          "amount_aed": 2412,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2071
          },
          "extra_columns": {
            "Tower 1 [E]": "3",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "3",
            "Tower 4 [H]": "3",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "603.00",
            "TOWER 2 [P]": "603.00",
            "TOWER 3 [Q]": "603.00",
            "TOWER 4 [R]": "603.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-K",
          "item_code": "K",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "75mm (3 inch) NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 75mm (3 inch) NRV",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 303,
          "amount_aed": 606,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2073
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "606.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-L",
          "item_code": "L",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "80mm (3\") NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 80mm (3\") NRV",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 303,
          "amount_aed": 1818,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2075
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,818.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-M",
          "item_code": "M",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "100mm (4\") NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 100mm (4\") NRV",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 507,
          "amount_aed": 507,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2077
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "507.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-N",
          "item_code": "N",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "150mm (6\") NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 150mm (6\") NRV",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 915,
          "amount_aed": 5490,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2079
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,490.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-P",
          "item_code": "P",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "25mm (1 inch) Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 25mm (1 inch) Butterfly valve",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 65,
          "amount_aed": 520,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2081
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-Q",
          "item_code": "Q",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 50mm (2\") Butterfly valve",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 616,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2083
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "616.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-R",
          "item_code": "R",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "63mm (2 1/2\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 63mm (2 1/2\") Butterfly valve",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 333,
          "amount_aed": 1998,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2085
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,998.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-S",
          "item_code": "S",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "75mm (2\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 75mm (2\") Butterfly valve",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 333,
          "amount_aed": 2997,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2087
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,997.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-T",
          "item_code": "T",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "80mm (3\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 80mm (3\") Butterfly valve",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 578,
          "amount_aed": 5780,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2089
          },
          "extra_columns": {
            "GF & Podium [D]": "10",
            "TOTAL QTY [I]": "10",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,780.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-U",
          "item_code": "U",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "100mm (4\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 100mm (4\") Butterfly valve",
          "quantity": 18,
          "unit": "Nr.",
          "rate_aed": 655,
          "amount_aed": 11790,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2091
          },
          "extra_columns": {
            "GF & Podium [D]": "18",
            "TOTAL QTY [I]": "18",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,790.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-V",
          "item_code": "V",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "150mm (6\") Butterfly valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 150mm (6\") Butterfly valve",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 1100,
          "amount_aed": 17600,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2093
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-W",
          "item_code": "W",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\") solenoid valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 50mm (2\") solenoid valve",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 719,
          "amount_aed": 719,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2095
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "719.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-X",
          "item_code": "X",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Pipe Accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2 inch) Bypass valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Pipe Accessories complete with all ancillary work as necessary — 50mm (2 inch) Bypass valve",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 550,
          "amount_aed": 2200,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2097
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "550.00",
            "TOWER 2 [P]": "550.00",
            "TOWER 3 [Q]": "550.00",
            "TOWER 4 [R]": "550.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-Y",
          "item_code": "Y",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "60mm (2 1/2 inch) discharge header, flow 22m3/hr",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 60mm (2 1/2 inch) discharge header, flow 22m3/hr",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 240,
          "amount_aed": 480,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2101
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 3 [G]": "1",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "240.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "240.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/29-Z",
          "item_code": "Z",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "75mm (3 inch) discharge header, flow 16 m3/hr to SP 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 75mm (3 inch) discharge header, flow 16 m3/hr to SP 03",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "3/N/3",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2103
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/30",
      "section": "SWIMMING POOL",
      "sheet": "3 - Ext",
      "source_collection_aed": 213577,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/30-A",
          "item_code": "A",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "80mm (3\") fabricated discharge header, flow 20m3/hr to SP 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 80mm (3\") fabricated discharge header, flow 20m3/hr to SP 04",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2118
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-B",
          "item_code": "B",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "80mm (3\") Discharge header, flow 20m3/hr to SP 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 80mm (3\") Discharge header, flow 20m3/hr to SP 05",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2120
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-C",
          "item_code": "C",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "150mm (6\") fabricated discharge header, flow 112 m3/hr to SP 01 + kids pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 150mm (6\") fabricated discharge header, flow 112 m3/hr to SP 01 + kids pool",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2122
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-D",
          "item_code": "D",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "150mm (6\") fabricated discharge header, flow 80m3/hr to SP 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 150mm (6\") fabricated discharge header, flow 80m3/hr to SP 02",
          "quantity": 1,
          "unit": "",
          "rate_aed": 600,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2124
          },
          "extra_columns": {
            "GF & Podium [D]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-E",
          "item_code": "E",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "7\" Suction header, flow 20m3/hr  to SP 04",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 7\" Suction header, flow 20m3/hr  to SP 04",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 700,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2126
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-F",
          "item_code": "F",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "80mm (3\") Suction header, flow 20m3/hr to SP 05",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 80mm (3\") Suction header, flow 20m3/hr to SP 05",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 960,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2128
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "Tower 1 [E]": "1",
            "Tower 3 [G]": "1",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "320.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "320.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-G",
          "item_code": "G",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "150mm (6\") fabricated suction header, flow 80m3/hr to SP 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 150mm (6\") fabricated suction header, flow 80m3/hr to SP 02",
          "quantity": 1,
          "unit": "",
          "rate_aed": 600,
          "amount_aed": 600,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2130
          },
          "extra_columns": {
            "GF & Podium [D]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-H",
          "item_code": "H",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "200 x 200mm frame and grate anti-vortex drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 200 x 200mm frame and grate anti-vortex drain",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 1155,
          "amount_aed": 17325,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2132
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,085.00",
            "TOWER 1 [O]": "2,310.00",
            "TOWER 2 [P]": "2,310.00",
            "TOWER 3 [Q]": "2,310.00",
            "TOWER 4 [R]": "2,310.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-J",
          "item_code": "J",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "300 x 300mm frame and grate anti-vortex drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — 300 x 300mm frame and grate anti-vortex drain",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1595.0000000000002,
          "amount_aed": 12760.000000000002,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2134
          },
          "extra_columns": {
            "GF & Podium [D]": "8",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-K",
          "item_code": "K",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Acid injection point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Acid injection point",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 2310,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2136
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "1",
            "Tower 3 [G]": "1",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,650.00",
            "TOWER 1 [O]": "330.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "330.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-L",
          "item_code": "L",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine injection point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Chlorine injection point",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 2310,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2138
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "Tower 1 [E]": "1",
            "Tower 3 [G]": "1",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,650.00",
            "TOWER 1 [O]": "330.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "330.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-M",
          "item_code": "M",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Drain fittings",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Drain fittings",
          "quantity": 13,
          "unit": "Nr.",
          "rate_aed": 110.00000000000001,
          "amount_aed": 1430.0000000000002,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2140
          },
          "extra_columns": {
            "GF & Podium [D]": "13",
            "TOTAL QTY [I]": "13",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,430.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-N",
          "item_code": "N",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Main drain point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Main drain point",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 660,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2142
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-P",
          "item_code": "P",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Floor Drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Floor Drain",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 110.00000000000001,
          "amount_aed": 440.00000000000006,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2144
          },
          "extra_columns": {
            "Tower 1 [E]": "2",
            "Tower 3 [G]": "2",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "220.00",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "220.00",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-Q",
          "item_code": "Q",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration inlet (wall)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Filtration inlet (wall)",
          "quantity": 83,
          "unit": "Nr.",
          "rate_aed": 572,
          "amount_aed": 47476,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2146
          },
          "extra_columns": {
            "GF & Podium [D]": "59",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "6",
            "Tower 3 [G]": "6",
            "Tower 4 [H]": "6",
            "TOTAL QTY [I]": "83",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,748.00",
            "TOWER 1 [O]": "3,432.00",
            "TOWER 2 [P]": "3,432.00",
            "TOWER 3 [Q]": "3,432.00",
            "TOWER 4 [R]": "3,432.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-R",
          "item_code": "R",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Skimmer",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Skimmer",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 2300,
          "amount_aed": 59800,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2148
          },
          "extra_columns": {
            "GF & Podium [D]": "26",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "59,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-S",
          "item_code": "S",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Vacuum point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Vacuum point",
          "quantity": 23,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 7590,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2150
          },
          "extra_columns": {
            "GF & Podium [D]": "15",
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "23",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,950.00",
            "TOWER 1 [O]": "660.00",
            "TOWER 2 [P]": "660.00",
            "TOWER 3 [Q]": "660.00",
            "TOWER 4 [R]": "660.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-T",
          "item_code": "T",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Wire inlet fitting (wall)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Wire inlet fitting (wall)",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 572,
          "amount_aed": 1144,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2152
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,144.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-U",
          "item_code": "U",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Wall inlet",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Wall inlet",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 572,
          "amount_aed": 3432,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2154
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,432.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-V",
          "item_code": "V",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Overflow fitting",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Overflow fitting",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 3200,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2156
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-W",
          "item_code": "W",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Overflow drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Overflow drain",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 1600,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2158
          },
          "extra_columns": {
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "400.00",
            "TOWER 2 [P]": "400.00",
            "TOWER 3 [Q]": "400.00",
            "TOWER 4 [R]": "400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-X",
          "item_code": "X",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Water level regulator",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Water level regulator",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 20000,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2160
          },
          "extra_columns": {
            "Tower 1 [E]": "1",
            "Tower 2 [F]": "1",
            "Tower 3 [G]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "5,000.00",
            "TOWER 2 [P]": "5,000.00",
            "TOWER 3 [Q]": "5,000.00",
            "TOWER 4 [R]": "5,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/30-Y",
          "item_code": "Y",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Infinity channel drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Swimming pool accessories complete, fittings, all hangers, supports and ancillary work as necessary — Infinity channel drain",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 28000,
          "amount_state": "number",
          "printed_page": "3/N/4",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2162
          },
          "extra_columns": {
            "Tower 1 [E]": "2",
            "Tower 2 [F]": "2",
            "Tower 3 [G]": "2",
            "Tower 4 [H]": "2",
            "TOTAL QTY [I]": "8",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "7,000.00",
            "TOWER 2 [P]": "7,000.00",
            "TOWER 3 [Q]": "7,000.00",
            "TOWER 4 [R]": "7,000.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/31",
      "section": "SWIMMING POOL",
      "sheet": "3 - Ext",
      "source_collection_aed": 564921,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/31-A",
          "item_code": "A",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 1 + Kids Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 1 + Kids Pool",
          "quantity": 290,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 76560,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2182
          },
          "extra_columns": {
            "GF & Podium [D]": "290",
            "TOTAL QTY [I]": "290",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "76,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-B",
          "item_code": "B",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 2",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 2",
          "quantity": 414,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 109296,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2184
          },
          "extra_columns": {
            "GF & Podium [D]": "414",
            "TOTAL QTY [I]": "414",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "109,296.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-C",
          "item_code": "C",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 3 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 3 (Kids Pool)",
          "quantity": 48,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 12672,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2186
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,672.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-D",
          "item_code": "D",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 4",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 4",
          "quantity": 179,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 47256,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2188
          },
          "extra_columns": {
            "GF & Podium [D]": "179",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "47,256.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-E",
          "item_code": "E",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 5 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 5 (Kids Pool)",
          "quantity": 64,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 16896,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2190
          },
          "extra_columns": {
            "GF & Podium [D]": "64",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,896.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-F",
          "item_code": "F",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Penthouse Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Allow for Swimming pool water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Penthouse Pool",
          "quantity": 286,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 75504,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2192
          },
          "extra_columns": {
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "286",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,480.00",
            "TOWER 2 [P]": "19,272.00",
            "TOWER 3 [Q]": "18,480.00",
            "TOWER 4 [R]": "19,272.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-G",
          "item_code": "G",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 1 + Kids Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 1 + Kids Pool",
          "quantity": 290,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 51330,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2198
          },
          "extra_columns": {
            "GF & Podium [D]": "290",
            "TOTAL QTY [I]": "290",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-H",
          "item_code": "H",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 2",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 2",
          "quantity": 414,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 73278,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2200
          },
          "extra_columns": {
            "GF & Podium [D]": "414",
            "TOTAL QTY [I]": "414",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "73,278.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-J",
          "item_code": "J",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 3 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 3 (Kids Pool)",
          "quantity": 48,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 8496,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2202
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,496.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-K",
          "item_code": "K",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 4",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 4",
          "quantity": 179,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 31683,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2204
          },
          "extra_columns": {
            "GF & Podium [D]": "179",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,683.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-L",
          "item_code": "L",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 5 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 5 (Kids Pool)",
          "quantity": 64,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 11328,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2206
          },
          "extra_columns": {
            "GF & Podium [D]": "64",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,328.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/31-M",
          "item_code": "M",
          "section": "SWIMMING POOL",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Penthouse Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — SWIMMING POOL — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Penthouse Pool",
          "quantity": 286,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 50622,
          "amount_state": "number",
          "printed_page": "3/N/5",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2208
          },
          "extra_columns": {
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "286",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,390.00",
            "TOWER 2 [P]": "12,921.00",
            "TOWER 3 [Q]": "12,390.00",
            "TOWER 4 [R]": "12,921.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/32",
      "section": "WATER FEATURES",
      "sheet": "3 - Ext",
      "source_collection_aed": 283099,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/32-A",
          "item_code": "A",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "450mm dia Sand filter to WF 02, 03, PH",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 450mm dia Sand filter to WF 02, 03, PH",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 2970,
          "amount_aed": 17820,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2242
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "Tower 2 [F]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,880.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,970.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "2,970.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-B",
          "item_code": "B",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "550mm dia Sand filter to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — 550mm dia Sand filter to WF 01",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3300.0000000000005,
          "amount_aed": 6600.000000000001,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2244
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-C",
          "item_code": "C",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Small tank to WF 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Small tank to WF 02, 03",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 21120,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2246
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,120.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-D",
          "item_code": "D",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank - 100 Ltr, flow 10m3/hr  including manual mixer to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank - 100 Ltr, flow 10m3/hr  including manual mixer to WF 01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2248
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-E",
          "item_code": "E",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Acid tank - 100 Ltr, flow 16m3/hr  including manual mixer to  WF 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Acid tank - 100 Ltr, flow 16m3/hr  including manual mixer to  WF 02, 03",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2250
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-F",
          "item_code": "F",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Automatic chemical dosing system to WF 01, 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Automatic chemical dosing system to WF 01, 02, 03",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 8800,
          "amount_aed": 26400,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2252
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-G",
          "item_code": "G",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "UV disinfection system to WF 02, 03, PH",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — UV disinfection system to WF 02, 03, PH",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 20000,
          "amount_aed": 80000,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2254
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 2 [F]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "20,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "20,000.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-H",
          "item_code": "H",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 100 Ltr, flow 10m3/hr including stirrer to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 100 Ltr, flow 10m3/hr including stirrer to WF 01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2256
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-J",
          "item_code": "J",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine tank 100 Ltr, flow 16m3/hr including stirrer to WF 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Chlorine tank 100 Ltr, flow 16m3/hr including stirrer to WF 02, 03",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5280,
          "amount_aed": 10560,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2258
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-K",
          "item_code": "K",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 1Hp /1 Ph (2D + 1S) for WF-01 to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 1Hp /1 Ph (2D + 1S) for WF-01 to WF 01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 16400,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2260
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-L",
          "item_code": "L",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration pump 1.5Hp/1 Ph (2D + 1S) to WF 02, 03, PH",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Filtration pump 1.5Hp/1 Ph (2D + 1S) to WF 02, 03, PH",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 16400,
          "amount_aed": 65600,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2262
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "Tower 2 [F]": "1",
            "Tower 4 [H]": "1",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "32,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "16,400.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "16,400.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-M",
          "item_code": "M",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Water meter to WF 01, 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature equipment complete, fittings, including all hangers, electrical connection, supports and ancillary work as necessary — Water meter to WF 01, 02, 03",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2264
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-N",
          "item_code": "N",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "25mm (1 inch) Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 25mm (1 inch) Ball valve",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 39,
          "amount_aed": 234,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2268
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "234.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-P",
          "item_code": "P",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "40mm (1 1/2\") Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 40mm (1 1/2\") Ball valve",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 66,
          "amount_aed": 924,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2270
          },
          "extra_columns": {
            "GF & Podium [D]": "14",
            "TOTAL QTY [I]": "14",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "924.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-Q",
          "item_code": "Q",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\" ) Ball valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 50mm (2\" ) Ball valve",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 88,
          "amount_aed": 2464,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2272
          },
          "extra_columns": {
            "GF & Podium [D]": "28",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,464.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-R",
          "item_code": "R",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "80mm (3\") Ball Valve",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 80mm (3\") Ball Valve",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 578,
          "amount_aed": 3468,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2274
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,468.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-S",
          "item_code": "S",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "50mm (2\" ) NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 50mm (2\" ) NRV",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 99,
          "amount_aed": 891,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2276
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "891.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-T",
          "item_code": "T",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "80mm (3\" ) NRV",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — 80mm (3\" ) NRV",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 303,
          "amount_aed": 1818,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2278
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,818.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/32-U",
          "item_code": "U",
          "section": "WATER FEATURES",
          "heading_path": [
            "Pipe accessories complete with all ancillary work as necessary"
          ],
          "own_description": "Allow for pipe accessories for penthouse water feature",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Pipe accessories complete with all ancillary work as necessary — Allow for pipe accessories for penthouse water feature",
          "quantity": 50,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "3/N/6",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2280
          },
          "extra_columns": {
            "Tower 2 [F]": "25",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,600.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/33",
      "section": "WATER FEATURES",
      "sheet": "3 - Ext",
      "source_collection_aed": 514707,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/33-A",
          "item_code": "A",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "50mm (2\" ) discharge header, flow 10m3/hr to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 50mm (2\" ) discharge header, flow 10m3/hr to WF 01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2300
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-B",
          "item_code": "B",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "80mm (3\") discharge header, flow 16m3/hr to WF 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 80mm (3\") discharge header, flow 16m3/hr to WF 02, 03",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 640,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2302
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "640.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-C",
          "item_code": "C",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "50mm (2\") suction header, flow 10m3/hr to WF 01",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 50mm (2\") suction header, flow 10m3/hr to WF 01",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2304
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-D",
          "item_code": "D",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "50mm (3\") suction header, flow 16m3/hr to WF 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 50mm (3\") suction header, flow 16m3/hr to WF 03",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 200,
          "amount_aed": 200,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2306
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-E",
          "item_code": "E",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "80mm (3\") suction header, flow 16m3/hr to WF 02",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 80mm (3\") suction header, flow 16m3/hr to WF 02",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 320,
          "amount_aed": 320,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2308
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "320.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-F",
          "item_code": "F",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "200x200mm frame & grate anti-vortex drain to WF 01, 02, 03",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — 200x200mm frame & grate anti-vortex drain to WF 01, 02, 03",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 1155,
          "amount_aed": 8085,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2310
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,085.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-G",
          "item_code": "G",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Floor Drain",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Floor Drain",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 110.00000000000001,
          "amount_aed": 770.0000000000001,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2312
          },
          "extra_columns": {
            "GF & Podium [D]": "7",
            "TOTAL QTY [I]": "7",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "770.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-H",
          "item_code": "H",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Filtration inlet (wall)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Filtration inlet (wall)",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 572,
          "amount_aed": 14872,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2314
          },
          "extra_columns": {
            "GF & Podium [D]": "26",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "14,872.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-J",
          "item_code": "J",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Skimmer fitting",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Skimmer fitting",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2300,
          "amount_aed": 27600,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2316
          },
          "extra_columns": {
            "GF & Podium [D]": "12",
            "TOTAL QTY [I]": "12",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-K",
          "item_code": "K",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Vacuum point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Vacuum point",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 1980,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2318
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,980.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-L",
          "item_code": "L",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Acid injection point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Acid injection point",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 990,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2320
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "990.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-M",
          "item_code": "M",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Chlorine injection point",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Chlorine injection point",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 330,
          "amount_aed": 660,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2322
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "660.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-N",
          "item_code": "N",
          "section": "WATER FEATURES",
          "heading_path": [
            "Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary"
          ],
          "own_description": "Allow for water feature accessories for penthouse water feature",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Water feature accessories complete, fittings, all hangers, supports and ancillary work as necessary — Allow for water feature accessories for penthouse water feature",
          "quantity": 50,
          "unit": "m2",
          "rate_aed": 531,
          "amount_aed": 26550,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2324
          },
          "extra_columns": {
            "Tower 2 [F]": "25",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "13,275.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "13,275.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-P",
          "item_code": "P",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 1 + Kids Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 1 + Kids Pool",
          "quantity": 290,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 76560,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2328
          },
          "extra_columns": {
            "GF & Podium [D]": "290",
            "TOTAL QTY [I]": "290",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "76,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-Q",
          "item_code": "Q",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 2",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 2",
          "quantity": 414,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 109296,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2330
          },
          "extra_columns": {
            "GF & Podium [D]": "414",
            "TOTAL QTY [I]": "414",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "109,296.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-R",
          "item_code": "R",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 3 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 3 (Kids Pool)",
          "quantity": 48,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 12672,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2332
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,672.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-S",
          "item_code": "S",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 4",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 4",
          "quantity": 179,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 47256,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2334
          },
          "extra_columns": {
            "GF & Podium [D]": "179",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "47,256.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-T",
          "item_code": "T",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Swimming Pool 5 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Swimming Pool 5 (Kids Pool)",
          "quantity": 64,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 16896,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2336
          },
          "extra_columns": {
            "GF & Podium [D]": "64",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,896.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-U",
          "item_code": "U",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Penthouse Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Penthouse Pool",
          "quantity": 286,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 75504,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2338
          },
          "extra_columns": {
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "286",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "18,480.00",
            "TOWER 2 [P]": "19,272.00",
            "TOWER 3 [Q]": "18,480.00",
            "TOWER 4 [R]": "19,272.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-V",
          "item_code": "V",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water Feature 01 at Ground Floor",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Water Feature 01 at Ground Floor",
          "quantity": 51,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 13464,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2340
          },
          "extra_columns": {
            "GF & Podium [D]": "51",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "13,464.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-W",
          "item_code": "W",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water Feature 02 at Podium",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Water Feature 02 at Podium",
          "quantity": 99,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 26136,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2342
          },
          "extra_columns": {
            "GF & Podium [D]": "99",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "26,136.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-X",
          "item_code": "X",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Water Feature 03 at Podium",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Water Feature 03 at Podium",
          "quantity": 154,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 40656,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2344
          },
          "extra_columns": {
            "GF & Podium [D]": "154",
            "TOTAL QTY [I]": "154",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,656.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/33-Y",
          "item_code": "Y",
          "section": "WATER FEATURES",
          "heading_path": [
            "Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary"
          ],
          "own_description": "Penthouse water feature",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Allow for water supply and drainage system including pipes, fittings, fixings, accessories and all ancillary works as necessary — Penthouse water feature",
          "quantity": 50,
          "unit": "m2",
          "rate_aed": 264,
          "amount_aed": 13200,
          "amount_state": "number",
          "printed_page": "3/N/7",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2346
          },
          "extra_columns": {
            "Tower 2 [F]": "25",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "6,600.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "6,600.00",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/34",
      "section": "LIGHTING INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 799020,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/34-A",
          "item_code": "A",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 1 + Kids Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 1 + Kids Pool",
          "quantity": 290,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 51330,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2367
          },
          "extra_columns": {
            "GF & Podium [D]": "290",
            "TOTAL QTY [I]": "290",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-B",
          "item_code": "B",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 2",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 2",
          "quantity": 414,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 73278,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2369
          },
          "extra_columns": {
            "GF & Podium [D]": "414",
            "TOTAL QTY [I]": "414",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "73,278.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-C",
          "item_code": "C",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 3 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 3 (Kids Pool)",
          "quantity": 48,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 8496,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2371
          },
          "extra_columns": {
            "GF & Podium [D]": "48",
            "TOTAL QTY [I]": "48",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "8,496.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-D",
          "item_code": "D",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 4",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 4",
          "quantity": 179,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 31683,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2373
          },
          "extra_columns": {
            "GF & Podium [D]": "179",
            "TOTAL QTY [I]": "179",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,683.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-E",
          "item_code": "E",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Swimming Pool 5 (Kids Pool)",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Swimming Pool 5 (Kids Pool)",
          "quantity": 64,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 11328,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2375
          },
          "extra_columns": {
            "GF & Podium [D]": "64",
            "TOTAL QTY [I]": "64",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,328.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-F",
          "item_code": "F",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Penthouse Pool",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Penthouse Pool",
          "quantity": 286,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 50622,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2377
          },
          "extra_columns": {
            "Tower 1 [E]": "70",
            "Tower 2 [F]": "73",
            "Tower 3 [G]": "70",
            "Tower 4 [H]": "73",
            "TOTAL QTY [I]": "286",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "12,390.00",
            "TOWER 2 [P]": "12,921.00",
            "TOWER 3 [Q]": "12,390.00",
            "TOWER 4 [R]": "12,921.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-G",
          "item_code": "G",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Water Feature 01 at Ground Floor",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Water Feature 01 at Ground Floor",
          "quantity": 51,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 9027,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2379
          },
          "extra_columns": {
            "GF & Podium [D]": "51",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,027.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-H",
          "item_code": "H",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Water Feature 02 at Podium",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Water Feature 02 at Podium",
          "quantity": 99,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 17523,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2381
          },
          "extra_columns": {
            "GF & Podium [D]": "99",
            "TOTAL QTY [I]": "99",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,523.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-J",
          "item_code": "J",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Water Feature 03 at Podium",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Water Feature 03 at Podium",
          "quantity": 154,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 27258,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2383
          },
          "extra_columns": {
            "GF & Podium [D]": "154",
            "TOTAL QTY [I]": "154",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "27,258.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-K",
          "item_code": "K",
          "section": "WATER FEATURES",
          "heading_path": [
            "Electrical Installation",
            "Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary."
          ],
          "own_description": "Penthouse water feature",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — WATER FEATURES — Electrical Installation — Allow for Electrical works including distribution board, control panel, cables, conduits, terminations, fixings, supports, accessories, control panels and all works as necessary. — Penthouse water feature",
          "quantity": 50,
          "unit": "m2",
          "rate_aed": 177,
          "amount_aed": 8850,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2385
          },
          "extra_columns": {
            "Tower 2 [F]": "25",
            "Tower 4 [H]": "25",
            "TOTAL QTY [I]": "50",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "4,425.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "4,425.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Final sub-circuits and ancillary installations complete; including cabling, wiring, containment and terminations as necessary"
          ],
          "own_description": "Light points",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — LIGHTING INSTALLATION — Final sub-circuits and ancillary installations complete; including cabling, wiring, containment and terminations as necessary — Light points",
          "quantity": 171,
          "unit": "Nr.",
          "rate_aed": 275,
          "amount_aed": 47025,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2391
          },
          "extra_columns": {
            "GF & Podium [D]": "114",
            "Tower 1 [E]": "13",
            "Tower 2 [F]": "18",
            "Tower 3 [G]": "13",
            "Tower 4 [H]": "13",
            "TOTAL QTY [I]": "171",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "31,350.00",
            "TOWER 1 [O]": "3,575.00",
            "TOWER 2 [P]": "4,950.00",
            "TOWER 3 [Q]": "3,575.00",
            "TOWER 4 [R]": "3,575.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 4.1; Recessed elliptical beam pool light; 3000 K",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 4.1; Recessed elliptical beam pool light; 3000 K",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 2640,
          "amount_aed": 129360,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2395
          },
          "extra_columns": {
            "GF & Podium [D]": "34",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "Tower 3 [G]": "4",
            "Tower 4 [H]": "4",
            "TOTAL QTY [I]": "49",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "89,760.00",
            "TOWER 1 [O]": "10,560.00",
            "TOWER 2 [P]": "7,920.00",
            "TOWER 3 [Q]": "10,560.00",
            "TOWER 4 [R]": "10,560.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-N",
          "item_code": "N",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 4.2; Recessed elliptical beam pool step light; 3000 K",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 4.2; Recessed elliptical beam pool step light; 3000 K",
          "quantity": 91,
          "unit": "Nr.",
          "rate_aed": 2640,
          "amount_aed": 240240,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2397
          },
          "extra_columns": {
            "GF & Podium [D]": "49",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "15",
            "Tower 3 [G]": "9",
            "Tower 4 [H]": "9",
            "TOTAL QTY [I]": "91",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "129,360.00",
            "TOWER 1 [O]": "23,760.00",
            "TOWER 2 [P]": "39,600.00",
            "TOWER 3 [Q]": "23,760.00",
            "TOWER 4 [R]": "23,760.00",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-P",
          "item_code": "P",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 4.3; Recessed diffused pool marker light; 4000K",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 4.3; Recessed diffused pool marker light; 4000K",
          "quantity": 15,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 45000,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2399
          },
          "extra_columns": {
            "GF & Podium [D]": "15",
            "TOTAL QTY [I]": "15",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/34-Q",
          "item_code": "Q",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 8.2; Surface mounted floor washer; 3000 K",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 8.2; Surface mounted floor washer; 3000 K",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 48000,
          "amount_state": "number",
          "printed_page": "3/N/8",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2401
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "48,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/35",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/35-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Special Construction in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION N - SPECIAL CONSTRUCTION (3/N) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Special Construction in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/N/9",
          "bill_ref": "3",
          "section_ref": "3/N",
          "source": {
            "sheet": "3 - Ext",
            "row": 2421
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/36",
      "section": "DRAINAGE INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 18570,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/36-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "110mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — 110mm dia",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2520,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2551
          },
          "extra_columns": {
            "GF & Podium [D]": "42",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "160mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — 160mm dia",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2553
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "250mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — 250mm dia",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 3300,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2555
          },
          "extra_columns": {
            "GF & Podium [D]": "22",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — 300mm dia",
          "quantity": 4,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2557
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "110mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Sand bed and surround to pipes — 110mm dia",
          "quantity": 42,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2520,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2561
          },
          "extra_columns": {
            "GF & Podium [D]": "42",
            "TOTAL QTY [I]": "42",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,520.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "160mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Sand bed and surround to pipes — 160mm dia",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2563
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "250mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Sand bed and surround to pipes — 250mm dia",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 3300,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2565
          },
          "extra_columns": {
            "GF & Podium [D]": "22",
            "TOTAL QTY [I]": "22",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Sand bed and surround to pipes — 300mm dia",
          "quantity": 4,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 720,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2567
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "720.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Soil Pipework"
          ],
          "own_description": "110mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Soil Pipework — 110mm dia",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 60,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2573
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Soil Pipework"
          ],
          "own_description": "160mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Soil Pipework — 160mm dia",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 90,
          "amount_aed": 450,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2575
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Soil Pipework"
          ],
          "own_description": "250mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Soil Pipework — 250mm dia",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 1650,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2577
          },
          "extra_columns": {
            "GF & Podium [D]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Soil Pipework"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Soil Pipework — 300mm dia",
          "quantity": 2,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2579
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-N",
          "item_code": "N",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Waste Pipework"
          ],
          "own_description": "110mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Waste Pipework — 110mm dia",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 60,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2583
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-P",
          "item_code": "P",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Waste Pipework"
          ],
          "own_description": "250mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Waste Pipework — 250mm dia",
          "quantity": 11,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 1650,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2585
          },
          "extra_columns": {
            "GF & Podium [D]": "11",
            "TOTAL QTY [I]": "11",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,650.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/36-Q",
          "item_code": "Q",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Waste Pipework"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Waste Pipework — 300mm dia",
          "quantity": 2,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 360,
          "amount_state": "number",
          "printed_page": "3/Q/1",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2587
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/37",
      "section": "POTABLE WATER INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 190130,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/37-A",
          "item_code": "A",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Parking Drain Pipework"
          ],
          "own_description": "110mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Parking Drain Pipework — 110mm dia",
          "quantity": 40,
          "unit": "m",
          "rate_aed": 60,
          "amount_aed": 2400,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2611
          },
          "extra_columns": {
            "GF & Podium [D]": "40",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-B",
          "item_code": "B",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Perforated drain pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)"
          ],
          "own_description": "Perforated drain pipe",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Perforated drain pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Perforated drain pipe",
          "quantity": 161,
          "unit": "m",
          "rate_aed": 70,
          "amount_aed": 11270,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2615
          },
          "extra_columns": {
            "GF & Podium [D]": "161",
            "TOTAL QTY [I]": "161",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "11,270.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-C",
          "item_code": "C",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories, including supports, excavation, disposal and ancillary work as necessary"
          ],
          "own_description": "Linear slot drain inlet",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Accessories, including supports, excavation, disposal and ancillary work as necessary — Linear slot drain inlet",
          "quantity": 275,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 82500,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2619
          },
          "extra_columns": {
            "GF & Podium [D]": "275",
            "TOTAL QTY [I]": "275",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "82,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-D",
          "item_code": "D",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories, including supports, excavation, disposal and ancillary work as necessary"
          ],
          "own_description": "Trench drain inlet",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Accessories, including supports, excavation, disposal and ancillary work as necessary — Trench drain inlet",
          "quantity": 1,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2621
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-E",
          "item_code": "E",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories, including supports, excavation, disposal and ancillary work as necessary"
          ],
          "own_description": "Point drain",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Accessories, including supports, excavation, disposal and ancillary work as necessary — Point drain",
          "quantity": 26,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 7800,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2623
          },
          "extra_columns": {
            "GF & Podium [D]": "26",
            "TOTAL QTY [I]": "26",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-F",
          "item_code": "F",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Accessories, including supports, excavation, disposal and ancillary work as necessary"
          ],
          "own_description": "Fullbore position",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Accessories, including supports, excavation, disposal and ancillary work as necessary — Fullbore position",
          "quantity": 100,
          "unit": "Nr.",
          "rate_aed": 100,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2625
          },
          "extra_columns": {
            "GF & Podium [D]": "100",
            "TOTAL QTY [I]": "100",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-G",
          "item_code": "G",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Gully trap complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size."
          ],
          "own_description": "Gully Trap",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Gully trap complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size. — Gully Trap",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 2500,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2629
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-H",
          "item_code": "H",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size."
          ],
          "own_description": "MH01-1500mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size. — MH01-1500mm dia",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 15000,
          "amount_aed": 15000,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2633
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "15,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-J",
          "item_code": "J",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size."
          ],
          "own_description": "MH02-1500mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size. — MH02-1500mm dia",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 16500,
          "amount_aed": 16500,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2635
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-K",
          "item_code": "K",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size."
          ],
          "own_description": "MH03-1500mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement\r\nand formwork complete as specified of the following size. — MH03-1500mm dia",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 18000,
          "amount_aed": 18000,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2637
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-L",
          "item_code": "L",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pressure Break Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement and formwork complete as specified of the following size."
          ],
          "own_description": "Pressure Breaking Manhole (PBM) 600x600mm",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Pressure Break Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement and formwork complete as specified of the following size. — Pressure Breaking Manhole (PBM) 600x600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10500,
          "amount_aed": 10500,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2641
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-M",
          "item_code": "M",
          "section": "DRAINAGE INSTALLATION",
          "heading_path": [
            "Pressure Break Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement and formwork complete as specified of the following size."
          ],
          "own_description": "Pressure Breaking Manhole (PBM) 800x600mm",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — DRAINAGE INSTALLATION — Pressure Break Manhole complete; cover, all necessary excavation, disposal, backfilling, reinforcement and formwork complete as specified of the following size. — Pressure Breaking Manhole (PBM) 800x600mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 12000,
          "amount_aed": 12000,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2643
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/37-N",
          "item_code": "N",
          "section": "POTABLE WATER INSTALLATION",
          "heading_path": [
            "Potable water supply; including pipes, fittings, accessories, excavation, backfill, beds and surrounds, foundations and all ancillary works as necessary"
          ],
          "own_description": "To bib tap",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — POTABLE WATER INSTALLATION — Potable water supply; including pipes, fittings, accessories, excavation, backfill, beds and surrounds, foundations and all ancillary works as necessary — To bib tap",
          "quantity": 17,
          "unit": "Nr.",
          "rate_aed": 80,
          "amount_aed": 1360,
          "amount_state": "number",
          "printed_page": "3/Q/2",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2649
          },
          "extra_columns": {
            "GF & Podium [D]": "17",
            "TOTAL QTY [I]": "17",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,360.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/38",
      "section": "FIRE FIGHTING INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 252440,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/38-A",
          "item_code": "A",
          "section": "SEWER INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SEWER INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — 300mm dia",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2662
          },
          "extra_columns": {
            "GF & Podium [D]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/38-B",
          "item_code": "B",
          "section": "SEWER INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SEWER INSTALLATION — Sand bed and surround to pipes — 300mm dia",
          "quantity": 32,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 5760,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2666
          },
          "extra_columns": {
            "GF & Podium [D]": "32",
            "TOTAL QTY [I]": "32",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,760.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/38-C",
          "item_code": "C",
          "section": "SEWER INSTALLATION",
          "heading_path": [
            "uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere)",
            "Sewer Pipework"
          ],
          "own_description": "300mm dia",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SEWER INSTALLATION — uPVC Pipes and fittings; including pipe supports, connections, thrust blocks, accessories and all ancillary works as necessary; laid in trenches (measured elsewhere) — Sewer Pipework — 300mm dia",
          "quantity": 29,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 5220,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2672
          },
          "extra_columns": {
            "GF & Podium [D]": "29",
            "TOTAL QTY [I]": "29",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,220.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/38-D",
          "item_code": "D",
          "section": "SEWER INSTALLATION",
          "heading_path": [
            "Waste/sewer connection for WC, urinal and wash basin at gatehouse/security room (by others); including pipes, fittings, accessories, excavation, backfill, beds and surrounds, foundations and all ancillary works as necessary"
          ],
          "own_description": "Waste connection",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SEWER INSTALLATION — Waste/sewer connection for WC, urinal and wash basin at gatehouse/security room (by others); including pipes, fittings, accessories, excavation, backfill, beds and surrounds, foundations and all ancillary works as necessary — Waste connection",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 45000,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2676
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "45,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/38-E",
          "item_code": "E",
          "section": "SEWER INSTALLATION",
          "heading_path": [
            "Tie-in Connection"
          ],
          "own_description": "Tie-in connection to existing 300mm dia sewer pipe",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SEWER INSTALLATION — Tie-in Connection — Tie-in connection to existing 300mm dia sewer pipe",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2680
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/38-F",
          "item_code": "F",
          "section": "FIRE FIGHTING INSTALLATION",
          "heading_path": [
            "Supply and fix fire hydrants including buried gate valve,150mm DI wet barrel pillar type hydrant, pipes and fittings including tee/bend at main pipe, 200 x 150mm stub flanges, thrust blocks, excavation, fine sand bed, concrete foundation, fire hydrant protection barrier, 150 x 150mm surface box, spindles, DI flange adapter, testing and  commissioning, backfilling, disposal of surplus excavated materials and other associated works"
          ],
          "own_description": "Nominal bore; 150mm dia Fire Hydrant",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — FIRE FIGHTING INSTALLATION — Supply and fix fire hydrants including buried gate valve,150mm DI wet barrel pillar type hydrant, pipes and fittings including tee/bend at main pipe, 200 x 150mm stub flanges, thrust blocks, excavation, fine sand bed, concrete foundation, fire hydrant protection barrier, 150 x 150mm surface box, spindles, DI flange adapter, testing and  commissioning, backfilling, disposal of surplus excavated materials and other associated works — Nominal bore; 150mm dia Fire Hydrant",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 30950,
          "amount_aed": 185700,
          "amount_state": "number",
          "printed_page": "3/Q/3",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2686
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "185,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/39",
      "section": "IRRIGATION INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 565907,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/39-A",
          "item_code": "A",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation System",
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Trench excavation for external services; including all ancillary works as necessary",
            "Excavation of trenches for Irrigation pipes (measured separately); including warning tape, backfill, disposal, and compaction"
          ],
          "own_description": "Average depth of trench exceeding 1000mm but not exceeding 1500mm",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation System — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Trench excavation for external services; including all ancillary works as necessary — Excavation of trenches for Irrigation pipes (measured separately); including warning tape, backfill, disposal, and compaction — Average depth of trench exceeding 1000mm but not exceeding 1500mm",
          "quantity": 5531,
          "unit": "m",
          "rate_aed": 27,
          "amount_aed": 149337,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2717
          },
          "extra_columns": {
            "GF & Podium [D]": "5,531",
            "TOTAL QTY [I]": "5,531",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "149,337.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-B",
          "item_code": "B",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary",
            "uPVC irrigation pipe"
          ],
          "own_description": "25mm (1 inch) diameter class\"E\"",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary — uPVC irrigation pipe — 25mm (1 inch) diameter class\"E\"",
          "quantity": 2640,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 52800,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2723
          },
          "extra_columns": {
            "GF & Podium [D]": "2,640",
            "TOTAL QTY [I]": "2,640",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "52,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-C",
          "item_code": "C",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary",
            "uPVC irrigation pipe"
          ],
          "own_description": "40mm (1.5 inch) diameter class\"D\"",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary — uPVC irrigation pipe — 40mm (1.5 inch) diameter class\"D\"",
          "quantity": 1182,
          "unit": "m",
          "rate_aed": 40,
          "amount_aed": 47280,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2725
          },
          "extra_columns": {
            "GF & Podium [D]": "1,182",
            "TOTAL QTY [I]": "1,182",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "47,280.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-D",
          "item_code": "D",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary",
            "uPVC irrigation pipe"
          ],
          "own_description": "50mm (2 inch) diameter class\"D\"",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary — uPVC irrigation pipe — 50mm (2 inch) diameter class\"D\"",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 4250,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2727
          },
          "extra_columns": {
            "GF & Podium [D]": "85",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-E",
          "item_code": "E",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary",
            "uPVC irrigation pipe"
          ],
          "own_description": "75mm (3 inch) diameter class\"D\"",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary — uPVC irrigation pipe — 75mm (3 inch) diameter class\"D\"",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2729
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-F",
          "item_code": "F",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary",
            "uPVC irrigation pipe"
          ],
          "own_description": "100mm (4 inch) diameter class\"D\"",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Bed and surround to irrigation pipes; Sand bed with selected backfill and ancillary work as necessary — uPVC irrigation pipe — 100mm (4 inch) diameter class\"D\"",
          "quantity": 1099,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 109900,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2731
          },
          "extra_columns": {
            "GF & Podium [D]": "1,099",
            "TOTAL QTY [I]": "1,099",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "109,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-G",
          "item_code": "G",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "uPVC Main line"
          ],
          "own_description": "100mm (4 inch) diameter class D",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — uPVC Main line — 100mm (4 inch) diameter class D",
          "quantity": 1099,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 109900,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2737
          },
          "extra_columns": {
            "GF & Podium [D]": "1,099",
            "TOTAL QTY [I]": "1,099",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "109,900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-H",
          "item_code": "H",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "uPVC Main line"
          ],
          "own_description": "50mm (2 inch) diameter class D",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — uPVC Main line — 50mm (2 inch) diameter class D",
          "quantity": 85,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 4250,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2739
          },
          "extra_columns": {
            "GF & Podium [D]": "85",
            "TOTAL QTY [I]": "85",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-J",
          "item_code": "J",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Drip line"
          ],
          "own_description": "25mm (1 inch) diameter class E",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Drip line — 25mm (1 inch) diameter class E",
          "quantity": 2350,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 47000,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2743
          },
          "extra_columns": {
            "GF & Podium [D]": "2,350",
            "TOTAL QTY [I]": "2,350",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "47,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-K",
          "item_code": "K",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Drip line"
          ],
          "own_description": "40mm (1.5 inch) diameter class D",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Drip line — 40mm (1.5 inch) diameter class D",
          "quantity": 1011,
          "unit": "m",
          "rate_aed": 40,
          "amount_aed": 40440,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2745
          },
          "extra_columns": {
            "GF & Podium [D]": "1,011",
            "TOTAL QTY [I]": "1,011",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "40,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/39-L",
          "item_code": "L",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Drip line"
          ],
          "own_description": "75mm (3 inch) diameter class D",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Drip line — 75mm (3 inch) diameter class D",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 75,
          "amount_aed": 375,
          "amount_state": "number",
          "printed_page": "3/Q/4",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2747
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "375.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/40",
      "section": "IRRIGATION INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 293480,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/40-A",
          "item_code": "A",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Sprinkler line"
          ],
          "own_description": "25mm (1 inch) diameter class E",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Sprinkler line — 25mm (1 inch) diameter class E",
          "quantity": 290,
          "unit": "m",
          "rate_aed": 25,
          "amount_aed": 7250,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2766
          },
          "extra_columns": {
            "GF & Podium [D]": "290",
            "TOTAL QTY [I]": "290",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-B",
          "item_code": "B",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Sprinkler line"
          ],
          "own_description": "40mm (1.5 inch) diameter class D",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Sprinkler line — 40mm (1.5 inch) diameter class D",
          "quantity": 171,
          "unit": "m",
          "rate_aed": 100,
          "amount_aed": 17100,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2768
          },
          "extra_columns": {
            "GF & Podium [D]": "171",
            "TOTAL QTY [I]": "171",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "17,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-C",
          "item_code": "C",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "uPVC irrigation duct"
          ],
          "own_description": "2 x 150mm diameter",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — uPVC irrigation duct — 2 x 150mm diameter",
          "quantity": 215,
          "unit": "m",
          "rate_aed": 300,
          "amount_aed": 64500,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2772
          },
          "extra_columns": {
            "GF & Podium [D]": "215",
            "TOTAL QTY [I]": "215",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "64,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-D",
          "item_code": "D",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Expansion joint sleeve"
          ],
          "own_description": "800 to 1000mm below finished surface",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Expansion joint sleeve — 800 to 1000mm below finished surface",
          "quantity": 257,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 46260,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2776
          },
          "extra_columns": {
            "GF & Podium [D]": "257",
            "TOTAL QTY [I]": "257",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "46,260.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-E",
          "item_code": "E",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately)",
            "Concealed sleeve"
          ],
          "own_description": "Vertical concealed sleeve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation system; including piping, valves, fittings, supports and ancillary work as necessary (excavation and disposal measured separately) — Concealed sleeve — Vertical concealed sleeve",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 180,
          "amount_aed": 900,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2780
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "900.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-F",
          "item_code": "F",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Quick coupling valve"
          ],
          "own_description": "25mm (1 inch) Quick coupling valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Quick coupling valve — 25mm (1 inch) Quick coupling valve",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2786
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-G",
          "item_code": "G",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Quick coupling valve"
          ],
          "own_description": "50mm (2\") Quick coupling valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Quick coupling valve — 50mm (2\") Quick coupling valve",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 850,
          "amount_aed": 850,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2788
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "850.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-H",
          "item_code": "H",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Quick coupling valve"
          ],
          "own_description": "100mm (4\") Quick coupling valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Quick coupling valve — 100mm (4\") Quick coupling valve",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 5100,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2790
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,100.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-J",
          "item_code": "J",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "End cap"
          ],
          "own_description": "100mm (4\") End cap",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — End cap — 100mm (4\") End cap",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 125,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2794
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-K",
          "item_code": "K",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Isolation valve"
          ],
          "own_description": "100mm (4\") Isolation valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Isolation valve — 100mm (4\") Isolation valve",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1700,
          "amount_aed": 6800,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2798
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-L",
          "item_code": "L",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV12; 1\" diameter, 0.26 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV12; 1\" diameter, 0.26 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2802
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-M",
          "item_code": "M",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV-12; 1\" diameter, 0.27 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV-12; 1\" diameter, 0.27 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2804
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-N",
          "item_code": "N",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV13; 1\" diameter, 0.24 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV13; 1\" diameter, 0.24 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2806
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-P",
          "item_code": "P",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV13; 1\" diameter, 0.11 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV13; 1\" diameter, 0.11 LPS",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 3080,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2808
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-Q",
          "item_code": "Q",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV12; 1\" diameter, 0.21 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV12; 1\" diameter, 0.21 LPS",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 3080,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2810
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/40-R",
          "item_code": "R",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV5; 1\" diameter, 0.16 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV5; 1\" diameter, 0.16 LPS",
          "quantity": 86,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 132440,
          "amount_state": "number",
          "printed_page": "3/Q/5",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2812
          },
          "extra_columns": {
            "GF & Podium [D]": "86",
            "TOTAL QTY [I]": "86",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "132,440.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/41",
      "section": "IRRIGATION INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 221980,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/41-A",
          "item_code": "A",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV4; 1.5\" diameter, 2.53 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV4; 1.5\" diameter, 2.53 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2828
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-B",
          "item_code": "B",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV5; 1.5\" diameter, 2.2 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV5; 1.5\" diameter, 2.2 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2830
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-C",
          "item_code": "C",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV5; 1.5\" diameter, 1.23 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV5; 1.5\" diameter, 1.23 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2832
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-D",
          "item_code": "D",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV6; 1.5\" diameter, 2 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV6; 1.5\" diameter, 2 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2834
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-E",
          "item_code": "E",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV7; 1.5\" diameter, 1.38 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV7; 1.5\" diameter, 1.38 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2836
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-F",
          "item_code": "F",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV8; 1.5\" diameter, 1.56 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV8; 1.5\" diameter, 1.56 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2838
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-G",
          "item_code": "G",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV1; 1.5\" diameter, 3.28 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV1; 1.5\" diameter, 3.28 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2840
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-H",
          "item_code": "H",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV3; 1.5\" diameter, 2.52 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV3; 1.5\" diameter, 2.52 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2842
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-J",
          "item_code": "J",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV4; 1.5\" diameter, 2.66 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV4; 1.5\" diameter, 2.66 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2844
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-K",
          "item_code": "K",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV6; 1.5\" diameter, 2.04 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV6; 1.5\" diameter, 2.04 LPS",
          "quantity": 51,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 78540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2846
          },
          "extra_columns": {
            "GF & Podium [D]": "51",
            "TOTAL QTY [I]": "51",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "78,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-L",
          "item_code": "L",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV1; 2\" diameter, 4 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV1; 2\" diameter, 4 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2848
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-M",
          "item_code": "M",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV2; 2\" diameter, 2.61 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV2; 2\" diameter, 2.61 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2850
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-N",
          "item_code": "N",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "SV1; 2\" diameter, 4.5 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — SV1; 2\" diameter, 4.5 LPS",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 9240,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2852
          },
          "extra_columns": {
            "GF & Podium [D]": "6",
            "TOTAL QTY [I]": "6",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "9,240.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-P",
          "item_code": "P",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV1; 2 inch diameter, 4.01 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV1; 2 inch diameter, 4.01 LPS",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2854
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-Q",
          "item_code": "Q",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Solenoid valve"
          ],
          "own_description": "DV3; 1.5 inch diameter, 1.69 LPS",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Solenoid valve — DV3; 1.5 inch diameter, 1.69 LPS",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 3080,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2856
          },
          "extra_columns": {
            "GF & Podium [D]": "2",
            "TOTAL QTY [I]": "2",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,080.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-R",
          "item_code": "R",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Drip riser"
          ],
          "own_description": "25mm (1\") diameter Drip riser",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Drip riser — 25mm (1\") diameter Drip riser",
          "quantity": 238,
          "unit": "Nr.",
          "rate_aed": 120,
          "amount_aed": 28560,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2860
          },
          "extra_columns": {
            "GF & Podium [D]": "238",
            "TOTAL QTY [I]": "238",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "28,560.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-S",
          "item_code": "S",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Accessories; including supports, excavation, disposal and ancillary work as necessary",
            "Double Dripline ring"
          ],
          "own_description": "25mm (1\") diameter",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Accessories; including supports, excavation, disposal and ancillary work as necessary — Double Dripline ring — 25mm (1\") diameter",
          "quantity": 441,
          "unit": "Nr.",
          "rate_aed": 130,
          "amount_aed": 57330,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2864
          },
          "extra_columns": {
            "GF & Podium [D]": "441",
            "TOTAL QTY [I]": "441",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "57,330.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-T",
          "item_code": "T",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Pull box; including gravel base recessed cover, excavation, backfilling, disposal, compaction, solid block work,150mm compacted sub-base, 50mm thick PCC, indication tag and ancillary work as necessary"
          ],
          "own_description": "Pull box",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Pull box; including gravel base recessed cover, excavation, backfilling, disposal, compaction, solid block work,150mm compacted sub-base, 50mm thick PCC, indication tag and ancillary work as necessary — Pull box",
          "quantity": 19,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 4750,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2868
          },
          "extra_columns": {
            "GF & Podium [D]": "19",
            "TOTAL QTY [I]": "19",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "4,750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-U",
          "item_code": "U",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Irrigation controller",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary — Irrigation controller",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3600,
          "amount_aed": 3600,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2872
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/41-V",
          "item_code": "V",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "1 inch uPVC Conduit for irrigation controller cable",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary — 1 inch uPVC Conduit for irrigation controller cable",
          "quantity": 920,
          "unit": "m",
          "rate_aed": 20,
          "amount_aed": 18400,
          "amount_state": "number",
          "printed_page": "3/Q/6",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2874
          },
          "extra_columns": {
            "GF & Podium [D]": "920",
            "TOTAL QTY [I]": "920",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "18,400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/42",
      "section": "IRRIGATION INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 312040,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/42-A",
          "item_code": "A",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary"
          ],
          "own_description": "Allow for connection of irrigation pipe with existing infrastructure network including ancillary work as necessary",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation controller; including foundation, 100mm diameter conduit for valve cables, 40mm diameter conduit for ground cable, copper earthing, electrical connection, supports and ancillary work as necessary — Allow for connection of irrigation pipe with existing infrastructure network including ancillary work as necessary",
          "quantity": 1,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 5000,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2887
          },
          "extra_columns": {
            "Basement [C]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-B",
          "item_code": "B",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Automatic screen filter 100-500 Micron",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Automatic screen filter 100-500 Micron",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2893
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-C",
          "item_code": "C",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Basket SS 316 Strainer",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Basket SS 316 Strainer",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2895
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-D",
          "item_code": "D",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Brass check valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Brass check valve",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1250,
          "amount_aed": 1250,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2897
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-E",
          "item_code": "E",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Brass gate valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Brass gate valve",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 800,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2899
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-F",
          "item_code": "F",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Butterfly valve",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Butterfly valve",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 1000,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2901
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-G",
          "item_code": "G",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Electromagnetic flow meter",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Electromagnetic flow meter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5969,
          "amount_aed": 5969,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2903
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,969.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-H",
          "item_code": "H",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Pressure gauge",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Pressure gauge",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1156,
          "amount_aed": 1156,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2905
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,156.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-J",
          "item_code": "J",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Pressure switch",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Pressure switch",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 500,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2907
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-K",
          "item_code": "K",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Pressure transmitter",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Pressure transmitter",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 6324.999999999999,
          "amount_aed": 6324.999999999999,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2909
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,325.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-L",
          "item_code": "L",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Pressure vessel",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Pressure vessel",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 10000,
          "amount_aed": 10000,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2911
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "10,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-M",
          "item_code": "M",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Solenoid valve for automatic filter drain",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Solenoid valve for automatic filter drain",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1540,
          "amount_aed": 1540,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2913
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "1,540.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-N",
          "item_code": "N",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Vertical Multi stage centrifugal pump with VFD (1D + 1S)",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Vertical Multi stage centrifugal pump with VFD (1D + 1S)",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 60000,
          "amount_aed": 60000,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2915
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "60,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-P",
          "item_code": "P",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Irrigation pump control panel",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Irrigation pump control panel",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 50000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2917
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/42-Q",
          "item_code": "Q",
          "section": "IRRIGATION INSTALLATION",
          "heading_path": [
            "Irrigation pumping station",
            "Equipment"
          ],
          "own_description": "Allow for the construction of Irrigation pump room and tank including but not limited to pipeworks, ducts, cables, fittings, valves, chambers, mechanical and electrical works and all necessary works in accordance with the drawings and specifications.",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — IRRIGATION INSTALLATION — Irrigation pumping station — Equipment — Allow for the construction of Irrigation pump room and tank including but not limited to pipeworks, ducts, cables, fittings, valves, chambers, mechanical and electrical works and all necessary works in accordance with the drawings and specifications.",
          "quantity": 111,
          "unit": "m2",
          "rate_aed": 1500,
          "amount_aed": 166500,
          "amount_state": "number",
          "printed_page": "3/Q/7",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2919
          },
          "extra_columns": {
            "GF & Podium [D]": "111",
            "TOTAL QTY [I]": "111",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "166,500.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/43",
      "section": "SUNDRIES",
      "sheet": "3 - Ext",
      "source_collection_aed": 92727.35,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/43-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for all supports, fixings, anchors and insulating blocks where not included above or elsewhere",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2947
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all identification including painting, marking and labelling",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for all identification including painting, marking and labelling",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2949
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 92727.35,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2951
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "92,727.35",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/43-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed installation",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2953
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing spares for the Mechanical Engineering Installation",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for providing spares for the Mechanical Engineering Installation",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2955
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/43-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2957
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-G",
          "item_code": "G",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2961
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-H",
          "item_code": "H",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for liaison with obtaining approvals and attendance on approved Authorities, other statutory bodies and service providers as required",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2963
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-J",
          "item_code": "J",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2965
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-K",
          "item_code": "K",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2967
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-L",
          "item_code": "L",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for training the Employer's Staff to operate and maintain the Mechanical Engineering Installations",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2969
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-M",
          "item_code": "M",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Work Incidental to Mechanical Engineering Installations — Allow for all incidental work to the Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2971
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/43-N",
          "item_code": "N",
          "section": "SUNDRIES",
          "heading_path": [
            "Builders work in connection (BWIC) with Mechanical Engineering Installations"
          ],
          "own_description": "Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — SUNDRIES — Builders work in connection (BWIC) with Mechanical Engineering Installations — Allow for all BWIC with Mechanical Engineering Installations where not included above or elsewhere",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/Q/8",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2975
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/44",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/44-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Mechanical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION Q - MECHANICAL ENGINEERING INSTALLATIONS (3/Q) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Mechanical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/Q/9",
          "bill_ref": "3",
          "section_ref": "3/Q",
          "source": {
            "sheet": "3 - Ext",
            "row": 2992
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/45",
      "section": "SUB - MAIN INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 32918,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/45-A",
          "item_code": "A",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Allow for Sub-main cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Allow for Sub-main cables; including fixings, supports, terminations, accessories and all ancillary works as necessary",
          "quantity": 22893,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3117
          },
          "extra_columns": {
            "GF & Podium [D]": "20,921",
            "Tower 1 [E]": "481",
            "Tower 2 [F]": "522",
            "Tower 3 [G]": "481",
            "Tower 4 [H]": "488",
            "TOTAL QTY [I]": "22,893",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-B",
          "item_code": "B",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Allow for Equipment (DB, kwh meter, containment, ducts, etc); including fixings, supports, hangers, concrete base, plinths, earth works, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Allow for Equipment (DB, kwh meter, containment, ducts, etc); including fixings, supports, hangers, concrete base, plinths, earth works, accessories and all ancillary works as necessary",
          "quantity": 25649,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3119
          },
          "extra_columns": {
            "GF & Podium [D]": "23,465",
            "Tower 1 [E]": "537",
            "Tower 2 [F]": "572",
            "Tower 3 [G]": "537",
            "Tower 4 [H]": "538",
            "TOTAL QTY [I]": "25,649"
          }
        },
        {
          "id": "3 - Ext/45-C",
          "item_code": "C",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Allow for Excavation of trenches; including earthwork support, disposal, compaction, backfilling, marking tape, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Allow for Excavation of trenches; including earthwork support, disposal, compaction, backfilling, marking tape, accessories and all ancillary works as necessary",
          "quantity": 15341,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3121
          },
          "extra_columns": {
            "GF & Podium [D]": "13,763",
            "Tower 1 [E]": "389",
            "Tower 2 [F]": "417",
            "Tower 3 [G]": "389",
            "Tower 4 [H]": "383",
            "TOTAL QTY [I]": "15,341"
          }
        },
        {
          "id": "3 - Ext/45-D",
          "item_code": "D",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Allow for Connection to supply mains; including cables, conduits, fixings, supports, terminations, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Allow for Connection to supply mains; including cables, conduits, fixings, supports, terminations, accessories and all ancillary works as necessary",
          "quantity": 5760,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3123
          },
          "extra_columns": {
            "GF & Podium [D]": "5,652",
            "Tower 1 [E]": "22",
            "Tower 2 [F]": "32",
            "Tower 3 [G]": "22",
            "Tower 4 [H]": "32",
            "TOTAL QTY [I]": "5,760"
          }
        },
        {
          "id": "3 - Ext/45-E",
          "item_code": "E",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Allow for  Earthing system; including earthworks, fixings, bondings, connections, joints, earthing cables, earth rods, earth pits, accessories and all ancillary works\r\nas necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Allow for  Earthing system; including earthworks, fixings, bondings, connections, joints, earthing cables, earth rods, earth pits, accessories and all ancillary works\r\nas necessary",
          "quantity": 11172,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3125
          },
          "extra_columns": {
            "GF & Podium [D]": "10,540",
            "Tower 1 [E]": "154",
            "Tower 2 [F]": "162",
            "Tower 3 [G]": "154",
            "Tower 4 [H]": "162",
            "TOTAL QTY [I]": "11,172",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-F",
          "item_code": "F",
          "section": "ELECTRICAL ENGINEERING INSTALLATION",
          "heading_path": [],
          "own_description": "Small power including cables, conduits to termination points and accessories; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — ELECTRICAL ENGINEERING INSTALLATION — Small power including cables, conduits to termination points and accessories; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary",
          "quantity": 928,
          "unit": "m2",
          "rate_aed": null,
          "amount_aed": 0,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3127
          },
          "extra_columns": {
            "GF & Podium [D]": "668",
            "Tower 1 [E]": "64",
            "Tower 2 [F]": "66",
            "Tower 3 [G]": "64",
            "Tower 4 [H]": "66",
            "TOTAL QTY [I]": "928",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-G",
          "item_code": "G",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction"
          ],
          "own_description": "HV cable trench for 2x160mm diameter uPVC duct sleeve",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Excavation of trenches for pipework and fittings (pipes measured separately); including warning tape, backfill, disposal and compaction — HV cable trench for 2x160mm diameter uPVC duct sleeve",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 26,
          "amount_aed": 2834,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3133
          },
          "extra_columns": {
            "GF & Podium [D]": "109",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,834.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-H",
          "item_code": "H",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Trenches"
          ],
          "own_description": "HV cable trench for 2x160mm diameter uPVC duct sleeve",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Trenches — HV cable trench for 2x160mm diameter uPVC duct sleeve",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 26,
          "amount_aed": 2834,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3137
          },
          "extra_columns": {
            "GF & Podium [D]": "109",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,834.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-J",
          "item_code": "J",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Sand bed and surround to pipes"
          ],
          "own_description": "2x160mm diameter uPVC duct sleeve",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Sand bed and surround to pipes — 2x160mm diameter uPVC duct sleeve",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 5450,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3141
          },
          "extra_columns": {
            "GF & Podium [D]": "109",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/45-K",
          "item_code": "K",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "uPVC duct"
          ],
          "own_description": "2x160mm diameter uPVC duct sleeve",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — uPVC duct — 2x160mm diameter uPVC duct sleeve",
          "quantity": 109,
          "unit": "m",
          "rate_aed": 200,
          "amount_aed": 21800,
          "amount_state": "number",
          "printed_page": "3/R/1",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3145
          },
          "extra_columns": {
            "GF & Podium [D]": "109",
            "TOTAL QTY [I]": "109",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "21,800.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/46",
      "section": "SUB - MAIN INSTALLATION",
      "sheet": "3 - Ext",
      "source_collection_aed": 417150,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/46-A",
          "item_code": "A",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Tie-in Connection"
          ],
          "own_description": "Tie-in connection to existing electrical line",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Tie-in Connection — Tie-in connection to existing electrical line",
          "quantity": 1,
          "unit": "item",
          "rate_aed": 50000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3167
          },
          "extra_columns": {
            "Basement [C]": "1.00",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "50,000.00",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-B",
          "item_code": "B",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Small power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Switched socket outlet",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Small power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Switched socket outlet",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 3150,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3173
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "3,150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-C",
          "item_code": "C",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Small power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "63A TPN Isolator explosion proof",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Small power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — 63A TPN Isolator explosion proof",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 2000,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3175
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-D",
          "item_code": "D",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Small power Installation",
            "Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary"
          ],
          "own_description": "Industrial type switched socket outlet (SP+N+E) weather proof",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Small power Installation — Cables and conduits to termination points; including terminations, fixings, supports, hangers, accessories and all ancillary works as necessary — Industrial type switched socket outlet (SP+N+E) weather proof",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 400,
          "amount_aed": 400,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3177
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "400.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-E",
          "item_code": "E",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary woks as necessary"
          ],
          "own_description": "Switched socket outlet",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary woks as necessary — Switched socket outlet",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 2700,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3181
          },
          "extra_columns": {
            "GF & Podium [D]": "9",
            "TOTAL QTY [I]": "9",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "2,700.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-F",
          "item_code": "F",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary woks as necessary"
          ],
          "own_description": "63A TPN Isolator explosion proof",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary woks as necessary — 63A TPN Isolator explosion proof",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 6000,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3183
          },
          "extra_columns": {
            "GF & Podium [D]": "4",
            "TOTAL QTY [I]": "4",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "6,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-G",
          "item_code": "G",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Accessories; including fixings, supports, hangers and all ancillary woks as necessary"
          ],
          "own_description": "Industrial type switched socket outlet (SP+N+E) weather proof",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Accessories; including fixings, supports, hangers and all ancillary woks as necessary — Industrial type switched socket outlet (SP+N+E) weather proof",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 300,
          "amount_aed": 300,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3185
          },
          "extra_columns": {
            "GF & Podium [D]": "1",
            "TOTAL QTY [I]": "1",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "300.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-H",
          "item_code": "H",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "Containment"
          ],
          "own_description": "200x50mm cable tray for essential power",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — Containment — 200x50mm cable tray for essential power",
          "quantity": 3,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 150,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3189
          },
          "extra_columns": {
            "GF & Podium [D]": "3",
            "TOTAL QTY [I]": "3",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "150.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-J",
          "item_code": "J",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "External Communication Services",
            "Sand bed and surround to pipes"
          ],
          "own_description": "2x100mm dia uPVC duct for ISP secondary network",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — External Communication Services — Sand bed and surround to pipes — 2x100mm dia uPVC duct for ISP secondary network",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 50,
          "amount_aed": 250,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3195
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-K",
          "item_code": "K",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "External Communication Services",
            "uPVC duct"
          ],
          "own_description": "2x100mm dia uPVC duct for ISP secondary network",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — External Communication Services — uPVC duct — 2x100mm dia uPVC duct for ISP secondary network",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 150,
          "amount_aed": 750,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3199
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "750.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-L",
          "item_code": "L",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "External Communication Services",
            "Tie-in Connection"
          ],
          "own_description": "Tie-in connection to existing communication line",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — External Communication Services — Tie-in Connection — Tie-in connection to existing communication line",
          "quantity": 5,
          "unit": "m",
          "rate_aed": 10000,
          "amount_aed": 50000,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3203
          },
          "extra_columns": {
            "GF & Podium [D]": "5",
            "TOTAL QTY [I]": "5",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "50,000.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/46-M",
          "item_code": "M",
          "section": "SUB - MAIN INSTALLATION",
          "heading_path": [
            "External Communication Services",
            "Electrical point",
            "External Communication Services"
          ],
          "own_description": "Allow for ICT installation (Data connection); including cables, conduits, terminations, fixings, supports, hangers, data outlets, accessories and all ancillary works as necessary",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUB - MAIN INSTALLATION — External Communication Services — Electrical point — External Communication Services — Allow for ICT installation (Data connection); including cables, conduits, terminations, fixings, supports, hangers, data outlets, accessories and all ancillary works as necessary",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 301450,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/R/2",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3209
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "301,450.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/47",
      "section": "SUNDRIES",
      "sheet": "3 - Ext",
      "source_collection_aed": 1447615.225,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/47-A",
          "item_code": "A",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Final sub-circuits and ancillary installations complete; including cabling, wiring, containment and terminations as necessary"
          ],
          "own_description": "Light points",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Final sub-circuits and ancillary installations complete; including cabling, wiring, containment and terminations as necessary — Light points",
          "quantity": 1005,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 251250,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3226
          },
          "extra_columns": {
            "GF & Podium [D]": "947",
            "Tower 1 [E]": "19",
            "Tower 2 [F]": "39",
            "TOTAL QTY [I]": "1,005",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "236,750.00",
            "TOWER 1 [O]": "4,750.00",
            "TOWER 2 [P]": "9,750.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-B",
          "item_code": "B",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 1.1m; Spike mounted medium beam spike light; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 1.1m; Spike mounted medium beam spike light; 3000 K",
          "quantity": 46,
          "unit": "Nr.",
          "rate_aed": 362,
          "amount_aed": 16652,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3230
          },
          "extra_columns": {
            "GF & Podium [D]": "46",
            "TOTAL QTY [I]": "46",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "16,652.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-C",
          "item_code": "C",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 1.1n - Tree Spike light, Narrow beam, 3000K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 1.1n - Tree Spike light, Narrow beam, 3000K",
          "quantity": 389,
          "unit": "Nr.",
          "rate_aed": 250,
          "amount_aed": 97250,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3232
          },
          "extra_columns": {
            "GF & Podium [D]": "389",
            "TOTAL QTY [I]": "389",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "97,250.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-D",
          "item_code": "D",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 1.3; Tree ring light - medium beam spotlight; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 1.3; Tree ring light - medium beam spotlight; 3000 K",
          "quantity": 40,
          "unit": "Nr.",
          "rate_aed": 1040,
          "amount_aed": 41600,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3234
          },
          "extra_columns": {
            "GF & Podium [D]": "40",
            "TOTAL QTY [I]": "40",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "41,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-E",
          "item_code": "E",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 2.1; Inground medium beam uplight; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 2.1; Inground medium beam uplight; 3000 K",
          "quantity": 28,
          "unit": "Nr.",
          "rate_aed": 374,
          "amount_aed": 10472,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3236
          },
          "extra_columns": {
            "GF & Podium [D]": "20",
            "Tower 2 [F]": "8",
            "TOTAL QTY [I]": "28",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "7,480.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "2,992.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-F",
          "item_code": "F",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 4.1; Recessed pool light, 4000K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 4.1; Recessed pool light, 4000K",
          "quantity": 47,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 235000,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3238
          },
          "extra_columns": {
            "GF & Podium [D]": "40",
            "Tower 1 [E]": "4",
            "Tower 2 [F]": "3",
            "TOTAL QTY [I]": "47",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "200,000.00",
            "TOWER 1 [O]": "20,000.00",
            "TOWER 2 [P]": "15,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-G",
          "item_code": "G",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 4.2; Recessed pool step light, 4000K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 4.2; Recessed pool step light, 4000K",
          "quantity": 128,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 640000,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3240
          },
          "extra_columns": {
            "GF & Podium [D]": "104",
            "Tower 1 [E]": "9",
            "Tower 2 [F]": "15",
            "TOTAL QTY [I]": "128",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "520,000.00",
            "TOWER 1 [O]": "45,000.00",
            "TOWER 2 [P]": "75,000.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-H",
          "item_code": "H",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 5.1; Wall recessed floor washer; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 5.1; Wall recessed floor washer; 3000 K",
          "quantity": 62,
          "unit": "Nr.",
          "rate_aed": 368,
          "amount_aed": 22816,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3242
          },
          "extra_columns": {
            "GF & Podium [D]": "62",
            "TOTAL QTY [I]": "62",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,816.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-J",
          "item_code": "J",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 6.1; Surface mounted bollard; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 6.1; Surface mounted bollard; 3000 K",
          "quantity": 104,
          "unit": "Nr.",
          "rate_aed": 493,
          "amount_aed": 51272,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3244
          },
          "extra_columns": {
            "GF & Podium [D]": "104",
            "TOTAL QTY [I]": "104",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "51,272.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-K",
          "item_code": "K",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 7.1; Surface mounted downlight; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 7.1; Surface mounted downlight; 3000 K",
          "quantity": 88,
          "unit": "Nr.",
          "rate_aed": 261,
          "amount_aed": 22968,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3246
          },
          "extra_columns": {
            "GF & Podium [D]": "88",
            "TOTAL QTY [I]": "88",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "22,968.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-L",
          "item_code": "L",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "LTL 8.1; Surface mounted floor washer; 3000 K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — LTL 8.1; Surface mounted floor washer; 3000 K",
          "quantity": 57,
          "unit": "Nr.",
          "rate_aed": 339,
          "amount_aed": 19323,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3248
          },
          "extra_columns": {
            "GF & Podium [D]": "38",
            "Tower 1 [E]": "6",
            "Tower 2 [F]": "13",
            "TOTAL QTY [I]": "57",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "12,882.00",
            "TOWER 1 [O]": "2,034.00",
            "TOWER 2 [P]": "4,407.00",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-M",
          "item_code": "M",
          "section": "LIGHTING INSTALLATION",
          "heading_path": [
            "Light fittings; including fixings, supports, hangers and all ancillary works as necessary"
          ],
          "own_description": "TLTL 8.2 -Asymmetric drive over floor washer, 3000K",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — LIGHTING INSTALLATION — Light fittings; including fixings, supports, hangers and all ancillary works as necessary — TLTL 8.2 -Asymmetric drive over floor washer, 3000K",
          "quantity": 16,
          "unit": "Nr.",
          "rate_aed": 350,
          "amount_aed": 5600,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3250
          },
          "extra_columns": {
            "GF & Podium [D]": "16",
            "TOTAL QTY [I]": "16",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "5,600.00",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-N",
          "item_code": "N",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for earthing and bonding as specified; in particular all metal containments shall be",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for earthing and bonding as specified; in particular all metal containments shall be",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3254
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/47-P",
          "item_code": "P",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all supports, fixings, anchors and insulating blocks where not included above or  elsewhere",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for all supports, fixings, anchors and insulating blocks where not included above or  elsewhere",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3256
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/47-Q",
          "item_code": "Q",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for all identification including painting, marking and labeling",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for all identification including painting, marking and labeling",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3258
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/47-R",
          "item_code": "R",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant Specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for inspection, testing and commissioning including all off-site and factory testing; inspections to demonstrate compliance with relevant Specifications and standards; operating the completed installations; submitting all relevant test record sheets at the completion of the installations",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 33412.225,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3260
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "33,412.22",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/47-S",
          "item_code": "S",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed \r\ninstallation",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for providing in suitable quantities all special tools, operating handles and keys or other equipment necessary for installation, maintenance or operation of the completed \r\ninstallation",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/3",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3262
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/48",
      "section": "SUNDRIES",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/48-A",
          "item_code": "A",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing spares for the Electrical Engineering Installation",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for providing spares for the Electrical Engineering Installation",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3272
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "[S]": "TRUE"
          }
        },
        {
          "id": "3 - Ext/48-B",
          "item_code": "B",
          "section": "SUNDRIES",
          "heading_path": [],
          "own_description": "Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Allow for providing comprehensive equipment documentation including operating instructions and maintenance manuals, record documents, warranties, guarantees, drawings and the like",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3274
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-C",
          "item_code": "C",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for planning and coordinating with relevant statutory authorities and with all other trades",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3278
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-D",
          "item_code": "D",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for liaison with obtaining approvals and attendance on DEWA, other statutory bodies and service providers as required",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for liaison with obtaining approvals and attendance on DEWA, other statutory bodies and service providers as required",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3280
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-E",
          "item_code": "E",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for marking the positions of and cutting or forming holes, mortices, chases or the like and all making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3282
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-F",
          "item_code": "F",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for supplying and fixing all sleeves, frames and built-in fire stoppers for building into concrete structures and masonry walls",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3284
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-G",
          "item_code": "G",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for supplying and fixing all brackets, clamps and other fixing devices including building in or cutting and pinning and all making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3286
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-H",
          "item_code": "H",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for fire stopping all cables, conduit, trucking, cable tray and the like at penetrations through fire walls and other structures and  making good",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for fire stopping all cables, conduit, trucking, cable tray and the like at penetrations through fire walls and other structures and  making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3288
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-J",
          "item_code": "J",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for all incidental work including factory finishing, fixing to all backgrounds by appropriate means and all making good",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3290
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-K",
          "item_code": "K",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for training the Employer's Staff to operate  and maintain the Electrical Engineering Installation",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for training the Employer's Staff to operate  and maintain the Electrical Engineering Installation",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3292
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        },
        {
          "id": "3 - Ext/48-L",
          "item_code": "L",
          "section": "SUNDRIES",
          "heading_path": [
            "Work Incidental to Electrical Engineering Installations"
          ],
          "own_description": "Allow for all incidental work to the Electrical Engineering Installation where not included above or elsewhere",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — SUNDRIES — Work Incidental to Electrical Engineering Installations — Allow for all incidental work to the Electrical Engineering Installation where not included above or elsewhere",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_printed": "included",
          "amount_state": "text",
          "printed_page": "3/R/4",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3294
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "included",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-"
          }
        }
      ]
    },
    {
      "page_ref": "3 - Ext/49",
      "section": "GENERALLY",
      "sheet": "3 - Ext",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3 - Ext/49-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the Electrical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "full_description": "Bill 3 — SECTION R - ELECTRICAL INSTALLATIONS (3/R) — GENERALLY — Allow for any other works which are not included above and which are required to complete the Electrical Engineering Installations in accordance with the Specification and the Drawings (Tenderer to list below):",
          "quantity": 0,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "number",
          "printed_page": "3/R/5",
          "bill_ref": "3",
          "section_ref": "3/R",
          "source": {
            "sheet": "3 - Ext",
            "row": 3319
          },
          "extra_columns": {
            "TOTAL QTY [I]": "0",
            "BASEMENTS [M]": "-",
            "GF & PODIUM [N]": "-",
            "TOWER 1 [O]": "-",
            "TOWER 2 [P]": "-",
            "TOWER 3 [Q]": "-",
            "TOWER 4 [R]": "-",
            "[S]": "TRUE"
          }
        }
      ]
    },
    {
      "page_ref": "Bill 4/1",
      "section": "PROVISIONAL SUMS",
      "sheet": "Bill 4",
      "source_collection_aed": 5720000,
      "section_notes": [],
      "items": [
        {
          "id": "Bill 4/1-A",
          "item_code": "A",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "Workforce Productivity System"
          ],
          "own_description": "Workforce productivity monitoring system (AED1,000,000)",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — Workforce Productivity System — Workforce productivity monitoring system (AED1,000,000)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 1000000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 12
          }
        },
        {
          "id": "Bill 4/1-B",
          "item_code": "B",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "Workforce Productivity System"
          ],
          "own_description": "Main Contractor's OH&P of 4%",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — Workforce Productivity System — Main Contractor's OH&P of 4%",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 40000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 14
          }
        },
        {
          "id": "Bill 4/1-C",
          "item_code": "C",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "RTA ROW Access"
          ],
          "own_description": "Design and build of the RTA ROW accesses in the adjacent DM-owned plot as per SOPR, Clause 1.6 b",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — RTA ROW Access — Design and build of the RTA ROW accesses in the adjacent DM-owned plot as per SOPR, Clause 1.6 b",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 3500000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 18
          }
        },
        {
          "id": "Bill 4/1-D",
          "item_code": "D",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "RTA ROW Access"
          ],
          "own_description": "Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — RTA ROW Access — Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 140000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 20
          }
        },
        {
          "id": "Bill 4/1-E",
          "item_code": "E",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "Active Harmonic Filters"
          ],
          "own_description": "Supply and installation of Active Harmonic Filters",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — Active Harmonic Filters — Supply and installation of Active Harmonic Filters",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 1000000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 24
          }
        },
        {
          "id": "Bill 4/1-F",
          "item_code": "F",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Items of Works to be Tendered",
            "The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract",
            "Active Harmonic Filters"
          ],
          "own_description": "Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "full_description": "PROVISIONAL SUMS — Items of Works to be Tendered — The Employer shall ascertain and determine by measurement the value of work done and/or Plant provided to which the following Provisional Sums relate in accordance with the Conditions of Contract — Active Harmonic Filters — Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 40000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "Bill 4",
            "row": 26
          }
        },
        {
          "id": "Bill 4/1-G",
          "item_code": "G",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Kitchen Cabinets (incl. Counters and Backsplash)"
          ],
          "own_description": "Supply and installation of Kitchen Cabinets (incl. Counters and Backsplash)",
          "full_description": "PROVISIONAL SUMS — Kitchen Cabinets (incl. Counters and Backsplash) — Supply and installation of Kitchen Cabinets (incl. Counters and Backsplash)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "Bill 4",
            "row": 30
          }
        },
        {
          "id": "Bill 4/1-H",
          "item_code": "H",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Kitchen Cabinets (incl. Counters and Backsplash)"
          ],
          "own_description": "Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "full_description": "PROVISIONAL SUMS — Kitchen Cabinets (incl. Counters and Backsplash) — Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "Bill 4",
            "row": 32
          }
        },
        {
          "id": "Bill 4/1-J",
          "item_code": "J",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Elevators"
          ],
          "own_description": "Supply and installation of Elevators",
          "full_description": "PROVISIONAL SUMS — Elevators — Supply and installation of Elevators",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "Bill 4",
            "row": 36
          }
        },
        {
          "id": "Bill 4/1-K",
          "item_code": "K",
          "section": "PROVISIONAL SUMS",
          "heading_path": [
            "Elevators"
          ],
          "own_description": "Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "full_description": "PROVISIONAL SUMS — Elevators — Main Contractor's OH&P, associated builders work and attendance including all incidentals costs, 4%",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "Bill 4",
            "row": 38
          }
        }
      ]
    },
    {
      "page_ref": "3M/1",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 174260,
      "section_notes": [],
      "items": [
        {
          "id": "3M/1-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-101; coffee table; Honed navona travertine top finish with white oak finish legs; including 910mm diameter x 350mm high low table and 1066mm diameter x 400mm high table",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-101; coffee table; Honed navona travertine top finish with white oak finish legs; including 910mm diameter x 350mm high low table and 1066mm diameter x 400mm high table",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4940,
          "amount_aed": 19760,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 12
          },
          "extra_columns": {
            "User1 [G]": "Stillmade-Nesting Tripod coffe table",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-102; Side table; African sapele wood, natural pigmentations and oiled finish; size: 400mm diameter x 480mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-102; Side table; African sapele wood, natural pigmentations and oiled finish; size: 400mm diameter x 480mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 14
          },
          "extra_columns": {
            "User1 [G]": "Studio Anansi-Adah side table or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-103; Side table; Bright gold finish; size: 280mm diameter x 560mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-103; Side table; Bright gold finish; size: 280mm diameter x 560mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 700,
          "amount_aed": 2800,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 16
          },
          "extra_columns": {
            "User1 [G]": "Minotti-still or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-104; Console behind sofa; size: 1495 x 300 x 700mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-104; Console behind sofa; size: 1495 x 300 x 700mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 750,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 18
          },
          "extra_columns": {
            "User1 [G]": "Kifu Paris-Rhapsody console or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-105; Console; white gesso finish; size: 1820 x 350 x 850mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-105; Console; white gesso finish; size: 1820 x 350 x 850mm",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 4550,
          "amount_aed": 27300,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 20
          },
          "extra_columns": {
            "User1 [G]": "Kelly Wearstler-Echo or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-F",
          "item_code": "F",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-106; Side table; size: 500mm diameter x 440mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-106; Side table; size: 500mm diameter x 440mm high",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1250,
          "amount_aed": 7500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 22
          },
          "extra_columns": {
            "User1 [G]": "Designitch-Arflex-Arcolor or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-G",
          "item_code": "G",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-107; Dinning table; Golden oak finish;size: 2900 x 1000 x 750mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-107; Dinning table; Golden oak finish;size: 2900 x 1000 x 750mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7250,
          "amount_aed": 29000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 24
          },
          "extra_columns": {
            "User1 [G]": "Kolkhoze-Automa dining table or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-H",
          "item_code": "H",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-108; Console; size: 1670 x 360 x 800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-108; Console; size: 1670 x 360 x 800mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 4175,
          "amount_aed": 33400,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 26
          },
          "extra_columns": {
            "User1 [G]": "Kelly Wearstler-Roxbury or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-J",
          "item_code": "J",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-109; Coffee table; size: 1645 x 1180 x 400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-109; Coffee table; size: 1645 x 1180 x 400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 28
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-K",
          "item_code": "K",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-09; Shower bench",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-09; Shower bench",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 30
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-L",
          "item_code": "L",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "Reception desk; 800 x 2400mm (measured from drawing)",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — Reception desk; 800 x 2400mm (measured from drawing)",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 30000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 32
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/1-M",
          "item_code": "M",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-110; Side table; Vintage Bronze; 500mm diameter; 600mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-110; Side table; Vintage Bronze; 500mm diameter; 600mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 34
          },
          "extra_columns": {
            "User1 [G]": "The sofa and chair company-river or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        }
      ]
    },
    {
      "page_ref": "3M/2",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 63500,
      "section_notes": [],
      "items": [
        {
          "id": "3M/2-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-111; Side table-Handcrafted organic travertine; 500mm diameter; 500mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-111; Side table-Handcrafted organic travertine; 500mm diameter; 500mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 4000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 44
          },
          "extra_columns": {
            "User1 [G]": "The gallery dubai-lexi or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-112; side table-handcrafted organic travertine; 1720 x 480 x 810mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-112; side table-handcrafted organic travertine; 1720 x 480 x 810mm",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 7500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 46
          },
          "extra_columns": {
            "User1 [G]": "Mous-Axis console or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-113; Communal table travertin; size: 4400 x 1100 x 760mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-113; Communal table travertin; size: 4400 x 1100 x 760mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 48
          },
          "extra_columns": {
            "User1 [G]": "Hommes studio-Billie oval dining table or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-114; Coffee table; 1000mm diameter; 340mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-114; Coffee table; 1000mm diameter; 340mm high",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 50
          },
          "extra_columns": {
            "User1 [G]": "The Gallery Dubai-Lexi or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-115; Coffee table",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-115; Coffee table",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 1500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 52
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-F",
          "item_code": "F",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-116; Armchair side table; size: 500 x 600 x 650mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-116; Armchair side table; size: 500 x 600 x 650mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 1000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 54
          },
          "extra_columns": {
            "User1 [G]": "Maicass-Cabbage table G030 or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-G",
          "item_code": "G",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-117; Sofa side table; Antique Brass finish",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-117; Sofa side table; Antique Brass finish",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 2000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 56
          },
          "extra_columns": {
            "User1 [G]": "Arteriors-Dax Accent or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-H",
          "item_code": "H",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-118; Coffee table; 500mm diameter; 480mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-118; Coffee table; 500mm diameter; 480mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 4000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 58
          },
          "extra_columns": {
            "User1 [G]": "Monologue-E42 or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-J",
          "item_code": "J",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-119; coffee table; 700mm diameter; 330mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-119; coffee table; 700mm diameter; 330mm high",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 60
          },
          "extra_columns": {
            "User1 [G]": "Mogg-Olo or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-K",
          "item_code": "K",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-120; Dining table; size: 4000 x 1000 x 750mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-120; Dining table; size: 4000 x 1000 x 750mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 62
          },
          "extra_columns": {
            "User1 [G]": "Miniform-Barry or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-L",
          "item_code": "L",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-121; Console; size: 1500 x 420 x 800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-121; Console; size: 1500 x 420 x 800mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 64
          },
          "extra_columns": {
            "User1 [G]": "Bloom-Elson or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-M",
          "item_code": "M",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-123; Kids table; size: 750 x 550 x 480mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-123; Kids table; size: 750 x 550 x 480mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 4000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 66
          },
          "extra_columns": {
            "User1 [G]": "Eo-Elephant table or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-N",
          "item_code": "N",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-124; Pool table; 2560mm long x 1410mm wide",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-124; Pool table; 2560mm long x 1410mm wide",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 5000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 68
          },
          "extra_columns": {
            "User1 [G]": "Knight shot-Billiards Breton-Aero pool table or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-P",
          "item_code": "P",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Casegoods"
          ],
          "own_description": "CG-125; Foosball table; size: 1510 x 860 x 920mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Casegoods — CG-125; Foosball table; size: 1510 x 860 x 920mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 70
          },
          "extra_columns": {
            "User1 [G]": "Knight shot-RS barcelona-RS#3 or approved quivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/2-Q",
          "item_code": "Q",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-102; Plant pots",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-102; Plant pots",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 10000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 74
          },
          "extra_columns": {
            "User1 [G]": "Bloomr-White Terrazzo pots or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        }
      ]
    },
    {
      "page_ref": "3M/3",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 1731500,
      "section_notes": [],
      "items": [
        {
          "id": "3M/3-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-104; Artwork behind sofa; size: 1200mm x 1500mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-104; Artwork behind sofa; size: 1200mm x 1500mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 85
          },
          "extra_columns": {
            "User1 [G]": "Galeria9-Orange and Beige or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-105; Artwork above console - handpainted art painting; size: 1800mm x 1500mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-105; Artwork above console - handpainted art painting; size: 1800mm x 1500mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 120000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 87
          },
          "extra_columns": {
            "User1 [G]": "Fizdi - Adstract painting ART-6706-103263 or Approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-106; Artwork at table area; size: 1900mm x 2800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-106; Artwork at table area; size: 1900mm x 2800mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 120000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 89
          },
          "extra_columns": {
            "User1 [G]": "Tassia Bianchini-Crossroads or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-107; Artwork at ground floor parking and lift lobby",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-107; Artwork at ground floor parking and lift lobby",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 91
          },
          "extra_columns": {
            "User1 [G]": "Artpropelled or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-108; Entrance lobby corridor artwork; size: 700 x 1500mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-108; Entrance lobby corridor artwork; size: 700 x 1500mm",
          "quantity": 10,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 300000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 93
          },
          "extra_columns": {
            "User1 [G]": "Curtain: Blindtex-Hazel Almond Manual Track: Blidntex-Forest Group-corded click system or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-F",
          "item_code": "F",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-109; Roller blind",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-109; Roller blind",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 95
          },
          "extra_columns": {
            "User1 [G]": "Roller Blind-Hazel Almond Manual track: Blidntex-forest group - Corded click system or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-G",
          "item_code": "G",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-110; Accessories",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-110; Accessories",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 97
          },
          "extra_columns": {
            "User1 [G]": "West Elm-Foundations Whitewash vases",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-H",
          "item_code": "H",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-111; Artwork; 900mm long x 1100mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-111; Artwork; 900mm long x 1100mm high",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 210000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 99
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-J",
          "item_code": "J",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-113; Curtains manual",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-113; Curtains manual",
          "quantity": 7,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 1750,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 101
          },
          "extra_columns": {
            "User1 [G]": "Curtain: Blindtex-Hazel Almond Manual track: Blidntex-Forest group-corded click system or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-K",
          "item_code": "K",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-114; Plant pots; medium: 550mm diameter, 570mm high; large: 630mm diameter, 680mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-114; Plant pots; medium: 550mm diameter, 570mm high; large: 630mm diameter, 680mm high",
          "quantity": 9,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 18000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 103
          },
          "extra_columns": {
            "User1 [G]": "Bloomr-white Terrazzo pots or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-L",
          "item_code": "L",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-115; Sheer curtains-seating area only",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-115; Sheer curtains-seating area only",
          "quantity": 23,
          "unit": "m",
          "rate_aed": 250,
          "amount_aed": 5750,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 105
          },
          "extra_columns": {
            "User1 [G]": "Curtain: Blindtex-Hazel Almond Motorized track: Giydea ultra 60 or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-M",
          "item_code": "M",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-117; Artwork; size: 1000 x 1400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-117; Artwork; size: 1000 x 1400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 120000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 107
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-N",
          "item_code": "N",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-118; Artwork; size: 1000 x 1400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-118; Artwork; size: 1000 x 1400mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 109
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-P",
          "item_code": "P",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-119; Artwork; size: 2400 x 2400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-119; Artwork; size: 2400 x 2400mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 30000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 111
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-Q",
          "item_code": "Q",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-120; Artwork; size: 1800 x 2300mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-120; Artwork; size: 1800 x 2300mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 113
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-R",
          "item_code": "R",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-121; Artwork; size: 1500 x 2200mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-121; Artwork; size: 1500 x 2200mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 115
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-S",
          "item_code": "S",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-122; Artwork; size: 1600 x 2000mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-122; Artwork; size: 1600 x 2000mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 30000,
          "amount_aed": 60000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 117
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/3-T",
          "item_code": "T",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Miscellaneous"
          ],
          "own_description": "MI-123; Artwork; size: 700 x 1400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Miscellaneous — MI-123; Artwork; size: 700 x 1400mm",
          "quantity": 58,
          "unit": "Nr.",
          "rate_aed": 7500,
          "amount_aed": 435000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 119
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        }
      ]
    },
    {
      "page_ref": "3M/4",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 148500,
      "section_notes": [],
      "items": [
        {
          "id": "3M/4-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-101; Sofa; size: 3460 x 1260 x 700mm; seat height: 400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-101; Sofa; size: 3460 x 1260 x 700mm; seat height: 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3150,
          "amount_aed": 12600,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 131
          },
          "extra_columns": {
            "User1 [G]": "Ghidini-Infinito or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-102; Armchair; Black oiled walnut base finish; size: 830 x 850 x 885mm; seat height: 445mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-102; Armchair; Black oiled walnut base finish; size: 830 x 850 x 885mm; seat height: 445mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 2075,
          "amount_aed": 16600,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 133
          },
          "extra_columns": {
            "User1 [G]": "De-La Espada-Elysia Lounge chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-103; Bench; size: 2130 x 850 x 550mm; seat height: 410mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-103; Bench; size: 2130 x 850 x 550mm; seat height: 410mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5325,
          "amount_aed": 21300,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 135
          },
          "extra_columns": {
            "User1 [G]": "Ralph Pucci-Daybed or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-104; Armchair; size: 900 x 770 x 650mm; seat height: 450mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-104; Armchair; size: 900 x 770 x 650mm; seat height: 450mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 2250,
          "amount_aed": 27000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 137
          },
          "extra_columns": {
            "User1 [G]": "Invisible collection-studio Parisien-Sevigne armchair X Metaphores or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-105; Dining chair; Base: Dark smoked oak finish; size: 475 x 590 x 795mm; seat height: 470mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-105; Dining chair; Base: Dark smoked oak finish; size: 475 x 590 x 795mm; seat height: 470mm",
          "quantity": 32,
          "unit": "Nr.",
          "rate_aed": 1175,
          "amount_aed": 37600,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 139
          },
          "extra_columns": {
            "User1 [G]": "Nor11-Hippo chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-F",
          "item_code": "F",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-106; Sofa; Linen-Olicana-Cabot Husky; size: 2780 x 950 x 650mm; seat height: 370mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-106; Sofa; Linen-Olicana-Cabot Husky; size: 2780 x 950 x 650mm; seat height: 370mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 141
          },
          "extra_columns": {
            "User1 [G]": "NCP-Group Three seat sofa or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-G",
          "item_code": "G",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-107; Lounge chair; size: 686 x 1041 x 565mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-107; Lounge chair; size: 686 x 1041 x 565mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 143
          },
          "extra_columns": {
            "User1 [G]": "Side Gallery-Alta Armchair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-H",
          "item_code": "H",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-108; Pouf-leather; 850mm diameter; 350mm high",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-108; Pouf-leather; 850mm diameter; 350mm high",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 2400,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 145
          },
          "extra_columns": {
            "User1 [G]": "Freifrau-Anna stools or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-J",
          "item_code": "J",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-109; Armchair-Leather; size: 830 x 850 x 790mm; seat height: 420mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-109; Armchair-Leather; size: 830 x 850 x 790mm; seat height: 420mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 600,
          "amount_aed": 4800,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 147
          },
          "extra_columns": {
            "User1 [G]": "Tecni Nova - 1290 chair or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-K",
          "item_code": "K",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-110; Dining chair / option 1 or option 2",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-110; Dining chair / option 1 or option 2",
          "quantity": 30,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 15000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 149
          },
          "extra_columns": {
            "User1 [G]": "Arne Wahl iversen-Rosewood chair or approved equivalent/ Fendi casa-totu chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-L",
          "item_code": "L",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-111; Bench; option 1 or option 2",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-111; Bench; option 1 or option 2",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 151
          },
          "extra_columns": {
            "User1 [G]": "Martin Masse-lppico 01 or approved equivalent/ Ferm living-oval pouf or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-M",
          "item_code": "M",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-112; Ottoman; Fabric: Japandi cream boucle; Base: Walnut",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-112; Ottoman; Fabric: Japandi cream boucle; Base: Walnut",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 1600,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 153
          },
          "extra_columns": {
            "User1 [G]": "Baxton studio-Fisk or Approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/4-N",
          "item_code": "N",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-113; Armchair and pouf; chair size: 900 x 800 x 800mm; pouf size: 600 x 505 x 400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-113; Armchair and pouf; chair size: 900 x 800 x 800mm; pouf size: 600 x 505 x 400mm",
          "quantity": 7,
          "unit": "Nr.",
          "rate_aed": 800,
          "amount_aed": 5600,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 155
          },
          "extra_columns": {
            "User1 [G]": "Bino-home-volume armchair and round pouf or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        }
      ]
    },
    {
      "page_ref": "3M/5",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 125200,
      "section_notes": [],
      "items": [
        {
          "id": "3M/5-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-114; Sofa; light oak fabric frame: Brunswich Melange wool boucle in putty; size: 2100 x 770 x 745mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-114; Sofa; light oak fabric frame: Brunswich Melange wool boucle in putty; size: 2100 x 770 x 745mm",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 9000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 168
          },
          "extra_columns": {
            "User1 [G]": "Studio twenty seven-Bagatelle sofa or qpproved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-115; Armchair; frame: Lacquered metal seat and black: leather",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-115; Armchair; frame: Lacquered metal seat and black: leather",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 170
          },
          "extra_columns": {
            "User1 [G]": "Mambo Unlimited-Blop sofa or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-116; Ottoman; Checker Mushroom fabric; 485 x 6350 x 560mm; seat height: 460mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-116; Ottoman; Checker Mushroom fabric; 485 x 6350 x 560mm; seat height: 460mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 10000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 172
          },
          "extra_columns": {
            "User1 [G]": "Kelly Wearstler-Esfera Ottoman or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-117; Armchair; size: 870 x 760 x 765mm; seat height: 410mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-117; Armchair; size: 870 x 760 x 765mm; seat height: 410mm",
          "quantity": 8,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 8000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 174
          },
          "extra_columns": {
            "User1 [G]": "Ferm Living-Rico chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-118; Sofa in joinery; size: 2470 x 860 x 710mm; seat height: 400mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-118; Sofa in joinery; size: 2470 x 860 x 710mm; seat height: 400mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3500,
          "amount_aed": 14000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 176
          },
          "extra_columns": {
            "User1 [G]": "Audo coppenhagen-Eave modular sofa or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-F",
          "item_code": "F",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-119; Sofa in small seating; size: 2550 x 1410 x 800mm; seat height: 450mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-119; Sofa in small seating; size: 2550 x 1410 x 800mm; seat height: 450mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 3000,
          "amount_aed": 12000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 178
          },
          "extra_columns": {
            "User1 [G]": "Invisible collection-Fuji sofa or apparoved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-G",
          "item_code": "G",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-120; Kids chair 1; size: 360 x 440 x 522mm; seat height: 320mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-120; Kids chair 1; size: 360 x 440 x 522mm; seat height: 320mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 180
          },
          "extra_columns": {
            "User1 [G]": "Eo-Elephant chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-H",
          "item_code": "H",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-121; Kids chair 2; size: 750 x 550 x 480mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-121; Kids chair 2; size: 750 x 550 x 480mm",
          "quantity": 12,
          "unit": "Nr.",
          "rate_aed": 500,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 182
          },
          "extra_columns": {
            "User1 [G]": "Eo-Elephant chair or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-J",
          "item_code": "J",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Upholstered goods"
          ],
          "own_description": "SG-122; Reception chair",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Upholstered goods — SG-122; Reception chair",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 750,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 184
          },
          "extra_columns": {
            "User1 [G]": "Workspace-Marics black task chair or approved equivalant",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-K",
          "item_code": "K",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-101; Seating area loose rug; size: 4800 x 4800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-101; Seating area loose rug; size: 4800 x 4800mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 4800,
          "amount_aed": 19200,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 188
          },
          "extra_columns": {
            "User1 [G]": "Tapis studio-Retro or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-L",
          "item_code": "L",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-102; Big table loose rug; size: 5000 x 2200mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-102; Big table loose rug; size: 5000 x 2200mm",
          "quantity": 4,
          "unit": "Nr.",
          "rate_aed": 5250,
          "amount_aed": 21000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 190
          },
          "extra_columns": {
            "User1 [G]": "Tapis studio-Shaped #030 or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-M",
          "item_code": "M",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-103; Rectangular loose rug; size: 5200 x 3800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-103; Rectangular loose rug; size: 5200 x 3800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 2500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 192
          },
          "extra_columns": {
            "User1 [G]": "Espirit-Velvet spots or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-N",
          "item_code": "N",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-104; Rectangular loose rug; size: 5200 x 3800mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-104; Rectangular loose rug; size: 5200 x 3800mm",
          "quantity": 1,
          "unit": "Nr.",
          "rate_aed": 2500,
          "amount_aed": 2500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 194
          },
          "extra_columns": {
            "User1 [G]": "Fertini casa-luxury rug iconic or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-P",
          "item_code": "P",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-105; Loose rug; size: 3600 x 3100mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-105; Loose rug; size: 3600 x 3100mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 2000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 196
          },
          "extra_columns": {
            "User1 [G]": "Steelcase-Zen series or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/5-Q",
          "item_code": "Q",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-106; Loose rug; 3000mm diameter",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-106; Loose rug; 3000mm diameter",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 2000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 198
          },
          "extra_columns": {
            "User1 [G]": "Pottery Barn Kids-Lorena Canal or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        }
      ]
    },
    {
      "page_ref": "3M/6",
      "section": "LOOSE FURNITURE",
      "sheet": "3M",
      "source_collection_aed": 70500,
      "section_notes": [],
      "items": [
        {
          "id": "3M/6-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Loose rugs"
          ],
          "own_description": "LR-107; Loose rug; size: 3200 x 1700mm",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Loose rugs — LR-107; Loose rug; size: 3200 x 1700mm",
          "quantity": 2,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 2000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 207
          },
          "extra_columns": {
            "User1 [G]": "Rug Artisan-Cerulean or approved equivalent",
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/6-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary",
            "Curtains",
            "Curtain track; comprising curtain fabric, galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories"
          ],
          "own_description": "To apartments",
          "full_description": "LOOSE FURNITURE — Supply of the FFE items, storing, protection, distribution & placement, accessories and all ancillary works as necessary — Curtains — Curtain track; comprising curtain fabric, galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories — To apartments",
          "quantity": 548,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 68500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 213
          },
          "extra_columns": {
            "User2 [H]": "Fixed FF&E",
            "User3 [I]": "6.1"
          }
        }
      ]
    },
    {
      "page_ref": "3M/7",
      "section": "WASTE MANAGEMENT",
      "sheet": "3M",
      "source_collection_aed": 302500,
      "section_notes": [],
      "items": [
        {
          "id": "3M/7-A",
          "item_code": "A",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "1100L wheelie waste bin",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — 1100L wheelie waste bin",
          "quantity": 5,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 7500,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 257
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-B",
          "item_code": "B",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "Dry waste bin",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — Dry waste bin",
          "quantity": 34,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 34000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 259
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-C",
          "item_code": "C",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "Wet waste bin",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — Wet waste bin",
          "quantity": 14,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 14000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 261
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-D",
          "item_code": "D",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "Green waste bin",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — Green waste bin",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 263
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-E",
          "item_code": "E",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "Hazardous waste bin",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — Hazardous waste bin",
          "quantity": 6,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 6000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 265
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-F",
          "item_code": "F",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Waste bins; including all necessary supports, fittings, fixings, grouting and accessories"
          ],
          "own_description": "Wheelie bin compactor",
          "full_description": "WASTE MANAGEMENT — Waste bins; including all necessary supports, fittings, fixings, grouting and accessories — Wheelie bin compactor",
          "quantity": 3,
          "unit": "Nr.",
          "rate_aed": 1000,
          "amount_aed": 3000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 267
          },
          "extra_columns": {
            "User2 [H]": "Loose FF&E",
            "User3 [I]": "6.2"
          }
        },
        {
          "id": "3M/7-G",
          "item_code": "G",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Garbage chute 600mm diameter",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Garbage chute 600mm diameter",
          "quantity": 22,
          "unit": "m",
          "rate_aed": 2500,
          "amount_aed": 55000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 271
          },
          "extra_columns": {
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/7-H",
          "item_code": "H",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Garbage chute 600mm diameter",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Garbage chute 600mm diameter",
          "quantity": 52,
          "unit": "m",
          "rate_aed": 2500,
          "amount_aed": 130000,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 273
          },
          "extra_columns": {
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/7-J",
          "item_code": "J",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "500 X 500 mm chute inlet door",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — 500 X 500 mm chute inlet door",
          "quantity": 24,
          "unit": "Nr.",
          "rate_aed": 2000,
          "amount_aed": 0,
          "amount_printed": "Included",
          "amount_state": "text",
          "source": {
            "sheet": "3M",
            "row": 275
          },
          "extra_columns": {
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/7-K",
          "item_code": "K",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the kids club and multi purpose area  including all necessary fittings, fixings and accessories (approximate area 188 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the kids club and multi purpose area  including all necessary fittings, fixings and accessories (approximate area 188 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 277
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/7-L",
          "item_code": "L",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the kids club and multi purpose area  including all necessary fittings, fixings and accessories (approximate area 132 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the kids club and multi purpose area  including all necessary fittings, fixings and accessories (approximate area 132 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 279
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        }
      ]
    },
    {
      "page_ref": "3M/8",
      "section": "WASTE MANAGEMENT",
      "sheet": "3M",
      "source_collection_aed": 100000,
      "section_notes": [],
      "items": [
        {
          "id": "3M/8-A",
          "item_code": "A",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the gym area; including all necessary fittings, fixings and accessories (approximate area 123 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the gym area; including all necessary fittings, fixings and accessories (approximate area 123 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 292
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/8-B",
          "item_code": "B",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the gym area; including all necessary fittings, fixings and accessories (approximate area 127 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the gym area; including all necessary fittings, fixings and accessories (approximate area 127 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 294
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/8-C",
          "item_code": "C",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the changing room area; including all necessary fittings, fixings and accessories (approximate area 68 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the changing room area; including all necessary fittings, fixings and accessories (approximate area 68 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 296
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        },
        {
          "id": "3M/8-D",
          "item_code": "D",
          "section": "WASTE MANAGEMENT",
          "heading_path": [
            "Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary"
          ],
          "own_description": "Allow a pricing item for equipment items (other than measured items) in the changing room area; including all necessary fittings, fixings and accessories (approximate area 64 sq .m)",
          "full_description": "WASTE MANAGEMENT — Garbage chute; including fittings, supports, cleaning nozzle, vent pipes, exhaust fan, insect/ fly killer, smell reduction unit, sprinklers, fire barriers, fire damper, vent fan, sanitary fixture, finishes, MEP works and all ancillary work as necessary — Allow a pricing item for equipment items (other than measured items) in the changing room area; including all necessary fittings, fixings and accessories (approximate area 64 sq .m)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": 25000,
          "amount_aed": 25000,
          "is_lump_sum": true,
          "amount_state": "number",
          "source": {
            "sheet": "3M",
            "row": 298
          },
          "extra_columns": {
            "User1 [G]": "Refere to the query number B.37",
            "User2 [H]": "Disposal Installations",
            "User3 [I]": "9.1"
          }
        }
      ]
    },
    {
      "page_ref": "3M/9",
      "section": "GENERALLY",
      "sheet": "3M",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "3M/9-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "full_description": "GENERALLY — Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "3M",
            "row": 331
          }
        }
      ]
    },
    {
      "page_ref": "4.1-M/1",
      "section": "LOOSE FURNITURE",
      "sheet": "4.1-M",
      "source_collection_aed": 1739125,
      "section_notes": [],
      "items": [
        {
          "id": "4.1-M/1-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-111; 900 x 1100mm sized; in typical corridors infront of lift lobby above console",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-111; 900 x 1100mm sized; in typical corridors infront of lift lobby above console",
          "quantity": 53,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 265000,
          "amount_state": "number",
          "source": {
            "sheet": "4.1-M",
            "row": 10
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.1-M/1-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-112; 900x1100mm sized; in typical corridors",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-112; 900x1100mm sized; in typical corridors",
          "quantity": 180,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 900000,
          "amount_state": "number",
          "source": {
            "sheet": "4.1-M",
            "row": 12
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.1-M/1-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Console"
          ],
          "own_description": "Consoles Accessories; MI-110",
          "full_description": "LOOSE FURNITURE — Console — Consoles Accessories; MI-110",
          "quantity": 47,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 70500,
          "amount_state": "number",
          "source": {
            "sheet": "4.1-M",
            "row": 16
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.1-M/1-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Console"
          ],
          "own_description": "Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "full_description": "LOOSE FURNITURE — Console — Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "quantity": 47,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 70500,
          "amount_state": "number",
          "source": {
            "sheet": "4.1-M",
            "row": 18
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.1-M/1-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Curtains",
            "Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories"
          ],
          "own_description": "To apartments",
          "full_description": "LOOSE FURNITURE — Curtains — Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories — To apartments",
          "quantity": 3465,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 433125,
          "amount_state": "number",
          "source": {
            "sheet": "4.1-M",
            "row": 24
          },
          "extra_columns": {
            "User3 [H]": "6.1"
          }
        }
      ]
    },
    {
      "page_ref": "4.1-M/2",
      "section": "GENERALLY",
      "sheet": "4.1-M",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "4.1-M/2-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "full_description": "GENERALLY — Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "4.1-M",
            "row": 52
          }
        }
      ]
    },
    {
      "page_ref": "4.2-M/1",
      "section": "LOOSE FURNITURE",
      "sheet": "4.2-M",
      "source_collection_aed": 2053750,
      "section_notes": [],
      "items": [
        {
          "id": "4.2-M/1-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-111; 900x1100mm sized; in typical corridors infront of lift lobby above console",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-111; 900x1100mm sized; in typical corridors infront of lift lobby above console",
          "quantity": 62,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 310000,
          "amount_state": "number",
          "source": {
            "sheet": "4.2-M",
            "row": 10
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.2-M/1-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-112; 900x1100mm sized; in typical corridors",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-112; 900x1100mm sized; in typical corridors",
          "quantity": 210,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 1050000,
          "amount_state": "number",
          "source": {
            "sheet": "4.2-M",
            "row": 12
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.2-M/1-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Consoles Accessories; MI-110",
          "full_description": "LOOSE FURNITURE — Casegoods — Consoles Accessories; MI-110",
          "quantity": 56,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 84000,
          "amount_state": "number",
          "source": {
            "sheet": "4.2-M",
            "row": 16
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.2-M/1-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "full_description": "LOOSE FURNITURE — Casegoods — Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "quantity": 56,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 84000,
          "amount_state": "number",
          "source": {
            "sheet": "4.2-M",
            "row": 18
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.2-M/1-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Curtains",
            "Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories"
          ],
          "own_description": "To apartments",
          "full_description": "LOOSE FURNITURE — Curtains — Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories — To apartments",
          "quantity": 4206,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 525750,
          "amount_state": "number",
          "source": {
            "sheet": "4.2-M",
            "row": 24
          },
          "extra_columns": {
            "User3 [H]": "6.1"
          }
        }
      ]
    },
    {
      "page_ref": "4.2-M/2",
      "section": "GENERALLY",
      "sheet": "4.2-M",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "4.2-M/2-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "full_description": "GENERALLY — Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "4.2-M",
            "row": 52
          }
        }
      ]
    },
    {
      "page_ref": "4.3-M/1",
      "section": "LOOSE FURNITURE",
      "sheet": "4.3-M",
      "source_collection_aed": 1835125,
      "section_notes": [],
      "items": [
        {
          "id": "4.3-M/1-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-111; 900 x 1100mm sized; in typical corridors infront of lift lobby above console",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-111; 900 x 1100mm sized; in typical corridors infront of lift lobby above console",
          "quantity": 55,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 275000,
          "amount_state": "number",
          "source": {
            "sheet": "4.3-M",
            "row": 10
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.3-M/1-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-112; 900x1100mm sized; in typical corridors",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-112; 900x1100mm sized; in typical corridors",
          "quantity": 188,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 940000,
          "amount_state": "number",
          "source": {
            "sheet": "4.3-M",
            "row": 12
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.3-M/1-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Consoles Accessories; MI-110",
          "full_description": "LOOSE FURNITURE — Casegoods — Consoles Accessories; MI-110",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 73500,
          "amount_state": "number",
          "source": {
            "sheet": "4.3-M",
            "row": 16
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.3-M/1-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "full_description": "LOOSE FURNITURE — Casegoods — Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "quantity": 49,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 73500,
          "amount_state": "number",
          "source": {
            "sheet": "4.3-M",
            "row": 18
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.3-M/1-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Curtains",
            "Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories"
          ],
          "own_description": "To apartments",
          "full_description": "LOOSE FURNITURE — Curtains — Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories — To apartments",
          "quantity": 3785,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 473125,
          "amount_state": "number",
          "source": {
            "sheet": "4.3-M",
            "row": 24
          },
          "extra_columns": {
            "User3 [H]": "6.1"
          }
        }
      ]
    },
    {
      "page_ref": "4.3-M/2",
      "section": "GENERALLY",
      "sheet": "4.3-M",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "4.3-M/2-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "full_description": "GENERALLY — Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "4.3-M",
            "row": 52
          }
        }
      ]
    },
    {
      "page_ref": "4.4-M/1",
      "section": "LOOSE FURNITURE",
      "sheet": "4.4-M",
      "source_collection_aed": 1896250,
      "section_notes": [],
      "items": [
        {
          "id": "4.4-M/1-A",
          "item_code": "A",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-111; 900x1100mm sized; in typical corridors infront of lift lobby above console",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-111; 900x1100mm sized; in typical corridors infront of lift lobby above console",
          "quantity": 58,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 290000,
          "amount_state": "number",
          "source": {
            "sheet": "4.4-M",
            "row": 10
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.4-M/1-B",
          "item_code": "B",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Artworks"
          ],
          "own_description": "Art works; MI-112; 900x1100mm sized; in typical corridors",
          "full_description": "LOOSE FURNITURE — Artworks — Art works; MI-112; 900x1100mm sized; in typical corridors",
          "quantity": 194,
          "unit": "Nr.",
          "rate_aed": 5000,
          "amount_aed": 970000,
          "amount_state": "number",
          "source": {
            "sheet": "4.4-M",
            "row": 12
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.4-M/1-C",
          "item_code": "C",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Consoles Accessories; MI-110",
          "full_description": "LOOSE FURNITURE — Casegoods — Consoles Accessories; MI-110",
          "quantity": 52,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 78000,
          "amount_state": "number",
          "source": {
            "sheet": "4.4-M",
            "row": 16
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.4-M/1-D",
          "item_code": "D",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Casegoods"
          ],
          "own_description": "Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "full_description": "LOOSE FURNITURE — Casegoods — Console; CG-108; 1670mm(L) x 360mm(W) x 800mm(H) sized",
          "quantity": 52,
          "unit": "Nr.",
          "rate_aed": 1500,
          "amount_aed": 78000,
          "amount_state": "number",
          "source": {
            "sheet": "4.4-M",
            "row": 18
          },
          "extra_columns": {
            "User3 [H]": "6.2"
          }
        },
        {
          "id": "4.4-M/1-E",
          "item_code": "E",
          "section": "LOOSE FURNITURE",
          "heading_path": [
            "Curtains",
            "Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories"
          ],
          "own_description": "To apartments",
          "full_description": "LOOSE FURNITURE — Curtains — Curtain track; comprising galvanized steel rail with powder coated finish; including all necessary fittings, fixings and accessories — To apartments",
          "quantity": 3842,
          "unit": "m",
          "rate_aed": 125,
          "amount_aed": 480250,
          "amount_state": "number",
          "source": {
            "sheet": "4.4-M",
            "row": 24
          },
          "extra_columns": {
            "User3 [H]": "6.1"
          }
        }
      ]
    },
    {
      "page_ref": "4.4-M/2",
      "section": "GENERALLY",
      "sheet": "4.4-M",
      "source_collection_aed": 0,
      "section_notes": [],
      "items": [
        {
          "id": "4.4-M/2-A",
          "item_code": "A",
          "section": "GENERALLY",
          "heading_path": [],
          "own_description": "Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "full_description": "GENERALLY — Allow for any other works which are not included above and which are required to complete the furnishings in accordance with the Specification and the Drawings (Tenderer to list below)",
          "quantity": null,
          "unit": "Item",
          "rate_aed": null,
          "amount_aed": 0,
          "is_lump_sum": true,
          "amount_state": "empty",
          "source": {
            "sheet": "4.4-M",
            "row": 52
          }
        }
      ]
    }
  ]
}